0% found this document useful (0 votes)
113 views36 pages

CMS-700 Brochure - English - October 2018

The Circuit Monitoring System (CMS) is an ultra-compact, high-performance multi-channel measurement system for monitoring AC and DC branch circuits in electrical distribution panels. It provides clear visibility of energy consumption at the branch level to enable power monitoring and energy efficiency analysis for buildings and critical power applications. The modular CMS system is scalable and flexible, with simple installation and commissioning, to meet various customer needs for retrofitting and upgrading electrical distribution systems.

Uploaded by

Julio Monteiro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
113 views36 pages

CMS-700 Brochure - English - October 2018

The Circuit Monitoring System (CMS) is an ultra-compact, high-performance multi-channel measurement system for monitoring AC and DC branch circuits in electrical distribution panels. It provides clear visibility of energy consumption at the branch level to enable power monitoring and energy efficiency analysis for buildings and critical power applications. The modular CMS system is scalable and flexible, with simple installation and commissioning, to meet various customer needs for retrofitting and upgrading electrical distribution systems.

Uploaded by

Julio Monteiro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

CMS – Circuit
Monitoring System
Give your buildings a new dimension

• Clear visibility of energy


consumption at branch level
• Easy retrofitting and upgrades
• Maximum reliabilty and security
thanks to encryption
• Simplified installation and
commissioning
• One sensor for all types of currents

The Circuit Monitoring System
(CMS) is a ultra-compact and high-
performance multichannel
measurement system for AC and
DC branch monitoring.
It represents a complete solution
for monitoring electrical
parameters in distribution panels,
enabling power monitoring and
energy efficiency analysis in
buildings and critical power
applications.
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 3


Table of contents

004 – 005 Give your buildings


a new dimension

006 – 007 CMS - Circuit Monitoring System

008 – 009 CMS System overview

010 CMS-700 Control Unit

012 – 013 Access to CMS-700

014 CMS-600 Control Unit

015 CMS sensors

016 – 017 Maximum compatibility

018 – 025 Applications

026 – 028 Technical data

029– 031 Technical specifications

032 – 033 Ordering information


4 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Give your buildings a new dimension
Scalable solutions for energy and asset management

With the rise of digitalization and the Internet of installation, electrical installers, building owners,
Things (IoT), collection of data from the entire facility and energy managers can choose services
network for analysis becomes easier, enabling ranging from on-site monitoring to cloud-based
optimization of energy usage and assets. From solutions. From design to operations stage,
monitoring energy consumption to control of hardware and software meet customers’ needs.
operations and costs, connectivity-based solutions “Give your buildings a new dimension” concept
can improve energy efficiency while reducing uses two proven energy monitoring solutions – the
costs. CMS-700 circuit-monitoring system and the
EQmatic energy analyser – and integrates their
To drive this digital transformation of public, functionalities with ABB’s Electrical Distribution
commercial and industrial buildings and their Control System (EDCS) via the ABB Ability cloud. To
power technologies ABB provides a scalable set up the network and cloud connectivity in a new
portfolio for energy and asset management. installation – or to upgrade existing facilities – just
Depending on specific requirements of the “plug & play” modules or devices are required.

Cloud Platform ABB AbilityTM

ABB AbilityTM

Modbus TCP

Ekip UP Ekip E-Hub

Water Gas Temperature

Modbus RS-485 Modbus TCP

Water

M-bus/RS-485
Gas

Temperature


Fully scalable portfolio of energy and asset management solutions
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 5

Upgrade
in 1 day

Save up to 30%
on operating costs

Save up to 20%
on energy bill
6 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


CMS - Circuit Monitoring System
Modularity and flexibility for every need

The CMS is a compact AC and DC multi-channel The design of the system guarantees reliability,
branch monitoring system, consisting of a control maximum ease of use, a wide measurement range
unit and sensors. The components can be easily (up to 160 A), and maximum scalability in any
installed and clearly arranged inside control and application, from critical power to buildings.
distribution cabinets, with minimum space Moreover, the high modularity and flexibility of
requirements. the CMS system makes it easy to upgrade and
expand the solution at any time, ideal for retrofit
applications in existing systems.

Main distribution

Electricity
meters

UPS system Inverters

Sub-distribution
boards

MCBs with
sensors

CMS control unit

Server room Production Ventilation, Lighting Solar panels


CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 7


Design and Specification

Energy transparency Maximum reliability and security


Clear visibility of energy consumption is made Utmost data security in CMS-700 thanks
possible at branch level. to encrypted SNMP v3 and SSL certificate.

OWNER
D E S I G N C O N S U LTA N T
E N G I N E E R I N G C O M PA N Y One sensor for all currents
Measurement of any kind of current –
direct, alternating or mixed-up to 160A


Installation

Minimum space requirements Simplified installation


Everything needed for effective measurement Save up to 30% of installation time thanks to
is available in ultra-compact sensors. quick mounting of sensors in only a few steps.

I N S TA L L E R
PA N E L B U I L D E R
S Y S T E M I N T E G R ATO R
Smart commissioning Easy retrofitting and upgrade
CMS system can be configured and put into The system can be extended or modified
operation in just a few minutes. at any time thanks to its flexibility and
modularity.


Operations

Up-to-date system status Increased responsiveness


Branch current monitoring to improve system Notification of alarms directly in the user
reliability and support continuous operations. mailbox through CMS-700 WebUI.

OWNER
ENERGY MANAGER
MAINTENANCE PROVIDER
FA C I L I T Y M A N A G E R Energy efficiency
Identification of optimal load distribution and
energy consumptions to reduce inefficiencies.
8 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


CMS System overview
Designed down to the finest detail

The quality of a measurement and monitoring Compactness, technology, measurement results,


system dependens on the strengths of the user friendliness and flexibility - every component
individual components and how well they interact. and every feature of the CMS has been fully
ABB's new CMS sets new and high standards. optimized in terms of practicality and functionality.


CMS-700 control unit in
combination with open
core CMS sensors.

CMS bus interface


Each bus interface allows up to 32 sensors
connected to the Control Unit:
CMS-700: up to 96 sensors (3 x 32)
CMS-600: up to 64 sensors (2x 32)

— —
CMS-600 CMS-700

Control Unit
The control unit evaluates the measurement data
picked up by the sensors, and makes it available
via the provided interfaces.

Two different units are available depending on the


application: CMS-600 and CMS-700.
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 9

Connection technology
Connecting the sensors to the control
unit is extremely easy and requires no
special tools. All sensors are connected
to the control unit via a flexible flat
cable and insulation piercing
connectors. The positioning of sensors
can be fully customized and placed
where measurement is required.

Sensors
CMS sensors can be placed anywhere in the
system, without any limitation. Easy initializing is
guaranteed by the unique ID assigned to each
sensors via Control Unit in just a few simple steps.
All measurement functions are available right after
commissioning.

Serial interfaces
Depending on the selected control unit, the
following communication interfaces are available:
RS485 (Modbus RTU), LAN (TCP/IP and Modbus
TCP) , SNMP v1/v2 and v3 encrypted.

The web server integrated in the CMS-700 makes it


possible to display the values via any Internet
browser and to automatically export the files (via
e-mail or FTP server).
10 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


CMS-700 Control Unit
Plug & Play energy monitoring

The CMS-700 control unit is the reliable solution for maximum


transparency of energy consumption.

Using CMS-700 it is possible to measure and implementation: Modbus RTU, Modbus TCP/IP and
calculate electrical parameters from both the SNMP, including encrypted SNMP v3 for utmost
mains and the branches, in order to provide the data security.
most comprehensive set of information on the
system. As well as helping in the identification of potential
savings related to energy consumption, CMS-700
A maximum of 3x32 sensors can be connected to allows to detect risky situations before they lead
the CMS-700, allowing to simultaneously obtain AC to service interruptions or load failures, improving
and DC current as well as active energy from up to system reliability and supporting continuous
96 branches. operations.
At the mains side, the control unit allows to access
the complete set of measurement data. Smart commissioning of the system is guaranteed
thanks to the CMS-700 integrated webserver, with
Complete set of embedded communication no need of any external software to put into
protocols is available to ensure smooth network operation the CMS system.

Energy monitoring using
the CMS-700 web server
interface
12 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Access to CMS-700
Integrated web server

Thanks to the CMS-700 built-in web server, any The integrated alarm function can be fully managed
web browser can be used to carry out the smart via the webserver ensuring quick notification, via
commissioning of the system, as well as easy email or FTP, to unusual system status. This impro-
visualization of online and historical measurement ves reactivity to potential issues and supports
data. continuous operations. The whole commissioning
phase of the CMS system can be carried out via
Every parameter from both mains and branches the CMS-700 WebUI, from the sensor identification
can be visualized as instantaneous or historical to the automatic data export settings. Moreover,
value, with intuitive graphs that allow the user to the WebUI enables the FW update of the control
quick analyze the measurement data. Data export unit at any time, ensuring to have the most advan-
to CSV files, mail or FTP is possible, according to ced functionalities and the most secure device.
user requirements.
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 13


Access to CMS-700
ABB Ability™ Electrical Distribution Control System

CMS-700 is automatically recognized in the ABB The ABB Ability™ Electrical Distribution Control
Ability™ Electrical Distribution Control System, System is an innovative cloud-computing platform
allowing the easy integration of its functionalities designed to make asset monitoring, control and
via the ABB Ability™ cloud. optimization simple, gathering data from the
devices installed in the power distribution system,
To set up the network and cloud connectivity in a including CMS-700.
new installation – or to upgrade existing facilities –
just “plug & play” modules or devices are needed. The cloud-based platform also provides access on
The cloud connection for the whole switchboard a multi-site level, simultaneously monitoring and
can be established via Emax 2 or Ekip UP equipped comparing the performance of different facilities,
with Ekip Com Hub, or through Ekip E-Hub DIN-rail as well as collecting and exporting data and
mounting module. historical trend analysis with on-demand queries
or scheduled automatic reports.
14 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


CMS-600 Control Unit
Compact current monitoring

The CMS-600 control unit is the compact solution for professional


monitoring of the currents of each individual line.

The CMS-600 is able to measure AC and DC Easy navigation of CMS-600 is ensured by the
currents of up to 64 branches. Up to 64 sensors highly intuitive touch screen display. It takes just a
can be installed on 2 independent lines to each few clicks to access al the desired functions and
control unit. menus. User does not require any special training
For quick and easy use, the control unit is neither for system commissioning nor for
equipped with an illuminated touch display that operation.
simplifies the parameterization and control of the
sensors. RS485 Modbus RTU interface allows users Ideal in simple monitoring applications, CMS-600
to remotely query and process measurement data, can be used to monitor current level of individual
making the CMS-600 control unit easy to be lines in order to easily detect load level and
integrated into an existing Modbus architecture. overload conditions.

1 2

3 4 5 6 7


Transparent navigation menu
1 Measurement | 2 Configuration | 3 Display of current measurement values |
4 Display of max./min. values and threshold | 5 Initialization/parameterization
of the sensors | 6 Modbus configuration | 7 Display settings
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 15


CMS sensors
High-level performance in a tiny space

Available in 18 or 25mm versions, CMS sensors guarantee maximum


performance with ultimate compactness.

— Reduced size, high performance: alternating (AC), measurement data is transmitted in digital format
* All accuracy
specifications refer to the continuous (DC) or mixed (TRMS) currents - CMS to the control unit via the bus interface. This
relevant full scale value sensors detect and measure all types of currents minimizes the amount of cables required in the
and apply at 25° C.
up to 160A (TRMS). switchboards and maximizes the reliability of the
measured value transmission.
Since each sensor is equipped with its own
microprocessor for signal processing, the

A A A

— — —
Alternate Current (AC) Direct Current (DC) Mixed current

— —
Open- core sensor Solid-core sensor 18 mm 25 mm

Open-core sensors Solid-core sensors


The special U-shape form of the open-core sensors Available in 18mm and 25mm types, solid-core
allows the retrofitting of existing installation, sensors offer AC measurement accuracy* of ≤ ± 0.5
making sensors easy to adapt to different %. This accuracy makes solid-core sensors suitable
applications while keeping continuity of service. for all applications where high measurement
AC accuracy* of ≤ ± 1,0 % allows open-core sensors precision is needed.
to be used in various monitoring applications.
16 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Maximum compatibility
Mounting flexibility for simple integration

Depending on the application, you can choose between two sets of sensors - one
specifically designed for ABB installation devices, the other with an universal design
to be installed on cables or DIN-rail.


Sensors for ABB devices

System pro M
installation,
SMISSLINE
The sensors of
the CMS-120LA
and CMS-120FH
series can be
used for easy
retrofit
installation on
S200 MCBs,
SMISSLINE
devices and E90
fuseholders
(1000VDC).

Mounting on
S800 devices
The sensors of
the CMS-100S8
and CMS-200S8
series can be
mounted on all
S800 high-
performance
switches with
cage terminals.
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 17


Universal sensors

Mounting on
DIN-Rail
The sensors of
the CMS-120DR,
CMS-100DR and
CMS-200DR
series are
installed directly
on a DIN rail using
an enclosed
adapter.

Clamp mounting
on the cable
If space is a
problem, the
sensors of the
CMS-120CA
series, CMS-CMS-
100CA and 200CA
can be fixed
directly on the
cable to be
measured using
clamps (not
supplied).
18 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Applications
Flexibility and modularity

— Hyperscale

The CMS range offers users a


simple and compact solution to
guarantee energy efficiency and
Colocation
up-to-date system status, Data
responding to the specific needs of Centers

different customers.
Financial services
The design of the CMS system is based on
extreme flexibility and modularity, making it
suitable for applications in different sectors.

In data centers, CMS system can be installed Offices


to get clear visibility of energy consumption
and detect risky situations before they lead to Hotels
service interruptions or load failures.

Retrofitting at single branch level allows to Shopping


carry out brownfield extension in existing malls
Commercial
installations at any time.
Buildings
Retail
Commercial and public buildings can also
leverage the CMS system to achieve higher
energy efficiency and to have more detailed Chain stores
monitoring of their facility.

Offices, shopping malls, hotels, retail or chain


stores can increase their awareness of energy
consumption to improve performance.
Schools
Public facilities, such as schools, sport
centers and healthcare facilities, can secure
service continuity and develop predictive
maintenance forecasts.
Sport
Centers
Public
facilitites

Healthcare
facilities
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 19
20 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Applications
Current and power monitoring in data centers

Within critical power applications such as data master tap-off unit to measure the incoming
centers, CMS-700 provides a reliable solution side. Open-core CMS sensors are integrated
for measuring individual branch load circuits into daisy-chained slave tap-off units to carry
and presenting energy and power dashboards. out energy monitoring of every single phase to
In addition, it protects data centers against the rack PDU.
current-related system outages with an
integrated alarm function. The integrated webserver ensures an easy
configuration and allows you to remotely check
In this example the busbar trunking system, realtime online values as well as historical data
mounted overhead or under the raised floor of without any additional external software.
the server racks, is equipped with master and On the other hand, Modbus and SNMP commu-
slave plug-in tap-off units. The proposed nication protocols allow the easy integration
solution, suitable for new and existing instal- into higher level systems like DCIM or SCADA.
lations, includes CMS-700 control unit in the

Design and Specification


Through this solution, the customer can simply and
easily ensure optimal load distribution and efficient
energy consumption

Installation
I can easily extend the solution when expanding
the busbar trunking system, as well as retrofit into
existing installations.

Operation
I can reduce downtime and improve system
reliability by early detecting potential issues.
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 21

RJ45 Ethernet cable


CMS bus

Web server

MASTER SLAVE SLAVE


TAP-OFF UNIT TAP-OFF UNIT TAP-OFF UNIT

CMS-700 + Open CTs Existing MCB Existing MCB


on MCBs
22 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Applications
Multi-site supervision for chain stores

Stores can be situated as single locations or as are gathered from dedicated meters and sent
a shop in a shopping mall. digitally to the E-Hub.
Electrical data and measurements are collected
Current solutions gather data from all the from energy meters, breakers and CMS-700
different stores in order to analyze energy devices and transmitted to the E-Hub via
management, monitor energy consumption and Modbus RTU. At the core of the solution, the
improve energy efficiency. To aggregate and Ekip E-Hub mounted on the DIN rail gathers all
compare data from multiple locations, a cloud- the incoming data.
based solution is essential.
Data from all the stores then goes to the cloud
Monitoring any store requires only an analogue via Ethernet or wireless connections for further
installation. Water and gas consumption data analysis.

Design and Specification


While guaranteeing fast payback, this solution can ensure
compliance or higher class on efficiency standards.

Installation
Deploying a multi-site monitoring solution,
I can reduce installation time and components.

Operation
Introducing a single intuitive digital solution,
I can guarantee continuous operation and allocate
effectively energy consumptions.
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 23

Power Internet cloud


RJ45 Ethernet cable
Digital Inputs
Modbus RTU
CMS bus

STORE 1 Ethernet Switch STORE 2 Ethernet Switch


TCP/IP TCP/IP

Ekip E-Hub Ekip E-Hub

CMS-700 + CMS-700 +
Open CTs on Open CTs on
MCBs MCBs
RTU

RTU

Water Water
CMS bus CMS bus

Gas Gas

Water Water
Existing MCB Existing EQ meter Existing MCB Existing EQ meter
breaker breaker
Gas Gas
24 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Applications
Retrofitting and upgrading public buildings

For public buildings such as schools, a retrofit The breakers measure energy and power quality,
solution can bring rapid benefits without while Ekip Signalling modules send information
replacing existing components. about status, alarms and the number of operations.

With accurate performance monitoring of the The CMS-700 in the panel is responsible for
installation, devices can be managed more branch monitoring and is connected to the Ekip
efficiently, producing savings in maintenance UP via Modbus TCP/IP. In order to monitor
and energy costs. consumption, another panel is provided with the
Ekip E-Hub to gather data from gas, water and
In this scenario, the Ekip UP and the Ekip E-Hub energy meters and from breakers.
collect data from field devices.
This data, together with information collected by
The Ekip UP is connected to the breakers and, the Ekip UP, then goes to the cloud and is made
via an Ethernet switch, to the Ekip Signalling. available on ABB Ability EDCS for further analysis.

Design and Specification


I will easily upgrade the existing facilities,
ensuring a very fast payback.

Installation
Through plug&play components and commissioning,
I can upgrade the existing distribution and panel
boards. I don't have to replace anything.

Operation
With this solution I can start saving on operating costs,
also on multi-site, through an intuitive and simple
solution while catching up with efficiency standards
and regulations.
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 25

Internet cloud Power


RJ45 Ethernet cable
Digital Inputs
CMS bus

MAIN PANELBOARD
DISTRIBUTION
BOARD Ekip UP +
Open CTs
Ethernet Switch Ethernet Switch

Ekip Signalling CMS-700 + Ekip Signalling


Existing Modbus TCP Open CTs on Modbus TCP
breaker MCBs

CMS bus

Existing Existing Existing Existing MCB


breaker breaker breaker

Technical data
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 27


CMS components overview

Specifications CMS-600 Control Unit CMS-700 Control Unit

CMS Sensors
Sensors 64 (2x32) 96 (3x32)

Control Unit
Direct power supply 80-277 V AC
Power supply via external 24 V DC power supply
Voltage measurement
Current measurement (via external CT)
Active, reactive and apparent power measurement (via external CT)
Power

Values calculated for individual sensors


Power (uses the current measured by the sensor, taking the voltage
and the power factor over time from the control unit)
Power (uses the current measured by the sensor, taking the voltage
and the power factor from the control unit)

Interface
RS485
LAN

Protocols
Modbus RTU
Modbus TCP/IP
SNMP (v1, v2 and v3 encrypted)

Visualization
Integrated web server
Touch display
Exporting CSV data

Certifications
IEC 61010-1
UL 508/ CSA C22.2 No. 14
28 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


CMS components overview


Sensors overview

System Pro M, SMISSLINE S800 DIN rail Cable tie

Mounting method for all MCBs, RCDs, for MCBs for fuse for all S800 devices with universally universally
RCBOs with (S200, SMISSLINE) and RCBOs holders E90 cage terminals usable usable
twin terminals (SMISSLINE)

Open-core sensors

AC accuracy* of ≤ ± 1.0%

The laying method


influences the accuracy.

18-mm overall width

CMS-120xx (80 A) CMS-120PS CMS-120LA - CMS-120DR CMS-120CA

CMS-121xx (40 A) CMS-121PS CMS-121LA CMS-121FH CMS-121DR CMS-121CA

CMS-122xx (20 A) CMS-122PS CMS-122LA CMS-122FH CMS-122DR CMS-122CA

Solid-core sensors

AC accuracy* of ≤ ± 0.5%

18-mm overall width

CMS-100xx (80 A) CMS-100PS CMS-100S8 CMS-100DR CMS-100CA

CMS-101xx (40 A) CMS-101PS CMS-101S8 CMS-101DR CMS-101CA

CMS-102xx (20 A) CMS-102PS CMS-102S8 CMS-102DR CMS-102CA

25-mm overall width

CMS-200xx (160 A) CMS-200S8 CMS-200DR CMS-200CA

CMS-201xx (80 A) CMS-201S8 CMS-201DR CMS-201CA

CMS-202xx (40 A) CMS-202S8 CMS-202DR CMS-202CA

* All accuracy specifications refer to the relevant full scale value and apply to 25°C
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 29


Technical specifications


CMS-600 Control Unit

Supply voltage [V DC] 24 (± 10 %)


Power loss [W] 4-24 (depending on the number of sensors)
Interface 2-wire RS485
Protocol Modbus RTU

CMS-600 Data transmission speed [Baud] 2400… 115200
Refresh time ≤1 sec. with max. 64 sensors
Insulation voltage [V AC] 400
Screw terminals 0.5 ... 2.5 mm2, max. 0.6 Nm
Installation method 35-mm DIN Rail (DIN 50022)
Dimensions [mm] 71.8 x 87.0 x 64.9 (4 DIN modules)
Operating temperature [°C] − 25 ... +70
Storage temperature [°C] − 40 ... +85
Reference standards IEC 61010-1
UL 508/CSA C22.2 no. 14


CMS-700 Control Unit

IEC61010-1
Supply voltage [VAC] 90-240 (L1-N)
Voltage measurement range [VAC] 90-240 (L1-N, L2-N, L3-N)
UL 508 / CSA C22.2 No. 14

Supply voltage [VAC] 80-277 (L1-N)
CMS-700
Voltage measurement range [VAC] 80-277 (L1-N, L2-N, L3-N)
General
Frequency [Hz] 50 / 60
Power consumption (L1-N) [W] 5 ... 40 (depending on the number of sensors)
Measurement range, current transformer, nominal: 5
secondary side A max: 6
Modbus RTU data rate [Baud] 2-wire RS485, 2400 ... 115200
Data update speed ≤1 sec. with max. 96 sensors
LAN [Mbit/s] 100
Cable cross-section [mm 2] 1.0.. 2.5 mm², max. 0.8 Nm
Installation method 35-mm DIN Rail (DIN 50022)
Protection degree IP20
Overvoltage category II
Altitude [m] 2000
Dimensions [mm] 160.0 x 87.0 x 64.9 (9 DIN modules)
Operating temperature [°C] − 25 ... +60
Storage temperature [°C] − 40 ...  +85
Standards
Electrical safety IEC 61010-1, UL 508, CSA C22.2 No.14
EMC EC61326-1

Mains accuracy
Voltage ± 1 %
Current ± 1 % 
Harmonic components (up to 2500Hz) ±1%
Active power ± 2 %
Apparent power ± 2 %
Reactive power ± 2 %
Power Factor ± 0.2 %
30 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Technical specifications


Open core sensors 18 mm

Sensor type CMS-120xx CMS-121xx CMS-122xx


Measurement range [A] 80 40 20
— Measurement method TRMS, AC 50 / 60 Hz, DC
CMS-120LA
Peak value of the distorted wave-form ≤ 1.5 ≤3 ≤6
AC accuracy (TA = 25 °C)* ≤ ± 1 %
AC* temperature coefficient ≤ ± 0.04 %
AC accuracy (TA = 25 °C)* ≤ ± 1.2 % ≤ ± 1.4 % ≤ ± 1.8 %
DC* temperature coefficient ≤ ± 0.14 % ≤ ± 0.24 % ≤ ± 0.44 %
— Resolution [A] 0.01
CMS-120FH
Internal sampling rate [Hz] 5000
Respond time (±1 %) [sec] Type 0.34
Max. diameter of the cable [mm] 9.6
Insulation 690 V AC  /1500 V DC
— Operating temperature [°C] − 25 ... +70 / − 40 ... + 85
CMS-120PS
Size CMS-120PS series [mm] 17.4 x 41.0 x 26.5
CMS-120CA series [mm] 17.4 x 41.0 x 29.0
CMS-120DR series [mm] 17.4 x 51.5 x 43.2
CMS-120LA series [mm] 17.4 x 41.0 x 38.9
CMS-120FH series [mm] 17.4 x 41.0 x 38.9

— Reference standard IEC 61010-1 | UL508 / CSA C22.2 No 14


CMS-120DR * All accuracy specifications refer to full scale value and apply at 25° C.
In the case of open-core sensors, the position of the cable affects accuracy.


CMS-120CA

Solid-core sensors 18 mm

Sensor type CMS-100xx CMS-101xx CMS-102xx


Measurement range [A] 80 40 20
Measurement method TRMS, AC 50 / 60 Hz, DC

CMS-120PS Peak value of the distorted wave-form ≤ 1.5 ≤3 ≤6
AC accuracy (TA = 25 °C)* ≤ ± 0.5 %
AC* temperature coefficient ≤ ± 0.036 %
AC accuracy (TA = 25 °C)* ≤ ± 0.7 % ≤ ± 1.0 % ≤ ± 1.7 %
DC* temperature coefficient ≤ ± 0.047 % ≤ ± 0.059 % ≤ ± 0.084 %
Resolution [A] 0.01

CMS-120PS Internal sampling rate [Hz] 5000
Respond time (±1 %) [sec] Type 0.25
Max. diameter of the cable [mm] 10
Insulation [V] 690 V AC /1500 V DC
Operating temperature [°C] − 25 ... +70 / − 40 ... + 85
Size CMS-100PS series [mm] 17.4 x 41.0 x 26.5

CMS-100S8 series [mm] 26.5 x 45.5 x 31.8
CMS-120DR
CMS-100DR series [mm] 17.4 x 51.5 x 43.2
CMS-100CA series [mm] 17.4 x 41.0 x 29.0
Reference standard IEC 61010-1 | UL508 / CSA C22.2 No 14
* All accuracy specifications refer to the relevant full scale value and apply at 25° C.


CMS-120CA
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 31


Solid-core sensors 25 mm

Sensor type CMS-200xx CMS-201xx CMS-202xx


Measurement range [A] 160 80 40
Measurement method TRMS, AC 50 / 60 Hz, DC

CMS-120PS
Peak value of the distorted wave-form ≤ 1.5 ≤3 ≤6
AC accuracy (TA = +25°C)* ≤ ± 0.5 %
AC* temperature coefficient ≤ ± 0.036 %
AC accuracy (TA = +25°C)* ≤ ± 0.7 % ≤ ± 1.0 % ≤ ± 1.7 %
DC* temperature coefficient ≤ ± 0.047 % ≤ ± 0.059 % ≤ ± 0.084 %
Resolution [A] 0.01
— Internal sampling rate [Hz] 5000
CMS-120DR
Respond time (±1 %) [sec] Type 0.25
Max. diameter of the cable [mm] 15
Insulation [V] 690 V AC /1500 V DC
Operating temperature [°C] − 25 ... +70 / − 40 ... + 85
Size CMS-200S8 series [mm] 26.5 x 43.0 x 38.5
— CMS-200DR series [mm] 25.4 x 43.0 x 43.2
CMS-120CA
CMS-200CA series [mm] 25.4 x 43.0 x 35.7
Reference standard IEC 61010-1 | UL508 / CSA C22.2 No 14
* All accuracy specifications refer to the relevant full scale value and apply at 25 °C.
32 CMS – CIRCU IT MO N ITO RIN G SYST EM GIV E YOUR BUILDIN GS A N EW DIMEN SION


Order information


Open-core sensors

Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)

Open-core sensors 18 mm for retrofit of MCBs (S200, SMISSLINE) and RCBOs (SMISSLINE)
80 A CMS-120LA 2CCA880225R0001 0.012 1
40 A CMS-121LA 2CCA880226R0001 0.012 1
20 A CMS-122LA 2CCA880227R0001 0.012 1

Open-core sensors 18 mm for retrofit of E90 fuseholders 1000VDC


40 A CMS-121FH 2CCA880216R0001 0.012 1
20 A CMS-122FH 2CCA880217R0001 0.012 1

Open-core sensors 18 mm for pro M and SMISSLINE devices with twin terminals
80 A CMS-120PS 2CCA880210R0001 0.012 1
40 A CMS-121PS 2CCA880211R0001 0.012 1
20 A CMS-122PS 2CCA880212R0001 0.012 1

Open-core sensors 18 mm for DIN-rail (universal use)


80 A CMS-120DR 2CCA880240R0001 0.015 1
40 A CMS-121DR 2CCA880241R0001 0.015 1
20 A CMS-122DR 2CCA880242R0001 0.015 1

Open-core sensors 18 mm for cable tie mounting (universal use)


80 A CMS-120CA 2CCA880220R0001 0.011 1
40 A CMS-121CA 2CCA880221R0001 0.011 1
20 A CMS-122CA 2CCA880222R0001 0.011 1


Solid-core sensors

Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)

Solid-core sensors 18 mm for S800 devices with cage terminals


80 A CMS-100S8 2CCA880124R0001 0.014 1
40 A CMS-101S8 2CCA880125R0001 0.014 1
20 A CMS-102S8 2CCA880126R0001 0.014 1

Solid-core sensors 18 mm for pro M & SMISSLINE installation devices with twin terminals
80 A CMS-100PS 2CCA880100R0001 0.012 1
40 A CMS-101PS 2CCA880101R0001 0.012 1
20 A CMS-102PS 2CCA880102R0001 0.012 1

Solid-core sensors 18 mm for DIN rail mounting (universally usable)


80 A CMS-100DR 2CCA880128R0001 0.015 1
40 A CMS-101DR 2CCA880129R0001 0.015 1
20 A CMS-102DR 2CCA880130R0001 0.015 1

Solid-core sensors 18 mm for cable tie mounting (universally usable)


80 A CMS-100CA 2CCA880107R0001 0.011 1
40 A CMS-101CA 2CCA880108R0001 0.011 1
20 A CMS-102CA 2CCA880109R0001 0.011 1

Solid-core sensors 25 mm for S800 devices with cage terminals


160 A CMS-200S8 2CCA880136R0001 0.028 1
80 A CMS-201S8 2CCA880137R0001 0.028 1
40 A CMS-202S8 2CCA880138R0001 0.028 1
CMS – CIRCU IT MO N ITO RIN G SYST EM GIVE YOUR BUIL DINGS A NEW DIM ENSION 33


Solid-core sensors

Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)

Solid-core sensors 25 mm for DIN-rail mounting (universal use)


160 A CMS-200DR 2CCA880132R0001 0.030 1
80 A CMS-201DR 2CCA880133R0001 0.030 1
40 A CMS-202DR 2CCA880134R0001 0.030 1

Solid-core sensors 25 mm for cable tie mounting (universal use)


160 A CMS-200CA 2CCA880117R0001 0.026 1
80 A CMS-201CA 2CCA880118R0001 0.026 1
40 A CMS-202CA 2CCA880119R0001 0.026 1


Control Unit

Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)
CMS-600 Control Unit CMS-600 2CCA880000R0001 0.153 1
CMS-700 Control Unit CMS-700 2CCA880700R0001 0.329 1


Accessories

Description
Type ABB code Weight of 1 unit (kg) Unit conf. (Pcs)
2 m flat cable CMS-800 2CCA880148R0001 0.017 1
5 m flat cable CMS-802 2CCA880331R0001 0.045 1
10 m Flat cable CMS-803 2CCA880332R0001 0.090 1
30 m Flat cable CMS-805 2CCA880333R0001 0.270 1
Connector set (35 pcs) CMS-820 2CCA880145R0001 0.024 35
Further information
We reserve the right to make technical
modifications and change the contents of
this document without notice.
ABB does not assume any liability for the
presence of possible errors or insufficient
information in this document.

All rights to this document, texts and


illustrations contained therein are
reserved. Reproduction, disclosure to
third parties or the use of the contents of
this document, in whole or in part,
without the prior written authorization of
ABB is prohibited.

ABB Group

Electrification Products Division


Business Unit Building Products

www.abb.com/lowvoltage

2CCC481003C0202 - Rev B 05.2018

© Copyright 2018 ABB. All rights reserved.


Specifications are subject to change without notice.

You might also like