Mini VRF
Mini VRF
–
Johnson Controls-Hitachi Air Conditioning
– –
–
SALES OFFICE
XXXXXXXXXXXXXX –
XXXXXXXXXXXXXX WARRANTY
–
SPARE PARTS
XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
– –
DISTRIBUTOR SOCIAL MEDIA
XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
The specifications of this catalog may change without prior notice to allow
Hitachi Cooling & Heating to incorporate the latest innovations for its customers. Find the products of Hitachi
The information contained in this catalog is merely informative.
C&H with the best service
Hitachi Cooling & Heating declines any responsibility in the broadest sense,
for damage, direct or indirect, arising from the use and / or interpretation of and conditions at your
the recommendations in this catalog. Hitachi Distributor
1806-C-HNRQ-1
— —
Design for tomorrow’s
and Hitachi
Spaces in our cities are under increasing
pressure. Urban areas demand landscape
preservation, and also require space
efficiency. SET FREE mini outdoor units
have a simple yet stylish design that does
not mar the urban appearance.
At the same time, since a powerful and
compact unit runs multiple indoor units,
it meets urban needs and the expectations
-
Learn more about our small
footprint outdoor units on
Page 07
— —
Live within a climate Redefining comfort
of your own making Comfort can be felt in a variety of ways,
from the temperature to quietness and
Air … To us it is something that is taken even the air flow itself. Our wide-ranging
line-up of indoor units can match various
too much for granted. comfort requirements.
So much so, that we can even forget it
WELCOME
-
exists. Nevertheless, air is so essential that Learn more about our
indoor units on
we could not go on living without it. Page 25
-
Learn more about our 01
control systems on
Page 57 02
-
INTRODUCING
SET FREE mini — —
Aesthetics Design flexibility
We can offer you a number of options Any local requirements and constraints
that help enhance the aesthetics of your can be met with a number of
—
Helping you form an — —
Higher performance Comfort
ideal living environment
We are committed to offering better Our units offer you a degree of comfort,
energy-saving results with our improved even in winter or in high humidity
We want to create a comfortable living outdoor units, indoor units and advanced environments.
environment where people can enjoy life control systems.
• Smart defrosting
to the full. SET FREE mini embodies
WELCOME
• Higher performance in both EER and COP
such a wish. A host of outdoor units, indoor • Low standby power consumption design
units and control devices matches the needs
of various living spaces. Which is not only — —
gratifying for the owners who use them, but Adaptability Easy installation
also brings diverse benefits to architects,
installers and other customers involved in Both the quality and capability of Overall cost and time reduction can be
adjustment to your environment are achieved thanks to our newly designed
space design. benefits of the HNRQ Series. outdoor units and original H-LINK system.
—
Easy servicing and maintenance
• H-LINK
03
• User-friendly service board for
easier test and diagnostic 04
07 OUTDOOR UNITS
09 LINE-UP OVERVIEW
—
10 AESTHETICS
11 DESIGN FLEXIBILITY
INDEX 13
14
HIGHER PERFORMANCE
COMFORT
15 ADAPTABILITY
17 EASY INSTALLATION
INDEX
45 FLOOR CONCEALED
47 FLOOR / CEILING CONVERTIBLE
49 CEILING SUSPENDED
51 WALL MOUNTED
53 TOTAL HEAT EXCHANGER
55 OPTIONAL PARTS FOR INDOOR UNITS
56 INTRODUCTION OF MOTION SENSOR KIT
57 CONTROL SYSTEMS
59 LINE-UP OVERVIEW
61 ADVANCED WIRED REMOTE CONTROLLER [PC-ARF1]
63 WIRELESS REMOTE CONTROLLER [HCRB10NEWQ]
WIRELESS REMOTE CONTROLLER [PC-LH3A]
64 RECEIVER KIT FOR WIRELESS REMOTE CONTROLLER
WIRED REMOTE CONTROLLER [HCWA10NEGQ]
65 CENTRAL STATION MINI FOR SMALL-SCALE BUILDINGS [PSC-A32MN]
CENTRAL STATION EZ FOR MEDIUM-SCALE BUILDINGS [PSC-A64GT]
66 CENTRAL STATION EX FOR LARGE-SCALE BUILDINGS [PSC-A128EX]
CENTRAL STATION FOR SMALL-MEDIUM-SCALE BUILDINGS [PSC-A64S] 05
06
—
OUTDOOR UNITS
07
08
— —
LINE-UP OVERVIEW AESTHETICS
OFFERING YOU THREE TYPES OF OUTDOOR UNITS LARGE CAPACITY OUTDOOR UNIT
(HP Class / Model Name / Cooling Capacity / Heating Capacity / Weight) SAVES INSTALLATION SPACE
Instead of the previous configuration of one indoor unit
connected to one outdoor unit, the new outdoor unit has
a capacity large enough to connect to multiple indoor
units, significantly reducing installation space. In addition,
this lets you preserve the aesthetic look of the building.
OUTDOOR UNITS
RAS-3.5HNBRKQ 10.0kW / 11.0kW / 75kg RAS-4.5HNBRKQ 12.0kW / 14.0kW / 114kg RAS-8.0HNBRMQ 22.4kW / 25.0kW / 154kg
5HP Class 9HP Class
RAS-5.0HNBRKQ 14.0kW / 16.0kW / 114kg RAS-9.0HNBRMQ 25.0kW / 27.5kW / 154kg
6HP Class 10HP Class
RAS-6.0HNBRKQ 16.0kW / 18.0kW / 118kg RAS-10HNBRMQ 28.1kW / 31.5kW / 172kg
6.5HP Class 11HP Class
RAS-6.5HNBRKQ 18.0kW / 20.0kW / 118kg RAS-11HNBRMQ 31.0kW / 33.9kW / 172kg
12HP Class
RAS-12HNBRMQ 33.5kW / 37.5kW / 172kg
SUMMARY TABLE
HP class HP 3 - 12
Capacity Nominal cooling kW 8.0 - 33.5
Nominal heating kW 9.0 - 37.5
Connectable indoor unit quantity unit 2 - 18
Combination capacity ratio between ODU and IDU (all range) % 50 - 130
Total liquid piping length m 100 - 180
Between outdoor unit and farthest indoor unit m 65 - 100
Maximum piping length
Between 1st branch multi kit and farthest indoor unit m 40
Between multi kit and each indoor unit m 15
Between outdoor unit and indoor units (ODU above IDU) m 30 / 50
Maximum level difference Between outdoor unit and indoor units (IDU above ODU) m 30 / 40
Between indoor units m 15
Cooling operation range * °C DB -5 to 52
Heating operation range * °C DB -20 to 24 09
* For more details, please consult your distributors or dealer, or, refer to technical manuals. 10
—
DESIGN FLEXIBILITY
3
1
4 2 B Better limit
C
in Height! B
A 1725mm C A 1650mm
OUTDOOR UNITS
ODU above IDU 30m 30m 30m 50m
Between outdoor unit and indoor units
Maximum level difference IDU above ODU 30m 30m 30m 40m
Between indoor units 15m 15m 15m 15m A
A
Each maximum length or level difference has several conditions, please refer to the technical documents in inquiry.
Better limit
B
in Depth! B
A 782mm A 390mm
HIGH EXTERNAL PRESSURE OF OUTDOOR UNIT WIDE INDOOR UNIT COMBINATION D A+B+C=2582mm
<More than 2.5m
D A+B+C=1190mm
<Less than 1.2m
D D
depth required> depth is enough!>
High external static pressure up to 30Pa is available in Because of the large-capacity outdoor unit, it is possible
order to avoid air short-circuit conditions. This ensures to install a whole range of indoor units in various rooms * 8HP Class
that the outdoor unit runs with a good ventilating using one outdoor unit. * Please refer to the installation manual for more details.
0Pa
30Pa
11
12
— —
HIGHER PERFORMANCE COMFORT
Heating COP
(W/W)
5.00 4.59 4.51 4.50 4.40 4.40
Automatically Learns Optimized Defrosting Operation
4.50 4.20 4.20 4.10 4.10
4.00 4.00
4.00 3.70 3.70
Defrosting Defrosting Defrosting Defrosting
OUTDOOR UNITS
3.50
3.00
HNRQ Series
2.50 Heating Heating Heating Heating
2.00 Defrosting Mode
1.50
1.00
0.50
0.00
3 3.5 4 4.5 5 6 6.5 7 8 9 10 11 12 (HP Class)
20W 5W 13
* 3 - 6.5HP Class
* Please refer to the technical catalog for more details. 14
—
ADAPTABILITY
Continuous
Operation
Working Range
-5
21 32
OUTDOOR UNITS
Indoor Air Inlet Temprature °C DB
Heating operation
HEATING
Continuous
Operation
Working Range
-15
Interval Operation Working Range
-20
15 27 15
3~3.5HP Class 75 kg
OUTDOOR UNITS
H-LINK
The PCB in the outdoor unit is equipped with two
H-LINK requires only two transmission wires connected 7-segment displays. The displays indicate various
to each outdoor unit for up to 64 refrigerant cycles, and operating modes, such as:
connecting wires for all indoor units and outdoor units.
• Outdoor air temperature
• Flexible installation options • Discharge temperature
• No polarity requirements • Evaporating temperature during heating operation
• Centralized Controller is enabled via indoor or outdoor unit • Condensing temperature
• Up to 160 indoor units and outdoor units can be connected • Discharge pressure
• Possible to have a cable length of up to 1,000m • Suction pressure
• Compressor run time
Centralized Controller to Outdoor Unit Centralized Controller to Indoor Unit
Therefore, quick and accurate diagnosing is available at
the site during the test run or normal operation.
Outdoor unit Outdoor unit Outdoor unit Outdoor unit
17
Centralized Centralized
Controller Controller H-LINK 18
—
EASY SERVICING AND MAINTENANCE
H-LINK
H-LINK can collect information on all indoor units from a
single outdoor unit. This substantially enhances service
and maintenance efficiency.
Outdoor unit Outdoor unit
OUTDOOR UNITS
USER-FRIENDLY SERVICE BOARD
FOR EASIER TESTING AND DIAGNOSTICS
User-friendly service board with dial code switch
and push button is designed for easier testing and
diagnostics.
The service board, which is located in front of the
outdoor unit, is easy to set.
19
20
— HP Class 3 3.5 4 4.5 5 6 6.5
OUTDOOR UNITS
Tubing Connection Method Flare Connection
Total Liquid
m 100 100 120 120 120 150 150
Pipe Length
Between ODU
m 65 65 70 70 70 85 85
and farthest IDU
Maximum
Piping Between 1st
Length Branch Multi Kit m 40 40 40 40 40 40 40
and Farthest IDU
Between Each
Multi Kit and m 15 15 15 15 15 15 15
Each IDU
Between ODU m 30 30 30 30 30 30 30
Maximum
Level and IDU m 30 30 30 30 30 30 30
Difference
Between IDUs m 15 15 15 15 15 15 15
NOTES:
1. The EER and COP are tested under the following working conditions, when the outdoor unit is connected to the special
combination of indoor units.
Working conditions for testing EER: Working conditions for testing COP:
• Indoor temperature: 27°C DB / 19°C WB • Indoor temperature: 20°C DB
• Outdoor temperature: 35°C DB • Outdoor temperature: 7°C DB / 6°C WB
• Pipe length: 10m • Pipe length: 10m
• Pipe lift: 0m • Pipe lift: 0m
2. Noise test conditions are specified below: Noise is tested 1.5m above ground level and 1m away from the surface of the
external service board on the outdoor unit. Noise parameters are tested in a semi-anechoic chamber.
3. Please consult your local distributor for indoor unit combination limitations.
Model RAS-[3.0~6.5]HNBRKQ
HP Class 3 - 6.5 21
Applicable
Outdoor Unit Cooling kW 8.0 - 18.0 Gas pipe Liquid pipe 22
— HP Class 7 8 9 10 11 12
OUTDOOR UNITS
Total Liquid
m 180 180 180 180 180 180
Pipe Length
Between ODU
m 100 100 100 100 100 100
and farthest IDU
Maximum
Piping Between 1st
Length Branch Multi Kit m 40 40 40 40 40 40
and Farthest IDU
Between Each
Multi Kit and m 15 15 15 15 15 15
Each IDU
Maximum Between ODU m 50 50 50 50 50 50
Level and IDU m 40 40 40 40 40 40
Difference Between IDUs m 15 15 15 15 15 15
* Indicates that there are pipe adapters in the outdoor unit, which are used to adjust the gas pipe between the outdoor unit and
the first branch. Thus the φ19.05 diameter pipe is converted to φ22.2 diameter pipe in the model.
** Indicates that there is a pipe adapter in the model, which is used to adjust the gas pipe length between the outdoor unit and
the first branch. Thus the φ19.05 diameter pipe is converted to a φ25.4 diameter pipe.
NOTES:
1. The EER and COP are tested under the following working conditions, when the outdoor unit is connected to the special
combination of indoor units.
Working conditions for testing EER: Working conditions for testing COP:
• Indoor temperature: 27°C DB / 19°C WB • Indoor temperature: 20°C DB
• Outdoor temperature: 35°C DB • Outdoor temperature: 7°C DB / 6°C WB
• Pipe length: 10m • Pipe length: 10m
• Pipe lift: 0m • Pipe lift: 0m
2. Noise test conditions are specified below: Noise is tested 1.5m above ground level and 1m away from the surface of the
external service board on the outdoor unit. Noise parameters are tested in a semi-anechoic chamber.
3. Please consult your local distributor for indoor unit combination limitations.
Model RAS-[7.0~12]HNBRKQ
HP Class 7 - 12 23
Applicable
Outdoor Unit Cooling kW 20.0 - 33.5 Gas pipe Liquid pipe 24
-
INDOOR UNITS
& VENTILATION
25
26
—
LINE-UP OVERVIEW
kW (Cooling) 1.6 1.8 2.2 2.5 2.8 3.2 3.6 4.0 4.3 4.5 5.0 5.6 6.3 7.1 8.0 8.4 9.0 10.0 11.2 12.5 14.0 14.2 16.0 22.4 28.0
Ceiling 4-way
Cassette cassette
Medium ESP
High ESP type Medium ESP type Low ESP type Slim type Compact type
* High ESP (90/120Pa for 3.0- * 2 steps of medium ESP * Low ESP (30Pa for 0.8-2.5 * Ideal for narrow ceiling void * Ideal for installation over
High ESP
Concealed Floor
& Exposed concealed CONCEALED & EXPOSED
Floor /
Ceiling
convertible
Ceiling
suspended Floor concealed Floor/Ceiling convertible Ceiling suspended Wall mounted
* Visual aesthetics are * Fully floor-mounted * Ideal for a higher ceiling * Simple installation
improved by hiding the unit or ceiling suspended installation location (up to procedure
away even when there is no installation convertible 5.6m in cooling mode) * Flexible discreet design
ceiling void * Easy installation * Better energy-saving with suitable to any interior
Wall * Little installation space * Fresh air-intake design optional motion sensor
mounted required thanks to depth of * Optional drain pump * Quiet operation level as
only 202mm available low as 28dB (A)
* Height of up to just 620mm, 27
suitable for installation
* 22.4 and 28.0kW (cooling capacity) Ducted units are available with one-to-one connection only. beneath windows 28
— Model RCI- RCI- RCI- RCI- RCI- RCI- RCI- RCI-
4-WAY CASSETTE
1.0FSKDNQ 1.5FSKDNQ 2.0FSKDNQ 2.5FSKDNQ 3.0FSKDNQ 4.0FSKDNQ 5.0FSKDNQ 6.0FSKDNQ
Indoor Unit Power Supply AC 1Φ , 220-240V/50Hz, 220V/60Hz
Nominal Cooling kW 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Capacity Heating kW 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Sound
Pressure Level (Hi2/Hi/Me/Lo) dB (A) 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37
Outer
DIMENSIONS Dimensions (H×W×D) mm 248×840×840 248×840×840 248×840×840 248×840×840 298×840×840 298×840×840 298×840×840 298×840×840
Net Weight kg 20 21 21 22 26 26 26 26
RCI-1.0 FSKDNQ 20kg 840mm 840mm Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
RCI-1.5~2.0 FSKDNQ 21kg Indoor Fan (Hi2/Hi/Me/Lo) m3/min 15/13/11/9 21/17/14/11 22/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22
248mm Air Flow Rate
RCI-2.5 FSKDNQ 22kg
Motor W 57 57 57 57 57 127 127 127
Decoration panel 6.5kg Connections Flare-nut Connection (with flare Nuts)
950mm 950mm
Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52
Piping
RCI-3.0~6.0 FSKDNQ 26kg Approximate Packing Volume m3 0.21 0.21 0.21 0.21 0.25 0.25 0.25 0.25
298mm
Decoration panel 6.5kg
NOTES:
Adaptability Design Flexibility 1. The cooling and heating capacities above show maximum capacities when outdoor
and indoor temperatures are as follows.
Cooling Operation Conditions Heating Operation Conditions
1) Wide detection area of motion sensor (PS-MSK2) 1) Suitable for high ceiling space Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Detection area
2) Control air flow with individual four-way louvers 2) Standard drain pump with 850 mm lift
Achieves more comfortable air conditioning as
required by each zone.
Horizontal
4-WAY CASSETTE COMPACT Indoor Unit Power Supply AC 1Φ , 230V 50Hz, 220-240V 50Hz, 220V 60Hz
NOTES:
1. The cooling and heating capacities above show maximum capacities when outdoor
FEATURES AND BENEFITS and indoor temperatures are as follows.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
Adaptability Design Flexibility 19.0oC WB (66.2oF WB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB)
Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
1) Top-class silent operation 1) Compact 2. The sound pressure level is based on following conditions:
Drain
30mm 850
thickness mm
(Heating
ng) (C
Cooling)
Co
Up to Up to
U
Fully opened louvers 3.5
5m 4.6
4
4. m
down
ow
wn down
do
don’t exceed the Simple design
surface
31
32
— Model RCD- RCD- RCD- RCD- RCD- RCD- RCD- RCD- RCD-
2-WAY CASSETTE
0.8FSN3 1.0FSN3 1.5FSN3 2.0FSN3 2.5FSN3 3.0FSN3 4.0FSN3 5.0FSN3 6.0FSN3
Indoor Unit Power Supply AC 1Φ , 220-240V/50Hz, 220V/60Hz
Nominal Cooling kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Capacity Heating kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Sound
Pressure Level (Hi2/Hi/Me/Lo) dB (A) 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39
Outer
DIMENSIONS Dimensions (H×W×D) mm 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×860×630 298×1,420×630 298×1,420×630 298×1,420×630
Net Weight kg 23 23 25 25 25 25 39 39 39
RCD-0.8~1.0 FSN3 23kg 630mm Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
860mm
RCD-1.5~2.0 FSN3 25kg Indoor Fan (Hi2/Hi/Me/Lo) m3/min 10/9/7.5/6.5 11/9.5/8.5/7 15/13/11.5/10 16.5/14.5/12.5/10.5 18.5/16.5/14.5/12.5 21/18.5/16/12.5 30/26.5/23/20 35/31/27/21 37/32.5/28.5/24
Air Flow Rate
298mm
RCD-2.5~3.0 FSN3 25kg Motor W 57 57 57 57 57 57 57 x 2 57 x 2 57 x 2
P-AP90DNA 7.5kg 1,100mm Connections Flare-nut Connection (with Flare Nuts)
710mm
Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52
Piping
Height
3.1m (Heating)
n )
ng (C
Cooling)
Co
oo
Up to
o Up
Up to
3.5
5 m 4.6 m
down
ow
wn dow
own
Above
b fl
floor
level 0.8m
Diameter 8 5m
8.5 * Air flow rate: Hi2
* 2.0-6.0 FSN3
2) Control air flow with individual louvers 2) Easy fine-tune for installment height
Suitable environment can be achieved for each person.
Easier
height
Adjustment
Corner
pocket 33
34
— Model RCS-0.8FSN RCS-1.0FSN RCS-1.5FSN RCS-2.0FSN RCS-2.5FSN RCS-3.0FSN
DIMENSIONS Outer
Dimensions (H×W×D) mm 235×900×720 235×900×720 235×900×720 235×900×720 235×1,210×720 235×1,210×720
Net Weight kg 25 25 26 26 33 33
RCS-0.8~1.0 FSN 25kg
900mm 720mm Refrigerant R410A R410A R410A R410A R410A R410A
RCS-1.5~2.0 FSN 26kg
235mm Indoor Fan (Hi2/Hi/Me/Lo) m /min
3
8.5/7.5/6.5/6 9.5/8.5/7.5/6.5 13/11.5/10/8.5 14.5/13/11/9.5 18.5/16.5/14.5/12.5 20/17.5/15.5/13
P-AP36CNA 4.5kg Air Flow Rate
800mm 1,100mm Motor W 50 50 50 50 80 80
P-AP56CNA 4.5kg
Connections Flare-nut Connection (with Flare Nuts)
Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 9.52 Φ 9.52
Adaptable Panel Model P-AP36CNA (for RCS- [0.8-1.0]FSN) P-AP56CNA (for RCS- [1.5-2.0]FSN) P-AP80CNA (for RCS- [2.5-3.0]FSN)
7m
Clipped ceiling (two-way) type
Non d
detecting
i area Provides increased comfort through two-
direction air flow by utilizing the advantages of
installation on a clipped ceiling.
Indoor 7m Room temperature distribution can be improved
unit
by both forward air flow and downward airflow.
7m
192mm
Model RPI-(3.0~10.0)FSNQH
(FSNQ)
RPI-(0.8~10.0)FSNQH
(FSN3Q) RPI-(0.8~6.0)FSNQL RPIZ-(0.8~1.5)FSNQS/P RPIZ-(0.8~2.5)FSN1Q/P 2.2-4.3kW
Compact
Cooling kW 8.4 – 28.0 2.2 – 28.0 2.2 – 16.0 2.2 – 4.3 2.2 – 7.1 Over the closet
Capacity
Heating kW 9.6 – 31.5 2.8 – 31.5 2.8 – 18.0 2.8 – 4.9 2.8 – 8.5
Height mm 350 – 470 270 – 470 250 192 192
Dimensions Width mm 975 – 1,250 725 – 1,250 700 700 900 – 1,170
Depth mm 800 – 1,120 720 – 1,120 800 602 447
447mm
Net Weight kg 46 – 104 26 – 104 26 – 27 21 20 – 26 1,170mm
192mm
• High ESP
90/120Pa for 3.0-6.0 models, 180Pa for 8.0-10.0 models.
• 2 steps of medium ESP
50/80Pa for 0.8-2.5 models, 100Pa for 8.0-10.0 models.
The indoor fan motor has three speeds that can be adjusted
to allow for pressure loss in the duct, thus providing a more
efficient air flow.
37
* 22.4 and 28.0kW (cooling capacity) Ducted units are available with one-to-one connection only. 38
High ESP (External Static Pressure) Type Slim Type
Model RPI-3.0FSNQH RPI-3.3FSNQH RPI-4.0FSNQH RPI-5.0FSNQH RPI-6.0FSNQH RPI-8.0FSNQ RPI-10.0FSNQ Model RPIZ-0.8FSNQS/P RPIZ-1.0FSNQS/P RPIZ-1.3FSNQS/P RPIZ-1.5FSNQS/P
Indoor Unit Power Supply AC 1 Φ , 220-240V/50Hz AC 3 Φ , 380-415V/50Hz Indoor Unit Power Supply AC 1Φ , 220-240V 50Hz, 220V 60Hz
Nominal Cooling kW 8.4 9.0 11.2 14.2 16.0 22.4 28.0 Nominal Cooling kW 2.2 2.8 3.6 4.3
Capacity Heating kW 9.6 10.0 13.0 16.3 18.0 25.0 31.5 Capacity Heating kW 2.8 3.3 4.2 4.9
Sound Sound
Pressure Level (Hi/Me/Lo) dB (A) 42/39/35 42/39/35 43/40/36 44/41/37 45/41/37 50 52 Pressure Level (Hi/Me/Lo) dB (A) 28/25/22 28/25/22 32/30/28 32/30/28
Outer Outer
Dimensions (H×W×D) mm 350×975×800 350×975×800 350×975×800 350×1,375×800 350×1,375×800 470×1,060×1,120 470×1,250×1,120 Dimensions (H×W×D) mm 192×700×602 192×700×602 192×700×602 192×700×602
Net Weight kg 46 46 46 58 58 96 104 Net Weight kg 21 21 21 21
Refrigerant R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A
Indoor Fan (Hi/Me/Lo) m3/min 25/21/17 25/21/17 27/23/19 37/31/25 38/35/29 58 72 Indoor Fan (Hi/Me/Lo) m3/min 8/7/6 8/7/6 10/8/7 10/8/7
Air Flow Rate Air Flow Rate
External Static Pressure *3) Pa 120 (90/120) 120 (90/120) 120 (90/120) 120 (90/120) 120 (90/120) 180 180 External Standard
Static Pa 10 (10/30) 10 (10/30) 10 (10/30) 10 (10/30)
Connections Flare-nut Connection (with Flare Nuts) Brazing Pressure (min/max)
Refrigerant Liquid Line mm Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Motor W 15 15 25 25
Piping Connections Flare-nut Connection (with Flare Nuts)
Diameter Gas Line mm Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 19.05 Φ 22.23
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35
NOTES:
1. The cooling and heating capacities above show maximum capacities when outdoor and indoor temperatures are as follows.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
19.0oC WB (66.2oF WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions:
1.5 meters beneath the unit. With discharge duct (2.0 meters) and return duct (1.0 meters). Voltage of the power supply for the
indoor fan motor is 220V. The above data was measured in an anechoic chamber. Therefore, reflected sound should be taken
into consideration in the field.
3. The data for external static pressure *3) indicates "Standard Pressure Setting
(High Pressure Setting 1 / High Pressure Setting 2)" values when a filter is not used. 39
The sound pressure level is based on the Standard Pressure Setting.
* 22.4 and 28.0kW (cooling capacity) Ducted units are available with one-to-one connection only. 40
— High ESP (External Static Pressure) Type
DUCTED HNG SERIES (220V) Model RPIH- RPIH- RPIH- RPIH- RPIH- RPIH- RPIH- RPIH- RPIH-
(Without drain-pump) 0.8HNGUAQ 1.0HNGUAQ 1.3HNGUAQ 1.5HNGUAQ 1.6HNGUAQ 1.8HNGUAQ 2.0HNGUAQ 2.3HNGUAQ 2.5HNGUAQ
Nominal Cooling kW 2.2 2.8 3.6 4.0 4.5 5.0 5.6 6.3 7.1
Capacity Heating kW 2.5 3.2 4.0 4.5 5.0 5.6 6.3 7.1 8.0
DUCTED HNG SERIES
Sound
Pressure Level (Hi/Me/Lo) dB (A) 34/30/26 34/30/26 38/35/31 38/35/31 38/35/31 37/35/30 37/35/30 39/35/30 39/35/30
The Ducted HNG Series is ideal for small rooms where
Outer
appearance is important, such as bedrooms and Dimensions (H×W×D) mm 270×725×720 270×725×720 270×725×720 270×725×720 270×725×720 270×975×720 270×975×720 270×975×720 270×975×720
galleries. The Series integrates flexibly with the room, Net Weight kg 23 23 25 25 25 30 30 31 31
steadily maintaining room temperature while in no way Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
obtruding on its surroundings. Indoor Fan (Hi/Me/Lo) m /min
3
9/7/6 9/7/6 12/10/8.5 12/10/8.5 12/10/8.5 15/13/10 15/13/10 19/14/10 19/14/10
Air Flow Rate
FEATURES AND BENEFITS OF HIGH ESP & MEDIUM ESP TYPES Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A
Indoor Fan (Hi/Me/Lo) m3/min 28/24/19.5 28/24/19.5 28/24/19.5 28/24/19.5 35.5/29/24 35.5/29/24 39/31/24 58 72
Air Flow Rate
Adjustable Fan Speed External Static Standard Pa 120 (90/120) 120 (90/120) 120 (90/120) 120 (90/120) 120 (90/120) 120 (90/120) 120 (90/120) 220 220
Pressure (min/max)
You can adjust the indoor fan motor, up to three levels, Connections Flare-nut Connection (with Flare Nuts) Brazing
to reduce the pressure in the duct, thus provides more Refrigerant Liquid Line mm Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52
Piping
efficient air flow. Diameter Gas Line mm Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 19.05 Φ 22.23
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Space-saving Design Approximate Packing Volume m3 0.4 0.4 0.4 0.4 0.49 0.49 0.49 0.9 1.06
Nominal Cooling kW 2.2 2.8 3.6 4.0 4.5 5.0 5.6 6.3 Nominal Cooling kW 1.8 2.2 2.5 2.8 3.2 3.6
Capacity Heating kW 2.5 3.2 4.0 4.5 5.0 5.6 6.3 7.1 Capacity Heating kW 2.2 2.5 2.8 3.2 3.6 4.0
Sound Sound
Pressure Level (Hi/Me/Lo) dB (A) 29.5/27/24.5 29.5/27/24.5 35/32/28 35/32/28 35/32/28 34/31/29.5 34/31/29.5 38/32/27 Pressure Level (Hi/Me/Lo) dB (A) 28/23/20 28/23/20 28/23/20 33/26/21 33/26/21 33/26/21
Outer Outer
(H×W×D) mm 270×725×720 270×725×720 270×725×720 270×725×720 270×725×720 270×975×720 270×975×720 270×975×720 (H×W×D) mm 192×700×450 192×700×450 192×700×450 192×700×450 192×700×450 192×700×450
Dimensions Dimensions
Net Weight kg 23 23 25 25 25 30 30 31 Net Weight kg 16 16 16 17 17 17
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A Refrigerant R410A R410A R410A R410A R410A R410A
Indoor Fan (Hi/Me/Lo) Indoor Fan (Hi/Me/Lo)
m /min
3
9/7/6 9/7/6 12/10/8.5 12/10/8.5 12/10/8.5 15/13/10 15/13/10 19/14/10 m /min
3
7.5/6/4.5 7.5/6/4.5 7.5/6/4.5 9/6/5 9/6/5 9/6/5
Air Flow Rate Air Flow Rate
Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 9.52 Connections Flare-nut Connection (with Flare Nuts)
Piping
Diameter Gas Line mm Φ 12.70 Φ 12.70 Φ 12.70 Φ 12.70 Φ 12.70 Φ 15.88 Φ 15.88 Φ 15.88 Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35
Piping
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Diameter Gas Line mm Φ 12.70 Φ 12.70 Φ 12.70 Φ 12.70 Φ 12.70 Φ 12.70
Approximate Packing Volume m3 0.22 0.22 0.22 0.22 0.22 0.28 0.28 0.28 Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
Approximate Packing Volume m 3
0.14 0.14 0.14 0.14 0.14 0.14
Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A Net Weight kg 21 21 25 25 25 25
Indoor Fan (Hi/Me/Lo) Refrigerant R410A R410A R410A R410A R410A R410A
m3/min 19/14/10 28/24/19.5 28/24/19.5 28/24/19.5 28/24/19.5 35.5/29/24 35.5/29/24 39/31/24
Air Flow Rate
Indoor Fan (Hi/Me/Lo) m3/min 10/8/6 10/8/6 14.5/12.5/8 14.5/12.5/8 16.5/14.5/10 16.5/14.5/10
External Static Pressure Pa 30 60 60 60 60 60 60 60 Air Flow Rate
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25 Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 9.52 Φ 9.52
Piping
Approximate Packing Volume m3 0.28 0.4 0.4 0.4 0.4 0.49 0.49 0.49 Diameter Gas Line mm Φ 12.70 Φ 12.70 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25
NOTES:
1. The cooling and heating capacities above show maximum capacities when outdoor and indoor temperatures are as follows. Approximate Packing Volume m 3
0.18 0.18 0.22 0.22 0.22 0.22
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB) NOTES:
19.0oC WB (66.2oF WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB) 1. The cooling and heating capacities above show maximum capacities when outdoor and indoor temperatures are as follows.
Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43oF WB)
Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
2. The sound pressure level is based on following conditions: 19.0oC WB (66.2oF WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
1.5 meters beneath the unit. Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43oF WB)
With discharge duct (2.0 meters) and return duct (1.0 meters). Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
Voltage of the power supply for the indoor fan motor is 220V.
The above data was measured in a semi-anechoic chamber under the working conditions 2. The sound pressure level is based on following conditions:
that are used to test the nominal cooling capacity and nominal heating capacity. 1.5 meters beneath the unit.
With discharge duct (2.0 meters) and return duct (1.0 meters).
Voltage of the power supply for the indoor fan motor is 220V.
The above data was measured in a semi-anechoic chamber under the working conditions
that are used to test the nominal cooling capacity and nominal heating capacity.
43
44
— Model RPFI-1.0FSNQ RPFI-1.5FSNQ RPFI-2.0FSNQ RPFI-2.5FSNQ
Sound
Pressure Level (Hi/Me/Lo) dB (A) 37/34/31 40/38/35 42/38/36 45/43/40
DIMENSIONS Outer (H×W×D) mm 620×900×202 620×900×202 620×1,170×202 620×1,170×202
Dimensions
RPFI-1.0FSNQ 25kg Net Weight kg 25 26 34 34
620mm
RPFI-1.5FSNQ 26kg
Refrigerant R410A R410A R410A R410A
202mm Indoor Fan (Hi/Me/Lo)
900mm m3/min 8.5/7/6 12/8/7 16/12.5/10.5 16/14/11
Air Flow Rate
NOTES:
1. The cooling and heating capacities above show maximum capacities when outdoor
and indoor temperatures are as follows.
Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
19.0oC WB (66.2oF WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43oF WB)
FEATURES AND BENEFITS Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
2.The sound pressure level is based on following conditions:
• Blends unobtrusively with any interior décor: 1.5 meters beneath the unit.
With discharge duct (2.0 meters) and return duct (1.0 meters).
only the suction and discharge grilles are visible. Voltage of the power supply for the indoor fan motor is 220V.
The above data was measured in an anechoic chamber. Therefore,
reflected sound should be taken into consideration in the field.
45
46
— Model RPFC-1.8FSNQ RPFC-2.0FSNQ RPFC-2.3FSNQ RPFC-2.5FSNQ RPFC-3.0FSNQ RPFC-3.3FSNQ RPFC-4.0FSNQ RPFC-5.0FSNQ
FLOOR / CEILING CONVERTIBLE Indoor Unit Power Supply AC 1Φ , 220-240V 50Hz, 220V 60Hz
Ceiling Mode dB (A) 39/35/30 39/35/30 45/41/37 45/41/37 43/39/34 45/40/36 51/46/40 50/46/42
Sound
DIMENSIONS Pressure Level
Floor Mode dB (A) 43/38/35 43/38/35 48/44/40 48/44/40 46/41/37 48/43/39 54/49/43 55/50/46
680mm Outer
RPFC-1.8~2.0FSNQ 31kg (H×W×D) mm 230×990×680 230×990×680 230×990×680 230×990×680 230×1,285×680 230×1,285×680 230×1,285×680 230×1,580×680
Dimensions
RPFC-2.3~2.5FSNQ 32kg 230mm Net Weight kg 31 31 32 32 39 40 41 47
990mm Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A
RPFC-3.0FSNQ 39kg Indoor Fan (Hi/Me/Lo) m3/h 780/660/540 780/660/540 966/840/678 966/840/678 1092/912/732 1164/978/798 1488/1230/978 1980/1680/1380
680mm Air Flow Rate
RPFC-3.3FSNQ 40kg
Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52 Φ 9.52
680mm Piping
RPFC-5.0FSNQ 47kg Diameter Gas Line mm Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88 Φ 15.88
230mm
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
1,580mm
Approximate Packing Volume m3 0.31 0.31 0.31 0.31 0.40 0.40 0.40 0.48
NOTES:
1. The cooling and heating capacities above show maximum capacities when outdoor
and indoor temperatures are as follows.
FEATURES AND BENEFITS Cooling Operation Conditions Heating Operation Conditions
Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
19.0oC WB (66.2oF WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43oF WB)
Adapts to both floor and ceiling New air-intake design Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
2.The sound pressure level is based on following conditions:
1.5 meters beneath the unit.
Ceiling Type
⟦FLOOR USE⟧
• Smaller footprint: Only 230mm in depth.
• Suitable for installation beneath a window
thanks to the 680mm height.
Floor Type
47
48
— Model RPC-1.5FSN3 RPC-2.0FSN3 RPC-2.5FSN3 RPC-3.0FSN3 RPC-4.0FSN3 RPC-5.0FSN3 RPC-6.0FSN3
Drain
600
mm
7m
Ceiling height
2.7m
(Heating) (Cooling)
Up to Up to
1.8m 7m
4.3 m 5.6
5 m
down down
2) Auto louver
* Air flow rate: Hi2
Auto louver * 4.0-6.0 FSN3
Ȃ Down Horizontal
3) Quiet operation
Newly designed fan inlet and fan has achieved lower
sound pressure level.
50
— Type Expansion Valve Built-in Type
WALL MOUNTED Model RPK-0.8FSNQS RPK-1.0FSNQS RPK-1.3FSNQS RPK-1.5FSNQS RPK-1.8FSNQS RPK-2.0FSNQS RPK-2.3FSNQS
Indoor Unit Power Supply AC 1Φ , 220-240V/50Hz
Nominal Cooling kW 2.2 2.8 3.6 4.0 5.0 5.6 6.3
Capacity Heating kW 2.5 3.3 4.0 4.5 5.6 6.3 7.1
Sound
Pressure Level (Hi/Me/Lo) dB (A) 35/32/31/29 39/35/32/30 39/35/32/30 46/40/36/33 39/35/32/30 46/40/36/33 42/40/38/33
Color White
DIMENSIONS 780mm 220mm Outer
Dimensions (H×W×D) mm 280×780×220 280×780×220 280×780×220 280×780×220 290×1,050×220 290×1,050×220 290×1,050×220
Net Weight kg 10 10 10 10 12.5 12.5 12.5
280mm
RPK-0.8-1.5FSNQS 10kg Refrigerant R410A R410A R410A R410A R410A R410A R410A
Indoor Fan (Hi/Me/Lo) m3/min 8.5/7.5/6.5 8.5/7.5/6.5 9.2/7.5/6.7 10/8.5/7.5 12/10.3/8.7 12/10.3/8.7 13.7/12/10.3
Air Flow Rate
220mm Connections Flare-nut Connection (with Flare Nuts)
1,050mm
Refrigerant Liquid Line mm Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35 Φ 6.35
Piping
Diameter Gas Line mm Φ 12.7 Φ 12.7 Φ 12.7 Φ 12.7 Φ 12.7 Φ 12.7 Φ 12.7
RPK-1.8-2.3FSNQS 12.5kg 290mm
Condensate Drain VP16 VP16 VP16 VP16 VP16 VP16 VP16
1,150mm 245mm
Type Expansion Valve Built-in Type
RPK-2.5-4.0FSN3M 18kg
333mm Model RPK-2.5FSNSM3 RPK-3.0FSNSM3 RPK-4.0FSNSM3
Indoor Unit Power Supply AC 1Φ , 220-240V/50Hz, 220V/60Hz
Nominal Cooling kW 7.1 8.0 11.2
Capacity Heating kW 8.5 9.0 12.5
Sound (Hi2/Hi/Me/Lo) dB (A) 49/43/40/36 49/43/40/36 51/49/46/41
Pressure Level
Color White
Outer
Dimensions (H×W×D) mm 300×1,150×245 300×1,150×245 300×1,150×245
FEATURES AND BENEFITS Net Weight kg 18 18 18
Refrigerant R410A R410A R410A
Simple installation procedure Indoor Fan
Air Flow Rate (Hi2/Hi/Me/Lo) m3/min 19/17/14/12 19/17/14/12 22/19/17/15
Connections Flare-nut Connection (with Flare Nuts)
Refrigerant piping can be connected from the rear, Refrigerant Liquid Line mm Φ 9.52 Φ 9.52 Φ 9.52
flexibility for piping and selection of installation sites. Condensate Drain VP16 VP16 VP16
Approximate Packing Volume m3 0.14 0.14 0.14
Accessory Included Wall Mounting Bracket
NOTES:
Flexible design suitable for any décor 1. The cooling and heating capacities above show maximum capacities when outdoor
and indoor temperatures are as follows.
Cooling Operation Conditions Heating Operation Conditions
With smooth flat covers, the units match most modern Indoor Air Inlet Temperature: 27oC DB (80oF DB) Indoor Air Inlet Temperature: 20oC DB (68oF DB)
interiors. Their compact size enables them to blend in, 19.0oC WB (66.2oF WB) Outdoor Air Inlet Temperature: 7oC DB (45oF DB)
Outdoor Air Inlet Temperature: 35oC DB (95oF DB) 6oC WB (43oF WB)
even in small spaces. Piping Length: 7.5 Meters Piping Lift: 0 Meter Piping Length: 7.5 Meters Piping Lift: 0 Meter
2.The sound pressure level is based on following conditions:
1.5 meters beneath the unit.
With discharge duct (2.0 meters) and return duct (1.0 meters).
Voltage of the power supply for the indoor fan motor is 220V.
Easy maintenance The above data was measured in an anechoic chamber. Therefore,
reflected sound should be taken into consideration in the field.
Front flat panel keeps the unit from dust and facilitates
maintenance work. The front grille hinges open easily—no
tools are needed to gain quick access to the filter. The filter
can be removed and cleaned as required.
51
52
—
Model
TOTAL HEAT EXCHANGER
KPI-20H-A-GQ KPI-30H-A-GQ KPI-40H-A-GQ KPI-50H-A-GQ KPI-65H-A-GQ KPI-80H-A-GQ KPI-100H-A-GQ KPI-125H-A-GQ
Sound
Pressure (Hi/Me/Lo) dB (A) 32/30/25 36/34/28 39/37/30 40/38/31 40/38/35 40/38/34 43/42/34 42/40/37
Level
Net Weight kg 38 40 46 52 61 69 69 95
Air Flow Rate (Hi/Me/Lo) m3/h 200/200/150 300/300/210 400/400/230 500/500/400 650/650/550 800/800/650 1000/1000/700 1250/1250/800
External
Static (Hi/Me/Lo) Pa 100/70/40 120/90/50 120/90/50 120/90/50 130/100/90 130/100/90 165/120/60 100/50/30
Pressure
FEATURES AND BENEFITS
Power Input (Hi/Me/Lo) W 120/110/75 165/155/120 210/200/130 330/310/230 2*(188/173/142) 2*(207/188/165) 2*(250/228/205) 2*(308/266/237)
Summer % 63 63 63 63 63 63
Temperature
Efficiency
Winter % 68 72 75 75 73 73
Summer % 57 57 55 56 55 53
Enthalpy
Efficiency
Winter % 68 68 72 72 63 61
Air Flow Rate m3/h 1500 2000 2500 3000 4000 5000
Connection Duct Diameter mm 400*320 + 400*320 400*320 + 400*320 500*350 + 500*350 500*350 + 500*350 400*320 + 590*320 500*350 + 700*320
OTHERS
Ceiling suspended Wall mounted Motion Sensor Kit Indoor Unit Motion Sensor Kit Indoor Unit
Receiver Kit PC-ALHP1 Standard PC-RLH11 PS-MSK2 4-way cassette SOR-NES 1-way cassette
Receiver Kit
Motion Sensor SOR-NEP Optional PC-ALHZ1
4.0 (kW) DUPI-63K1 2.2-6.3 (kW) MSF-NP63A1 SOR-NEC 4-way cassette compact SOR-NEP Ceiling suspended
Strainer Kit
Optional Drain Pump 5.6 (kW) DUPI-71K1 7.1-11.2 (kW) MSF-NP112A1
7.1-16.0 (kW) DUPI-160K1 55
SOR-NED 2-way cassette
* ( kW = Cooling capacity) 56
—
CONTROL SYSTEMS
57
58
—
LINE-UP OVERVIEW
CONTROL SYSTEMS
Alarm history display - - Operation Unit By block
By indoor unit - - -
ODU noise reduction schedule - - -
Main 5 functions (*5)
Schedule
Main-sub control setting - -
& Management Individual controller lock △ (*3)
Operation lock - -
Control Function Filter sign reset
Adjusting date/timer setting - - - Outdoor unit capacity control △ (*4) - -
Weekly -
Annual/Summer/Winter shedule - - -
(*1) One external adapter can control [128 remote controller groups / 128 groups / 32 blocks], and Central Station EX can connect up to 15 adapters.
(*2) No restriction on the number of H-LINK. (*3) Individual Function Control in Each Remote Controller is not applicable.
(*4) Applicable by Schedule function or External Signal input. (*5) Main 5 functions mean 1) Run/Stop 2) Operation mode 3) Temperature setting 4) Fan speed 5) Louver
control. 59
60
—
ADVANCED WIRED REMOTE CONTROLLER [PC-ARF1]
Room Name Indicator Filter Sign Indicator FLTR SPECIFICATIONS SIMPLE OPERATION
Swing Louver Indicator
Operation Lock Indicator
Fan Speed Indicator
Ventilation Indicator
Schedule Timer Indicator Outer Dimensions (H×W×D) mm 120.0×120.0×17.9 Directional key Power-saving button
Net Weight g 200
4 main items [Mode] [Speed] [Louver] [Temperature] Easy access to any of the
power-saving functions,
Operation Mode
including support
Setting guidance.
CONTROL SYSTEMS
Improved main-sub RCS control Thermometer function
Up to 16 IDUs
Transmitter
SPECIFICATIONS Model PC-ALH3 PC-ALHC1 PC-ALHD1 PC-ALHS1 PC-ALHP1 Standard: PC-RLH11
(Optioned: PC-ALHZ1)
*Centralized controller (Central Station EX/ EZ/ mini) cannot be operated when you use a standard receiver kit (PC-RLH11) exquipped with wireless remote controller (PC-LH3A).
CONTROL SYSTEMS
NOTES:
H-LINK When you use a standard receiver kit (PC-RLH11) equipped with wireless remote controller (PC-LH3A).
1) Hi2 setting for air-flow rate is not available even if the connected indoor unit has Hi2 air flow rate setting.
Remote Control Cable
2) It is not possible to set up "remote control switch operation prohibited by each function setting" from central station (mini/EZ/EX).
3) It is not possible to set up "remote control switch temperature setting range limitation function" from central station (mini/EZ/EX).
— —
WIRELESS REMOTE CONTROLLER [PC-LH3A] WIRED REMOTE CONTROLLER [HCWA10NEGQ]
Residence
SPECIFICATIONS Temperature display SPECIFICATIONS
Transmitter Room temperature
Outer Dimensions (H×W×D) mm 125.0×56.0×16.4 Outer Dimensions (H×W×D) mm 88.0×88.0×15.5
CONTROL SYSTEMS
(*1) This is the air intake temperature on representative outdoor unit.
(*2) Some indoor units may not fully support all functions.
80 CAPACITY CAPACITY
25 55
Remote Controller Group 64 RC Group 64
Group 64 Group 64
Block 4 Patterns Block 4 Patterns
Indoor Unit 160 Indoor Unit 160
Outdoor Unit 64 Outdoor Unit 64
Buidling Scale Small - Medium 120mm
170mm
SPECIFICATIONS SPECIFICATIONS
Rated Power Supply 1-, AC 100-240V, 50/60Hz Outer Dimensions (H×W×D) 120.0×120.0×70.5mm
Electrical PowerConsumption 30W (Max.) Net Weight 300g
Communication Unit Units of Adopting for H-LINK
Communication Line Non-polar 2-wire
Lateral View Communication Speed 9,600bps FUNCTIONS
250mm (mm) Wiring Length 1,000m (Total Length) • Run/Stop/Abnormality • Setting Temperature
120mm
Display 8.5-inch Wide Color LCD (Full Dot) • RCS Operation Prohibited Setting
Display Control Touch Panel Monitor Function • Accumulated Operating Time
Easy control with 8.5-inch color touch panel. Its If your site has a dedicated building manager, the Central • Operation Mode • Setting Fan Speed
• Setting Louver • Filter Sign • Alarm Code
detailed control features, such as Weekly Scheduling, FUNCTIONS Station PSC-A64S is suitable for providing convenient • Run/Stop* • Fan Speed
• Operation Mode • Louver
Accumulated Operating Time, etc., help you save • Run/Stop/Abnormality • Setting Temperature monitoring of indoor climates. It controls up to 160 indoor Control Function • Temperature Setting
• RCS Operation Prohibited Setting • RCS Operation Prohibited
energy. As many as 64 remote-controlled groups and Monitor Function • Accumulated Operating Time units and up to 8 sub-controllers can be connected via • Filter Sign Reset
• Operation Mode • Setting Fan Speed
up to 160 indoor units can be connected to a single air- • Setting Louver • Filter Sign • Alarm Code H-LINK. In addition to setting the operation mode and *: “All Groups Run/Stop” command signal exception function for selected
• Run/Stop* • Fan Speed groups is available by “Exception of Run/Stop Ope.” function.
conditioning system. • Operation Mode • Louver
temperature, PSC-A64S also gives you advanced control
Control Function • Temperature Setting
• RCS Operation Prohibited
over air quality and louver orientation. Should a problem
• Filter Sign Reset occur, a dedicated alarm code helps you identify the issue. 65
*: “All Groups Run/Stop” command signal exception function for selected
groups is available by “Exception of Run/Stop Ope.” function. 66