0% found this document useful (0 votes)
309 views24 pages

VEGAMET 841 Controller Display Instrument Product Information Compressed

This document provides product information on various VEGAMET controllers for continuously measuring level sensors, including the VEGAMET 141, 142, 341, 342, 841, and 862. It describes their functional principles, applications, safety features, and adjustment methods. The type overview section lists the key specifications and features of the VEGAMET 141 and 142 models, such as their mounting types, measurement loops, inputs/outputs, and displays.

Uploaded by

vichit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
309 views24 pages

VEGAMET 841 Controller Display Instrument Product Information Compressed

This document provides product information on various VEGAMET controllers for continuously measuring level sensors, including the VEGAMET 141, 142, 341, 342, 841, and 862. It describes their functional principles, applications, safety features, and adjustment methods. The type overview section lists the key specifications and features of the VEGAMET 141 and 142 models, such as their mounting types, measurement loops, inputs/outputs, and displays.

Uploaded by

vichit
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Product information

Controllers and communication

Controllers in field housing for continuously measuring level


sensors
VEGAMET 141, 142
VEGAMET 341, 342
VEGAMET 841, 842
VEGAMET 861, 862

Document ID: 62826


Contents

Contents
1 Product description................................................................................................................................................................................................ 3

2 Type overview.......................................................................................................................................................................................................... 4

3 Instrument selection............................................................................................................................................................................................... 7

4 Selection criteria..................................................................................................................................................................................................... 8

5 Mounting................................................................................................................................................................................................................ 13

6 Electrical connection............................................................................................................................................................................................ 15

7 Adjustment............................................................................................................................................................................................................ 18

8 Dimensions............................................................................................................................................................................................................ 19

Take note of safety instructions for Ex applications


Please note the Ex specific safety information which you can find on our homepage www.vega.com/downloads under " Approvals" and which
62826-EN-210818

comes with every instrument. In hazardous areas you should take note of the corresponding regulations, conformity and type approval certifi-
cates of the sensors and power supply units. The sensors must only be operated on intrinsically safe circuits. The permissible electrical values
are stated in the certificate.

2 Controllers and communication


Product description

1 Product description
Functional principle
In continuous measurement, for example, the level in a vessel is detected
by a sensor and then transferred to a controller for further processing.
By means of an adjustment in the controller, the measured value can 2
be adapted to the individual circumstances. The requested measure- 1
ment parameter is indicated in the display via a scaling/linearisation. The
measured value can be transmitted additionally to a connected control
system or visualisation via the current output.
3
Several operating relays are additionally integrated in each VEGAMET for
level detection. These can be used to control pumps or other actuators.

Application
The controllers can be used in connection with the appropriate sensors
for a large number of measuring tasks. Preset applications and functions Fig. 1: Wireless connection to smartphone/table/notebook
are already integrated for convenient set-up which can be selected and 1 VEGAMET
adapted very easily by means of an application wizard. 2 Smartphone/Tablet
The following applications and functions are available, for example, 3 PC/Notebook
depending on the instrument type:
• Universal
• Level storage tank
• Calculation difference
• Calculation total
• Calculation of average value
• Wells
• Pumping station
• Sewage screw lifting station
• Density
• Overflow basin
• Screen control
• Flow measurement flume/weir
• Pressurized vessel
• Measured value memory/data logger
All instruments also serve as a (Ex) power supply unit for the connected
sensors. Power is supplied via the same two-wire cable. As an option
in the non-Ex versions, an input without sensor power supply (passive
input) is available, enabling the connection of transmitters with their own
voltage supply (sensors in four-wire version). Depending on the instru-
ment type, one or two independent sensors can be connected and their
measured values processed.

Safety
The integrated function monitoring detects faults in the controller as well
as in the connected sensors. If such a fault is detected, the integrated
fail safe relay de-energises (safe status) and a fault signal is output
via the LEDs on the front panel. In addition, the current output of each
VEGAMET jumps to an adjustable fault current.
The instrument has the following approvals:
• Ex approval as auxiliary, intrinsically safe instrument
• Ship approval for the VEGAMET series 100/300
• Certificate as WHG-conform limit signal transmitter

Adjustment
All devices can be operated on site via the integrated display and adjust-
ment unit. Wireless operation via Bluetooth using the following adjust-
ment tools is also possible:
• Smartphone/tablet (iOS or Android operating system)
• PC/notebook with Bluetooth LE or Bluetooth USB adapter (Windows
operating system)
62826-EN-210818

Controllers and communication 3


Type overview

2 Type overview
VEGAMET 141 VEGAMET 142

Mounting Carrier rail mounting Carrier rail mounting


Application • Level/gauge measurement • Level/gauge measurement
• Wells • Wells
• Pumping station • Pumping station
• Sewage screw lifting station • Sewage screw lifting station
• Process pressure measurement • Flow measurement
• Flow measurement • Density
• Overflow basin
• Screen control
• Pressurized vessel
• Calculation difference/sum/average
Measurement loops 1 Measurement loop 2 measuring loops, 1 arithmetic measur-
ing loop
Sensor inputs 1 x 4 … 20 mA 2 x 4 … 20 mA
Digital inputs - -
Outputs • 3 x operating relay, one can be config- • 3 x operating relay, one can be config-
ured as fail safe relay ured as fail safe relay
• 1 x current output • 2 x current outputs
Display on the instrument • Graphic-capable LC display, with lighting • Graphic-capable LC display, with lighting
• LEDs for operation, relays, fault signal • LEDs for operation, relays, fault signal
• Configurable status indication via dis- • Configurable status indication via dis-
play background lighting play background lighting
Measured value memory - -
Interfaces Bluetooth LE Bluetooth LE
Ambient temperature -40 … +60 °C (-40 … +140 °F) -40 … +60 °C (-40 … +140 °F)

62826-EN-210818

4 Controllers and communication


Type overview

VEGAMET 341 VEGAMET 342

Mounting Panel mounting Panel mounting


Application • Level/gauge measurement • Level/gauge measurement
• Wells • Wells
• Pumping station • Pumping station
• Sewage screw lifting station • Sewage screw lifting station
• Process pressure measurement • Flow measurement
• Flow measurement • Density
• Overflow basin
• Screen control
• Pressurized vessel
• Calculation difference/sum/average
Measurement loops 1 Measurement loop 2 measuring loops, 1 arithmetic measur-
ing loop
Sensor inputs 1 x 4 … 20 mA 2 x 4 … 20 mA
Digital inputs - -
Outputs • 3 x operating relay, one can be config- • 3 x operating relay, one can be config-
ured as fail safe relay ured as fail safe relay
• 1 x current output • 2 x current outputs
Display on the instrument • Graphic-capable LC display, with lighting • Graphic-capable LC display, with lighting
• LEDs for operation, relays, fault signal • LEDs for operation, relays, fault signal
• Configurable status indication via dis- • Configurable status indication via dis-
play background lighting play background lighting
Measured value memory - -
Interfaces Bluetooth LE Bluetooth LE
Ambient temperature -40 … +60 °C (-40 … +140 °F) -40 … +60 °C (-40 … +140 °F)

VEGAMET 841 VEGAMET 842

Mounting Wall/pipe assembly Wall/pipe assembly


Application • Level/gauge measurement • Level/gauge measurement
• Wells • Wells
• Pumping station • Pumping station
• Sewage screw lifting station • Sewage screw lifting station
• Process pressure measurement • Flow measurement
• Flow measurement • Density
• Overflow basin
• Screen control
• Pressurized vessel
• Calculation difference/sum/average
Measurement loops 1 Measurement loop 2 measuring loops, 1 arithmetic measur-
ing loop
Sensor inputs 1 x 4 … 20 mA 2 x 4 … 20 mA
Digital inputs - -
Outputs • 3 x operating relay, one can be config- • 3 x operating relay, one can be config-
ured as fail safe relay ured as fail safe relay
• 1 x current output • 2 x current outputs
Display on the instrument • Graphic-capable LC display, with lighting • Graphic-capable LC display, with lighting
• LEDs for operation, relays, fault signal • LEDs for operation, relays, fault signal
• Configurable status indication via dis- • Configurable status indication via dis-
play background lighting play background lighting
Measured value memory - -
Interfaces Bluetooth LE Bluetooth LE
Ambient temperature -40 … +60 °C (-40 … +140 °F) -40 … +60 °C (-40 … +140 °F)
62826-EN-210818

Controllers and communication 5


Type overview

VEGAMET 861 VEGAMET 862

Mounting Wall/pipe assembly Wall/pipe assembly


Application • Level/gauge measurement • Level/gauge measurement
• Wells • Wells
• Pumping station • Pumping station
• Sewage screw lifting station • Sewage screw lifting station
• Process pressure measurement • Flow measurement
• Flow measurement • Density
• Overflow basin
• Screen control
• Pressurized vessel
• Calculation difference/sum/average
Measurement loops 1 Measurement loop 2 measuring points, 1 differential measur-
ing point
Sensor inputs 1 x 4 … 20 mA/HART 2 x 4 … 20 mA/HART
Digital inputs 2 Digital inputs 4 Digital inputs
Outputs • 4 x operating relay, one can be config- • 6 x operating relay, one can be config-
ured as fail safe relay ured as fail safe relay
• 1 x current output • 3 x current output
Display on the instrument • Graphic-capable LC display, with lighting • Graphic-capable LC display, with lighting
• LEDs for operation, relays, fault signal • LEDs for operation, relays, fault signal
• Configurable status indication via dis- • Configurable status indication via dis-
play background lighting play background lighting
Measured value memory Internal memory and SD card Internal memory and SD card
Interfaces Bluetooth LE Bluetooth LE
Ambient temperature -40 … +60 °C (-40 … +140 °F) -40 … +60 °C (-40 … +140 °F)

62826-EN-210818

6 Controllers and communication


Instrument selection

3 Instrument selection
All controllers of the 100, 300 and 800 instrument series power the
connected sensors, process the measured values and display these
on the integrated display and adjustment unit. Up to two 4 … 20 mA or
4 … 20 mA/HART sensors can be connected depending on the instru-
ment version.
The instruments enable simple implementation of pump controls, flow
measurements on open channels and weirs, totalizers, difference, sum
and average value calculations. Limit values can be reliably monitored
and relays can be switched, e.g. for an overfill protection according to
WHG.
All instruments have a graphic display with background lighting. This
serves at the same time as a status display visible from a great distance.
The background lighting changes in he delivery status according to
NAMUR NE 107 (e. g. red for fault, orange for function check). Alterna-
tively, the status display can also be configured based on the relay or the
measured value. When the measured value is used, for example, up to
five operating states can be signalled depending on the level.

The three instrument series 100, 300 and 800 differ mainly in the protec-
tion rating and the assembly possibilities and thus also in the housing.

VEGAMET series 100


The compact series is ideal for mounting on rails, e.g. in switch cabinets.
A graphic display for on-site data visualisation and checking as well as a
turn/oush button for simple on-site adjustment are integrated.

VEGAMET series 300


The built-in housing is ideal for mounting in the panel or switch cabinet
door. A large graphic display for on-site data visualisation and checking
as well as a turn/push button for simple on-site adjustment are integrated.

VEGAMET series 800


The housings are designed for wall/pipe assembly and harsh field condi-
tions, e.g. outdoors. A large graphic display for on-site data visualisation
and checking as well as push buttons for easy on-site adjustment are
integrated.
The VEGAMET 861/862 has 4 … 20 mA/HART sensor inputs. Digital
inputs and a measured value memory/data logger are additionally avail-
able.
62826-EN-210818

Controllers and communication 7


Selection criteria

4 Selection criteria
The following charts provide an overview of the standard applications and functions of the controllers. They also give information about whether the respective function
can be activated and adjusted via the integrated indicating and adjustment unit (OP) or via DTM/app. 1)

VEGAMET 141, 142


Applications (adjustable with DTM/app) VEGAMET Adjustment
141 142 OP DTM/App
Universal • • • •
Level - storage tank • • •
Calculation Difference • •
Total • •
Average value • •
Wells • • •
Pumping station • • •
Sewage screw lifting station • • •
Screen control • •
Flow measurement - flume/weir • • •
Pressurized vessel • •

Additional application examples VEGAMET Adjustment


141 142 OP DTM/App
Level measurement • • •
Gauge measurement • • •
Process pressure measurement • • •
Overflow basin • •
Density • •

Functions VEGAMET Adjustment


141 142 OP DTM/App
Application wizard • • •
Indication measured values • • • •
Automatic display change • • • •
Configurable status indication via background lighting of the display • • •
Display multilingual • • • •
Sensor input - 4 … 20 mA • • • •
Damping • • • •
Linearisation Predefined curves • • • •
Dimensions - ISO standard • • •
Flow formula • • •
Manufacturer definition • • •
Calculation wizard • • •
Locating chart • • •
Measure • • •
Import • • •
Adjustment of the measuring point • • • •
Scaling • • • •
Totalizer 1/2 • • • •
Totalizer 3/4/5/6 • •
62826-EN-210818

1)
OP: Operating Panel (integrated display and adjustment unit)

8 Controllers and communication


Selection criteria

Functions VEGAMET Adjustment


141 142 OP DTM/App
Relay mode Overfill protection • • • •
Dry run protection • • • •
Switching window ON • • •
Switching window OFF • • •
Flow volume pulse • • •
Sampling pulse • • •
Tendency increasing • • •
Tendency decreasing • • •
Pump control 1 (same running time) • • •
Pump control 2 (same running time) • • •
Pump control 3 (fixed order) • • •
Pump control 4 (fixed order) • • •
Mode Pump control - sequenced operation • • •
Pump control - alternating pump operation • • •
Dry weather pump • • •
Forced pump changeover • • •
Relay switch on and off delay • • •
Bandwidth for switching points • • •
Fail safe relay • • • •
Current output 0/4 … 20 mA, 20 … 4 mA • • • •
Flow volume pulse • • •
Sampling pulse • • •
Diagnostics Status • • • •
Measured values • • • •
Simulation Sensor value, %, lin% value, scaled values • • • •
Current output • • •
Relay output • • •
Protection of the parameterization • • • •
Bluetooth access code • • • •
Activate/deactivate Bluetooth communication • • •

VEGAMET 341, 342


Applications (adjustable with DTM/app) VEGAMET Adjustment
341 342 OP DTM/App
Universal • • • •
Level - storage tank • • •
Calculation Difference • •
Total • •
Average value • •
Wells • • •
Pumping station • • •
Sewage screw lifting station • • •
Screen control • •
Flow measurement - flume/weir • • •
Pressurized vessel • •

Additional application examples VEGAMET Adjustment


341 342 OP DTM/App
Level measurement • • •
Gauge measurement • • •
62826-EN-210818

Process pressure measurement • • •


Overflow basin • •

Controllers and communication 9


Selection criteria

Additional application examples VEGAMET Adjustment


341 342 OP DTM/App
Density • •

Functions VEGAMET Adjustment


341 342 OP DTM/App
Application wizard • • •
Indication measured values • • • •
Automatic display change • • • •
Configurable status indication via background lighting of the display • • •
Display multilingual • • • •
Sensor input - 4 … 20 mA • • • •
Damping • • • •
Linearisation Predefined curves • • • •
Dimensions - ISO standard • • •
Flow formula • • •
Manufacturer definition • • •
Calculation wizard • • •
Locating chart • • •
Measure • • •
Linearization curves - Import • • •
Adjustment of the measuring point • • • •
Scaling • • • •
Totalizer 1/2 • • •
Totalizer 3/4/5/6 • •
Relay mode Overfill protection • • • •
Dry run protection • • • •
Switching window ON • • •
Switching window OFF • • •
Flow volume pulse • • •
Sampling pulse • • •
Tendency increasing • • •
Tendency decreasing • • •
Pump control 1 (same running time) • • •
Pump control 2 (same running time) • • •
Pump control 3 (fixed order) • • •
Pump control 4 (fixed order) • • •
Mode Pump control - sequenced operation • • •
Pump control - alternating pump operation • • •
Dry weather pump • • •
Forced pump changeover • • •
Relay switch on and off delay • • •
Bandwidth for switching points • • •
Fail safe relay • • • •
Current output 0/4 … 20 mA, 20 … 4 mA • • • •
Flow volume pulse • • •
Sampling pulse • • •
Diagnostics Status • • • •
Measured values • • • •
Simulation Sensor value, %, lin% value, scaled values • • • •
Current output • • •
Relay output • • •
62826-EN-210818

Protection of the parameterization • • • •


Bluetooth access code • • • •

10 Controllers and communication


Selection criteria

Functions VEGAMET Adjustment


341 342 OP DTM/App
Activate/deactivate Bluetooth communication • • •

VEGAMET 841, 842, 861, 862


Applications (adjustable with DTM/app) VEGAMET Adjustment
841 842 861 862 OP DTM/App
Universal • • • • • •
Level - storage tank • • • • •
Calculation - difference • • •
Flow measurement - flume/weir • • • • •
Pumping station • • • • •
Screen control • • •
Sewage screw lifting station • • • • •

Additional application examples VEGAMET Adjustment


841 842 861 862 OP DTM/App
Level measurement • • • • •
Gauge measurement • • • • •
Process pressure measurement • • • • •

Functions VEGAMET Adjustment


841 842 861 862 OP DTM/App
Application wizard • • • • •
Indication measured values • • • • • •
Automatic display change • • • • • •
Configurable status indication via background lighting of the display • • • • •
Display multilingual • • • • • •
Sensor input 4 … 20 mA • • • • • •
HART • • • •
Damping • • • • • •
Linearisation Predefined curves • • • • • •
Dimensions - ISO standard • • • • •
Flow formula • • • • •
Manufacturer definition • • • • •
Calculation wizard • • • • •
Locating chart • • • • •
Measure • • • • •
Import linearization curves • • • • •
Adjustment of the measuring point • • • • • •
Scaling • • • • • •
Totalizer 1/2 • • • • •
Totalizer 3/4 • • •
62826-EN-210818

Controllers and communication 11


Selection criteria

Functions VEGAMET Adjustment


841 842 861 862 OP DTM/App
Relay mode Overfill protection • • • • • •
Dry run protection • • • • • •
Switching window ON • • • • •
Switching window OFF • • • • •
Flow volume pulse • • • • •
Sampling pulse • • • • •
Tendency increasing • • • • •
Tendency decreasing • • • • •
Pump control 1 (same running time) • • • • •
Pump control 2 (same running time) • • • • •
Pump control 3 (fixed order) • • • • •
Pump control 4 (fixed order) • • • • •
Mode Pump control - sequenced operation • • • • •
Pump control - alternating pump operation • • • • •
Dry weather pump • • • • •
Pump monitoring • • •
Forced pump changeover • • • • •
Relay - Switch on and off delay • • • • •
Bandwidth for switching points • • • • •
Fail safe relay • • • • • •
Current output 0/4 … 20 mA, 20 … 4 mA • • • • • •
Flow volume pulse • • • • •
Sampling pulse • • • • •
Diagnostics Status • • • • • •
Measured values • • • • • •
Simulation Sensor value, %, lin% value, scaled values • • • • • •
Current output • • • • •
Relay output • • • • •
Digital input • • •
Date/Time • • • •
Internal device memory/SD card • • •
Protection of the parameterization • • • • • •
Bluetooth access code • • • • • •

62826-EN-210818

12 Controllers and communication


Mounting

5 Mounting
5.1 VEGAMET 141, 142 82 mm
(3.23")
Mounting options
VEGAMET is designed for carrier rail mounting (top hat rail 35 x 7.5
according to DIN EN 50022/60715). Due to its protection rating of IP20,
the instrument is suitable for mounting in switching cabinets. It must be
mounted vertically.

82 mm
(3.23")
A VEGAMET in Ex version is an auxiliary, intrinsically safe instru-
ment and may not be installed in explosion-endangered areas.

5.2 VEGAMET 341, 342


Mounting options
ø7 mm
The device is designed for recessed installation in a switching cabi- (0.28")
net, housing front panel or switch cabinet door. The required cut-out is ø13 mm
92 x 92 mm (3.63 x 3.63 in) according to IEC 61554. (0.51")
A VEGAMET in Ex version is an auxiliary, intrinsically safe instru-
Fig. 3: Mounting plate for wall mounting (VEGAMET 841, 842)
ment and may not be installed in explosion-endangered areas.
150 mm
Front panel mounting 5.91")
82 mm
Make sure that the cut-out required for mounting has a size of (3.23")

92 x 92 mm (3.63 x 3.63 in).
Slide the device into the panel cut-out from the front.
Press the two tensioning elements into the provided gaps.
Screw in the two screws of the tensioning elements evenly with a screw-
108 mm
(4.25")

(3.23")
82 mm

driver.

2
ø7 mm
(0.28")
ø13 mm
(0.51")

Fig. 4: Mounting plate for wall mounting (VEGAMET 861, 862)


3
Tube mounting
The optionally available mounting accessories are required for tube
mounting. The kit consists of two pairs of mounting brackets and four
mounting screws M6 x 100.
The mounting brackets are screwed to the mounting plate and the tube
as shown in the following illustration.
Loosen the four screws in the housing cover and open it to the left. Fas-
ten the device to the mounting plate using the screws (M5) supplied.
Fig. 2: Front panel mounting
1 Front panel, front plate or switching cabinet door 1 2 3 4 5
2 Clamping elements
3 Slotted screw

5.3 VEGAMET 841, 842, 861, 862


Mounting options
The field housing of the VEGAMET is equally suitable for outdoor or
indoor installation due to its degree of protection IP66/IP67 and Type 4X.
The standard version is designed for wall mounting. A mounting adapter
for pipe mounting is available as an option.

Wall mounting
Fix the mounting plate to the wall using the screws and dowels supplied
as shown in the figure below. Make sure that the arrows on the mounting
plate point upwards.
Loosen the four screws in the housing cover and open it to the left. Fas-
ten the device to the mounting plate using the screws (M5) supplied. Fig. 5: Tube mounting
1 VEGAMET
62826-EN-210818

2 Mounting plate
3 4 screws M6 x 100
4 Mounting brackets
5 Pipe for diameter 29 … 60 mm (1.14" to 2.36")

Controllers and communication 13


Mounting

Mounting sun shade


The optional sun protection can be used to protect against direct sun-
light. The sunshade is simply mounted between the mounting plate and
the controller, this is possible for both wall and pipe mounting.

1 2 3 4 5 6

Fig. 6: Mounting sun protection with pipe mounting


1 VEGAMET
2 Sun shade
3 Mounting plate
4 4 screws M6 x 100
5 Mounting brackets
6 Pipe for diameter 29 … 60 mm (1.14" to 2.36")

62826-EN-210818

14 Controllers and communication


Electrical connection

6 Electrical connection
6.1 Preparing the connection 6.3 Connection VEGAMET 142
Safety instructions
Always keep in mind the following safety instructions: 2 4 5 6
4
• The electrical connection must only be carried out by trained, quali-
fied personnel authorised by the plant operator.
• If overvoltage surges are expected, overvoltage arresters should be 1 1 2 3 3
installed.
Warning:
Only connect or disconnect in de-energized state.

6.2 Connection VEGAMET 141

1 1 2 3 2

61 62 63 8
+ -
5 41 42

+ - 64 65 66 9
6 43 44

L+ N-
7 91 92 67 68 69 10

Fig. 8: Wiring plan VEGAMET 142


61 62 63 5 1 Sensor input 1 (active/passive) 3)
2 Sensor input 2 (active/passive) 4)
3 HART sockets input 1 for connection of a VEGACONNECT
+ - 4 HART sockets input 2 for connection of a VEGACONNECT
3 41 42 5 4 … 20 mA current output 1
64 65 66 6 6 4 … 20 mA current output 2
7 Voltage supply of the controller
8 Relay output 1
L+ N- 9 Relay output 2
10 Relay output 3
4 91 92 67 68 69 7

Fig. 7: Wiring plan VEGAMET 141


1 Sensor input (active/passive) 2)
2 HART sockets for connection of a VEGACONNECT
3 4 … 20 mA current output
4 Voltage supply of the controller
5 Relay output 1
6 Relay output 2
7 Relay output 3
62826-EN-210818

2)
Passive input not available for Ex version
3)
Passive input 1 not available for Ex version Passive input 2 not available for Ex version
4)

Controllers and communication 15


Electrical connection

6.4 Connection VEGAMET 341 6.6 Connection VEGAMET 841

Relay Output Current


Power 1 2 3 Output Sensor
91 92 61 62 63 64 65 66 67 68 69 41 42 1 2 3

+ - + -
69 L N
68 6 1 2 3 4
67
66
3
- 42
65 5
64
3
+ 41
63 5
2 N- 92 62 4
1 L+ 91 61
1 2
Fig. 11: Wiring plan VEGAMET
1 Voltage supply of the controller
Fig. 9: Wiring plan VEGAMET 341 2 Relay outputs 1 … 3
1 Sensor input (active/passive) and HART sockets for connecting a 3 Current output
VEGACONNECT 5) 4 Sensor input (active/passive)
2 Voltage supply of the controller 5 Ground terminal for protective conductor
3 4 … 20 mA current output
4 Relay output 1 Details on the electrical connection can be found in the operating
5 Relay output 2 instructions of the device in the download area on our homepage.
6 Relay output 3
6.7 Connection VEGAMET 842
6.5 Connection VEGAMET 342
Current
Relay Output Output
Power 1 2 3 1 2 Sensor 1
91 92 61 62 63 64 65 66 67 68 69 41 42 43 44 1 2 3

+ - + - + -
L N
4
69
1 2 3
Sensor 2
2 68 8 4 5 6

6 67
5 - 44 66
5 + 43
4
- 42
65 7
5
4 + 41 64
3 63
2 N- 92 62 6
1 L+ 91 61
1 3 Fig. 12: Wiring plan VEGAMET
1 Voltage supply of the controller
2 Relay outputs 1 … 3
3 Current outputs 1/2
Fig. 10: Wiring plan VEGAMET 342 4 Sensor inputs 1/2 (active/passive)
1 Sensor input 1 (active/passive) 6) 5 Ground terminal for protective conductor
2 Sensor input 2 (active/passive) 7)
3 Voltage supply of the controller Details on the electrical connection can be found in the operating
4 4 … 20 mA current output 1 instructions of the device in the download area on our homepage.
5 4 … 20 mA current output 2
6 Relay output 1
7 Relay output 2
8 Relay output 3
62826-EN-210818

5)
Passive input not available for Ex version
6)
Passive input 1 not available for Ex version Passive input 2 not available for Ex version
7)

16 Controllers and communication


Electrical connection

6.8 Connection VEGAMET 861


Digital IN

2122 23 24 2526
5
1 2
Current
Power Relay Output Output
1 2 3 4 1 Sensor 1
91 92 61 62 63 64 65 66 67 68 69 70 71 72 41 42 1 2 3

+ - + -
L N

1 2 3 4

6 7

Fig. 13: Wiring plan VEGAMET


1 Voltage supply of the controller
2 Relay outputs 1 … 4
3 Current output
4 Sensor input (active/passive)
5 Digital inputs 1/2
6 Ground terminal for protective conductor
7 Ground terminal for cable screening sensor cable
8 Ground terminal for potential equalization

6.9 Connection VEGAMET 862


Digital IN

2122 23 24 2526 27282930 3132


5
1 2 3 4

Power Relay Output Current Output


1 2 3 4 5 6 1 2 3 Sensor 1
91 92 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 41 42 43 44 45 46 1 2 3

+ - + - + - + -
L N
4
1 2 3 Sensor 2
4 5 6

6 7

Fig. 14: Wiring plan VEGAMET


1 Voltage supply of the controller
2 Relay outputs 1 … 6
3 Current outputs 1 … 3
4 Sensor inputs 1/2 (active/passive)
5 Digital inputs 1 … 4
6 Ground terminal for protective conductor
7 Ground terminal for cable screening
8 Ground terminal for potential equalization
62826-EN-210818

Controllers and communication 17


Adjustment

7 Adjustment
7.1 Adjustment options and access protection
All controllers have an integrated display and adjustment unit. In addition,
the instruments can be parameterised via Bluetooth and corresponding
adjustment tools.
Adjustment via the display and adjustment unit
The adjustment is carried out menu-driven via four front keys or a turn/
push button as well as a clearly arranged, graphic-capable LC-display
with background lighting.
Wireless adjustment via Bluetooth
The integrated Bluetooth module enables wireless connection to smart-
phones/tablets (iOS/Android) or Windows PCs.
Operation is via a free app from the " Apple App Store", the " Goog-
le Play Store" or the " Baidu Store". Alternatively, adjustment can also be
carried out via PACTware/DTM and a Windows PC.

Fig. 15: Wireless connection to smartphone/table/notebook

Information:
Certain setting options are not possible or only possible to a
limited extent on site with the integrated display and adjustment
unit, for example the settings for flow measurement or pump
control. For these applications, the use of PACTware/DTM or the
VEGA Tools app is recommended. An overview of the available
applications and functions as well as their adjustment options can
be found in chapter " Selection criteria".

Access protection
Devices with a Bluetooth radio interface are protected against unwanted
access from outside. This means that only authorized persons can
receive measured and status values and change device settings via this
interface.

Protection of the parameterization


The settings (parameters) of the device can be protected against un-
wanted changes. The parameter protection is deactivated on delivery, all
settings can be made.
62826-EN-210818

18 Controllers and communication


Dimensions

8 Dimensions
VEGAMET 141, 142 VEGAMET 841, 842
121 mm
(4.76")
40 mm 113 mm
(1.57") (4.45")

(2.99")
76 mm
52 mm
(2.05")
108 mm

92 mm
(4.25")

(3.62")

46 mm
(1.81")

56 mm
(2.20")

111 mm
(4.37")
Fig. 16: Dimensions VEGAMET 141

121 mm
(4.76")
40 mm 113 mm 162 mm
(1.57") (4.45") (6.38")

Fig. 20: Dimensions VEGAMET 841, 842

160 mm
55 mm
(2.17")

(6.30")
82 mm 11 mm
(3.23") (0.43")
111 mm

92 mm
(4.37")

(3.62")

46 mm
(1.81")

56 mm
(2.20")

(0.27")
ø7 mm

ø13 mm
(0.51")
104 mm
(4.09")

(3.23")
82 mm

Fig. 17: Dimensions VEGAMET 142

VEGAMET 341, 342


111 mm 135 mm
(4.37") (5.31")
96 mm 118 mm 15,8 mm
Fig. 21: Dimensions Wall mounting VEGAMET 841, 842
(3.78") (4.64") (0.62")
142 mm
(5.59")
82 mm ca. 141 mm
(3.23") (5.55")
96 mm
(3.78")

ca. 177 mm
(3.23")

(2.76")

(6.97")
82 mm

71 mm

Fig. 18: Dimensions VEGAMET 341

111 mm 135 mm
(4.37") (5.31")
96 mm 118 mm 15,8 mm
198 mm
(3.78") (4.64") (0.62") (7.80")

Fig. 22: Dimensions Sun shade VEGAMET 841, 842

48...84 mm
96 mm
(3.78")

(1.89"...3.31")
20 mm 20 mm
(0.79") (0.79")
97 mm
(3.82")

82 mm
(3.23")

Fig. 19: Dimensions VEGAMET 342 ø 29


...60
mm
6")
"...2.3
(1.14
20 mm
(0.79")

(0.08")
2 mm

(0.08")

15 mm
2 mm

(0.59")
M6

Fig. 23: Dimensions Brackets for tube mounting VEGAMET 841, 842
62826-EN-210818

Controllers and communication 19


Dimensions

VEGAMET 861, 862


89,5 mm
(3.52")

136 mm
(5.35")

200 mm
(7.87")

Fig. 24: Dimensions VEGAMET 861, 862

198 mm
(7.79")
150 mm
5.91")
82 mm 11 mm
(3.23") (0.43")
(0.27")
ø7 mm

ø13 mm
(0.51")
128 mm

108 mm
(5.04")

(4.25")

(3.23")
82 mm

Fig. 25: Dimensions Wall mounting VEGAMET 861, 862

150 mm
(5.91")
82 mm ca. 178 mm
(3.23") (7.01")
217 mm
108 mm

(8.54")
(4.25")

(3.23")
82 mm

250 mm
(9.84")

Fig. 26: Dimensions Sun shade VEGAMET 861, 862

48...84 mm
(1.89"...3.31")
20 mm 20 mm
(0.79") (0.79")
97 mm
(3.82")

82 mm
(3.23")

mm
...60
ø 29 6")
"...2.3
(1.14
20 mm
(0.79")

(0.08")
2 mm

(0.08")

15 mm
2 mm

(0.59")
M6

62826-EN-210818

Fig. 27: Dimensions Brackets for tube mounting VEGAMET 861, 862

20 Controllers and communication


Notes
62826-EN-210818

Controllers and communication 21


Notes

62826-EN-210818

22 Controllers and communication


Notes
62826-EN-210818

Controllers and communication 23


All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information
available at the time of printing.
Subject to change without prior notice

© VEGA Grieshaber KG, Schiltach/Germany 2021


62826-EN-210818

VEGA Grieshaber KG
Am Hohenstein 113 Phone +49 7836 50-0
77761 Schiltach E-mail: [email protected]
Germany www.vega.com

You might also like