Annexure – I
PUMP PERFORMANCE
1 Manufacturer -
2 Type of Pump -
3 Model -
5 Rated Head m
8 BkW kW
9 Shut-off Head m
19 Speed rpm
20 No. of stages -
Annexure II
OFFERED BY
Sl. No. Parameter
BIDDER
MATERIAL OF CONSTRUCTION
1 Pump Casing
2 Impeller
3 Gland packing
4 Shaft
5 Motor casing
6 Column pipe
7 Discharge Elbow
10 Fasteners
CONSTRUCTION OF PUMPSET
13 Type of Impeller
16 Seal Arrangement
Note : Lubrication for line shaft bearing is external forced water lubrication which is mandatory
for all the pumps.
CONTRACTOR 17/53 SUPERINTENDING ENGINEER
SECTION-V PUMPS & ELECTRO MECHANICAL WORKS PUMPS & MOTORS
Annexure – III
Sl. Declaration
Description Remarks
No. Yes No
1 Pump manufacturer.
8 No of Casing
9 Pump Efficiency @ duty point
10 bkW @ duty point
11 Maximum Pump
Input throughout the
12 Rated Motor Efficiency
Over All Pump set Efficiency @
13
duty point
14 Motor Input @ Duty Point
15 Motor Rating kW
mm2 x _Cores x
Runs
Power
Cables
mm2 x Cores x
25 MoC of Impeller
If any additional particulars are necessary or the particulars are given in some other form the same
may be enclosed separately.
The contractor shall give all the particulars. The tender, may be considered as non-responsive, if
important particulars are not submitted.
9.16.2 HT Switchgear
1 General Particulars
a) Name of Panel manufacturer
b) Construction compartmentalised or
non-compartmentalised
c) Sheet metal thickness
d) Degree of protection
3 I) Material of busbars
ii) Busbar size
Phase
Neutral
5 Protection relays
a) Make
b) Type
6 Control Wiring
a) Size
b) Type
c) Insulation
d) Voltage grade
7 Control Terminals
a) Make
b) Type
c) Voltage Grade
d) Current rating
e) Minimum 10 % spare terminal furnished
8 Push Buttons
a) Make
b) Type
c) No. & Rating of Contacts
9 Indicating Lamps
a) Make
b) Type
c) Rating
10 Integrating Meters
a) Make
b) Type
c) Accuracy Class
d) VA Burden
11 Current Transformers
a) Make
b) Type
c) Core Details (Current ratio, VA Burden,
Accuracy, RCT and VK)
Core 1:
Core 2:
Core 3:
12 Potential Transformers
a) Make
b) Type
c) Core Details (Voltage ratio, VA Burden, and
Accuracy)
Core 1:
Core 2:
13 Terminal Blocks
a) Make
b) Type
c) Current rating
d) Voltage Grade
e) Suitable for 2 Nos. Cu 2.5.mm2 wire
14 H.T. Capacitors
a) Make
b) Type
3 I) Material of busbars
ii) Busbar size
Phase
Neutral
c) rating
5 Protection relays
a) Make
b) Type
6 Control Wiring
a) Size
b) Type
c) Insulation
d) Voltage grade
7 Control Terminals
a) Make
b) Type
c) Voltage Grade
d) Current rating
e) Minimum 10 % spare terminal furnished
8 Push Buttons
a) Make
b) Type
c) No. & Rating of Contacts
9 Indicating Lamps
a) Make
CONTRACTOR 91/97 SUPERINTENDINGENGINEER
SECTION – V PUMPS & ELECTRO – MECHANICAL WORKS ELECTRO-MECHANICAL WORK
b) Type
c) Rating
10 Integrating Meters
a) Make
b) Type
c) Accuracy Class
d) VA Burden
11 Current Transformers
a) Make
b) Type
c) Core Details (Current ratio, VA Burden,
Accuracy, RCT and VK)
Core 1:
Core 2:
Core 3:
12 Potential Transformers
a) Make
b) Type
c) Core Details (Voltage ratio, VA Burden, and
Accuracy)
Core 1:
Core 2:
13 Terminal Blocks
a) Make
b) Type
c) Current rating
d) Voltage Grade
e) Suitable for 2 Nos. Cu 2.5.mm2 wire
Name of Manufacturer
a) Make
b) Type
a) Make
b) Type
4 Selector Switch
a) Make
b) Type
5 Push Buttons
a) Make
b) Type
6 Indicating Lamps
a) Make
b) Type
7 Integrating Meters
a) Make
b) Type
8 Current Transformers
a) Make
b) Type
9 L.T. Capacitors
a) Make
b) Type
9.16.5 Battery
1 Battery Capacity at 27° C at 10 hour rate
Initial
Rated
End of life
3 Rating
i) Input voltage
1. LT Power cable
2. Type
3. No. of cores
4. Size
9.16.9 Miscellaneous
1 Cable glands make and type
Make
Voltage grade
4 Outdoor Cabling:-
Cable route marker RCC block type prov. Yes/No
Cable protection covers RCC tiles prov. Yes/No
a) make
b) type
• Instruction manual for installation, operation and maintenance for battery and charger
9.17.5 Motors
Drawing and documents required
• GA drawing of the each motor showing dimensional details and terminal box details