Usb Fast Charge Tester
Usb Fast Charge Tester
2、Overview 01
3、Safety precautions 01
4、Performance description 02
4.0.1 Voltage and Current 02
4.0.2 Fast charge trigger 03
5、Structure appearance 03
6、Technical index 04
7、Main page 05
7.0.1 Concise page 05
7.0.2 monitoring page 05
9、Energy statistics 09
9.0.1 Energy statistics 09
9.0.2 Battery capacity calculation 10
10.0.3 PD Converter 13
10.0.4 USB-C-E-Marker 13
11、Settings 15
11.0.1 General 16
11.0.2 Record 16
11.0.3 Trigger 17
11.0.4 System 17
11.0.5 About 17
2、Overview
The FNB58USB tester is a high-reliability, high-safety USB voltage andcurrent
detection meter and a mobile communication terminal fast chargingtrigger.It has a
2.0-inch full-color ultra-wide viewing angle TFT LCD display, integrated USB-A,
Micro-USB, Type-C interface. Use external 16-bit ADC, PD protocol physical chip. It can
be used to measure the power supply or power consumption of products such as USB
interfaces, mobile phone chargers, and U disks; it can be used to measure the charging
power of mobile phones and the input and output of mobile power supplies; it can be
used to test the fast charging protocol of chargers.
This instruction manual includes relevant safety information,warningtips and
solutions to common abnormal situations. Please read the relevantcontent carefully
and strictly abide by all warnings and precautions.
3、Safety precautions
● Do not connect the monitoring interface to a power supply exceeding 28V;
● Do not connect the PC connection port to a power source exceeding 16v;
● Only one pair of monitoring interfaces (one input port,one outputport) can work at
the same time. When there is a pair of monitoringinterfaces working, it is forbidden
to connect to the equipment onother monitoring interfaces. (Except the PC
connection port, the PCport can be connected to an external power supply)
● When using the fast charge trigger module,please do not connect equipment that
cannot withstand high voltage to any monitoring interface;
● After using the PD trigger/monitor/conversion/read E-Marker cablefunction,please
turn the PD communication switch in the lower rightcorner back to the OFF position;
● Do not charge the phone after the fast charge is triggered, Therefore,the phone is
damaged,the manufacturer is not responsible for any damage to the phone.
1
4、Performance description
4.0.4 Miscellaneous
l.Record of startup time; 4.PD monitor;
2.Onboard temperature measurement; 5.Analog DASH cable;
3.Gravity sensor,automatically switch 6.Apple 2.4A acceleration;
the display direction;
2
5、Structure appearance
l.Input monitoring port: USB-A,5-PIN male;
2.Input monitoring port: TYPE-C,24-PIN female socket;
3.Input monitoring port: Micro-USB,5-PIN female socket;
4.output monitoring port: TYPE-C,24-PINfemale socket;
5.PD communication switch;
6.output monitoring port: USB-A,5-PINfemale;
7.touch switch: BACK button;
8.Multi-function switches: left button,middle button,rightbutton;
9.PC connection port: Micro-USB,5-PIN female socket
② ③ ④ ⑤
① ⑥
⑨ ⑧ ⑦
3
6、Technical index
℃ 1℃ ±(1.2%+3)
Equipment
temperature
℉ 1℉ ±(1.2%+4)
Equipmnt 99d23h59min59s 1s
running time
Record time 99d23h59min59s 1s
4
7、Main page
●Except for special instructions,the left and right buttons switchpages/menus,the
middle button confirms,and the BACK button cancels/returns.
●Long press the BACK button to turn off the screenbacklight,all pages are valid.
5
7.0.3 Waveform page
Application
●Fast Charge
●Statistics
●Toolbox
●Settings
8、Fast Charge
In the application interface, press the middle button to enter the fast charging
application. When entering the fast charging application, a warning will pop up. Please
read carefully and press the middle button to confirm the entry.
After entering, use the left and right keys to select options as follows:
1.Automatic detection 6.SCP
2.PD Trigger 7.AFC
3.QC2.0 8.VOOC/WARP
4.QC3.0 9.SVOOC 1.0
5.FCP 10.SVOOC 2.0
6
8.0.1Automatic detection
8.0.2 PD Trigger
●Take the picture as an example, the picture shows a charger sending a message, a total
of 7 files, its the 1st, 2nd, 3rd, 4th, and 5th gears are fixed voltage gears, currently
adjustable the window is gear adjustment, you can select the gear by the left and right
keys, such as when in the voltage/current window, the voltage/current can be adjusted.
●Click BACK to pop up the exit/return menu selection window.
7
8.0.3 QC 2.0 Trigger
8
8.0.7 AFC Trigger
9、Energy statistics
In the application interface, select energy statistics and press the middle button to
enter the statistics page. The function options are as follows, and the left and right
buttons are used to select Press the middle button to enter each function option
●Energy Statistics (Statistics List)
●Battery capacity calculation (calculate battery capacity)
●Offline record (view offline record curve)
9
9.0.2 Battery capacity calculation
After pressing the middle button to enter, press the middle button
again to select "Start Offline Recording/Clear Offline Recording"
10
10、Toolbox
In the application interface, select the toolbox and press the middle button to
enter the toolbox page. The function options are as follows. Select the left and
right buttons and press the middle button to enter each function option.
FNB58 uses the differential pressure method to measure the internal resistance of
the cable, which needs to be used with a constant current load.
Click the middle button: use the current voltage and current value as the reference
value.
Measurement steps
1. Connection method: charger + FNB58 + constant
current load (the current is adjusted to about
0.5-1A), press the middle button to record the
reference value.
2. Connection method: charger + cable + FNB58 +
constant current load (the current should be
adjusted to about 0.5-1A, which should be similar to the current when the reference
value was recorded), the system automatically calculates the internal resistance of the
cable.
11
10.0.2 PD Listener
When using PD listener,Need to turn the PD communication switchtoON,And use a
power supply not greater than 16V (usually 5V) and a Micro-USB cable,Connect the PC
online port,Provide external power.
Use the PD listener function,Need 2 C-C cables,Connect the chargerand PD electrical
appliances from the Type-CIN interface and Type-COUTinterface respectively.When
the connection is normal and the PD protocoltriggered by the PD consumer is
captured,The page is represented asshown below.
Note:
1 Open the settings menu -> trigger -> block PDCRC, you can turnoffthe monitoring of
CRC.
2 For the meaning of various messages in the PD protocol, pleasereferto the relevant
information..
12
10.0.3 PD Converter
●This function is used for only QC2.0 charger, But want to supply power to
PDappliances.
●Before use, Switch the PD communication switch to ON, Then enter the PDprotocol
conversion mode,after entering,Plug in PD appliances, You can performPD fast
charge.
●In this mode,C1ick the middle button and use the left and right buttons tochange the
maximum power of packets sent by the PD.When changing power,Becareful not to
exceed the charger power to avoid unnecessary damage.Afterchanging the power,
you must click the middle button to confirm.
●Set 5v when no device is connected,Avoid high-voltage damage to mobilephones
that do not support high-voltage when plugged in.
●QC2.0 only B type charger supports 20v trigger, So when the PD appliancerequests
20V voltage, The tester will detect whether the charger successfullytriggers
QC2.0-20V,If it does not reach 20V, The tester will cancel the 20V gear,And resend the
Caps broadcast.
10.0.4 USB-C-E-Marker
E-Marker cable refers to a cable with an E-Marker chip in the Type-C interface,If the
interface does not contain E-Marker chip, The packets from thePD charging head cannot
exceed 3A current, And only use the E-Marker cable to trigger the PD protocol, The
current can exceed 3A.
When using the USB-C electronic label,Except that the Type-C interface cannot be used
for power supply,PC port,USB-A,Micro-USB interface can all be usedforpowersup-
ply.The PD communication switch needs to be turned ON.
13
After entering this function,From the output Click the middle button to
Type-C interface,Plug in thecable,You can switch to the figure below:
read the message,As shown below:
The two pictures above,The picture shows the parsed data,The secondpicture is the
original data,Users can consult the relevant informationof the PD agreement by
themselves,Do your.
Enter this function,Plug in the DASH cable,You can read the chip-related data,As shown
below:
14
●If,The phone normally needs to use a USB-A->Type-C DASH cable,Butthere is no such
thread in hand,Only FNB48 tester and a C-C cable,Butwantto trigger VOOC/WARP
flash charge,At this time, the function of simulating DASH cable can be started,And
use the C-C cable to connecttothe phone, You can perform VOOC/WARP flash
charging.
Note: Since this method does not use the original data cable forcharging, The
charging power is largely affected by the C-C line,If theimpedance of the C -C
line is high,Then the charging power will be reduced a lot.
When the Apple device detects that the charging head D+ and D- are2.7V,To charge at
5V-2.4A,This function sets D+ and D- to 2.7V.
11、Settings
In the application interface, select the toolbox and press the middle button to enter the
toolbox page. The function options are as follows. Select the left and right buttons and
press the middle button to enter each function option.
15
11.0.1 General
Left and right keys to select and press the middle key to enter various function
options.
Set the screen brightness, the adjustable range is 1-100.
●Display brightness:
Set the standby screen brightness,Adjustable range 0-100
●Standby brightness:
level, whensetto 0,Enter the standby state and turn off the screen directly.
Set the standby time, the last time you operate the button to
●Standby time:
starttiming,Reach the standby time,Enter the standby state
●Refresh rate: select slow-medium-fast.
The onboard temperature can be displayed as°C/℉.
●Temperature symbol:
Currently only Chinese/English is supported. Due to the charactersizep-
●Language:
roblem, English will be displayed in the Chinese system, which is anormalphenom-
enon.
Turn on to automatically rotate the screen.
●Gravity direction recognition:
Turn on/off the boot page.
●Boot page:
●Key Tone: Turn on/off the key tone.
11.0.2 Record
Left and right keys to select and press the middle key to enter various function
options.
Set the recording time of the voltage and current curve,Max-
●Curve recording time:
imum9hours,Set to no time record.Every time you change the configuration,the-
curve will be cleared to 0.
When the current ≥ the threshold,To carry out
●Statistical current threshold:
statistics on capacity, energy, and time,Setting range 0-7A.
Set to no time,No time limit,Until the statistics reach the
●Energy statistics time:
maximumvalue. After setting the time,When the statistical time reachestheset
value, the statistics will automatically stop.
Clear all recorded data,Including offline curves,Energy statistics.
●Clear all records:
16
11.0.3 Trigger
Left and right keys to select and press the middle key to enter various function
options.
●Trigger time:Set the time to manually trigger the protocol.
●Monitor mask PD CRC:After opening,When PD is monitoring,CRC messages can be
masked,Off by default.
●Boot simulation DASH:After it is turned on, turn on the analog DASH cable function
atboot,which is turned off by default
●Boot analog Apple 2.4A accelerator:After opening,Turn on the Apple 2.4A
acceleration function whenbooting,Off by default.
11.0.4 System
Factory reset.
11.0.5 About
17
Production information
Manufacturer
Shenzhen FNIRSI Technology Co., Ltd
Address
8th Floor, West of Building C, Weihuada Industrial Park,Dalang Street,
Longhua District, Shenzhen,Guangdong Province
Contact details
0755-83242477
Website
www.fnirsi.cn