Control station-EN
Control station-EN
Contents
Ex-Installation Switches....................................................... F.1 III: Labels and Accessories ............................................ F.44
- Ex Safety Switch 10A .................................................... F.2 IV: Cable Entry and Flanges ........................................... F.46
- Ex Safety Switch 20A .................................................... F.4 Assembled Control Station ................................................ F.47
- Ex Safety Switch 40A .................................................... F.6 - Type GHG 411 ............................................................. F.48
- Ex Safety Switch 80A .................................................... F.8 - Type GHG 432 ............................................................. F.49
- Ex Safety Switch 125A ................................................ F.10 - Type GHG 434 ............................................................. F.50
- Ex Safety Switch 180A ................................................ F.12 Mounting Plate for Control Station .................................... F.51
Ex Control Switches .......................................................... F.14 Ex Control and Signal Units ............................................... F.52
Ex-Control Station .............................................................. F.19 - 418 811 Pushbutton &
I: Enclosure .................................................................... F.21 418 814 Double Pushbutton ........................................ F.53
II: Component ................................................................ F.26 - 418 812 Key-Operated Pushbutton ............................. F.56
- DRT Button & DDT Double Button .......................... F.27 - 418 8195 Key-Operated Switch................................... F.58
- SLT Key-Operated Pushbutton ................................ F.29 - 418 815 Mushroom-Head Pushbutton ........................ F.61
- SLS Key-Operated Switch ....................................... F.31 - 418 8190 Mini-Control Switch ..................................... F.65
- SGTE(Emergency Stop Pushbutton)/ - GHG249 Control Switch .............................................. F.67
SGT(Mushroom-head Pushbutton) .......................... F.33 - 418 8131 Potentiometer.............................................. F.70
- SCT Mini-Control Switch ........................................ F.36 - 418 8170 Signal Lamp ................................................. F.72
- POT Potentiometer.................................................. F.38 - AM 72 Measuring Instrument 413 84 ......................... F.74
- SIL Signal Lamp ...................................................... F.39 - Interchangeable AM72 ................................................ F.77
- AM45, AM72 Measuring Instrument ..................... F.40 - Label ............................................................................ F.78
- Ex 23, Ex 29 Control Switch .................................... F.42
Product Features
• The robust housings are made of a modified polyamide material.
• The switches are safe and reliable for both indoor and outdoor installations,
e.g. chemical factory or offshore etc.
• The large actuator surface of the installation switches allows perfect
operation, even when wearing working gloves.
• A protective collar prevents inadvertent operation.
• The toggle has a luminescent label which is free from radioactive additives.
• The switch can be installed easily while the cover is closed.
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / II 2 D T 80˚C
IECEx marking Ex ed IIC T6
Ex tD A21 IP66 T67˚C
Permissible ambient temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage 250V, 50 ~ 60Hz
Rated current 16A
Connecting terminals Switch terminals: 2x2.5mm2/ PE-terminals:4x2.5mm2
Degree of protection IP66
Cable gland Ex cable gland, the diameter M25 is from 8-17mm
Weight 0.32kg
Materials polyamide
Ordering Information
Type Contact arrangement Cable glands Order No.
1xM25 GHG 273 2000 R0017
ON-OFF switch 2-pole
2xM25 GHG 273 2000 R0018
*Provide copper base plate for metal gland connecting with 2xM20 poles. Please ask the ordering information for sales.
Dimension
Product Features
• Full AC-3 switching capacity.
• Isolating properties according to EN 60947-4-1 with compulsory opening of
the main current contacts.
• EMERGENCY STOP version is also available.
• Installation-friendly design and easily accessible connection terminals.
• Protected against inadvertent switching on by the integrated locking facility.
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / II 2 D IP66 T 80˚C
IECEx marking Ex ed IIC T6
Ex tD A21 IP66 T53˚C
Application temperature -20˚C ~ +40˚C1)
Rated voltage up to max. 550V
Rated current max.10A
Frequency 50/60Hz
Rated making-/breaking capacity AC-3
Ue 230V 10A
Ue 400V 10A
Ue 500V 10A
Back-up fuse
up to 400V up to 20A gL
up to 500V up to 16A gL
Main contact 2x1.5-2.5mm2
Auxiliary-/Signal contact 2x0.5-2.5mm2
Degree of protection acc. to EN 60529 IP66
Insulation class I
Cable glands/enclosure drilling M20(d=5-13mm)
M25(d=8-17mm)
Weight approx. 0.55kg
Enclosure material polyamide
Enclosure colour black
Auxiliary contact 1 x NO, making - lagging; breaking - leading
Padlocking can be locked in OFF position with 3 commercially available padlocks
1)
Other ambient temperature or request
Accessories
Mounting plate for Ex-safety switch 10 A 3-pole
Type Application Fixing method Order No.
1 wall mounting screw-on GHG 610 1953 R0101
1 pipe mounting screw-on GHG 610 1953 R0102
1 trellis mounting screw-on GHG 610 1953 R0103
Please refer to E.30-33 for the detailed information of mounting plates.
Dimension
84 112
X 68.5 80
X 61.5
102
Ø 5.5
Ø 8.5
Technical Data
ATEX marking II 2 G Ex ed ia IIC T6 / II 2 D IP66 T 80˚C
IECEx marking Ex ed ia IIC T6
Ex tD A21 IP66 T55˚C
Application temperature -20˚C ~ +40˚C1)
Rated voltage up to 690V
Rated current up to 20A
Frequency 50/60Hz
Rated making-/breaking capacity AC-3
Ue 230V 20A
Ue 400V 20A
Ue 500V 10A
Ue 690V 10A
Back-up fuse
up to 400V AC up to 35A gL
up to 500V AC up to 35A gL
up to 690V AC up to 25A gL
Main contact 2x4mm2
Auxiliary-/Signal contact 2x0.5-2.5mm2
Degree of protection acc. to EN 60529 IP66
Insulation class I
Cable glands/enclosure drilling M20(d=5-13mm)
M25(d=8-17mm)
M32(d=12-21mm)
option: metal flange with thread
Weight
3-pole approx. 1.48kg
6-pole approx. 2.43kg
Enclosure material glass-fibre reinforced polyester
Enclosure colour black
Auxiliary contact 1 x NO making - lagging; breaking - leading
1 x NC (only 6-pole version) making - leading; breaking - lagging
Padlocking can be locked in OFF position with 3 commercially available padlocks
1)
Other ambient temperature or request
Accessories
Mounting plate for Ex-safety switch 20 A 3-pole
Type Application Fixing method Order No.
2 wall mounting snap-on GHG 610 1953 R0104
2 pipe mounting snap-on GHG 610 1953 R0105
2 trellis mounting snap-on GHG 610 1953 R0106
Dimension
110 140 156
13 129 8
X 96 X 123-126
7 7
X150
170
X197
225
Technical Data
ATEX marking II 2 G Ex ed ia IIC T6 / II 2 D IP66 T 80˚C
IECEx marking Ex ed ia IIC T6
Ex tD A21 IP66 T53˚C
Application temperature -20˚C ~ +40˚C1)
Rated voltage up to 690V
Rated current up to 40A
Frequency 50/60Hz
Rated making-/breaking capacity AC-3
Ue 230V 40A
Ue 400V 40A
Ue 500V 40A
Ue 690V 32A
Back-up fuse
up to 400V AC up to 80A gL
up to 500V AC up to 80A gL
up to 690V AC up to 63A gL
Main contact 2x16mm2
Auxiliary-/Signal contact 2x4mm2
Degree of protection acc. to EN 60529 IP66
Insulation class I
Cable glands/enclosure drilling M25(d=8-17mm)
M40(d=16-28mm)
option: metal flange with thread
Weight
3-pole approx. 2.3kg
4-pole approx. 2.75kg
6-pole approx. 6.50kg
Enclosure material glass-fibre reinforced polyester
Enclosure colour black
Auxiliary contact 1 x NO making - lagging; breaking - leading
1 x NC (only 6-pole version) making - leading; breaking - lagging
Padlocking can be locked in OFF position with 3 commercially available padlocks
1)
Other ambient temperature or request
Accessories
Mounting plate for Ex-safety switch 40 A 3-pole
Type Application Fixing method Order No.
3 wall mounting snap-on GHG 610 1953 R0118
3 pipe mounting snap-on GHG 610 1953 R0110
3 trellis mounting snap-on GHG 610 1953 R0118
Dimension
140 8 156 271 275
X 123-126 Ø12 211
X 247 11
7
Ø7
X 247
271
X197
225
Technical Data
ATEX marking II 2 G Ex ed iaIIC T6 / II 2 D IP66 T 80˚C
IECEx marking Ex ed ia IIC T6
Ex tD A21 IP66 T53˚C
Application temperature -20˚C ~ +40˚C1)
Rated voltage up to 690V
Rated current up to 80A
Frequency 50/60Hz
Rated making-/breaking capacity AC-3
Ue 230V 80A
Ue 400V 80A
Ue 500V 80A
Ue 690V 63A
Back-up fuse
up to 400V AC up to 160A gL
up to 500V AC up to 160A gL
up to 690V AC up to 125A gL
Main contact 2x25mm2
Auxiliary-/Signal contact 2x4mm2
Degree of protection acc. to EN 60529 IP66
Insulation class I
Cable glands/enclosure drilling M25(d=8-17mm)
M32(d=12-21mm)
M40(d=21-35mm)
option: metal flange with thread
Weight
3-pole approx. 6.5kg
6-pole approx. 9.0kg
Enclosure material glass-fibre reinforced polyester
Enclosure colour black
Auxiliary contact 1 x NO making - lagging; breaking - leading
1 x NC making - lagging; breaking - leading
Padlocking can be locked in OFF position with 3 commercially available padlocks
1)
Other ambient temperature or request
Accessories
Mounting plate for Ex-safety switch 80 A 3-pole and 6-pole
Type Application Fixing method Order No.
3 2 x pipe mounting screw-on GHG 610 1953 R0110
Please refer to E.30-33 for the detailed information of mounting plates.
Dimension
271 275 271 295
X 247 Ø12 211 Ø12 211
11 X 247 11
Ø7 Ø7
X 247
271
271
X 247
Technical Data
ATEX marking II 2 G Ex de IIC T6 / II 2 D IP66 T 80˚C (6-pole without 2D certificate)
IECEx marking Ex de IIC T6
Ex tD A21 IP66 T53˚C
Application temperature -20˚C ~ +40˚C1)
Rated voltage up to 690V
Frequency 50/60Hz
Rated making-/breaking capacity AC-3
Ue 230V 125A
Ue 400V 125A
Ue 500V 125A
Ue 690V 110A
Back-up fuse
up to 400V AC up to 200A gL
up to 500V AC up to 200A gL
up to 690V AC up to 160A gL
Main contact
3-pole 1x50/70mm2
6-pole 6x95mm2/2x95mm2
Auxiliary-/Signal contact 2x4mm2
Degree of protection acc. to EN 60529 IP66
Insulation class I
Cable glands/enclosure drilling M25(d=8-17mm)
M40(d=16-28mm)
M63(d=27-48mm)
option: metal flange with 2 x thread
Weight
3-pole approx. 16kg
6-pole approx. 31kg
Enclosure material
3-pole glass-fibre reinforced polyester
6-pole steel, powder-coated
Enclosure colour
3-pole black
6-pole white
Auxiliary contact 1 x NO making - lagging; breaking - leading
1 x NC making - lagging; breaking - leading
Padlocking can be locked in OFF position with 3 commercially available padlocks
1)
Other ambient temperature or request
Accessories
Mounting plate for Ex-safety switch 125 A 3-pole
Type Application Fixing method Order No.
3 2 x pipe mounting screw-on GHG 610 1953 R0110
Please refer to E.30-33 for the detailed information of mounting plates.
Dimension
271 275 530 335
X 247 Ø12 211 X500
11 450
8
Ø7
544
X 520
X540
655
Terminals
35
Technical Data
ATEX marking II 2 G Ex de IIC T6 / II 2 D IP66 T 80˚C (6-pole without 2D certificate)
IECEx marking Ex de IIC T6, -55˚C~+45˚C
Ex tD A21 IP66 T53˚C
Application temperature -20˚C ~ +40˚C1)
Rated voltage up to 690V
Frequency 50/60Hz
Rated making-/breaking capacity AC-3
Ue 230V 180A
Ue 400V 180A
Ue 500V 180A
Ue 690V 125A
Back-up fuse
up to 400V AC up to 250A gL
up to 500V AC up to 250A gL
up to 690V AC up to 200A gL
Main contact
3-pole 1x120mm2
6-pole 6x150mm2/2x95mm2
Auxiliary-/Signal contact 2x4mm2
Degree of protection acc. to EN 60529 IP66
Insulation class I
Cable glands/enclosure drilling M25(d=8-17mm)
M40(d=16-28mm)
M63(d=27-48mm)
option: metal flange with 2 x thread
Weight
3-pole approx. 16.5kg
6-pole approx. 31.5kg
Enclosure material
3-pole glass-fibre reinforced polyester
6-pole steel, powder-coated
Enclosure colour
3-pole black
6-pole white
Auxiliary contact 1 x NO making - lagging; breaking - leading
1 x NC making - lagging; breaking - leading
Padlocking can be locked in OFF position with 3 commercially available padlock
1)
Other ambient temperature or request
Accessories
Mounting plate for Ex-safety switch 180 A 3-pole
Type Application Fixing method Order No.
3 2 x pipe mounting screw-on GHG 610 1953 R0110
Please refer to E.30-33 for the detailed information of mounting plates.
Dimension
271 275 530 335
X 247 Ø12 211 X500
11 450
8
Ø7
544
X 520
X540
655
Terminals
35
Product Features
• Original packaging from Germany is in high quality.
• The impact-resistant, glass-fibre-reinforced polyester enclosure
material is a prerequisite for withstanding even the most
rugged industrial operating conditions.
• A labyrinth seal in the cover guarantees the degree of protection
IP66. It is suitable for all indoor or outdoor environment with
safety and reliability.
• Easily accessible connection terminals.
• Have a terminal cross section up to 6mm2.
• Integrated locking facility.
• Significant cost saving with the CEAG mounting system.
Ex-control switch type 292 without and type 293 with measuring instrument
Technical Data
GHG29 GHG28
ATEX marking II 2 G Ex ed ia IIC T5 /T6 / II 2 G Ex ed ia IIC T5 /T6 /
II 2 D IP66 T 80˚C II 2 D IP66 T 80˚C
IECEx marking Ex ed ia IIC T5 or T6 Ex ed ia IIC T5 or T6
Ex tD A21 IP66 T49˚C Ex tD A21 IP66 T49˚C
Application temperature -20˚C ~ 40˚C -20˚C ~ 40˚C
-55˚C ~ +47˚C (T6)…+55˚C (T5) (option) -55˚C ~ +47˚C (T6)…+55˚C (T5) (option)
Rated voltage up to 500 V up to 690V
Rated current 16A 20A
Rated current gold contacts 0.4A 0.4A
Overload range (Type GHG293 only) 10 fold - 25 sec. 10 fold - 25 sec.
25 fold - 4 sec. 25 fold - 4 sec.
50 fold - 1 sec. 50 fold - 1 sec.
indicated 1:1.5 indicated 1:1.5
Measuring range (Type GHG293 only) max. 0-25 A direct/n/1A max. 0-25 A direct/n/1A
Accuracy (Type GHG293 only) Class 2.5 Class 2.5
Circuit (Type GHG293 only) moving iron moving iron
Rated marking - / 230V/6A 230V/8A
rated breaking capacity AC15 400V/4A 400V/6A
Rated marking - / 24V/2A 24V/6A
rated breaking capacity DC3 230V/0.3A 230V/0.4A
Connecting terminals 2x0.5-2.5mm2 or 1x1.0-6.0mm2 2x0.5-2.5mm2 or 1x1.0-6.0mm2
Degree of protection acc. to EN 60529 IP66 IP66
Cable gland/Gland plates/ 1xM25 (Ø8-17mm)1)2) 1xM25 (Ø8-17mm)1)2)
Enclosure drilling
Dimension (L x W x H) 170x110x129mm 225x110x129mm
Weight approx. 1.1kg (1 level) approx. 1.9kg (1 level)
approx. 1.25kg (2 level) approx. 2.05kg (2 level)
approx. 1.40kg (3 level) approx. 2.20kg (3 level)
Enclosure materia polyamide polyamide
Enclosure colour black black
1)
A brass base-plate for mounting metal cable gland is available.
2)
Brass flange for metal entries available on request (except for II D at data of publication).
Code A B1 B2 C D E1 E2 F1 F2 F3 F4
GHG293/ 5/ 063/ 015/ 1/ 2/ 011/ GEH/ BO/ M25/ 1
Dimension
110 140
170 225
X150 X197
X 123-126
X 96
129 156
Product Features
• The enclosures consist of low-temperature impact-resistant thermoplastic
which provides a high resistance to chemicals.
• Wide components which can meet all requirement.
• Original package from Germany with Independent certificated Exed
components.
• Easily able to mount control and signal components with accuracy position.
• The well though out design with low side walls allows optimum cable
connection.
The ordering information for GHG41181, GHG432, GHG434 control stations (customize):
The order code is consisted of enclosure, components, label / accessory and cable entry/flange.
Part I: Enclosure
A B C
Internal Components
DRT DDT SGTE SGT SLT SLS "I-0-II" Blind plug KLM SIL
Pushbutton Double pushbutton Mushroom-head emergency Mushroom-head Key-operated Key-operated Terminal Signal lamp
(0, STOP=white/red)(1, START=white/blacl) stop pushbutton pushbutton pushbutton, pushbutton, 6x2x4mm2+1xPE Yellow, green,
Red, lockable Yellow non-lockable two positions three positions red, white
Key removable Key removable
Position No.
2NC 2NO 1NC/ 2NC 2NO 1NC/ 2NC 2NO 1NC/ 2NC 2NO 1NC/ 2NC 2NO 1NC/ 2NO 20-250V
1NO 1NO 1NO 1NO 1NO AC/DC
4
3
2
1
SCT mini-control switch Cable gland is mounted in the bottom of enclosure which is up to two (choose the number)
Please refer to the M20=5-13mm M20 with plug M20 with plug M20 metal cable gland M20 metal cable gland
detailed products M25=8-17mm M25 with plug M25 with plug 6-12mm, 8-16mm 8.5mm-16mm, 12-21mm
information in catalog
or contact the sales. M25 metal cable gland M25 metal cable gland
8.5-16mm, 12-21mm 12-21mm, 16-27.5mm
M20 M25 M20 M25 M20 M25 M20 M25 M20 M25
Type 41181 Type 41182 Type 41183 Type 432 Type 434
Dimension
85 77.5
85 77.5 38 5
38 5 2 AM45
AM72
1 AM45
1 1 5.6
X52
85
125
X92
5.6
40
115
155
X75 22
85 77.5
38 5
3 AM45 100 90
X88 6
AM72 2 AM45
EX23
2 2 5.6 AM72
2 Floors
EX23
40
5.2
1
X132
165
1 Floor
1
156
195
X 97
1 1
40
2 2 2
X 186
245
EX23 EX23
2 Floors 2 Floors
1 EX23 1
1 Floor
X = fixing dimension
Type 434 1~4 = the enclosure can be fixed with components
Dimension: (mm)
SCS422
121 91.5
X106 10.5
1
82mm
121
X82
2
106mm
SCS425 121
91.5
X106
10.5
1
202mm
2
2 3
X202
241
3
4
4 5
106mm
X = fixing dimension
Ordering Information
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12)
SCS42 5 A 1 B 1 D 1 K 1 Z 1
number of measuring measuring number of signal switch number of variable number of variable
Product two positions-120x120 (mm) signal
pushbutton pushbutton instrument instrument lamps switches resistor resistor
series five positions-120x240 (mm) lamp
no mark if not fix no mark if not fix no mark if not fix no mark if not fix no mark if not fix
5 6 5 6 13 14 15 16 17 18
3 4 3 4
7 8 9 10 11 12
1 2 1 2
1 2 3 4 5 6
3 4 3 4
11 12 13 14 15
1 2 1 2
6 7 8 9 19
148
134 136
X110 116
9 10 11 12
X 247
271
5 6 7 8
1 2 3 4
Z
Z
Ø7
11
285
271 136
X 247 116
X 247
271
31 32 33 34 35 36 31 32 33 34 35 36 26 27 28 29 30
25 26 27 28 29 30 21 22 23 24 25
25 26 27 28 29 30
19 20 21 22 23 24 16 17 18 19 20
19 20 21 22 23 24
31 32 33 34 35 36 26 27 28 29 30
13 14 15 16 17 18
25 26 27 28 29 30 21 22 23 24 25
7 8 9 10 11 12 19 20 21 22 23 24 16 17 18 19 20
1 2 3 4 5 6
13 14 15 16 17 18 11 12 13 14 15
1 2 3 4 5 6 1 2 3 4 5
26 27 28 29 30
Distance between Distance between
centres 40mm centres 50mm
21 22 23 24 25
16 17 18 19 20
21 22 23 24
11 12 13 14 15 17 18 19 20
6 7 8 9 19 13 14 15 16
1 2 3 4 5
21 22 23 24
17 18 19 20
Distance between centres 50mm
13 14 15 16
21 22 23 24
9 10 11 12
17 18 19 20 5 6 7 8
13 14 15 16 1 2 3 4
5 6 7 8
285
1 2 3 4 271 136
X 247 116
Distance between centres 60mm
285
271 136
X 247 116
X 247
X 793
817
X 520
544
Technical Data
ATEX marking II 2 G Ex ed IIC / I M2 Ex de I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Switching capacity 400V/16A AC-1/ 400V/ 4A AC-11
Degree of protection acc. to EN 60529 IP66
Type of mounting DIN rail mounting
Gasket material Neoprene (Standard), Fluoric Silicone or Viton on request
Enclosure colour Grey
2-Pole Version
Connecting terminals 2x2.5mm2
Dimensions (L x W x H) 59x31x45mm
Weight 0.15kg
4-Pole Version
Connecting terminals 4x2.5mm2
Dimensions (L x W x H) 59x73x45mm
Weight 0.35kg
1)
The 2-pole pushbutton needs one mounting area. The 4-pole pushbutton needs two mounting areas.
3NC+1NO 23 28
11 21 31 43 11 21 31 43
14 24 34 44 14 24 34 44
4NO 24 29
13 23 33 43 13 23 33 43
Technical Data
ATEX marking II 2 G Ex ed IIC / M2 Ex de
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Switching capacity 400V/16A AC-1/ 400V/ 4A AC-11
Degree of protection acc. to EN 60529 IP66
Type of mounting DIN rail mounting
Gasket material Neoprene (Standard), Fluoric Silicone or Viton on request
Enclosure colour Grey
Lock CEAG1 (others on request)
2-pole version
Connecting terminals 2x2.5mm2
Dimensions (L x W x H) 59x31x45mm
Weight 0.15kg
4-pole version
Connecting terminals 4x2.5mm2
Dimensions (L x W x H) 59x73x45mm
Weight 0.35kg
1)
The 2-pole pushbutton needs one mounting area. The 4-pole pushbutton needs two mounting areas.
Technical Data
ATEX marking II 2 G Ex ed IIC / M2 Ex de
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Switching capacity 400V/16A AC-1/ 400V/ 4A AC-11
Switching system Engaging-Engaging-Engaging
Degree of protection acc. to EN 60529 IP66
Type of mounting DIN rail mounting
Gasket material Neoprene (Standard), Fluoric Silicone or Viton on request
Enclosure colour Grey
Lock CEAG1 (others on request)
2-pole version
Connecting terminals 2x2.5mm2
Dimensions (L x W x H) 59x31x45mm
Weight 0.15kg
4-pole version
Connecting terminals 4x2.5mm2
Dimensions (L x W x H) 59x73x45mm
Weight 0.35kg
1)
The 2-pole pushbutton needs one mounting area. The 4-pole pushbotton needs two mounting areas.
For example:
Key-operated switch, 2NO, silver contact points, label" I O II"
SLS5 04 01
Technical Data
ATEX marking II 2 G Ex ed IIC / M2 Ex de
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Switching capacity 400V/16A AC-1/ 400V/ 4A AC-11
Switching system Engaging-Engaging-Engaging
Degree of protection acc. to EN 60529 IP66
Type of mounting DIN rail mounting
Gasket material Neoprene (Standard), Fluoric Silicone or Viton on request
Enclosure colour Grey
2-pole version
Connecting terminals 2x2.5mm2
Dimensions (L x W x H) 59x31x45mm
Weight 0.15kg
4-pole version
Connecting terminals 4x2.5mm2
Dimensions (L x W x H) 59x73x45mm
Weight 0.35kg
1)
The 2-pole pushbutton needs one mounting area. The 4-pole pushbutton needs two mounting areas.
For example:
Mushroom-head emergency stop pushbutton, 2NC, "0, 1, Start, Stop" label, red, silver contact points, hand-released
SGT 0 13 01 1 2
Technical Data
ATEX marking II 2 G Ex ed IIC / M2 Ex de
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Switching capacity 400V/16A AC-1/ 400V/ 4A AC-11
Switching system Engaging-Engaging-Engaging
Degree of protection acc. to EN 60529 IP66
Type of mounting DIN rail mounting
Gasket material Neoprene (Standard), Fluoric Silicone or Viton on request
Enclosure colour Grey
2-pole version
Connecting terminals 2x2.5mm2
Dimensions (L x W x H) 59x31x45mm
Weight 0.15kg
4-pole version
Connecting terminals 4x2.5mm2
Dimensions (L x W x H) 59x73x45mm
Weight 0.35kg
1)
The 2-pole pushbutton needs one mounting area. The 4-pole pushbutton needs two mounting areas.
engaging - engaging 6
90O
13 23 13 23
45°
90° 05 15
135°
14 24 45° 90° 135° 14 24
13 21 13 21
45°
90° 07 17
135°
14 22 45° 90° 135° 14 22
12223444 12 22 34 44
45°
135° 22 32
11213343 45° 135° 11 21 33 43
14243444 14 24 34 44
45°
135° 23 33
13233343 45° 135° 13 23 33 43
14243444 12 22 32 42
45°
135° 21 31
13233343 45° 135° 11 21 31 41
14243444 12 24 34 44
45°
135° 26 36
13233343 45° 135° 11 23 33 43
13233343 13 23 33 43
90°
45°
135° 25 35
14 243444 45°90° 135° 14 24 34 43
13 213341 13 21 33 41
45°
90°
135° 27 37
14223442 45°90° 135° 14 22 34 42
13 233343 13/23 33/43
45°
90°
135° 45°90° 135°
24 34
14243444 14 24 34 44
Potentiometer
Technical Data
ATEX marking II 2 G Ex ed IIC / M2 Ex de
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage max.250V
Power consumption max.1W
Resistance range 100-10000Ω
Switching capacity 400V/16A AC-1/ 400V/ 4A AC-11
Tolerance ±20%
Connecting terminals 2x2.5mm2
Degree of protection acc. to EN 60529 IP66
Dimension (L x W x H) approx. 59x31x45mm
Weight 0.15kg
Type of mounting DIN rail mounting
Enclosure colour Grey
Angle of rotation 270˚
Scale 0-100%
1)
The 2-pole pushbutton needs one mounting area. The 4-pole pushbutton needs two mounting areas.
Signal lamp
Technical Data
ATEX marking II 2 G Ex ed IIC / Ex II2 G Ex d ia IIC
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage
(Ex ed IIC) 20V-250V AC/DC
(Ex d ia IIC) 18V-30V DC
(Ex ed IIC) 12V-30V AC/DC
Rated current
(20V-250V) approx. 4-15mA
(10V-28V Ex d ia IIC) max.25mA
(12V-30V) max.24mA
Connecting terminals 2x2.5mm2
Degree of protection acc. to EN 60529 IP66
Dimensions (L x W x H) 59x31x45mm
Weight 0.15kg
Type of mounting DIN rail mounting
Enclosure colour Grey
AM 45 AM 72
Technical Data
moving iron moving coil
ATEX marking II 2 G Ex e IIC / I M 2 Ex e I II 2 G Ex ib IIC / I M 2 Ex ib I
Application temperature -20˚C ~ +40˚C -20˚C ~ +40˚C
-55˚C ~ +55˚C -55˚C ~ +55˚C
Rated voltage up to 420V(AM 45) up to 420V(AM 45)
up to 750V(AM 72) up to 750V(AM 72)
Overload range 10 fold - 25 sec. 10 fold - 5 sec.
25 fold - 4 sec.
50 fold - 1 sec.
indicated 1:1.5
Measuring range Max.0-25A direct/n/1A 0/4-24mA
Inductance Li <0.1mH
Capacitance Ci <0.1 nF
Winding specification of moving coil 26.5 windings
Internal resistance 2.5Ω+/- 30%
Open circuit voltage max. Ui 30V
Short circuit current max. li 150mA
Accuracy Class 2.5 Class 1.5
Movement moving iron moving coil
Connecting terminals 2x1.5-4mm2 2x1.5-4mm2
Degree of protection acc. to EN60529 IP66 IP66
Dimension (L x W x H) 50x45mm (AM45) 50x45mm (AM45)
72x72mm (AM72) 72x72mm (AM72)
Weight 0.35kg 0.35kg
Type of mounting DIN rail mounting DIN rail mounting
Enclosure colour Grey Grey
EX 23 EX 29
Technical Data
Ex 23 Ex 29
ATEX marking II 2 G Ex ed IIC / I M 2 Ex e I II 2 G Ex ed IIC / I M 2 Ex e I
Application temperature -20˚C ~ +40˚C -20˚C ~ +40˚C
-55˚C ~ +45˚C(option) -55˚C ~ +55˚C(option)
Rated voltage up to 500 V up to 500 V
Rated current 10A 16A 1)
Rated current gold contacts 0.4A 0.4A
Rated making-/rated breaking capacity
AC 15: 230V/6A 500V/4A 400V/4A 230V/6A
DC 13: 24V/2A 230V/0.5A 230V/0.3A 24V/2A
Connecting terminals 2x0.5-2.5mm2 2x0.5-2.5mm2 or 1x1.0-6.0mm2
Weight
1 tier: approx. 0.2kg approx. 0.25kg
2 tier: approx. 0.35kg approx. 0.40kg
3 tier: - approx. 0.55kg
Type of mounting DIN rail mounting DIN rail mounting
Enclosure colour Grey Black
1)
12 A cable section must be 2.5mm2
1/3 1 3 5 1 3 5
1 3 I II 45° 0 I
45° 90°
135° 135°
2 4 45° 135° 2 4 2 4 6 45° 90° 135° 2 4 6
1 3 1 3 5 1 3 5
1 3 I II 45° 0 I
45° 90°
135° 135°
2 4 45° 135° 2 4 2 4 6 45° 90° 135° 2 4 6
1 3 1 3 5 1 3 5
1 3 0 I 45° 0 I
45° 90°
135° 135°
2 4 45° 135° 2 4 2 4 6 45° 90° 135° 2 4 6
1 3 1/3 1 3 5 1 3 5
45° I 0 II I II III
45°
90° 90°
135° 135°
2 4 45° 90° 135° 2 4 2 4 6 45° 90° 135° 2 4 6
1 3 1 3 1 3 5
45° I 0 II 1 3 5 0 I
90° 45°
135° 135°
2 4 45° 90° 135° 2 4 2 4 6 45° 135° 2 4 6
1 3 1 3 1/3 5/7
0 I 1 3 5 7 I II
45° 45°
90° 135°
135° 2 4 68 45° 135° 2 4 6 8
2 4 45° 90° 135° 2 4
1 1 3 5 7 1/3 5/7
1 0 I 45° I 0 II
45° 90°
135° 135°
2 45° 135° 2 2 4 68 45° 90° 135° 2 4 6 8
45˚ 45˚
90˚
45˚ 45˚
45˚ 45˚
1 3 1 3 1 3 5
I 0 II 1 3 5 0 I
45°
90° 063 45°
135°
019
135°
2 4 45° 90° 135° 2 4 2 4 6 45° 135° 2 4 6
1 3 1 3 1/3 5/7
0 I 1 3 5 7 I II
45°
90° 067 45°
135°
033
135° 2 4 68 45° 135° 2 4 6 8
2 4 45° 90° 135° 2 4
1 1 3 5 7 1/3 5/7
1 0 I I 0 II
45°
135°
011 45°
90° 024
135°
2 45° 135° 2 2 4 68 45° 90° 135° 2 4 6 8
45˚ 45˚
Technical Data
MXK 4-Ex UT4/UT4 PE
ATEX marking II 2 G Ex e II II 2 G Ex e II/2 D Ex e II
Application temperature -50˚C ~ +55˚C -50˚C ~ +55˚C
Rated voltage up to 420 V up to 690 V
Rated current max. 27 A max. 30 A
Connecting terminals 0.14mm2-4mm2 muti-wire
4mm2
0.14mm2-6mm2 single-wire
Dimension 6.2mm width 47.7mmx6.2mm
Weight 0.01kg 0.01kg
Type of mounting NS35 DIN rail mounting NS35 DIN rail mounting
Enclosure colour Grey Grey
1 x signal lamp
X1 X2
20-250V AC/DC
coloured lens cover "white, red, green, yellow"
13 21
1 x double pushbutton DDT 1.05kg GHG4322288R0019
I 0 1NO+1NC
14 22
label: "O, I, START, STOP", brass base plate, 2 x M25 drilling on the bottom
with two exe certificated plastic plugs
1 x signal lamp
20-250V AC/DC
X1 X2
coloured lens cover "white, red, green, yellow"
key-operated switch
13 23 2NO
I 0 II 1.10kg GHG4322288R0020
() SW 5"engaging-engagingengaging
14 24 label: "I O II" brass base plate, 2 x M25 drilling on the bottom
with two exe certificated plastic plugs
label: "I O II" brass base plate, 2 x M20 drilling on the bottom
with two exe certificated plastic plugs
13 21
1 x control switch GHG23
I 0
2NO + 1NC
14 22
13 21 SW 5 "engaging-engagingspring" 1.02kg GHG4321288R0051
label: "I II III" brass base plate, 2 x M25 drilling on the bottom
14 22 with two exe certificated plastic plugs
Type 1 Type 2
Product Features
• The panel-mounting is easy.
• The single-wire installation is clear and simple.
• All panel-mounted apparatus can be retrofitted for cable connection with a
slip-on strain relief and protective cover which is then completely certified.
• The completely certified measuring instruments for direct and indirect
measurement are available for different amperage ranges.
• Standard actuator-element size of Ø 30.5 mm.
• Original packaging from Germany.
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / I M2 Ex e I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Rated making-/rated breaking capacity
AC15 250V/6A 500V/4A
DC13 24V/6A 220V/1A
Connecting terminals 2x2.5mm2
Degree of protection acc. to EN 60529 IP66
Dimension (L x W x H) approx. 59 x 31 x 45 mm
Weight 0.20kg
Type of mounting Ø 30.5 mm fixing hole
Enclosure colour Grey
Gasket material Neoprene (Standard), Fluoric silicone or viton on request
B 2NC 3 6
12 22
13 23
2NO 4 7
14 24
13 21
1NO+1NC 5 8
14 22
Accessories
Type OU Order No.
Protective cover to meet IP66 5 GHG410 1939 R0002
Please note that we can only deliver in the ordering units (OU) stated in the tables above.
Dimension
3.1+0.1
68 57 65
31.5 +0.2
5 40 30.3 +0.2
14 77 38
126
Ø 38 57
10
140
Double pushbutton with protective cover
Key-operated Pushbutton
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / I M2 Ex e I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Rated making-/rated breaking capacity
AC15 250V/6A 500V/4A
DC13 24V/6A 220V/1A
Connecting terminals 2x2.5mm2
Degree of protection acc. to EN 60529 IP66
Dimension (L x W x H) approx. 59 x 31 x 45 mm
Weight 0.20kg
Type of mounting Ø 30.5 mm fixing hole
Enclosure colour grey
Gasket material Neoprene (Standard), Fluoric silicone or viton on request
1NO+1NC 5 8
14 22
Code Function Pushbutton not pressed Key Pushbutton pressed Key Code
C lockable removable lockable removable 10
lockable removable lockable not removable 11
lockable removable not lockable not removable 12
lockable not removable lockable removable 13
not lockable not removable lockable removable 14
not lockable removable auto lockable removable 15
Key-operated Pushbutton
Accessories
Type OU Order No.
Protective cover to meet IP66 5 GHG410 1939 R0002
Please note that we can only deliver in the ordering units (OU) stated in the tables above.
Dimension
3.1 +0.1
57 65
31.5 +0.2
56
5 40 30.3 +0.2
77 38
126
57
10
Key-operated switch
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / I M2 Ex e I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Rated making-/rated breaking capacity
AC15 250V/6A 500V/4A
DC13 24V/6A 220V/1A
Connecting terminals 2x2.5mm2
Switch system Engaging-Engaging-Engaging
Dimension (L x W x H) approx. 59 x 31 x 45 mm
Weight 0.15kg
Type of mounting Ø 30.5 mm fixing hole
Enclosure colour grey
Latch point CEAG1 (others on request)
Key-operated switch
Accessories
Type OU Order No.
Protective cover to meet IP66 5 GHG410 1939 R0002
Please note that we can only deliver in the ordering units(OU) stated in the tables above.
Dimension
57
62
5
77 38
126
57
10
3.1 +0.1
65
31.5 +0.2
40 30.3 +0.2
Minimum distance
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / I M2 Ex e I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Rated making-/ra ted breaking capacity AC-15: 250V/6A 500V/4A
DC-13: 24V/6A 220V/1A
Connecting terminals 2x2.5mm2
Dimension (L x W x H) approx. 59 x 31 x 45 mm
Weight 0.15kg
Type of mounting Ø 30.5 mm fixing hole
Enclosure colour grey
Gasket material Neoprene (Standard), fluoric silicone or viton on request
B 2NC 3 6
12 22 12 22
13 23 13 23
2NO 4 7
14 24 14 24
13 21 13 21
1NO+1NC 5 8
14 22 14 22
Key released
2NC Red German/English GHG418815 3 R1 3 00
2NO Red German/English GHG418815 4 R1 3 00
1NO+1NC Red German/English GHG418815 5 R1 3 00
Accessories
Type OU Order No.
Protective cover to meet IP66 5 GHG410 1939 R0002
Please note that we can only deliver in the ordering units(OU) stated in the tables above.
Dimension
57
56
5
77 38
Mushroom-head pushbutton without protective cover
with key release
57
30
5
77 38
126
57
30
10
3.1+0.1
65
31.5 +0.2
40 30.3 +0.2
Minimum distances
Mini-control switch
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / I M2 Ex e I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage 500V AC
Rated current 16A
Rated current gold contacts 0.4A
Rated making-/rated breaking capacity
AC15 250V/6A 500V/4A
DC13 24V/6A 220V/1A
Connecting terminals 2x2.5mm2
Dimension (L x W x H) approx. 59 x 31 x 45 mm
Weight 0.15kg
Type of mounting Ø 30.5 mm fixing hole
Enclosure colour grey
90˚
6 45°
45°
135°
13 23 13/23
2 0 I GHG 418 8190 R 6 2 01
90°
1424 45° 135° 14 24
45˚ 45˚ 135°
14 24 45° 90° 135° 14 24
13 21
13 21
90˚
6 45° 13 23
135°
45°
13 23
1 I II GHG 418 8490 R 6 1 02
1422
90° 45° 135° 14 22
45˚ 45˚ 135°
13
1423
24 45° 90° 135° 14 24
13/23
45°
45˚ 45˚
5 90° 13 21
45°
135°
13 21
3 I 0 II GHG 418 8190 R 5 3 07
90°14 24 45° 90° 135° 14 24
45˚ 45˚ 135°
1423
22 45° 90° 135° 13 14 22
23
13
45°
45˚ 45˚
5 90°
135°
5 I 0 II GHG 418 8190 R 5 5 07
14 24 45° 90° 135° 14 24
13 21 13 21
45°
45˚ 45˚ 8 90°
135°
7 0 I GHG 418 8190 R 8 7 01
14 22 45° 90° 135° 14 22
Accessories
Type OU Order No.
Protective cover to meet IP66 5 GHG410 1939 R0002
Please note that we can only deliver in the ordering units (OU) stated in the tables above.
Dimension
150
57
150
57
57
57
24
57
5 24
77 38
57
57
5
10
Mini-control switch without protective cover Mini-control switch with protective cover
57
24
3.1 +0.1
5 24
77 38
5
10
65
31.5 +0.2
3.1 +0.1
65 40 30.3 +0.2
Minimum distance 31.5 +0.2
40 30.3 +0.2
EATON’S CROUSE-HINDS BUSINESS F.66
GHG249 Control Switch
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / I M2 Ex e I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage up to 690V AC
Rated current up to 20A
Rated current gold contacts up to 0.4A
Rated making-/rated breaking capacity
AC3 230V/8A 400V/6A
AC11 24V/6A 230V/0.4A
Connecting terminals 2x2.5mm2 multi-wire, 6mm2 single wire
Weight 0.55kg
Type of mounting Ø 30.5 mm fixing hole
Enclosure colour grey
Dimension
20
20 20
71
50
71
71
50
50
72
72 72 a 34
85 a a 34 34
85 85
2…6
6 2…6 2…6
6 6
5430
54
30
30
54
30 °
30 ° 30 °
Potentiometer
Technical Data
ATEX marking II 2 G Ex ed IIC T6 / I M2 Ex e I
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C (option)
Rated voltage up to 250V AC
Power consumption max. 1W
Resistance range 100-10000Ω
Tolerance ±20%
Connecting terminals 2x2.5mm2
Dimension (L x W x H) approx. 59 x 31 x 45 mm
Weight 0.15kg
Type of mounting Ø 30.5 mm fixing hole
Angle of rotation 270˚
Scale 0-100%
Colour grey
Potentiometer
Accessories
Type OU Order No.
Protective cover to meet IP66 5 GHG410 1939 R0002
Please note that we can only deliver in the ordering units (OU) stated in the tables above.
Dimension
126
57
57 3.1+0.1
24
65
31.5 +0.2
5
77 38 10
40 30.3 +0.2
Potentiometer without protective cover Potentiometer with protective cover Minimum distance
Signal lamp
Technical Data
ATEX marking II 2 G Ex ed IIC/ II 2 G Ex d ia IIC
Application temperature -20˚C ~ +40˚C
-55˚C ~ +55˚C(option)
Rated voltage
(Ex ed IIC) 20V to 250V AC/DC
(Ex d ia IIC) 10V to 28V DC
(Ex ed IIC) 12V to 30V AC/DC
Rated current
(20V to 250V) approx. 4-15mA
(10V to 28V Ex d ia IIC) max. 25mA
(12V to 30V) max. 24mA
Connecting terminals 2x2.5mm2
Dimension (L x W x H) approx. 59 x 31 x 45 mm
Weight 0.15kg
Type of mounting Ø 30.5 mm fixing hole
Enclosure colour grey
Signal lamp
Accessories
Type OU Order No.
Protective cover to meet IP66 5 GHG410 1939 R0002
Please note that we can only deliver in the ordering units (OU) stated in the tables above.
Dimension
126
57
57
21
5
77 38 10
Signal lamp without protective cover Signal lamp with protective cover
3.1+0.1
65
31.5 +0.2
40 30.3 +0.2
Minimum distances
Technical Data
Moving iron Moving coil
ATEX marking II 2 G Ex e IIC / I M 2 Ex e I II 2 G Ex ib IIC / I M 2 Ex ib I
Application temperature -20˚C ~ +40˚C -20˚C ~ +40˚C
-55˚C ~ +55˚C (option) -55˚C ~ +55˚C (option)
Rated voltage up to 690V up to 690V
Power consumption max. 0.31 VA max. 0.31 VA
Overload range 10 fold - 25 sec. 10 fold - 5 sec.
25 fold - 4 sec.
50 fold - 1 sec.
indicated: 1:1.5
Measuring range max. 0-25 A direct/ n / 1A 0/4-24mA
Inductance Li <0.1mH
Capacitance Ci <0.1 nF
Winding specification of moving coil 26.5 windings
Internal resistance 2.5Ω+/- 30%
Open circuit voltage Ui 30V
Short circuit current li 150mA
Accuracy Class 2.5 Class 1.5
Connecting terminals 2x1.5-4mm2 2x1.5-4mm2
Degree of protection acc. to EN 60529 IP66 IP66
Cable glands/Gland plates/Enclosure drilling 1xM25(Ø8-17mm) 1xM25(Ø8-17mm)
Dimension (L x W x H) 160x95x62mm 160x95x62mm
Display size AM72 72x72mm 72x72mm
Weight 0.8kg 0.8kg
Type of mounting DIN rail mounting DIN rail mounting
Enclosure colour grey grey
Measuring instrument AM 72, Ct connection, n/1A, version with 1 x cable entry M25
0 - 1 / 1.5 A GHG 412 8282 R0002
0 - 2.5 / 3.75 A GHG 412 8282 R0003
0 - 5 / 7.5 A GHG 412 8282 R0004
0 - 10 / 15 A GHG 412 8282 R0005
0 - 15 / 22.5 A GHG 412 8282 R0006
0 - 20 / 30 A GHG 412 8282 R0008
0 - 30 / 45 A GHG 412 8282 R0009
0 - 40 / 60 A GHG 412 8282 R0010
0 - 50 / 75A GHG 412 8282 R0011
0 - 60 / 90 A GHG 412 8282 R0012
0 - 75 / 112.5 A GHG 412 8282 R0013
0 - 100 / 150 A GHG 412 8282 R0014
0 - 150 / 225 A GHG 412 8282 R0015
0 - 200 / 300 A GHG 412 8282 R0016
0 - 250 / 375 A GHG 412 8282 R0017
0 - 300 / 450 A GHG 412 8282 R0018
0 - 400 / 600 A GHG 412 8282 R0019
0 - 500 / 750 A GHG 412 8282 R0020
0 - 600 / 900 A GHG 412 8282 R0021
0 - 100% / 150% A GHG 412 8282 R0031
Dimension
95 26
160 73 147 73
173
22
62
Interchangeable AM72
Label
Order Code
Labels for pushbutton
Inscription Order No. Inscription Order No.
0, I Start, Stop 001 0 002
I 003 II 004
D 005 STOP 006
START 007 NOT-AUS 008
LANGSAM 009 SCHNELL 010
EMERG.STOP 011 - 012
ARRET 014 MARCHE 015
AUF 016 AB 017
Neutral whtie 018 Neutral green 019
0, I, Arret, Marche 020 UP 024
DOWN 025 ZU 026
ON 027 OFF 028
+ 030 - 031
Neutral red 033 Neutral yellow 034
EIN 036 AUS 037
AUTO 039 HAND 050
SENKEN 051 HEBEN 052
LINKS 053 RECHTS 054
FAST 055 SLOW 056
RESET 057 OPEN 058
HALT 069 III 070
VOR 073 ZURÜCK 074
FIRE ALARM 094 FORWARD 095
REVERSE 096 RUN 100
HIGH 101 LOW 102
LP 151 HQ 152
LQ 157 ST ÖR.QUIT 162
SPERREN 163 ENTSPERREN 164
ENTRIEGELN 165 VERRIEGELN 166
Special labels are available on request.