Neither iFixit nor this repair information is endorsed by or affiliated with the medical device manufacturer. GE Carescape R860 Display Unit Disassembly There are no questions. Be the first to ask a question! For additional help on the GE Carescape R860, check out the device's troubleshooting page. The CARESCAPE R860 combines sophisticated
technology and an intuitive user interface. Icons represent configurable views of past (historical trends), present (patient status), and future patient needs (clinical decision support). The ventilator consists of a display, ventilator unit, cart with AC outlet (optional), EVair compressor (optional), and module bay with gas module (optional). A wide
selection of performance options give the user full control of the system configuration. This ventilator is a complete system featuring patient ventilation, monitoring, and the capability of interfacing with central monitoring. Full touchscreen capability allows the user to quickly and easily access patient information and procedures. This ventilator
supports adult, pediatric, and neonatal patients.
The basic ventilator is equipped with adult and pediatric patient type software. The neonatal software option can be added or the ventilator can be set to enable the Neonatal-Only option. When the Neonatal-Only option is set, the ventilator is only intended to be used for neonatal patients and will not be able to enter the adult or pediatric patient
types.
This ventilator comes with standard ventilation modes as well as a purchasable neonatal patient option, ventilation modes, and clinical decision support features. Height: 48.85 cm/19.2 in (Display down); 73.8 cm/29.1 in (Display up)Height including cart: 126.82 cm/49.9 in (Display down); 151.77 cm/59.8 in (Display up)Width: 38 cm/15 in Depth: 36
cm/14 inWeight: 38 cm/15 in Depth: 36 cm/14 inDisplay motion Vertical tilt: 162.1° in raised position; 47.6° in lowered positionHeight adjustment: 24.95 cm/9.8 inVentilation ModesA/C VC (Volume Control)A/C PC (Pressure Control)A/C PRVC (Pressure Regulated Volume Control)SIMV VC (Synchronized Intermittent Mandatory Ventilation, Volume
Control)SIMV PC (Synchronized Intermittent Mandatory Ventilation, Pressure Control)CPAP/PS (Continuous Positive Airway Pressure/ Pressure Support)SBT (Spontaneous Breathing Trial)APRV* (Airway Pressure Release Ventilation)BiLevel* (BiLevel Airway Pressure Ventilation)BiLevel VG* (BiLevel with Volume Guarantee)SIMV PRVC*
(Synchronized Intermittent Mandatory Ventilation, Pressure Regulated Volume Control)VS* (Volume Support)NIV* (Non-invasive Ventilation ForumsDocumentsVideosNews The logical path to Lung ProtectionCARESCAPE* R860 GE Healthcare With the inception of the CARESCAPE R860, we were inspired to create a user interface that is inherently
familiar the first time you use it. Through hours of observational research and leveraging swipe screen touchscreen technology, weve designed a more human-centered user interface. By replacing menus with workspace views, the CARESCAPE R860 has flattened the learning curve and unlocked ventilation capabilities by making them more
accessible and easier to use. The end goal has always been to provide a clearer window to your patients. Through useful data to support clinical decisions and convenient workspaces that can be customized for each patient, you can confidently provide a logical path to Lung Protection. Its nice to see a familiar interface MENU-FREE NAVIGATION The
user interface on the CARESCAPE R860 represents a leap forward in our touchscreen technology.
Intuitively organized and easily accessible, relevant clinical content and therapy controls are not buried in menus, they are at your fingertips.
The user interface on the CARESCAPE R860 puts you in the director's chair through graphically dynamic views. From simple parameters and waveforms to robust clinical displays and historical trends, theres a view to help to suit your needs. Choose your view, youre the director With the CARESCAPE R860 user interface we have enabled you to
freely switch between workspaces with either a single button touch or swipe from past on the left to future on the right to monitor your patient trends and access your Lung Protection tools. Travel through time with a single touch THE WORKSPACES From these workspaces, users can swipe and scroll to transport them wherever they want to go to
the past (trends), the present (patient status) and the future (therapy controls) PAST PRESENT FUTURE PAST PRESENT FUTURE EVENT-CENTRIC HISTORICAL DATA SLIDE THE CURSOR TO SELECT TIME OR EVENT AND EXPAND ALL THE RELATED CLINICAL DATA TO DEEP DIVE Keep focus where neededThe CARESCAPE R860 has an
event-centric historical data feature that allows you to easily access detailed patient data at a given point in time.
Events can be expanded with the touch of a button to reveal important patient information. Did you know? 24%of all patients mechanically ventilated will develop Ventilator Induced Lung Injury (VILI) for reasons other than ALI or ARDS.7 Approximately A LUNG PROTECTION STRATEGY CAN HELP ENSURE THE DIFFERENT ZONES RECEIVE THE
TREATMENT THEY NEED LUNG ZONE Atelectasis Baby healthy lung Cycling opening/closing CLINICAL NEED Keep the lung open2,3,4 Reduce tidal volume4,5 Stabilize the lung (PEEP)6 A B C The lung is a delicate structure that is highly sensitive. Mechanical ventilation can be detrimental if too much volume or pressure is delivered. And patients
affected by lung disease are highly susceptible to ventilation-associated lung injury.1 Gentler breaths for easy breathing 1 E. D. Moloney and M. J. D. Griffiths, British Journal of Anaesthesia 92 (2): 26170 (2004)2 Hedenstiernia G, Acta Anesthesiol Scand 2012, 56: 675-6853 Gattinoni L, N Engl J Med 2006;354:1775-864 Brunner J, Intensive Care Med.
2009, 35:1479-835 Rouby JJ, Anesthesiology 2004; 101: 228346 Gattinoni L, Current Opinion in Critical Care 2004, 10:2722787 International consensus conferences in intensive care medicine: Ventilator-associated Lung Injury in ARDS. This official conference report was cosponsored by the American Thoracic Society, The European Society of
Intensive Care Medicine, and the Societ de Ranimation de Langue Franaise, and was approved by the ATS Board of Directors, July 1999. Am J Respir Crit Care Med 1999; 160:2118. The logical path to Lung Protection 8 Chlumello D, Crit Care Med 2008, 12:R150 dol:10:1186/cc7139 CARESCAPE R860 is an intuitive ICU ventilator that offers a
comprehensive solution for Lung Protection strategy by simplifying the use of advanced tools to assess patients lung volume, check potential recruitability and titrate the appropriate PEEP.
LUNG ZONE Atelectasis Baby healthy lung Cycling opening/closing CARESCAPE R860 ADVANCED TOOLS FRC & static compliance P-V curve PEEP titration & Vd/Vt FRC INview8 SpiroDynamics PEEP INview & Vent Calcs A B C CARESCAPE R860 OFFERS AN INTEGRATED SOLUTION CLINICAL DECISION SUPPORT SBT FRC Spiro Metabolics
Calc STATUS Basic Basic Waveform Advanced Waveform Split Screen Charting TRENDS Graphic Trends Numerical Trends Trends Log Snapshot Trends PAST PRESENT FUTURE CARESCAPE R860The logical path to Lung Protection AB C D G H E F Connecting intelligence and careThis is the vision of our CARESCAPE platform. For caregivers, this
means a user interface that is designed to improve access to core functions and open a window to the patient.
From respiratory care to patient monitoring, with CARESCAPE we contribute to suit the needs of clinical users regardless of experience or title. CARESCAPE R860 Uncompromised ventilation along with touches of brilliance now you can have it all Alarm light 15" Touch display Integrated keypad & trim knob Optional airway module bay (mounted
either side) Inspiratory safety guard Ventilator lock Dovetail to support adjustable mounting rail (on both sides) Locking casters (all wheels lock) A B C D E F G H www.gehealthcare.com GE Healthcare provides transformational medical technologies and services that are shaping a new age of patient care. Our broad expertise in medical imaging and
information technologies, medical diagnostics, patient monitoring systems, drug discovery, biopharmaceutical manufacturing technologies, performance improvement and performance solutions services help our customers to deliver better care to more people around the world at a lower cost. In addition, we partner with healthcare leaders, striving
to leverage the global policy change necessary to implement a successful shift to sustainable healthcare systems. Imagination at work GE Healthcare P.O. Box 900, FIN-00031 GE, Finland GE Direct United Kingdom: +44 (0)800 0329201 www.gehealthcare.com Data subject to change.Marketing Communications GE Medical SystemsSocit en
Commandit Simple au capital de 85.418.040 Euros283 rue de la Minire 78533 Buc Cedex FranceRCS Versailles B 315 0130359A General Electric Company, doing business as GE Healthcare. GE and GE monogram are trademarks of General Electric Company*Trademark of General Electric company 2014 General Electric Company. All rights
reserved. JB23620GB 9/14 Erfahren Sie mehr über die Funktionsweise der lungenprotektiven Beatmungstools mit dem CARESCAPE R860 Ventilator.Spezifikationen anfordernErfahren Sie, wie Sie mit GE Healthcare Ihre betriebliche Effizienz steigern und klinische Exzellenz erreichen können, ganz gleich, ob Sie Hilfe bei der Verwaltung Ihrer
Beatmungsgeräte oder Remote-Support nach der Installation benötigen.