0% found this document useful (0 votes)
42 views

Engineering Drawing Report

This document provides information about a common supported gable truss with the designation T01G. It includes details like the truss type, number of plies, loading information, reactions, member forces, bracing requirements and notes. Specifically, it summarizes that the truss is a 1-ply common supported gable truss to support a roof with 20 psf live load and other loading conditions. It also lists maximum member forces and reactions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
42 views

Engineering Drawing Report

This document provides information about a common supported gable truss with the designation T01G. It includes details like the truss type, number of plies, loading information, reactions, member forces, bracing requirements and notes. Specifically, it summarizes that the truss is a 1-ply common supported gable truss to support a roof with 20 psf live load and other loading conditions. It also lists maximum member forces and reactions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Job Truss Truss Type Qty Ply

B30812 Gardner T01 Common 6 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:27 Page: 1
ID:R2?Ni0alXCP2sUomKJ242bzNNfs-_ddQB_I6DadZAwwQF_CKYOmF2a06wJaB23CZd_zNIA?

23 T2 T2
24
22 25

5 7
4 W4 8

W2 W3 W3 W2
3 T1 T1 9

W1 W1
2 10
1 HW1
B1 B2
HW1 11
15 26 27 14 13 28 29 12

Scale = 1:71.7

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.70 Vert(LL) -0.32 13-15 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.95 Vert(CT) -0.58 13-15 >706 180
TCDL 10.0 Rep Stress Incr YES WB 0.51 Horz(CT) 0.10 10 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 187 lb FT = 20%

LUMBER 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)


TOP CHORD 2x4 SP No.2 Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
BOT CHORD 2x4 SP No.2 *Except* B2:2x4 SP No.1 B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed;
WEBS 2x4 SP No.3 MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
WEDGE Left: 2x4 SP No.3 2-6-5, Interior (1) 2-6-5 to 17-0-0, Exterior(2R) 17-0-0 to
Right: 2x4 SP No.3 20-4-13, Interior (1) 20-4-13 to 34-10-8 zone; cantilever
left and right exposed ; end vertical left and right
BRACING exposed;C-C for members and forces & MWFRS for
TOP CHORD Structural wood sheathing directly applied or reactions shown; Lumber DOL=1.60 plate grip
3-1-11 oc purlins. DOL=1.60
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
bracing, Except: Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
10-0-0 oc bracing: 10-12. DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 1 Row at midpt 7-13, 5-13 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
MiTek recommends that Stabilizers and 4) Unbalanced snow loads have been considered for this
required cross bracing be installed during design.
truss erection, in accordance with Stabilizer 5) This truss has been designed for greater of min roof live
Installation guide. load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
overhangs non-concurrent with other live loads.
REACTIONS (lb/size) 2=1248/0-3-8, (min. 0-1-14), 6) This truss has been designed for a 10.0 psf bottom
10=1248/0-3-8, (min. 0-1-14) chord live load nonconcurrent with any other live loads.
Max Horiz 2=163 (LC 15) 7) * This truss has been designed for a live load of 20.0psf
Max Grav 2=1582 (LC 28), 10=1582 (LC 29) on the bottom chord in all areas where a rectangle
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 3-06-00 tall by 2-00-00 wide will fit between the bottom
(lb) or less except when shown. chord and any other members, with BCDL = 10.0psf.
TOP CHORD 2-3=-2502/12, 3-4=-2355/3, 4-5=-2212/24, 8) This truss is designed in accordance with the 2018
5-22=-1629/54, 22-23=-1548/70, International Residential Code sections R502.11.1 and
6-23=-1538/90, 6-24=-1538/90, R802.10.2 and referenced standard ANSI/TPI 1.
24-25=-1548/70, 7-25=-1629/54, LOAD CASE(S) Standard
7-8=-2212/24, 8-9=-2355/3, 9-10=-2503/12
BOT CHORD 2-15=0/2213, 15-26=0/1854, 26-27=0/1854,
14-27=0/1854, 13-14=0/1854, 13-28=0/1755,
28-29=0/1755, 12-29=0/1755, 10-12=0/2094
WEBS 6-13=0/1246, 7-13=-656/91, 7-12=0/480,
5-13=-656/91, 5-15=0/480
NOTES
1) Unbalanced roof live loads have been considered for this
design.
Job Truss Truss Type Qty Ply

B30812 Gardner T01G Common Supported Gable 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:27 Page: 1
ID:VCxUQyzq_1RWiOFwB1daLLzNNfM-SpBpOKJk_tlQo4VcohjZ4cJZd_Z4fr7KHjy69QzNIA_

11

10 12

T2 T2
449 13
45
8 14

67 ST8 1516
ST7 ST7
5 ST6 ST6 17
ST5 ST5
4 18
T1 ST4 ST4 T1
3 ST3 ST3 19
ST2 ST2
ST1 ST1
2 20
1 HW1 HW1 21
B1 B2

Scale = 1:64.3

Plate Offsets (X, Y): [2:0-3-8,Edge], [20:0-3-8,Edge]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.07 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.07 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.17 Horz(CT) 0.00 20 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 239 lb FT = 20%

LUMBER 3) Truss designed for wind loads in the plane of the truss
TOP CHORD 2x4 SP No.2 only. For studs exposed to wind (normal to the face),
BOT CHORD 2x4 SP No.2 see Standard Industry Gable End Details as applicable,
OTHERS 2x4 SP No.3 or consult qualified building designer as per ANSI/TPI 1.
WEDGE Left: 2x4 SP No.3 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Right: 2x4 SP No.3 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
BRACING Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
TOP CHORD Structural wood sheathing directly applied or 5) Unbalanced snow loads have been considered for this
6-0-0 oc purlins. design.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc 6) This truss has been designed for greater of min roof live
bracing. load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
WEBS 1 Row at midpt 11-29, 10-31, 12-28 overhangs non-concurrent with other live loads.
MiTek recommends that Stabilizers and 7) All plates are 1.5x4 MT20 unless otherwise indicated.
required cross bracing be installed during 8) Gable requires continuous bottom chord bearing.
truss erection, in accordance with Stabilizer 9) Gable studs spaced at 2-0-0 oc.
Installation guide. 10) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
REACTIONS All bearings 34-0-0.
11) * This truss has been designed for a live load of 20.0psf
(lb) - Max Horiz 2=163 (LC 15), 38=163 (LC 15)
on the bottom chord in all areas where a rectangle
Max Uplift All uplift 100 (lb) or less at joint(s) 3-06-00 tall by 2-00-00 wide will fit between the bottom
22, 23, 24, 25, 26, 27, 28, 31, 32, chord and any other members.
33, 34, 35, 36, 37 12) Provide mechanical connection (by others) of truss to
Max Grav All reactions 250 (lb) or less at joint bearing plate capable of withstanding 100 lb uplift at joint
(s) 2, 20, 22, 23, 24, 25, 26, 27, 28, (s) 31, 32, 33, 34, 35, 36, 37, 28, 27, 26, 25, 24, 23, 22.
29, 31, 32, 33, 34, 35, 36, 37, 38, 13) This truss is designed in accordance with the 2018
41 International Residential Code sections R502.11.1 and
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 R802.10.2 and referenced standard ANSI/TPI 1.
(lb) or less except when shown.
LOAD CASE(S) Standard
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=34ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-6-5, Exterior(2N) 2-6-5 to 17-0-0, Corner(3R) 17-0-0 to
20-4-13, Exterior(2N) 20-4-13 to 34-10-8 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
Job Truss Truss Type Qty Ply

B30812 Gardner T02G Roof Special Structural Gable 1 1 Job Reference (optional)
K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:27 Page: 1
ID:h8hwR9jjO4Fj8w_rq2k6sQzNNeO-SpBpOKJk_tlQo4VcohjZ4cJNR_MyffoKHjy69QzNIA_

4
32

42 33
34
41 T2
3 5
T1 W4

W2 W3 W3 W5
2
W6 ST1 T3 7
ST2
W1 35
W7 ST4W8 ST5 36
1 ST3 ST6 8 9
HW1
B1 B2
16 37 38 15 14 39 40 13

Scale = 1:72.8

Plate Offsets (X, Y): [13:0-2-8,0-2-0], [21:0-1-10,0-0-12]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.85 Vert(LL) -0.29 15-16 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.91 Vert(CT) -0.52 15-16 >778 180
TCDL 10.0 Rep Stress Incr YES WB 0.96 Horz(CT) 0.06 12 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 229 lb FT = 20%

LUMBER 1) Unbalanced roof live loads have been considered for this
TOP CHORD 2x4 SP No.2 design.
BOT CHORD 2x4 SP No.1 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
WEBS 2x4 SP No.3 Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
OTHERS 2x4 SP No.3 B=45ft; L=40ft; eave=5ft; Cat. II; Exp B; Enclosed;
WEDGE Left: 2x4 SP No.3 MWFRS (directional) and C-C Exterior(2E) 0-0-0 to
4-0-11, Interior (1) 4-0-11 to 17-0-0, Exterior(2R) 17-0-0
BRACING
to 21-0-0, Interior (1) 21-0-0 to 40-10-8 zone; cantilever
TOP CHORD Structural wood sheathing directly applied or left and right exposed ; end vertical right exposed;C-C
2-2-0 oc purlins. for members and forces & MWFRS for reactions shown;
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc Lumber DOL=1.60 plate grip DOL=1.60
bracing. 3) Truss designed for wind loads in the plane of the truss
WEBS 1 Row at midpt 3-15, 5-15 only. For studs exposed to wind (normal to the face),
MiTek recommends that Stabilizers and see Standard Industry Gable End Details as applicable,
required cross bracing be installed during or consult qualified building designer as per ANSI/TPI 1.
truss erection, in accordance with Stabilizer 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Installation guide. Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
REACTIONS All bearings 6-3-8. except 1=0-3-8 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
(lb) - Max Horiz 1=-159 (LC 14) 5) Unbalanced snow loads have been considered for this
Max Uplift All uplift 100 (lb) or less at joint(s) design.
8, 29 except 11=-119 (LC 2) 6) This truss has been designed for greater of min roof live
Max Grav All reactions 250 (lb) or less at joint load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
(s) 8, 10, 11, 29 except 1=1478 (LC overhangs non-concurrent with other live loads.
28), 12=2053 (LC 29) 7) All plates are 1.5x4 MT20 unless otherwise indicated.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 8) Gable studs spaced at 2-0-0 oc.
(lb) or less except when shown. 9) This truss has been designed for a 10.0 psf bottom
TOP CHORD 4-32=-1363/191, 32-33=-1428/171, chord live load nonconcurrent with any other live loads.
33-34=-1447/166, 5-34=-1513/165, 10) * This truss has been designed for a live load of 20.0psf
5-6=-1921/166, 6-7=-1810/109, on the bottom chord in all areas where a rectangle
7-35=-22/651, 35-36=-33/595, 8-36=-41/576, 3-06-00 tall by 2-00-00 wide will fit between the bottom
1-2=-2406/163, 2-3=-2255/163, chord and any other members, with BCDL = 10.0psf.
3-41=-1510/158, 41-42=-1444/170, 11) Provide mechanical connection (by others) of truss to
4-42=-1418/194 bearing plate capable of withstanding 100 lb uplift at joint
BOT CHORD 1-16=-73/2133, 16-37=-10/1759, (s) 8, 8 except (jt=lb) 11=118.
37-38=-10/1759, 15-38=-10/1759, 12) This truss is designed in accordance with the 2018
14-15=0/1533, 14-39=0/1533, 39-40=0/1533, International Residential Code sections R502.11.1 and
13-40=0/1533, 12-13=-561/69, R802.10.2 and referenced standard ANSI/TPI 1.
11-12=-561/69, 10-11=-561/69, 8-10=-561/69 LOAD CASE(S) Standard
WEBS 3-16=0/493, 3-15=-660/145, 4-15=-58/1119,
5-15=-468/129, 5-13=0/334, 6-13=-596/104,
7-13=-55/2322, 7-12=-1804/164
NOTES
Job Truss Truss Type Qty Ply

B30812 Gardner T03 Roof Special 8 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:28 Page: 1
ID:?ZjGAodlk7h4eSDFjIaiOEzNNdD-w?lBbfJMlBtHPD4oMPFodpsYkOhxO6oUWNhggtzNI9z

5
22

30 23
24
29 W4 T2
12 4 6
7
T1
W3 W3
W2 W5 7
13
3 W6
28 B1 B2
W1 8
T3
2 W7
14 25
HW1 3.5 12 W8 26
1 12 9 10
B3
27

Scale = 1:74.6

Plate Offsets (X, Y): [1:0-1-11,0-3-0], [11:0-3-4,0-2-8], [12:0-5-11,0-2-0]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.88 Vert(LL) -0.33 12-13 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.99 Vert(CT) -0.78 12-13 >519 180
TCDL 10.0 Rep Stress Incr YES WB 0.91 Horz(CT) 0.38 11 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 197 lb FT = 20%

LUMBER 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)


TOP CHORD 2x4 SP No.2 *Except* T3:2x4 SP No.1 Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
BOT CHORD 2x4 SP No.2 *Except* B2:2x4 SP No.1 B=45ft; L=40ft; eave=5ft; Cat. II; Exp B; Enclosed;
WEBS 2x4 SP No.3 *Except* W7:2x4 SP No.2 MWFRS (directional) and C-C Exterior(2E) 0-0-0 to
SLIDER Left 2x4 SP No.3 -- 2-5-8 4-0-0, Interior (1) 4-0-0 to 17-0-0, Exterior(2R) 17-0-0 to
21-0-0, Interior (1) 21-0-0 to 40-10-8 zone; cantilever left
BRACING and right exposed ; end vertical right exposed; porch
TOP CHORD Structural wood sheathing directly applied or right exposed;C-C for members and forces & MWFRS
2-1-0 oc purlins. for reactions shown; Lumber DOL=1.60 plate grip
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc DOL=1.60
bracing. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
MiTek recommends that Stabilizers and Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
required cross bracing be installed during DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
truss erection, in accordance with Stabilizer Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
Installation guide. 4) Unbalanced snow loads have been considered for this
design.
REACTIONS (lb/size) 1=1067/0-3-8, (min. 0-1-8), 5) This truss has been designed for greater of min roof live
9=-406/0-3-0, (min. 0-1-8), load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
11=2216/0-3-8, (min. 0-2-15) overhangs non-concurrent with other live loads.
Max Horiz 1=-159 (LC 14) 6) This truss has been designed for a 10.0 psf bottom
Max Uplift 9=-475 (LC 28) chord live load nonconcurrent with any other live loads.
Max Grav 1=1206 (LC 2), 9=-89 (LC 16), 7) * This truss has been designed for a live load of 20.0psf
11=2504 (LC 2) on the bottom chord in all areas where a rectangle
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 3-06-00 tall by 2-00-00 wide will fit between the bottom
(lb) or less except when shown. chord and any other members.
TOP CHORD 5-22=-1921/99, 22-23=-1981/82, 8) Bearing at joint(s) 1 considers parallel to grain value
23-24=-2021/74, 6-24=-2073/67, using ANSI/TPI 1 angle to grain formula. Building
6-7=-1798/119, 7-8=-1711/57, 8-25=-23/2227, designer should verify capacity of bearing surface.
25-26=-29/2151, 9-26=-30/2140, 9) Provide mechanical connection (by others) of truss to
1-2=-1608/18, 2-28=-3306/217, bearing plate capable of withstanding 475 lb uplift at joint
3-28=-3243/222, 3-4=-3025/131, 9.
4-29=-2081/68, 29-30=-2055/70, 10) This truss is designed in accordance with the 2018
5-30=-1981/99 International Residential Code sections R502.11.1 and
BOT CHORD 11-27=-2040/51, 9-27=-2040/51, R802.10.2 and referenced standard ANSI/TPI 1.
1-14=-124/2916, 13-14=0/2503,
LOAD CASE(S) Standard
12-13=0/1959, 11-12=-2270/83
WEBS 3-14=-260/168, 4-14=0/484, 4-13=-733/173,
5-13=0/1690, 6-13=-286/157, 6-12=-534/46,
7-12=-627/104, 8-12=0/3710, 8-11=-1730/162

NOTES
1) Unbalanced roof live loads have been considered for this
design.
Job Truss Truss Type Qty Ply

B30812 Gardner T04 Roof Special 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:28 Page: 1
ID:e7wMFMuoD40Nt?zZSZhttfzNNID-w?lBbfJMlBtHPD4oMPFodpsYBOkcO6UUWNhggtzNI9z

5
17

23 18
22 W4 19
T2
4 6
12
7
T1
W3 W3

W2 W5 7
11 20
3 W6 T3
21 W1 B1 B1
8
2 W7
12
HW1 3.5 10 W8
1 12
9

2x4

Scale = 1:65.7

Plate Offsets (X, Y): [1:0-0-11,0-2-4]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.85 Vert(LL) -0.35 10-11 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.82 Vert(CT) -0.85 10-11 >479 180
TCDL 10.0 Rep Stress Incr YES WB 0.93 Horz(CT) 0.47 9 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 177 lb FT = 20%

LUMBER 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)


TOP CHORD 2x4 SP No.2 *Except* T3:2x4 SP 2400F Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
2.0E, T1:2x4 SP No.1 B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed;
BOT CHORD 2x4 SP No.1 MWFRS (directional) and C-C Exterior(2E) 0-0-0 to
WEBS 2x4 SP No.3 *Except* W7:2x4 SP No.2 3-4-13, Interior (1) 3-4-13 to 17-0-0, Exterior(2R) 17-0-0
SLIDER Left 2x4 SP No.3 -- 2-5-8 to 20-4-13, Interior (1) 20-4-13 to 33-10-4 zone;
cantilever left and right exposed ;C-C for members and
BRACING forces & MWFRS for reactions shown; Lumber
TOP CHORD Structural wood sheathing directly applied or DOL=1.60 plate grip DOL=1.60
2-2-0 oc purlins, except end verticals. 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
bracing. DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
MiTek recommends that Stabilizers and Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
required cross bracing be installed during 4) Unbalanced snow loads have been considered for this
truss erection, in accordance with Stabilizer design.
Installation guide. 5) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
REACTIONS (lb/size) 1=1198/0-3-8, (min. 0-1-8), 6) * This truss has been designed for a live load of 20.0psf
9=1198/0-3-8, (min. 0-1-8) on the bottom chord in all areas where a rectangle
Max Horiz 1=-141 (LC 14) 3-06-00 tall by 2-00-00 wide will fit between the bottom
Max Grav 1=1354 (LC 2), 9=1354 (LC 2) chord and any other members.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 7) Bearing at joint(s) 1, 9 considers parallel to grain value
(lb) or less except when shown. using ANSI/TPI 1 angle to grain formula. Building
TOP CHORD 5-17=-2471/181, 17-18=-2531/165, designer should verify capacity of bearing surface.
18-19=-2552/161, 6-19=-2623/150, 8) This truss is designed in accordance with the 2018
6-7=-3690/247, 7-20=-3384/171, International Residential Code sections R502.11.1 and
8-20=-3453/157, 8-9=-1320/113, R802.10.2 and referenced standard ANSI/TPI 1.
1-2=-1808/38, 2-21=-3779/264, LOAD CASE(S) Standard
3-21=-3734/281, 3-4=-3533/198,
4-22=-2631/142, 22-23=-2560/153,
5-23=-2531/174
BOT CHORD 1-12=-254/3327, 11-12=-138/2982,
10-11=-127/2924
WEBS 4-12=0/458, 4-11=-721/166, 5-11=-69/2244,
6-11=-660/163, 6-10=-2/635,
7-10=-1057/149, 8-10=-99/3116
NOTES
1) Unbalanced roof live loads have been considered for this
design.
Job Truss Truss Type Qty Ply

B30812 Gardner T05 Roof Special 2 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:28 Page: 1
ID:mwnaYzLmqF7iDWEbgB8XHgzNNcI-w?lBbfJMlBtHPD4oMPFodpsXQOkSO5sUWNhggtzNI9z

6
22
5
21 T2 23
20 W5 24
T3
W4 7
4 W6
B2
W7 8
3 B3
W2 12
13 25
T1 W8 T4
B4
W1 W3 9
19 W9
3.5 11 W10
2 12
1 HW1
B1 14 10
15
2x4

Scale = 1:67.7

Plate Offsets (X, Y): [15:0-3-8,0-1-8]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.90 Vert(LL) -0.34 11-12 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.83 Vert(CT) -0.81 11-12 >499 180
TCDL 10.0 Rep Stress Incr YES WB 0.97 Horz(CT) 0.37 10 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 202 lb FT = 20%

LUMBER 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)


TOP CHORD 2x4 SP No.1 *Except* T3:2x4 SP No.2, Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
T4:2x4 SP 2400F 2.0E B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed;
BOT CHORD 2x4 SP No.2 *Except* B2:2x4 SP No.3, MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
B4:2x4 SP No.1 2-6-5, Interior (1) 2-6-5 to 17-0-0, Exterior(2R) 17-0-0 to
WEBS 2x4 SP No.3 *Except* W9:2x4 SP No.2 20-4-13, Interior (1) 20-4-13 to 33-10-4 zone; cantilever
WEDGE Left: 2x4 SP No.3 left and right exposed ; end vertical left exposed;C-C for
members and forces & MWFRS for reactions shown;
BRACING Lumber DOL=1.60 plate grip DOL=1.60
TOP CHORD Structural wood sheathing directly applied, 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
except end verticals. Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
bracing. Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
MiTek recommends that Stabilizers and 4) Unbalanced snow loads have been considered for this
required cross bracing be installed during design.
truss erection, in accordance with Stabilizer 5) This truss has been designed for greater of min roof live
Installation guide. load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
overhangs non-concurrent with other live loads.
REACTIONS (lb/size) 2=1243/0-3-8, (min. 0-1-11), 6) This truss has been designed for a 10.0 psf bottom
10=1198/0-3-8, (min. 0-1-8) chord live load nonconcurrent with any other live loads.
Max Horiz 2=-143 (LC 14) 7) * This truss has been designed for a live load of 20.0psf
Max Grav 2=1407 (LC 2), 10=1353 (LC 2) on the bottom chord in all areas where a rectangle
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 3-06-00 tall by 2-00-00 wide will fit between the bottom
(lb) or less except when shown. chord and any other members.
TOP CHORD 2-19=-2198/114, 3-19=-2037/138, 8) Bearing at joint(s) 10 considers parallel to grain value
3-4=-3092/176, 4-20=-2973/182, using ANSI/TPI 1 angle to grain formula. Building
20-21=-2878/201, 5-21=-2876/206, designer should verify capacity of bearing surface.
5-6=-2583/201, 6-22=-2465/179, 9) This truss is designed in accordance with the 2018
22-23=-2523/164, 23-24=-2546/159, International Residential Code sections R502.11.1 and
7-24=-2616/148, 7-8=-3688/245, R802.10.2 and referenced standard ANSI/TPI 1.
8-25=-3383/169, 9-25=-3452/156, LOAD CASE(S) Standard
9-10=-1320/112
BOT CHORD 2-15=-104/1823, 5-13=-9/421,
12-13=-42/2640, 11-12=-128/2922
WEBS 3-15=-835/153, 13-15=-128/2038,
3-13=0/745, 5-12=-684/149, 6-12=-130/2351,
7-12=-658/165, 7-11=0/639, 8-11=-1056/148,
9-11=-97/3115
NOTES
1) Unbalanced roof live loads have been considered for this
design.
Job Truss Truss Type Qty Ply

B30812 Gardner T06 Roof Special 5 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:28 Page: 1
ID:mjMsFQylqwYTqMdOAPYVsQzNNbV-w?lBbfJMlBtHPD4oMPFodpsZ7Oj7O99UWNhggtzNI9z

25 T2 267
24 27
W6
5
4 W4 T3

B3
8
W2 W3 W7
3 T1
12 W8
W5 B4
W1 9
2 11 HW2 10
1 HW1
B1
O1
B2 13
16 28 15 29 14
1.5x4

Scale = 1:70.6

Plate Offsets (X, Y): [10:0-0-15,0-2-8], [12:0-4-0,0-3-8]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.79 Vert(LL) -0.43 14-16 >947 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.85 Vert(CT) -0.78 14-16 >521 180
TCDL 10.0 Rep Stress Incr YES WB 0.76 Horz(CT) 0.37 10 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 202 lb FT = 20%

LUMBER 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)


TOP CHORD 2x4 SP No.2 *Except* T3:2x4 SP No.1 Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
BOT CHORD 2x4 SP No.1 *Except* B3:2x4 SP No.3, B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed;
B4:2x4 SP 2400F 2.0E MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
WEBS 2x4 SP No.3 *Except* W6:2x4 SP No.2 2-6-5, Interior (1) 2-6-5 to 17-0-0, Exterior(2R) 17-0-0 to
OTHERS 2x4 SP No.3 20-4-13, Interior (1) 20-4-13 to 34-0-0 zone; cantilever
WEDGE Left: 2x4 SP No.3 left and right exposed ; end vertical left exposed;C-C for
SLIDER Right 2x4 SP No.3 -- 1-6-0 members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
BRACING 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD Structural wood sheathing directly applied or Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
2-2-0 oc purlins. DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
bracing. 4) Unbalanced snow loads have been considered for this
WEBS 1 Row at midpt 6-14, 5-14 design.
MiTek recommends that Stabilizers and 5) This truss has been designed for greater of min roof live
required cross bracing be installed during load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
truss erection, in accordance with Stabilizer overhangs non-concurrent with other live loads.
Installation guide. 6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
REACTIONS (lb/size) 2=1249/0-3-8, (min. 0-1-14), 7) * This truss has been designed for a live load of 20.0psf
10=1203/0-3-8, (min. 0-1-8) on the bottom chord in all areas where a rectangle
Max Horiz 2=161 (LC 15) 3-06-00 tall by 2-00-00 wide will fit between the bottom
Max Grav 2=1565 (LC 28), 10=1498 (LC 29) chord and any other members, with BCDL = 10.0psf.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 8) Bearing at joint(s) 10 considers parallel to grain value
(lb) or less except when shown. using ANSI/TPI 1 angle to grain formula. Building
TOP CHORD 2-3=-2477/10, 3-4=-2330/11, 4-5=-2187/22, designer should verify capacity of bearing surface.
5-24=-1584/57, 24-25=-1502/73, 9) This truss is designed in accordance with the 2018
6-25=-1488/93, 6-26=-3324/46, International Residential Code sections R502.11.1 and
7-26=-3334/25, 7-27=-3261/0, 8-27=-3421/0, R802.10.2 and referenced standard ANSI/TPI 1.
8-9=-4144/0, 9-10=-3837/0 LOAD CASE(S) Standard
BOT CHORD 2-16=0/2187, 16-28=0/1821, 15-28=0/1821,
15-29=0/1821, 14-29=0/1821, 7-12=-371/113,
11-12=0/3673, 10-11=0/3636
WEBS 6-12=0/3096, 8-12=-667/87, 6-14=-569/0,
12-14=0/1889, 5-16=0/498, 5-14=-672/89
NOTES
1) Unbalanced roof live loads have been considered for this
design.
Job Truss Truss Type Qty Ply

B30812 Gardner T07 Common 4 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:29 Page: 1
ID:v1E2hIkvlbcOWBXhvriVSwzNNaV-OBJZp?K?WV?81Nf_w6m191OlIn2p7fJdk1RDCJzNI9y

21 T2 22
20 23

5 7
4 W4 T3

W2 W3 W3 W2
3 T1 8

W1 W1
2 9
1 HW1 HW1
B1 B2
13 24 25 12 11 26 27 10

Scale = 1:68.1

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.70 Vert(LL) -0.32 11-13 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.95 Vert(CT) -0.58 11-13 >706 180
TCDL 10.0 Rep Stress Incr YES WB 0.51 Horz(CT) 0.10 9 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 185 lb FT = 20%

LUMBER 2) Wind: ASCE 7-16; Vult=115mph (3-second gust)


TOP CHORD 2x4 SP No.2 Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
BOT CHORD 2x4 SP No.2 *Except* B2:2x4 SP No.1 B=45ft; L=34ft; eave=4ft; Cat. II; Exp B; Enclosed;
WEBS 2x4 SP No.3 MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
WEDGE Left: 2x4 SP No.3 2-6-5, Interior (1) 2-6-5 to 17-0-0, Exterior(2R) 17-0-0 to
Right: 2x4 SP No.3 20-4-13, Interior (1) 20-4-13 to 34-0-0 zone; cantilever
left and right exposed ; end vertical left and right
BRACING exposed;C-C for members and forces & MWFRS for
TOP CHORD Structural wood sheathing directly applied or reactions shown; Lumber DOL=1.60 plate grip
3-1-11 oc purlins. DOL=1.60
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
bracing, Except: Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
10-0-0 oc bracing: 9-10. DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 1 Row at midpt 7-11, 5-11 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
MiTek recommends that Stabilizers and 4) Unbalanced snow loads have been considered for this
required cross bracing be installed during design.
truss erection, in accordance with Stabilizer 5) This truss has been designed for greater of min roof live
Installation guide. load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
overhangs non-concurrent with other live loads.
REACTIONS (lb/size) 2=1249/0-3-8, (min. 0-1-14), 6) This truss has been designed for a 10.0 psf bottom
9=1203/0-3-8, (min. 0-1-13) chord live load nonconcurrent with any other live loads.
Max Horiz 2=161 (LC 15) 7) * This truss has been designed for a live load of 20.0psf
Max Grav 2=1583 (LC 28), 9=1535 (LC 29) on the bottom chord in all areas where a rectangle
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 3-06-00 tall by 2-00-00 wide will fit between the bottom
(lb) or less except when shown. chord and any other members, with BCDL = 10.0psf.
TOP CHORD 2-3=-2503/12, 3-4=-2356/3, 4-5=-2213/24, 8) This truss is designed in accordance with the 2018
5-20=-1630/54, 20-21=-1549/70, International Residential Code sections R502.11.1 and
6-21=-1539/90, 6-22=-1539/91, R802.10.2 and referenced standard ANSI/TPI 1.
22-23=-1548/70, 7-23=-1630/55, LOAD CASE(S) Standard
7-8=-2360/26, 8-9=-2510/15
BOT CHORD 2-13=0/2210, 13-24=0/1851, 24-25=0/1851,
12-25=0/1851, 11-12=0/1851, 11-26=0/1752,
26-27=0/1752, 10-27=0/1752, 9-10=0/2102
WEBS 6-11=0/1247, 7-11=-658/91, 7-10=0/484,
5-11=-656/91, 5-13=0/480
NOTES
1) Unbalanced roof live loads have been considered for this
design.
Job Truss Truss Type Qty Ply

B30812 Gardner T07G Common Supported Gable 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:29 Page: 1
ID:4QweZt3T9B8PsVg4YjC4aqzNNa3-OBJZp?K?WV?81Nf_w6m191Ou_nFP7kcdk1RDCJzNI9y

11

10 12

T2
429 13
43
8 14

67 ST8 T3
15
ST7 ST7
5 ST6 ST6 16
ST5 ST5
4 17
T1 ST4 ST4
3 ST3 ST3 18
ST2 ST2
ST1 ST1
2 19
1 HW1 HW1
B1 B2

Scale = 1:64.3

Plate Offsets (X, Y): [2:0-3-8,Edge], [19:0-3-8,Edge]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.08 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.08 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.17 Horz(CT) 0.00 19 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 237 lb FT = 20%

LUMBER 3) Truss designed for wind loads in the plane of the truss
TOP CHORD 2x4 SP No.2 only. For studs exposed to wind (normal to the face),
BOT CHORD 2x4 SP No.2 see Standard Industry Gable End Details as applicable,
OTHERS 2x4 SP No.3 or consult qualified building designer as per ANSI/TPI 1.
WEDGE Left: 2x4 SP No.3 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Right: 2x4 SP No.3 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
BRACING Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
TOP CHORD Structural wood sheathing directly applied or 5) Unbalanced snow loads have been considered for this
6-0-0 oc purlins. design.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc 6) This truss has been designed for greater of min roof live
bracing. load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
WEBS 1 Row at midpt 11-27, 10-29, 12-26 overhangs non-concurrent with other live loads.
MiTek recommends that Stabilizers and 7) All plates are 1.5x4 MT20 unless otherwise indicated.
required cross bracing be installed during 8) Gable requires continuous bottom chord bearing.
truss erection, in accordance with Stabilizer 9) Gable studs spaced at 2-0-0 oc.
Installation guide. 10) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
REACTIONS All bearings 34-0-0.
11) * This truss has been designed for a live load of 20.0psf
(lb) - Max Horiz 2=161 (LC 15), 36=161 (LC 15)
on the bottom chord in all areas where a rectangle
Max Uplift All uplift 100 (lb) or less at joint(s) 3-06-00 tall by 2-00-00 wide will fit between the bottom
20, 21, 22, 23, 24, 25, 26, 29, 30, chord and any other members.
31, 32, 33, 34, 35 12) Provide mechanical connection (by others) of truss to
Max Grav All reactions 250 (lb) or less at joint bearing plate capable of withstanding 100 lb uplift at joint
(s) 2, 19, 20, 21, 22, 23, 24, 25, 26, (s) 29, 30, 31, 32, 33, 34, 35, 26, 25, 24, 23, 22, 21, 20.
27, 29, 30, 31, 32, 33, 34, 35, 36, 13) This truss is designed in accordance with the 2018
39 International Residential Code sections R502.11.1 and
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 R802.10.2 and referenced standard ANSI/TPI 1.
(lb) or less except when shown.
LOAD CASE(S) Standard
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=34ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-6-5, Exterior(2N) 2-6-5 to 17-0-0, Corner(3R) 17-0-0 to
20-4-13, Exterior(2N) 20-4-13 to 34-0-0 zone; cantilever
left and right exposed ; end vertical left exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
Job Truss Truss Type Qty Ply

B30812 Gardner T08 Common 11 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:29 Page: 1
ID:uLtmxg9kJyXoiLn5PXwPGizNNhi-OBJZp?K?WV?81Nf_w6m191OiKn547jrdk1RDCJzNI9y

18 19
12
7 17 20
T1 W2 W2 T1

3 5

W1 W1

2 6
1 HW1 HW1 7
B1 B1
10 21 9 22 8

Scale = 1:58.4

Plate Offsets (X, Y): [2:0-3-8,Edge], [3:0-0-0,0-0-0], [6:0-3-8,Edge]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.89 Vert(LL) -0.13 8-10 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.74 Vert(CT) -0.20 8-10 >999 180
TCDL 10.0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.05 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 120 lb FT = 20%

LUMBER 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.1 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 4) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
5) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied. overhangs non-concurrent with other live loads.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
6) This truss has been designed for a 10.0 psf bottom
bracing.
chord live load nonconcurrent with any other live loads.
MiTek recommends that Stabilizers and 7) * This truss has been designed for a live load of 20.0psf
required cross bracing be installed during on the bottom chord in all areas where a rectangle
truss erection, in accordance with Stabilizer 3-06-00 tall by 2-00-00 wide will fit between the bottom
Installation guide. chord and any other members, with BCDL = 10.0psf.
8) Provide mechanical connection (by others) of truss to
REACTIONS (lb/size) 2=894/0-3-8, (min. 0-1-8),
bearing plate capable of withstanding 2 lb uplift at joint 2
6=894/0-3-8, (min. 0-1-8)
and 2 lb uplift at joint 6.
Max Horiz 2=117 (LC 15)
9) This truss is designed in accordance with the 2018
Max Uplift 2=-2 (LC 16), 6=-2 (LC 16)
International Residential Code sections R502.11.1 and
Max Grav 2=1115 (LC 28), 6=1115 (LC 29) R802.10.2 and referenced standard ANSI/TPI 1.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 LOAD CASE(S) Standard
(lb) or less except when shown.
TOP CHORD 2-3=-1658/49, 3-17=-1394/22,
17-18=-1293/25, 4-18=-1273/48,
4-19=-1273/48, 19-20=-1293/25,
5-20=-1395/22, 5-6=-1659/49
BOT CHORD 2-10=0/1494, 10-21=0/929, 9-21=0/929,
9-22=0/929, 8-22=0/929, 6-8=0/1406
WEBS 4-8=0/547, 5-8=-402/114, 4-10=0/546,
3-10=-402/114
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
2-1-8, Interior (1) 2-1-8 to 12-0-0, Exterior(2R) 12-0-0 to
15-0-0, Interior (1) 15-0-0 to 24-10-8 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
Job Truss Truss Type Qty Ply

B30812 Gardner T08A Common 3 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:29 Page: 1
ID:c43qkXu?yhD8WjxpUqWiEazNNgl-OBJZp?K?WV?81Nf_w6m191OiKn547jrdk1RDCJzNI9y

17 18
12
7 16 19
W2 W2 T2
T1

3 5

W1 W1

2 6
1 HW1 HW1
B1 B1

9 20 8 21 7

Scale = 1:54.8

Plate Offsets (X, Y): [2:0-3-8,Edge], [6:0-3-8,Edge]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.89 Vert(LL) -0.13 7-9 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.74 Vert(CT) -0.20 7-9 >999 180
TCDL 10.0 Rep Stress Incr YES WB 0.22 Horz(CT) 0.05 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 118 lb FT = 20%

LUMBER 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.1 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 4) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
5) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied. overhangs non-concurrent with other live loads.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
6) This truss has been designed for a 10.0 psf bottom
bracing.
chord live load nonconcurrent with any other live loads.
MiTek recommends that Stabilizers and 7) * This truss has been designed for a live load of 20.0psf
required cross bracing be installed during on the bottom chord in all areas where a rectangle
truss erection, in accordance with Stabilizer 3-06-00 tall by 2-00-00 wide will fit between the bottom
Installation guide. chord and any other members, with BCDL = 10.0psf.
8) Provide mechanical connection (by others) of truss to
REACTIONS (lb/size) 2=895/0-3-8, (min. 0-1-8),
bearing plate capable of withstanding 2 lb uplift at joint 2.
6=849/0-3-8, (min. 0-1-8)
9) This truss is designed in accordance with the 2018
Max Horiz 2=115 (LC 15)
International Residential Code sections R502.11.1 and
Max Uplift 2=-2 (LC 16) R802.10.2 and referenced standard ANSI/TPI 1.
Max Grav 2=1116 (LC 28), 6=1068 (LC 29)
LOAD CASE(S) Standard
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-3=-1660/49, 3-16=-1396/22,
16-17=-1294/25, 4-17=-1274/48,
4-18=-1277/50, 18-19=-1296/27,
5-19=-1398/24, 5-6=-1664/52
BOT CHORD 2-9=-14/1490, 9-20=0/926, 8-20=0/926,
8-21=0/926, 7-21=0/926, 6-7=-7/1414
WEBS 4-7=0/550, 5-7=-407/115, 4-9=0/546,
3-9=-402/114
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
2-1-8, Interior (1) 2-1-8 to 12-0-0, Exterior(2R) 12-0-0 to
15-0-0, Interior (1) 15-0-0 to 24-0-0 zone; cantilever left
and right exposed ; end vertical left exposed;C-C for
members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
Job Truss Truss Type Qty Ply

B30812 Gardner T08G Common Supported Gable 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:29 Page: 1
ID:UJFURGXA0TROw6f2jX_g0FzNNhD-OBJZp?K?WV?81Nf_w6m191OvInGB7kFdk1RDCJzNI9y

7 9

12
7 346 1035

5 T1 ST6 T1 11
ST5 ST5
4 ST4 ST4 12
ST3 ST3
3 13
ST2 ST2

2 ST1 ST1 14
1 HW1 HW1 15
B1 B1

Scale = 1:52.8

Plate Offsets (X, Y): [2:0-3-8,Edge], [14:0-3-8,Edge], [21:0-2-8,0-3-0]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.13 Horz(CT) 0.00 14 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 145 lb FT = 20%

LUMBER 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.2 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
OTHERS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 5) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
6) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied or overhangs non-concurrent with other live loads.
6-0-0 oc purlins.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
8) Gable requires continuous bottom chord bearing.
bracing.
9) Gable studs spaced at 2-0-0 oc.
MiTek recommends that Stabilizers and 10) This truss has been designed for a 10.0 psf bottom
required cross bracing be installed during chord live load nonconcurrent with any other live loads.
truss erection, in accordance with Stabilizer 11) * This truss has been designed for a live load of 20.0psf
Installation guide. on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
REACTIONS All bearings 24-0-0.
chord and any other members.
(lb) - Max Horiz 2=-117 (LC 14), 27=-117 (LC 14)
12) Provide mechanical connection (by others) of truss to
Max Uplift All uplift 100 (lb) or less at joint(s) bearing plate capable of withstanding 100 lb uplift at joint
16, 17, 18, 19, 20, 22, 23, 24, 25, (s) 22, 23, 24, 25, 26, 20, 19, 18, 17, 16.
26
13) This truss is designed in accordance with the 2018
Max Grav All reactions 250 (lb) or less at joint International Residential Code sections R502.11.1 and
(s) 2, 14, 16, 17, 18, 19, 20, 21, 22, R802.10.2 and referenced standard ANSI/TPI 1.
23, 24, 25, 26, 27, 31
LOAD CASE(S) Standard
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-0-0, Exterior(2N) 2-0-0 to 12-0-0, Corner(3R) 12-0-0 to
15-0-0, Exterior(2N) 15-0-0 to 24-10-8 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
Job Truss Truss Type Qty Ply

B30812 Gardner T09 Common 5 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:30 Page: 1
ID:gOIM4TSvsj205FX1tkFLLMzNNZa-sOtx0LLdHo7?fXEBUpHGiExzJBPms98nzhAnllzNI9x

16 17
15 18
T1 W2 T1
3 5

W1 W1

2 6
HW1 HW1
1 B1 7

19 8 20

Scale = 1:49.8

Plate Offsets (X, Y): [2:0-3-8,Edge], [6:0-3-8,Edge]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.49 Vert(LL) 0.19 8-14 >999 240 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.84 Vert(CT) -0.28 8-11 >870 180
TCDL 10.0 Rep Stress Incr YES WB 0.28 Horz(CT) 0.03 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 95 lb FT = 20%

LUMBER 3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.2 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
WEBS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 4) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
5) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied or overhangs non-concurrent with other live loads.
5-2-7 oc purlins.
6) This truss has been designed for a 10.0 psf bottom
BOT CHORD Rigid ceiling directly applied or 8-10-3 oc
chord live load nonconcurrent with any other live loads.
bracing.
7) * This truss has been designed for a live load of 20.0psf
MiTek recommends that Stabilizers and on the bottom chord in all areas where a rectangle
required cross bracing be installed during 3-06-00 tall by 2-00-00 wide will fit between the bottom
truss erection, in accordance with Stabilizer chord and any other members.
Installation guide. 8) Provide mechanical connection (by others) of truss to
bearing plate capable of withstanding 161 lb uplift at joint
REACTIONS (lb/size) 2=752/0-3-0, (min. 0-1-8),
2 and 161 lb uplift at joint 6.
6=752/0-3-0, (min. 0-1-8)
9) This truss is designed in accordance with the 2018
Max Horiz 2=-99 (LC 14)
International Residential Code sections R502.11.1 and
Max Uplift 2=-161 (LC 16), 6=-161 (LC 16) R802.10.2 and referenced standard ANSI/TPI 1.
Max Grav 2=852 (LC 2), 6=853 (LC 2)
LOAD CASE(S) Standard
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-3=-1171/498, 3-15=-886/435,
15-16=-815/446, 4-16=-800/465,
4-17=-800/465, 17-18=-815/446,
5-18=-886/435, 5-6=-1171/498
BOT CHORD 2-19=-392/969, 8-19=-392/969,
8-20=-393/969, 6-20=-393/969
WEBS 4-8=-397/559, 5-8=-346/141, 3-8=-346/141
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) -0-10-8 to
2-1-8, Interior (1) 2-1-8 to 10-0-0, Exterior(2R) 10-0-0 to
13-0-0, Interior (1) 13-0-0 to 20-10-8 zone; cantilever left
and right exposed ; end vertical left and right exposed;
porch left and right exposed;C-C for members and forces
& MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
Job Truss Truss Type Qty Ply

B30812 Gardner T09G Common Supported Gable 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:30 Page: 1
ID:STiLozLapFMmz41vJcNKY9zNNIw-sOtx0LLdHo7?fXEBUpHGiEx42BcQsC6nzhAnllzNI9x

6 8

305 931
T1 ST5 T1
4 ST4 ST4 10
ST3 ST3
3 11
ST2 ST2

ST1 ST1
2 12
HW1 HW1
1 B1 13

Scale = 1:48.3

Plate Offsets (X, Y): [2:0-3-8,Edge], [12:0-3-8,Edge]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.06 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.03 Vert(CT) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.09 Horz(CT) 0.00 12 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 113 lb FT = 20%

LUMBER 4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
TOP CHORD 2x4 SP No.2 Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
BOT CHORD 2x4 SP No.2 DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
OTHERS 2x4 SP No.3 Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
WEDGE Left: 2x4 SP No.3 5) Unbalanced snow loads have been considered for this
Right: 2x4 SP No.3 design.
6) This truss has been designed for greater of min roof live
BRACING
load of 12.0 psf or 1.00 times flat roof load of 15.4 psf on
TOP CHORD Structural wood sheathing directly applied or overhangs non-concurrent with other live loads.
6-0-0 oc purlins.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
8) Gable requires continuous bottom chord bearing.
bracing.
9) Gable studs spaced at 2-0-0 oc.
MiTek recommends that Stabilizers and 10) This truss has been designed for a 10.0 psf bottom
required cross bracing be installed during chord live load nonconcurrent with any other live loads.
truss erection, in accordance with Stabilizer 11) * This truss has been designed for a live load of 20.0psf
Installation guide. on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
REACTIONS All bearings 20-0-0.
chord and any other members.
(lb) - Max Horiz 2=-99 (LC 14), 23=-99 (LC 14)
12) Provide mechanical connection (by others) of truss to
Max Uplift All uplift 100 (lb) or less at joint(s) bearing plate capable of withstanding 100 lb uplift at joint
14, 15, 16, 17, 19, 20, 21, 22 (s) 19, 20, 21, 22, 17, 16, 15, 14.
Max Grav All reactions 250 (lb) or less at joint
13) This truss is designed in accordance with the 2018
(s) 2, 12, 14, 15, 16, 17, 18, 19, 20,
International Residential Code sections R502.11.1 and
21, 22, 23, 27
R802.10.2 and referenced standard ANSI/TPI 1.
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
LOAD CASE(S) Standard
(lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=2ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Corner(3E) -0-10-8 to
2-0-0, Exterior(2N) 2-0-0 to 10-0-0, Corner(3R) 10-0-0 to
13-0-0, Exterior(2N) 13-0-0 to 20-10-8 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
Job Truss Truss Type Qty Ply

B30812 Gardner V01 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:30 Page: 1
ID:P?5_BqVoasGEmIpmtFzGDpzNNjr-sOtx0LLdHo7?fXEBUpHGiEx_aBaDsBsnzhAnllzNI9x

16 17
T2
153 518
T1
19
ST3

ST2 ST2 6
2
14
12 W1
7 ST1

1 B1
7

Scale = 1:46.7

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.41 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.17 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.17 Horiz(TL) 0.00 7 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 89 lb FT = 20%

LUMBER 6) Gable requires continuous bottom chord bearing.


TOP CHORD 2x4 SP No.2 *Except* T2:2x4 SP No.3 7) This truss has been designed for a 10.0 psf bottom
BOT CHORD 2x4 SP No.2 chord live load nonconcurrent with any other live loads.
WEBS 2x4 SP No.3 8) * This truss has been designed for a live load of 20.0psf
OTHERS 2x4 SP No.3 on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
BRACING
chord and any other members, with BCDL = 10.0psf.
TOP CHORD Structural wood sheathing directly applied or
9) Provide mechanical connection (by others) of truss to
6-0-0 oc purlins, except end verticals.
bearing plate capable of withstanding 100 lb uplift at joint
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc (s) 7, 10, 11, 8.
bracing.
10) This truss is designed in accordance with the 2018
MiTek recommends that Stabilizers and International Residential Code sections R502.11.1 and
required cross bracing be installed during R802.10.2 and referenced standard ANSI/TPI 1.
truss erection, in accordance with Stabilizer
LOAD CASE(S) Standard
Installation guide.

REACTIONS All bearings 19-7-3.


(lb) - Max Horiz 1=-88 (LC 14)
Max Uplift All uplift 100 (lb) or less at joint(s)
7, 8, 10, 11
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 7 except 8=433 (LC 28),
9=403 (LC 27), 10=413 (LC 5),
11=393 (LC 27)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
WEBS 3-10=-304/87, 5-8=-311/89
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 11-9-10, Exterior(2R) 11-9-10
to 14-9-10, Interior (1) 14-9-10 to 19-5-14 zone;
cantilever left and right exposed ;C-C for members and
forces & MWFRS for reactions shown; Lumber
DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
4) Unbalanced snow loads have been considered for this
design.
5) All plates are 1.5x4 MT20 unless otherwise indicated.
Job Truss Truss Type Qty Ply

B30812 Gardner V02 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:30 Page: 1
ID:6wimHEc3DwXpzqahTL9ddwzNNjh-sOtx0LLdHo7?fXEBUpHGiExxbBXZsCpnzhAnllzNI9x

4x4 =

14 15
T2
132 T1 ST2 4 16
17

ST1 ST1 1.5x4


12
12 5
7
W1
1 B1
6

1.5x4

Scale = 1:42.1

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.60 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.34 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.11 Horiz(TL) 0.01 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 73 lb FT = 20%

LUMBER 4) Unbalanced snow loads have been considered for this


TOP CHORD 2x4 SP No.3 design.
BOT CHORD 2x4 SP No.2 5) Gable requires continuous bottom chord bearing.
WEBS 2x4 SP No.3 6) This truss has been designed for a 10.0 psf bottom
OTHERS 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf
BRACING
on the bottom chord in all areas where a rectangle
TOP CHORD Structural wood sheathing directly applied or
3-06-00 tall by 2-00-00 wide will fit between the bottom
6-0-0 oc purlins, except end verticals.
chord and any other members, with BCDL = 10.0psf.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
8) Provide mechanical connection (by others) of truss to
bracing.
bearing plate capable of withstanding 100 lb uplift at joint
MiTek recommends that Stabilizers and (s) 6, 9, 7.
required cross bracing be installed during 9) This truss is designed in accordance with the 2018
truss erection, in accordance with Stabilizer International Residential Code sections R502.11.1 and
Installation guide. R802.10.2 and referenced standard ANSI/TPI 1.
REACTIONS All bearings 17-7-3. LOAD CASE(S) Standard
(lb) - Max Horiz 1=-79 (LC 14)
Max Uplift All uplift 100 (lb) or less at joint(s)
6, 7, 9
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 6 except 7=442 (LC 28),
8=361 (LC 27), 9=572 (LC 27)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-12=-314/84
BOT CHORD 1-9=-21/266
WEBS 2-9=-366/95, 4-7=-317/91
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 9-9-10, Exterior(2R) 9-9-10 to
12-9-10, Interior (1) 12-9-10 to 17-5-14 zone; cantilever
left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
Job Truss Truss Type Qty Ply

B30812 Gardner V03 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:30 Page: 1
ID:I1twb?lzeJwFnWvoc9rCZFzNNjW-sOtx0LLdHo7?fXEBUpHGiEx_QBb0sCHnzhAnllzNI9x

4x4 =

13 T2 14
T1 ST2
2 4
12 15

12 ST1 ST1
7
5
W1
1 B1
6

3x6

Scale = 1:37.6

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.42 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.12 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.08 Horiz(TL) 0.00 6 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 57 lb FT = 20%

LUMBER 5) Unbalanced snow loads have been considered for this


TOP CHORD 2x4 SP No.3 design.
BOT CHORD 2x4 SP No.2 6) Gable requires continuous bottom chord bearing.
WEBS 2x4 SP No.3 7) Gable studs spaced at 4-0-0 oc.
OTHERS 2x4 SP No.3 8) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
BRACING
9) * This truss has been designed for a live load of 20.0psf
TOP CHORD Structural wood sheathing directly applied or
on the bottom chord in all areas where a rectangle
6-0-0 oc purlins, except end verticals.
3-06-00 tall by 2-00-00 wide will fit between the bottom
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
chord and any other members.
bracing.
10) Provide mechanical connection (by others) of truss to
MiTek recommends that Stabilizers and bearing plate capable of withstanding 100 lb uplift at joint
required cross bracing be installed during (s) 9, 7.
truss erection, in accordance with Stabilizer 11) This truss is designed in accordance with the 2018
Installation guide. International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
REACTIONS All bearings 14-4-15.
(lb) - Max Horiz 1=-64 (LC 14) LOAD CASE(S) Standard
Max Uplift All uplift 100 (lb) or less at joint(s)
7, 9
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 6 except 7=367 (LC 21),
8=301 (LC 2), 9=406 (LC 20)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
WEBS 2-9=-313/95, 4-7=-295/96
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 7-9-10, Exterior(2R) 7-9-10 to
10-9-10, Interior (1) 10-9-10 to 14-3-10 zone; cantilever
left and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
3) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
4) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
Job Truss Truss Type Qty Ply

B30812 Gardner V04 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:30 Page: 1
ID:?yTihQtEHNAq_3gjCG1YzMzNNjM-sOtx0LLdHo7?fXEBUpHGiExthBRJsBAnzhAnllzNI9x

4x4 =

T1 ST1 T1

12
7
9 10
3
1 B1

Scale = 1:34.9

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.85 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.74 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.15 Horiz(TL) 0.01 4 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 39 lb FT = 20%

LUMBER 5) Gable requires continuous bottom chord bearing.


TOP CHORD 2x4 SP No.3 6) This truss has been designed for a 10.0 psf bottom
BOT CHORD 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
OTHERS 2x4 SP No.3 7) * This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
BRACING
3-06-00 tall by 2-00-00 wide will fit between the bottom
TOP CHORD Structural wood sheathing directly applied or
chord and any other members.
2-2-0 oc purlins.
8) Provide mechanical connection (by others) of truss to
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
bearing plate capable of withstanding 69 lb uplift at joint
bracing.
3.
MiTek recommends that Stabilizers and 9) This truss is designed in accordance with the 2018
required cross bracing be installed during International Residential Code sections R502.11.1 and
truss erection, in accordance with Stabilizer R802.10.2 and referenced standard ANSI/TPI 1.
Installation guide.
LOAD CASE(S) Standard
REACTIONS (lb/size) 1=77/11-6-7, (min. 0-1-8),
3=48/11-6-7, (min. 0-1-8),
4=656/11-6-7, (min. 0-1-8)
Max Horiz 1=-49 (LC 14)
Max Uplift 3=-69 (LC 20)
Max Grav 1=88 (LC 2), 3=157 (LC 21), 4=797
(LC 20)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 2-9=-34/416, 2-10=-34/357, 3-10=-37/294
BOT CHORD 1-4=-270/81, 3-4=-270/72
WEBS 2-4=-606/112
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 5-9-10, Exterior(2R) 5-9-10 to
8-9-10, Interior (1) 8-9-10 to 11-0-13 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
4) Unbalanced snow loads have been considered for this
design.
Job Truss Truss Type Qty Ply

B30812 Gardner V05 Valley 2 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:30 Page: 1
ID:xLbS66uVp?RYDMq6Jh302nzNNjK-sOtx0LLdHo7?fXEBUpHGiEx?LBX5sCQnzhAnllzNI9x

4x4 =

12 T1 ST1 T1
7

B1
1 3

Scale = 1:33.2

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.36 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.37 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.07 Horiz(TL) 0.00 3 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 25 lb FT = 20%

LUMBER 6) This truss has been designed for a 10.0 psf bottom
TOP CHORD 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
BOT CHORD 2x4 SP No.3 7) * This truss has been designed for a live load of 20.0psf
OTHERS 2x4 SP No.3 on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
BRACING
chord and any other members.
TOP CHORD Structural wood sheathing directly applied or
8) Provide mechanical connection (by others) of truss to
7-6-7 oc purlins.
bearing plate capable of withstanding 3 lb uplift at joint 1
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
and 3 lb uplift at joint 3.
bracing.
9) This truss is designed in accordance with the 2018
MiTek recommends that Stabilizers and International Residential Code sections R502.11.1 and
required cross bracing be installed during R802.10.2 and referenced standard ANSI/TPI 1.
truss erection, in accordance with Stabilizer
LOAD CASE(S) Standard
Installation guide.

REACTIONS (lb/size) 1=41/7-6-7, (min. 0-1-8),


3=41/7-6-7, (min. 0-1-8),
4=451/7-6-7, (min. 0-1-8)
Max Horiz 1=-32 (LC 14)
Max Uplift 1=-3 (LC 21), 3=-3 (LC 20)
Max Grav 1=89 (LC 20), 3=89 (LC 21), 4=510
(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
WEBS 2-4=-357/108
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 3-9-10, Exterior(2R) 3-9-10 to
6-6-5, Interior (1) 6-6-5 to 7-6-13 zone; cantilever left and
right exposed ; end vertical left and right exposed;C-C
for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
4) Unbalanced snow loads have been considered for this
design.
5) Gable requires continuous bottom chord bearing.
Job Truss Truss Type Qty Ply

B30812 Gardner V06 Valley 2 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:31 Page: 1
ID:MwHbk7xN5wp74qZh_pcjgPzNNjH-LaRJEhMF26FsGhpN1XoVFSUDEbwmbgmwCLwKHCzNI9w

3x4 =

12
7 2
T1 T1

B1
1 3

Scale = 1:31.4

Plate Offsets (X, Y): [2:0-2-0,Edge]

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.16 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.15 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) 0.00 3 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 10 lb FT = 20%

LUMBER 8) This truss is designed in accordance with the 2018


TOP CHORD 2x4 SP No.3 International Residential Code sections R502.11.1 and
BOT CHORD 2x4 SP No.3 R802.10.2 and referenced standard ANSI/TPI 1.
BRACING LOAD CASE(S) Standard
TOP CHORD Structural wood sheathing directly applied or
3-6-7 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
bracing.
MiTek recommends that Stabilizers and
required cross bracing be installed during
truss erection, in accordance with Stabilizer
Installation guide.

REACTIONS (lb/size) 1=125/3-6-7, (min. 0-1-8),


3=125/3-6-7, (min. 0-1-8)
Max Horiz 1=-14 (LC 14)
Max Grav 1=141 (LC 2), 3=141 (LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) zone;
cantilever left and right exposed ; end vertical left and
right exposed;C-C for members and forces & MWFRS
for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
4) Unbalanced snow loads have been considered for this
design.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf
on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
chord and any other members.
Job Truss Truss Type Qty Ply

B30812 Gardner V07 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:31 Page: 1
ID:it4Unr_WwSRQBbRenMCuNTzNNjC-LaRJEhMF26FsGhpN1XoVFSU5abubbdswCLwKHCzNI9w

4x4 =
3

15 16

142 T1 ST2 T1 417

13 ST1 ST1 18
12
7

1 B1 5

Scale = 1:43.9

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.65 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.29 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.25 Horiz(TL) 0.00 5 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 77 lb FT = 20%

LUMBER 4) Unbalanced snow loads have been considered for this


TOP CHORD 2x4 SP No.3 design.
BOT CHORD 2x4 SP No.2 5) Gable requires continuous bottom chord bearing.
OTHERS 2x4 SP No.3 6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
BRACING
7) * This truss has been designed for a live load of 20.0psf
TOP CHORD Structural wood sheathing directly applied or
on the bottom chord in all areas where a rectangle
10-0-0 oc purlins.
3-06-00 tall by 2-00-00 wide will fit between the bottom
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
chord and any other members, with BCDL = 10.0psf.
bracing.
8) Provide mechanical connection (by others) of truss to
MiTek recommends that Stabilizers and bearing plate capable of withstanding 100 lb uplift at joint
required cross bracing be installed during (s) 8, 6.
truss erection, in accordance with Stabilizer 9) This truss is designed in accordance with the 2018
Installation guide. International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
REACTIONS All bearings 19-6-7.
(lb) - Max Horiz 1=87 (LC 15) LOAD CASE(S) Standard
Max Uplift All uplift 100 (lb) or less at joint(s)
6, 8
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 5 except 6=560 (LC 28),
7=569 (LC 27), 8=561 (LC 27)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-13=-116/302, 13-14=-14/370, 2-14=-4/378,
3-15=0/315, 3-16=0/304, 4-17=-1/350,
17-18=-14/343, 5-18=-30/275
WEBS 3-7=-428/0, 2-8=-362/94, 4-6=-362/94
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 9-9-10, Exterior(2R) 9-9-10 to
12-9-10, Interior (1) 12-9-10 to 19-6-13 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
Job Truss Truss Type Qty Ply

B30812 Gardner V08 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:31 Page: 1
ID:7SmcQs1ODNp_22ADSUmb?5zNNj9-LaRJEhMF26FsGhpN1XoVFSU9?bxPbfCwCLwKHCzNI9w

4x4 =

15T1 T1
16
ST2
2 4
14 17
13 18
12 ST1 ST1
7

1 B1 5

Scale = 1:39.4

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.43 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.11 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.10 Horiz(TL) 0.00 5 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 59 lb FT = 20%

LUMBER 6) This truss has been designed for a 10.0 psf bottom
TOP CHORD 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
BOT CHORD 2x4 SP No.2 7) * This truss has been designed for a live load of 20.0psf
OTHERS 2x4 SP No.3 on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
BRACING
chord and any other members.
TOP CHORD Structural wood sheathing directly applied or
8) Provide mechanical connection (by others) of truss to
6-0-0 oc purlins.
bearing plate capable of withstanding 100 lb uplift at joint
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
(s) 8, 6.
bracing.
9) This truss is designed in accordance with the 2018
MiTek recommends that Stabilizers and International Residential Code sections R502.11.1 and
required cross bracing be installed during R802.10.2 and referenced standard ANSI/TPI 1.
truss erection, in accordance with Stabilizer
LOAD CASE(S) Standard
Installation guide.

REACTIONS All bearings 15-6-7.


(lb) - Max Horiz 1=-68 (LC 14)
Max Uplift All uplift 100 (lb) or less at joint(s)
6, 8
Max Grav All reactions 250 (lb) or less at joint
(s) 1, 5 except 6=405 (LC 21),
7=341 (LC 2), 8=405 (LC 20)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
WEBS 3-7=-271/0, 2-8=-312/88, 4-6=-312/88
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 7-9-10, Exterior(2R) 7-9-10 to
10-9-10, Interior (1) 10-9-10 to 15-6-13 zone; cantilever
left and right exposed ; end vertical left and right
exposed;C-C for members and forces & MWFRS for
reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
4) Unbalanced snow loads have been considered for this
design.
5) Gable requires continuous bottom chord bearing.
Job Truss Truss Type Qty Ply

B30812 Gardner V09 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:31 Page: 1
ID:X1Rl2u3HWIBZvWvo8dJIckzNNj6-LaRJEhMF26FsGhpN1XoVFSU2HbnsbeywCLwKHCzNI9w

4x4 =

T1 ST1 T1

12
7
9 10

1 B1 3

Scale = 1:34.9

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.86 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.72 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.18 Horiz(TL) 0.01 4 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MS
BCDL 10.0 Weight: 39 lb FT = 20%

LUMBER 4) Unbalanced snow loads have been considered for this


TOP CHORD 2x4 SP No.3 design.
BOT CHORD 2x4 SP No.3 5) Gable requires continuous bottom chord bearing.
OTHERS 2x4 SP No.3 6) This truss has been designed for a 10.0 psf bottom
chord live load nonconcurrent with any other live loads.
BRACING
7) * This truss has been designed for a live load of 20.0psf
TOP CHORD Structural wood sheathing directly applied or
on the bottom chord in all areas where a rectangle
2-2-0 oc purlins.
3-06-00 tall by 2-00-00 wide will fit between the bottom
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc
chord and any other members.
bracing.
8) Provide mechanical connection (by others) of truss to
MiTek recommends that Stabilizers and bearing plate capable of withstanding 54 lb uplift at joint
required cross bracing be installed during 1, 54 lb uplift at joint 3 and 7 lb uplift at joint 4.
truss erection, in accordance with Stabilizer 9) This truss is designed in accordance with the 2018
Installation guide. International Residential Code sections R502.11.1 and
R802.10.2 and referenced standard ANSI/TPI 1.
REACTIONS (lb/size) 1=13/11-6-7, (min. 0-1-8),
3=13/11-6-7, (min. 0-1-8), LOAD CASE(S) Standard
4=791/11-6-7, (min. 0-1-8)
Max Horiz 1=50 (LC 15)
Max Uplift 1=-54 (LC 21), 3=-54 (LC 20), 4=-7
(LC 16)
Max Grav 1=68 (LC 33), 3=68 (LC 34), 4=894
(LC 2)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-9=-68/323, 2-9=-65/465, 2-10=-65/465,
3-10=-68/323
BOT CHORD 1-4=-334/103, 3-4=-334/103
WEBS 2-4=-701/141
NOTES
1) Unbalanced roof live loads have been considered for this
design.
2) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-7 to
3-0-7, Interior (1) 3-0-7 to 5-9-10, Exterior(2R) 5-9-10 to
8-9-10, Interior (1) 8-9-10 to 11-6-13 zone; cantilever left
and right exposed ; end vertical left and right exposed;C-
C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
Job Truss Truss Type Qty Ply

B30812 Gardner V10 Valley 1 1 Job Reference (optional)


K-I Truss, Shelbyville, Ky 40065 Run: 8.53 S Apr 27 2022 Print: 8.530 S Apr 27 2022 MiTek Industries, Inc. Tue Apr 25 15:55:31 Page: 1
ID:?E?7FE4vHcJQXgU_hKqX9xzNNj5-LaRJEhMF26FsGhpN1XoVFSU7Sbp7bgmwCLwKHCzNI9w

1.5x4

2
12
4 7T1 W1

6 B1
1 3

1.5x4

Scale = 1:23.9

Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP
TCLL (roof) 20.0 Plate Grip DOL 1.15 TC 0.53 Vert(LL) n/a - n/a 999 MT20 244/190
Snow (Pf/Pg) 15.4/20.0 Lumber DOL 1.15 BC 0.64 Vert(TL) n/a - n/a 999
TCDL 10.0 Rep Stress Incr YES WB 0.00 Horiz(TL) 0.01 3 n/a n/a
BCLL 0.0 * Code IRC2018/TPI2014 Matrix-MP
BCDL 10.0 Weight: 15 lb FT = 20%

LUMBER 7) This truss has been designed for a 10.0 psf bottom
TOP CHORD 2x4 SP No.3 chord live load nonconcurrent with any other live loads.
BOT CHORD 2x4 SP No.3 8) * This truss has been designed for a live load of 20.0psf
WEBS 2x4 SP No.3 on the bottom chord in all areas where a rectangle
3-06-00 tall by 2-00-00 wide will fit between the bottom
BRACING
chord and any other members.
TOP CHORD Structural wood sheathing directly applied or
9) Provide mechanical connection (by others) of truss to
4-10-14 oc purlins, except end verticals.
bearing plate capable of withstanding 2 lb uplift at joint 3.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc
10) This truss is designed in accordance with the 2018
bracing.
International Residential Code sections R502.11.1 and
MiTek recommends that Stabilizers and R802.10.2 and referenced standard ANSI/TPI 1.
required cross bracing be installed during LOAD CASE(S) Standard
truss erection, in accordance with Stabilizer
Installation guide.

REACTIONS (lb/size) 1=166/4-10-2, (min. 0-1-8),


3=166/4-10-2, (min. 0-1-8)
Max Horiz 1=32 (LC 16)
Max Uplift 3=-2 (LC 16)
Max Grav 1=220 (LC 20), 3=220 (LC 20)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250
(lb) or less except when shown.
TOP CHORD 1-6=-479/132, 1-6=-461/135
BOT CHORD 1-3=-199/447
NOTES
1) Wind: ASCE 7-16; Vult=115mph (3-second gust)
Vasd=91mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft;
B=45ft; L=24ft; eave=4ft; Cat. II; Exp B; Enclosed;
MWFRS (directional) and C-C Exterior(2E) 0-0-12 to
3-0-12, Interior (1) 3-0-12 to 4-9-2 zone; cantilever left
and right exposed ;C-C for members and forces &
MWFRS for reactions shown; Lumber DOL=1.60 plate
grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss
only. For studs exposed to wind (normal to the face),
see Standard Industry Gable End Details as applicable,
or consult qualified building designer as per ANSI/TPI 1.
3) TCLL: ASCE 7-16; Pr=20.0 psf (roof LL: Lum DOL=1.15
Plate DOL=1.15); Pg=20.0 psf; Pf=15.4 psf (Lum
DOL=1.15 Plate DOL=1.15); Is=1.0; Rough Cat B;
Partially Exp.; Ce=1.0; Cs=1.00; Ct=1.10
4) Unbalanced snow loads have been considered for this
design.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 4-0-0 oc.

You might also like