0% found this document useful (0 votes)
88 views

08GPCat SinglePhaseDC

This document provides information on DC drive products from Control Techniques, including the Fincor and Mentor II/Quantum III series. The Fincor series includes analog chassis and enclosed drives from 1/12 to 5 HP for 115-230V applications. The Mentor II is a digital regenerative or non-regenerative drive from 5HP to 1000HP for 208-660V, while the Quantum III is similar but also includes contactors and fuses for North American customers. Both provide flexible control options.

Uploaded by

SAMO SAMARA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views

08GPCat SinglePhaseDC

This document provides information on DC drive products from Control Techniques, including the Fincor and Mentor II/Quantum III series. The Fincor series includes analog chassis and enclosed drives from 1/12 to 5 HP for 115-230V applications. The Mentor II is a digital regenerative or non-regenerative drive from 5HP to 1000HP for 208-660V, while the Quantum III is similar but also includes contactors and fuses for North American customers. Both provide flexible control options.

Uploaded by

SAMO SAMARA
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 22

www.emersonct.

com

800-893-2321

DC Drives
Rugged dependability and exceptional value
Control Techniques offers two DC drive series that
enable customers to deploy productive, easy-to-use
motor control solutions:
Fincor Series
The Fincor Series is our most flexible line of analog drives,
from the ultra compact Series 2100 chassis drive to the
highly capable Series 2230 in NEMA 4/12 enclosure. Both
regenerative and non-regenerative drives are available in
numerous configurations such as chassis, book case, and
NEMA 4/12. Fincor drives can be easily tailored to your
specific application needs. The drives can be equipped
with or without operator controls, contactor-less control,

DC Drives
armature contactor reversing & dynamic braking, and
more.
Mentor II / Quantum III
O Dual-turret winding
Mentor II is a reliable, flexible and powerful digital DC O Plastic and Rubber Extrusion
drive that is available both in non-regenerative and O Cranes, Hoists, and Cabling
regenerative configurations. It accepts a wide range of
supply voltage from 208 to 480 VAC. Mentor II drives O Iron, Steel and Glassworks
rated at 525/660 VAC ratings may be special ordered. O Tilt Vessels, Coilers, Spoolers
O Metal Fabrication and Wire drawing
Its high-performance characteristics, fast coprocessors,
dual encoder inputs, application and communications Quantum III is a modified Mentor II offered in the same
modules, and high-speed drive-to-drive communications footprint by adding a DC loop contactor, high-speed
capability place it in many applications requiring powerful input fuses and 115VAC control logic, provision to accept
motor control and coordination. AC/DC tachometer feedback and DC output fuse on all
regenerative models. It saves engineering time and panel
O Printing Presses space that makes it ideal for North American customers.
O Heavy Moveable Structures The Mentor II /Quantum III DC drives are also available as
O Lumber and Paper Milling packaged control solutions and in system configurations.
O Paper Converting For details see the Packaged Drives section.

Fincor Series
115V
230V

Mentor II / Quantum III


230V
460V

85
www.emersonct.com

800-893-2321

DC Drives Product Matrix


Fincor Series
p. 88

Drive Family

Fincor 2230 MKII: Analog, Regen


Fincor 2100: Analog, Non-Regen
Control Technology Fincor 2330 MKII: Analog, Non-Regen
Fincor 2610 MKII: Analog, Non-Regen

Power 1/12 to 3 hp 1/12 to 5 hp

AC Voltage
115V-230V 1Ø 115V-230V 1Ø
50/60Hz ± 10%
DC Drives

Voltage Feedback (CEMF) Voltage Feedback (CEMF)


Motor Feedback
DC Tachometer (2122,2123) and DC Tachometer

2230 2330 2610


Digital In: 1 Digital In: 2 1 2
Input/Output
Analog In: 1 Analog In: 4 2 4
Analog Out: 4 0 4

Input/Output
External Signal Follower N/A
options

Communication N/A N/A

Configuration &
N/A N/A
Programming

Application
N/A N/A
Co-processor

Application
N/A N/A
Software

Chassis:
Power Fuse Block,
Amature Contactor w/DB
Accessories Barrier Terminal
Board

Approvals UL, CUL UL, CUL


86
www.emersonct.com

800-893-2321

Mentor II Quantum III


p. 110 p. 114

Drive Family

Control Technology Digital, Non-Regen, Regen, SCR Digital, Non-Regen, Regen, SCR

Power 5 hp to 1000 hp 5 hp to 1000 hp

AC Voltage 208-240V 3Ø
208-660V 3Ø
50/60Hz ± 10% 380-480V 3Ø

DC Drives
Voltage Feedback (CEMF) Voltage Feedback (CEMF)
Motor Feedback DC Tachometer AC or DC Tachometer
Encoder Encoder

Input Output Input Output


Input/Output Digital 12 7 Digital 9 5
Analog 5 4 Analog 5 4

Input/Output Remote I/O Remote I/O


options I/O Box I/O Box

RS485/232 RS485/232
Communication Cards for Communication Cards for
Communication MODBUS RTU, DeviceNet, MODBUS RTU, DeviceNet,
PROFIBUS DP, INTERBUS-S, PROFIBUS DP, INTERBUS-S,
CTNet with MD29AN CTNet with MD29AN

Configuration &
MentorSoft MentorSoft
Programming

Application MD29 32bit-coprocessor MD29 32bit-coprocessor


Co-processor MD29AN s/a with CTNet MD29AN s/a with CTNet

SyPT Pro IEC61131-3 ladder and


Application SyPT Pro IEC61131-3 ladder and function block
function block programming or DPL
Software programming or DPL (Drive Programming Language)
(Drive Programming Language)

Includes line fuses, motor contactor, and


Power
Optional Field Regulator 120V control logic board as standard.
Accessories
Optional Field Regulator

Approvals UL, CUL, CE, C-Tick, ISO14001, ISO9001:2000 UL, CUL, CE, C-Tick, ISO14001, ISO9001:2000
87
www.emersonct.com

800-334-3040

Fincor DC Drives
Flexible & Powerful
Fincor single-phase DC drives provide a complete family
solution – from the compact Series 2120 chassis drive
to the powerful Series 2230 MKII and it’s feature rich
application specific options.

Fincor drives have earned a reputation for reliability and


extensive features which put them a step ahead of the
competition. These options are standard on MKII drives
and available as noted on other drive series. Some of
these features include:

• Isolated Regulator protects internal control circuits


from the AC power source, operators and equipment.
The control reference input common may be grounded
or connected without additional isolation to additional • Analog DC Drive
drives or grounded external sources. Isolation eliminates • 1/6 to 5 hp (115-230 VAC)
Fincor

the common condition of line voltage to ground potential • Non-regen and Regen models
being present at the operator station potentiometer. • Chassis, Bookshelf, NEMA 1, or NEMA 4/12
• Tachometer or armature feedback
• External DC Signal Follower includes isolation • Complete motor solutions
and impedance matching circuitry to interface an
externally supplied grounded or ungrounded, isolated or
nonisolated 0-5 VDC, 0-10 VDC or 4-20 mA DC signal TYPICAL APPLICATIONS
source, with the motor controller reference input. This
provides a linear transfer of the external signal to motor —Conveyor
speed.
—Rugged
• AC Line Starting (Auto-Restart) simplifies restart —Extruder
control wiring requirements. Also permits run-stop —Reliable
control of unidirectional models by using an external AC
2610

Adjus
Spee table

line contactor. Smooth starting capabilities are included.


Drived
s
MOTOR
SPEED
(%)

RUN

STOP
JOG

• DC Tachometer Feedback provides wider speed


range, improved speed regulation with load changes and
reduced sensitivity to operating conditions such as line
voltage variations, ambient temperature changes, motor
field heating and other operating variables. The controller —Conveyor
2610

Adj

will automatically transfer to counter EMF voltage —Simple


usta
Spe ble
Drived
es
MOTOR
SPEED
(%)

RUN

feedback to prevent run away if the tachometer circuit is


STOP
JOG

disconnected. Tachometers producing 7 to 150 VDC at


maximum motor speed may be used. —Mixer
—Flexible
2610

Ad
jus
Speedtable
Dri
ves
MOTOR
SPEED
(%)

RUN

STOP
JOG
2610

Ad
jus
Speedtable
Dri
ves
MOTO
R SPEED
(%)

1: 200
00
RUN

STOP
JOG
0
ISO 9

AL

AP
P R OV

88 Contact factory for “Operator Stations”


www.emersonct.com

800-334-3040

CHOOSE NON-REGEN OR REGENERATIVE Order String


Non-regenerative drives are used when friction or a
dynamic brake stopping is adequate. A contactor may be 2 x x x x x x
used to achieve reversing operation. Non-regen drives are
less expensive than Regen drives when reversing is not Cover Configuration: 0 = No Controls
required. 1 = Run/Stop/Jog/Speed Pot
2 = Run/Stop/Jog/Fwd/Rev/Speed Pot
3 = Run/Stop/Jog/Fwd/Rev
Regenerative drives include static reversing and are P.B./Speed Pot
7 = Run/Stop/Jog/Manual-Auto
used when you need four quadrant control or Forward Switch/Speed Pot
& Reverse operation from a bidirectional control signal
Basic Configuration: No Letter = Chassis,
(+/- 10 VDC). It will stop the load smoothly and faster P = Enclosed (top cover)
than a dynamic brake for fast stop or emergency stop Armature Contactor: No Letter = None,
requirements and it will regenerate power to the supply A = Armature Contactor Reversing with DB,
B = Unidirectional Armature Contactor with DB
if the load is overhauling (wanting to go faster than the
motor set speed). Current Step
Drive Series Revision Level: i.e. 2 = 2120,
CHOOSE DRIVE SERIES 3 = 2230, 4 = 2240,
1 = Base, 2 = Regen, 3 = Non-Regen,
Now choose the drive series from either Non-regen or 6 = Non-Regen high end
Regen product pages. The chart below compares features 2 = Single Phase Input Drive Basic Model
and horsepower ratings, with the simplest and least
expensive drive at the top and highest horsepower range

Fincor
and flexibility towards the bottom.

Fincor Single Phase DC Selection Chart

Series

2100 Micro Drive / non-isolated


Non-Regenerative

Limited options / speed input

2330 MKII Full Featured / isolated


8 options / speed & torque input

2610 MKII Full Featured / isolated


16 options / speed & torque in/out
Regenerative

2230 MKII Full Featured / isolated


12 options / speed & torque in/out

Horsepower

89
www.emersonct.com

800-334-3040

Fincor Non-Regen Drives


Non-regenerative drives are typically used on applications contact closure to initiate the change. Upon the reversing
which primarily motor in one direction and stopping is signal, the drive will allow the motor to coast to a stop (or
achieved through friction or infrequent use of a dynamic perform a control stop under a decel ramp with control stop
braking resistor. These drives may provide speed or torque option) or utilize a dynamic braking resistor to pull it to a
control from a potentiometer or unidirectional (0-10 VDC stop before switching the motor leads with a contactor and
or 4-20 mA) control signal. Reversing requires a switch or starting the motor in the opposite direction.

Fincor Series 2120


2121 & 2122
2122H
Fincor Series 2100 drives feature compact size and lowest
pricing. Chassis units are dimensionally interchangeable
Fincor 2100

with many competitive units. They are ideal for the


OEM or panel builder who builds a custom system by
integrating the drive into an enclosure with special logic
or auxiliary control devices.

• 1/6 to 3 hp (115 -230V)


• Budget Priced 2123
• Speed Control
• Current Limit
• UL Recognized

RATINGS: 1/12 TO 3 hp (120-240 VAC)


Series 2100 Non-Regenerative DC Drives

Motor Input Output RUN-STOP


Model
HP 2 DC Volts Amps
AC Volts Amps Order Code
Arm Field Arm Field
1/6-1/2 120 8.7 90 50/100 5.4 1.0 2121
1/6-1/2 120 8.7 90 50/100 5.4 1.0
2122
1/2-1.0 240 8.8 180 100/200 5.5 1.0
1 1/6-1.0 120 15 90 50/100 10.5 1.0
Chassis
2122H
1/2-2.0 240 15.8 180 100/200 11.6 1.0
1/6-1.0 120 15 90 50/100 10.5 1.0
2123
1/2-3.0 240 24 180 100/200 16 1.0
(1) Model 2120 units are furnished with a potentiometer rated 5K ohms, 1/2 watt for separate mounting.
(2) Units may be easily recalibrated using trimpots for any standard rating within the hp range.

Option Description Order Code


Knob and Dial Plate Kit — This option provides a knob and a dial face graduated 0-100% for use with the potentiometer provided with
106409401
Series 2120 units.
External Signal Follower/Isolation — For use with isolated or nonisolated 4-20 ma DC, 0-10 VDC signals. Includes a scaling potentiometer
2067109
for offset adjustment. Dimensions 1.5” (38) X 3.38” (86) X .75” (19).

90
www.emersonct.com

800-334-3040

Fincor Series 2120 DIMENSIONS


2121 & 2122 Weight (Chassis)
.5 lb. .23 kg

SPECIFICATIONS: Chassis 1.64”


(42 mm)

Operating Conditions
Horsepower 1/6 thru 3 hp , Trim Pot Selectable
Line Voltage 115-230VAC ±10%, Bi Voltage Input
Rated Frequency 50/60Hz ±2%
4.25”
Enclosure Chassis (108 mm)

Ambient Temperature 0 – 55°C (32°F - 131°F)


Altitude 1000m (3,300 ft)
Relative Humidity 95% Non condensing
Overload Capacity 150% for 1 minute
(UL Listed Motor Overload Protection)
(120% Timing Threshold) 3.55”
(90 mm)
Weight (Chassis)
.5 lb. .23 kg

Standard Features ?.??”


(?? mm)

Regulator Function Speed Regulated


Power Conversion 2 SCR plus Freewheeling Diode
Field Supply Full Wave 2122H

Fincor 2100
Protection MOV Voltage Transient Suppression Chassis
High Interrupting Capacity Line Fuse
Speed Regulation Armature or DC Tach Feedback

Control 4.25”

Control Logic Power Common for Maintained Switch (108 mm)

Speed Potentiometer 5K Ohms, ½ Watt


Input Reference 0 – 10Vdc
Speed Regulation 2% with Armature Feedback
(95% Load Change) 1% with Tachometer Feedback

3.55”
Adjustments (90 mm)

Weight (Chassis)
Maximum Speed 60% – 100% of Motor Base Speed 1 lb. .45 kg

Minimum Speed 0% – 40% of Motor Base Speed


2123 1.87”
(48 mm)
Current Limit 0 – 150% of Full Load
IR Compensation 0 – 100% Boost
Chassis
Acceleration/Deceleration 0-4 Seconds

Efficiency
Controller (only) 98%
With Motor (typical) 85%
7”
(178 mm)
Approvals & Listings
UL and cUL

4.25”
(108 mm)

91
www.emersonct.com

800-334-3040

Fincor Series
2330 MKII
Fincor Series 2330 MKII drives features a fully isolated
regulator using surface mount technology. It includes
an isolated customer run contact, low voltage operator
control circuitry, and full wave power conversion.
Book Case

• 1/6 to 5 hp (115-230V)
• Fully Isolated Regulator
• Speed or Torque Control Enclosed
• 0-10 VDC or 4-20 mA input signal
• Fused Input
• Line Start (Auto Restart)
• Dual Field Supply
• Tachometer Input standard
Fincor 2330

Open Chassis

RATINGS: 1/6 TO 5 hp (115-230 VAC)


Series 2330 MKII Non-Regenerative DC Drives
Run-Stop,
Run-Stop, Run-Stop, Arm.
Input Output Arm. Cont.
(Basic) Cont., Rev. & DB
Motor DB
Model
HP
DC Volts Amps
AC Volts Amps Order Code Order Code Order Code
Arm Field Arm Field

1/6-1.0 120 15.8 90 50/100 10.5 1.0


2331 2331B 2331A
Chassis 1/2-2.0 240 15.8 180 100/200 11.6 1.0
w/o Operator
Controls 1/6-1.0 120 15.8 90 50/100 10.5 1.0
2332 2332B 2332A
1/2-3.0 240 22 180 100/200 15.1 1.0
1/6-1.0 120 15.8 90 50/100 10.5 1.0
2335 2235B 2235A
Book Case 1/2-2.0 240 15.8 180 100/200 11.6 1.0
w/o Operator
Controls 1/6-1.0 120 15.8 90 50/100 10.5 1.0
2336 2336B 2336A
1/2-3.0 240 22 180 100/200 15.1 1.0

NEMA 4/12 w/o 1/6-1.0 120 15.8 90 50/100 10.5 1.0


2331P0 2331BP0 2331AP0
Operator Controls 1/2-2.0 240 15.8 180 100/200 11.6 1.0
1/6-1.0 120 15.8 90 50/100 10.5 1.0
2331P1* 2331BP1* 2331AP3
NEMA 4/12 with 1/2-2.0 240 15.8 180 100/200 11.6 1.0
Integral Operator
Controls 1/6-1.0 120 15.8 90 50/100 10.5 1.0
2331P2*
1/2-2.0 240 15.8 180 100/200 11.6 1.0

Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230VAC but may be reconnected for 115VAC.

* P1, BP1, & P2 have additional Jog controls. 2331P2 includes switch reversing (not contactor) without DB.

92
www.emersonct.com

800-334-3040

Fincor Series 2330 MKII DIMENSIONS


SPECIFICATIONS:
2330 MKII
Operating Conditions Weight (Enclosed)

Horsepower 1/6 thru 3 hp, Jumper Selectable


3 lbs. 1.56 kg
Enclosed
Line Voltage 115-230VAC ±10%, 5”
Jumper Selectable (127 mm)

Rated Frequency 50/60Hz ±2%


Enclosure Chassis, Bookcase, NEMA 4/12
Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)
0 – 55°C (32°F - 131°F) (Chassis)
Altitude 1000m (3,300 ft)
Relative Humidity 95% Non condensing

2330
Ad
ju
Spe stabl
Overload Capacity 150% for 1 minute Dri e d
e
ves
(UL Listed Motor Overload Protection)
(120% Timing Threshold) MO
TO
RS
PE
E D (%
)

9.5”
(231 mm)
Standard Features
FW

Isolated Regulator Circuit Grounded I/O signals possible


D

Fincor 2330
RE
V

Regulator Function Speed or Torque selectable RU


N

Power Conversion 4 SCR plus Freewheeling Diode JO


G
STO
P

Field Supply Full or Half Wave


Protection MOV Voltage Transient Suppression
High Interrupting Capacity Line Fuse
5.25”
Speed Regulation Armature or DC Tach Feedback (133 mm)

Line Start Selectable for Auto Restart


Diagnostic LED Green Normal – Red Current Limit
Option Connector Connects Additional Option Boards

Control
2330 MKII
Weight (Chassis)
3 lbs. 1.36 kg
Control Logic Power 24VDC for Maintained Switch or
Pushbutton Operation 2330 MKII Chassis
Speed Potentiometer 5K Ohms, ½ Watt Bookcase 5”
(127 mm)

Input Reference 0 – 10Vdc or 4 – 20ma Weight (Bookcase)


1 lb. .45 kg
Speed Regulation 2% with Armature Feedback
1.75”
(95% Load Change) 0.5% with Tachometer Feedback (43 mm)

Adjustments
Maximum Speed 50% – 100% of Motor Base Speed
2330

Minimum Speed 0% – 40% of Motor Base Speed


Current Limit 0 – 150% of Full Load
IR Compensation 0 – 100% Boost
Acceleration/Deceleration 0.2-30 Seconds 8.85”
9.5”
(241 mm)
(218 mm)

Efficiency
Controller (only) 98%
With Motor (typical) 85%

Approvals & Listings 4.25”
(108 mm)
UL and cUL
4.25”
(108 mm)

93
www.emersonct.com

800-334-3040

Terminal Diagram: 2330 MKII TB1 TB2

Minimum Speed
Speed Ref Input Speed Ref Pot
+10V Ref
Ext Current Ref Input Torque Ref Pot
Circuit Common
Half
Wave Current Loop Follower Input
4-20ma
Field Tachometer Fdbk Input
Run Enable Input (+24VDC)
+24VDC
Run Relay N.O. Contacts
Motor Armature Run Relay N.O. Contacts
Fincor 2330

Terminal Description

TB1 TB2
Pin# Type Notes Pin# Type Notes
L1 Line Voltage Input 115 or 230VAC J1 Selectable 1 Speed Reference Pot ‘0’ End With On-board Min Speed Pot Active
L2 Line Voltage Input 115 or 230VAC J1 Selectable 2 Speed Reference Input 200KΩ Input Resistance
F+ Field Voltage Output +100VDC @ 115VAC or +200VDC 3 +10V Reference Output 5ma max
@230VAC Input 4 External Current Reference Refer to DIP Switch SW3-
F/2 Field Voltage (Half-Wave) +50VDC @ 115VAC or +100VDC Input FWD
Output @230VAC Input 5 Circuit Common Isolated From Line – Can be connected
F- Field Voltage Output Field Minus Output to Earth
A1 Armature + Output 0 to +90VDC @ 115VAC or 6 Current Loop Follower Input Refer to DIP Switch SW3-2
0 to +180VDC @ 230VAC Input (1-5, 4-20, 5-50ma)
A2 Armature - Output Armature Minus Output 7 Tachometer Input (Speed Polarity Insensitive for Reversing
Feedback) Applications (3-30Vdc, 31-175Vdc)
8 Enable Input (+24VDC) 24VDC @ 6ma Input
– Run Relay
9 +24VDC For drive enable use only
10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115VAC
or 2A @ 30VDC
11 Run Relay N.O. Contacts

94
www.emersonct.com

800-334-3040

Fincor Series
2610 MKII 2610 MKII Enclosed
Fincor Series 2610 MKII drives feature a fully isolated
regulator using surface mount technology. It includes
additional inputs and outputs with advanced control
capabilities.

Fincor 2610 MKII


• 1/12 to 5 hp
• Fully Isolated Regulator
• Speed or Torque Control
• 0-10 VDC or 4-20 mA input signal
• PID / Speed Trim Control
• Monitoring Output (0-10 VDC or 4-20 mA)
• Line Start /Auto Restart Enable/Disable
• Dual Field Supply
• DC-Tachometer Input

Fincor 2600
Open Chassis Book Case
RATINGS: 1/6 TO 5 hp (115-230 VAC)
Series 2600/2610 MKII Non-Regenerative DC Drives
Model Motor Input Output Run-Stop,
Run-Stop, Run-Stop, Arm.
HP Arm. Cont.
(Basic) Cont., Rev. & DB
DB
AC Volts Amps DC Volts Amps Order Code Order Code Order Code
Arm Field Arm Field
1/6-1.0 115 15.8 90 50/100 10.5 1.0
2611 2611B 2611A
1/2-2.0 230 15.8 180 100/200 11.6 1.0
1/6-1.0 115 15.8 90 50/100 10.5 1.0
Chassis 2612 2612B 2612A
1/2-3.0 230 22 180 100/200 15.1 1.5
1/6-1.0 115 15.8 90 50/100 10.5 1.0
2613 2613B 2613A
1/2 -5.0 230 32 180 100/200 25 2.0
1/6-1.0 115 15.8 90 50/100 10.5 1.0
NEMA 4/12 w/o 2611P0 2611BP0 2611AP0
1/2-2.0 230 15.8 180 100/200 11.6 1.0
Integral Operator
Controls 1/6-1.0 115 15.8 90 50/100 10.5 1.0
2613P0 2613BP0 2613AP0
1/2-5.0 230 32 180 100/200 25 2.0
1/6-1.0 115 15.8 90 50/100 10.5 1.0
2611P1* 2611BP1* 2611AP3*
1/2-2.0 230 15.8 180 100/200 10.5 1.0
1/6-1.0 115 15.8 90 50/100 10.5 1.0
2613P1* 2613BP1 2613AP3*
1/2-5.0 230 32 180 100/200 25 2.0
NEMA 4/12 with 1/6-1.0 115 15.8 90 50/100 10.5 1.0
Integral Operator 2611P2*
1/2-2.0 230 15.8 180 100/200 11.6 1.0
Controls
1/6-1.0 115 15.8 90 50/100 10.5 1.0
2611P7 2611BP7
1/2-2.0 230 22 180 100/200 15.1 1.5 Manual / Auto
1/6-1.0 115 15.8 90 50/100 10.5 1.0 Switch.
2613P7 2613BP7
1/2-5.0 230 32 180 100/200 25 2.0

Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230VAC but may be reconnected for 115VAC.

* P1, PB1, AP3, P2 have additional Jog controls. 2611P2 includes switch reversing (not contactor) without DB. 95
www.emersonct.com

800-334-3040

Fincor Series 2610 DIMENSIONS


2613Px Enclosed and
SPECIFICATIONS: 2613 Chassis see page 97
Operating Conditions
Horsepower 1/6 thru 5 hp, Jumper Selectable Weight (Enclosed)

Line Voltage 115-230VAC ±10%, Jumper Selectable 2610 MKII 3.25 lbs. 1.48 kg

Enclosed
Rated Frequency 50/60Hz ±2%
5”
Enclosure Chassis, Bookcase, NEMA 4/12 (127 mm)

Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)


0 – 55°C (32°F - 131°F) (Chassis)
Altitude 1000m (3,300 ft)
Relative Humidity 95% Non condensing
Overload Capacity 150% for 1 minute

2610
Ad
(UL Listed Motor Overload Protection ju
Spe stabl
e
– File # E184521) Dri e d
ves
(120% Timing Threshold) MO
TO
R SP


EE
D (%
)

9.5”
Standard Features (241 mm)

Isolated Regulator Function Grounded I/O signals possible


Fincor 2600

Regulator Function Speed or Torque selectable


RU

Power Conversion 4 SCR plus Freewheeling Diode


N

STO
JO P
G

Field Supply Full or Half Wave


Protection MOV Voltage Transient Suppression
High Interrupting Capacity Line Fuse
Speed Regulation Armature or DC Tach Feedback 5.25”
(133 mm)
Weight (Bookcase)
Line Start Selectable for Auto-Restart 1 lb. .45 kg

Controlled Stop Provides ramp to stop function 1.75”


(43 mm)

Zero Speed Indication Open Collector – Active Low


Speed Regulation Node External PID Input or Speed Trim
Weight (Chassis)
Speed Outputs 0 – 10Vdc and 4 – 20ma 3 lbs. 1.36 kg

Torque Outputs 0 – 10Vdc and 4 – 20ma


Diagnostic LED Green Normal – Red Current Limit 5”
(127 mm)
Option Connector Connects Additional Option Boards

Control 8.85”
(218 mm)

Control Logic Power 24VDC for Maintained Switch or


Pushbutton Operation
Speed Potentiometer 5K Ohms, ½ Watt
Input Reference 0 – 10Vdc or -10 – +10Vdc
2610

Speed Regulation 2% with Armature Feedback


(95% Load Change) 0.5% with Tachometer Feedback
4.25”
(108 mm)
Adjustments 9.5”
(241 mm)
Maximum Speed 50% – 100% of Motor Base Speed
Minimum Speed 50% – 40% of Motor Base Speed 2615 MKII
Current Torque Limit 0% – 150% of Full Load Bookcase
IR Compensation 0 – 10% Boost
Acceleration/Deceleration 0.1 – 30 Seconds
Voltage (Speed) Stability Speed Gain Fine Tune
Current (Torque) Stability Current Gain Fine Tune
4.25”
Efficiency (108 mm)

Controller (only) 98% 2610 MKII


With Motor (typical) 85%
Chassis

Approvals & Listings
96 UL and cUL
www.emersonct.com

800-334-3040

Fincor Series
2610 & 2230
5 hp drive dimensions
The new 5 hp rating in the 2610 non-regenerative series
and the 2230 regenerative series combine industry
leading Fincor electronics with the Control Techniques
Focus series enclosure to achieve more customer value.

Standard features include a fully isolated circuit board


using surface mount technology, speed or torque control,
PID/Speed Trim control, Monitoring Output, and DC Please see the respective 2610 series and 2230 series
Tachometer Input. sections for specifications and more details regarding
these drives..

DIMENSIONS

Fincor 2600
2613 MKII 2613 MKII
2233 MKII 2233 MKII
Enclosed Chassis

AU
TO

MA
N

RE
V
JO
G
FW
D
RU
N STA
RT

STO
P

AU
TO

MA
N

RE
V
JO
G
FW
D
RU
N STA
RT

STO
P

97
www.emersonct.com

800-334-3040

Terminal Diagram: 2600/2610 MKII


TB1 TB2

Min Speed
Speed Ref Input Speed Ref Pot
+10V Ref
Ext Current Ref Input Torque Ref Pot
Current Common
Half
Wave Current Loop Follower Input
4-20ma
Field Tachometer Fdbk Input
Run Enable Input (+24VDC)
+24VDC
Run Relay N.O. Contacts
Motor Armature Run Relay N.O. Contacts
Controlled Stop Input
Zero Speed Output Controlled Stop
Speed Reg Node Input K
Cur. (4 to 20mA) Output Speed
Fincor 2600

Circuit Common
0 to +10VDC Output Speed
Circuit Common
Cur. (4 to 20mA) Output Torque
Circuit Common
0 to +10VDC Output Torque
Circuit Common
Terminal Description

TB1
Pin# Type Notes
L1 Line Voltage Input 115 or 230VAC J1 Selectable TB2 Continued
L2 Line Voltage Input 115 or 230VAC J1 Selectable Pin# Type Notes
F+ Field Voltage Output +100VDC @ 115VAC or +200VDC 8 Enable Input (+24VDC) 24VDC @ 6ma Input
@230VAC Input – Run Relay
F/2 Field Voltage (Half-Wave) +50VDC @ 115VAC or +100VDC 9 +24VDC For drive enable use only
Output @230VAC Input
10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115VAC
F- Field Voltage Output Field Minus Output or 2A @ 30VDC
11 Run Relay N.O. Contacts
A1 Armature + Output 0 to +90VDC @ 115VAC or 0 to
12 Controlled Stop Input Momentary +24VDC Input to Initiate
+180VDC @ 230VAC Input
(+24VDC) Controlled (Ramp) to Stop
A2 Armature - Output Armature Minus Output
13 Zero Speed Indication Output Open Collector, Active Low, Rated
24VDC @ 50ma
TB2
14 Speed Regulator Node Input Speed Trim or External PID Input
Pin# Type Notes
(Bypasses Accel/Decel Ramps)
1 Speed Reference Pot ‘0’ End With On-board Min Speed Pot Active
15 Current Loop Output 4 to 20ma – Speed (Arm Volts)
2 Speed Reference Input 200KΩ Input Resistance
16 Current Loop Output 4 to 20ma – Speed (Arm Volts)
3 +10V Reference Output 5ma max
17 Voltage Output 0 to 10VDC – Speed (Arm Volts)
4 External Current Reference Refer to DIP Switch SW3-2 (1-5, 4-20,
18 Voltage Output Common Isolated From Line – Can be connected
Input 5-50ma)
to Earth
5 Circuit Common Isolated From Line – Can be connected
19 Current Loop Output 4 to 20ma – Torque (Arm
to Earth
Amps)
20 Current Loop
6 Current Loop Follower Input Refer to DIP Switch SW3-2 (1-5, 4-20,
5-50ma) 21 Voltage Output 0 to 10VDC – Load (Arm Amps)
7 Tachometer Input (Speed Polarity Insensitive for Reversing Ap- 22 Voltage Output Common Isolated From Line – Can be connected
Feedback) plications (3-30VDC, 31-175VDC) to Earth
98
www.emersonct.com

800-334-3040

Fincor TYPICAL APPLICATIONS

Regenerative —Material Payoff

DC Drives
—Performance

Regenerative adjustable speed drives also known as


four-quadrant drives, are capable of controlling not only
the speed and direction of motor rotation, but also the
direction of motor torque. This is illustrated below.

The term regenerative describes the ability of the drive


under braking conditions to convert the mechanical
energy of the motor and connected load into electrical
energy which is returned (or regenerated) to the AC
power source.

2610
Ad
jus
Spee table
Drived
s
MOTO
R SPEED
(%)

When the drive is operating in Quadrants I & III, both


RUN

STOP
JOG

motor rotation and torque are in the same direction and


it functions as a conventional non-regenerative drive.

Fincor
The unique characteristics of a regenerative drive are —Conveyor
apparent in Quadrants II & IV. In these quadrants, the
motor torque opposes the direction of motor rotation —Reliable
which provides a controlled braking or retarding force.
A high performance regenerative drive, such as the
Series 2230, is able to switch rapidly from motoring
to braking modes while simultaneously controlling the
QUADRANT II QUADRANT I
direction of motor rotation.
MOTOR ROTATION

TORQUE
NOTE:
QUADRANT III QUADRANT IV
ARROWS
SAME DIRECTION
MOTORING (PULLING)

ARROWS
OPPOSITE DIRECTION
BRAKING (HOLDING)

Regenerative drives provide reversing without the use of


a contactor. This reduces system cost while eliminating
moving parts and greatly improving reversing and
braking performance.

Although the regenerative drive eliminates the


requirement of a contactor for reversing or normal
operational braking, a contactor is used if dynamic
braking is still required. Although regenerative braking
stops the motor and it’s load faster under normal
conditions, a dynamic brake may be required to stop
the motor and it’s connected load in emergency stop
conditions such as drive failure or if the drive enable is
removed before the motor comes to a complete stop.

99
www.emersonct.com

800-334-3040

Fincor Series
2230 MKII
2230 MKII Enclosed
Fincor Series 2230 regenerative drives are ideal for
your more demanding application with ratings up to
5 horsepower. Regenerative drives handle reversing
without contactors and are able to stop faster. They
feature a fully isolated regulator using surface mount
technology.

Fincor Series 2230 MKII


• 1/6 to 5 hp (115-230V)
• Fully Isolated Regulator
• Speed or Torque Control
• 0-10 VDC or +/- 10 VDC input signal
• PID / Speed Trim Control
• Current Stability Adjust
Fincor 2200

• Speed or Current Monitoring


(0-10 VDC or 4-20 mA)
• Fused Input
• Line Start / Auto Restart Enable / Disable
• Dual Field Supply
• DC Tachometer Input
• Diagnostic LED

Open Chassis Book Case

RATINGS: 1/6 TO 5 hp (115-230 VAC)


Series 2200 Regenerative DC Drives
Model Motor Input Output Run-Stop, Run-Stop,
HP Static * DB **
AC Volts Amps DC Volts Amps Order Code Order Code
Arm Field Arm Field
1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
2231 2231B
1/2 - 2.0 240 15.8 180 100/200 11.6 1.0
Chassis w/o Integral 1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
2232 2232B
Operator Controls 1/2 - 3.0 240 22 180 100/200 11.6 1.0
1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
2233 2233B
1/2 - 5.0 240 32 180 100/200 25 2.0
1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
Book Case w/o 2235 2235B
1/2 - 2.0 240 15.8 180 100/200 11.6 1.0
Integral Operator
Controls 1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
2236 2236B
1/2 - 3.0 240 22 180 100/200 15.1 1.0
1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
2231P0 2231BP0
NEMA 4/12 w/o 1/2 - 2.0 240 15.8 180 100/200 11.6 1.0
Operator Controls 1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
2233P0 2233BP0
1/2 - 5.0 240 32 180 100/200 25 2.0
1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
NEMA 4/12 with 2231P1 2231BP1
1/2 - 2.0 240 15.8 180 100/200 11.6 1.0
Integral Operator
Controls 1/6 - 1.0 120 15.8 90 50/100 10.5 1.0
2233P1 2233BP1
1/2 - 5.0 240 32 180 100/200 25 2.0
Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230VAC but may be reconnected for 115VAC.

100 * RUN-STOP, Static, Contactorless Control


** RUN-STOP / DB, Armature Contactor Control & Dynamic Braking
www.emersonct.com

800-334-3040

Fincor Series 2230 MKII DIMENSIONS

2233Px Enclosed and


SPECIFICATIONS: 2233 Chassis see page 97
Operating Conditions
Horsepower 1/6 thru 5 hp, Jumper Selectable
Line Voltage 115-230VAC ±10%, Jumper Selectable Weight (Enclosed)
3 lbs. 1.36 kg
Enclosure Chassis, Bookcase, NEMA 4/12
Rated Frequency 50/60Hz ±2% Selectable 2230 MKII 5”
Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)
Enclosure
(127 mm)

0 – 55°C (32°F - 131°F) (Chassis)


Altitude 1000m (3,300 ft)
Relative Humidity 95% Non condensing
Overload Capacity 150% for 1 minute
(UL Listed Motor Overload Protection
– File # E184521)

2230
Ad
(120% Timing Threshold) ju
Spe stabl
e
Dri e d
ves
Standard Features MO
TO

Isolated Regulator Circuit Grounded I/O signals possible


R SP
EE
D (%
)

9.5”
Regulator Function Speed or Torque selectable (241 mm)

Fincor 2200
Power Conversion 8 SCR Full Wave - Four Quadrant
Field Supply Full Wave
Protection MOV Voltage Transient Suppression RU
N

High Interrupting Capacity Line Fuse JO


G
STO
P

Speed Regulation Armature or DC Tach Feedback


Line Start Selectable for Auto-Restart
Controlled Stop Provides Ramp to Stop Function 5.25”
Zero Speed Deadband Selectable 2% or Off (133 mm)

Zero Speed Indication Open Collector – Active Low Weight (Chassis)


3 lbs. 1.36 kg
Direction Indication Open Collector – Active Low = FWD
Speed Regulator Node External PID Input or Speed Trim 2230 MKII
Speed Outputs -10 – 10Vdc and 4 – 20ma Chassis
5”
(127 mm)
Torque Outputs -10 – 10Vdc and 4 – 20ma
Diagnostic LED Green Normal – Red Current Limit
Option Connector Connects Additional Option Boards
Control
Weight (Bookcase)
Control Logic Power 24VDC for Maintained Switch or 1 lb. .45 kg

Pushbutton Operation
2230

1.75”
Speed Potentiometer 5K Ohms, ½ Watt (43 mm)

Input Reference 0 – 10Vdc or -10 – +10Vdc


Speed Regulation 2% with Armature Feedback
9.5”
(95% Load Change) 0.5% with Tachometer Feedback (241 mm)

Adjustments
Maximum Speed 50% – 100% of Motor Base Speed
Current Limit FWD 0 – 150% of Full Load
Current Limit REV 0 – 150% of Full Load
IR Comp/Tach Scaling 0 – 10% IR or 0 – 100% Tach 8.85”
(218 mm)
Acceleration/Deceleration 0.1 – 30 Seconds
4.25”
Voltage (Speed) Stability Speed Gain Fine Tune (108 mm)

Current Stability FWD Current Gain FWD Fine Tune


Current Stability REV Current Gain REV Fine Tune

Efficiency
Controller (only) 98%
With Motor (typical) 85%
2230 MKII 4.25”

Bookcase
(108 mm)


Approvals & Listings
UL and cUL

101
www.emersonct.com

800-334-3040

Terminal Diagram: 2230 MKII TB1 TB2


Torque Torque
Speed Ref Pot Ref Pot
Ref Pot FWD REV
Circuit Common
Speed Ref Input
+10V Ref
-10V Ref
Ext Current Ref Input FWD
Ext Current Ref Input REV
Tachometer Fdbk Input
Run Enable Input (+24VDC)
+24VDC
Run Relay N.O. Contacts
Run Relay N.O. Contacts
Controlled Stop Input
Zero Speed Output Controlled Stop
Speed Reg Node Input K
Cur. (4 to 20mA) Output Speed
Circuit Common
Fincor 2200

-10 to +10VDC Output Speed


Direction Output K
Cur. (4 to 20mA) Output Torque
Circuit Common
-10 to +10VDC Output Torque
Circuit Common
Terminal Description
TB1
Pin# Type Notes
TB2 Continued
L1 Line Voltage Input 115 or 230VAC J1 Selectable
Pin# Type Notes
L2 Line Voltage Input 115 or 230VAC J1 Selectable
8 Enable Input (+24VDC) 24VDC @ 6ma Input
F+ Field Voltage Output +100VDC @ 115VAC or +200VDC – Run Relay
@230VAC Input
9 +24VDC For drive enable use only
F/2 Field Voltage (Half-Wave) +50VDC @ 115VAC or +100VDC
Output @230VAC Input 10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115VAC
or 2A @ 30VDC
F- Field Voltage Output Field Minus Output 11 Run Relay N.O. Contacts
A1 Armature Output -90 to +90VDC @ 115VAC or -180 to 12 Controlled Stop Input Momentary +24VDC Input to Initiate
+180VDC @ 230VAC Input (+24VDC) Controlled (Ramp) to Stop
A2 Armature Output
13 Zero Speed Indication Output Open Collector, Active Low, Rated
TB2 24VDC @ 50ma
14 Speed Regulator Node Input Speed Trim or External PID Input
Pin# Type Notes
(Bypasses Accel/Decel Ramps)
1 Speed Reference Pot ‘0’ End Speed Pot Common for Uni-Directional
15 Current Loop Output 4 to 20ma – Speed (Arm Volts)
Operation
16 Current Loop Output 4 to 20ma – Speed (Arm Volts)
2 Speed Reference Input 200KΩ Input Resistance
17 Voltage Output -10 to 10VDC – Speed (Arm Volts)
3 +10V Reference Output 5ma max
18 Direction Indicator Output Open Collector, Active Low for FWD;
4 -10V Reference Output 5ma max
Rated 24VDC @ 50ma
5 External Current Reference Refer to DIP Switch SW3-2
19 Current Loop Output 4 to 20ma – Torque (Arm
Input FWD
Amps)
20 Current Loop
6 External Current Reference Refer to DIP Switch SW3-7
Input REV 21 Voltage Output -10 to 10VDC – Load (Arm Amps)
7 Tachometer Input (Speed 3-30VDC, 31-175VDC 22 Voltage Output Common Isolated From Line – Can be connected
Feedback) to Earth

102
www.emersonct.com

800-334-3040

Fincor DC Motors
Permanent Magnet DC Motors
Series 9300
Fincor Series 9300 permanent magnet motors are
industrial rated general purpose DC motors designed
for use with single-phase DC drives. They provide
constant-torque adjustable-speed operation by armature
voltage control to base speed. The motors are suitable
for a wide range of applications including full power
start-stop conditions, continuous high speed operation,
precision speed regulation, regenerative braking and
reversing, low speed contactor reversing, power off
dynamic braking, and crawling duty.
Series 9300 motors feature a permanent magnet field SPEED TORQUE CURVE
with a conventional wound armature and feature 120

Fincor DC Motors
excellent starting torque, speed regulation, dynamic 100
response, and heat dissipation. Series 9300 motors % RATED SPEED
80
should only be plug reversed when reversing currents
60
are limited to less than locked rotor current. D-C N A S
40 Supply

20

0
100 200 300 400 500
% RATED TORQUE (TYPICAL)

Permanent Magnet DC Motors - Series 9300 F500-126

Base Arm Arm Stock Weight


HP Enclosure Frame Order Code
Speed Volts Amps Number (lbs)
1/6 1725 90 2.2 TENV 56C 5009322 9301609TNL 15
1/4 1725 90 2.5 TENV 56C 5009323 9302509TNL 17
1/3 1725 90 3.5 TENV 56C 5009324 9303309TNL 21
90 5 TEFC 56C 5009325 9305009TFL 25
1/2 1725
180 2.5 TEFC 56C 5009326 9305018TFL 25
90 7.3 TEFC 56C 5009327 9307509TFL 32
3/4 1725
180 3.8 TEFC 56C 5009328 9307518TFL 32
90 10.6 TEFC 56C 5009329 9310009TFL 39
1 1725
180 5 TEFC 56C 5009330 9310018TFL 39
1.5 1750 180 7.5 TEFC 145TC 5009331 9315018TFL 68
2 1750 180 9.5 TEFC 145TC 5009332 9320018TFL 73
3 1750 180 12.9 TEFC 182/45TC 5009333 9330018TFL 93
5 1750 180 19.6 TEFC 1810ATC 5008070 9350018TFB 157

Removable Mounting Feet are Included


All items normally stocked

103
www.emersonct.com

800-334-3040

Options for Model TNL, TFL Series 9300 DC Motors


Description Field Installed Factory Installed 1
Order Code Order Code
1/6 to 3/4 hp 106890101
DC Tachometer Generator Type XPY, 50V/1000 RPM with mounting hardware 1 hp 106890102 -5056
182/145TC motor frames 106890103
1/6 to 3/4 hp 106890301
Mounting Hardware Only for XPY or DC Tachometer 1 hp 106890302 -5063A
182/145TC motor frames 106890303
Thermostat -5064A

(1) Factory Installed Options Not Returnable All motors are designed to comply with standard NEMA mounting dimensions, and
manufactured to meet or exceed NEMA electrical and mechanical specifications and
test procedures.
3/8-16
UNC-2B HOLE–
X. 4 EQUALLY
SPACED
MAX. ON A
ENV AG MAX. BD AJ
5.875 D.B.C. 3.12 AH 6.5 O.D. 5.875 D.B.C.
.60 .16 MAX. AA B 2.145/2.095 S
88 DIA. 1.56 BB BF
3/4-14 NPT V .190/.188
Fincor DC Motors

.160 MAX. 3/8-16 UNC-2B (4)


1.41 MIN. 2.0 MIN. .56 DEEP
1.41 ES EQUALLY SPACED
MIN. 1.41 MIN.
KEYWAY 8.06 4.500 FULL KEYWAY AK
NOM. 4.497 4.500/4.497 DIA.
U
45° 6.5 .8750/.8745 DIA.
.6248 3.50 NOM.
.6245 3.47 H D
BA E E 3.50/3.47
.390/.340 *2F .2765/2.735
2.75 N-W A
2.455 DIA. *2F
SEE SHAFT 2.13 7.0 MAX.
3.03* 2.425 4.91 DETAIL B
4.85 6.0 MAX. BC
2.97 .12
2.085 6.50
0 MAX. 2.035 *The optional mounting feet have six
2.56 3/8-16
mounting holes for mounting either the
NOM. UNC-2B HOLE–
143TC or 145TC Frame.
AG MAX. 4 EQUALLY AG MAX. BD
2F: 143TC Frame 4.030/3.970 AH 6.5 O.D. 5.8
RE OPTIONAL. TEFC SPACED
2F: 145TC Frame 5.030/4.970 AA B 2.145/2.095
AG MAX. BB S
ON A 3/4-14 NPT V .190/.188
4.48 TENV 5.875 D.B.C. .160 MAX.
2.68 .16 MAX. 3.12 2.0 MIN.
3.60
1.80 .88 DIA. 1.56 ES E
.61
1.41 MIN.
4.56 1.41 1.41 MIN. FULL KEYWAY
MIN. 4
3.47 KEYWAY 8.06 F500-128U
4.500 .8750/.8745 DIA.
NOM. 4.497
5.13 H BA E
45° 6.5
.390/.340 *2F E 3
NOM. NOM. 2.75 .2765/2.735
.6248 3.50 DIA. *2F N-W A
.6245 3.47 2.13 7.0 MAX.
B
6.0 MAX. BC
.36 2.455 .12
SEE SHAFT
.34 3.03* 2.425 4.91 *The optional mounting feet have six
DETAIL
2.97 4.85 mounting holes for mounting either the
2.085 6.50 143TC or 145TC Frame.
4.00 MAX. 2.035 2F: 143TC Frame 4.030/3.970
2.56 2F: 145TC Frame 5.030/4.970
NOM.
* MOUNTING FEET ARE OPTIONAL.

TNL & TFL Models TFL Models


Model AG Maximum 1 Wt. Model AG Maximum 1 Wt.
HP Enclosure HP Enclosure
Number ªAº ªBº (Lbs.) 2 Number ªBº (Lbs.) 2
1/6 9301609TNL 7.13 – 15 1 1/2 9315018TFL 16.35 68
1/4 9302509TNL 7.66 – 17 TENV 2 9320018TFL 17.35 73 TEFC
1/3 9303309TNL 8.16 – 21 3 9330018TFL 19.75 93
9305009TFL – 9.875
1/2 25
9305018TFL – 9.875
9307509TFL – 12.375
3/4 32 TEFC Notes:
9307518TFL – 12.375
9310009TFL – 14.375 1 To convert dimension figures shown to metric equivalents (mm) multiply by 25.4.
1 39 2 To convert weights shown to metric equivalents (kgs) multiply by 0.45.
104 9310018TFL – 14.375
www.emersonct.com

800-334-3040

Fincor DC Motors
Shunt Wound DC Motors - Series 9200
Fincor Series 9200 motors are industrial rated general
purpose DC motors designed for use with single-phase
DC drives. Series 9200 motors are shunt-wound, or
stabilized shunt-wound and are suitable for constant
torque-adjustable speed operation by armature voltage
control to base speed. The field winding is typically
excited by a separate power supply. With constant
armature voltage and field excitation, a shunt-wound
motor offers relatively flat speed-torque characteristics.

Shunt Wound DC Motors - Series 9200


Base Arm Arm Field Stock Weight
HP Enc Frame Order Code
Speed Volts Amps Volts Number (lbs)
1/6 1750 90 2 50/100 TEFC 56C 5002698 9201609TFB 23

Fincor DC Motors
1/4 1750 90 2.8 50/100 TEFC 56C 5002319 9202509TFB 24
1/3 1750 90 3.5 50/100 TEFC 56C 5002396 9203309TFB 24
90 5.4 50/100 TEFC 56C 5002291 9205009TFB 29
1/2 1750
180 2.6 100/200 TEFC 56C 5002454 9205018TFB 29
90 8.1 50/100 TEFC 56C 5002320 9207509TFB 34
3/4 1750
180 3.8 100/200 TEFC 56C 5002292 9207518TFB 34
90 10.5 50/100 TEFC 56C 5002401 9210009TFB 52
1 1750
180 5.5 100/200 TEFC 56C 5002649 9210018TFB 53
DPG 184C 5002378 9215018DPB 84
1.5 1750 180 8.2 100/200
TEFC 184C 5002648 9215018TFB 84
DPG 184C 5002631 9220018DPB 98
2 1750 180 11.6 100/200
TEFC 184C 5002632 9220018TFB 98
DPG 215C 5002248 9230018DPB 137
3 1750 180 15.1 100/200
TEFC 215C 5002284 9230018TFB 137
DPG 256UC 5002297 9250018DPB 304
5 1750 180 24 100/200
TEFC 256UC 5002296 9250018TFB 304
All items normally stocked

Options for Model TFB & DPB Series 9200 DC Motors


Field Installed Factory Installed 1
Description
Order Code Order Suffix
1/6 to 3/4 hp 106343222
1 hp 106343223
1.5 to 2 hp 106343224
DC Tachometer Generator Type XPY, 50V/1000 RPM with mounting hardware 3 hp DPG 106343225 -B5056
3 hp TEFC 106343226
5 hp DPG 106343227
5 hp TEFC 106343228
1/6 to 3/4 hp 104355801
1 hp 104355809
1.5 to 2 hp 104355808
Mounting Hardware Only for XPY or Fincor DC Tachometer Generator for 3 hp DPG 104355804 -B5063A
3 hp TEFC 104355805
5 hp DPG 104355806
5 hp TEFC 104355807
Thermostats -B5064A

Field Installed items are shipped “loose” for customer mounting


(2) Factory Installed Options Not Returnable
Consult Factory for Availability 105
www.emersonct.com

800-334-3040

SPEED TORQUE CURVE


120
100
% RATED SPEED

SHUNT FIELD
80
D-C A
60 Supply
40
20

0
100 200 300 400 500
% RATED TORQUE (TYPICAL)

LEAD HOLE
C 7/8 DIA.
11/16 AH (184C)
(REF.) AH (215C, 256 UC) 45° 45°
F500-118
KEY BF
AJ
AK O
FP
DIA. U
Fincor DC Motors

D
H = HOLE
BA
F
E E
TBF Models
Frame Model Dimensions, Inches 2
HP
Size 1 Number C D E F H Key O P U AH AJ AK BA BF(tap) FP
1/6 9201609TFB 13.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125
1/4 9202509TFB 13.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125
1/3 9203309TFB 13.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125
9205009TFB 14.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125
F500-121
1/2
56C 9205018TFB 14.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125
9207509TFB 14.75 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125
3/4
9207518TFB 14.75 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125
9210009TFB 16.125 3.5 2.438 3.0 0.406 slot 0.188 7.75 6.625 0.625 2.06 5.875 4.5 2.75 3/8-16 7.188
1
9210018TFB 16.125 3.5 2.438 3.0 0.406 slot 0.188 7.75 6.625 0.625 2.06 5.875 4.5 2.75 3/8-16 7.188

C (TEFC)
C (OPEN) KEY P
AH

° 45°
45

FP
DIA. AK BF
U O

AJ
D

OPEN MOTOR ONLY


VENTS-OPEN
MOTOR ONLY F BA
E E
TBF & DPB Models H = HOLE

Frame Model Dimensions, Inches 2


HP
Size 1 Number C D E F H Key O P U AH AJ AK BA BF(tap) FP
9215018DPB 15.438 4.5 3.75 5.5 0.406 0.188 8.375 7.75 0.875 2.125 5.875 4.5 2.75 3/8-16 –
1-1/2 F500-120
9215018TFB 17.375 4.5 3.75 5.5 0.406 0.188 8.375 7.75 0.875 2.125 5.875 4.5 2.75 3/8-16 8.5
184C
9220018DPB 18.625 4.5 3.75 5.5 0.406 0.188 8.375 7.875 0.875 2.125 5.875 4.5 2.75 3/8-16 8.5
2
9220018TFB 18.625 4.5 3.75 5.5 0.406 0.188 8.375 7.75 0.875 2.125 5.875 4.5 2.75 3/8-16 8.5
9230018DPB 20.938 5.25 4.25 7.0 0.406 0.25 9.938 9.375 1.125 2.75 7.25 8.5 3.5 1/2-13 –
3 215C
9230018TFB 21.188 5.25 4.25 7.0 0.406 0.25 9.938 9.375 1.125 2.75 7.25 8.5 3.5 1/2-13 10.188
9250018DPB 24.75 6.25 5.0 10.0 0.531 0.313 11.938 11.375 1.375 3.50 7.25 8.5 4.25 1/2-13 –
5 256UC
9250018TFB 25.875 6.25 5.0 10.0 0.531 0.313 11.938 11.375 1.375 3.50 7.25 8.5 4.25 1/2-13 12.375
Notes:
106 1 1750 RPM Base Speed only.