0% found this document useful (0 votes)
367 views116 pages

Design Analysis and Optimization of Offshore Module

This master's thesis involves structural analysis and optimization of a topside module through computer modeling and simulation. The primary goals are to design a structure that is sufficiently strong for transportation, installation, and operation loads while maintaining an optimal weight. Software tools like SESAM GeniE, Presel, Prepost, Framework and Xtract were used for modeling, analysis, and reporting. Key aspects of the study included evaluating design rules, optimizing frame configurations, analyzing critical joints, and ensuring structural capacity and safety under all load conditions. The results demonstrated the module has sufficient strength for all design scenarios. Local analysis of lifting points also confirmed their load capacity was adequate.

Uploaded by

Mircea
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
367 views116 pages

Design Analysis and Optimization of Offshore Module

This master's thesis involves structural analysis and optimization of a topside module through computer modeling and simulation. The primary goals are to design a structure that is sufficiently strong for transportation, installation, and operation loads while maintaining an optimal weight. Software tools like SESAM GeniE, Presel, Prepost, Framework and Xtract were used for modeling, analysis, and reporting. Key aspects of the study included evaluating design rules, optimizing frame configurations, analyzing critical joints, and ensuring structural capacity and safety under all load conditions. The results demonstrated the module has sufficient strength for all design scenarios. Local analysis of lifting points also confirmed their load capacity was adequate.

Uploaded by

Mircea
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 116

FORWARD

This report is written by Zelalem Teshome Hika, and submitted as part of the requirements for
completion of Master degree in Offshore Structural Engineering at University of Stavanger
department of construction techniques and material technology. The terms of the assignment
is from January to June 2012

Offshore structures may be defined as structures that have no fixed access to dry land. Such
structures are highly exposed to environmental loadings, and required to withstand and
overcome all conditions.

The main purpose of offshore structural analysis is to ensure that all offshore operations shall
be performed in safe manner with respect to safety environment and economical risk.

The purpose of this thesis work is:-


 Learn to use SESAM GeniE for modelling the geometry and loads of the topside
module.
 Learn to use SESAM Presel, Prepost, Framework and Xtract for structural analysis
and reporting.
 Evaluation and implementation of relevant rules for offshore construction.
 Design and analysis of a module for relevant loads and control Phases such as
transport, installation and operation.
 Optimize the frame/trusses configuration and selection of profile types to achieve
optimal design with respect to weight considering, inplace, lift and transport condition.
 Local design of joints, lifting point and lifting pad eyes.

This master thesis has been carried out under the supervision of Rolf A. Jakobsen and
Associate professor Siriwardane, S.A.Sudath C at university of Stavanger.

I would like to express my gratitude to my principal supervisors Rolf A. Jakobsen and


Associate professor Siriwardane, S.A.Sudath C for their inspiration, follow-up and great
advices.

I would like to thank Aker Solutions for giving me the opportunity to work on my master
thesis with them and particularly I would like to express my deepest gratitude to my assistant
supervisor Johan Christian Brun for his support and wonderful inspiration throughout, in such
a way that I feel that I have gained greater understanding of this discipline.

I would like to thank also the rest of engineers in structural analysis group at Aker Solutions
for their friendly and great advices.

Finally I would like to thank my parents, brothers, sisters and friends for their support and
inspiration during my study.

Stavanger 14.06.2012

Zelalem Teshome Hika

i
SUMMARY
The structural analysis of a topside module presents many technical challenges that have to be
designed to overcome in efficient manner to meet a proper weight and strength control with
respect to all conditions

The primary purpose and goal of the structural design analysis and optimization of this master
thesis is to maintain proper weighed structure that has sufficient capacity and strength with
respect to transportation, installation and operation. Apart from that the design analysis and
optimization of this topside structure is to achieve a structure that has high safety with respect
to life, environment and economic risk.

On preparation of analysis hand calculation of wind load, center of gravity and barge
acceleration load were prepared.

During modeling, design analysis and optimization the following software tools were learned
and utilized.
 SESAM GeniE for modeling the geometry and loads of the topside module
 SESAM Presel, Prepost, Framework and X-tract for structural analysis and reporting

In addition the following issues were considered.


 Evaluation and implementation of relevant rules for offshore construction;
 Optimize the frame/trusses configuration and selection of profile types to achieve
optimal design with respect to weight considering, transport, inplace and lifting
conditions;
 Design and analysis of the topside structure for relevant loads and control Phases;
 Local design of joints, lifting point and lifting pad eyes.

The structural design and analysis are performed considering the inplace as the basic and first
stage of the process. Transport condition was second stage, considering barge accelerations,
wind and sea fastening. Failing members could indicate a need for temporary reinforcements.
All temporary reinforcements considered to be removed after the installation.

Lifting condition was the final stage. During lifting all temporary reinforcements will
naturally be present.

Local design and analysis of lifting padeyes was performed for padeye loading capacity of
1500 tons.

Local analysis of joints for selected critical joints for inplace and lift conditions are detailed
analysed and joints which had insufficient capacity were reinforced and analysed.

The results from the analysis reveal that the module has sufficient capacity to all design
conditions.

The local analysis results for lifting padeyes show that the lifting padeye has sufficient
capacity with respect to stresses in pin and eye, tensile stress next to the eye, shear stress in
the pad eye plate and weld strength. The local analyses of critical joints results reveal that all
critical joints have sufficient capacity with respect to design criteria and rules.

ii
ABBREVIATIONS

ALS Accidental Limit State


CoG Centre of Gravity
CoGE Centre of Gravity Envelope
CND Operational, Storm or earthquake condition
DAF Dynamic Amplification Factor
DC Design Class
DNV Det Norske Veritas
FLS Fatigue Limit State
HSE Health Safety and Environmental
IR Interaction Ratio
IDC Inter Discipline Check
LC Load Case
Lbuck Length between lateral support of compression flange
MEL Master Equipment List
MSF Module Support Frame
MTO Material take-off
NS Norsk Standard
PSA Petroleum Safety Authority Norway
SDOF Single Degree of Freedom
SOP Swinging Object Protection
SI System International
SKL Skew Load Factor
SLS Serviceability limit state
SMYS Specified Minimum Yield Strength
SWL Still Water Level
UF Utility Factor
UFL Unsupported Flange Length
ULS Ultimate Limit State
V Mises Equivalent stress used in von Mises stress check
WLL Working Limit Load
WCF Weight Contingency Factor

iii
TABLE OF CONTENTS

FORWARD .............................................................................................................................................. i
SUMMARY ............................................................................................................................................ ii
ABBREVIATIONS ................................................................................................................................ iii
TABLE OF CONTENTS ....................................................................................................................... iv
1 INTRODUCTION .......................................................................................................................... 1
1.1 BACKGROUND ..................................................................................................................... 1
1.2 SCOPE..................................................................................................................................... 2
1.3 REPORT STRUCTURE ......................................................................................................... 2
2 DESIGN CONSIDERATIONS ...................................................................................................... 3
2.1 ANALYSIS METHOD ........................................................................................................... 3
2.2 DESIGN REQUIREMENTS AND CRITERIA...................................................................... 3
2.3 MATERIAL PROPERTIES .................................................................................................... 4
2.4 CROSS SECTIONS ................................................................................................................ 4
2.5 DESIGN ANALYSIS AND OPTIMIZATION PLAN ........................................................... 5
3 COMPUTER MODELLING .......................................................................................................... 6
3.1 GENERAL .............................................................................................................................. 6
3.2 COORDINATE SYSTEM ...................................................................................................... 6
3.3 UNITS ..................................................................................................................................... 6
3.4 MEMBER, JOINTS AND DECK PLATE MODELING ....................................................... 6
3.5 BOUNDARY CONDITIONS ................................................................................................. 7
3.6 CODE CHECK PARAMETERS ............................................................................................ 8
4 ACTION AND ACTION EFFECTS .............................................................................................. 9
4.1 DEAD LOADS........................................................................................................................ 9
4.2 LIVE LOADS........................................................................................................................ 10
4.3 ENVIRONMENTAL LOADS .............................................................................................. 10
4.3.1 WIND ACTIONS .......................................................................................................... 11
4.3.2 WAVE ACTIONS ......................................................................................................... 12
4.3.3 EARTHQUAKE LOADS ............................................................................................. 12
4.3.4 TRANSPORT ACCELERATION ................................................................................ 12
5 GLOBAL STRUCTURAL ANALYSIS AND OPTIMIZATION ............................................... 13
5.1 INPLACE CONDITION ....................................................................................................... 15
5.2 LIFTING CONDITION ........................................................................................................ 20
5.3 TRANSPORT CONDITION................................................................................................. 24
6 DESIGN PADEYES ..................................................................................................................... 28
6.1 LOCAL ANALYSIS OF PADEYES .................................................................................... 28
6.2 DESIGN CHECK OF PADEYES ......................................................................................... 29
7 DESIGN OF JOINTS ................................................................................................................... 32
7.1 LOCAL ANALYSIS OF JOINTS......................................................................................... 32
7.2 DESIGN CHECK OF JOINTS ............................................................................................. 32
8 DISCUSSION ............................................................................................................................... 34
9 CONCLUSIONS .......................................................................................................................... 36
REFERENCES ...................................................................................................................................... 38
APPENDIXES....................................................................................................................................... 39
A. GEOMETRY ................................................................................................................................ 40
B. JOINTS ......................................................................................................................................... 44
C. SECTION PROPERTIES ............................................................................................................. 48
D. ACTIONS ..................................................................................................................................... 53
E. GLOBAL ANALYSIS ................................................................................................................. 79
F. DESIGN CHECK OF PADEYES ................................................................................................ 99
G. DESIGN CHECK OF JOINTS ................................................................................................... 104

iv
1 INTRODUCTION
1.1 BACKGROUND
An offshore structure may be defined as a structure that has no fixed access to dry land and is
required to stay in position in all weather conditions. Major offshore structures support the
exploration and production of oil and gas from beneath the seafloor.

The design, analysis and construction of these structures are one of the most demanding sets
of tasks faced by engineering profession.

Offshore structures may be fixed to the seabed or may be floating. Floating structures may be
moored to the seabed, dynamically positioned by thrusters or may be allowed to drift freely.
Offshore structures should experience minimal movement to provide a stable work station for
operations such as drilling and production of oil and gas. Offshore structures are typically
built out of steel, concrete or a combination of steel and concrete, commonly referred to as
hybrid construction.

The environment as well as financial aspects offshore requires that a high degree of
prefabrication be performed onshore. It is desirable to design so that offshore work is kept to a
minimum.

The overall cost of an offshore man-hour is approximately five times that of an onshore man-
hour. The cost of construction equipment required to handle loads, and the cost for logistics
are also much higher in offshore. These factors combined with the size and weight of a
structure requires that the design must carefully consider all construction activities between
shop fabrication and offshore installation. Ref. [23]

This master thesis presents the global design analysis and optimization of an offshore topside
module which has a dimension of 40m x 20m x 20m length, width and height respectively.

The main goal of this master thesis is Optimization of structural member profiles and this
thesis illustrates the strategy and procedure of performing a design optimization of a topside
offshore module considering all the construction phases and design conditions.

Inplace, lifting and transport design analysis are performed using SESAM software package
for global analysis of the topside module.

Local analysis of lifting padeyes, lifting points and joints are also performed with hand
calculation and Excel software tools. The global and local analysis covers ULS and ALS
condition are carried out in accordance with prevailing design rules and standards.

The design of offshore structures has to consider various requirements of construction relating
to:
 Weight
 Load-out
 Sea transport
 Offshore lifting operations
 Hook-up
 Commissioning

1
The work performed in this report will be limited and concentrate on weight control, capacity
and optimizations of member for transportation, lifting and operating phases and local
analysis of lifting padeyes, lifting points and critical joints.

1.2 SCOPE
 Learn to use SESAM GeniE for modelling the geometry and loads of the topside
module.
 Learn to use SESAM Presel, Prepost, Framework and Xtract for structural analysis
and reporting.
 Evaluation and implementation of relevant rules for offshore construction.
 Optimize the frame/trusses configuration and selection of profile types to achieve
optimal design with respect to weight considering, transport, lifting and operating
conditions.
 Design and analyse the module for relevant loads and control phases such as transport,
installation and operation.
 Local design and analysis of lifting padeyes, lifting point and critical joints.

1.3 REPORT STRUCTURE


The structure must be designed to resist static and dynamic loads. Chapter 2 discusses the
general requirement of relevant techniques with respect to offshore structural design
consideration. Chapter 3 presents the systematic approach to model the structure. Chapter 4
presents all the basic loads on the module. Chapter 5 presents action combination and
structural analysis for inplace, lift and transport phases and global analysis the structure for all
construction phases. Chapter 6 presents the local lifting padeye analysis. Chapter 7 considers
methods of determining the static strength of local joint and analysis is performed and
presented. In chapter 8 the discussion part of the analysis and optimization are presented and
chapter 9 will presents the conclusion part of this thesis. References and Appendixes are
presented at the end of this report.

2
2 DESIGN CONSIDERATIONS
2.1 ANALYSIS METHOD
The module shall be analysed by use of the SESAM suit of programs, and includes the
following:

 GeniE for geometry and load modelling


Pre-processor for modelling beam/shell/plate structure
Pre-processor for applying equipment loads and actions

 Presel for super element assembly and load combining


Supper element and load assembly pre-processor
Use first level super elements created by GeniE to create higher order super elements
Assembles loads/actions from GeniE and create load combinations

 SESTRA for stiffness calculations


Solve the finite element equations

 Prepost for combining stiffness matrices and final load combinations


Conversion of finite element model, loads and results in to postprocessor data base elements

 Framework for code checks


Code check unit and post processor for finite element analysis

 Xtract for post processing


A post –processor for presentation of results from static structural analyses

2.2 DESIGN REQUIREMENTS AND CRITERIA


Governing law and regulations is the PSA, Ref. [2]. The structural checks will be carried out
in accordance with NORSOK, Ref. [9] and [11], and Euro-code 3, Ref. [15].
The modules shall be code checked for following limit states:

ULS: Limit states that generally correspond to the resistance to maximum applied actions.
Action factors and action combinations with emphasis on ULS are given in chapter 5.
SLS: Limit states that correspond to the criteria governing normal functional use.
If not more stringent functional requirements specified otherwise, the following requirements
for vertical deflection should apply:

Deck beams: Maxdeflection ≤ L/200 Beams supporting plaster or other brittle finish Maxdeflection
≤ L/250 Reference is also made to section 7.2.4 of NORSOK N-001, Ref. [9]. For the
analyses performed, maximum deflection of L/250 is applied.

3
2.3 MATERIAL PROPERTIES
The steel qualities used in the analysis are presented and the strength reduction due to larger
thicknesses (>40mm) shall be according to prevailing standards.

In general, the structural steels applied have the following steel properties and qualities:

Yield strength
Plates 420 MPa

Sections 420 MPa (Welded profiles)


355 MPa (Standard profiles

Further reference is made to [6], [7] and [8]

Any new steel shall comply with requirements set out in the NORSOK standards.

The design resistance shall be determined based on the characteristic values of material
strength reduced by the material factor in accordance with section 7.2 of NORSOK N-001,
Ref. [9]

The following material properties are considered for all steel profiles:

Young’s modulus E = 210000 N/mm2


Shear modulus G = 80000 N/mm2
Density ρ= 7850 kg/ m3
Poisson’s ratio υ = 0.3

MATERIAL FACTOR
Values of material factors can be taken as 1.0 except for ULS in which the following value is
applied:

 1.15 for Structural Steel detail

2.4 CROSS SECTIONS


Loading orientation on the structural member usually influence the selection of section profile
types of the structural members. For this topside structural module, HEB and Square hollow
sections with hot rolled and cold welded profile will be considered.

HEB profile type is most widely used for floor beams and columns because these profiles
have great efficiency in transverse loading.

Rectangular tubes designed as rectangular hollow section widely used for column members
because of their efficiency in axial compression and torsion. Selection of the structural
member is considered the theory behind the structural member responses during transvers
loading and axial loading.

Global analysis of the topside structure will be performed and member utilization factors are
checked. Optimizations are performed for all construction phases. The final selected section
properties of profile types are presented in Table 5-15

4
The general geometry and member names of the module is presented in Appendix A, joints
names in Appendix B and all sections applied are presented in Appendix C

2.5 DESIGN ANALYSIS AND OPTIMIZATION PLAN

The analysis and optimization plan presented below shows the strategy to overcome
optimized and well-integrated structure for inplace, lifting and transport condition.

5
3 COMPUTER MODELLING
3.1 GENERAL
The module is modeled and analyzed by use of SESAM suit of programs.

3.2 COORDINATE SYSTEM


The coordinate system is used is such that Y is pointing North, X is pointing East, Z is
pointing upwards.

3.3 UNITS
The fundamental units (database unites) that used in the analyses are the following SI unites
or multiples of:
Length: meter (m)
Mass: tonne (T) (103kg)
Time: seconds (s)

The resulting force and stresses will then be Mega Newton (MN) and MN/m2 (MPa)
Input units to SESAM GeniE (pre-processor) are as follows:

Length: meter (m)


Mass tonene (T)
Time: second (s)
Force: kilo Newton (kN)

3.4 MEMBER, JOINTS AND DECK PLATE MODELING


A systematic approach to member and joint names will be adopted in the SESAM analyses.

Joint/Point names
Structural joints will have names starting with the letter J for joints and P for points, plus a six
digit number system as follows:
Jxxyyzz (joint)
Pxxyyzz (point)

Where xx,yy and zz are numbers in the range between 00 and 99 indicating the position of the
joint/point in the module’s coordinate system.

Member names
Member names will start with the letter M and used the following notation:

Mαxxyyzz

Where: xx, yy and zz are numbers in the ranger between 00 and 99 corresponding to end 1
joint number. D may be used for dummy elements instead of M. α is a letter according to the
direction of the member:

X- x-direction
Y- y-direction
Z- z-direction

6
A -Brace in the xy-plane running in the positive x-and positive y-direction
B -Brace in the xy-plane running in the positive x-and negative y-direction
C -Brace in the xz-plane running in the positive x-and positive z-direction
D -Brace in the xz-plane running in the positive x-and negative y-direction
E -Brace in the yz-plane running in the positive y-and positive y-direction
F -Brace in the yz-plane running in the positive y-and negative z-direction

Deck members and columns running in the parallel with the axis system shall always run in
the positive direction. Direction of braces shall be such that the x-direction predominate the y-
direction, which again predominates the z-direction. I.e. braces in xy- and xz–plane shall
always run in positive x-direction, while braces in the yz-plane shall run in positive y-
direction.

Plate names
Deck plates will have the following notation:

PLxxyyzz

Where: xx,yy and zz corresponds to the start joint of the plate. The start joint shall be the
lower left corner of the plate with the following joints defined in the counter clockwise
direction.

Joint modeling
Increased stiffness inside joint will in general be neglected, for large prefabricated nodes (e.g.
support nodes) the joint stiffness may be simulated by use of separate elements with increased
stiffness (dummy members). The stiffness of the dummy element shall be evaluated in each
case.

Plate modeling
4- noded quadrilateral shell elements is used to simulate the in-plane shear stiffness of the deck
structures. The plate elements shall not contribute to the strong axis bending stiffness of the deck
girder and will therefore be modeled at the center of the deck girders (the system lines)

Only the shear stiffness of the plate is accounted for in the global module analyses. This is
achieved by use of anisotropic shell element formulation and dividing the x-and y-
components of the elements stiffness matrix by a large number (100 is used).

3.5 BOUNDARY CONDITIONS


The module is subjected to a two-step analysis.

Step one
Comprise dead load only, representing the condition at installation. The boundary conditions
at this stage is statically determined; i.e., no constraint forces will be a strain on the structure

Step two
Step two represents the boundary conditions in operating and transport phases. This means
that all the module supports are pinned, i.e. fixed for translation in all three directions. All
live-, variable- and environmental loads are applied in this step.

7
3.6 CODE CHECK PARAMETERS

Code check of members is performed for ULS-a/b by use of SESAM Framework. Member
checks (yield and stability) are performed according to NS3472, NORSOK N-004 and Euro-
code 3.

Material Factor

The material factor (γm) for structural steel members is 1.15 for ordinary ULS analysis.

Buckling Length Factor(Ly, Lz)

All members will be given default buckling length factor 1.0. However, booking may be set
manually if considered relevant.

Buckling Length

The default buckling length (Ly, Lz) is equal to the member length.
For members being modeled by several elements, the buckling lengths (Ly and Lz) may be
adjusted to the distance between the actual restraints. For deck beams with top flange being
restrained by the deck plate the buckling length for in-plane buckling can be set to a small
length, i.e. 0.1L

Unsupported Flange Length (UFL)

The unsupported length of the compression flanges shall be modeled for lateral buckling
checks of beams and girders. The default UFL is equal to the length of the element. For deck
beams with top flanges being supported by a deck plate and where it can be demonstrated that
the bottom flanges are in tension for all design cases, the UFL may be set to a small length to
suppress the lateral buckling check

8
4 ACTION AND ACTION EFFECTS
A load numbering system is common for this topside module, and applied to first level super
elements. The outline of numbering system is presented in Table 4-1

Load case Description


1-10 Permanent loads representing steel weight
20-27 Permanent loads present at all control phases
31-34 Content weight (mechanical, piping, HVAC, etc.)
50-55 Wind loads
101-134 Horizontal acceleration loading, x-direction
201-234 Horizontal acceleration loading, y-direction
Table 4-1 Outline of the numbering system

4.1 DEAD LOADS


The dead loads include weight of structure, equipment, bulk and other items which form a
permanent part of the installation.

Dead load or permanent load can usually be determined with high degree of precision. Hence,
the characteristics value of a permanent load is usually taken as the expected average based on
actual data of material density and volume and material.
The weight contingency of 1.10 is applied to all permanent loads included as part of the
permanent weight.

The structural weight comprises primary, secondary and outfitting steel. Secondary and out
fitting steel will be a percentage of the primary steel weight, unless a specific weight is
defined.

On preparation of load modeling the total module weight was estimated to be about 2000T.
The module ended up with a total un-factored weight of 1609.30T, split into various
disciplines and deviations of the expected weight are listed in Table 4-2 below.

Basic dead load and live load generated from GeniE input data and SESTRA output are
presented in Appendix D. the dead loads distribution is presented in Table 4-1.

Discipline Relative Actual Deviation


Various equipment 20.9 % 336 1.994378
Electrical Dry Weight 3.9 % 62 -0.59895
Instrumental Dry Weight 1.5 % 24 0.726758
Piping Dry Weight 12.4 % 200 -0.28868
HVAC 1.7 % 28 -0.55598
Safety Dry Weight 1.7 % 28 -0.40797
Surface Dry Weight 0.7 % 12 -0.65465
Architectural Dry weight 3.0 % 48 -0.56831
Self Generated Dead Weight 36.1 % 580.9
Secondary Steel 14.4 % 232.3 -0.27476
Outfitting Steel 3.6 % 58.1 -0.47408
100.0 % 1609.3
Table 4-2 Load distribution

9
4.2 LIVE LOADS

Live loads or variable functional loads are associated with use and normal operation of the
structure
The live loads that usually must be considered are

 Weight of people and furniture


 Equipment and bulk content weights
 Pressure of contents in storage tanks
 Laydown area and live load on deck

The choice of the characteristic values of live load is a matter of structure. In general
inventory and Equipment Live Loads shall be taken from the Master Equipment List and/or
Weight Report and be distributed according to reported CoG coordinates but on this report the
weight distribution is taken from Aker solutions list of weight report.

There is always be a possibility that live load will be exceeded during life time of the
structure. The probability for this to happen depends on the life time and the magnitude of the
specified load. In general during the course of the life of the platform, generally all floor and
roof areas can be expected to support loads additional to the known permanent loads.

Variable deck area actions are applied in the structural check to account for loose items like
portable equipment, tools, stores, personnel, etc. Deck area actions are applied in accordance
with NORSOK, N-001 Ref. [9]

4.3 ENVIRONMENTAL LOADS

Environmental loads, is associated with loads from wind, snow, ice and earthquake. Within
the design of offshore structures wave and current loads also belongs to this group.

For wind and snow statistical data are available in many cases. In connection with the
determination of characteristic load, the term mean return value is often used. This is the
expected number of years between a given seasonal maximum to occur.

Offshore structures are highly exposed to environmental loads and these loads can be
characterized by:

 Wind speed and air temperature


 Waves, tide and storm surge, current
 Ice (fixed, floes, icebergs)
 Earthquake

10
4.3.1 WIND ACTIONS

The wind load which is applied on the structure is based on static wind load and basic
information is presented below.

Reference wind speed applied on a module is the 1-hour, all year Omni directional wind
speed at 10m above LAT:

U1h, 10m, 1y = 25.5 m/s


U1h, 10m, 10y = 29.5 m/s
U1h, 10m, 100y = 34.0 m/s

The global ULS inplace analyses will be based on the 3-second gust wind (L < 50m). Local
checks, if applicable, of stair towers, crane, wind cladding, etc. should be based on the 3-sec
gust wind.

For simplicity the wind load in the module analyses will be based on a constant wind speed at
an elevation located ¾ of the module height.

The static wind load is calculated in accordance to NORSOK N-003 section 6.3.3. For
extreme conditions, variation of the wind velocity as a function of height and the mean period
is calculated by use of the following formulas:

The wind loads are calculated by the following formula:

F = ½ · ρ · Cs · A · Um2 · sin (α)

Where:
ρ =1.225 kg/m3 mass density of air
Cs shape coefficient shall be obtained from DNV-RP-C205,
A area of the member or surface area normal to the direction of the force
Um2 wind speed
α angle between wind and exposed area

The characteristic wind velocity u (z,t)(m/s) at a height z(m) above sea level and
corresponding averaging time period t less than or equal to t0 = 3600 s may be calculated as:

U(z,t) = Uz [1-0.41Iu(z) ln (t/t0)]

Where, the 1 h mean wind speed U(z)(m/s) is given by


U(z) = U0[1+C ln(z/10)]

C = 5.73 * 10 -2 (1 + 0.15 U0) 0,5


Where, the turbulence intensity factor Iu (z) is given by

Iu(z) =0.061[1+0.043U0](z/10)-0.22

Where, U0 (m/s) is the 1 h mean wind speed at 10m

11
The wind load calculations performed for operational and transport phases are presented in
Appendix D.

4.3.2 WAVE ACTIONS


Wave load is not relevant for structures positioned higher than 25 meter above sea level. It is
considered that the module presented on this report has sufficient height above sea level to
avoid direct wave loading.

4.3.3 EARTHQUAKE LOADS


Structures shall resist accelerations due to earthquake. The 100 year earthquake accelerations
for this topside structure are 0.051g horizontal and 0.020g vertical. Ref. [18]
Accidental earthquake condition is also considered for inplace design and the values are
presented in Table 4-3 below.

Earthquake load 100 years 10000 years


X direction 0.051g 0.245g
Y direction 0.051g 0.255g
-Z direction 0.020g 0.061g
Table 4-3 Earthquake acceleration

Earthquake with annual probability of 10-2 can be disregarded according to NORSOK N-003
Section 6.5.2 Ref. [10]

4.3.4 TRANSPORT ACCELERATION


The transport analysis will consider ULS-a/b load conditions with module dry weight
(including temporary reinforcement), CoG shift factor, transport accelerations and wind.
Wind loads and accelerations are applied in eight directions at 45 degrees interval covering
the complete rosette, and is presented in Figure 4-1.

Figure 4-1 Directions of horizontal accelerations and wind

The barge acceleration is calculated according to Noble Denton Ref. [20] and detail calculation
is presented in appendix D. Result are presented in Table 4-4

DIRECTION ACCELERATION
X 1.054g
Y 0.662g
Z 0.200g
Z -0.200g
Table 4-4 Barge motion acceleration

12
5 GLOBAL STRUCTURAL ANALYSIS AND OPTIMIZATION
The aim of structural design analysis is to obtain a structure that will be able to withstand all
loads and deformations to which it is likely to be subjected throughout its expected life with a
suitable margin of safety. The structure must also fit the serviceability requirements during
normal use.
The various performance and use requirements are normally specified in terms of LIMIT
STATES. For steel structures the limit states may be categorized as follows:

 Ultimate limit states (ULS), corresponding to the maximum load carrying capacity.
 Fatigue limit states (FLS), related to the damaging effect of repeated loading.
 Serviceability limit states (SLS), related to criteria governing normal use and durability.
 Accidental limit states (ALS), corresponding to accidental moments during operation.

The design of structure may be divided into three stages. These are:

Functional planning
This problem in design is the development of a plan that will enable the structure to fulfill the
purpose for which it is built.

Cost estimate
Tentative cost estimate are developed for several structural layout

Structural analysis
Selection of the arrangement and sizes of the structural elements are decided so that the
service loads may be carried with a reasonably factor of safety.

Offshore structures are not fabricated in their final in-service position. Therefore, a detail
design must consider the following stages:

 Fabrication and erection


 Load out from fabrication yard to barge
 Transportation from yard to offshore site on a barge
 Lift from barge to final position
 Inplace operating and accidental conditions

It is necessary to consider all accidental stages as different members may be critical in


different cases. In practice, the first two cases will be checks of the structure whereas the
transport, lifting and operating conditions are governing for the design and final lay-out. This
is because the fabrication, erection and load out methodology can be varied to suit the
structure, but the other load cases are fundamental in the structure design. Analyses were
therefore carried out for three primary load conditions, inplace, lift and transportation.

A brief discussion of the various load effects on the topside structure will be given in the
present chapter. Finally, the Ultimate limit state check for all conditions will be illustrated. All
loads that may influence the dimensioning are to be considered in the design analysis. Linear
elastic design techniques have been applied almost exclusively to design structural steel work
in offshore topside modules.

13
Structural analysis shall include all design conditions that required to cover the design limit
states as specified by the PSA Ref.[1], and NORSOK N-001 Ref.[9]. Actions shall be
combined in accordance with NORSOK N-003.

The combinations applied in the analysis are presented in Table 5-1below. Wave and current
are not applicable for this module.

Ice only to be combined with 10-1 wind and due to the small loads it is considered negligible.

Snow loads are assumed to have minimal effect on this, and are therefore considered
negligible

Limit states Wind Wave Ice Snow Earthquake


100 100 - - -
ULS - - - - 100
SLS 100 100 - - -
ALS - - - - 10000
Table 5-1 Environmental action combinations

ALS 10 000-year wind is not governing due to reduced load- and material factors, and for
these analyses, it will be neglected.
The action factors to be used for the various limit states are presented in Table 5-2 below.

Load combination P L E D A
ULS-a 1.3 1.3 0.7 1.0 -
ULS-b 1.0 1.0 1.3 1.0 -
SLS 1.0 1.0 1.0 - -
ALS 1.0 1.0 - - 1.0
Table 5-2 Action factors

Where:

P = Permanent loads
L = Variable functional loads (Live loads)
E = Environmental loads
D = Deformation loads
A = Accidental loads

14
5.1 INPLACE CONDITION

Inplace load combinations shall consider ULS – a/b load conditions with contribution from
relevant load types as defined in chapter 4. Load combinations are established to give
maximum footing reactions at the interface between the modules and the Main Support Frame
(MSF).

Environmental loads wind, earthquake and barge accelerations shall be considered acting
from eight different directions at 45 degrees interval covering the complete rosette.

However, the wind load applied on inplace storm condition is considered East/West only.
Wind load from North and South directions are ignored because of shielding effects. The
module is analysed for wind with average recurrence period of 100 years.

The 100-year ice loads shall be combined with 10-year wind action. Considering the modules
height above water level, Ice load is neglected in the global analysis.

Snow loads shall not be combined with any other environmental loads. Considering the small
load magnitude of 0.5 KN/m2 it is concluded that the snow load can be neglected in the global
analyses.

Maximum deck beam deflections in the SLS condition shall be analysed combining all
permanent loads and variable functional loads. No other environmental loads will be included,
but horizontal displacements at selected spots on the weather deck are reported for 100-year
wind.

The super nodes applied for the boundary conditions for inplace condition are:
 S(301005)
 S(304005)
 S(701005)
 S(704005)

The support points for the inplace condition is to prevent constraint forces, a statically
determined support system (3-2-1-1) is applied on all dead loads.

Action combinations for inplace analysis are performed in Presel. Both Presel load
combinations comprise 3 levels, allowing combining and factoring loads up to a level for final
ULS/SLS/ALS load combination in SESAM Prepost

Basic load cases modeled in SESAM GeniE listed in Table 5-3, Table 5-4 Table 5-5, Table
5-6 and Table 5-7below

15
Load Case Description Direction
1 Self Generated Dead Weight (-Z)
2 Secondary Steel (-Z)
3 Outfitting Steel (-Z)
20 Various Equipment (-Z)
21 Electrical Dry Weight (-Z)
22 Instrumental Dry Weight (-Z)
23 Piping Dry Weight (-Z)
24 HVAC (-Z)
25 Safety Dry Weight (-Z)
26 Surface Dry Weight (-Z)
27 Architectural Dry weight (-Z)

31 Personnel Load (-Z)


32 Weight of gas and liquid in the pipe (-Z)
33 Stored liquids and goods (Tanks) (-Z)
34 Lay-down area (-Z)

Table 5-3 Dead loads and live loads (-Z) direction

Load Case Description Direction


101 Self Generated Dead Weight (+X)
102 Secondary Steel (+X)
103 Outfitting Steel (+X)
120 Various Equipment (+X)
121 Electrical Dry Weight (+X)
122 Instrumental Dry Weight (+X)
123 Piping Dry Weight (+X)
124 HVAC (+X)
125 Safety Dry Weight (+X)
126 Surface Dry Weight (+X)
127 Architectural Dry weight (+X)

131 Personnel Load (+X)


132 Weight of gas and liquid in the pipe (+X)
133 Stored liquids and goods (Tanks) (+X)
134 Lay-down area (+X)

Table 5-4 Dead and live loads (+X) direction

16
Load Case Description Direction
201 Self Generated Dead Weight (+Y)
202 Secondary Steel (+Y)
203 Outfitting Steel (+Y)
220 Various Equipment (+Y)
221 Electrical Dry Weight (+Y)
222 Instrumental Dry Weight (+Y)
223 Piping Dry Weight (+Y)
224 HVAC (+Y)
225 Safety Dry Weight (+Y)
226 Surface Dry Weight (+Y)
227 Architectural Dry weight (+Y)

231 Personnel Load (+Y)


232 Weight of gas and liquid in the pipe (+Y)
233 Stored liquids and goods (Tanks) (+Y)
234 Lay-down area (+Y)

Table 5-5 Local Dead and live loads (+Y) direction

Load Case Description Direction


50 Wind load from west (+X)
51 Wind load from East (-X)
Table 5-6 Wind loads

Load case Description Direction


101 Earthquake 10-2 (-Z)
102 Earthquake 10-2 (+X)
103 Earthquake 10-2 (+Y)
201 Earthquake 10-4 (-Z)
202 Earthquake 10-4 (+X)
203 Earthquake 10-4 (+Y)
Table 5-7 Earthquake loads

Model geometry, load geometry and load footprint are presented on Figure 5:1, 5:2 and 5:3
respectively and detail model geometry for inplace operational state is presented in
Appendix:-A

17
Figure 5-1 Numerical model of the module

Figure 5-2 Numerical model of the load

Figure 5-3 Numerical model of load and footprints

18
ULS DESIGN CHECK

The objective of structural analysis is to determine load effects on the structure such as
displacement, deformation, stress and other structural responses. These load effects define the
sizing of structural components and are used for checking resistance strength of these
components comply with limit state criteria defined by design rules and codes.

The structural analysis of the module for inplace condition is based on the linear elastic
behavior of the structure. As mentioned earlier the module is exposed to different loads. The
structural weight and permanent loads are considered as time-independent loads. Further, the
environmental loads are considered as time-dependent loads. Different wind durations are
calculated and 3seconed wind gust is selected and applied to compute the static wind load for
100 year return period.

These analyses are performed and results presented for each condition and. The Framework
member check for inplace conditions shows that except MY302030 all members of the
structure have utilization factor less than one for the applied loads in inplace operational
condition. This means that the members have sufficient capacity to withstand the applied
loads.

MY302030 fails the initial code check in Framework. However, the beam is reassessed and
found to be have sufficient capacity. Refer to Appendix E for further details

Yield, stability and deflection checks are performed as applicable for the relevant design
conditions according to criteria given in Section 2.3. Framework results for members with
utilization factor greater than 0.80 are presented in Table 5-8 below.

Member Load case Outcome Utility Factor Reassessment


MY302020 543 Failure StaL 1.024 0.61
MY702020 543 StaL 0.994 -
MY301020 545 StaL 0.934 -
MY701020 546 StaL 0.925 -
MY702020 543 StaL 0.885 -
MY302010 543 StaL 0.883 -
Table 5-8 Utilization factor inplace condition

The maximum displacements of the topside structure result from Xtract shows that the
structural deformation for worst load combinations is within the criteria, Maxdeformation <L/250.

SLS DESIGN CHECK

The objective of this analysis is to satisfy the serviceability limit criteria of the topside
structure and to make sure that the structure remains functional for its intended use.

The topside structure has sufficient capacity under ULS design check and the analysis is
conservative. This result indicates that the structure has sufficient capacity under service limit
state too. Because the SLS criteria states that the load and material factors is 1.0 for dead and
live load and no environmental load will be included. Therefore the SLS criteria are satisfied
during normal use.

19
5.2 LIFTING CONDITION
The purpose of lifting analysis is to ensure that lifting operation offshore shall be performed
in safe manner and in accordance with the regulations in force.

In preparation of offshore lifting analysis structure the following questions play a role:

 Which weather condition?


 What type of lifting?
 What is the best approach?

These questions need to be considered carefully analysis at an early stage of the project. Good
communication between the engineers and operational people is a key factor for success.

Heavy lifting offshore is a very important aspect in a project, and needs attention from start
and throughout the project. Weather windows, i.e. periods of suitable weather conditions, are
required for this operation. Lifting of heavy loads offshore requires use of specialized crane
vessels.

The selected lifting method will impact the design consideration. There are several lifting
methods such as single hook, multiple hooks, spreader bar, no spreader, lifting frame, three
part sling arrangement, four part sling arrangement etc.

Lifting arrangement with spreader bar primarily is used to minimize the axial compression
force on members between the lifting points. In this master thesis the lifting arrangement used
is steel wire with four-sling arrangement which is directly hooked on to a single hook on the
crane vessel as shown in Figure 5:4 and Figure 5-5. The thickest sling currently available now
has a diameter of approximately 500 mm.

For lift condition USL-a is the governing load combination. Additional load factors such as
CoG factor, Dynamic amplification factor, Skew load factor, Design factor and Center of
Gravity envelop factor must be calculated and applied to get the total lifting weight. The
calculation of center of gravity is performed and presented in Appendix D.

Figure 5-4 Numerical model of sling

20
Figure 5-5 Numerical model of lifting

Lifting Design Load Factors

Load factors relevant for lifting design are summarized and presented as follows:

Dynamic Amplification Factor (DAF)


Offshore lifting is exposed to significant dynamic effects that shall be taken into account by
applying an appropriate dynamic amplification factor According to DNV .Ref. [21] resulting
DAF comes to 1.30for this module.

Skew Load Factor (SKL)


Skew loads are additional loads from redistribution due to equipment and fabrication
tolerances and other uncertainties with respect to force distribution in the rigging
arrangement.
Single crane four point lift without spreader bar the skew load factor can be taken 1.25

Design Factor (DF)


ᵞ ᵞ
Design load factor DF defined as: DF = F * C
Where
ᵞ = load factor
F

ᵞ =consequence factor
C

Center of Gravity envelope factor (WCOG)


Center of Gravity envelope factor is calculated according Aker solutions working instruction
and presented in appendix D.

21
ULS DESIGN CHECK

As mentioned before the purpose of lifting analysis is to ensure that the lifting operation
offshore shall be performed in safe manner and in accordance with rules and regulations.

During preparation of lifting design analysis, weather window and lifting arrangement with
best approach had to be decided. Global design analysis of the critical members of the topside
module as shown in Figure 5-6

The members are categorized in three groups.

Single critical members, these are members connected to the lifting point and are assigned a
consequence factor of 1.30.
Reduced critical members, these are main members nor connected to the lifting points, and
assigned factor of 1.15.
None critical members, these are members considered to have no impact on the lifting
operation, and are assigned a consequence factor of 1.00

Figure 5-6 depicts the single critical members on the structure. The load factors are applied as
appropriate in Table 5-9 below.

Description Load factor


Weight inaccuracy factor 1.03
Center of gravity inaccuracy factor 1.02
CoG factor 1.10
Skew load factor 1.25
Dynamic amplification factor 1.30
ULS-a load factor 1.30
Consequence factor Lift member 1.30
Lift member reduced consequence 1.15
Non-lift members No consequence 1.00
Table 5-9 Load factors applicable for lifting operation

The super nodes applied for the boundary conditions for lift condition are:
 S(301040)
 S(304040)
 S(701040)
 S(704040)
The tip of the hook is placed at (20m,10m,59m) in x-,y-and z-direction respectively.

22
Figure 5-6 Members at lifting points

Global analysis of the topside structure are performed and presented. The Framework member
check results shows that critical members at lifting point and have sufficient capacity with
respect to structural design criteria.

MY302030 fails the initial code check in Framework. However, the beam is reassessed and
found to be have sufficient capacity. Refer to Appendix E for further details

Members failing the Framework code check are reassessed. Ref. Appendix E

Utilization factors larger than 0.80 are presented in Table 5-10 below. UFs > 0.40 for single
critical members are listed in Table 5-11

Member Load case Outcome Utility Factor Reassessment


MY302030 1 Lbck 1.014 0.62
MY301030 1 Lbck 0.914 -
MY501020 1 StaL 0.909 -
MY701030 1 Lbck 0.887 -
MY702030 1 Lbck 0.863 -
MY302040 1 StaL 0.845 -
MY301040 1 StaL 0.810 -
MY702040 1 StaL 0.800 -
Table 5-10 Utilization factor lifting condition

Member Load case Outcome Utility Factor


MX601040 2 StaL 0.676
MX301040 2 StaL 0.660
MX304040 2 StaL 0.611
MX604040 2 StaL 0.542
MX651030 2 AxLd 0.444
MD301040 2 AxLd 0.430
Table 5-11 Utilization factor lifting condition for critical members

23
5.3 TRANSPORT CONDITION
Transportation in open sea is a challenging phase in offshore projects. This phase need careful
planning analysis and solutions to achieve a safe transport.

Transporting can be done on a flattop barge or on the deck of the heavy lift vessel [HLV].
This thesis is based on a standard North Sea barge, 300ft x 90ft, for the transport phase.
However, if transported on a known vessel or a HLV, the barge acceleration could be reduced
considerably.

Barge accelerations
Barge accelerations are action loads which will be applied on the module in transportation
condition. The intention with barge acceleration calculation is to identify applicable
accelerations for the barge tow and to calculate the acceleration load that will be applied on
the structure. These acceleration loads will be calculated and applied according to Nobel
Denton, Guidelines for marine transportations Ref. [20]

Calculations of barge acceleration loads for transport on the deck of a North Sea barge are
based on the Noble Denton criteria; refer to section 7.9, Table 7-2 Default Motion Criteria.
Transport accelerations are calculated based on the parameters; L>76m and B>23 as shown in
Table 5-1 below, and assuming the most unfavourable position on deck. These parameters are
considered to be conservative.

The physical size of a barge is important with regards to the operational weather window
because this can give a possibility to change the position of the structure and vessel coordinate
system is presented shown in Figure 5-6 below.

Barge motions are loads that influence the structural stability and strength capacity. Refer to
Appendix E for calculation details of barge accelerations.

Vessel type T Single amplitude Heave


Full cycle period (all categories) acceleration
Roll Pitch

Standard North Sea barge 10 secs 20º 12.5º 0.2g


Table 5-12 Applied Noble Denton Criteria

Weather window needs to be suitable during transportation. The module will be analysed for
wind with average recurrence period of 1 year in combination with barge accelerations. Both
wind and accelerations are applied I eight directions with 45o intervals, completing the entire
rosette as showed in Figure 5-8. Wind load cases and directions are presented in Table 5-13
below.

Load Case Description Direction


52 Wind load from west (+X)
53 Wind load from south (+Y)
54 Wind load from East (-X)
55 Wind load from North (-Y)
Table 5-13 Basic wind loads

24
Figure 5-7 Vessel coordinate system

Figure 5-8 Direction of wind load

The transportation and installation of the large topside modules offshore is unique. The
reserve capacity built in to the design provides additional safety in the critical components of
the structure. The support points for the transport condition is chosen as the same as for the
in-place. To prevent constraint forces, a statically determined support system (3-2-1-1) is
applied on all dead loads. The support points are same as for inplace analysis.

During transport the module will be subjected to wind and acceleration loads. The module
will have a (2-2-2-2) support system in the same supports as above. In addition, sea fastening
in each corner will restrain horizontal movements.
The boundary conditions applied during transportation is presented in Figure 5-9 below.

Figure 5-9 Boundary conditions for during transportation

25
ULS DESIGN CHECK

Several members failed the initial Framework code check. To overcome this it was necessary
to either change the profile or introduce some temporary transportation reinforcements.
During the process of optimization, the solution was a combination of both. These temporary
reinforcements are shown in Figure 5-10 and Figure 5-11 below and shall be removed after
installation.

Figure 5-10 Reinforcement members for transport condition

Figure 5-11 Reinforcement members for transport condition

26
After temporary reinforcement and upgrading some members still failed the initial code check
in Framework. However, the beams are reassessed and found to be having sufficient capacity.
Ref. Appendix E for details.
Members with UF > 0.90 are listed in Table 5-14

Member Load case Outcome Utility Factor Reassessed


MX601020 601 Fail StaL 1.029 0.59
MX301020 609 Fail StaL 1.029 0.59
MX304020 609 Fail StaL 1.013 0.59
MD454020 617 Fail StaL 0.997 -
MX604020 601 StaL 0.994 -
MC504010 625 StaL 0.985 -
MD304020 617 StaL 0.968 -
MD451020 617 StaL 0.967 -
MC501010 625 StaL 0.955 -
MC604010 625 StaL 0.941 -
MD301020 601 StaL 0.911 -
Table 5-14 Utilization factor transport condition

To achieve sufficient capacity to withstand the worst load cases during inplace, lift and
transport conditions, the following cross sections have been selected as shown Table 5-15
below.
.
Member Description Type Height Width t-flange t-web
[mm] [mm] [mm] [mm]
B020216 Hot rolled Box 200 200 16 16
B040420 Hot rolled Box 400 400 20 20
B040430 Welded Box 400 400 30 30
B040440 Welded Box 400 400 40 40
B060640 Welded Box 600 600 40 40
HE600B Hot rolled HEB 600 300 155 30
HE800B Hot rolled HEB 800 300 175 33
HE1000B Hot rolled HEB 1000 300 190 36
I08402035 Welded I-girder 800 400 35 20
I1042035 Welded I-girder 1000 400 35 20
I1242035 Welded I-girder 1200 400 35 20
I1252035 Welded I-girder 1200 500 35 20
SUPP Support 850 850 60 60
dummy members
Table 5-15 Cross sections of the structure

27
6 DESIGN PADEYES
6.1 LOCAL ANALYSIS OF PADEYES
Padeyes are applied on lift attaching the sling for lifting operation. Several calculation methods
are available, but in this report Aker Solutions Working instruction for Padeye design and
strength assessment of padeyes is used.

The following stresses are evaluated and presented:

 Pin hole stress


 Main plate stress
 Cheek plate stress
 welds

Padeye plate structures are designed to sustain actions of the heaviest loaded lifting point. In
order to guarantee structural safety as well as economic design of padeyes, comprehensive
analysis should be performed.

Padeye body is usually welded to main structure. In some occasion main body may be welded
to a plate and bolted to main structure for easier removal. Stress check shall be done on body
and welded connection.

All loads are to be transferred from main structure to the padeye structures. The magnitude of
this load or force will be generated from framework analysis result and the padeye will be
designed according to relevant rules and design premises, Aker Solutions working instruction
for padeye design.

On preparation of designing the lifting padeye the following factors needs to be taken into
account:

 Dynamic Amplification Factors


 Skew load factor
 CoG inaccuracy factor
 Weight inaccuracy factor
 Consequence factor

28
6.2 DESIGN CHECK OF PADEYES
The lifting slings must have sufficient length so that angle of the slings meets the criteria set.

To avoid transverse loading on the padeyes, these may be tilted to match the angles of slings.

The geometry of lifting pad eye is shown in


Figure 6-1below and the dimension of padeye hole will be calculated with respect to the
shackle dimension.

Shackle dimensions are taken from Green Pin shackle dimension data sheet Ref.[24] and
presented in Table 6-1.

Figure 6-1 Lifting padeye geometry

Pad eye are frequently applied for use of lifting point, and should be designed to match the
relevant standard shackle dimensions.

Figure 6-1 above depicts the different forces to be considered. In addition, a transverse load
equaling 3% of the sling load should be considered.

According to Aker solutions working instruction Ref. [19] the following criteria should fulfill
during design analysis of lifting padeyes.

Padeye hole diameter is calculated as

D=1.03d’ +2mm……………………..….Eq. (6:1)


The clearance between shackle bolt and pad eye hole should not exceed 4% of the shackle bolt
diameter

Pad eye plate thickness.


Total pad eye thickness T shall fulfill the following criterion: the padeye thickness at the hole
should not be less than 60% of the inside width of the joining shackle.

29
T > 0.6a’ ………………………….…..... Eq. (6:2)
Where: - a’ is the shackle jaw

Increasing of clearance between the pin and the holes result in a decrease in the ultimate
capacity of the pad eye.

The clearance between the pad eye and the shackle jaw should be in the range of 2 to 4mm. a
set of spacer plate should be added if this cannot be achieved by the pad eye thickness with or
without cheek plates.

Pad eye radius


Pad eye radius(R) should be derived by addressing the tear out capacity. In addition, it is
checked towards shackle and sling geometry in terms of sufficient space.
Limits are described by the following formula: -
1.3D< R <2d’ …………………………... Eq. (6:3)
Where: - D = pad eye hole diameter d’ = shackle bolt diameter
R = minimum radius from center of hole to pad eye edge.

Pad eye Height and Length


Pad eye height and length should be decided on the basis of a load distribution perspective and
an operational judgment.

Determination of pad eye geometry and formulas below shows methods to calculate pad eye
height and strength.
Load angle 135deg. > β >45deg.
Where: tc - cheek plate thickness
tp- pad eye plate thickness
R -minimum radius from center of hole to pad eye edge
D=1.03d`+2mm
1.3D < R< 2d`
R=r+tc ........................................................ Eq. (6:4)
Eq. (6:5)

Eq. (6:6)
Height (h) =2r………………......….…..... Eq. (6:7)

Length (l) = 1.8h....................................... Eq. (6:8)

The detailed lifting padeye analysis is performed according to the rules and design premises.
The complete analysis and results are presented in Appendix F

The selected shackle has to house both pad eye and the selected sling. The selected shackle and
pin are presented in Figure 6-2 and Table 6-1.

WLL A B C D E F G H J L
[tons] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

1500 280 290 640 225 360 460 450 1480 1010 1060

30
Table 6-1 Shackle and pin dimensions

Figure 6-2 Shackle geometry

31
7 DESIGN OF JOINTS
7.1 LOCAL ANALYSIS OF JOINTS

Local joint analysis is an important structural analysis to ensure structural integrity.

The mode of failure of a statically loaded joint depends on the type of joint, the loading
conditions and the joint geometrical parameters.

The procedure for stress checks of welded joints are given in documenting the relevant nodes.
The procedure is briefly repeated as follows;

In order to separate and get the proper view of utilization level in different phases, each
analysis condition is treated separately. The method could also be utilized further to combine
all analysis in SESAM, and just check the most critical condition for each node.

First, a yield check of each member ends was performed in Framework, in order to establish
the possible dimensioning load cases for each node. By this, the maximum number of load
combinations to check for is limited by the number of members connected to the node.
Then, joint reaction forces (in the global axis system) are extracted from FRAMEWORK for
the defined load combinations.

A screening was then performed based on a conservative combination of the maximum yield
UF for each member connected at each node, in order to find the most critical node. For nodes
indicated by the screening to be highly utilized, detail calculation was performed in order to
find more correct node UF. Different hot spot in the node were checked towards the Von Mises
criterion, utilizing the correct sign for stresses. In general, conservative combination of normal
and shear stresses are used, giving some conservatism. I.e. Joints that have UF less than 1.05
are acceptable.

Local stability check of stiffeners and web is not performed for the actual nodes. The nodes are
in general robustly stiffened, and local buckling is not considered relevant.

7.2 DESIGN CHECK OF JOINTS


All joints shall be checked for all critical load conditions. Care shall be taken to cover
eccentricities in incoming members if this is not included in the computer analysis. Any
additional moments shall be added to the member forces extracted from the existing analysis.
The following procedure is established to ease the selection of critical load combinations. Excel
spreadsheets will in general be used to process the analysis results and perform detailed node
checks. In order to reduce the required work, several analysis results may be combined by use
of SESAM Prepost prior to the local calculations.

 Perform an ordinary Von Mises check at each member ends and by use of Framework
extract utilization ratios and corresponding load combination, sorted on nodes, and
import into Excel. The number of dimensioning load cases will then be less or equal the
number of incoming members for each node.
 Joint reaction forces are extracted by use of Framework for all joints for identified
dimensioning load cases.

32
 Calculate stresses in critical sections in the node.

 Calculate (multidirectional) equivalent stresses based on the Von Mises yield criterion
and compare with design criteria. For class 1 and 2 sections the stresses may be
calculated based on the plastic moment of inertia. It must then be verified that repeated
yielding does not lead to failure of joints.

 Calculate the local stability usage factor, where considered relevant, based on the stress
calculation from the Von Mises yield check.

The general 3D Von Mises stress calculation formulas as given below is used in order to find
the equivalent stress:

……..Eq. (7:1)

For simplicity reason, the indexing used for shear stresses deviates some from the normal
definition, as e.g. τxy donates shear stress acting in the xy-plane.

A conservative combination of utilization factors may be done as screening, in order to identify


the most critical nodes. The screening results may also be used as an upper limit for the actual
node utilization. The screening may be done by picking the worst UF from transverse beams(x-
direction, longitudinal beams(y-direction) and vertical beams (z-direction including inclined
braces), respectively, and by assuming the worst possible sign combination, the equivalent Von
Mises utilization can be calculated by the following expression;

…Eq. (7:2)

Where:

UFmax ≥ UFmed ≥ UFmin, which indicates that the worst situation is found if the maximum
stress is of opposite sign than the two other components

It should be noted that the screening method described above, may not give a conservative
estimate of the node utilization if the incoming member connection are not full strength
connections or if large shear forces are to be transferred inside the node. Nevertheless, the
screening may be used as a basis for critical node selection also in such cases.

The local joint analyses are performed on selected nodes based o screening results all three
conditions are considered and assessed. The analysis is performed according to Aker solutions
working instructions for joints. Analyses of these selected joints are performed and the
calculation and results are presented on Appendix G

33
8 DISCUSSION
Optimization of the structural designed layout of a topside module with respect to structural
integrity, weight safety and strength capacity is the main task of this master thesis.

As mentioned in previous chapters, the structure is exposed for different types of loads. These
load actions have different effects on the structural behavior of the topside module. The
structural capacity of the module for inplace condition was one of the main issues. It took much
time to achieve optimized structural profiles with respect to intended inplace operation.
However, I learnt that optimizing of the structural profiles has to consider all phases such as
transport and lifting operation, in addition to the inplace operating phase.

To achieve the sufficient capacity and structural integrity, members are carefully selected based
on their strength capacity. Inplace condition is considered as the basis for these selections.

To facilitate transport and/or lifting temporary reinforcements may be used. The main reason
behind this this idea is that inplace operation phase represents a long lasting period. All
conditions need to be considered and the structure will be designed and analyzed with respect
to life, environmental and economic risk. After the analyses and optimizing structural members
for inplace condition, transportation condition is considered and analyzed.

During transport analysis the structure will be analyzed as is (inplace condition) with transport
load combinations and the structural capacity will be studied carefully using Framework
member check result and Xtract for stress and deformation result. These results indicate the
utilization factors, the stress concentrations and deformations of the structural members. This
will lead us to find which part of the structure are most utilized, stressed and deformed.
Studying these structural responses carefully and finding the best engineering solution, the
structure can be modified reinforced to achieve the intended and required results.

The optimized structure for inplace condition was analyzed with the transport load cases. The
result from Framework member check indicated that the structure had insufficient capacity to
withstand these load combinations. The solution was to introduce some temporary
reinforcements to facilitate the transport condition. All temporary reinforcements shall be
removed before operating phase commences.

The last step of the global structural analysis will be lift condition. Lifting will not take place if
there is wind and/or waves. No environmental loads are applicable for lifting analysis. Only
dead loads are included, multiplied by an appropriate factor.

The analysis results of Framework show that the critical member at lifting points have
sufficient capacity to withstand the subjected load during this operation. However, some
members failed the initial code check in SESAM Framework. These beams have been
reassessed and found ok.

Global structural analysis and optimization for inplace, lift and transport conditions are
performed according to rules, codes and design premises. The analysis results show that each
condition has its own influence on how the structural members behave. As we mentioned
earlier, structural members must have a sufficient capacity to withstand all worst load cases and
it must be designed for worst load cases and conditions.

34
Optimizing or upgrading the structural member section property to achieve sufficient capacity
during transport condition reduced the utilization factors of these members for the inplace
condition. However, oil companies are frequently evaluating extension of operational life and
modifications. The extra capacity gained can be considered as a reserve for future
modifications.

The modification of a structure might be necessary in future aspect. This concept indicates that
the reserve capacity of structural strength is an advantage.

In preparation of local lifting padeye analysis of offshore structure, the loads which will be
applied on the padeye structure needs to be evaluated carefully.

Small sling angles will results in undesirable axial loads on members between lifting points.
However, this problem can be reduced by increasing the sling length. This method will increase
the vertical load and reduce the axial compression load on the exposed structural members.
Using spreader bar is another option that can be implemented during lifting arrangement. This
method will eliminate the axial compression loads on the structural members between lifting
points.

Time is a limiting factor for this thesis, and the lifting arrangement selected is a four point
single hook arrangement.

Design and analysis of lifting padeye are performed and presented in appendix F.

However, time limitation the analysis performed on this master thesis considered only four-
sling wire that connected with lifting padeyes and local analyses lifting padeyes are performed
and presented in on Appendix F

Local joint analyses are performed on selected nodes based on screening results. The analyses
and detailed calculations are done in Excel, and presented in Appendix G.

The topside structure has sufficient capacity under ULS design check and the analysis is
conservative. This result indicates that the structure has sufficient capacity under service limit
state too. Because the SLS criteria states that the load and material factors is 1.0 for dead and
live load and no environmental load will be included. Therefore the SLS criteria are satisfied
during normal use.

35
9 CONCLUSIONS

Structural design is very interesting, creative and challenging segment in engineering.


Structures should be designed such a way that they can resist applied forces and do not exceed
certain deformations. Moreover, structures should be economical. The best design is to design a
structure that satisfies the stress and displacement constraints, and results in the least cost of
construction. Although there are many factors that may influence the construction cost, the first
and most obvious one is the amount of material used to build the structure. Therefore,
minimizing the weight of the structure is usually the main goal of structural optimization.

The primary concern of the structural design analysis and optimization of this master thesis was
to obtain a proper weighed structure that has sufficient capacity and strength, with respect to
transportation, installation and operation. Apart from that the design analysis and optimization
of this structure is to achieve a structure that has high safety with respect to life, environment
and economic risk.

In preparation of the structural analyses the basis for the geometry and member properties were
selected for operational phase. However, the topside structure will be exposed for different
conditions before it reaches to the operational state. Lift and transportation phases were studied
and detail analyses were performed. Offshore structures are exposed for different conditions
and it is vital that the structure have sufficient strength and integrity to withstand these loads
and phases.

Strength capacity of a structure can be achieved by different approaches. One approach can be
constructing temporary reinforcement for members to facilitate temporary conditions such as
transport and lifting.

The modeling, design analysis and optimization are performed based on elastic behavior of
structural members. This linear elastic analysis is applied to find the structural members that
have less and high interaction ratio (IR).

The global analysis results have been evaluated and the structure has sufficient integrity and
capacity for all construction phases.

The global analysis of the topside structure shows that the structure at operational phase has
sufficient capacity to withstand the load at operational state, and the utilization factor indicates
the structure has reserve capacity. Oil companies are frequently evaluating extension of
operational life, and/or modifications to enable further facilities and developments. The reserve
capacity of the structure can be used in future modification of the structure.

Finally the global design analyses for inplace, lift and transport phases are performed and
presented. The results imply that the designed structure has sufficient capacity to withstand all
construction phases with respect to design criteria.

Padeye plate structures are designed to sustain actions of the heaviest loaded lift point. In order
to guarantee structural safety as well as economic design of padeyes, comprehensive analysis is
performed analysis result shows that the lifting padeyes have a sufficient capacity to withstand
the loads during lifting operation with respect to design criteria.

36
Local joint analysis is an important analysis in order to guarantee structural safety,
comprehensive local design analyses of selected joints are performed for inplace and lift
conditions. The results show that one joint needs reinforcement. The rest of the selected joints
have sufficient capacity strength to withstand the subjected loads with respect to design criteria
and rules.

The structure must remain functional for its intended use and SLS design check shows that the
structure fit the serviceability requirements during normal use.

Further studying in some areas will be interesting in this master thesis. However, time
limitation and scope of the thesis is too comprehensive to be dealt with in this period.

Areas that could be of interest to look into are:

 Design and analysis of other lifting arrangement that can reduce axial compression loads.

 Calculating reserve plastic capacity of padeye.

 Further Finite-element analysis of stress concentration in padeyes

 Local analysis of joints for transport condition.

37
REFERENCES

[1] PSA “Regulations relating to health, environment and safety in the petroleum activities (The
framework regulations)” and the associated guidelines, 19 December 2003

[2] PSA “Regulations relating to design and outfitting of facilities etc. in the petroleum activities
(The facilities regulations)” and the associated guidelines, 17 December 2003

[3] C007-C-N-SD-101 Structural Design Specification of Offshore Installations. Rev B, Aker


Engineering A.S, 27.06.1990
[4] C007-C-N-SS-600 Design Premises Structural Steel Detail Engineering. Rev 8, Aker
Engineering A.S. 09.11.90
[5] C007-C-N-RD-225 Seismic accelerations for module analysis

[6] C007-C-N-SP-110 Structural Steel Materials, Plates, Rev. B, 27.04.1989

[7] C007-C-N-SP-111 Structural Steel Materials, Rolled Sections, Rev. A, 17.08.1988

[8] C007-C-N-SP-127 High Strength Structural Steel, Plates, Rev. A, 11.07.1989

[9] NORSOK N-001, “Structural design”, rev. 7, June 2010

[10] NORSOK N-003, “Actions and action effects”, rev. 2, September 2007

[11] NORSOK N-004, “Design of steel structures”, rev. 2, October 2004

[12] NORSOK M-101, “Structural steel fabrication”, rev. 4, December 2000

[13] NORSOK M-120, “Material data sheets for structural steel”, rev. 5, November 2008

[14] EN 1993-1-1 Eurocode 3: Design of steel structures - Part 1-1: General rules and rules for
buildings

[15] EN 1993-1-3 "Eurocode 3: Design of steel structures - Part 1-3: General rules

[16] EN 1993-1-8 "Eurocode 3: Design of steel structures - Part 1-8: Design of joints

[17] DNV-RP-C205 “Environmental conditions and environmental loads”, April 2007

[18] C007-C-N-RD-161 Design Resume, D22.Rev.Aker Engineering A.S

[19] Aker Solution working instruction A237-N01, rev.2, “Lifting Design” 26.08.2009

[20] GL Noble Denton 0030/N “Guidelines for Marine Transportations” 31 March 2010

[21] DNV “Rules for Marine Operations, Lifting” January 1996

[22] Ultimate Load Analysis Of Marine Structures, Tore H.Søreide, 2nd edition 1985

[23] Handbook of offshore Engineering, Subrata.K.Chakrabarti, Elsevier Ltd, 1st edition 2005

[24] WWW.Greenpin.com

38
APPENDIXES
A. GEOMETRY ....................................................................................................................... 40
B. JOINTS ................................................................................................................................ 44
C. SECTION PROPERTIES .................................................................................................... 48
D. ACTIONS ............................................................................................................................ 53
Basic dead and live load ....................................................................................................... 54
Presel load combinations ...................................................................................................... 58
Prepost load combinations .................................................................................................... 67
Wind load calculation ........................................................................................................... 70
Barge motion acceleration .................................................................................................... 76
Center of Gravity check ........................................................................................................ 78
E. GLOBAL ANALYSIS ....................................................................................................... 79
Framework member check ................................................................................................... 80
Member Assessments ........................................................................................................... 94
F. DESIGN CHECK OF PADEYE.......................................................................................... 99
G. DESIGN CHECK OF JOINTS ......................................................................................... 104

39
A. GEOMETRY

Figure A- 1 Member names, main deck

Figure A- 2 Member names, lower mezzanine deck

40
Figure A- 3 Member names, upper mezzanine deck

Figure A- 4 Member names, weather deck

41
Figure A- 5 Member names North face

Figure A- 6 Member names South face

42
Figure A- 7 Member names East face

Figure A- 8 Member names West face

43
B. JOINTS

Figure B- 1 Joint names

Figure B- 2 Joint names

44
Figure B- 3 Joint names

Figure B- 4 Joint names

45
Figure B- 5 Joint names

Figure B- 6 .Joint names

46
Figure B- 7 Joint names

Figure B- 8 .Joint names

47
C. SECTION PROPERTIES

Figure C- 1 Sections of module

Figure C- 2 Sections on main deck

48
Figure C- 3 Sections on lower mezzanine deck

Figure C- 4 Sections on upper mezzanine deck

49
Figure C- 5 Sections on weather deck

Figure C- 6 Sections on North face

50
Figure C- 7 Sections on South face

Figure C- 8 Sections on East face

51
Figure C- 9 Sections on West face

52
D. ACTIONS

Basic dead and live load

Load cases and factor


 Inplace condition
 Lift condition
 Transport condition

Load combination Presel


 Inplace condition
 Lift Condition
 Transport condition

Load combination Prepost


 Inplace condition
 Transport condition

Wind Load Calculation

Barge acceleration

Center of Gravity check

53
BASIC DEAD LOAD WEIGHT SESTRA 100

WEIGHT REPORT SESTRA 100


LC Description X Y Z X Y Z LC X Y Z
TONNE kN
1 Self Generated Dead Weight 580.9 5 699.0 1 0.0 0.0 -5 699.0
2 Secondary Steel 232.4 2 279.6 2 0.0 0.0 -2 279.6
3 Outfitting Steel 58.1 569.9 3 0.0 0.0 -569.9
20 Various Equipment 336.0 3 296.2 20 0.0 0.0 -3 296.2
21 Electrical Dry Weight 62.0 608.2 21 0.0 0.0 -608.0
22 Instrumental Dry Weight 24.0 235.4 22 0.0 0.0 -235.4
23 Piping Dry Weight 200.0 1 962.0 23 0.0 0.0 -1 962.0
24 HVAC 28.0 274.7 24 0.0 0.0 -274.7
25 Safety Dry Weight 28.0 274.7 25 0.0 0.0 -274.7
26 Surface Dry Weight 12.0 117.7 26 0.0 0.0 -117.7
27 Architectural Dry weight 48.0 470.9 27 0.0 0.0 -470.9

101 Self Generated Dead Weight 580.9 5 699.0 101 5 699.0 0.0 0.0
102 Secondary Steel 232.4 2 279.6 102 2 279.6 0.0 0.0
103 Outfitting Steel 58.1 569.9 103 569.9 0.0 0.0
120 Various Equipment 336.0 3 296.2 120 3 296.2 0.0 0.0
121 Electrical Dry Weight 62.0 608.2 121 608.0 0.0 0.0
122 Instrumental Dry Weight 24.0 235.4 122 235.4 0.0 0.0
123 Piping Dry Weight 200.0 1 962.0 123 1 962.0 0.0 0.0
124 HVAC 28.0 274.7 124 274.7 0.0 0.0
125 Safety Dry Weight 28.0 274.7 125 274.7 0.0 0.0
126 Surface Dry Weight 12.0 117.7 126 117.7 0.0 0.0
127 Architectural Dry weight 48.0 470.9 127 470.9 0.0 0.0

201 Self Generated Dead Weight 580.9 5 699.0 201 0.0 5 699.0 0.0
202 Secondary Steel 232.4 2 279.6 202 0.0 2 279.6 0.0
203 Outfitting Steel 58.1 569.9 203 0.0 569.9 0.0
220 Various Equipment 336.0 3 296.2 220 0.0 3 296.2 0.0
221 Electrical Dry Weight 62.0 608.2 221 0.0 608.0 0.0
222 Instrumental Dry Weight 24.0 235.4 222 0.0 235.4 0.0
223 Piping Dry Weight 200.0 1 962.0 223 0.0 1 962.0 0.0
224 HVAC 28.0 274.7 224 0.0 274.7 0.0
225 Safety Dry Weight 28.0 274.7 225 0.0 274.7 0.0
226 Surface Dry Weight 12.0 117.7 226 0.0 117.7 0.0
227 Architectural Dry weight 48.0 470.9 227 0.0 470.9 0.0
Figure D-1 Basic Load case SESTRA 100

54
BASIC DEAD WEIGHT LOAD SESTRA 150

WEIGHT REPORT SESTRA 150


Factor X Y Z X Y Z
Z Direction Load CaseDescription kN kN
1 Self Generated Dead Weight 1.1 0.0 0.0 -6 268.9
2 Secondary Steel 1.1 0.0 0.0 -2 507.6
3 Outfitting Steel 1.1 0.0 0.0 -626.9
-9 403.4 1 0.0 0.0 -9 403.3

20 Various Equipment 1.1 0.0 0.0 -3 625.8


21 Electrical Dry Weight 1.1 0.0 0.0 -668.8
22 Instrumental Dry Weight 1.1 0.0 0.0 -259.0
23 Piping Dry Weight 1.1 0.0 0.0 -2 158.2
24 HVAC 1.1 0.0 0.0 -302.1
25 Safety Dry Weight 1.1 0.0 0.0 -302.1
26 Surface Dry Weight 1.1 0.0 0.0 -129.5
27 Architectural Dry weight 1.1 0.0 0.0 -518.0
-7 963.6 2 0.0 0.0 -7 963.5

X Direction
101 Self Generated Dead Weight 1.1 6 268.9 0.0 0.0
102 Secondary Steel 1.1 2 507.6 0.0 0.0
103 Outfitting Steel 1.1 626.9 0.0 0.0
9 403.4 11 9 403.3 0.0 0.0

120 Various Equipment 1.1 3 625.8 0.0 0.0


121 Electrical Dry Weight 1.1 668.8 0.0 0.0
122 Instrumental Dry Weight 1.1 259.0 0.0 0.0
123 Piping Dry Weight 1.1 2 158.2 0.0 0.0
124 HVAC 1.1 302.1 0.0 0.0
125 Safety Dry Weight 1.1 302.1 0.0 0.0
126 Surface Dry Weight 1.1 129.5 0.0 0.0
127 Architectural Dry weight 1.1 518.0 0.0 0.0
7 963.6 12 7 963.5 0.0 0.0

Y Direction
201 Self Generated Dead Weight 1.1 0.0 6 268.9 0.0
202 Secondary Steel 1.1 0.0 2 507.6 0.0
203 Outfitting Steel 1.1 0.0 626.9 0.0
9 403.4 21 0.0 9 403.3 0.0

220 Various Equipment 1.1 0.0 3 625.8 0.0


221 Electrical Dry Weight 1.1 0.0 668.8 0.0
222 Instrumental Dry Weight 1.1 0.0 259.0 0.0
223 Piping Dry Weight 1.1 0.0 2 158.2 0.0
224 HVAC 1.1 0.0 302.1 0.0
225 Safety Dry Weight 1.1 0.0 302.1 0.0
226 Surface Dry Weight 1.1 0.0 129.5 0.0
227 Architectural Dry weight 1.1 0.0 518.0 0.0
7 963.6 22 0.0 7 963.5 0.0
Figure D-2 Basic Load case SESTRA 150

55
BASIC DEAD WEIGHT LOAD SESTRA 200

WEIGHT REPORT SESTRA 200


LC DESCRIPTIONS Factor X Y Z LC X Y Z
Z Direction kN
1 Self Generated Dead Weight 1.1 0.0 0.0 -6 268.9
2 Secondary Steel 1.1 0.0 0.0 -2 507.6
3 Outfitting Steel 1.1 0.0 0.0 -626.9
20 Various Equipment 1.1 0.0 0.0 -3 625.8
21 Electrical Dry Weight 1.1 0.0 0.0 -668.8
22 Instrumental Dry Weight 1.1 0.0 0.0 -259.0
23 Piping Dry Weight 1.1 0.0 0.0 -2 158.2
24 HVAC 1.1 0.0 0.0 -302.1
25 Safety Dry Weight 1.1 0.0 0.0 -302.1
26 Surface Dry Weight 1.1 0.0 0.0 -129.5
27 Architectural Dry weight 1.1 0.0 0.0 -518.0
-17 366.9 397 0.0 0.0 -17 367.0

X Direction
101 Self Generated Dead Weight 1.1 6 268.9 0.0 0.0
102 Secondary Steel 1.1 2 507.6 0.0 0.0
103 Outfitting Steel 1.1 626.9 0.0 0.0
120 Various Equipment 1.1 3 625.8 0.0 0.0
121 Electrical Dry Weight 1.1 668.8 0.0 0.0
122 Instrumental Dry Weight 1.1 259.0 0.0 0.0
123 Piping Dry Weight 1.1 2 158.2 0.0 0.0
124 HVAC 1.1 302.1 0.0 0.0
125 Safety Dry Weight 1.1 302.1 0.0 0.0
126 Surface Dry Weight 1.1 129.5 0.0 0.0
127 Architectural Dry weight 1.1 518.0 0.0 0.0
17 366.9 398 17 367.0 0.0 0.0

Y Direction
201 Self Generated Dead Weight 1.1 0.0 6 268.9 0.0
202 Secondary Steel 1.1 0.0 2 507.6 0.0
203 Outfitting Steel 1.1 0.0 626.9 0.0
220 Various Equipment 1.1 0.0 3 625.8 0.0
221 Electrical Dry Weight 1.1 0.0 668.8 0.0
222 Instrumental Dry Weight 1.1 0.0 259.0 0.0
223 Piping Dry Weight 1.1 0.0 2 158.2 0.0
224 HVAC 1.1 0.0 302.1 0.0
225 Safety Dry Weight 1.1 0.0 302.1 0.0
226 Surface Dry Weight 1.1 0.0 129.5 0.0
227 Architectural Dry weight 1.1 0.0 518.0 0.0
17 366.9 399 0.0 17 367.0 0.0
Figure D-3 Basic Load case SESTRA 200

56
BASIC LIVE LOADS SESTRA 100

WEIGHT REPORT SESTRA 100


LC Description X Y Z X Y Z LC X Y Z
TONNE kN kN
31 Persons Load 412.0 4 041.7 31 0.0 0.0 -4 041.7
32 Weight of gas and liquid in the pipe 40.0 392.4 32 0.0 0.0 -392.4
33 Stored liquid and goods 80.0 784.8 33 0.0 0.0 -784.8
34 Layout Area 125.0 1 226.3 34 0.0 0.0 -1 226.2

131 Persons Load 412.0 4 041.7 131 4 041.7 0.0 0.0


132 Weight of gas and liquid in the pipe 40.0 392.4 132 392.4 0.0 0.0
133 Stored liquid and goods 80.0 784.8 133 784.8 0.0 0.0
134 Layout Area 125.0 1 226.3 134 1 226.2 0.0 0.0

231 Persons Load 412.0 4 041.7 231 0.0 4 041.7 0.0


232 Weight of gas and liquid in the pipe 40.0 392.4 232 0.0 392.4 0.0
233 Stored liquid and goods 80.0 784.8 233 0.0 784.8 0.0
234 Layout Area 125.0 1 226.3 234 0.0 1 226.2 0.0
Figure D-4 Basic Load SESTRA 100

BASIC LIVE LOAD SESTRA 150

WEIGHT REPORT SESTRA 150


LC DESCRIPTIONS X Y Z LC X Y Z
Z Direction kN kN
31 Persons Load 0.0 0.0 4 041.7
32 Weight of gas and liquid in the pipe 0.0 0.0 392.4
33 Stored liquides and goods (Tanks) 0.0 0.0 784.8
34 Laydown area 0.0 0.0 1 226.3
6 445.2 1 0.0 0.0 -6 445.2

X Direction
131 Persons Load 4 041.7 0.0 0.0
132 Weight of gas and liquid in the pipe 392.4 0.0 0.0
133 Stored liquides and goods (Tanks) 784.8 0.0 0.0
134 Laydown area 1 226.3 0.0 0.0
6 445.2 2 6 445.2 0.0 0.0

Y Direction
231 Persons Load 0.0 4 041.7 0.0
232 Weight of gas and liquid in the pipe 0.0 392.4 0.0
233 Stored liquides and goods (Tanks) 0.0 784.8 0.0
234 Laydown area 0.0 1 226.3 0.0
6 445.2 3 0.0 6 445.2 0.0
Figure D-5 Basic Live load SESTRA 150

57
INPLACE LOAD COMBINATIONS, PRESEL

Self generated dead weight


BLC SEL. 10

Surface protection
Secondary steel

Outfitting steel

Architectural
Load-Name

Instrument
Equipment

Electrical

Safety
Piping

HVAC
-z 1 2 3 20 21 22 23 24 25 26 27
+x 101 120 123 126
+y 201 220 223 226
1 1.0
2 1.0
3 1.0
20 1.0
21 1.0
-z 22 1.0
23 1.0
24 1.0
25 1.0
26 1.0
Intermediate Level comb. SEL. 100

27 1.0
101 1.0
102 1.0
103 1.0
120 1.0
121 1.0
+x 122 1.0
123 1.0
124 1.0
125 1.0
126 1.0
127 1.0
201 1.0
202 1.0
203 1.0
220 1.0
221 1.0
+y 222 1.0
223 1.0
224 1.0
225 1.0
226 1.0
227 1.0
Figure D-6 Presel load combination, static loads, run 1

Note. Static load cases are the same for Inplace and Transport conditions

58
Self generated dead weight
BLC SEL. 100

Surface protection
Secondary steel

Outfitting steel

Architectural
Load-Name

Instrument
Equipment

Electrical

Safety
Piping

HVAC
-z 1 2 3 20 21 22 23 24 25 26 27
+x 101 102 103 120 121 122 123 124 125 126 127
+y 201 202 203 220 221 222 223 224 225 226 227
1 1.1 1.1 1.1
-z
Intermediate Level
comb. SEL. 150

2 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1


11 1.1 1.1 1.1
+x
12 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1
21 1.1 1.1 1.1
+y
22 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1
Figure D-7 Presel load combination, static loads, run 2
Structural dead weights

Equipment dead load


BLC SEL. 150

Load-Name

-z 1 2
+x 11 12

+y 21 22
Intermediate Level

-z 397 1.0 1.0


comb. SEL. 200

+x 398 1.0 1.0

+y 399 1.0 1.0

Figure D-8 Presel load combination, static loads, run 3

59
Self generated dead weight

Stored liquides and goods


weight of gas and liquid
Surface protection

Wind from West


Secondary steel

Wind from East


Outfitting steel
BLC SEL. 10

Laydown area
Architectural

Persons load
Load-name

Instrument
Equipment

Electrical

Safety
Piping

HVAC
-z 1 2 3 20 21 22 23 24 25 26 27 31 32 33 34
+x 2 102 103 120 121 122 123 124 125 126 127 131 132 133 134 50 51
+y 3 202 203 220 221 222 223 224 225 226 227 231 232 233 234
1 1.0
2 1.0
3 1.0
20 1.0
21 1.0
22 1.0
23 1.0
-z 24 1.0
25 1.0
26 1.0
27 1.0
31 1.0
32 1.0
33 1.0
34 1.0
101 1.0
102 1.0
Intermediate Level comb. SEL. 100

103 1.0
120 1.0
121 1.0
122 1.0
123 1.0
124 1.0
+x 125 1.0
126 1.0
127 1.0
131 1.0
132 1.0
133 1.0
134 1.0
50 1.0
51 1.0
201 1.0
202 1.0
203 1.0
220 1.0
221 1.0
222 1.0
223 1.0
+y 224 1.0
225 1.0
226 1.0
227 1.0
231 1.0
232 1.0
233 1.0
234 1.0

Figure D-9 Presel load combination, live loads, run 1

60
Self generated dead weight

Stored liquides and goods


weight of gas and liquid
BLC SEL. 100

Surface protection

Wind from West


Secondary steel

Wind from East


Outfitting steel

Laydown area
Architectural

Persons load
Load-name

Instrument
Equipment

Electrical

Safety
Piping

HVAC
-z 1 2 3 20 21 22 23 24 25 26 27 31 32 33 34
+x 101 102 103 120 121 122 123 124 125 126 127 131 132 133 134 50 51
+y 201 202 203 220 221 222 223 224 225 226 227 231 232 233 234
Intermediate Level comb.

1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1
-z
31 1.0 1.0 1.0 1.0
2 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1
SEL. 150

32 1.0 1.0 1.0 1.0


+x
50 1.0
51 1.0
3 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1
+y
33 1.0 1.0 1.0 1.0
Figure D-10 Presel load combination, live loads, run 2
Wind from West

Wind from East


BLC SEL. 150

Load-Name

Dead

Live

-z 1 31 50 51
+x 2 32
+y 3 33
Intermediate Level comb. SEL. 197

101 0.020 0.020


-z 31 1.000
201 0.061 0.061
102 0.051
202 0.245 0.245
+x 32 0.510
150 1.000
151 1.000
103 0.051
+y 203 0.255 0.255
33 0.510
Figure D-11 Presel load combination, live loads, run 3

61
Intermediate Level comb.
BLC SEL. 11
SEL. 100
BLC SEL. 100

-z
Direction

comb. SEL. 150


Intermediate Level
Load-Name

27
26
25
24
23
22
21
20
3
2
1

-z
1
Self generated dead weight

1.0
Load-Name

2
1
2
Secondary steel

1.0

1
Self generated dead weight

1.1
3
Outfitting steel

2
1.0
Secondary steel

1.1
20

Equipment

3
Outfitting steel
1.0

1.1
LIFTING LOAD COMBINATIONS, PRESEL

21

20
Equipment 1.0 Electrical

1.1
21
Electrical
22

Instrument

1.1
1.0

22
Instrument
23

1.1
Piping
1.0

23
Piping

1.1
24

HVAC
1.0

24
HVAC

Figure D-13 Presel load combination, static loads, run 2


Figure D-12 Presel load combination, static loads, run 1

1.1
25

Safety
1.0

25
Safety

1.1
26

Surface protection
1.0

26
Surface protection

1.1
27

Architectural

27
Architectural
1.0

1.1

62
Structural dead weights

Equipment dead load


BLC SEL. 150

Load-Name
Direction
1 2
Intermediate Level comb.
-z 397 1.0 1.0
SEL. 200
Figure D-14 Presel load combination, static loads, run 3
BLC SEL. 200

Load-Name

Dead load
Direction

397
-z 1 2.808
Top Level comb. SEL. 201
-z 2 3.174
Figure D-15 Presel load combination, static loads, run 4

63
TRANSPORT LOAD COMBINATION, PRESEL

Self generated dead weight

Stored liquides and goods


weight of gas and liquid
Surface protection

Wind from South

Wind from North


Wind from West
Secondary steel

Wind from East


Outfitting steel
BLC SEL. 10

Laydown area
Architectural

Persons load
Load-name

Instrument
Equipment

Electrical

Safety
Piping

HVAC
-z 1 2 3 20 21 22 23 24 25 26 27 31 32 33 34
+x 2 102 103 120 121 122 123 124 125 126 127 131 132 133 134 52 53 54 55
+y 3 202 203 220 221 222 223 224 225 226 227 231 232 233 234
1 1.0
2 1.0
3 1.0
20 1.0
21 1.0
22 1.0
23 1.0
-z 24 1.0
25 1.0
26 1.0
27 1.0
31 1.0
32 1.0
33 1.0
34 1.0
101 1.0
102 1.0
103 1.0
Intermediate Level comb. SEL. 100

120 1.0
121 1.0
122 1.0
123 1.0
124 1.0
125 1.0
+x 126 1.0
127 1.0
131 1.0
132 1.0
133 1.0
134 1.0
52 1.0
53 1.0
54 1.0
55 1.0
201 1.0
202 1.0
203 1.0
220 1.0
221 1.0
222 1.0
223 1.0
+y 224 1.0
225 1.0
226 1.0
227 1.0
231 1.0
232 1.0
233 1.0
234 1.0

Figure D-16 Presel load combination, live loads, run 1

64
Self generated dead weight
BLC SEL. 100

Surface protection

Wind from West


Secondary steel

Wind from East

Wind from East

Wind from East


Outfitting steel

Architectural
Load-name

Instrument
Equipment

Electrical

Safety
Piping

HVAC
-z 1 2 3 20 21 22 23 24 25 26 27
+x 101 102 103 120 121 122 123 124 125 126 127 52 53 54 55
+y 201 202 203 220 221 222 223 224 225 226 227
1 1.100 1.100 1.100
2 1.100 1.100 1.100 1.100 1.100 1.100 1.100 1.100
+y
101 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200 0.200
104 -0.200 -0.200 -0.200 -0.200 -0.200 -0.200 -0.200 -0.200 -0.200 -0.200 -0.200
Intermediate Level comb. SEL. 150

11 1.100 1.100 1.100


+x 12 1.100 1.100 1.100 1.100 1.100 1.100 1.100 1.100
102 1.054 1.054 1.054 1.054 1.054 1.054 1.054 1.054 1.054 1.054 1.054
152 1.000
153 0.707 0.707
154 1.000
155 0.707 0.707
156 1.000
157 0.707 0.707
158 1.000
159 0.71 0.707

21 1.100 1.100 1.100


+y 22 1.100 1.100 1.100 1.100 1.100 1.100 1.100 1.100
103 0.530 0.530 0.530 0.530 0.530 0.530 0.530 0.530 0.530 0.530 0.530
Figure D-17 Presel load combination, live loads, run 2

65
Self generated weight

Equipment dead load

Barge acceleration

Barge acceleration

Barge acceleration

Barge acceleration
BLC SEL. 150

Load-Name

Wind

Wind

Wind

Wind

Wind

Wind

Wind

Wind
-z 1 2 101 104
+x 11 12 102 152 153 154 155 156 157 158 159
+y 21 22 103
-z 1 1.000 1.000
2 1.000 1.000
52 1.000
53 1.000
54 1.000
Intermediate Level comb. SEL. 197

+x 55 1.000
56 1.000
57 1.000
58 1.000
59 1.000
+y 3 1.000 1.000
201 1.000
202 1.000
203 0.707 0.707
204 1.000
205 -0.707 0.707
206 -1.000
207 -0.707 -0.707
208 -1.000
209 0.707 -0.707
210 1.000

Figure D-18 Presel load combination, live loads, run 3

66
PREPOST LOAD COMBINATIONS, INPLACE

LOAD COMBINATIONS

Earthquake load 10^-2 (X)

Earthquake load 10^-2 (Y)

Earthquake load 10^-4 (X)

Earthquake load 10^-4 (Y)


Earthquake load 10^-2 (Z)

Earthquake load 10^-4 (Z)


Wind load (+X)

Wind load (-X)


Dead Load (-Z)

Live Load (-Z)


LOAD CASE

397 31 150 151 101 102 103 201 202 203


501 1.3 1.3 0.7
502 1.3 1.3 0.7
521 1.3 1.3 1.3 1.3
ULS a

523 1.3 1.3 1.3 1.3


525 1.3 1.3 0.7 0.495 0.495
527 1.3 1.3 0.7 -0.495 0.495
529 1.3 1.3 0.7 -0.495 -0.495
531 1.3 1.3 0.7 0.495 -0.495

503 1.0 1.0 1.3


504 1.0 1.0 1.3
522 1.0 1.0 1.3 1.3
ULS b

524 1.0 1.0 1.3 1.3


526 1.0 1.0 1.3 0.919 0.919
528 1.0 1.0 1.3 0.919 0.919
530 1.0 1.0 1.3 -0.919 -0.919
532 1.0 1.0 1.3 0.919 -0.919

541 1.0 1.0 1.0 1.0


542 1.0 1.0 1.0 0.707 0.707
ALS

543 1.0 1.0 1.0 1.0


544 1.0 1.0 1.0 -0.707 0.707
545 1.0 1.0 1.0 -0.707 -0.707
546 1.0 1.0 1.0 0.707 -0.707
Figure D-19 Prepost load combination, inplace

67
LOAD COMBINATION

LOAD COMBINATIONS

Dead Load (-Z)


Load Name

397
1 2.808
ULS a 2 3.174
Figure D-20 Load combination lift

68
PREPOST LOAD COMBINATIONS, TRANSPORT

LOAD COMBINATIONS

Barge acceleration (+X+Y)

Barge acceleration (-X+Y)

Barge acceleration (+X-Y)


Barge acceleration (-X-Y)
Barge acceleration (+X)

Barge acceleration (+Y)

Barge acceleration (-X)


Barge acceleration (-Z)

Barge acceleration (-Z)


Wind load (-X+Y)

Wind load (-X+Y)

Wind load (+X-Y)


Wind load (-X-Y)
Wind load (+X)

Wind load (+Y)

Wind load (-X)

Wind load (-Y)


Dead Load (-Z)

Live Load (-Z)


LOAD CASE

397 52 53 54 55 56 57 58 59 201 202 203 204 205 206 207 208 209 210
601 1.3 0.7 1.3 1.3
603 1.3 0.7 1.3 1.3
605 1.3 0.7 1.3 1.3
607 1.3 0.7 1.3 1.3
609 1.3 0.7 1.3 1.3
611 1.3 0.7 1.3 1.3
613 1.3 0.7 1.3 1.3
ULS a

615 1.3 0.7 1.3 1.3


617 1.3 0.7 1.3 1.3
619 1.3 0.7 1.3 1.3
621 1.3 0.7 1.3 1.3
623 1.3 0.7 1.3 1.3
625 1.3 0.7 1.3 1.3
627 1.3 0.7 1.3 1.3
629 1.3 0.7 1.3 1.3
631 1.3 0.7 1.3 1.3

602 1.0 1.3 1.0 1.0


604 1.0 1.3 1.0 1.0
606 1.0 1.3 1.0 1.0
608 1.0 1.3 1.0 1.0
610 1.0 1.3 1.0 1.0
612 1.0 1.3 1.0 1.0
614 1.0 1.3 1.0 1.0
ULS b

616 1.0 1.3 1.0 1.0


618 1.0 1.3 1.0 1.0
620 1.0 1.3 1.0 1.0
622 1.0 1.3 1.0 1.0
624 1.0 1.3 1.0 1.0
626 1.0 1.3 1.0 1.0
628 1.0 1.3 1.0 1.0
630 1.0 1.3 1.0 1.0
532 1.0 1.3 1.0 1.0
Figure D-21 Prepost load combination, transport

69
WIND LOAD CALCULATION

70
71
72
73
74
75
BARGE ACCELERATION

76
77
COG ENVELOPE

Input SESTRA listing


LOADCASE X-LOAD Y-LOAD Z-LOAD X-MOM Y-MOM Z-MOM X-RMOM Y-RMOM Z-RMOM

397 1.46E-17 -1.19E-18 -1.73E+01 2.52E-01 0.00E+00 0.00E+00 -1.74E+02 3.46E+02 -1.69E-16
398 1.73E+01 0.00E+00 1.66E-10 -1.01E-03 -1.81E-04 3.89E-01 5.19E-10 1.61E+02 -1.74E+02
399 0.00E+00 1.73E+01 -2.30E-08 -3.31E-01 1.26E-22 -5.96E-19 -1.61E+02 4.32E-07 3.45E+02
Figure D-22 SESTRA output

CoG check
FROM SESTRA LISTING

[KiloNewton] [MegaNewton*Meter] CoG (Local Coord.) Weight (T)


X-LOAD Y-LOAD Z-LOAD X-RMOM Y-RMOM Z-RMOM X Y Z
AccelerationLoadCase
-Z 397 0.0 0.0 17,300.0 174.0 346.0 0.0 20.001 10.060 1763.5

x 398 17,300.0 0.0 0.0 0.0 160.7 174.0 10.060 9.288 1763.5

y 399 0.0 17,300.0 0.0 160.7 0.0 345.1 19.947 9.288 1763.5

Weight x y
Length between support points 20.000 20.000
Geometric middle 20.000 10.000 10.000
CoG, "as is" analysis 1,603.2 19.974 10.060 9.288

Δx Δy
0.026 0.060

CoG shift = ((Lx+Δx)/Lx)*((Ly+Δy)/Ly) 1.0043

Original weight report 3451.8 299.290 155.460 525.210

From GeniE Check


Weight Load x-cog y-cog z-cog Load x-cog y-cog z-cog
[ton] [kN] [m] [m] [m]

LC397 Self generated weight 1,763.51 1,763.5 20.001 10.060 OK OK OK

LC398 Self generated weight 1,763.51 1,763.5 10.060 9.288 OK OK OK

LC399 Self generated weight 1,763.51 1,763.5 19.947 9.288 OK OK OK

Max diff: 0.800 % 0.500 % 0.500 % 0.500 %

As of: 5/31/2012

Figure D-23 CoG calculation

78
E. GLOBAL ANALYSIS

FRAMEWORK MEMBER CHECK RESULT

 Inplace condition
 Lift condition
 Transport condition

MEMBER ASSESMENT

 Inplace condition
 Lift condition
 Transport condition

79
FRAMEWORK MEMBER CHECK RESULT, INPLACE
****** ****** ****** ****** ** *** ****
******** ******** ******** ******** *************
** ** ** ** ** ** ** ** ** ** **
** ** ** ** ** ** ** **
******* ********** ******* ********* ** ** **
******* ********* ******* ********** ** ** **
** ** ** ** ** ** ** **
** ** ** ** ** ** ** ** ** ** **
******** ******** ******** ********* ** ** **
****** ****** ****** ****** ** ** ** **

*********************************************************************************************
*********************************************************************************************
** **
** **
** ******* ****** ***** * * ******* * * ***** ****** * * **
** * * * * * ** ** * * * * * * * * * **
** * * * * * * * * * * * * * * * * * * **
** ***** ****** ******* * * * ***** * * * * * ****** *** **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * ******* ** ** ***** * * * * **
** **
** **
** Postprocessing of Frame Structures **
** **
** **
*********************************************************************************************
*********************************************************************************************

Marketing and Support by DNV Software

Program id : 3.6-02 Computer : 586


Release date : 7-JUN-2011 Impl. update :
Access time : 12-JUN-2012 09:17:05 Operating system : Win NT 6.1 [7601]
User id : 123333 CPU id : 0476028815
Installation : , EURW120334

DATE: 12-JUN-2012 TIME: 09:17:05 PROGRAM: SESAM FRAMEWORK 3.6-02 7-JUN-2011 PAGE:
1

MEMBER check: EC3/NS3472 ENV 1993-1-1/Ed 3


Run: Superelement: Loadset:
ULS T197 INPLACE
Priority....: Worst Loadcase
Usage factor: Above 0.50 SUB PAGE:
1

NOMENCLATURE:

Member Name of member


LoadCase Name of loadcase
CND Operational, storm or earthquake condition
Type Section type
Joint/Po Joint name or position within the member
Outcome Outcome message from the code check
UsfTot Total usage factor: UsfTot = UsfAx + UsfMy + UsfMz
UsfAx Usage factor due to axial stress
N Acting axial force
Ndy(Nkdy) Axial (buckling) force capacity about y-axis
My*ky Design bending moment used for bending about y-axis
Mdy Moment capacity for bending about y-axis
Ky Effective length factor for bending about y-axis
Ly Buckling length for bending about y-axis
Phase Phase angle in degrees
SctNam Section name
EleNum Element number
UsfMy Usage factor due to bending about y-axis
Fy Yield strength
Ndz(Nkdy) Axial (buckling) force capacity about z-axis
Mz*kz Design bending moment used for bending about z-axis
Mdz Moment capacity for bending about z-axis
Kz Effective length factor for bending about z-axis
Lz Buckling length for bending about z-axis
UsfMz Usage factor due to bending about z-axis
Gamma-m Material factor, gamma-M1
vMises Equivalent stress used in von Mises stress check
Lbuck Length between lateral support of compression flange
C1 Lateral buckling factor
BCrv y,z Buckling curve for bending about y,z-axes
Class w,f Cross section class for web, flange

80
Member LoadCase CND Type Joint/Po Outcome UsfTot UsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MY302020 543 I 0.50 *Fa StaL 1.024 0.027 -1.35E-01 1.76E+01 -3.22E+00 3.23E+00 1.000 1.00E+01
I1242035 229 0.997 4.20E+02 4.97E+00 9.71E-05 1.06E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 1

MY702020 543 I 0.50 StaL 0.994 0.027 -1.36E-01 1.76E+01 -3.12E+00 3.23E+00 1.000 1.00E+01
I1242035 371 0.965 4.20E+02 4.97E+00 -1.02E-03 1.06E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 1

MY301020 545 I 0.50 StaL 0.934 0.018 -8.77E-02 1.76E+01 -2.91E+00 3.23E+00 1.000 1.00E+01
I1242035 221 0.902 4.20E+02 4.97E+00 1.53E-02 1.06E+00 1.000 1.00E+01
0.014 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 1

MY701020 546 I 0.50 StaL 0.925 0.015 -7.39E-02 1.76E+01 -2.87E+00 3.23E+00 1.000 1.00E+01
I1242035 363 0.889 4.20E+02 4.97E+00 -2.27E-02 1.06E+00 1.000 1.00E+01
0.021 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 1

MY702010 543 I 0.50 StaL 0.885 0.073 -6.23E-01 2.01E+01 -3.84E+00 4.75E+00 1.000 1.00E+01
I1252035 369 0.808 4.20E+02 8.50E+00 -3.34E-03 1.07E+00 1.000 1.00E+01
0.003 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MY302010 543 I 0.50 StaL 0.883 0.078 -6.63E-01 2.01E+01 -3.82E+00 4.75E+00 1.000 1.00E+01
I1252035 227 0.804 4.20E+02 8.50E+00 1.20E-03 1.07E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MY301010 545 I 0.50 StaL 0.782 0.061 -5.19E-01 2.01E+01 -3.19E+00 4.75E+00 1.000 1.00E+01
I1252035 219 0.671 4.20E+02 8.50E+00 5.32E-02 1.07E+00 1.000 1.00E+01
0.050 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MY701010 546 I 0.50 StaL 0.779 0.057 -4.85E-01 2.01E+01 -3.20E+00 4.75E+00 1.000 1.00E+01
I1252035 361 0.674 4.20E+02 8.50E+00 -5.14E-02 1.07E+00 1.000 1.00E+01
0.048 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MZ304010 544 BOX 0.50 Stab 0.665 0.274 -7.98E+00 2.91E+01 -2.18E+00 6.88E+00 1.000 6.70E+00
B060640 234 0.316 4.20E+02 2.91E+01 5.11E-01 6.88E+00 1.000 6.70E+00
0.074 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY302030 527 I 0.50 Lbck 0.661 0.000 1.24E-01 1.81E+01 2.23E+00 3.38E+00 1.000 1.00E+01
I0852035 231 0.659 4.20E+02 1.81E+01 -3.50E-03 1.62E+00 1.000 1.00E+01
0.002 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MF104010 543 BOX 0.50 Stab 0.660 0.333 -2.39E+00 7.20E+00 3.41E-01 1.34E+00 1.000 7.49E+00
B040420 160 0.255 3.55E+02 7.20E+00 9.70E-02 1.34E+00 1.000 7.49E+00
0.072 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MF902520 543 BOX 0.50 Stab 0.660 0.272 -1.96E+00 7.20E+00 4.59E-01 1.34E+00 1.000 7.49E+00
B040420 450 0.343 3.55E+02 7.20E+00 5.97E-02 1.34E+00 1.000 7.49E+00
0.045 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MY302040 529 I 0.50 StaL 0.640 0.031 -2.50E-01 1.61E+01 -2.04E+00 3.38E+00 1.000 1.00E+01
I0852035 232 0.602 4.20E+02 8.09E+00 1.11E-02 1.62E+00 1.000 1.00E+01
0.007 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MZ301010 545 BOX 0.50 Stab 0.637 0.253 -7.36E+00 2.91E+01 2.14E+00 6.88E+00 1.000 6.70E+00
B060640 216 0.311 4.20E+02 2.91E+01 4.99E-01 6.88E+00 1.000 6.70E+00
0.072 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY701030 531 I 0.33 StaL 0.624 0.001 -5.37E-03 1.61E+01 -2.11E+00 3.38E+00 1.000 1.00E+01
I0852035 365 0.623 4.20E+02 8.09E+00 -5.68E-04 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MX204010 542 I 0.50 StaL 0.618 0.141 -1.68E+00 1.85E+01 -2.43E+00 5.44E+00 1.000 5.00E+00
I1242035 208 0.446 4.20E+02 1.19E+01 2.05E-02 6.83E-01 1.000 5.00E+00
0.030 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MY702030 525 I 0.50 Lbck 0.613 0.000 1.21E-03 1.81E+01 2.07E+00 3.38E+00 1.000 1.00E+01
I0852035 373 0.612 4.20E+02 1.81E+01 -2.13E-03 1.62E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MZ704010 542 BOX 0.50 Stab 0.612 0.228 -6.64E+00 2.91E+01 -2.09E+00 6.88E+00 1.000 6.70E+00
B060640 376 0.304 4.20E+02 2.91E+01 -5.48E-01 6.88E+00 1.000 6.70E+00
0.080 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MX201010 546 I 0.50 StaL 0.610 0.138 -1.64E+00 1.85E+01 -2.39E+00 5.44E+00 1.000 5.00E+00
I1242035 200 0.439 4.20E+02 1.19E+01 -2.25E-02 6.83E-01 1.000 5.00E+00
0.033 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MZ701010 546 BOX 0.50 Stab 0.609 0.230 -6.70E+00 2.91E+01 2.05E+00 6.88E+00 1.000 6.70E+00
B060640 358 0.298 4.20E+02 2.91E+01 -5.57E-01 6.88E+00 1.000 6.70E+00
0.081 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY301030 529 I 0.33 Lbck 0.607 0.000 4.89E-02 1.81E+01 2.05E+00 3.38E+00 1.000 1.00E+01
I0852035 223 0.606 4.20E+02 1.81E+01 1.01E-03 1.62E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY102040 545 I 0.50 StaL 0.603 0.165 -3.45E-01 9.04E+00 2.80E-01 1.17E+00 1.000 1.00E+01
HE800B 158 0.240 3.55E+02 2.09E+00 9.39E-02 4.76E-01 1.000 1.00E+01
0.197 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 1

81
4

Member LoadCase CND Type Joint/Po Outcome UsfTot UsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
ME101320 546 BOX 0.50 Stab 0.583 0.280 -2.01E+00 7.20E+00 2.89E-01 1.34E+00 1.000 7.49E+00
B040420 141 0.216 3.55E+02 7.20E+00 1.17E-01 1.34E+00 1.000 7.49E+00
0.088 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MY301040 529 I 0.50 StaL 0.576 0.013 -1.09E-01 1.61E+01 1.89E+00 3.38E+00 1.000 1.00E+01
I0852035 226 0.560 4.20E+02 8.09E+00 4.61E-03 1.62E+00 1.000 1.00E+01
0.003 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MX604010 541 I 0.50 StaL 0.569 0.087 -1.03E+00 1.85E+01 -2.46E+00 5.44E+00 1.000 5.00E+00
I1242035 350 0.452 4.20E+02 1.19E+01 2.06E-02 6.83E-01 1.000 5.00E+00
0.030 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX601010 541 I 0.50 StaL 0.565 0.084 -9.99E-01 1.85E+01 -2.44E+00 5.44E+00 1.000 5.00E+00
I1242035 342 0.449 4.20E+02 1.19E+01 2.22E-02 6.83E-01 1.000 5.00E+00
0.032 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX704010 544 I 0.50 StaL 0.564 0.125 -1.49E+00 1.85E+01 -2.21E+00 5.44E+00 1.000 5.00E+00
I1242035 391 0.405 4.20E+02 1.19E+01 2.29E-02 6.83E-01 1.000 5.00E+00
0.034 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX701010 545 I 0.50 StaL 0.562 0.123 -1.47E+00 1.85E+01 -2.20E+00 5.44E+00 1.000 5.00E+00
I1242035 383 0.404 4.20E+02 1.19E+01 -2.42E-02 6.83E-01 1.000 5.00E+00
0.035 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

ME901010 545 BOX 0.50 Stab 0.561 0.204 -1.46E+00 7.20E+00 3.89E-01 1.34E+00 1.000 7.49E+00
B040420 432 0.291 3.55E+02 7.20E+00 8.92E-02 1.34E+00 1.000 7.49E+00
0.067 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MX602010 521 I 0.50 StaL 0.560 0.028 -1.56E-01 1.01E+01 -1.10E+00 2.07E+00 1.000 5.00E+00
HE800B 345 0.532 3.55E+02 5.62E+00 -6.02E-05 4.76E-01 1.000 5.00E+00
0.000 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MY102010 501 I 0.50 Lbck 0.557 0.000 4.56E-01 1.01E+01 5.71E-01 1.17E+00 1.000 1.00E+01
HE800B 157 0.488 3.55E+02 1.01E+01 -3.26E-02 4.76E-01 1.000 1.00E+01
0.068 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 1

MY101010 501 I 0.50 Lbck 0.552 0.000 4.83E-01 1.01E+01 5.66E-01 1.17E+00 1.000 1.00E+01
HE800B 146 0.484 3.55E+02 1.01E+01 -3.24E-02 4.76E-01 1.000 1.00E+01
0.068 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 1

MY502020 527 I 0.50 StaL 0.547 0.006 -4.85E-02 2.01E+01 2.70E+00 5.01E+00 1.000 1.00E+01
I1252035 300 0.539 4.20E+02 8.50E+00 3.50E-03 1.64E+00 1.000 1.00E+01
0.002 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

MX702010 525 I 0.50 StaL 0.547 0.008 -4.35E-02 1.01E+01 -1.11E+00 2.07E+00 1.000 5.00E+00
HE800B 386 0.535 3.55E+02 5.62E+00 1.88E-03 4.76E-01 1.000 5.00E+00
0.004 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MY501020 529 I 0.50 StaL 0.544 0.002 -1.80E-02 2.01E+01 2.70E+00 5.01E+00 1.000 1.00E+01
I1252035 292 0.539 4.20E+02 8.50E+00 3.69E-03 1.64E+00 1.000 1.00E+01
0.002 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

MZ504010 544 BOX 0.50 Stab 0.542 0.084 -1.33E+00 1.60E+01 -1.05E+00 2.85E+00 1.000 6.70E+00
B040440 304 0.370 4.20E+02 1.60E+01 -2.54E-01 2.85E+00 1.000 6.70E+00
0.089 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MZ501010 545 BOX 0.50 Stab 0.536 0.081 -1.30E+00 1.60E+01 1.05E+00 2.85E+00 1.000 6.70E+00
B040440 287 0.367 4.20E+02 1.60E+01 -2.50E-01 2.85E+00 1.000 6.70E+00
0.088 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MF102530 543 BOX 0.50 Stab 0.533 0.192 -1.39E+00 7.25E+00 1.73E-01 1.34E+00 1.000 7.38E+00
B040420 154 0.129 3.55E+02 7.25E+00 2.83E-01 1.34E+00 1.000 7.38E+00
0.211 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MX304010 544 I 0.50 StaL 0.520 0.094 -1.12E+00 1.85E+01 -2.14E+00 5.44E+00 1.000 5.00E+00
I1242035 249 0.393 4.20E+02 1.19E+01 2.25E-02 6.83E-01 1.000 5.00E+00
0.033 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MY102020 543 I 0.50 StaL 0.516 0.037 -1.47E-01 9.74E+00 -7.94E-01 1.69E+00 1.000 6.65E+00
HE800B 155 0.471 3.55E+02 3.97E+00 4.11E-03 4.76E-01 1.000 6.65E+00
0.009 1.150 0.00E+00 6.65E+00 1.000 C , C 1 , 1

MX301010 545 I 0.50 StaL 0.514 0.094 -1.12E+00 1.85E+01 -2.10E+00 5.44E+00 1.000 5.00E+00
I1242035 241 0.386 4.20E+02 1.19E+01 -2.29E-02 6.83E-01 1.000 5.00E+00
0.033 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX604020 541 I 0.50 StaL 0.508 0.013 -7.34E-02 1.01E+01 -9.95E-01 2.07E+00 1.000 5.00E+00
HE800B 351 0.482 3.55E+02 5.62E+00 6.22E-03 4.76E-01 1.000 5.00E+00
0.013 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MX601020 541 I 0.50 StaL 0.505 0.013 -7.19E-02 1.01E+01 -9.93E-01 2.07E+00 1.000 5.00E+00
HE800B 343 0.480 3.55E+02 5.62E+00 -5.47E-03 4.76E-01 1.000 5.00E+00
0.012 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MX302010 529 I 0.50 StaL 0.502 0.029 -1.63E-01 1.01E+01 -9.75E-01 2.07E+00 1.000 5.00E+00
HE800B 244 0.472 3.55E+02 5.62E+00 -7.00E-04 4.76E-01 1.000 5.00E+00
0.001 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

82
FRAMEWORK MEMBER CHECK LIFT MEMBERS
****** ****** ****** ****** ** *** ****
******** ******** ******** ******** *************
** ** ** ** ** ** ** ** ** ** **
** ** ** ** ** ** ** **
******* ********** ******* ********* ** ** **
******* ********* ******* ********** ** ** **
** ** ** ** ** ** ** **
** ** ** ** ** ** ** ** ** ** **
******** ******** ******** ********* ** ** **
****** ****** ****** ****** ** ** ** **

*********************************************************************************************
*********************************************************************************************
** **
** **
** ******* ****** ***** * * ******* * * ***** ****** * * **
** * * * * * ** ** * * * * * * * * * **
** * * * * * * * * * * * * * * * * * * **
** ***** ****** ******* * * * ***** * * * * * ****** *** **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * ******* ** ** ***** * * * * **
** **
** **
** Postprocessing of Frame Structures **
** **
** **
*********************************************************************************************
*********************************************************************************************

Marketing and Support by DNV Software

Program id : 3.6-02 Computer : 586


Release date : 7-JUN-2011 Impl. update :
Access time : 12-JUN-2012 09:22:13 Operating system : Win NT 6.1 [7601]
User id : 123333 CPU id : 0476028815
Installation : , EURW120334

Copyright DET NORSKE VERITAS AS, P.O.Box 300, N-1322 Hovik, Norway

DATE: 12-JUN-2012 TIME: 09:22:13 PROGRAM: SESAM FRAMEWORK 3.6-02 7-JUN-2011 PAGE:
1

MEMBER check: EC3/NS3472 ENV 1993-1-1/Ed 3


Run: Superelement: Loadset:
LIFT_1 T201 LIFT
Priority....: Worst Loadcase
Usage factor: Above 0.05 SUB PAGE:

NOMENCLATURE:

Member Name of member


LoadCase Name of loadcase
CND Operational, storm or earthquake condition
Type Section type
Joint/Po Joint name or position within the member
Outcome Outcome message from the code check
UsfTot Total usage factor: UsfTot = UsfAx + UsfMy + UsfMz
UsfAx Usage factor due to axial stress
N Acting axial force
Ndy(Nkdy) Axial (buckling) force capacity about y-axis
My*ky Design bending moment used for bending about y-axis
Mdy Moment capacity for bending about y-axis
Ky Effective length factor for bending about y-axis
Ly Buckling length for bending about y-axis
Phase Phase angle in degrees
SctNam Section name
EleNum Element number
UsfMy Usage factor due to bending about y-axis
Fy Yield strength
Ndz(Nkdy) Axial (buckling) force capacity about z-axis
Mz*kz Design bending moment used for bending about z-axis
Mdz Moment capacity for bending about z-axis
Kz Effective length factor for bending about z-axis
Lz Buckling length for bending about z-axis
UsfMz Usage factor due to bending about z-axis
Gamma-m Material factor, gamma-M1
vMises Equivalent stress used in von Mises stress check
Lbuck Length between lateral support of compression flange
C1 Lateral buckling factor
BCrv y,z Buckling curve for bending about y,z-axes
Class w,f Cross section class for web, flange
DATE: 12-JUN-2012 TIME: 09:22:13 PROGRAM: SESAM FRAMEWORK 3.6-02 7-JUN-2011 PAGE:
MEMBER check: EC3/NS3472 ENV 1993-1-1/Ed 3
Run: Superelement: Loadset:
LIFT_1 T201 LIFT
Priority....: Worst Loadcase
Usage factor: Above 0.05 SUB PAGE:

83
Member LoadCase CND Type Joint/Po Outcome UsfTotUsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MY302030 1 I 0.45 *Fa Lbck 1.014 0.000 8.07E-02 1.81E+01 3.43E+00 3.38E+00 1.000 1.00E+01
I0852035 3644 1.014 4.20E+02 1.81E+01 -4.54E-04 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY301030 1 I 0.45 Lbck 0.914 0.000 6.72E-02 1.81E+01 3.09E+00 3.38E+00 1.000 1.00E+01
I0852035 3601 0.914 4.20E+02 1.81E+01 -1.10E-03 1.62E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY501020 1 I 0.45 StaL 0.909 0.119 -1.01E+00 2.01E+01 3.75E+00 4.75E+00 1.000 1.00E+01
I1252035 3901 0.789 4.20E+02 8.50E+00 -5.78E-05 1.07E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MY701030 1 I 0.45 Lbck 0.887 0.000 9.11E-02 1.81E+01 3.00E+00 3.38E+00 1.000 1.00E+01
I0852035 4222 0.887 4.20E+02 1.81E+01 5.44E-04 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY702030 1 I 0.45 Lbck 0.863 0.000 1.08E-01 1.81E+01 2.92E+00 3.38E+00 1.000 1.00E+01
I0852035 4265 0.862 4.20E+02 1.81E+01 5.25E-04 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY302040 1 I 0.50 StaL 0.845 0.248 -2.00E+00 1.61E+01 -1.84E+00 3.20E+00 1.000 1.00E+01
I0852035 3655 0.575 4.20E+02 8.09E+00 2.42E-02 1.07E+00 1.000 1.00E+01
0.023 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MY301040 1 I 0.50 StaL 0.810 0.214 -1.73E+00 1.61E+01 -1.83E+00 3.20E+00 1.000 1.00E+01
I0852035 3612 0.572 4.20E+02 8.09E+00 2.53E-02 1.07E+00 1.000 1.00E+01
0.024 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MY702040 1 I 0.50 StaL 0.800 0.246 -1.99E+00 1.61E+01 1.83E+00 3.38E+00 1.000 1.00E+01
I0852035 4276 0.540 4.20E+02 8.09E+00 -2.22E-02 1.62E+00 1.000 1.00E+01
0.014 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

MY701010 1 I 0.50 Lbck 0.788 0.000 6.79E-01 2.10E+01 3.95E+00 5.01E+00 1.000 1.00E+01
I1252035 4200 0.787 4.20E+02 2.10E+01 1.77E-03 1.64E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

MY701040 1 I 0.50 StaL 0.767 0.212 -1.71E+00 1.61E+01 1.83E+00 3.38E+00 1.000 1.00E+01
I0852035 4233 0.540 4.20E+02 8.09E+00 -2.40E-02 1.62E+00 1.000 1.00E+01
0.015 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY502020 1 I 0.45 StaL 0.766 0.014 -1.21E-01 2.01E+01 3.77E+00 5.01E+00 1.000 1.00E+01
I1252035 3943 0.751 4.20E+02 8.50E+00 -2.14E-04 1.64E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

MX402010 1 I 0.40 StaL 0.765 0.031 -1.71E-01 9.42E+00 -1.35E+00 1.90E+00 1.000 5.00E+00
HE800B 3838 0.713 3.55E+02 5.44E+00 6.13E-03 3.06E-01 1.000 5.00E+00
0.020 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MY501030 1 I 0.45 Lbck 0.757 0.000 9.72E-03 1.81E+01 2.56E+00 3.38E+00 1.000 1.00E+01
I0852035 3912 0.757 4.20E+02 1.81E+01 -3.65E-04 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY502030 1 I 0.45 Lbck 0.757 0.000 1.03E-02 1.81E+01 2.56E+00 3.38E+00 1.000 1.00E+01
I0852035 3954 0.757 4.20E+02 1.81E+01 2.79E-04 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY702010 1 I 0.50 Lbck 0.745 0.000 1.25E+00 2.10E+01 3.73E+00 5.01E+00 1.000 1.00E+01
I1252035 4243 0.745 4.20E+02 2.10E+01 -3.85E-04 1.64E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MF302020 1 BOX 0.50 Stab 0.702 0.509 -2.54E+00 4.99E+00 -2.58E-01 1.34E+00 1.000 1.20E+01
B040420 3627 0.193 3.55E+02 4.99E+00 9.89E-19 1.34E+00 1.000 1.20E+01
0.000 1.150 0.00E+00 1.20E+01 0.000 C , C 1 , 1

MX502010 1 I 0.40 StaL 0.701 0.034 -1.90E-01 1.01E+01 -1.35E+00 2.07E+00 1.000 5.00E+00
HE800B 4000 0.655 3.55E+02 5.62E+00 6.09E-03 4.76E-01 1.000 5.00E+00
0.013 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MY102010 1 I 0.50 Lbck 0.690 0.000 4.95E-01 1.01E+01 7.64E-01 1.17E+00 1.000 1.00E+01
HE800B 3334 0.653 3.55E+02 1.01E+01 1.75E-02 4.76E-01 1.000 1.00E+01
0.037 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 1

MY101010 1 I 0.50 Lbck 0.685 0.000 4.92E-01 1.01E+01 7.65E-01 1.17E+00 1.000 1.00E+01
HE800B 3293 0.654 3.55E+02 1.01E+01 1.50E-02 4.76E-01 1.000 1.00E+01
0.032 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 1

MY301010 1 I 0.50 Lbck 0.684 0.000 8.03E-01 2.10E+01 3.42E+00 5.01E+00 1.000 1.00E+01
I1252035 3579 0.683 4.20E+02 2.10E+01 -1.21E-03 1.64E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

MF702020 1 BOX 0.50 Stab 0.672 0.456 -2.27E+00 4.99E+00 -2.89E-01 1.34E+00 1.000 1.20E+01
B040420 4248 0.216 3.55E+02 4.99E+00 3.32E-18 1.34E+00 1.000 1.20E+01
0.000 1.150 0.00E+00 1.20E+01 0.000 C , C 1 , 1

MX702010 1 I 0.40 StaL 0.656 0.091 -4.94E-01 9.42E+00 1.07E+00 1.90E+00 1.000 5.00E+00
HE800B 4313 0.564 3.55E+02 5.44E+00 3.91E-04 3.06E-01 1.000 5.00E+00
0.001 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

84
Member LoadCase CND Type Joint/Po Outcome UsfTot UsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MX302020 1 I 0.40 StaL 0.642 0.010 -1.50E-01 1.80E+01 -3.06E+00 4.89E+00 1.000 5.00E+00
I0852035 3697 0.626 4.20E+02 1.44E+01 9.99E-03 1.62E+00 1.000 5.00E+00
0.006 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MY302010 1 I 0.50 Lbck 0.641 0.000 1.37E+00 2.10E+01 3.21E+00 5.01E+00 1.000 1.00E+01
I1252035 3622 0.641 4.20E+02 2.10E+01 4.08E-04 1.64E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MX202020 1 I 0.40 StaL 0.638 0.008 -1.13E-01 1.80E+01 -3.05E+00 4.89E+00 1.000 5.00E+00
I0852035 3530 0.625 4.20E+02 1.44E+01 8.87E-03 1.62E+00 1.000 5.00E+00
0.005 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MZ501010 1 BOX 0.50 Stab 0.633 0.226 -3.60E+00 1.60E+01 1.14E+00 2.85E+00 1.000 6.70E+00
B040440 3882 0.399 4.20E+02 1.60E+01 2.12E-02 2.85E+00 1.000 6.70E+00
0.007 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY902010 1 I 0.50 Lbck 0.625 0.000 6.21E-01 1.81E+01 1.96E+00 3.38E+00 1.000 1.00E+01
I0852035 4548 0.578 4.20E+02 1.81E+01 -7.64E-02 1.62E+00 1.000 1.00E+01
0.047 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY901010 1 I 0.50 Lbck 0.624 0.000 6.30E-01 1.81E+01 1.95E+00 3.38E+00 1.000 1.00E+01
I0852035 4511 0.578 4.20E+02 1.81E+01 -7.51E-02 1.62E+00 1.000 1.00E+01
0.046 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY701020 1 I 0.45 StaL 0.622 0.070 -3.49E-01 1.76E+01 -1.69E+00 3.10E+00 1.000 1.00E+01
I1242035 4211 0.545 4.20E+02 4.97E+00 -4.38E-03 6.83E-01 1.000 1.00E+01
0.006 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 1

MZ504010 1 BOX 0.50 Stab 0.620 0.150 -2.39E+00 1.60E+01 -1.32E+00 2.85E+00 1.000 6.70E+00
B040440 3970 0.462 4.20E+02 1.60E+01 2.20E-02 2.85E+00 1.000 6.70E+00
0.008 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY501040 1 I 0.50 StaL 0.603 0.088 -7.13E-01 1.61E+01 1.74E+00 3.38E+00 1.000 1.00E+01
I0852035 3923 0.515 4.20E+02 8.09E+00 5.52E-05 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY301020 1 I 0.45 StaL 0.603 0.071 -3.53E-01 1.76E+01 -1.63E+00 3.10E+00 1.000 1.00E+01
I1242035 3590 0.525 4.20E+02 4.97E+00 4.31E-03 6.83E-01 1.000 1.00E+01
0.006 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 1

MX601040 1 I 0.40 StaL 0.596 0.216 -3.10E+00 1.80E+01 -1.28E+00 4.47E+00 1.000 5.00E+00
I0852035 4141 0.287 4.20E+02 1.44E+01 -9.89E-02 1.07E+00 1.000 5.00E+00

MZ504020 1 BOX 0.50 Stab 0.594 0.103 -1.65E+00 1.60E+01 1.39E+00 2.85E+00 1.000 6.70E+00
B040440 3971 0.487 4.20E+02 1.60E+01 -9.17E-03 2.85E+00 1.000 6.70E+00
0.003 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY502040 1 I 0.50 StaL 0.591 0.076 -6.17E-01 1.61E+01 1.74E+00 3.38E+00 1.000 1.00E+01
I0852035 3965 0.515 4.20E+02 8.09E+00 -5.52E-05 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MX301040 1 I 0.40 StaL 0.581 0.212 -3.04E+00 1.80E+01 -1.25E+00 4.47E+00 1.000 5.00E+00
I0852035 3687 0.280 4.20E+02 1.44E+01 -9.56E-02 1.07E+00 1.000 5.00E+00
0.090 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 2

MZ501020 1 BOX 0.50 Stab 0.578 0.099 -1.57E+00 1.60E+01 -1.36E+00 2.85E+00 1.000 6.70E+00
B040440 3883 0.477 4.20E+02 1.60E+01 -5.95E-03 2.85E+00 1.000 6.70E+00
0.002 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MX602010 1 I 0.40 StaL 0.565 0.099 -5.40E-01 9.42E+00 -8.80E-01 1.90E+00 1.000 5.00E+00
HE800B 4146 0.464 3.55E+02 5.44E+00 -5.05E-04 3.06E-01 1.000 5.00E+00
0.002 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MY401030 1 I 0.45 Lbck 0.558 0.000 2.48E-02 1.81E+01 1.89E+00 3.38E+00 1.000 1.00E+01
I0852035 3759 0.557 4.20E+02 1.81E+01 9.32E-04 1.62E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY402030 1 I 0.45 Lbck 0.548 0.000 2.69E-02 1.81E+01 1.85E+00 3.38E+00 1.000 1.00E+01
I0852035 3801 0.547 4.20E+02 1.81E+01 -5.55E-04 1.62E+00 1.000 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY801010 1 I 0.50 Lbck 0.541 0.000 4.14E-01 1.81E+01 1.82E+00 3.38E+00 1.000 1.00E+01
I0852035 4359 0.539 4.20E+02 1.81E+01 3.36E-03 1.62E+00 1.000 1.00E+01
0.002 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY302020 1 I 0.45 Lbck 0.539 0.000 3.10E-02 1.85E+01 1.74E+00 3.23E+00 1.000 1.00E+01
I1242035 3633 0.538 4.20E+02 1.85E+01 -1.37E-03 1.06E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 1

MY702020 1 I 0.45 StaL 0.536 0.007 -3.58E-02 1.76E+01 -1.70E+00 3.23E+00 1.000 1.00E+01
I1242035 4254 0.528 4.20E+02 4.97E+00 1.16E-03 1.06E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 1

MX802010 1 I 0.40 StaL 0.534 0.017 -9.63E-02 1.01E+01 1.07E+00 2.07E+00 1.000 5.00E+00
HE800B 4458 0.517 3.55E+02 5.62E+00 -1.44E-04 4.76E-01 1.000 5.00E+00
0.000 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

85
Member LoadCase CND Type Joint/Po Outcome UsfTotUsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MY802010 1 I 0.50 Lbck 0.531 0.000 3.96E-01 1.81E+01 1.79E+00 3.38E+00 1.000 1.00E+01
I0852035 4401 0.529 4.20E+02 1.81E+01 3.29E-03 1.62E+00 1.000 1.00E+01
0.002 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MX402040 1 I 0.40 StaL 0.530 0.308 -1.48E+00 7.89E+00 2.78E-01 1.25E+00 1.000 5.00E+00
HE600B 3854 0.222 3.55E+02 4.81E+00 -1.26E-04 2.78E-01 1.000 5.00E+00
0.000 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX502040 1 I 0.40 StaL 0.526 0.308 -1.48E+00 7.89E+00 2.73E-01 1.25E+00 1.000 5.00E+00
HE600B 4016 0.217 3.55E+02 4.81E+00 -1.62E-04 2.78E-01 1.000 5.00E+00
0.001 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MY402020 1 I 0.45 StaL 0.524 0.025 -2.01E-01 1.61E+01 1.68E+00 3.38E+00 1.000 1.00E+01
I0852035 3790 0.497 4.20E+02 8.09E+00 -3.05E-03 1.62E+00 1.000 1.00E+01
0.002 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MX602020 1 I 0.40 StaL 0.520 0.008 -1.08E-01 1.80E+01 -2.47E+00 4.89E+00 1.000 5.00E+00
I0852035 4151 0.506 4.20E+02 1.44E+01 1.09E-02 1.62E+00 1.000 5.00E+00
0.007 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MY601040 1 I 0.50 StaL 0.516 0.129 -1.05E+00 1.61E+01 1.29E+00 3.38E+00 1.000 1.00E+01
I0852035 4075 0.382 4.20E+02 8.09E+00 7.96E-03 1.62E+00 1.000 1.00E+01
0.005 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MX702020 1 I 0.40 StaL 0.514 0.002 -3.33E-02 1.80E+01 -2.47E+00 4.89E+00 1.000 5.00E+00
I0852035 4318 0.505 4.20E+02 1.44E+01 9.78E-03 1.62E+00 1.000 5.00E+00
0.006 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MY401040 1 I 0.50 StaL 0.513 0.128 -1.04E+00 1.61E+01 1.28E+00 3.38E+00 1.000 1.00E+01
I0852035 3770 0.379 4.20E+02 8.09E+00 -7.89E-03 1.62E+00 1.000 1.00E+01
0.005 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY601030 1 I 0.45 Lbck 0.508 0.000 2.77E-02 1.81E+01 1.72E+00 3.38E+00 1.000 1.00E+01
I0852035 4064 0.508 4.20E+02 1.81E+01 -8.36E-04 1.62E+00 1.000 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

86
FRAMEWORK MEMBERCHECK LIFT SINGLE CRITICAL MEMBER
****** ****** ****** ****** ** *** ****
******** ******** ******** ******** *************
** ** ** ** ** ** ** ** ** ** **
** ** ** ** ** ** ** **
******* ********** ******* ********* ** ** **
******* ********* ******* ********** ** ** **
** ** ** ** ** ** ** **
** ** ** ** ** ** ** ** ** ** **
******** ******** ******** ********* ** ** **
****** ****** ****** ****** ** ** ** **

*********************************************************************************************
*********************************************************************************************
** **
** **
** ******* ****** ***** * * ******* * * ***** ****** * * **
** * * * * * ** ** * * * * * * * * * **
** * * * * * * * * * * * * * * * * * * **
** ***** ****** ******* * * * ***** * * * * * ****** *** **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * ******* ** ** ***** * * * * **
** **
** **
** Postprocessing of Frame Structures **
** **
** **
*********************************************************************************************
*********************************************************************************************

Marketing and Support by DNV Software

Program id : 3.6-02 Computer : 586


Release date : 7-JUN-2011 Impl. update :
Access time : 12-JUN-2012 09:22:14 Operating system : Win NT 6.1 [7601]
User id : 123333 CPU id : 0476028815
Installation : , EURW120334

Copyright DET NORSKE VERITAS AS, P.O.Box 300, N-1322 Hovik, Norway

DATE: 12-JUN-2012 TIME: 09:22:14 PROGRAM: SESAM FRAMEWORK 3.6-02 7-JUN-2011 PAGE:

MEMBER check: EC3/NS3472 ENV 1993-1-1/Ed 3


Run: Superelement: Loadset:
LIFT_2 T201 LIFT
Priority....: Worst Loadcase
Usage factor: Above 0.05 SUB PAGE:

NOMENCLATURE:

Member Name of member


LoadCase Name of loadcase
CND Operational, storm or earthquake condition
Type Section type
Joint/Po Joint name or position within the member
Outcome Outcome message from the code check
UsfTot Total usage factor: UsfTot = UsfAx + UsfMy + UsfMz
UsfAx Usage factor due to axial stress
N Acting axial force
Ndy(Nkdy) Axial (buckling) force capacity about y-axis
My*ky Design bending moment used for bending about y-axis
Mdy Moment capacity for bending about y-axis
Ky Effective length factor for bending about y-axis
Ly Buckling length for bending about y-axis
Phase Phase angle in degrees
SctNam Section name
EleNum Element number
UsfMy Usage factor due to bending about y-axis
Fy Yield strength
Ndz(Nkdy) Axial (buckling) force capacity about z-axis
Mz*kz Design bending moment used for bending about z-axis
Mdz Moment capacity for bending about z-axis
Kz Effective length factor for bending about z-axis
Lz Buckling length for bending about z-axis
UsfMz Usage factor due to bending about z-axis
Gamma-m Material factor, gamma-M1
vMises Equivalent stress used in von Mises stress check
Lbuck Length between lateral support of compression flange
C1 Lateral buckling factor
BCrv y,z Buckling curve for bending about y,z-axes
Class w,f Cross section class for web, flange

MEMBER check: EC3/NS3472 ENV 1993-1-1/Ed 3


Run: Superelement: Loadset:
LIFT_2 T201 LIFT
Priority....: Worst Loadcase
Usage factor: Above 0.05

87
Member LoadCase CND Type Joint/Po Outcome UsfTotUsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MX601040 2 I 0.40 StaL 0.676 0.244 -3.50E+00 1.80E+01 -1.45E+00 4.47E+00 1.000 5.00E+00
I0852035 4141 0.325 4.20E+02 1.44E+01 -1.14E-01 1.07E+00 1.000 5.00E+00
0.107 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 2

MX301040 2 I 0.40 StaL 0.660 0.239 -3.44E+00 1.80E+01 -1.42E+00 4.47E+00 1.000 5.00E+00
I0852035 3687 0.317 4.20E+02 1.44E+01 -1.11E-01 1.07E+00 1.000 5.00E+00
0.104 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 2

MX304040 2 I 0.40 StaL 0.611 0.216 -3.10E+00 1.80E+01 -1.31E+00 4.47E+00 1.000 5.00E+00
I0852035 3724 0.292 4.20E+02 1.44E+01 1.10E-01 1.07E+00 1.000 5.00E+00
0.103 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 2

MX604040 2 I 0.40 StaL 0.542 0.211 -3.03E+00 1.80E+01 -1.33E+00 4.89E+00 1.000 5.00E+00
I0852035 4178 0.271 4.20E+02 1.44E+01 9.71E-02 1.62E+00 1.000 5.00E+00
0.060 1.150 0.00E+00 5.00E+00 1.000 C , C 2 , 2

MC651030 2 BOX J701040 AxLd 0.444 0.444 4.17E+00 9.38E+00 2.36E-02 1.34E+00 1.000 7.38E+00
B040420 4185 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MD301040 2 BOX J301040 AxLd 0.430 0.430 4.04E+00 9.38E+00 3.06E-02 1.34E+00 1.000 7.38E+00
B040420 3668 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MC254030 2 BOX J304040 AxLd 0.368 0.368 3.46E+00 9.38E+00 -8.17E-03 1.34E+00 1.000 7.38E+00
B040420 3569 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MC654030 2 BOX J704040 AxLd 0.359 0.359 3.37E+00 9.38E+00 -6.66E-03 1.34E+00 1.000 7.38E+00
B040420 4190 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MD704040 2 BOX J704040 AxLd 0.354 0.354 3.32E+00 9.38E+00 -4.00E-03 1.34E+00 1.000 7.38E+00
B040420 4294 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MD304040 2 BOX J304040 AxLd 0.353 0.353 3.31E+00 9.38E+00 6.87E-03 1.34E+00 1.000 7.38E+00
B040420 3673 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MD701040 2 BOX J701040 AxLd 0.343 0.343 3.22E+00 9.38E+00 -2.39E-02 1.34E+00 1.000 7.38E+00
B040420 4289 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MX701040 2 I 0.40 StaL 0.340 0.007 -1.08E-01 1.80E+01 -1.41E+00 4.89E+00 1.000 5.00E+00
I0852035 4308 0.288 4.20E+02 1.44E+01 -7.16E-02 1.62E+00 1.000 5.00E+00
0.044 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MX201040 2 I 0.40 StaL 0.328 0.009 -1.24E-01 1.80E+01 -1.35E+00 4.89E+00 1.000 5.00E+00
I0852035 3520 0.277 4.20E+02 1.44E+01 -6.93E-02 1.62E+00 1.000 5.00E+00
0.043 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MX704040 2 I 0.40 StaL 0.324 0.009 -1.24E-01 1.80E+01 -1.33E+00 4.89E+00 1.000 5.00E+00
I0852035 4345 0.273 4.20E+02 1.44E+01 6.90E-02 1.62E+00 1.000 5.00E+00
0.042 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MX204040 2 I 0.40 StaL 0.320 0.010 -1.46E-01 1.80E+01 -1.29E+00 4.89E+00 1.000 5.00E+00
I0852035 3557 0.265 4.20E+02 1.44E+01 7.25E-02 1.62E+00 1.000 5.00E+00
0.045 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MC251030 2 BOX J301040 AxLd 0.319 0.319 2.99E+00 9.38E+00 -3.27E-02 1.34E+00 1.000 7.38E+00
B040420 3564 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MZ304030 2 BOX J304040 AxLd 0.209 0.209 6.83E+00 3.27E+01 -2.10E+00 6.88E+00 1.000 6.60E+00
B060640 3663 0.000 4.20E+02 3.27E+01 1.00E-10 6.88E+00 1.000 6.60E+00
0.000 1.150 0.00E+00 6.60E+00 0.000 C , C 1 , 1

MZ704030 2 BOX J704040 AxLd 0.198 0.198 6.49E+00 3.27E+01 -2.08E+00 6.88E+00 1.000 6.60E+00
B060640 4284 0.000 4.20E+02 3.27E+01 1.00E-10 6.88E+00 1.000 6.60E+00
0.000 1.150 0.00E+00 6.60E+00 0.000 C , C 1 , 1

MZ701030 2 BOX J701040 AxLd 0.186 0.186 6.10E+00 3.27E+01 2.08E+00 6.88E+00 1.000 6.60E+00
B060640 4194 0.000 4.20E+02 3.27E+01 1.00E-10 6.88E+00 1.000 6.60E+00
0.000 1.150 0.00E+00 6.60E+00 0.000 C , C 1 , 1

MZ301030 2 BOX J301040 AxLd 0.184 0.184 6.03E+00 3.27E+01 2.09E+00 6.88E+00 1.000 6.60E+00
B060640 3573 0.000 4.20E+02 3.27E+01 1.00E-10 6.88E+00 1.000 6.60E+00
0.000 1.150 0.00E+00 6.60E+00 0.000 C , C 1 , 1

88
FRAMEWORK MEMBER CHECK, TRANSPORT
1
****** ****** ****** ****** ** *** ****
******** ******** ******** ******** *************
** ** ** ** ** ** ** ** ** ** **
** ** ** ** ** ** ** **
******* ********** ******* ********* ** ** **
******* ********* ******* ********** ** ** **
** ** ** ** ** ** ** **
** ** ** ** ** ** ** ** ** ** **
******** ******** ******** ********* ** ** **
****** ****** ****** ****** ** ** ** **

*********************************************************************************************
*********************************************************************************************
** **
** **
** ******* ****** ***** * * ******* * * ***** ****** * * **
** * * * * * ** ** * * * * * * * * * **
** * * * * * * * * * * * * * * * * * * **
** ***** ****** ******* * * * ***** * * * * * ****** *** **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * * * * * * * * * * * **
** * * * * * * * ******* ** ** ***** * * * * **
** **
** **
** Postprocessing of Frame Structures **
** **
** **
*********************************************************************************************
*********************************************************************************************

Marketing and Support by DNV Software

Program id : 3.6-02 Computer : 586


Release date : 7-JUN-2011 Impl. update :
Access time : 12-JUN-2012 09:23:46 Operating system : Win NT 6.1 [7601]
User id : 123333 CPU id : 0476028815
Installation : , EURW120334

Copyright DET NORSKE VERITAS AS, P.O.Box 300, N-1322 Hovik, Norway

DATE: 12-JUN-2012 TIME: 09:23:46 PROGRAM: SESAM FRAMEWORK 3.6-02 7-JUN-2011 1

MEMBER check: EC3/NS3472 ENV 1993-1-1/Ed 3


Run: Superelement: Loadset:
ULS T197 INPLACE
Priority....: Worst Loadcase
Usage factor: Above 0.50 SUB PAGE:

NOMENCLATURE:

Member Name of member


LoadCase Name of loadcase
CND Operational, storm or earthquake condition
Type Section type
Joint/Po Joint name or position within the member
Outcome Outcome message from the code check
UsfTot Total usage factor: UsfTot = UsfAx + UsfMy + UsfMz
UsfAx Usage factor due to axial stress
N Acting axial force
Ndy(Nkdy) Axial (buckling) force capacity about y-axis
My*ky Design bending moment used for bending about y-axis
Mdy Moment capacity for bending about y-axis
Ky Effective length factor for bending about y-axis
Ly Buckling length for bending about y-axis
Phase Phase angle in degrees
SctNam Section name
EleNum Element number
UsfMy Usage factor due to bending about y-axis
Fy Yield strength
Ndz(Nkdy) Axial (buckling) force capacity about z-axis
Mz*kz Design bending moment used for bending about z-axis
Mdz Moment capacity for bending about z-axis
Kz Effective length factor for bending about z-axis
Lz Buckling length for bending about z-axis
UsfMz Usage factor due to bending about z-axis
Gamma-m Material factor, gamma-M1
vMises Equivalent stress used in von Mises stress check
Lbuck Length between lateral support of compression flange
C1 Lateral buckling factor
BCrv y,z Buckling curve for bending about y,z-axes
Class w,f Cross section class for web, flange

DATE: 12-JUN-2012 TIME: 09:23:46 PROGRAM: SESAM FRAMEWORK 3.6-02 7-JUN-2011

MEMBER check: EC3/NS3472 ENV 1993-1-1/Ed 3


Run: Superelement: Loadset:
ULS T197 INPLACE
Priority....: Worst Loadcase

89
Member LoadCase CND Type Joint/Po Outcome UsfTot UsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MX601020 601 I 0.50 *Fa StaL 1.029 0.105 -5.91E-01 1.01E+01 -1.84E+00 2.07E+00 1.000 5.00E+00
HE800B 351 0.888 3.55E+02 5.62E+00 -1.71E-02 4.76E-01 1.000 5.00E+00
0.036 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MX301020 609 I 0.50 *Fa StaL 1.029 0.102 -5.75E-01 1.01E+01 -1.85E+00 2.07E+00 1.000 5.00E+00
HE800B 247 0.897 3.55E+02 5.62E+00 -1.40E-02 4.76E-01 1.000 5.00E+00
0.029 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MX304020 609 I 0.50 *Fa StaL 1.013 0.078 -4.40E-01 1.01E+01 -1.84E+00 2.07E+00 1.000 5.00E+00
HE800B 256 0.893 3.55E+02 5.62E+00 2.03E-02 4.76E-01 1.000 5.00E+00
0.043 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MX604020 601 I 0.50 StaL 0.997 0.088 -4.96E-01 1.01E+01 -1.80E+00 2.07E+00 1.000 5.00E+00
HE800B 360 0.869 3.55E+02 5.62E+00 1.92E-02 4.76E-01 1.000 5.00E+00
0.040 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MD454020 617 BOX 0.50 Stab 0.990 0.617 -4.44E+00 7.20E+00 4.03E-01 1.34E+00 1.000 7.49E+00
B040420 291 0.301 3.55E+02 7.20E+00 9.60E-02 1.34E+00 1.000 7.49E+00
0.072 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MC504010 625 BOX 0.50 Stab 0.971 0.608 -4.37E+00 7.20E+00 3.97E-01 1.34E+00 1.000 7.49E+00
B040420 316 0.297 3.55E+02 7.20E+00 8.94E-02 1.34E+00 1.000 7.49E+00
0.067 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MD304020 617 BOX 0.50 Stab 0.971 0.877 -1.05E+00 1.20E+00 2.38E-02 2.51E-01 1.000 8.36E+00
B020216 255 0.095 3.55E+02 1.20E+00 1.17E-18 2.51E-01 1.000 8.36E+00
0.000 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MD451020 617 BOX 0.50 Stab 0.952 0.580 -4.17E+00 7.20E+00 4.12E-01 1.34E+00 1.000 7.49E+00
B040420 289 0.308 3.55E+02 7.20E+00 -8.60E-02 1.34E+00 1.000 7.49E+00
0.064 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MC604010 625 BOX 0.50 Stab 0.944 0.851 -1.02E+00 1.20E+00 2.36E-02 2.51E-01 1.000 8.36E+00
B020216 359 0.094 3.55E+02 1.20E+00 4.08E-19 2.51E-01 1.000 8.36E+00
0.000 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MC501010 625 BOX 0.50 Stab 0.941 0.579 -4.17E+00 7.20E+00 4.05E-01 1.34E+00 1.000 7.49E+00
B040420 314 0.303 3.55E+02 7.20E+00 -7.89E-02 1.34E+00 1.000 7.49E+00
0.059 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MD301020 617 BOX 0.50 Stab 0.915 0.826 -9.93E-01 1.20E+00 2.23E-02 2.51E-01 1.000 8.36E+00
B020216 246 0.089 3.55E+02 1.20E+00 -1.19E-18 2.51E-01 1.000 8.36E+00
0.000 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MC601010 625 BOX 0.50 Stab 0.900 0.811 -9.76E-01 1.20E+00 2.25E-02 2.51E-01 1.000 8.36E+00
B020216 350 0.089 3.55E+02 1.20E+00 -1.32E-18 2.51E-01 1.000 8.36E+00
0.000 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MX301010 609 I 0.50 StaL 0.877 0.235 -2.80E+00 1.85E+01 -2.81E+00 5.44E+00 1.000 5.00E+00
I1242035 245 0.515 4.20E+02 1.19E+01 8.69E-02 6.83E-01 1.000 5.00E+00
0.127 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX304010 609 I 0.50 StaL 0.866 0.244 -2.91E+00 1.85E+01 -2.78E+00 5.44E+00 1.000 5.00E+00
I1242035 254 0.512 4.20E+02 1.19E+01 -7.49E-02 6.83E-01 1.000 5.00E+00
0.110 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX601010 601 I 0.50 StaL 0.862 0.235 -2.80E+00 1.85E+01 -2.88E+00 5.44E+00 1.000 5.00E+00
I1242035 349 0.529 4.20E+02 1.19E+01 6.62E-02 6.83E-01 1.000 5.00E+00
0.097 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX604010 601 I 0.50 StaL 0.852 0.247 -2.94E+00 1.85E+01 -2.87E+00 5.44E+00 1.000 5.00E+00
I1242035 358 0.527 4.20E+02 1.19E+01 -5.38E-02 6.83E-01 1.000 5.00E+00
0.079 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MF302020 605 BOX 0.50 Stab 0.851 0.759 -3.79E+00 4.99E+00 -1.24E-01 1.34E+00 1.000 1.20E+01
B040420 231 0.092 3.55E+02 4.99E+00 3.12E-18 1.34E+00 1.000 1.20E+01
0.000 1.150 0.00E+00 1.20E+01 0.000 C , C 1 , 1

MX404010 609 I 0.50 StaL 0.841 0.207 -2.46E+00 1.85E+01 -2.78E+00 5.44E+00 1.000 5.00E+00
I1242035 286 0.511 4.20E+02 1.19E+01 8.46E-02 6.83E-01 1.000 5.00E+00
0.124 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX504010 601 I 0.50 StaL 0.831 0.211 -2.52E+00 1.85E+01 -2.86E+00 5.44E+00 1.000 5.00E+00
I1242035 326 0.526 4.20E+02 1.19E+01 -6.44E-02 6.83E-01 1.000 5.00E+00
0.094 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX401010 625 I 0.50 StaL 0.825 0.183 -2.18E+00 1.85E+01 -2.75E+00 5.44E+00 1.000 5.00E+00
I1242035 278 0.506 4.20E+02 1.19E+01 -9.33E-02 6.83E-01 1.000 5.00E+00
0.137 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX304030 609 I 0.50 Lbck 0.809 0.000 9.03E-02 1.01E+01 1.86E+00 2.51E+00 1.000 3.30E+00
HE800B 243 0.738 3.55E+02 1.01E+01 3.37E-02 4.76E-01 1.000 3.30E+00
0.071 1.150 0.00E+00 3.30E+00 1.000 C , C 1 , 1

MX501010 601 I 0.50 StaL 0.807 0.173 -2.06E+00 1.85E+01 -2.88E+00 5.44E+00 1.000 5.00E+00
I1242035 318 0.529 4.20E+02 1.19E+01 -7.11E-02 6.83E-01 1.000 5.00E+00
0.104 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

90
Member LoadCase CND Type Joint/Po Outcome UsfTot UsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MX651030 601 I 0.50 StaL 0.802 0.005 -3.78E-02 1.01E+01 -1.96E+00 2.51E+00 1.000 3.30E+00
HE800B 362 0.779 3.55E+02 7.68E+00 -8.37E-03 4.76E-01 1.000 3.30E+00
0.018 1.150 0.00E+00 3.30E+00 1.000 C , C 1 , 1

MF702020 605 BOX 0.50 Stab 0.792 0.702 -3.50E+00 4.99E+00 -1.21E-01 1.34E+00 1.000 1.20E+01
B040420 380 0.091 3.55E+02 4.99E+00 4.15E-18 1.34E+00 1.000 1.20E+01
0.000 1.150 0.00E+00 1.20E+01 0.000 C , C 1 , 1

MX654030 601 I 0.50 StaL 0.791 0.009 -7.02E-02 1.01E+01 -1.90E+00 2.51E+00 1.000 3.30E+00
HE800B 364 0.756 3.55E+02 7.68E+00 1.26E-02 4.76E-01 1.000 3.30E+00
0.027 1.150 0.00E+00 3.30E+00 1.000 C , C 1 , 1

MX301030 609 I 0.50 StaL 0.788 0.006 -4.25E-02 1.01E+01 -1.93E+00 2.51E+00 1.000 3.30E+00
HE800B 241 0.767 3.55E+02 7.68E+00 -7.12E-03 4.76E-01 1.000 3.30E+00
0.015 1.150 0.00E+00 3.30E+00 1.000 C , C 1 , 1

MX702010 601 I 0.50 StaL 0.780 0.345 -1.94E+00 1.01E+01 -8.11E-01 1.90E+00 1.000 5.00E+00
HE800B 398 0.428 3.55E+02 5.62E+00 2.42E-03 3.06E-01 1.000 5.00E+00
0.008 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MX202010 609 I 0.50 StaL 0.767 0.351 -1.97E+00 1.01E+01 -7.77E-01 1.90E+00 1.000 5.00E+00
HE800B 204 0.409 3.55E+02 5.62E+00 1.93E-03 3.06E-01 1.000 5.00E+00
0.006 1.150 0.00E+00 5.00E+00 1.000 C , C 3 , 1

MY302030 607 I 0.50 Lbck 0.754 0.000 1.71E-02 1.81E+01 2.34E+00 3.38E+00 1.000 1.00E+01
I0852035 235 0.691 4.20E+02 1.81E+01 -1.02E-01 1.62E+00 0.100 1.00E+01
0.063 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY701010 603 I 0.50 StaL 0.746 0.035 -2.95E-01 2.01E+01 2.45E+00 4.75E+00 1.000 1.00E+01
I1252035 370 0.516 4.20E+02 8.50E+00 -2.08E-01 1.07E+00 1.000 1.00E+01
0.195 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MX804010 617 I 0.50 StaL 0.736 0.456 -4.84E+00 1.54E+01 8.82E-01 5.44E+00 1.000 5.00E+00
I1242035 435 0.162 4.20E+02 1.06E+01 8.04E-02 6.83E-01 1.000 5.00E+00
0.118 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MX602010 601 I 0.50 StaL 0.734 0.337 -1.89E+00 1.01E+01 -8.11E-01 2.07E+00 1.000 5.00E+00
HE800B 353 0.392 3.55E+02 5.62E+00 -2.06E-03 4.76E-01 1.000 5.00E+00
0.004 1.150 0.00E+00 5.00E+00 1.000 C , C 2 , 1

MX302010 609 I 0.50 StaL 0.727 0.341 -1.92E+00 1.01E+01 -7.88E-01 2.07E+00 1.000 5.00E+00
HE800B 249 0.381 3.55E+02 5.62E+00 -2.00E-03 4.76E-01 1.000 5.00E+00
0.004 1.150 0.00E+00 5.00E+00 1.000 C , C 2 , 1

MY301030 613 I 0.33 StaL 0.724 0.012 -1.87E-01 1.61E+01 -2.41E+00 3.38E+00 1.000 1.00E+01
I0852035 226 0.712 4.20E+02 1.81E+01 1.58E-03 1.62E+00 0.100 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY702030 605 I 0.50 StaL 0.721 0.006 -9.76E-02 1.61E+01 -2.29E+00 3.20E+00 1.000 1.00E+01
I0852035 384 0.715 4.20E+02 1.81E+01 3.86E-04 1.07E+00 0.100 1.00E+01
0.000 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MX801010 617 I 0.50 StaL 0.708 0.453 -4.81E+00 1.54E+01 8.49E-01 5.44E+00 1.000 5.00E+00
I1242035 427 0.156 4.20E+02 1.06E+01 6.75E-02 6.83E-01 1.000 5.00E+00
0.099 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

ME301010 613 BOX 0.50 Stab 0.706 0.626 -3.12E+00 4.99E+00 -1.08E-01 1.34E+00 1.000 1.20E+01
B040420 222 0.081 3.55E+02 4.99E+00 -2.90E-17 1.34E+00 1.000 1.20E+01
0.000 1.150 0.00E+00 1.20E+01 0.000 C , C 1 , 1

MX701010 601 I 0.50 StaL 0.701 0.318 -3.38E+00 1.54E+01 -1.39E+00 5.44E+00 1.000 5.00E+00
I1242035 394 0.255 4.20E+02 1.06E+01 -8.68E-02 6.83E-01 1.000 5.00E+00
0.127 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MD354030 617 BOX 0.50 Stab 0.698 0.524 -3.77E+00 7.20E+00 -1.85E-01 1.34E+00 1.000 7.49E+00
B040420 261 0.138 3.55E+02 7.20E+00 -4.72E-02 1.34E+00 1.000 7.49E+00
0.035 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MY301010 607 I 0.50 StaL 0.694 0.026 -2.19E-01 2.01E+01 2.35E+00 4.75E+00 1.000 1.00E+01
I1252035 221 0.495 4.20E+02 8.50E+00 1.85E-01 1.07E+00 1.000 1.00E+01
0.174 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MY701030 613 I 0.33 StaL 0.692 0.007 -1.20E-01 1.61E+01 -2.31E+00 3.38E+00 1.000 1.00E+01
I0852035 375 0.684 4.20E+02 1.81E+01 1.37E-03 1.62E+00 0.100 1.00E+01
0.001 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MC554020 625 BOX 0.50 Stab 0.683 0.515 -3.70E+00 7.20E+00 -1.80E-01 1.34E+00 1.000 7.49E+00
B040420 346 0.135 3.55E+02 7.20E+00 -4.46E-02 1.34E+00 1.000 7.49E+00
0.033 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MX101010 625 I 0.50 StaL 0.678 0.444 -4.72E+00 1.54E+01 8.48E-01 5.44E+00 1.000 5.00E+00
I1242035 169 0.156 4.20E+02 1.06E+01 5.34E-02 6.83E-01 1.000 5.00E+00
0.078 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MX104010 625 I 0.50 StaL 0.668 0.445 -4.73E+00 1.54E+01 8.69E-01 5.44E+00 1.000 5.00E+00
I1242035 177 0.160 4.20E+02 1.06E+01 -4.33E-02 6.83E-01 1.000 5.00E+00
0.063 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

91
Member LoadCase CND Type Joint/Po Outcome UsfTotUsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MX201010 609 I 0.50 StaL 0.667 0.316 -3.35E+00 1.54E+01 -1.35E+00 5.44E+00 1.000 5.00E+00
I1242035 200 0.249 4.20E+02 1.06E+01 -6.97E-02 6.83E-01 1.000 5.00E+00
0.102 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MX704010 601 I 0.50 StaL 0.664 0.318 -3.38E+00 1.54E+01 -1.30E+00 5.44E+00 1.000 5.00E+00
I1242035 403 0.239 4.20E+02 1.06E+01 7.31E-02 6.83E-01 1.000 5.00E+00
0.107 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MZ701010 601 BOX 0.50 Stab 0.656 0.362 -1.05E+01 2.91E+01 -1.33E+00 6.88E+00 1.000 6.70E+00
B060640 367 0.193 4.20E+02 2.91E+01 -6.97E-01 6.88E+00 1.000 6.70E+00
0.101 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MZ704010 601 BOX 0.50 Stab 0.656 0.346 -1.01E+01 2.91E+01 1.40E+00 6.88E+00 1.000 6.70E+00
B060640 387 0.203 4.20E+02 2.91E+01 -7.29E-01 6.88E+00 1.000 6.70E+00
0.106 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY702010 601 I 0.50 Lbck 0.648 0.000 1.08E-01 2.10E+01 2.41E+00 5.01E+00 1.000 1.00E+01
I1252035 379 0.481 4.20E+02 2.10E+01 -2.75E-01 1.64E+00 1.000 1.00E+01
0.168 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

ME701010 613 BOX 0.50 Stab 0.646 0.566 -2.82E+00 4.99E+00 -1.07E-01 1.34E+00 1.000 1.20E+01
B040420 371 0.080 3.55E+02 4.99E+00 3.14E-17 1.34E+00 1.000 1.20E+01
0.000 1.150 0.00E+00 1.20E+01 0.000 C , C 1 , 1

MX204010 609 I 0.50 StaL 0.643 0.314 -3.33E+00 1.54E+01 -1.30E+00 5.44E+00 1.000 5.00E+00
I1242035 209 0.239 4.20E+02 1.06E+01 6.15E-02 6.83E-01 1.000 5.00E+00
0.090 1.150 0.00E+00 5.00E+00 1.000 C , C 4 , 1

MZ304010 609 BOX 0.50 Stab 0.639 0.350 -1.02E+01 2.91E+01 1.26E+00 6.88E+00 1.000 6.70E+00
B060640 238 0.184 4.20E+02 2.91E+01 7.30E-01 6.88E+00 1.000 6.70E+00
0.106 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MD351030 617 BOX 0.50 Stab 0.634 0.483 -3.47E+00 7.20E+00 -1.71E-01 1.34E+00 1.000 7.49E+00
B040420 260 0.128 3.55E+02 7.20E+00 3.15E-02 1.34E+00 1.000 7.49E+00
0.024 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MZ504010 601 BOX 0.50 Stab 0.629 0.093 -1.49E+00 1.60E+01 -5.90E-01 2.85E+00 1.000 6.70E+00
B040440 311 0.207 4.20E+02 1.60E+01 9.40E-01 2.85E+00 1.000 6.70E+00
0.330 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MC551020 601 BOX J651030 AxLd 0.629 0.629 5.91E+00 9.38E+00 4.02E-01 1.34E+00 1.000 7.49E+00
B040420 345 0.000 3.55E+02 9.38E+00 2.52E-02 1.34E+00 1.000 7.49E+00
0.000 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MZ301010 609 BOX 0.50 Stab 0.627 0.354 -1.03E+01 2.91E+01 -1.19E+00 6.88E+00 1.000 6.70E+00
B060640 218 0.173 4.20E+02 2.91E+01 6.92E-01 6.88E+00 1.000 6.70E+00
0.101 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MZ501010 601 BOX 0.50 Stab 0.625 0.132 -2.11E+00 1.60E+01 4.74E-01 2.85E+00 1.000 6.70E+00
B040440 293 0.166 4.20E+02 1.60E+01 9.29E-01 2.85E+00 1.000 6.70E+00
0.326 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MZ701020 615 BOX 0.50 Stab 0.622 0.286 -8.32E+00 2.91E+01 1.36E+00 6.88E+00 1.000 6.70E+00
B060640 368 0.198 4.20E+02 2.91E+01 -9.51E-01 6.88E+00 1.000 6.70E+00
0.138 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MZ301020 611 BOX 0.50 Stab 0.621 0.282 -8.21E+00 2.91E+01 1.43E+00 6.88E+00 1.000 6.70E+00
B060640 219 0.208 4.20E+02 2.91E+01 8.95E-01 6.88E+00 1.000 6.70E+00
0.130 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MY302010 609 I 0.50 Lbck 0.618 0.000 1.75E-01 2.10E+01 2.34E+00 5.01E+00 1.000 1.00E+01
I1252035 230 0.467 4.20E+02 2.10E+01 2.48E-01 1.64E+00 1.000 1.00E+01
0.151 1.150 0.00E+00 1.00E+01 1.000 C , C 2 , 2

MZ304020 607 BOX 0.50 Stab 0.611 0.280 -8.14E+00 2.91E+01 -1.44E+00 6.88E+00 1.000 6.70E+00
B060640 239 0.209 4.20E+02 2.91E+01 8.37E-01 6.88E+00 1.000 6.70E+00
0.122 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MZ704020 603 BOX 0.50 Stab 0.602 0.274 -7.98E+00 2.91E+01 -1.32E+00 6.88E+00 1.000 6.70E+00
B060640 388 0.192 4.20E+02 2.91E+01 -9.30E-01 6.88E+00 1.000 6.70E+00
0.135 1.150 0.00E+00 6.70E+00 0.000 C , C 1 , 1

MC204010 627 BOX 0.50 Stab 0.577 0.513 -6.17E-01 1.20E+00 -5.15E-03 2.51E-01 1.000 8.36E+00
B020216 210 0.020 3.55E+02 1.20E+00 1.08E-02 2.51E-01 1.000 8.36E+00
0.043 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MY901040 605 I 0.50 StaL 0.572 0.463 -9.55E-01 8.52E+00 -1.07E-01 1.12E+00 1.000 1.00E+01
HE800B 451 0.095 3.55E+02 2.06E+00 4.46E-03 3.06E-01 1.000 1.00E+01
0.015 1.150 0.00E+00 1.00E+01 1.000 C , C 4 , 1

MC201010 623 BOX 0.50 Stab 0.567 0.504 -6.07E-01 1.20E+00 -4.96E-03 2.51E-01 1.000 8.36E+00
B020216 201 0.020 3.55E+02 1.20E+00 -1.08E-02 2.51E-01 1.000 8.36E+00
0.043 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MF902520 607 BOX 0.50 Stab 0.566 0.223 -1.61E+00 7.20E+00 2.48E-01 1.34E+00 1.000 7.49E+00
B040420 463 0.186 3.55E+02 7.20E+00 2.11E-01 1.34E+00 1.000 7.49E+00
0.158 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

92
Member LoadCase CND Type Joint/Po Outcome UsfTot UsfAx N Ndy(Nkdy) My*ky Mdy Ky Ly
Phase SctNam EleNum UsfMy Fy Ndz(Nkdy) Mz*kz Mdz Kz Lz
UsfMz Gamma-m vMises Lbuck C1 BCrv y,z Class w,f
----------------------------------------------------------------------------------------------------------------------------
MY501020 609 I 0.50 StaL 0.553 0.015 -3.00E-01 2.01E+01 1.96E+00 4.75E+00 1.000 1.00E+01
I1252035 299 0.412 4.20E+02 2.10E+01 1.35E-01 1.07E+00 0.100 1.00E+01
0.127 1.150 0.00E+00 1.00E+01 1.000 C , C 3 , 2

MD704020 631 BOX 0.50 Stab 0.553 0.489 -5.88E-01 1.20E+00 -5.26E-03 2.51E-01 1.000 8.36E+00
B020216 404 0.021 3.55E+02 1.20E+00 1.08E-02 2.51E-01 1.000 8.36E+00
0.043 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MX204020 603 I 0.50 StaL 0.543 0.062 -3.50E-01 1.01E+01 -9.12E-01 2.07E+00 1.000 5.00E+00
HE800B 211 0.441 3.55E+02 5.62E+00 1.87E-02 4.76E-01 1.000 5.00E+00
0.039 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

ME901010 613 BOX 0.50 Stab 0.536 0.259 -1.86E+00 7.20E+00 2.63E-01 1.34E+00 1.000 7.49E+00
B040420 445 0.197 3.55E+02 7.20E+00 1.08E-01 1.34E+00 1.000 7.49E+00
0.081 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MC651030 601 BOX J701040 AxLd 0.535 0.535 5.03E+00 9.38E+00 -9.85E-02 1.34E+00 1.000 7.38E+00
B040420 363 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MD301040 609 BOX J301040 AxLd 0.532 0.532 4.99E+00 9.38E+00 -9.52E-02 1.34E+00 1.000 7.38E+00
B040420 242 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MD701020 619 BOX 0.50 Stab 0.530 0.467 -5.62E-01 1.20E+00 -5.06E-03 2.51E-01 1.000 8.36E+00
B020216 395 0.020 3.55E+02 1.20E+00 -1.08E-02 2.51E-01 1.000 8.36E+00
0.043 1.150 0.00E+00 8.36E+00 0.000 C , C 1 , 1

MX302020 609 I 0.50 Lbck 0.528 0.000 2.29E-02 1.81E+01 2.57E+00 4.89E+00 1.000 5.00E+00
I0852035 250 0.526 4.20E+02 1.81E+01 -3.46E-03 1.62E+00 1.000 5.00E+00
0.002 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MX202020 609 I 0.50 Lbck 0.527 0.000 3.76E-02 1.81E+01 2.55E+00 4.89E+00 1.000 5.00E+00
I0852035 205 0.521 4.20E+02 1.81E+01 9.06E-03 1.62E+00 1.000 5.00E+00
0.006 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 2

MX701020 611 I 0.50 StaL 0.522 0.061 -3.46E-01 1.01E+01 -8.76E-01 2.07E+00 1.000 5.00E+00
HE800B 396 0.424 3.55E+02 5.62E+00 -1.74E-02 4.76E-01 1.000 5.00E+00
0.037 1.150 0.00E+00 5.00E+00 1.000 C , C 1 , 1

MY101010 615 I 0.50 StaL 0.513 0.033 -2.99E-01 9.04E+00 4.56E-01 1.17E+00 1.000 1.00E+01
HE800B 146 0.390 3.55E+02 1.01E+01 -4.30E-02 4.76E-01 0.100 1.00E+01
0.090 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 1

MF102520 605 BOX 0.50 Stab 0.508 0.310 -2.23E+00 7.20E+00 -2.44E-01 1.34E+00 1.000 7.49E+00
B040420 156 0.182 3.55E+02 7.20E+00 -2.03E-02 1.34E+00 1.000 7.49E+00
0.015 1.150 0.00E+00 7.49E+00 0.000 C , C 1 , 1

MC654030 601 BOX J704040 AxLd 0.502 0.502 4.71E+00 9.38E+00 -1.14E-01 1.34E+00 1.000 7.38E+00
B040420 365 0.000 3.55E+02 9.38E+00 1.00E-10 1.34E+00 1.000 7.38E+00
0.000 1.150 0.00E+00 7.38E+00 0.000 C , C 1 , 1

MY902010 609 I 0.50 Lbck 0.501 0.000 2.85E-01 1.81E+01 1.03E+00 3.38E+00 1.000 1.00E+01
I0852035 460 0.303 4.20E+02 1.81E+01 3.21E-01 1.62E+00 0.100 1.00E+01
0.197 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

MY901010 609 I 0.50 Lbck 0.501 0.000 2.76E-01 1.81E+01 1.03E+00 3.38E+00 1.000 1.00E+01
I0852035 449 0.304 4.20E+02 1.81E+01 3.19E-01 1.62E+00 0.100 1.00E+01
0.197 1.150 0.00E+00 1.00E+01 1.000 C , C 1 , 2

93
MEMBER ASSESSMENT

In place

94
Lift

95
Transport

96
97
98
F. DESIGN CHECK OF PADEYES

99
100
101
102
103
G. DESIGN CHECK OF JOINTS
QuickNodeCheck - Screening - Inplace - Master module
- Joint UF based on a combination of incoming members UF's
- Check "Readme" sheet for explanations

(*) - The three highest UF's are used with the worst possible
sign combination of normal stresses in a 3D Von Mises check.

Joint Translational Longitudinal Vertical UF (*) Joint Translational Longitudinal Vertical UF (*)
(A,B,X) (Y) (C,D,E,F,Z) (A,B,X) (Y) (C,D,E,F,Z)
J101010 0.236 0.389 0.511 0.83 J501040 0.070 0.173 0.333 0.46
J101020 0.119 0.104 0.184 0.30 J502010 0.065 0.258 0.000 0.30
J101030 0.128 0.147 0.158 0.30 J502020 0.059 0.312 0.000 0.35
J101040 0.055 0.115 0.135 0.23 J502030 0.110 0.260 0.000 0.33
J101320 0.000 0.300 0.402 0.61 J502040 0.121 0.251 0.000 0.33
J101520 0.000 0.168 0.000 0.17 J504010 0.242 0.203 0.588 0.81
J101530 0.000 0.143 0.000 0.14 J504020 0.201 0.246 0.504 0.73
J101540 0.000 0.044 0.000 0.04 J504030 0.075 0.252 0.314 0.50
J101730 0.000 0.228 0.299 0.46 J504040 0.065 0.166 0.337 0.46
J102010 0.054 0.414 0.000 0.44 J551020 0.267 0.000 0.449 0.63
J102020 0.053 0.226 0.000 0.26 J554020 0.267 0.000 0.464 0.64
J102030 0.075 0.125 0.000 0.18 J601010 0.136 0.069 0.000 0.18
J102040 0.399 0.399 0.472 0.87 J601020 0.215 0.107 0.000 0.28
J102520 0.000 0.323 0.454 0.68 J601030 0.155 0.085 0.000 0.21
J102530 0.000 0.277 0.337 0.53 J601040 0.103 0.066 0.000 0.15
J104010 0.257 0.407 0.565 0.91 J602010 0.121 0.145 0.000 0.23
J104020 0.143 0.076 0.203 0.32 J602020 0.120 0.115 0.000 0.20
J104030 0.126 0.136 0.189 0.32 J602030 0.151 0.142 0.000 0.25
J104040 0.110 0.354 0.216 0.53 J602040 0.061 0.153 0.000 0.19
J151020 0.163 0.000 0.408 0.51 J604010 0.133 0.065 0.000 0.17
J154020 0.241 0.000 0.469 0.63 J604020 0.212 0.104 0.000 0.28
J201010 0.171 0.088 0.000 0.23 J604030 0.161 0.082 0.000 0.21
J201020 0.186 0.080 0.000 0.24 J604040 0.095 0.067 0.000 0.14
J201030 0.142 0.071 0.000 0.19 J651030 0.171 0.000 0.398 0.51
J201040 0.075 0.075 0.000 0.13 J654030 0.172 0.000 0.426 0.53
J201520 0.000 0.151 0.000 0.15 J701005 0.000 0.000 0.076 0.08
J201530 0.000 0.115 0.000 0.12 J701010 0.420 0.425 0.570 0.99
J201540 0.000 0.141 0.000 0.14 J701020 0.394 0.420 0.581 0.99
J202010 0.170 0.162 0.000 0.29 J701030 0.332 0.412 0.379 0.77
J202020 0.132 0.064 0.000 0.17 J701040 0.172 0.258 0.316 0.54
J202030 0.222 0.074 0.000 0.27 J702010 0.424 0.345 0.000 0.67
J202040 0.386 0.173 0.000 0.50 J702020 0.166 0.347 0.000 0.45
J204010 0.185 0.074 0.000 0.23 J702030 0.128 0.309 0.000 0.39
J204020 0.176 0.077 0.000 0.22 J702040 0.213 0.242 0.000 0.39
J204030 0.185 0.113 0.000 0.26 J704005 0.000 0.000 0.075 0.08
J204040 0.149 0.137 0.000 0.25 J704010 0.423 0.477 0.575 1.03
J251030 0.142 0.000 0.383 0.47 J704020 0.397 0.444 0.584 1.01
J254030 0.196 0.000 0.462 0.59 J704030 0.339 0.404 0.384 0.77
J301005 0.000 0.000 0.082 0.08 J704040 0.168 0.247 0.311 0.52
J301010 0.446 0.427 0.577 1.01 Ref J304010 J751030 0.172 0.000 0.351 0.46
J301020 0.387 0.421 0.602 1.01 Ref J304020 J754030 0.163 0.000 0.371 0.47
J301030 0.363 0.407 0.380 0.78 J801010 0.148 0.097 0.000 0.21
J301040 0.186 0.366 0.426 0.72 J801020 0.145 0.064 0.000 0.19
J302010 0.380 0.312 0.000 0.60 J801030 0.123 0.070 0.000 0.17
J302020 0.219 0.391 0.000 0.54 J801040 0.074 0.064 0.000 0.12
J302030 0.168 0.304 0.000 0.41 J802010 0.277 0.214 0.000 0.43
J302040 0.217 0.383 0.000 0.53 J802020 0.169 0.075 0.000 0.22
J304005 0.000 0.000 0.087 0.09 J802030 0.227 0.102 0.000 0.29
J304010 0.452 0.476 0.601 1.07 Checked J802040 0.285 0.115 0.000 0.36
J304020 0.388 0.456 0.624 1.05 checked J804010 0.145 0.095 0.000 0.21
J304030 0.392 0.458 0.409 0.86 J804020 0.195 0.056 0.000 0.23
J304040 0.272 0.430 0.489 0.85 J804030 0.113 0.063 0.000 0.15
J351030 0.195 0.000 0.400 0.53 J804040 0.064 0.060 0.000 0.11
J354030 0.195 0.000 0.397 0.52 J851020 0.220 0.000 0.387 0.53
J401010 0.161 0.071 0.000 0.21 J854020 0.187 0.000 0.409 0.53
J401020 0.215 0.120 0.000 0.29 J901010 0.225 0.297 0.537 0.80
J401030 0.150 0.084 0.000 0.21 J901020 0.122 0.091 0.203 0.31
J401040 0.110 0.077 0.000 0.16 J901030 0.118 0.122 0.156 0.28
J402010 0.160 0.147 0.000 0.27 J901040 0.050 0.099 0.143 0.22
J402020 0.175 0.105 0.000 0.25 J901520 0.000 0.208 0.366 0.50
J402030 0.161 0.131 0.000 0.25 J901530 0.000 0.216 0.207 0.37
J402040 0.252 0.241 0.000 0.43 J902010 0.074 0.330 0.000 0.37
J404010 0.158 0.068 0.000 0.20 J902020 0.094 0.298 0.000 0.35
J404020 0.215 0.111 0.000 0.29 J902030 0.098 0.264 0.000 0.32
J404030 0.155 0.082 0.000 0.21 J902040 0.266 0.159 0.316 0.54
J404040 0.175 0.146 0.000 0.28 J902520 0.000 0.270 0.438 0.62
J451020 0.257 0.000 0.464 0.63 J902530 0.000 0.326 0.265 0.51
J454020 0.276 0.000 0.461 0.64 J904010 0.215 0.292 0.557 0.81
J501010 0.236 0.203 0.588 0.81 J904020 0.228 0.287 0.210 0.51
J501020 0.201 0.229 0.500 0.72 J904030 0.137 0.146 0.145 0.29
J501030 0.075 0.257 0.314 0.51 J904040 0.063 0.159 0.128 0.26
Figure G-1 Screening Inplace condition

104
QuickNodeCheck - Screening - Lift - Master Module
- Joint UF based on a combination of incoming members UF's
- Check "Readme" sheet for explanations

(*) - The three highest UF's are used with the worst possible
sign combination of normal stresses in a 3D Von Mises check.

Joint Translational Longitudinal Vertical UF (*) Joint Translational Longitudinal Vertical UF (*)
(A,B,X) (Y) (C,D,E,F,Z) (A,B,X) (Y) (C,D,E,F,Z)
J101010 0.118 0.382 0.373 0.67 J501040 0.228 0.283 0.526 0.78
J101020 0.088 0.088 0.155 0.24 J502010 0.603 0.177 0.468 0.96
J101030 0.073 0.048 0.109 0.17 J502020 0.291 0.507 0.000 0.70
J101040 0.040 0.063 0.111 0.16 J502030 0.207 0.552 0.000 0.68
J101320 0.000 0.164 0.238 0.35 J502040 0.262 0.447 0.000 0.62
J101520 0.000 0.073 0.000 0.07 J504010 0.214 0.190 0.518 0.72
J101530 0.000 0.015 0.000 0.02 J504020 0.320 0.379 0.659 1.01 checked
J101540 0.000 0.053 0.000 0.05 J504030 0.077 0.497 0.595 0.95
J101730 0.000 0.137 0.153 0.25 J504040 0.170 0.291 0.545 0.78
J102010 0.097 0.433 0.000 0.49 J551020 0.287 0.000 0.522 0.71
J102020 0.050 0.180 0.000 0.21 J554020 0.274 0.000 0.410 0.60
J102030 0.090 0.124 0.000 0.19 J601010 0.114 0.113 0.369 0.48
J102040 0.276 0.051 0.269 0.48 J601020 0.224 0.167 0.000 0.34
J102520 0.000 0.189 0.271 0.40 J601030 0.289 0.151 0.000 0.39
J102530 0.000 0.167 0.161 0.28 J601040 0.288 0.113 0.000 0.36
J104010 0.122 0.415 0.382 0.70 J602010 0.255 0.144 0.000 0.35
J104020 0.083 0.075 0.153 0.23 J602020 0.330 0.145 0.000 0.42
J104030 0.057 0.020 0.055 0.10 J602030 0.285 0.304 0.000 0.51
J104040 0.039 0.034 0.078 0.11 J602040 0.352 0.376 0.000 0.63
J151020 0.181 0.000 0.309 0.43 J604010 0.146 0.104 0.325 0.45
J154020 0.197 0.000 0.370 0.50 J604020 0.199 0.156 0.000 0.31
J201010 0.081 0.123 0.229 0.33 J604030 0.263 0.142 0.000 0.36
J201020 0.174 0.101 0.000 0.24 J604040 0.257 0.114 0.000 0.33
J201030 0.194 0.108 0.000 0.27 J651030 0.312 0.000 0.547 0.75
J201040 0.095 0.089 0.000 0.16 J654030 0.277 0.000 0.430 0.62
J201520 0.000 0.163 0.000 0.16 J701005 0.000 0.000 0.000 0.00
J201530 0.000 0.193 0.000 0.19 J701010 0.158 0.409 0.502 0.82
J201540 0.000 0.186 0.000 0.19 J701020 0.266 0.291 0.349 0.63
J202010 0.359 0.251 0.000 0.53 J701030 0.227 0.684 0.495 1.07 Ref J304030
J202020 0.231 0.150 0.000 0.33 J701040 0.594 0.623 0.527 1.18 Ref J304040
J202030 0.309 0.164 0.000 0.42 J702010 0.469 0.567 0.000 0.90
J202040 0.262 0.152 0.000 0.36 J702020 0.571 0.092 0.453 0.90
J204010 0.076 0.114 0.211 0.31 J702030 0.172 0.514 0.000 0.62
J204020 0.122 0.089 0.000 0.18 J702040 0.313 0.450 0.000 0.66
J204030 0.336 0.224 0.000 0.49 J704005 0.000 0.000 0.000 0.00
J204040 0.097 0.090 0.000 0.16 J704010 0.163 0.477 0.559 0.92
J251030 0.237 0.000 0.382 0.54 J704020 0.228 0.294 0.337 0.60
J254030 0.375 0.000 0.457 0.72 J704030 0.163 0.667 0.508 1.05 Ref J304030
J301005 0.000 0.000 0.000 0.00 J704040 0.539 0.616 0.539 1.16 Ref J304040
J301010 0.144 0.378 0.458 0.75 J751030 0.252 0.000 0.415 0.58
J301020 0.266 0.276 0.343 0.61 J754030 0.255 0.000 0.433 0.60
J301030 0.208 0.700 0.503 1.09 Ref J304030 J801010 0.078 0.160 0.249 0.37
J301040 0.580 0.620 0.526 1.17 Ref J304010 J801020 0.091 0.065 0.000 0.14
J302010 0.343 0.509 0.000 0.74 J801030 0.201 0.109 0.000 0.27
J302020 0.714 0.117 0.466 1.05 J801040 0.099 0.090 0.000 0.16
J302030 0.211 0.558 0.000 0.69 J802010 0.478 0.307 0.000 0.69
J302040 0.312 0.447 0.000 0.66 J802020 0.157 0.088 0.000 0.21
J304005 0.000 0.000 0.000 0.00 J802030 0.240 0.185 0.000 0.37
J304010 0.149 0.444 0.515 0.85 J802040 0.268 0.159 0.000 0.37
J304020 0.231 0.291 0.315 0.58 J804010 0.089 0.151 0.225 0.35
J304030 0.140 0.807 0.557 1.21 Checked J804020 0.234 0.058 0.000 0.27
J304040 0.543 0.626 0.552 1.17 Checked J804030 0.193 0.098 0.000 0.26
J351030 0.328 0.000 0.536 0.76 J804040 0.097 0.088 0.000 0.16
J354030 0.304 0.000 0.432 0.64 J851020 0.238 0.000 0.390 0.55
J401010 0.106 0.118 0.354 0.47 J854020 0.309 0.000 0.419 0.63
J401020 0.250 0.185 0.000 0.38 J901010 0.136 0.435 0.599 0.92
J401030 0.306 0.162 0.000 0.41 J901020 0.082 0.158 0.255 0.38
J401040 0.288 0.113 0.000 0.36 J901030 0.077 0.036 0.111 0.17
J402010 0.368 0.147 0.000 0.46 J901040 0.041 0.039 0.115 0.16
J402020 0.479 0.189 0.000 0.60 J901520 0.000 0.121 0.317 0.39
J402030 0.364 0.305 0.000 0.58 J901530 0.000 0.132 0.127 0.22
J402040 0.355 0.374 0.000 0.63 J902010 0.123 0.500 0.000 0.57
J404010 0.119 0.108 0.308 0.42 J902020 0.019 0.116 0.000 0.13
J404020 0.265 0.201 0.000 0.40 J902030 0.072 0.231 0.000 0.27
J404030 0.284 0.154 0.000 0.38 J902040 0.266 0.062 0.251 0.45
J404040 0.261 0.113 0.000 0.33 J902520 0.000 0.133 0.334 0.42
J451020 0.296 0.000 0.495 0.69 J902530 0.000 0.220 0.114 0.29
J454020 0.301 0.000 0.369 0.58 J904010 0.131 0.443 0.585 0.91
J501010 0.221 0.157 0.505 0.70 J904020 0.155 0.170 0.251 0.41
J501020 0.481 0.446 0.644 1.11 Not Checked J904030 0.118 0.055 0.101 0.20
J501030 0.126 0.495 0.589 0.95 J904040 0.043 0.032 0.106 0.14
Figure G-2 Screening Lift condition

105
Joint check - Inplace - Master module
Base deck

INPUT
Node
J304010 MX1 MX2 MY MZ1 MZ2
Member MX204010 MX304010 MY302010 MZ304005 MZ304010
Section I1242035 I1242035 I1252035 SUPP B060640

RESULTS Material properties


UFmax Dim LC gm 1.15
0.94 542 fy 355 MPa

Equations:
FYMY MXMY MZMY
FXMX2 MYMX2 MZMX2 sy.2T  
sx.1T    A MY W y.MY W Z.MY FXMZ2 FYMZ2 MZMZ2
A Mx W y.MX W Z.MX
t xy.1.2.3.4.  
FXMX2 MYMX2 MZMX2
FYMY MXMZ2 MZMY 2Tw.MZ BMZ 2.Tf.MZ HMZ HMZ2  Tf.MZ2BMZ.Tf.MZ
sy.4T  
sx.2T    A MY W y.MY W Z.MY
A Mx W y.MX W Z.MX FXMY MYMY FZ
t xz.2.4.  
FXMX1 MYMX1 MZMX1 sy.2B
FYMY

MXMY

MZMY 2Tf.MY BMY HMY  Tf.MyBMYTfMY HMY tw.MY
sx.3T   A MY W y.MY W Z.MY
A Mx W y.MX W Z.MX
FYMX2 MYMX2 FZ
FYMY MXMY MZMY syz.1.2.  
sx.4T
FXMX1

MYMX1

MYMX2 sy.4B    2Tw.MY BMX HMX  Tf.MXBMYTf.MX HMX twMX
A MY W y.MY W Z.MY
A Mx W y.MX W Z.MX
FYMX1 MYMX2 FZ
syz.3.4.  
sx.1B 
FXMX2

MYMX2

MZMX2
sz.1T 
FZMZ2

MXMZ2

MYMZ2 2Tw.MX BMX  
HMX  Tf.MX  BMX Tf.MX HMX tw.MX
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ

FXMX2 MYMX2 MZMX2 FZMZ2 MXMZ2 MYMZ2


sx.2B    sz.2T   
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ

FXMX1 MYMX1 MZMX1 FZMZ2 MXMZ2 MYMZ2


sx.3B   sz.3T   
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ

FXMX1 MYMX1 MZMX1


sx.4B   FZMZ2 MXMZ2 MYMZ2
A Mx W y.MX W Z.MX sz.4T   
A Mz W y.MZ W Z.MZ

Incoming beam - y-dir Continuous deck beam - x-dir Incoming beam - column Incoming beam - column
Section I1252035 Section I1242035 Section B060640 Section SUPP
HMY 1200 mm HMX 1200 mm HMZ 600 mm HMZ 850 mm
BMY 500 mm BMX 400 mm BMZ 600 mm BMZ 850 mm
Tf-MY 35 mm Tf-MX 35 mm Tf-MZ 40 mm Tf-MZ 60 mm
Tw-MY 20 mm Tw-MX 20 mm Tw-MZ 40 mm Tw-MZ 60 mm
a 5.0 mm A MX 5.06E+04 mm2 A MZ 8.96E+04 mm2 A MZ 1.46E+05 mm2
A MY 5.76E+04 mm2 Wx-MX 7.22E+05 mm3 Wx-MZ 2.51E+07 mm3 Wx-MZ 2.92E+06 mm3
Wy-MY 2.38E+07 mm3 Wy-MX 1.98E+07 mm3 Wy-MZ 1.57E+07 mm3 Wy-MZ 4.67E+07 mm3
Wz-MY 2.92E+06 mm3 Wz-MX 1.87E+06 mm3 Wz-MZ 1.57E+07 mm3 Wz-MZ 1.45E+07 mm3

Top flange Bottom flange Shear stresses Von-Mises


Member LoadC SctNam Fx Fy Fz Mx My Mz Hot spot sx-T sy-T sz-T sx-B sy-B sz-B tyz txz txy-T sj-T sj-B tfill UF
(kN) (kN) (kN) (kNm) (kNm) (kNm) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa)
MX204010 542 I1242035 -1687 -7 426 -1 2429 17 1 -13 -177 25 145 9 13 173 137 0.94
MX304010 542 I1242035 -21 2 214 -1 -372 10 2 -24 115 45 14 -152 -49 9 27 13 132 155
MY302010 542 I1252035 -19 -476 644 -3170 0 -30 3 -165 -171 80 -156 18 13 172 211
MZ304005 542 SUPP 2015 1522 -7176 1522 -2015 0 4 -147 135 45 98 -131 -221 18 27 13 257 291
MZ304010 542 B060640 -66 -534 5889 1692 -46 3

MX204010 543 I1242035 -1833 -2 402 -1 2285 5 1 -78 -189 45 111 14 14 168 102 0.88
MX304010 543 I1242035 644 -5 325 -1 -1213 -7 2 -70 149 55 52 -172 -140 14 30 14 200 219
MY302010 543 I1252035 0 -689 714 -3830 0 1 3 -154 -219 76 -56 17 14 199 121
MZ304005 543 SUPP 1312 1970 -8802 1970 -1312 0 4 -149 149 25 82 -173 -193 17 30 14 266 273
MZ304010 543 B060640 43 -615 7357 1912 238 1

MX204010 544 I1242035 -1264 4 315 -1 1655 -11 1 -141 -172 75 -12 19 14 164 92 0.90
MX304010 544 I1242035 1126 -10 443 -1 -2140 -20 2 -119 136 50 96 -133 -204 19 28 14 234 279
MY302010 544 I1252035 19 -525 653 -3203 0 32 3 -103 -229 64 -6 13 14 201 76
MZ304005 544 SUPP -46 1506 -9433 1506 46 0 4 -114 115 -6 53 -155 -198 13 28 14 207 240
MZ304010 544 B060640 139 -549 8018 1742 440 -1

Figure G-3 Local analysis Joint 304010, inplace condition

106
Joint check - Inplace - Master module
Lower deck

INPUT
Node
J304020 MX1 MX2 MY MZ1 MZ2
Member MX204020 MX304020 MY302020 MZ304010 MZ304020
Section HE800B HE800B I1242035 B060640 B060640

RESULTS Material properties


UFmax Dim LC gm 1.15
1.08 543 fy 355 MPa

Equations: FZMZ1 MXMZ1 MYMZ1


sz.1B  
A Mz W y.MZ W Z.MZ
FYMY MXMY MZMY
FXMX2 MYMX2 MZMX2 sy.2T  
sx.1T    A MY W y.MY W Z.MY FZMZ1 MXMZ1 MYMZ1
A Mx W y.MX W Z.MX sz.2B  
A Mz W y.MZ W Z.MZ
FYMY MXMZ2 MZMY
FXMX2 MYMX2 MZMX2 sy.4T  
sx.2T    A MY W y.MY W Z.MY FZMZ1 MXMZ1 MYMZ1
A Mx W y.MX W Z.MX sz.3B  
A Mz W y.MZ W Z.MZ
FYMY MXMY MZMY
FXMX1 MYMX1 MZMX1 sy.2B  
sx.3T   A MY W y.MY W Z.MY
A Mx W y.MX W Z.MX FZMZ1 MXMZ1 MYMZ1
sz.4B  
FYMY MXMY MZMY A Mz W y.MZ W Z.MZ
FXMX1 MYMX1 MZMX1 sy.4B  
sx.4T   A MY W y.MY W Z.MY
A Mx W y.MX W Z.MX FXMZ2 FYMZ2 MZMZ2
t xy.1.2.3.4.T.  
FZMZ2 MXMZ2 MYMZ2
2Tf.MZ BMZ 2.Tf.Mz HMZ HMZ2  Tf.MZ2 BMZ Tf.MZ
FXMX2 MYMX2 MZMX2 sz.1T   
sx.1B    A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX FXMZ1 FYMZ1 MZMZ1
t xy.1.2.3.4.B.  
FXMX2 MYMX2 MZMX2 sz.2T 
FZMZ2

MXMZ2

MYMZ2 2Tf.MZ BMZ 2.Tf.Mz HMZ HMZ2  Tf.MZ1 BMZ Tf.MZ
sx.2B    A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FXMY MYMY FZMY
t xz.2.4.  
HMY  Tf.MY BMY TfMY
FZMZ2 MXMZ2 MYMZ2
FXMX1 MYMX1 MZMX1 sz.3T    2Tf.MY BMY HMY tw.MY
sx.3B   A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMX2 MXMX2 FZMX2
syz.1.2.  
HMX  Tf.MX BMX Tf.MX
FXMX1 MYMX1 MZMX1 FZMZ2 MXMZ2 MYMZ2
sx.4B   sz.4T    2Tw.MY BMX HMX twMX
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ
FYMX1 MXMX2 FZMX1
syz.3.4.  
2Tw.MX BMX HMX  Tf.MX BMX Tf.MX HMX tw.MX
Incoming beam - y-dir Continuous deck beam - x-dir Incoming beam - column
Section I1242035 Section HE800B Section B060640
Note (1):
HMY 1200 mm HMX 800 mm HMZ 600 mm Weld at w eb is assumed to carry shear only
BMY 400 mm BMX 300 mm BMZ 600 mm Note (2):
Tf-MY 35 mm (2) Tf-MX 33 mm Tf-MZ 40 mm (2) Part pen w eld
Tw-MY 20 mm (1) Tw-MX 17.5 mm Tw-MZ 40 mm (2)
a 5.0 mm A MX 3.26E+04 mm2 A MZ 8.96E+04 mm2
A MY 5.06E+04 mm2 Wx-MX 4.86E+05 mm3 Wx-MZ 2.51E+07 mm3
Wy-MY 1.98E+07 mm3 Wy-MX 8.73E+06 mm3 Wy-MZ 1.57E+07 mm3
Wz-MY 1.87E+06 mm3 Wz-MX 9.92E+05 mm3 Wz-MZ 1.57E+07 mm3

Top flange Bottom flange Shear stresses Von-Mises


Member LoadC SctNam Fx Fy Fz Mx My Mz Hot spot sx-T sy-T sz-T sx-B sy-B sz-B tyz txz txy-T sj-T sj-B tfill UF
(kN) (kN) (kN) (kNm) (kNm) (kNm) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa)
MX204020 523 HE800B -28 0 207 0 708 0 1 79 -152 -83 23 16 7 206 101 0.95
MX304020 523 HE800B 66 0 217 -1 -706 0 2 79 141 5 -83 141 -183 16 32 7 134 294
MY302020 523 I1242035 0 -103 765 -2838 0 0 3 80 -145 -82 16 15 7 263 95
MZ304010 523 B060640 -29 490 -7498 1623 57 -1 4 80 141 11 -82 141 -183 15 32 7 128 294
MZ304020 523 B060640 -16 -337 6311 1230 -53 1

MX204020 542 HE800B 91 -3 242 0 820 6 1 31 -135 -24 30 6 9 154 50 1.01


MX304020 542 HE800B 5 0 78 -1 -237 4 2 23 139 -2 -31 139 -204 6 28 9 140 302
MY302020 542 I1242035 -9 -152 673 -2871 0 -5 3 91 -106 -97 75 18 9 231 153
MZ304010 542 B060640 52 520 -5808 1841 -349 -3 4 103 145 27 -85 145 -204 18 28 9 119 313
MZ304020 542 B060640 -99 -320 4816 1044 -231 -1

MX204020 543 HE800B 82 -2 208 -1 750 2 1 72 -149 -74 59 14 8 197 118 1.08
MX304020 543 HE800B -17 -2 188 -1 -637 -2 2 75 159 -9 -71 159 -215 14 30 8 157 332
MY302020 543 I1242035 0 -178 715 -3226 0 0 3 86 -129 -85 52 15 8 261 124
MZ304010 543 B060640 -43 596 -7276 2145 48 -1 4 90 159 11 -81 159 -215 15 30 8 141 333
MZ304020 543 B060640 -50 -350 6167 1097 -157 0

MX204020 544 HE800B 4 0 147 0 561 -3 1 108 -146 -120 60 21 8 224 163 1.00
MX304020 544 HE800B 7 -3 290 -1 -993 -6 2 119 149 -7 -108 149 -181 21 29 8 157 307
MY302020 544 I1242035 9 -139 692 -2962 0 5 3 68 -145 -61 4 11 8 260 67
MZ304010 544 B060640 -125 536 -7937 1892 444 1 4 61 144 -6 -67 144 -181 11 29 8 141 290
MZ304020 544 B060640 23 -330 6810 1084 -7 2

Figure G-4 Local analysis Joint 304020, inplace condition

107
Joint check - Lift - Master Module
Weather deck

INPUT
Node
J301040 MC MD MX1 MX2 MY MZ
Member MC251030 MD301040 MX201040 MX301040 MY301040 MZ301030
Section B040420 B040420 I0852035 I0852035 I0852035 B060640

RESULTS Material properties


UFmax Dim LC gm 1.15
0.87 2 fy 355 MPa

Equations:
HMX
MY 
MYMC  MYMD  MYMZ  FZMC  FZMD  FZMZ  ex  FXMC  FXMD  FXMZ    FXMY MYMY
2 t XZ.1.2 
2Tf.MY BMY  
HMY  Tf.MY  BMY Tf.MY
FXMX1 MYMX1 MZMX1 FYMY MXMY MZMY
sX.1T   sY.1T   
A MX W Y.MX W Z.MX A MY W Y.MY W Z.MY FYMX1 MXMX1
t YZ.1 
2Tf.MX BMX  
HMX  Tf.MX  BMX Tf.MX
FXMX2 MYMX2 MZMX2 FYMY MXMY MZMY
sX.2T    sY.2T    FYMX2 MXMX2
A MX W Y.MX W Z.MX A MY W Y.MY W Z.MY t YZ.2 
2Tf.MX BMX HMX  Tf.MXBMXTf.MX
FYMY MXMY MZMY FYMX1 FZMX1 MXMX1
FXMX1 MYMX1 MZMX1 sY.1B   
sX.1B   t YZ.7  
A MX W Y.MX W Z.MX
A MY W Y.MY W Z.MY 2Tf.MX BMX Tw.MX HMX HMX  Tf.MXBMXTf.MX
FYMY MXMY MZMY FYMX2 FZMX2 MXMX2
sY.2B    t YZ.8  
sX.2B 
FXMX2

MYMX2

MZMX2 A MY W Y.MY W Z.MY 2Tf.MX BMX Tw.MX HMX HMX  Tf.MXBMXTf.MX
A MX W Y.MX W Z.MX
FXMC  FXMD  FXMZ
FZMC  FZMD  FZMZ t XY.7.8B
MY
sX.7B 
FXMX1

MYMX1 sZ.7B
A weld

IY
L1  eX A weld

A MX W Y.MX
FZMC  FZMD  FZMZ MY
FXMX2 MYMX2 sZ.8B
A weld

IY
L2  eX
sX.8B  
A MX W Y.MX

Incoming beam - y-dir Continuous deck beam - x-dir Incoming beam - column Incoming beam - braces Section A-A (gusset)
Section I0852035 Section I0852035 Section B060640 Section B040420 L1 750 mm

HMY 800 mm HMX 800 mm HMZ 600 mm HMZ 400 mm L2 680 mm


BMY 500 mm BMX 500 mm BMZ 600 mm BMZ 400 mm T 50 mm
Tf-MY 35 mm Tf-MX 35 mm Tf-MZ 40 mm Tf-MZ 20 mm s 30.0 mm (Part. pen. w eld)
Tw-MY 20 mm (1) Tw-MX 20 mm Tw-MZ 40 mm Tw-MZ 20 mm ex 35.0 mm
a 6.0 mm A MX 4.96E+04 mm2 A MZ 8.96E+04 mm2 A MZ 3.04E+04 mm2 A 8.58E+04 mm2
A MY 4.96E+04 mm2 Wx-MX 8.12E+05 mm3 Wx-MZ 2.51E+07 mm3 Wx-MZ 5.78E+06 mm3 Iy 1.46E+10 mm4
Wy-MY 1.44E+07 mm3 Wy-MX 1.44E+07 mm3 Wy-MZ 1.41E+07 mm3 Wy-MZ 3.28E+06 mm3
Wz-MY 2.92E+06 mm3 Wz-MX 2.92E+06 mm3 Wz-MZ 4.81E+06 mm3 Wz-MZ 1.07E+06 mm3
Figure G-5 Local analysis Joint 301040, lifting condition

108
Joint check - Lift - Master Module
Intermediate deck

INPUT
Node
J304030 MX1 MX2 MY MZ1 MZ2
Member MX254030 MX304030 MY302030 MZ304020 MZ304030
Section HE800B HE800B I0852035 B060640 B060640

RESULTS Material properties


UFmax Dim LC gm 1.15
1.00 2 fy 355 MPa

Equations:

FYMY MXMY MZMY FZMZ1 MXMZ1 MYMZ1


FXMX2 MYMX2 MZMX2 sy.2T  
sx.1T    sz.1B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMZ2 MZMY FZMZ1 MXMZ1 MYMZ1
FXMX2 MYMX2 MZMX2 sy.4T  
sx.2T    sz.2B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMY MZMY FZMZ1 MXMZ1 MYMZ1
FXMX1 MYMX1 MZMX1 sy.2B  
sx.3T   sz.3B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMY MZMY
FXMX1 MYMX1 MZMX1 sy.4B   FZMZ1 MXMZ1 MYMZ1
sx.4T   A MY W y.MY W Z.MY sz.4B  
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ

FZMZ2 MXMZ2 MYMZ2 FXMZ2 FYMZ2 MZMZ2


FXMX2 MYMX2 MZMX2 sz.1T   
sx.1B    t xy.1.2.3.4.T.  
A Mx W y.MX W Z.MX
A Mz W y.MZ W Z.MZ 2Tf.MZ BMZ 2.Tf.Mz HMZ HMZ2  Tf.MZ2 BMZ Tf.MZ
FZMZ2 MXMZ2 MYMZ2
FXMX2 MYMX2 MZMX2 sz.2T    FXMZ1 FYMZ1 MZMZ1
sx.2B    A Mz W y.MZ W Z.MZ t xy.1.2.3.4.B.  
A Mx W y.MX W Z.MX 2Tf.MZ BMZ 2.Tf.Mz HMZ HMZ2  Tf.MZ1 BMZ Tf.MZ
FZMZ2 MXMZ2 MYMZ2
FXMX1 MYMX1 MZMX1 sz.3T   
sx.3B   A Mz W y.MZ W Z.MZ FXMY MYMY FZMY
A Mx W y.MX W Z.MX t xz.2.4.  
2Tf.MY BMY HMY  Tf.MY BMY TfMY HMY tw.MY
FXMX1 MYMX1 MZMX1 FZMZ2 MXMZ2 MYMZ2
sx.4B   sz.4T   
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ FYMX2 MXMX2 FZMX2
syz.1.2.  
2Tw.MY BMX HMX  Tf.MX BMY Tf.MX HMX twMX

FYMX1 MXMX2 FZMX1


syz.3.4.  
2Tw.MX BMX HMX  Tf.MX BMX Tf.MX HMX tw.MX

Incoming beam - y-dir Continuous deck beam - x-dir Incoming beam - column
Section I0852035 Section HE800B Section B060640
HMY 800 mm HMX 800 mm HMZ 600 mm
BMY 500 mm BMX 300 mm BMZ 600 mm
Tf-MY 35 mm (2) Tf-MX 33 mm Tf-MZ 40 mm (2)
Tw-MY 20 mm (1) Tw-MX 17.5 mm Tw-MZ 40 mm (2)
a 5.0 mm A MX 3.26E+04 mm2 A MZ 8.96E+04 mm2
A MY 4.96E+04 mm2 Wx-MX 4.86E+05 mm3 Wx-MZ 2.51E+07 mm3
Wy-MY 1.44E+07 mm3 Wy-MX 8.73E+06 mm3 Wy-MZ 1.57E+07 mm3
Wz-MY 2.92E+06 mm3 Wz-MX 9.92E+05 mm3 Wz-MZ 1.57E+07 mm3

Note (1):
Weld at w eb is assumed to carry shear only
Note (2):
Part pen w eld

Top flange Bottom flange Shear stresses Von-Mises


Member LoadC SctNam Fx Fy Fz Mx My Mz Hot spot sx-T sy-T sz-T sx-B sy-B sz-B tyz txz txy-T sj-T sj-B tfill UF
(kN) (kN) (kN) (kNm) (kNm) (kNm) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa)
MX254030 2 HE800B -245 1 -70 0 208 -1 1 27 -65 -41 164 0 13 85 189 1.00
MX304030 2 HE800B 261 1 5 0 -298 1 2 25 275 212 -43 -265 -57 0 83 13 268 260
MY302030 2 I0852035 0 247 1326 -3901 -1 0 3 17 -65 -30 176 5 13 308 194
MZ304020 2 B060640 -24 377 5326 1733 93 0 4 15 275 212 -32 -265 -45 5 83 13 276 270
MZ304030 2 B060640 0 -646 -6588 2169 0 0

Figure G-6 Local analysis Joint 304020 , lifting condition

109
Joint check - Lift - Master Module
Lower deck

INPUT
Node
J504020 MX1 MX2 MY MZ1 MZ2
Member MX454020 MX504020 MY502020 MZ504010 MZ504020
Section HE800B HE800B I1252035 B040440 B040440

RESULTS Material properties


UFmax Dim LC gm 1.15
1.07 2 fy 355 MPa

Equations:

FYMY MXMY MZMY FZMZ1 MXMZ1 MYMZ1


FXMX2 MYMX2 MZMX2 sy.2T  
sx.1T    sz.1B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMZ2 MZMY FZMZ1 MXMZ1 MYMZ1
FXMX2 MYMX2 MZMX2 sy.4T  
sx.2T    sz.2B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMY MZMY FZMZ1 MXMZ1 MYMZ1
FXMX1 MYMX1 MZMX1 sy.2B  
sx.3T   sz.3B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMY MZMY
FXMX1 MYMX1 MZMX1 sy.4B   FZMZ1 MXMZ1 MYMZ1
sx.4T   A MY W y.MY W Z.MY sz.4B  
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ

FZMZ2 MXMZ2 MYMZ2 FXMZ2 FYMZ2 MZMZ2


FXMX2 MYMX2 MZMX2 sz.1T   
sx.1B    t xy.1.2.3.4.T.  
A Mx W y.MX W Z.MX
A Mz W y.MZ W Z.MZ 2Tf.MZ BMZ 2.Tf.Mz HMZ HMZ2  Tf.MZ2 BMZ Tf.MZ
FZMZ2 MXMZ2 MYMZ2
FXMX2 MYMX2 MZMX2 sz.2T    FXMZ1 FYMZ1 MZMZ1
sx.2B    A Mz W y.MZ W Z.MZ t xy.1.2.3.4.B.  
A Mx W y.MX W Z.MX 2Tf.MZ BMZ 2.Tf.Mz HMZ  
HMZ2  Tf.MZ1  BMZ Tf.MZ
FZMZ2 MXMZ2 MYMZ2
FXMX1 MYMX1 MZMX1 sz.3T   
sx.3B   A Mz W y.MZ W Z.MZ FXMY MYMY FZMY
A Mx W y.MX W Z.MX t xz.2.4.  
2Tf.MY BMY HMY  Tf.MY BMY TfMY HMY tw.MY
FXMX1 MYMX1 MZMX1 FZMZ2 MXMZ2 MYMZ2
sx.4B   sz.4T   
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ FYMX2 MXMX2 FZMX2
syz.1.2.  
2Tw.MY BMX  
HMX  Tf.MX  BMY Tf.MX HMX twMX

FYMX1 MXMX2 FZMX1


syz.3.4.  
2Tw.MX BMX HMX  Tf.MX BMX Tf.MX HMX tw.MX

Incoming beam - y-dir Continuous deck beam - x-dir Incoming beam - column
Section I1252035 Section HE800B Section B040440
HMY 1200 mm HMX 800 mm HMZ 400 mm
BMY 500 mm BMX 300 mm BMZ 400 mm
Tf-MY 35 mm (2) Tf-MX 33 mm Tf-MZ 40 mm (2)
Tw-MY 20 mm (1) Tw-MX 17.5 mm Tw-MZ 40 mm (2)
a 5.0 mm A MX 3.26E+04 mm2 A MZ 5.76E+04 mm2
A MY 5.76E+04 mm2 Wx-MX 4.86E+05 mm3 Wx-MZ 1.04E+07 mm3
Wy-MY 2.38E+07 mm3 Wy-MX 8.73E+06 mm3 Wy-MZ 6.30E+06 mm3
Wz-MY 2.92E+06 mm3 Wz-MX 9.92E+05 mm3 Wz-MZ 6.30E+06 mm3

Note (1):
Weld at w eb is assumed to carry shear only
Note (2):
Part pen w eld

Top flange Bottom flange Shear stresses Von-Mises


Member LoadC SctNam Fx Fy Fz Mx My Mz Hot spot sx-T sy-T sz-T sx-B sy-B sz-B tyz txz txy-T sj-T sj-B tfill UF
(kN) (kN) (kN) (kNm) (kNm) (kNm) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa)
MX454020 2 HE800B 504 1 -321 1 -670 -2 1 -61 -263 97 165 22 13 242 150 1.07
MX504020 2 HE800B -504 1 -307 1 690 2 2 -66 116 193 92 -115 -251 22 54 13 253 317
MY502020 2 I1252035 0 40 1304 -2755 0 0 3 -59 -260 94 161 23 13 330 147
MZ504010 2 B040440 5 339 -2619 1311 -14 0 4 -64 117 196 90 -115 -256 23 54 13 253 319
MZ504020 2 B040440 -3 -407 1943 1436 -8 0

Figure G-7 Local analysis Joint 504020, lift condition

110
Joint check - Lift - Master Module
Intermediate deck

INPUT
Node
J504030 MX1 MX2 MY MZ1 MZ2
Member MX404030 MX504030 MY502030 MZ504020 MZ504030
Section HE800B HE800B I0852035 B040440 B040440

RESULTS Material properties


UFmax Dim LC gm 1.15
1.07 2 fy 355 MPa

Equations:

FYMY MXMY MZMY FZMZ1 MXMZ1 MYMZ1


FXMX2 MYMX2 MZMX2 sy.2T  
sx.1T    sz.1B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMZ2 MZMY FZMZ1 MXMZ1 MYMZ1
FXMX2 MYMX2 MZMX2 sy.4T  
sx.2T    sz.2B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMY MZMY FZMZ1 MXMZ1 MYMZ1
FXMX1 MYMX1 MZMX1 sy.2B  
sx.3T   sz.3B  
A MY W y.MY W Z.MY A Mz W y.MZ W Z.MZ
A Mx W y.MX W Z.MX
FYMY MXMY MZMY
FXMX1 MYMX1 MZMX1 sy.4B   FZMZ1 MXMZ1 MYMZ1
sx.4T   A MY W y.MY W Z.MY sz.4B  
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ

FZMZ2 MXMZ2 MYMZ2 FXMZ2 FYMZ2 MZMZ2


FXMX2 MYMX2 MZMX2 sz.1T   
sx.1B    t xy.1.2.3.4.T.  
A Mx W y.MX W Z.MX
A Mz W y.MZ W Z.MZ 2Tf.MZ BMZ 2.Tf.Mz HMZ  
HMZ2  Tf.MZ2  BMZ Tf.MZ
FZMZ2 MXMZ2 MYMZ2
FXMX2 MYMX2 MZMX2 sz.2T    FXMZ1 FYMZ1 MZMZ1
sx.2B    A Mz W y.MZ W Z.MZ t xy.1.2.3.4.B.  
A Mx W y.MX W Z.MX 2Tf.MZ BMZ 2.Tf.Mz HMZ HMZ2  Tf.MZ1 BMZTf.MZ
FZMZ2 MXMZ2 MYMZ2
FXMX1 MYMX1 MZMX1 sz.3T   
sx.3B   A Mz W y.MZ W Z.MZ FXMY MYMY FZMY
A Mx W y.MX W Z.MX t xz.2.4.  
2Tf.MY BMY HMY  Tf.MY BMYTfMY HMY tw.MY
FXMX1 MYMX1 MZMX1 FZMZ2 MXMZ2 MYMZ2
sx.4B   sz.4T   
A Mx W y.MX W Z.MX A Mz W y.MZ W Z.MZ FYMX2 MXMX2 FZMX2
syz.1.2.  
2Tw.MY BMX  
HMX  Tf.MX  BMY Tf.MX HMX twMX

FYMX1 MXMX2 FZMX1


syz.3.4.  
2Tw.MX BMX HMX  Tf.MXBMXTf.MX HMX tw.MX

Incoming beam - y-dir Continuous deck beam - x-dir Incoming beam - column
Section I0852035 Section HE800B Section B040440
HMY 800 mm HMX 800 mm HMZ 400 mm
BMY 500 mm BMX 300 mm BMZ 400 mm
Tf-MY 35 mm (2) Tf-MX 33 mm Tf-MZ 40 mm (2)
Tw-MY 20 mm (1) Tw-MX 17.5 mm Tw-MZ 40 mm (2)
a 5.0 mm A MX 3.26E+04 mm2 A MZ 5.76E+04 mm2
A MY 4.96E+04 mm2 Wx-MX 4.86E+05 mm3 Wx-MZ 1.04E+07 mm3
Wy-MY 1.44E+07 mm3 Wy-MX 8.73E+06 mm3 Wy-MZ 6.30E+06 mm3
Wz-MY 2.92E+06 mm3 Wz-MX 9.92E+05 mm3 Wz-MZ 6.30E+06 mm3

Note (1):
Weld at w eb is assumed to carry shear only
Note (2):
Part pen w eld

Top flange Bottom flange Shear stresses Von-Mises


Member LoadC SctNam Fx Fy Fz Mx My Mz Hot spot sx-T sy-T sz-T sx-B sy-B sz-B tyz txz txy-T sj-T sj-B tfill UF
(kN) (kN) (kN) (kNm) (kNm) (kNm) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa) (MPa)
MX404030 2 HE800B -31 0 54 -1 -179 0 1 -21 -206 19 175 4 12 198 168 1.07
MX504030 2 HE800B 25 0 56 -1 176 0 2 -21 172 178 20 -173 -234 4 47 12 213 244
MY502030 2 I0852035 0 -24 754 -2490 0 0 3 -22 -210 19 172 4 12 331 165
MZ504020 2 B040440 3 407 -1787 1289 -9 0 4 -21 172 174 20 -173 -237 4 47 12 212 247
MZ504030 2 B040440 3 -378 925 1209 11 0

Figure G-8 Local analysis Joint 501030, lift condition

111

You might also like