NEA-QMS-SP-XX Transformer
NEA-QMS-SP-XX Transformer
Prepared by: Endorsed for approval by: Reviewed by: Approved by:
1.0 OBJECTIVE
This manual aims to guide Electric Cooperatives (ECs) in filling out and submitting Master Data templates through Helpdesk Support
whenever there are changes in master data such as updates, modifications, etc. This must be observed in order to successfully
provide data for any modifications in Transformer Master Data.
2.0 SCOPE
This manual establishes the guidelines of Master Data standardization procedures for the submission of Transformer Master Data
through Helpdesk Support performed by Electric Cooperatives (ECs).
Master Data (MD) - Data representing standard business information which are common and shared across
users and managed centrally at NEA. These can be modified as requested by the Users for
the addition of new values, updating or revisions and deactivation.
Master Data Template - Template used for updating the MD in the NEA Web Portal.
Helpdesk Support - Responsible for receiving and assessing the information on reported incident and request
Helpdesk tickets.
Required? (Y/N) - Indicates if a field is required to be filled up or not.
Source - Indicates if field information is a data entry or calculated automatically in the data entry
template.
Transformer Master Data - Template used for updating the MD of all transformers of the EC in the NEA Web Portal.
Template
Validation Rules - Standard values that should be entered in the data entry field or criteria that should be
followed.
Electric Cooperatives - Responsible for accomplishing and submitting Master Data (MD) Templates and DETs.
(ECs) Also accountable for the correctness and accuracy of the submitted data as reflected in
the MD Templates and DETs.
5.0 MANUAL
The definition of each data entry field that corresponds to the columns found in the Master Data template.
Existing Report
Data Entry Required? Existing
Description Source Formula Validation Rules Existing Report Field
Field (Y/N) Report Table
Equivalent
EC Short The acronym of the Y Data Entry N/A Value should be New New New
Name Electric Cooperative (EC). selected from the list of
dropdown values.
List of dropdown values
will refer to Master List –
EC Profile. (E.g. BENECO,
CENPELCO, INEC, etc.).
Substation The name of the substation Y Data Entry N/A None. New New New
Name of the transformer being
accounted.
Transformer The unit ID of the Y Data Entry N/A None. New New New
Unit ID transformer.
Transformer The date when the Y Data Entry N/A Date should not be New New New
Manufacturin transformer was earlier than the date
g Date manufactured. today.
Date format is
MM/DD/YYYY.
Energization The date when the Y Data Entry N/A Date should not be New New New
Date transformer was earlier than the date
energized.1 today.
Date format is
MM/DD/YYYY.
Brand The brand of the Y Data Entry N/A None. New New New
transformer.
Serial No. The serial number Y Data Entry N/A None. New New New
assigned to the
transformer.
Rated The ONAN (C57.12.00) Y Data Entry N/A Value should be whole New New New
1
If there are multiple energization dates, input the latest energization date
Existing Report
Data Entry Required? Existing
Description Source Formula Validation Rules Existing Report Field
Field (Y/N) Report Table
Equivalent
Capacity rating of the transformer. number.
(MVA)
The owner of the Y Data Entry N/A None. New New New
Transformer (e.g. EC,
Ownership NGCP).
Status The current state of the Y Data Entry N/A Value should be New New New
transformer. selected from the list of
dropdown values.
List of values are:
De-Energized
Defective
Idle
Maintenance
Non-Operational
Operational
Spare
Stand-by
Stop Operation
No. of Feeder Feeder count per Y Data Entry N/A Value should be whole New New New
per Power transformer energized and number.
Transformer unenergized.
Remarks Free text field where N Data Entry N/A None. New New New
comments related to the
entered values in the
template can be indicated.
Notes:
- Submission is still required even if the transformer is Idle/ Stock /Standby.
- All existing power transformers (3-Phase and 1 Phase - 500 kVA and above) within the EC franchise area including consumer
owned are accounted in this DET.
6.0 PROCEDURE
7.0 REFERENCE
8.0 ATTACHMENTS
9.0 RECORDS