Price Bid Electrical Mini RACPCJhalawar Free View

The document is a schedule of unit rate tender for interior furnishing works at an SBI branch in Jhalawar, India. It includes rates for various electrical work items like light points, power points, distribution boards, air conditioning points, and light/fan fixtures. Specifications for approved materials and standards of work are also provided. The schedule contains unit rates for over 50 line items of electrical work.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
47 views

Price Bid Electrical Mini RACPCJhalawar Free View

The document is a schedule of unit rate tender for interior furnishing works at an SBI branch in Jhalawar, India. It includes rates for various electrical work items like light points, power points, distribution boards, air conditioning points, and light/fan fixtures. Specifications for approved materials and standards of work are also provided. The schedule contains unit rates for over 50 line items of electrical work.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Page 1

SBI UNIFORM LAYOUT & COLOUR SCHEME POLICY


SCHEDULE OF UNIT RATE TENDER 2019-20, SBI RACPC JHALAWAR
(A) INTERIOR FURNISHING WORKS
S.No Description Unit Quantity Rate Amount
ELECTRICAL WORK:-
General Notes:-
a) Rates to include all scaffolding, carriage of materials to and from the site in
lead of beyond 5 kms, and working in a running branch premises.
b) Wire Routing provided through the walls / floor / roof etc., rates to include
cutting of wall and refinishing the same finely complete.
c) Points include complete length of wiring, conduiting and accessories upto
designated places as per the design and drawings.
d) Electrical contractor shall have to make the layout for cutting of lights etc. at
site.
e) All newly done electrical wiring/ DB/points/ earthing etc. will be used as per
instructions of architect/ engineer.
1. LIGHT & FAN POINTS:-
P & F light points, fan points, call bell points, sockets etc. with 2 X 1.5
sq. mm. PVC insulated 1100 V grade FRLS, copper conductor wires
and 1.0 sq. mm copper earth wire in concealed / surface using ISI
mark medium guage MS pipes of 25 mm dia 1.50mm thick conduits
accessories such as bends, tees saddles, draw boxes, mounting
boxes, innerplates, cover plates, ceiling rose etc. (where ever
required) and plug etc. The circuit wiring starting from DB to point
control box / switch box using 2 X 2.5 sq. mm and 1.5 sq. mm earthing
PVC insulated wiring color code to be provided. Identification ferrules
at both end to be provided. (Flexible conduit / elbow NOT allowed).
The conduits to be fixed in ceiling with proper clamps / wall / floor and
felling the chase with cement mortar and finish the same in original
form / wooden partition / above false ceiling with proper clamps
(Wherever required as per standard specifications)

SWITCH & SOCKET - NORTH WEST (PC Plus)/ MK (Wrap


around)/Anchor (Wood)/Havells (Crabtree)/ABB(Classic
Luminia)/legrand
Steel Conduit:- AKG/BEC/JINDAL/STEEL KRAFT
Notes:-
All wires shall be FRLS only (Polycab/RR/Finolex/KEI)
All material shall be approved make as mentioned in the tender.

Color codes must be maintained


No flexible conduit & elbows will be allowed.
Each circuit shall have independent earth wire.
Each point must be seperataly earthed.
Circuit wiring is to be included in point wiring rates.
One S.B. can have max. 10-12 switch including 6 Amp. Socket

Boxes fixed in the wooden/ plywood partitions may be PVC


(a) One point controlled by one 6 Amp. Modular switch & switch board at Nos. 30
SB level
(b) Two or more points controlled by one 6 Amp. Modular switch & switch Nos. 50
board at SB level
(c) Wall fan/ Exhaust fan point controlled by one 6 Amp. Modular switch & Nos. 25
switch board at SB level and 6 Amp. 3 pin socket at designed place.

(d) 6 Amp. Socket with switch & light indicator at switch board places. Nos. 15

(e) Call bell point with anchor make Ding Dong Bell Nos. 4
(f) One ceiling fan point controlled by one 6 Amp. Modular switch & Nos. 2
switch board at SB level with 5 step electronic regulator, extension
rods up to 1 meter
(g) Strong room point with metallic switch & socket (Industrial plug) with Nos. 1
25 amps MCB. Rates to include all connections with extension cable
as required on site.
(h) Emergency Light point (On UPS) (Including separate phase, neutral, Nos. 8
earth) and to be in separate switch boards.

2. POWER POINTS :-
Same as item no. 1, including providing & fixing 16 Amp. 6 pin sockets
with 16 amps switch with wiring by using 2x4 sq. mm PVC insulated
copper conductor wire with independent 2.5 sq. mm earth wire from D.
B. to first 1st socket and 1st socket to 2nd socket with 2.5 sq. mm and
1.5 sq. mm earth wire including providing and Fixing complete in all
respects.
(a) Power point (Direct) with 2x 4.0 sq mm copper conductor wires. Nos. 20
(b) Power point (Loop) with 2x 2.5 sq mm copper conductor wires. (Only Nos. 20
one or two loop points are allowed.)

SBI RACPC Jhalawar Electrical


Page 2

SBI UNIFORM LAYOUT & COLOUR SCHEME POLICY


SCHEDULE OF UNIT RATE TENDER 2019-20, SBI RACPC JHALAWAR
(A) INTERIOR FURNISHING WORKS
S.No Description Unit Quantity Rate Amount

3. A. C. POINTS :- C&S/Havells/Legrand/HPL/ABB
(a) A.C. point wiring with 2 X 4.00 sq. mm insulated copper conductor Nos. 6
wire (FRLS) & 1 X 2.5 sq. mm copper conductor wire for earthing from
AC DB to AC point in 16 swg GI conduit AC point including supplying
and fixing of module A.C. Box with 3 Pin metal clad pin top and 25/32
Amp. SP MCB "C" series. (Wiring must be from DB to stablizer to
MCB near indoor unit to Indoor Unit.)

4. DISTRIBUTION BOARDS :-
P & F sheet metal distribution boards of approved make double door
type and making necessary connections etc complete with all MCBs of
C series 10 KA. (LEGRAND/ SCHNEIDER/ SIEMENS/C&S/HPL)

All MCB`S must be 'C' series, 10 KA


T P N 4 WAY DB :- (For Lighting)

Having Incomer : 63 Amp. 4-P MCB


a OUT GOING : 10 Amp. SP MCB - 12 NOS Nos. 2
T P N 4 WAY DB :- (For Power/ AC )
Having Incomer : 63 Amp. 4-P MCB

b OUT GOING : 16 Amp. SP MCB - 12 NOS Nos. 2


c T P N 4 WAY DB :- (For A.C.)
INCOMER: 100 Amp. 4 P, Heavy Duty MCB
S & F 4 way SP MCB 32 Amp MCB - 12 NOS (Out going) Nos. 2

d S P N 12 WAY DB :-
SP MCB 6 Amp = 10 Nos. DP MCB 63 Amp = 1 NOS. Nos. 2

e S P N 4 WAY DB :-
with one number 63 A 4 Pole MCB with enclousure Nos. 5

f S P N 4 WAY DB :-
with two number 63/40 A DP MCB with enclousure Nos. 4

5. LIGHT & FAN FIXTURES :-


P & F light fixture & accessories as per the following details and
making connections, assembling, fixing, testing & installation with 3
years warranty. Following Fixtures including all accessories &
extension chords as maybe necessary complete. All CFL / Flurescent
fixtures (except down lighters) to be hung from the RCC ceiling by
sitable chain / rods) all to fixture rates to include 3 years warranty.
Including all removing, shifting, repairing, fixing, welding, cutting,
instalation, testing, commissioning work of existing or proposed items
for the folowing work. Including making good, proper finish of walls,
floor and roof with masonary, R.C.C., plaster, pop, puty, primer, paint,
etc. complete in all respects. Including color temp. for light fixtures
must be 6500k. Dealer authorisation certificate with invoice detail
required. Technical specification minimum 100 lumens per watt,
Pf>.90, THD<20%

(a) Philips RC 36watt 380B LED Full glow 24" X 24" Nos. 46
(6500K)/BAJAJ/OSRAM/HAVELLS
(b) Philips Green LEDi 15 Watt DN 194 B (6500K) Nos. 80
/BAJAJ/OSRAM/HAVELLS/HPL
(c) Philips LED Tube lights 18 W/ 22 W (6500K) Nos. 5
/BAJAJ/OSRAM/HAVELLS/HPL
(d) Wall fan 400 mm - Crompton High flow of capacitor start, three speed Nos. 16
wall mounting/cabin fan of following sweep with the help of anchor
bolts including making connection testing etc. as required. Each wall
fan should be connected through independent switch and socket of
6Amp.(Crompton/ Almonard/ Usha/ Havells) Only Metal body
Wall mounted 3-pin type fan use

(e) Exhaust fan 300 mm - Crompton/ Almonard of Heavy duty capacitor Nos. 9
start 1400 RPM single phase ISI marked Exhaust fan, IS:2312 marked
including making opening if required, making connections testing etc.
as required.(Crompton/ Almonard/ Usha/ Havells)

SBI RACPC Jhalawar Electrical


Page 3

SBI UNIFORM LAYOUT & COLOUR SCHEME POLICY


SCHEDULE OF UNIT RATE TENDER 2019-20, SBI RACPC JHALAWAR
(A) INTERIOR FURNISHING WORKS
S.No Description Unit Quantity Rate Amount
(f) S& F of Rope Light with driver (Philips/ Bajaj/ HPL/ Osram/ Havells) Rmts. 150

(g) P&F of ceiling Fan Metal body 4800 mm Sweep (Crompton/ USHA/ Nos. 3
Bajaj)

6. CABLES WIRES :-
P & L heavy duty armored cable on saddles wherever exposed and
with aluminium lugs, cable termination with gland, aluminium lugs
properly crimped, etc. complete. Including reusing of the existing
cables wherever required as per direction of Bank Engineer/ Architect,
vendor is bound to execute the items. All existing and proposed cables
to be lay out in existing cable tray. Complete in all respects as per
direction of Bank/ Architect.
XLPE Cable (Polycab/ Finolex/ RR/KEI)
a) 3.50 core X 70 sq. mm Al. armoured cable with 2 X 8 SWG G.I. wire in Rmts. 40
PVC conduit for earthing including cables termination with gland, Al.
lugs properly crimped of required size.
b) 3.50 core X 25 sq. mm Al. armoured cable with 2 X 8 SWG G.I. wire in Rmts. 50
PVC conduit for earthing including cables termination with gland, Al.
lugs properly crimped of required size.
c) 4.00 core X 16 sq. mm Al. armoured cable with 2 X 8 SWG G.I. wire in Rmts. 70
PVC conduit for earthing including cables termination with gland, Al.
lugs properly crimped of required size. (FOR LIGHT, CASSETTE
A.C. & POWER)
d) 4.0 core X 10 sq. mm Copper Armoured cable for UPS to UPS DB Rmts. 40
including cables termination with gland, Al. lugs properly crimped of
required size. (UPS OUTPUT TO UPS DB) & (UPS INPUT TO UPS
DB)

7. U.P.S. POINTS & CIRCUITS :-


P & F ups points in 2 mm thick PVC conduit with 2 X 2.5 sq. mm
insulated copper wire along with 1 X 1.5 sq. mm PVC insulated wire
for earthing including bends, nipples, junction, M.S. switch boxes each
to have 3 nos. 6 A 5 pin modular socket 1 X 6 A indicator controlled by
1 X 16 A modular type switch compl fine finish incl. making necessary
connection & start of equipment as per details. Complete in all
respects as per direction of Engineer/ Architect. Make as specified
above)
(a) DIRECT POINT Nos. 25
(b) LOOP POINT (Only one point to be loop.) Nos. 25

8. EARTHING :- (Ashlok, JK, Ash, REIL)


(a) Supply and installation of pipe-in-pipe technology Copper Earth Nos. 1
Electrode earthing system modelt-39 with outer diameter of 80 mm
length 2000 mm embedded in the soil with masonary inspection pit
along with cover etc. complete in all respect. The work should be got
carried out through bank's authorized Company only. Each pit
installation test certificate to be submitted after measurement of
earth resistances as per the provision in IS 3043 (ups out DB
earthing). The inspection pit should be visible and at a proper
place.
(b) Supply and installation of pipe-in-pipe technology ASHLOK Copper Nos. 1
Earth Electrode earthing system modelt-T19 with outer diameter of
50mm length 2000 mm embedded in the soil with masonary inspection
pit along with cover etc. complete in all respect. The work should be
got carried out through bank's authorized vender only. Each pit
installation test certificate to be submitted after measurement of
earth resistances as per the provision in IS 3043 (Panel ups input
DB earthing).
(c ) P & L 2 X 8 SWg copper earth wire at designated place in PVC Mtrs. 60
conduit (Pit to Panel/ Pit to UPS)
9. MAIN PANEL :-

SBI RACPC Jhalawar Electrical


Page 4

SBI UNIFORM LAYOUT & COLOUR SCHEME POLICY


SCHEDULE OF UNIT RATE TENDER 2019-20, SBI RACPC JHALAWAR
(A) INTERIOR FURNISHING WORKS
S.No Description Unit Quantity Rate Amount
Designing manufacturing, installing, testing and commissioning of Nos. 1
cubical type MAIN PANEL CPRI approved made from 16 SWG CRCA
sheet steel, "type base M.S. channel for grouting on floor complete
with MCCB, MCBs, meters, C.T., etc. complete in all respect,
insulated bus bar with near shrinkable PVC sleeve in suitable bus bar
chamber, wiring, name plates, danger plates, earth bus etc. &
comprising of compartments with hinged doors and rubber gasket, bus
bar chabmer with bolted door and rubber gasket etc. the panel being
of dust & vermin proof construction and to be painted with primer and
smoke gray paint (minimum two coats) to look attractive. The panel
should be comprising with the following : (Degree of Protection IP-54)

INCOMER: -
ALL MCCB SHOULD HAVE 25 KA SHORT CIRCUIT CURRENT
CAPACITY (C- CLASS) (Legrand/ HPL/ C&S/siemens/ABB/
Schneider)
(i) 250 Amp 4 - P, MCCB (3 Phase) 1 Nos.
(ii) 150 Amp 4 - P, ON LOAD change over switch
(iii) 300 Amp. Capacity aluminum bus bar for ATM & system room heat
shrinkable proper insulation with heat shrinkable proper insulation with
color coded. Analog ammeter and voltmeter with selector switches
three number indicating lamp R-Y-B Phase indicators with 2 amp.
back up HRC fuses & Energy Meter with KWH and PF indication
(Back up Fuse protection)
OUT GOING : -
ALL MCCB SHOULD HAVE 25 KA SHORT CIRCUIT CURRENT
CAPACITY
DOUBLE BUS BAR PANEL
DG SUPPLY ONLY FOR LIGHT, POWER, UPS, ATM ONLY
A.C. SHOULD NOT OPERATE ON DG SUPPLY
All MCCB must have 25 KA S.C. current capacity
All outgoing feeder should have separate door and compartment.

Each outgoing feeder shall be with indicator.


(i) 100 Amp 4 - P, MCCB (3 Phase) 2 Nos. (A.C.)
(ii) 63 Amp 4 - P, MCCB (3 Phase) 5 Nos.
(Power, light. A.T.M., UPS)
(iii) 16 Amp DP, MCB (1 on each Phase) 2 Nos.
(iv) 63 Amp 4 - P, MCB (3 Phase) 4 Nos.

a S,F,T,I,C, Etc. of telephone tag box (krone) suitable for 50 pair housed Nos. 1
in GI box with cover of suitable size including termination.
b S, L, T, I, C Telephone point with cat 6 cable telephone cable from Nos. 15
main supply to various counters, tables, walls, partitions, etc.with
colour coading identification on both ends. Including 0.6 mm dia
annealed with tinned screen protected CU conductor PCC sheathed 2
pair telephone cable in PVC conduit 2.00 mm thk. conduit as required.
Including S & F modular type plate with telephone outlet box and RJ-
11 sockets with housed in zinc passivated box/ PVC box with suitable
connector strip in reseced wall/ partition as required. S & F modular
type telephone outlet 1 pair coaded outlet.

c 30 pair telephone cable in PVC conduit as main line including all rmt 20
connection & all accessories etc. complete.

11 Computer networking points with 4 pair, 24 AWG UTP Cat 6


Cable as per latest ammendments of TIA /EIA 568 B.2-1
Specifications in PVC Conduits including making connections to
Information outlets and Patch Panels with ferruling at both ends
for identifica
(a) Computer networking points with 4 pair, 24 AWG UTP Cat 6 Cable as Nos. 50
per latest ammendments of TIA /EIA 568 B.2-1 Specifications in PVC
Conduits including making connections to Information outlets and
Patch Panels with ferruling at both ends for identification with
necessary tools for punching, stripping, crimpping and testing
required. Cost including Faceplate for Flush Mount Information Outlets
Single Aperture with screw hole covers & Icon Tree Size
86mmX86mm including pvc/ ms box. (Cat 6 cable: Molex/
Avaya/Penduit/AMP) (Face plate i/o : Molex/ Avaya/Penduit/AMP)

SBI RACPC Jhalawar Electrical


Page 5

SBI UNIFORM LAYOUT & COLOUR SCHEME POLICY


SCHEDULE OF UNIT RATE TENDER 2019-20, SBI RACPC JHALAWAR
(A) INTERIOR FURNISHING WORKS
S.No Description Unit Quantity Rate Amount
(b) Supply , Installation and Testing of 4 pair , 100 Ohm, 24 AWG , E Cat
5 UTP, flexible , Double ended Patch Cords along with 2 No of RJ 45
connectors with strain relief boots as per TIA /EIA 568 B.2
Specifications including making connections to Inform outlets of
lengths.
1.0 Meter as required .Molex/ Avaya/Penduit/AMP) Nos. 50
2.0 Meter as required. Molex/ Avaya/Penduit/AMP) Nos. 50

(c) P,F,T,I,C, Etc. of Data/ server rack of 16U Rack with all required Nos. 1
accessories complete in all respect.
(d) 24 port patch panel for rack with all accessories Nos. 3

Total (B)

SBI RACPC Jhalawar Electrical