Configuration Guide - Video Intercom Network Indoor Station
Configuration Guide - Video Intercom Network Indoor Station
Configuration Guide
Network Indoor Station Configuration Guide
Legal Information
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
Trademarks
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL
AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND
FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”.
HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR
FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS
AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR
ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES,
INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS,
BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR
LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT,
TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN
i
Network Indoor Station Configuration Guide
Data Protection
During the use of device, personal data will be collected, stored and
processed. To protect data, the development of Hikvision devices
incorporates privacy by design principles. For example, for device with facial
recognition features, biometrics data is stored in your device with
encryption method; for fingerprint device, only fingerprint template will be
saved, which is impossible to reconstruct a fingerprint image.
As data controller, you are advised to collect, store, process and transfer
data in accordance with the applicable data protection laws and regulations,
including without limitation, conducting security controls to safeguard
personal data, such as, implementing reasonable administrative and
physical security controls, conduct periodic reviews and assessments of the
effectiveness of your security controls.
ii
Network Indoor Station Configuration Guide
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Description
iii
Network Indoor Station Configuration Guide
Safety Instruction
Warning
• The working temperature of the device is from -10 ºC to 55 ºC.
• All the electronic operation should be strictly compliance with the electrical
safety regulations, fire prevention regulations and other related regulations in
your local region.
• Please use the power adapter, which is provided by normal company. The power
consumption cannot be less than the required value.
• Do not connect several devices to one power adapter as adapter overload may
cause over-heat or fire hazard.
• Please make sure that the power has been disconnected before you wire, install
or dismantle the device.
• When the product is installed on wall or ceiling, the device shall be firmly fixed.
• If smoke, odors or noise rise from the device, turn off the power at once and
unplug the power cable, and then please contact the service center.
• If the product does not work properly, please contact your dealer or the nearest
service center. Never attempt to disassemble the device yourself. (We shall not
assume any responsibility for problems caused by unauthorized repair or
maintenance.)
Caution
• Do not drop the device or subject it to physical shock, and do not expose it to
high electromagnetism radiation. Avoid the equipment installation on vibrations
surface or places subject to shock (ignorance can cause equipment damage).
• Do not place the device in extremely hot (refer to the specification of the device
for the detailed operating temperature), cold, dusty or damp locations, and do
not expose it to high electromagnetic radiation.
• The device cover for indoor use shall be kept from rain and moisture.
• Exposing the equipment to direct sun light, low ventilation or heat source such
as heater or radiator is forbidden (ignorance can cause fire danger).
• Do not aim the device at the sun or extra bright places. A blooming or smear
may occur otherwise (which is not a malfunction however), and affecting the
endurance of sensor at the same time.
iv
Network Indoor Station Configuration Guide
• Please use the provided glove when open up the device cover, avoid direct
contact with the device cover, because the acidic sweat of the fingers may erode
the surface coating of the device cover.
• Please use a soft and dry cloth when clean inside and outside surfaces of the
device cover, do not use alkaline detergents.
• Please keep all wrappers after unpack them for future use. In case of any failure
occurred, you need to return the device to the factory with the original wrapper.
Transportation without the original wrapper may result in damage on the device
and lead to additional costs.
• Improper use or replacement of the battery may result in hazard of explosion.
Replace with the same or equivalent type only. Dispose of used batteries
according to the instructions provided by the battery manufacturer.
• Input voltage should meet both the SELV and the Limited Power Source
according to 60950-1 standard.
• The power supply must conform to LPS. The recommended adaptor models and
manufacturers are shown as below. Use the attached adapter, and do not
change the adaptor randomly.
Model Manufacturer Standard
ADS-24S-12 1224GPCN SHENZHEN HONOR CEE
ELECTRONIC CO.,LTD
G0549-240-050 SHENZHEN GOSPELL DIGITAL CEE
TECHNOLOGY CO.,LTD
TS-A018-120015Ec SHENZHEN TRANSIN CEE
TECHNOLOGIES CO., LTD
v
Network Indoor Station Configuration Guide
Regulatory Information
FCC Information
Please take attention that changes or modification not expressly approved
by the party responsible for compliance could void the user's authority to
operate the equipment.
FCC compliance: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help
This equipment should be installed and operated with a minimum distance
20cm between the radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference
that may cause undesired operation.
vi
Network Indoor Station Configuration Guide
EU Conformity Statement
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the EMC Directive
2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/
65/EU
vii
Network Indoor Station Configuration Guide
viii
Network Indoor Station Configuration Guide
Contents
1 About this Manual ...................................................................................... 1
2 Local Operation .......................................................................................... 2
2.1 Activate Indoor Station ..................................................................................... 2
ix
Network Indoor Station Configuration Guide
x
Network Indoor Station Configuration Guide
Product Model
1
Network Indoor Station Configuration Guide
2 Local Operation
2
Network Indoor Station Configuration Guide
Steps
1. Choose Language and tap Next.
2. Set network parameters and tap Next
- Edit IP Address, Subnet Mask and Gateway.
- Enable DHCP, the device will get network parameters automatically.
3
Network Indoor Station Configuration Guide
4
Network Indoor Station Configuration Guide
5
Network Indoor Station Configuration Guide
Steps
Note
The default IP address of the indoor station is 192.0.0.64.
Two ways are available for you to set IP address: DHCP, and set IP address manually.
1. Tap Settings → → to enter the network settings page.
Note
Enter activate password as the admin password.
6
Network Indoor Station Configuration Guide
Steps
Note
Here take door station network settings as example.
1. Tap Settings → → to enter the device management page.
Note
Default admin password is the activation password.
7
Network Indoor Station Configuration Guide
Note
Default admin password is the activation password.
8
Network Indoor Station Configuration Guide
Zone Settings
You can set the zone type, alarm type and delay time and other parameters of 8
zones.
9
Network Indoor Station Configuration Guide
Set the alarm type as delay alarm, and you should set the entering delay
duration and exiting delay duration.
• Both the entering delay duration and the exiting delay duration are from 30s
to 60s.
• For Gas Detector and Smoke Detector, the alarm type is set as default 24h
alarm. The alarm type of them can not be changed.
10
Network Indoor Station Configuration Guide
Note
• Zones are configurable on the arming mode page.
• 24H alarm zone including smoke detector zone and gas detector zone will be
triggered even if they are disabled.
• Arming mode settings should be configured with the settings of arming
status on the user page of the device.
11
Network Indoor Station Configuration Guide
Arm or disarm the zone for the indoor station by entering the arm/disarm
password.
Note
Arm/Disarm settings page is hidden by default. Tap Settings → →
Preference to enable Alarm function, you can edit the alarm parameters.
Duress Code
When you are hijacked and forced to open the door, you can enter the
duress code. An alarm will be triggered to notify the management center
secretly.
Note
The duress code and the unlock password cannot be the same.
12
Network Indoor Station Configuration Guide
13
Network Indoor Station Configuration Guide
14
Network Indoor Station Configuration Guide
Time Settings
Clean Screen
Enable the clean screen function and the screen will be locked for 30 s. In
the time duration, you can clean the screen surface. Hold the disable icon or
wait for 30 s to end the status.
15
Network Indoor Station Configuration Guide
Language
16
Network Indoor Station Configuration Guide
17
Network Indoor Station Configuration Guide
Device management includes device activation, adding device, editing device, and
deleting device, and so on.
After running the iVMS-4200, video intercom devices should be added to the client
software for remote configuration and management.
18
Network Indoor Station Configuration Guide
19
Network Indoor Station Configuration Guide
6. Optional: You can check the checkbox Export to Group to create a group by the
device name. All the channels of the device will be imported to the
corresponding group by default.
The client also provides a method to add the offline devices. Check the checkbox
Add Offline Device, input the required information and the device channel
number and alarm input number, and then click Add. When the offline device
comes online, the software will connect it automatically.
Note
• Add Multiple Online Devices: If you want to add multiple online devices to
the client software, click and hold Ctrl key to select multiple devices, and
click Add to Client to open the device adding dialog box. In the pop-up
message box, enter the user name and password for the devices to be
added.
• Add All the Online Devices: If you want to add all the online devices to the
client software, click Add All and click OK in the pop-up message box. Then
enter the user name and password for the devices to be added.
Select the device from the device list, click , and then you can modify the network
information of the selected device.
Note
You should enter the admin password of the device in the Password field of the pop-
up window to modify the parameters.
20
Network Indoor Station Configuration Guide
3.4.1 System
Click System on the remote configuration page to display the device information:
Device Information, General, Time, System Maintenance, User, and RS-485.
21
Network Indoor Station Configuration Guide
Device Information
Click Device Information to enter device basic information page. You can
view basic information (the device type, and serial No.), and version
information of the device.
General
Click General to enter device general parameters settings page. You can
view and edit the device name and device ID.
Time
Click Time to enter the device time settings page.
22
Network Indoor Station Configuration Guide
System Maintenance
Click System Maintenance to enter the page.
23
Network Indoor Station Configuration Guide
• Click Import Configuration File and the import file window pops up.
Select the path of remote configuration files. Click Open to import the
remote configuration file. The configuration file is imported and the
device will reboot automatically.
• Click Export Configuration File and the export file window pops up.
Select the saving path of remote configuration files and click Save to
export the configuration file.
24
Network Indoor Station Configuration Guide
• Click ... to select the upgrade file and click Upgrade to remote upgrade
the device. The process of remote upgrade will be displayed in the
process bar.
• Select a language, and click Save to change the device system language.
Note
• The device supports 11 languages: English, Russian, German, Italian,
French, Portuguese, Spanish, Turkish, Arabic, Polish, and Vietnamese.
• Rebooting the device is required after you change the system language.
User
Click User to enter the user information editing page.
Select the user to edit and click Modify to enter the user parameter page.
25
Network Indoor Station Configuration Guide
RS-485
Click RS485 to enter the RS-485 settings page. You can view and edit the
RS-485 parameters of the device.
Device ID Configuration
Steps
1. Click ID Configuration to enter device ID configuration page.
26
Network Indoor Station Configuration Guide
Time Parameters
Steps
1. Click Time Parameters to enter time parameters settings page.
27
Network Indoor Station Configuration Guide
• Call forwarding time refers to the ring duration limit beyond which the call is
automatically forwarded to the mobile phone designated by the resident.
The range of call forwarding time varies from 0s to 20s.
• For indoor extension, it only requires setting the maximum live view time.
Permission Password
Click Permission Password to enter password changing page.
Zone Alarm
Steps
1. Click Zone Alarm to enter the zone settings page.
28
Network Indoor Station Configuration Guide
IP Camera Information
You can add, delete and modify cameras that can be added to the video intercom
products, with two ways of getting stream: direct or URL. By exporting and importing
the added device information, you can edit added devices parameters in batch.
29
Network Indoor Station Configuration Guide
Add Camera
Steps
1. Click IP Camera Information to enter IP camera information page.
30
Network Indoor Station Configuration Guide
Deploy Info
Click Deploy Info, you can get the deploy informations.
31
Network Indoor Station Configuration Guide
3.4.3 Network
32
Network Indoor Station Configuration Guide
LAN. The devices can be linked to the door station and realize the linkage between
these devices.
Steps
1. Click Linked Network Configuration to enter linked network configuration page.
33
Network Indoor Station Configuration Guide
34
Network Indoor Station Configuration Guide
• After adding management center IP Address, the events can be uploaded to
the management center.
• For indoor extension, only parameter about the main indoor station should
be configured.
35
Network Indoor Station Configuration Guide
On the main page of the Client Software, click Person to enter the configuration
page.
Add Organization
Steps
1. In the organization list on the left, click +Add.
2. Input the organization name as desired.
3. You can add multiple levels of organizations according to the actual needs.
1) You can add multiple levels of organizations according to the actual needs.
2) Then the added organization will be the sub-organization of the upper-level
organization.
Note
Up to 10 levels of organizations can be created.
You can select the added organization and click to modify its name.
You can select an organization, and click X button to delete it.
Note
• The lower-level organizations will be deleted as well if you delete an
organization.
• Make sure there is no person added under the organization, or the organization
cannot be deleted.
36
Network Indoor Station Configuration Guide
Add Person
Person information is necessary for the video intercom system. And when you set
linked device for the person, the intercom between intercom devices can be realized.
Steps
1. Select an organization in the organization list and click +Add on the person panel
to pop up the adding person dialog.
Note
The Person ID will be generated automatically and is editable.
37
Network Indoor Station Configuration Guide
6) Click Add.
38
Network Indoor Station Configuration Guide
4. Click to select the device and then click Get to start getting the person
information from the device.
Note
• The person information, including person details, person's fingerprint
information (if configured), and the linked card (if configured), will be
imported to the selected organization.
• If the person name stored in the device is empty, the person name will be
filled with the issued card No. after importing to the client.
• The gender of the persons will be Male by default.
39
Network Indoor Station Configuration Guide
Communication Matrix
Scan the following QR code to get the device communication matrix.
Note that the matrix contains all communication ports of Hikvision access
control and video intercom devices.
Device Command
Scan the following QR code to get the device common serial port
commands.
Note that the command list contains all commonly used serial ports
commands for all Hikvision access control and video intercom devices.
40
UD20151B