Engineering Drawing Report
Engineering Drawing Report
23 T2 T2
24
22 25
5 7
4 W4 8
W2 W3 W3 W2
3 T1 T1 9
W1 W1
2 10
1 HW1
B1 B2
HW1 11
15 26 27 14 13 28 29 12
Scale = 1:71.7
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.70 Vert(LL) -0.32 13-15 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.95 Vert(CT) -0.58 13-15 >706 180
TCDL 10.0 Rep Stress Incr YES WB 0.51 Horz(CT) 0.10 10 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 187 lb FT = 20%
11
10 12
T2 T2
449 13
45
8 14
67 ST8 1516
ST7 ST7
5 ST6 ST6 17
ST5 ST5
4 18
T1 ST4 ST4 T1
3 ST3 ST3 19
ST2 ST2
ST1 ST1
2 20
1 HW1 HW1 21
B1 B2
Scale = 1:64.3
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.07 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.07 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.17 Horz(CT) 0.00 20 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 239 lb FT = 20%
LUMBER 3) Truss designed for wind loads in the plane of the truss
TOP CHORD 2x4 SP No.2 only. For studs exposed to wind (normal to the face),
BOT CHORD 2x4 SP No.2 see Standard Industry Gable End Details as applicable,
OTHERS 2x4 SP No.3 or consult qualified building designer as per ANSI/TPI 1.
WEDGE Left: 2x4 SP No.3 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Right: 2x4 SP No.3 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
BRACING Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
TOP CHORD Structural wood sheathing directly applied or 5) Unbalanced snow loads have been considered for this
6-0-0 oc purlins. design.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc 6) This truss has been designed for greater of min roof live
bracing. load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
WEBS 1 Row at midpt 11-29, 10-31, 12-28 overhangs non-concurrent with other live loads.
MiTek recommends that Stabilizers and 7) All plates are 1.5x4 MT20 unless otherwise indicated.
required cross bracing be installed during 8) Gable requires continuous bottom chord bearing.
truss erection, in accordance with Stabilizer 9) Gable studs spaced at 2-0-0 oc.
Installation guide. 10) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
REACTIONS All bearings 34-0-0.
11) * This truss has been designed for a live load of 20.0psf
(lb) - Max Horiz 2=163 (LC 15), 38=163 (LC 15)
on the bottom chord in all areas where a rectangle
Max Uplift All uplift 100 (lb) or less at joint(s) 3-06-00 tall by 2-00-00 wide will fit between the bottom
22, 23, 24, 25, 26, 27, 28, 31, 32, chord and any other members.
33, 34, 35, 36, 37 12) Provide mechanical connection (by others) of truss to
Max Grav All reactions 250 (lb) or less at joint bearing plate capable of withstanding 100 lb uplift at joint
(s) 2, 20, 22, 23, 24, 25, 26, 27, 28, (s) 31, 32, 33, 34, 35, 36, 37, 28, 27, 26, 25, 24, 23, 22.
29, 31, 32, 33, 34, 35, 36, 37, 38, 13) This truss is designed in accordance with the 2018
41 International Residential Code sections R502.11.1 and
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 R802.10.2 and referenced standard ANSI/TPI 1.
(lb) or less except when shown.
LOAD CASE(S) Standard
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=34ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-6-5, Exterior(2N) 2-6-5 to 17-0-0, Corner(3R) 17-0-0 to
20-4-13, Exterior(2N) 20-4-13 to 34-10-8 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
Job Truss Truss Type Qty Ply
B30812 Gardner T02G Roof Special Structural Gable 1 1 Job Reference (optional)
K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:27 Page: 1
ID:h8hwR9jjO4Fj8w_rq2k6sQzNNeO-SpBpOKJk_tlQo4VcohjZ4cJNR_MyffoKHjy69QzNIA_
4
32
42 33
34
41 T2
3 5
T1 W4
W2 W3 W3 W5
2
W6 ST1 T3 7
ST2
W1 35
W7 ST4W8 ST5 36
1 ST3 ST6 8 9
HW1
B1 B2
16 37 38 15 14 39 40 13
Scale = 1:72.8
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.85 Vert(LL) -0.29 15-16 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.91 Vert(CT) -0.52 15-16 >778 180
TCDL 10.0 Rep Stress Incr YES WB 0.96 Horz(CT) 0.06 12 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 229 lb FT = 20%
LUMBER 1) Unbalanced roof live loads have been considered for this
TOP CHORD 2x4 SP No.2 design.
BOT CHORD 2x4 SP No.1 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
WEBS 2x4 SP No.3 Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
OTHERS 2x4 SP No.3 B=45ft; L=40ft; eave=5ft; Cat. II; Exp B; Enclosed;
WEDGE Left: 2x4 SP No.3 MWFRS (directional) and C-C Exterior(2E) 0-0-0 to
4-0-11, Interior (1) 4-0-11 to 17-0-0, Exterior(2R) 17-0-0
BRACING
to 21-0-0, Interior (1) 21-0-0 to 40-10-8 zone; cantilever
TOP CHORD Structural wood sheathing directly applied or left and right exposed ; end vertical right exposed;C-C
2-2-0 oc purlins. for members and forces & MWFRS for reactions shown;
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc Lumber DOL=1.60 plate grip DOL=1.60
bracing. 3) Truss designed for wind loads in the plane of the truss
WEBS 1 Row at midpt 3-15, 5-15 only. For studs exposed to wind (normal to the face),
MiTek recommends that Stabilizers and see Standard Industry Gable End Details as applicable,
required cross bracing be installed during or consult qualified building designer as per ANSI/TPI 1.
truss erection, in accordance with Stabilizer 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Installation guide. Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
REACTIONS All bearings 6-3-8. except 1=0-3-8 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
(lb) - Max Horiz 1=-159 (LC 14) 5) Unbalanced snow loads have been considered for this
Max Uplift All uplift 100 (lb) or less at joint(s) design.
8, 29 except 11=-119 (LC 2) 6) This truss has been designed for greater of min roof live
Max Grav All reactions 250 (lb) or less at joint load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
(s) 8, 10, 11, 29 except 1=1478 (LC overhangs non-concurrent with other live loads.
28), 12=2053 (LC 29) 7) All plates are 1.5x4 MT20 unless otherwise indicated.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 8) Gable studs spaced at 2-0-0 oc.
(lb) or less except when shown. 9) This truss has been designed for a 10.0 psf bottom
TOP CHORD 4-32=-1363/191, 32-33=-1428/171, chord live load nonconcurrent with any other live loads.
33-34=-1447/166, 5-34=-1513/165, 10) * This truss has been designed for a live load of 20.0psf
5-6=-1921/166, 6-7=-1810/109, on the bottom chord in all areas where a rectangle
7-35=-22/651, 35-36=-33/595, 8-36=-41/576, 3-06-00 tall by 2-00-00 wide will fit between the bottom
1-2=-2406/163, 2-3=-2255/163, chord and any other members, with BCDL = 10.0psf.
3-41=-1510/158, 41-42=-1444/170, 11) Provide mechanical connection (by others) of truss to
4-42=-1418/194 bearing plate capable of withstanding 100 lb uplift at joint
BOT CHORD 1-16=-73/2133, 16-37=-10/1759, (s) 8, 8 except (jt=lb) 11=118.
37-38=-10/1759, 15-38=-10/1759, 12) This truss is designed in accordance with the 2018
14-15=0/1533, 14-39=0/1533, 39-40=0/1533, International Residential Code sections R502.11.1 and
13-40=0/1533, 12-13=-561/69, R802.10.2 and referenced standard ANSI/TPI 1.
11-12=-561/69, 10-11=-561/69, 8-10=-561/69 LOAD CASE(S) Standard
WEBS 3-16=0/493, 3-15=-660/145, 4-15=-58/1119,
5-15=-468/129, 5-13=0/334, 6-13=-596/104,
7-13=-55/2322, 7-12=-1804/164
NOTES
Job Truss Truss Type Qty Ply
5
22
30 23
24
29 W4 T2
12 4 6
7
T1
W3 W3
W2 W5 7
13
3 W6
28 B1 B2
W1 8
T3
2 W7
14 25
HW1 3.5 12 W8 26
1 12 9 10
B3
27
Scale = 1:74.6
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.88 Vert(LL) -0.33 12-13 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.99 Vert(CT) -0.78 12-13 >519 180
TCDL 10.0 Rep Stress Incr YES WB 0.91 Horz(CT) 0.38 11 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 197 lb FT = 20%
NOTES
1) Unbalanced roof live loads have been considered for this
design.
Job Truss Truss Type Qty Ply
5
17
23 18
22 W4 19
T2
4 6
12
7
T1
W3 W3
W2 W5 7
11 20
3 W6 T3
21 W1 B1 B1
8
2 W7
12
HW1 3.5 10 W8
1 12
9
2x4
Scale = 1:65.7
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.85 Vert(LL) -0.35 10-11 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.82 Vert(CT) -0.85 10-11 >479 180
TCDL 10.0 Rep Stress Incr YES WB 0.93 Horz(CT) 0.47 9 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 177 lb FT = 20%
6
22
5
21 T2 23
20 W5 24
T3
W4 7
4 W6
B2
W7 8
3 B3
W2 12
13 25
T1 W8 T4
B4
W1 W3 9
19 W9
3.5 11 W10
2 12
1 HW1
B1 14 10
15
2x4
Scale = 1:67.7
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.90 Vert(LL) -0.34 11-12 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.83 Vert(CT) -0.81 11-12 >499 180
TCDL 10.0 Rep Stress Incr YES WB 0.97 Horz(CT) 0.37 10 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 202 lb FT = 20%
25 T2 267
24 27
W6
5
4 W4 T3
B3
8
W2 W3 W7
3 T1
12 W8
W5 B4
W1 9
2 11 HW2 10
1 HW1
B1
O1
B2 13
16 28 15 29 14
1.5x4
Scale = 1:70.6
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.79 Vert(LL) -0.43 14-16 >947 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.85 Vert(CT) -0.78 14-16 >521 180
TCDL 10.0 Rep Stress Incr YES WB 0.76 Horz(CT) 0.37 10 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 202 lb FT = 20%
21 T2 22
20 23
5 7
4 W4 T3
W2 W3 W3 W2
3 T1 8
W1 W1
2 9
1 HW1 HW1
B1 B2
13 24 25 12 11 26 27 10
Scale = 1:68.1
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.70 Vert(LL) -0.32 11-13 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.95 Vert(CT) -0.58 11-13 >706 180
TCDL 10.0 Rep Stress Incr YES WB 0.51 Horz(CT) 0.10 9 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 185 lb FT = 20%
11
10 12
T2
429 13
43
8 14
67 ST8 T3
15
ST7 ST7
5 ST6 ST6 16
ST5 ST5
4 17
T1 ST4 ST4
3 ST3 ST3 18
ST2 ST2
ST1 ST1
2 19
1 HW1 HW1
B1 B2
Scale = 1:64.3
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.08 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.08 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.17 Horz(CT) 0.00 19 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 237 lb FT = 20%
LUMBER 3) Truss designed for wind loads in the plane of the truss
TOP CHORD 2x4 SP No.2 only. For studs exposed to wind (normal to the face),
BOT CHORD 2x4 SP No.2 see Standard Industry Gable End Details as applicable,
OTHERS 2x4 SP No.3 or consult qualified building designer as per ANSI/TPI 1.
WEDGE Left: 2x4 SP No.3 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Right: 2x4 SP No.3 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
BRACING Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
TOP CHORD Structural wood sheathing directly applied or 5) Unbalanced snow loads have been considered for this
6-0-0 oc purlins. design.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc 6) This truss has been designed for greater of min roof live
bracing. load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
WEBS 1 Row at midpt 11-27, 10-29, 12-26 overhangs non-concurrent with other live loads.
MiTek recommends that Stabilizers and 7) All plates are 1.5x4 MT20 unless otherwise indicated.
required cross bracing be installed during 8) Gable requires continuous bottom chord bearing.
truss erection, in accordance with Stabilizer 9) Gable studs spaced at 2-0-0 oc.
Installation guide. 10) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
REACTIONS All bearings 34-0-0.
11) * This truss has been designed for a live load of 20.0psf
(lb) - Max Horiz 2=161 (LC 15), 36=161 (LC 15)
on the bottom chord in all areas where a rectangle
Max Uplift All uplift 100 (lb) or less at joint(s) 3-06-00 tall by 2-00-00 wide will fit between the bottom
20, 21, 22, 23, 24, 25, 26, 29, 30, chord and any other members.
31, 32, 33, 34, 35 12) Provide mechanical connection (by others) of truss to
Max Grav All reactions 250 (lb) or less at joint bearing plate capable of withstanding 100 lb uplift at joint
(s) 2, 19, 20, 21, 22, 23, 24, 25, 26, (s) 29, 30, 31, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20.
27, 29, 30, 31, 32, 33, 34, 35, 36, 13) This truss is designed in accordance with the 2018
39 International Residential Code sections R502.11.1 and
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 R802.10.2 and referenced standard ANSI/TPI 1.
(lb) or less except when shown.
LOAD CASE(S) Standard
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=34ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-6-5, Exterior(2N) 2-6-5 to 17-0-0, Corner(3R) 17-0-0 to
20-4-13, Exterior(2N) 20-4-13 to 34-0-0 zone; cantilever
left and right exposed ; end vertical left exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
Job Truss Truss Type Qty Ply
18 19
12
7 17 20
T1 W2 W2 T1
3 5
W1 W1
2 6
1 HW1 HW1 7
B1 B1
10 21 9 22 8
Scale = 1:58.4
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.89 Vert(LL) -0.13 8-10 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.74 Vert(CT) -0.20 8-10 >999 180
TCDL 10.0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.05 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 120 lb FT = 20%
LUMBER 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.1 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 4) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
5) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied. overhangs non-concurrent with other live loads.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
6) This truss has been designed for a 10.0 psf bottom
bracing.
chord live load nonconcurrent with any other live loads.
MiTek recommends that Stabilizers and 7) * This truss has been designed for a live load of 20.0psf
required cross bracing be installed during on the bottom chord in all areas where a rectangle
truss erection, in accordance with Stabilizer 3-06-00 tall by 2-00-00 wide will fit between the bottom
Installation guide. chord and any other members, with BCDL = 10.0psf.
8) Provide mechanical connection (by others) of truss to
REACTIONS (lb/size) 2=894/0-3-8, (min. 0-1-8),
bearing plate capable of withstanding 2 lb uplift at joint 2
6=894/0-3-8, (min. 0-1-8)
and 2 lb uplift at joint 6.
Max Horiz 2=117 (LC 15)
9) This truss is designed in accordance with the 2018
Max Uplift 2=-2 (LC 16), 6=-2 (LC 16)
International Residential Code sections R502.11.1 and
Max Grav 2=1115 (LC 28), 6=1115 (LC 29) R802.10.2 and referenced standard ANSI/TPI 1.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 LOAD CASE(S) Standard
(lb) or less except when shown.
TOP CHORD 2-3=-1658/49, 3-17=-1394/22,
17-18=-1293/25, 4-18=-1273/48,
4-19=-1273/48, 19-20=-1293/25,
5-20=-1395/22, 5-6=-1659/49
BOT CHORD 2-10=0/1494, 10-21=0/929, 9-21=0/929,
9-22=0/929, 8-22=0/929, 6-8=0/1406
WEBS 4-8=0/547, 5-8=-402/114, 4-10=0/546,
3-10=-402/114
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
2-1-8, Interior (1) 2-1-8 to 12-0-0, Exterior(2R) 12-0-0 to
15-0-0, Interior (1) 15-0-0 to 24-10-8 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
Job Truss Truss Type Qty Ply
17 18
12
7 16 19
W2 W2 T2
T1
3 5
W1 W1
2 6
1 HW1 HW1
B1 B1
9 20 8 21 7
Scale = 1:54.8
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.89 Vert(LL) -0.13 7-9 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.74 Vert(CT) -0.20 7-9 >999 180
TCDL 10.0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.05 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 118 lb FT = 20%
LUMBER 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.1 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 4) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
5) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied. overhangs non-concurrent with other live loads.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
6) This truss has been designed for a 10.0 psf bottom
bracing.
chord live load nonconcurrent with any other live loads.
MiTek recommends that Stabilizers and 7) * This truss has been designed for a live load of 20.0psf
required cross bracing be installed during on the bottom chord in all areas where a rectangle
truss erection, in accordance with Stabilizer 3-06-00 tall by 2-00-00 wide will fit between the bottom
Installation guide. chord and any other members, with BCDL = 10.0psf.
8) Provide mechanical connection (by others) of truss to
REACTIONS (lb/size) 2=895/0-3-8, (min. 0-1-8),
bearing plate capable of withstanding 2 lb uplift at joint 2.
6=849/0-3-8, (min. 0-1-8)
9) This truss is designed in accordance with the 2018
Max Horiz 2=115 (LC 15)
International Residential Code sections R502.11.1 and
Max Uplift 2=-2 (LC 16) R802.10.2 and referenced standard ANSI/TPI 1.
Max Grav 2=1116 (LC 28), 6=1068 (LC 29)
LOAD CASE(S) Standard
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-3=-1660/49, 3-16=-1396/22,
16-17=-1294/25, 4-17=-1274/48,
4-18=-1277/50, 18-19=-1296/27,
5-19=-1398/24, 5-6=-1664/52
BOT CHORD 2-9=-14/1490, 9-20=0/926, 8-20=0/926,
8-21=0/926, 7-21=0/926, 6-7=-7/1414
WEBS 4-7=0/550, 5-7=-407/115, 4-9=0/546,
3-9=-402/114
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
2-1-8, Interior (1) 2-1-8 to 12-0-0, Exterior(2R) 12-0-0 to
15-0-0, Interior (1) 15-0-0 to 24-0-0 zone; cantilever left
and right exposed ; end vertical left exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
Job Truss Truss Type Qty Ply
7 9
12
7 346 1035
5 T1 ST6 T1 11
ST5 ST5
4 ST4 ST4 12
ST3 ST3
3 13
ST2 ST2
2 ST1 ST1 14
1 HW1 HW1 15
B1 B1
Scale = 1:52.8
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.13 Horz(CT) 0.00 14 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 145 lb FT = 20%
LUMBER 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.2 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
OTHERS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 5) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
6) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied or overhangs non-concurrent with other live loads.
6-0-0 oc purlins.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
8) Gable requires continuous bottom chord bearing.
bracing.
9) Gable studs spaced at 2-0-0 oc.
MiTek recommends that Stabilizers and 10) This truss has been designed for a 10.0 psf bottom
required cross bracing be installed during chord live load nonconcurrent with any other live loads.
truss erection, in accordance with Stabilizer 11) * This truss has been designed for a live load of 20.0psf
Installation guide. on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
REACTIONS All bearings 24-0-0.
chord and any other members.
(lb) - Max Horiz 2=-117 (LC 14), 27=-117 (LC 14)
12) Provide mechanical connection (by others) of truss to
Max Uplift All uplift 100 (lb) or less at joint(s) bearing plate capable of withstanding 100 lb uplift at joint
16, 17, 18, 19, 20, 22, 23, 24, 25, (s) 22, 23, 24, 25, 26, 20, 19, 18, 17, 16.
26
13) This truss is designed in accordance with the 2018
Max Grav All reactions 250 (lb) or less at joint International Residential Code sections R502.11.1 and
(s) 2, 14, 16, 17, 18, 19, 20, 21, 22, R802.10.2 and referenced standard ANSI/TPI 1.
23, 24, 25, 26, 27, 31
LOAD CASE(S) Standard
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-0-0, Exterior(2N) 2-0-0 to 12-0-0, Corner(3R) 12-0-0 to
15-0-0, Exterior(2N) 15-0-0 to 24-10-8 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
Job Truss Truss Type Qty Ply
16 17
15 18
T1 W2 T1
3 5
W1 W1
2 6
HW1 HW1
1 B1 7
19 8 20
Scale = 1:49.8
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.49 Vert(LL) 0.19 8-14 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.84 Vert(CT) -0.28 8-11 >870 180
TCDL 10.0 Rep Stress Incr YES WB 0.28 Horz(CT) 0.03 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 95 lb FT = 20%
LUMBER 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.2 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 4) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
5) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied or overhangs non-concurrent with other live loads.
5-2-7 oc purlins.
6) This truss has been designed for a 10.0 psf bottom
BOT CHORD Rigid ceiling directly applied or 8-10-3 oc
chord live load nonconcurrent with any other live loads.
bracing.
7) * This truss has been designed for a live load of 20.0psf
MiTek recommends that Stabilizers and on the bottom chord in all areas where a rectangle
required cross bracing be installed during 3-06-00 tall by 2-00-00 wide will fit between the bottom
truss erection, in accordance with Stabilizer chord and any other members.
Installation guide. 8) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 161 lb uplift at joint
REACTIONS (lb/size) 2=752/0-3-0, (min. 0-1-8),
2 and 161 lb uplift at joint 6.
6=752/0-3-0, (min. 0-1-8)
9) This truss is designed in accordance with the 2018
Max Horiz 2=-99 (LC 14)
International Residential Code sections R502.11.1 and
Max Uplift 2=-161 (LC 16), 6=-161 (LC 16) R802.10.2 and referenced standard ANSI/TPI 1.
Max Grav 2=852 (LC 2), 6=853 (LC 2)
LOAD CASE(S) Standard
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-3=-1171/498, 3-15=-886/435,
15-16=-815/446, 4-16=-800/465,
4-17=-800/465, 17-18=-815/446,
5-18=-886/435, 5-6=-1171/498
BOT CHORD 2-19=-392/969, 8-19=-392/969,
8-20=-393/969, 6-20=-393/969
WEBS 4-8=-397/559, 5-8=-346/141, 3-8=-346/141
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
2-1-8, Interior (1) 2-1-8 to 10-0-0, Exterior(2R) 10-0-0 to
13-0-0, Interior (1) 13-0-0 to 20-10-8 zone; cantilever left
and right exposed ; end vertical left and right exposed;
porch left and right exposed;C-C for members and forces
& MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
Job Truss Truss Type Qty Ply
6 8
305 931
T1 ST5 T1
4 ST4 ST4 10
ST3 ST3
3 11
ST2 ST2
ST1 ST1
2 12
HW1 HW1
1 B1 13
Scale = 1:48.3
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 12 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 113 lb FT = 20%
LUMBER 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.2 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
OTHERS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 5) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
6) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied or overhangs non-concurrent with other live loads.
6-0-0 oc purlins.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
8) Gable requires continuous bottom chord bearing.
bracing.
9) Gable studs spaced at 2-0-0 oc.
MiTek recommends that Stabilizers and 10) This truss has been designed for a 10.0 psf bottom
required cross bracing be installed during chord live load nonconcurrent with any other live loads.
truss erection, in accordance with Stabilizer 11) * This truss has been designed for a live load of 20.0psf
Installation guide. on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
REACTIONS All bearings 20-0-0.
chord and any other members.
(lb) - Max Horiz 2=-99 (LC 14), 23=-99 (LC 14)
12) Provide mechanical connection (by others) of truss to
Max Uplift All uplift 100 (lb) or less at joint(s) bearing plate capable of withstanding 100 lb uplift at joint
14, 15, 16, 17, 19, 20, 21, 22 (s) 19, 20, 21, 22, 17, 16, 15, 14.
Max Grav All reactions 250 (lb) or less at joint
13) This truss is designed in accordance with the 2018
(s) 2, 12, 14, 15, 16, 17, 18, 19, 20,
International Residential Code sections R502.11.1 and
21, 22, 23, 27
R802.10.2 and referenced standard ANSI/TPI 1.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
LOAD CASE(S) Standard
(lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-0-0, Exterior(2N) 2-0-0 to 10-0-0, Corner(3R) 10-0-0 to
13-0-0, Exterior(2N) 13-0-0 to 20-10-8 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
Job Truss Truss Type Qty Ply
16 17
T2
153 518
T1
19
ST3
ST2 ST2 6
2
14
12 W1
7 ST1
1 B1
7
Scale = 1:46.7
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.41 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.17 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.17 Horiz(TL) 0.00 7 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 89 lb FT = 20%
4x4 =
14 15
T2
132 T1 ST2 4 16
17
1.5x4
Scale = 1:42.1
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.60 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.34 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.11 Horiz(TL) 0.01 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 73 lb FT = 20%
4x4 =
13 T2 14
T1 ST2
2 4
12 15
12 ST1 ST1
7
5
W1
1 B1
6
3x6
Scale = 1:37.6
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.42 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.12 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.08 Horiz(TL) 0.00 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 57 lb FT = 20%
4x4 =
T1 ST1 T1
12
7
9 10
3
1 B1
Scale = 1:34.9
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.85 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.74 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.15 Horiz(TL) 0.01 4 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 39 lb FT = 20%
4x4 =
12 T1 ST1 T1
7
B1
1 3
Scale = 1:33.2
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.36 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.37 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.07 Horiz(TL) 0.00 3 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 25 lb FT = 20%
LUMBER 6) This truss has been designed for a 10.0 psf bottom
TOP CHORD 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
BOT CHORD 2x4 SP No.3 7) * This truss has been designed for a live load of 20.0psf
OTHERS 2x4 SP No.3 on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
BRACING
chord and any other members.
TOP CHORD Structural wood sheathing directly applied or
8) Provide mechanical connection (by others) of truss to
7-6-7 oc purlins.
bearing plate capable of withstanding 3 lb uplift at joint 1
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
and 3 lb uplift at joint 3.
bracing.
9) This truss is designed in accordance with the 2018
MiTek recommends that Stabilizers and International Residential Code sections R502.11.1 and
required cross bracing be installed during R802.10.2 and referenced standard ANSI/TPI 1.
truss erection, in accordance with Stabilizer
LOAD CASE(S) Standard
Installation guide.
3x4 =
12
7 2
T1 T1
B1
1 3
Scale = 1:31.4
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.16 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.15 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) 0.00 3 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 10 lb FT = 20%
4x4 =
3
15 16
13 ST1 ST1 18
12
7
1 B1 5
Scale = 1:43.9
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.65 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.29 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.25 Horiz(TL) 0.00 5 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 77 lb FT = 20%
4x4 =
15T1 T1
16
ST2
2 4
14 17
13 18
12 ST1 ST1
7
1 B1 5
Scale = 1:39.4
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.43 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.11 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.10 Horiz(TL) 0.00 5 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 59 lb FT = 20%
LUMBER 6) This truss has been designed for a 10.0 psf bottom
TOP CHORD 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
BOT CHORD 2x4 SP No.2 7) * This truss has been designed for a live load of 20.0psf
OTHERS 2x4 SP No.3 on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
BRACING
chord and any other members.
TOP CHORD Structural wood sheathing directly applied or
8) Provide mechanical connection (by others) of truss to
6-0-0 oc purlins.
bearing plate capable of withstanding 100 lb uplift at joint
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
(s) 8, 6.
bracing.
9) This truss is designed in accordance with the 2018
MiTek recommends that Stabilizers and International Residential Code sections R502.11.1 and
required cross bracing be installed during R802.10.2 and referenced standard ANSI/TPI 1.
truss erection, in accordance with Stabilizer
LOAD CASE(S) Standard
Installation guide.
4x4 =
T1 ST1 T1
12
7
9 10
1 B1 3
Scale = 1:34.9
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.86 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.72 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.18 Horiz(TL) 0.01 4 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 39 lb FT = 20%
1.5x4
2
12
4 7T1 W1
6 B1
1 3
1.5x4
Scale = 1:23.9
Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.53 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.64 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) 0.01 3 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 15 lb FT = 20%
LUMBER 7) This truss has been designed for a 10.0 psf bottom
TOP CHORD 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
BOT CHORD 2x4 SP No.3 8) * This truss has been designed for a live load of 20.0psf
WEBS 2x4 SP No.3 on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
BRACING
chord and any other members.
TOP CHORD Structural wood sheathing directly applied or
9) Provide mechanical connection (by others) of truss to
4-10-14 oc purlins, except end verticals.
bearing plate capable of withstanding 2 lb uplift at joint 3.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
10) This truss is designed in accordance with the 2018
bracing.
International Residential Code sections R502.11.1 and
MiTek recommends that Stabilizers and R802.10.2 and referenced standard ANSI/TPI 1.
required cross bracing be installed during LOAD CASE(S) Standard
truss erection, in accordance with Stabilizer