Mindray

The document discusses the differences between 3-part and 5-part hematology analyzers. 5-part analyzers can differentiate and provide counts for lymphocytes, monocytes, neutrophils, eosinophils, and basophils while 3-part analyzers cannot differentiate some of these cell types. The document also provides technical specifications for the BC-5140 5-part auto hematology analyzer.

Uploaded by

Lupe Perez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views2 pages

Mindray

The document discusses the differences between 3-part and 5-part hematology analyzers. 5-part analyzers can differentiate and provide counts for lymphocytes, monocytes, neutrophils, eosinophils, and basophils while 3-part analyzers cannot differentiate some of these cell types. The document also provides technical specifications for the BC-5140 5-part auto hematology analyzer.

Uploaded by

Lupe Perez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Why do we need 5-part hematology analyzers?

WBC differential: 3-part WBC differential: 5-part


Technical Specifications: Display
10.4 inch TFT Touch Screen
BC-5140
Principles Auto Hematology Analyzer
Impedance method for RBC and PLT counting

Lymphocyte
Cyanide free reagent for hemoglobin test Multi-language
A “CUTE”5-part
?
Basophil Flow Cytometry (FCM) +Tri-angle laser scatter + Chemical dye Chinese, English, Spanish, Portuguese, Russian, French, Bahasa Indonesia
Mid-size cell Neutrophil DIFF WBC
Eosinophil method for WBC 5-part differential analysis and WBC counting
Data Storage Capacity
Monocyte
Parameters Up to 200,000 results including numeric and graphical information
Monocyte
25 reportable parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%,
Neutrophil Communication
Lymphocyte Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC,
LAN Port supports HL7 protocol
RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC.
0 100 200 300 FL Eosinophil Basophil 12 Research parameters include LIC%, LIC#, ALY%, ALY#, PLT Interface
Clumps#, PLT Clumps%, Lip#, Lip%, NRBC#, NRBC%, Blast#, Blast%
USB, LAN
3 histograms for WBC, RBC and PLT
3-part hematology analyzers can not differentiate Basophil, 5-part hematology analyzers can provide Lymphocyte, Support bi-directional LIS
3 scattergrams for WBC differential
Eosinophil and Monocyte. Additionally, Lymphocyte and Monocyte, Neutrophil, Eosinophil and Basophil results for
Neutrophil results are easily affected by abnormal cells. every sample. Additionally, the 5-part results are less affected Printout
by abnormal cells. Reagent External Thermal printer/Laser printer / Inkjet printer, various printout
formats and User-defined formats
M-52D Diluent, M-52DIFF lyse, M-52LH lyse, probe cleanser
Flag information: 3-part Flag information: 5-part
Performance Operating Environment
Temperature: 10°C~30°C
WBC DIFF
Parameter Linearity Range Precision Carryover
LAS

LIC
WBC 0-500×109/L ≤2% (4-15×109/L) ≤0.5% Humidity: 20%~85%
R2 RBC 0-8×10¹²/L ≤1.5% (3.5-6.0×10¹²/L) ≤0.5%
LIC Air pressure: 70kPa~106kPa
R3 WBC HGB 0-250g/L ≤1.5% (110-180g/L) ≤0.6%
MON NEU LIC

PLT 0-5000×109/L ≤6.0% (100-149×109/L) ≤1.0%


ALY EOS
≤4.0% (150-500×109/L) Power requirement
Rm
LYM
100V-240V
Nrbc
Sample Volume
50Hz/60Hz
0 100 200 300 FL GHO Prediluted mode 20 μL
MAS Whole blood mode 15 μL
Capillary whole blood mode 15 μL Dimension and Weight
WBC histogram only indicates regional abnormal graph, it can't 5-part hematology analyzers provide more detailed and Depth*width*height: 400mm*320mm*410mm
bring specific flags for different clinical cases. specific flag information. Users are able to clearly understand Throughput Weight: 24kg
the clinical significate of flags and make a decision. 60 samples per hour

Users are able to access our tailored innovation and intelligent diagnosis support to

She said: “we upgraded to a 5-part hematology analyzer 3 months ago, and it’s been working very well. Our
lab has lots of abnormal samples, such as Eosinophilia and Monocytosis samples. We could only get the
information that the mid-size cells percentage was higher than normal level, but couldn’t distinguish which
kind of cells increased exactly. Now, the 5-part hematology analyzer provides flags directly, which reduces
www.mindray.com
smears need to be reviewed, and significantly improves our work efficiency.”
P/N: ENG-BC-5140-210285x6P-20171017
Dr Marisela Ramos, lab manager ©2017 Shenzhen Mindray Bio-Medical Electronics Co.,Ltd. All rights reserved.
BC-5140
Auto Hematology Analyzer
4 USB ports are located on the instrument’s left side. They permit
BC-5140, the 5-part hematology analyzer offers a great solution for clinical labs, especially for those who have limited
BC-5140 users to transmit data conveniently and connect with printers,
space. Its compact foot-print is a result of innovative technology improvements, including miniaturized semi-conductor
keyboard, mouse, barcode scanner, etc.
laser source, highly integrated electronic boards and optimized liquid handling system.
Based on Mindray’s continuous innovation in hematology field, BC-5140 is especially tailored to assist diagnostic labs who
need full CBC + 5-part results, with relatively low daily sample volume, restricted lab space and tight budget.

Compact
As the lightest and most compact 5-part hematology analyzer so far from Mindray, BC-5140 is a highly user-friendly and Lab Test Requisition

innovative analyzer that offers cost efficient CBC and 5-part white cell differential results. It is targeted to fulfil and exceed Two kinds of lyse reagents are located inside of BC-5140, which helps Test Results BC-5140 supports bi-directional LIS with test results and patient
LIS Driver
Plug-in Patient Information
the demands of our global customers by providing more accurate, more efficient and more innovative solutions for labs. the small labs to save space. information. HL7 protocol is supported as well.

Test Results Transmitted

WBC 5-part differentiation, 25 reportable parameters and 12 research parameters, 3 histograms and 3 scattergrams Whole
blood mode, Capillary whole blood mode and Prediluted mode
Tri-angle Laser scatter + Chemical dye + Flow cytometry technology Technology
Dedicated optical counting channel for Basophil measurement Utility
Powerful capability of flagging abnormal cells Compared with traditional helium neon laser or argon laser,
The 10.4 inch TFT touch screen with a wide viewing angle, brings
10.4 inch large TFT touch screen with user-friendly software semi-conductor laser has smaller size, lower cost and longer life cycle.
convenience to clinicians. Users can complete all instrument operations
Large storage capacity: up to 200,000 samples
on the screen, practically eliminating the need for an external PC.
Throughput: 60 samples per hour
Sample volume is only 15μ L which is ideal for pediatrics

Improved DC impedance technology is used to count and size the RBC


BC-5140 inherits it’s convenient and proven powerful software design
and PLT. The smaller counting aperture (50μm in diameter) provides
from BC-6800 and BC-3600 platforms, the friendly interface is ideal for
Tri-angle laser scatter + focused flow + chemical dye, creating the possibility for a better 5-part WBC differentiation even better performance on samples with low PLT.
small sized labs.
on samples with high Eosinophil.

MAS

Running capillary blood through the sample probe directly is more Only three routine reagents are required. These have 2 years shelf
LAS
convenient for the users in children’s hospitals, etc. For Prediluted life and also less consumed by BC-5140. Original QC and calibrator
mode, BC-5140 has higher dilution ratio than other 5-part hematology are also provided to ensure the hematology analyzer’s traceability
WAS
LAS shows cellular volume
MAS shows cellular complexity
analyzers, thus it brings a better mixing effect. and testing quality.