0% found this document useful (0 votes)
88 views

Section6 - Bill of Quantities

This document provides a lot detail for construction works on a jetty in Sandwip, Bangladesh. It includes 3 sentences summarizing key information: The lot description is for the construction of an RCC jetty and allied works at Sandwip, Chattogram under a project to establish jetties and infrastructure at several locations in Bangladesh. A bill of quantities is provided listing 9 items for civil works on the jetty structure including site facilities, subsoil investigation, transportation, and equipment hire. Payments will be made for completed portions of the works on a percentage basis according to the contract terms.

Uploaded by

Sajib Hossain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
88 views

Section6 - Bill of Quantities

This document provides a lot detail for construction works on a jetty in Sandwip, Bangladesh. It includes 3 sentences summarizing key information: The lot description is for the construction of an RCC jetty and allied works at Sandwip, Chattogram under a project to establish jetties and infrastructure at several locations in Bangladesh. A bill of quantities is provided listing 9 items for civil works on the jetty structure including site facilities, subsoil investigation, transportation, and equipment hire. Payments will be made for completed portions of the works on a percentage basis according to the contract terms.

Uploaded by

Sajib Hossain
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 36

Lot Detail

Lot No. : Works W-7


Lot Description Construction of RCC Jetty with allied works at Sandwip, Chattogram under the project of "Establishment of Jetties and
Infrastructure at Mirsarai & Sandwip in Chittagong, Subrang-Jaliar Dwip at Teknaf and Sonadia Dwip at Cox�??�?¢??s
:
Bazar".

Bill of Quantities

Table
Bill of Quantities
Name :
Unit Total Total
Item Unit Price Price Price Price
Item Group Code Description of Item Measurement Quantity
no. (if Unit In figures (BDT) In In In
any) Words Figures Words
(BDT) (BDT) (BDT)
1 PART-A. 1 Erection and maintenance of LS 1.00
Civil site office and removal the
Works: same after completion of work
Jetty in accordance with the
Structure conditions of contract. In
addition to the office required
for his own use, the Contractor
shall provide and maintain
furnished field office for the use
of the Engineer and his staff.
The field office is to have a
concrete floor, adequate
foundation, brick walls, false
ceiling of hard board with
seasoned Garjan wood frame
and painted, and all windows
are to be glazed and provided
with steel grill. Outside and
inside wall surface are to be
painted on plaster acceptable
to the Engineer. The field office
shall be maintained in a secure
and watertight condition with
full utility services connected
and maintained by the
Contractor until the completion
of the contract and shall be
provided with electricity,
running water and sewerage.
All doors shall be fitted with
approved locks and windows
shall be provided with
screen/blinds. Before
construction the Contractor
shall submit plans and drawings
showing proposed details and
location for the field office,
including foundations, access
roads, shades, layout of
electrical and water supply and
hard standings thereto for the
approval of the engineer.The
Engineer may require revision
of the plans prior to giving
approval for construction. The
Contractor shall also submit
details proposed furniture,
fittings and other items of
equipment and plant to the
engineer for approval. These
items shall be of the standard
quality suitable for site. The
office, complete with
furnishings, fittings, access
roads and hard standings shall
be ready for occupation by the
Engineer within 28 days of the
date when the Contractor first
occupies the site. The
Contractor will provide day and
night guards and a tea boy for
the field office. At the end of
the project all materials,
equipment and plant, furniture,
fittings recovered from
dismantling the office and
removing access road will be
the property of the Contractor.
No interim payment shall be
certified unless Engineer's
office with required facilities
are constructed and accepted
by the Engineer.(This is a time
related item. Proportionate
payment for this item shall be
made distributing in each bill on
the basis of percentage
progress of the whole works
under contract) Engineer's site
office of minimum 15 sqm plinth
area with providing furniture,
first aid-box, safety helmet,
level / total station,
consumables, stationeries etc.
2 PART-A. 2 Supply and installation of site LS 1.00
Civil laboratory and remove the
Works: same after completion of the
Jetty work of floor area of 100 m2 .
Structure
3 PART-A. 3 Providing and maintenance Each 1.00
Civil window type 1800 BTU AC
Works: (Air-Cooler) for Engineer's
Jetty office and remove after
Structure completion of contract.
4 PART-A. 4 Providing and maintenance one sqm 2.00
Civil project profile signboards of
Works: the size not exceeding 1 m x 2
Jetty m, to be placed at a suitable
Structure place of the site including
submission of proposals for the
materials of the signboards and
text layout to the Engineer-in-
charge for approval which will
be positioned as directed by
the Engineer-in-charge and
removing the same on
completion of the works or as
instructed by the Engineer-in-
charge.
5 PART-A. 5 (a) Sub-soil investigation by 100 per bore hole 10.00
Civil mm dia wash boring and / or by
Works: CPT, DCP etc. including
Jetty collecting disturbed and
Structure undisturbed soil samples in
numbers as required for
classification of soil, conducting
SPT, stratification of layers,
analysing physical parameters
of soils like Atterberg limits,
specific gravity, gain size
distribution(by wet seive,
hydrometer if required) ,ground
water table location, direct
shear test, unconfined
compression test, unit
weight(dry/weight), natural
moisture content ; c - ф values
and other strength parameters
to ascertain bearing capacity ,
skin friction, end bearings etc
at every 1.5 m interval as per
respective national/international
standards and entering all
these data and information in
necessary tables and graphs
and finally furnishing them in the
form of standard sub-soil
investigation report duly signed
by competent Engineer and
exploratory office.
Bore hole depth from 0 to 20 m
6 PART-A. 5 (b) Additional charge for bore hole meter 100.00
Civil depth above 20.0 m and upto
Works: 30.0 m
Jetty
Structure
7 PART-A. 6 Providing transport facilities for Month 24.00
Civil quality control part of project
Works: which includes carrying test
Jetty samples, work samples, report
Structure collection & emergency
services of project including
cost of fuel driver, maintenance
etc. (Total duration is 1/2 of the
initial contract duration or
contract completion time
whichever is less).
8 PART-A. 7 ''Hiring of speed boat/Engine hr 2000.00
Civil boat (With roof cover, life
Works: jacket) in a tip top condition
Jetty during travelling to different
Structure field offices or to different
construction sites or any other
official use, meeting, discussion
or any other matters including
driver (minimum 5 years of
driving experience having valid
driving license) and necessary
maintenance of vehicle etc.
complete as per direction of
Engineer in charge.
Speed Boat''
9 PART-A. 8 ''Cost of Fuel, Lubricant etc. hr 2000.00
Civil for Speed Boat/Engine Boat
Works: with roof cover, life jacket for
Jetty travelling to different field
Structure offices or to different
construction sites or any other
official use etc. complete as
per direction of Engineer in
charge.
Speed Boat''
10 PART-A. 9 (a) Supply & Installation of Pre- Rm 6348.00
Civil Stressed Hollow Concrete
Works: (PHC) piles including Pile Shoe
Jetty (1.5m long, made of 20mm
Structure thick MS plate, Fy=345MPa)
as per details shown in drawing
and specification. Rates shall
include all cost of procurement
upon satisfactory factory
acceptance test to
demonstrate required flexural
capacity (see DWG ) for at
least 1% of PHC piles (From
each shipment at least 2 piles
of each diameter shall be
tested up to specified cracking
moment and at least two piles
shall be tested up to failure )
and transportation/handling,
joint welding, pre-boring if
necessary, cutting the excess
for construction of pile cap,
hiring and/or operational cost
of appropriate equipment,
required burge/equipments,
survey and setting/positioning
operations all complete and
acceptable to the Engineer.
Before commencing driving
operation, Contractor shall
submit method statement for
carrying the driving operation
including sequence of driving to
the Engineer for approval.
However, Engineer's approval
shall not relieve the Contractor
of his responsibilities and
obligations under
contract.1000mm dia pile (max
45m long). Full length of the
pile shall be considered for
measurement and payment.
11 PART-A. 9 (b) 900mm dia pile (max 45m long) Rm 100.00
Civil
Works:
Jetty
Structure
12 PART-A. 10 Customs Duty of Pre-Stressed Rm 6348.00
Civil (a) Hollow Concrete (PHC) piles
Works: as per details shown in drawing
Jetty and specification. Rates shall
Structure include all cost of procurement
upon satisfactory factory
acceptance test to
demonstrate required flexural
capacity (see DWG) for at
least 1% of PHC piles (From
each shipment at least 2 piles
of each diameter shall be
tested up to specified cracking
moment and at least two piles
shall be tested up to failure )
and transportation/handling
including
CD/VAT/TAX/Surcharge/ any
other government duty, joint
welding, pre-boring if
necessary, cutting the excess
for construction of pile cap,
hiring and/or operational cost
of appropriate equipment,
survey and setting/positioning
operations all complete and
acceptable to the Engineer.
Before commencing driving
operation, Contractor shall
submit method statement for
carrying the driving operation
including sequence of driving to
the Engineer for approval.
However, Engineer's approval
shall not relieve the Contractor
of his responsibilities and
obligations under
contract.1000mm dia pile (max
45m long)
13 PART-A. 10 900mm dia pile (max 45m long) Rm 100.00
Civil (b)
Works:
Jetty
Structure
14 PART-A. 11 Arranging for pile integrity test Nos 142.00
Civil (PIT) for the pile for confirming
Works: the soundness of the pile
Jetty constructed. The PIT shall
Structure have to be done by an reliable
institution approved by the
Engineer.
15 PART-A. 12 Conducting static/high strain per test 10.00
Civil dynamic load test (pile in river)
Works: for the cast-in-situ concrete pile
Jetty providing required scaffolding,
Structure bracing, jacks, pressure test
gauge, kentledge and other
plants and equipment as per
standard practice and
procedures submission of load
test report and charts as per
standard practice, drawing,
specification and direction of
the Engineer-in-charge.
(Excluding the cost of piles).
The Contractor shall have to
arrange additional piles for
staging and load application.
The work methodology for
conducting for test shall have to
be approved by the Engineer.
High Strain Dynamic Load test
(ASTM D4945-12) for a load
of 700 Ton.
16 PART-A. 13 ''Test Pile (2 Nos): Rm 96.00
Civil Driving pre-cast pile of 350 mm
Works: x 350 mm cross section made
Jetty with shoe/ without shoe by
Structure Hydraulic static pile driver of
approx. 500 tonne (metric ton)
capacity; arranged with
necessary cranes, power
source, maintaining driving log
and record of pressure exerted
on piles driven in to desired RL
or capacity level ; complete in
all respect including handling of
piles, dressing & leveling of
site, way making, surveying,
layout setting etc ended with
the submission of pile driving
report in three copies duly
signed by professional engineer
and approved by the Engineer-
in-charge.
Full length of the pile shall be
considered for measurement
and payment.
''
17 PART-A. 14 ''Test Pile (2 Nos): Cum 11.76
Civil Casting of pre-cast pile with
Works: reinforced cement concrete
Jetty having minimum cement content
Structure relates to mix ratio 1:1.25:2.5,
minimum f'cr = 35 Mpa, and
satisfying specified
compressive strength f?c = 30
Mpa at 28 days on standard
cylinders as per standard
practice of Code
ACI/BNBC/ASTM & cement
conforming to BDS EN-197-1-
CEM-I (52.5 N) / ASTM-C 150
Type ? I, best quality coarse
sand (F.M.2.2), 20 mm down
well graded crushed stone
chips conforming to ASTM C-
33, mixing in standard mixture
machine and fed by standard
measuring boxes, including all
related works like screening
through proper sieves, cleaning
and washing, centering and
shuttering with M.S sheet, M.S
angle, F.I bar, nuts and bolts,
champering edges if so,
preparation of casting beds,
laying polythene there in,
placing reinforcement cages in
position, casting, compacting
by vibrators and tapered rods
as where necessary, curing for
28 days etc., cost of water,
electricity, all materials and
other charges, providing fitting
and fixing pile shoe in position,
tools, plants & equipments,
mobilization, demobilization,
labour, conducting laboratory
test of materials and concrete
etc. all complete as per design,
drawing and accepted by the
Engineer-in-charge. (Rate is
excluding the cost of
reinforcement and its
fabrication, binding, welding
and placing) 350 mm x 350 mm
size pre-cast pile (1:1.25:2.5)
with stone chips.''
18 PART-A. 15 ''Driving pre-cast pile of 350 Rm 130066.20
Civil mm x 350 mm cross section
Works: made with shoe/ without shoe
Jetty by Hydraulic static pile driver of
Structure approx. 500 tonne (metric ton)
capacity; arranged with
necessary cranes, power
source, maintaining driving log
and record of pressure exerted
on piles driven in to desired RL
or capacity level ; complete in
all respect including handling of
piles, dressing & leveling of
site, way making, surveying,
layout setting etc ended with
the submission of pile driving
report in three copies duly
signed by professional engineer
and approved by the Engineer-
in-charge.
Full length of the pile shall be
considered for measurement
and payment.''
19 PART-A. 16 Casting of pre-cast pile with Cum 15933.11
Civil reinforced cement concrete
Works: having minimum cement content
Jetty relates to mix ratio 1:1.25:2.5,
Structure minimum f'cr = 35 Mpa, and
satisfying specified
compressive strength f?c = 30
Mpa at 28 days on standard
cylinders as per standard
practice of Code
ACI/BNBC/ASTM & cement
conforming to BDS EN-197-1-
CEM-I (52.5 N) / ASTM-C 150
Type ? I, best quality coarse
sand (F.M.2.2), 20 mm down
well graded crushed stone
chips conforming to ASTM C-
33, mixing in standard mixture
machine and fed by standard
measuring boxes, including all
related works like screening
through proper sieves, cleaning
and washing, centering and
shuttering with M.S sheet, M.S
angle, F.I bar, nuts and bolts,
champering edges if so,
preparation of casting beds,
laying polythene there in,
placing reinforcement cages in
position, casting, compacting
by vibrators and tapered rods
as where necessary, curing for
28 days etc., cost of water,
electricity, all materials and
other charges, providing fitting
and fixing pile shoe in position,
tools, plants & equipments,
mobilization, demobilization,
labour, conducting laboratory
test of materials and concrete
etc. all complete as per design,
drawing and accepted by the
Engineer-in-charge. (Rate is
excluding the cost of
reinforcement and its
fabrication, binding, welding
and placing) 350 mm x 350 mm
size pre-cast pile (1:1.25:2.5)
with stone chips.
20 PART-A. 17 Labour for breaking head of Cum 196.76
Civil hardened cast in situ bored
Works: pile/pre-cast pile up to a
Jetty required length by any means
Structure but without damaging the rest
and removing the dismantled
materials such as concrete to a
safe distance including scraps
and cleaning concrete from
steel/M.S. rods, straightening
and bending of pile bars,
preparation and making
platform where necessary,
carrying, all sorts of handling,
stacking the same properly
after clearing, levelling and
dressing the situ and clearing
the bed etc. complete in all
respect and accepted by the
Engineer-in-charge.
(Measurement will be given for
the actual pile head volume to
be broken)
21 PART-A. 18 ''Static Load Test on pre-cast per test 1.00
Civil (a) pile:
Works: Conducting static load test as
Jetty per ASTM D1143 or equivalent
Structure standard for the cast-in-
situ/pre-cast pile providing
required scaffolding, bracing,
jacks, pressure test gauge,
loading unloading, Kentledge
and other plants and
equipments including staging,
mobilization, demobilization,
hire charge, gunny bags, sand
and filling sacs/gunny bags for
loading, record readings and
preparation of results in
standard forms and other
incidental charges as per
standard practice and
procedures including
submission of load test report,
furnishing all graph and chart
etc. complete in all respect
approved and accepted by the
Engineer-in-charge (Minimum
two cyclic loading; one at
service load and another cycle
at double the service load then
to continue loading till failure of
the pile). Before commencing
load test, contractor shall
submit method statement for
conducting load test to the
Engineer-in-charge for
approval. However, Engineer's
approval shall not relieve the
contractor of his responsibilities
and obligations under contract.
Load test and report shall be
conducted under the
supervision of a professional
Geotechnical Engineer
registered in BPERB or
geotechnical firm registerd in
PWD. Boring and pouring logs
/ driving logs of piles and
method statement shall be the
part of load test report.'' For
300 ton load
For first test at one site for one
testing set
22 PART-A. 18 For 2nd & additional tests at per test 14.00
Civil (b) same site for same testing set
Works:
Jetty
Structure
23 PART-A. 19 Layout of foundation in all kinds sqm 38175.00
Civil of soil/water for foundation
Works: including. layout, providing
Jetty center lines, local bench-mark
Structure pillars/piles, leveling, providing
necessary tools and plants/with
barge mounted total
station,cleaning the excavated
earth at a safe distance out of
the area enclosed by the layout
etc. all complete and accepted
by the Engineer, subject to
submit method statement of
carrying out layout /excavation
work to the Engineer for
approval. However, Engineer's
approval shall not relieve the
contractor of his responsibilities
and obligations under the
contract.
Layout and marking for
piles/jetty layout and where
necessary earthwork in
excavation in foundation
accepted by the Engineer.
[Plinth area of the structure
shall be considered for
measurement]
24 PART-A. 20 Reinforced cement concrete Cum 7580.02
Civil (a) works with minimum cement
Works: content relates to mix ratio
Jetty 1:1.5:3 having minimum f'cr =
Structure 30 MPa, satisfying a specified
compressive strength f?c = 25
MPa at 28 days on standard
cylinders as per standard
practice of Code
ACI/BNBC/ASTM, Cement
conforming to BDS EN-197-1-
CEM-I, 52.5N (52.5 MPa) /
ASTM-C 150 Type ? I, with
approved high range admixture
(complying specific type under
ASTM -C494) best quality
Sylhet sand or coarse sand of
equivalent F.M. 2.2 and 20 mm
down well graded stone chips
conforming to ASTM C-33,
making and placing shutter in
position and maintaining true to
plumb, making shutter water-
tight properly, placing
reinforcement in position;
mixing with standard mixer
machine with hopper, fed by
standard measuring boxes or
mixing in batching plant, casting
in forms, compacting by
vibrator machine and curing at
least for 28 days, removing
centering-shuttering after
specified time approved;
including cost of water,
electricity, testing charges of
materials and concrete
cylinders as required, cost of
all materials and other charges
etc. all complete, approved and
accepted by the Engineer-in-
charge. . The contractor shall
arrange depositing concrete in
pumpable condition from barge
mounted mixer truck (Rate is
excluding the cost of
reinforcement and its
fabrication, placing, binding etc.
and the cost of shuttering &
centering)
Individual & combined footing,
pile cap, raft/mat, floor slab
and foundation beam up to jetty
level
25 PART-A. 20 Pedestals, column, column Cum 86.73
Civil (b) capital, lift wall and RCC wall
Works: Ground floor
Jetty
Structure
26 PART-A. 20 Floor / roof slab, T-beam, L- Cum 14974.87
Civil (c) beam and rectangular beam,
Works: tie beam, lintel, stair case slab
Jetty and steps etc.
Structure
27 PART-A. 21 Centering and shuttering, sqm 23058.29
Civil (a) including strutting, propping
Works: with special arrangement as
Jetty per site need etc. (The
Structure formwork must be rigid enough
both in and out of plane, to
make the concrete surface true
to the designed shape and size
by using necessary MS sheets
of minimum 16 BWG, angles
of minimum size 50 mm x 50
mm x 6 mm, flat bars,,
structural steel joist, and
structural tubes of approved
grade and size etc.- the
contractor shall be responsible
to submit shop drawings of the
shuttering for approval of the
Engineer-in-charge) and
removal of form after hardening
of the concrete for:
Individual and combined
footing, pile cap etc
28 PART-A. 21 Pedestal, column, column sqm 375.76
Civil (b) capital, lift wall and wall
Works:
Jetty
Structure
29 PART-A. 21 T-beam, L-beam and sqm 37398.60
Civil (c) rectangular beam etc
Works:
Jetty
Structure
30 PART-A. 21 Floor and roof slab sqm 39256.08
Civil (d)
Works:
Jetty
Structure
31 PART-A. 21 Stair case slab and steps sqm 835.38
Civil (e)
Works:
Jetty
Structure
32 PART-A. 22 ''Picon Shutter / Scaffolding : sqm 16510.82
Civil Reinforced cement concrete
Works: shutter works using Picon set,
Jetty 12mm Garjan play, build & cast
Structure in specified module of different
sizes. Fixed in position using 08
(eight) 25~38mm GI /MS Pipe
/Box (Sampl as per
Engineering Office). Making
and placing shutter in position
and maintaining true to plumb,
making shutter water-tight
properly, placing reinforcement
in position, removing centering-
shuttering after specified time
approved; Shutter /props /
scafflding having designed &
calculated by contractor and
vatted by the engineer in
charge with all necessary
materials including but not
limited to welding,
straightening, finishing with zero
leak.

Measurement : Actual shutter


area will be calculated.
Mode of payment: Paymnet
will be in shutter area unit.''
33 PART-A. 23 Supplying,fitting fixing 6mm no 142.00
Civil thick steel plate on pile top all
Works: complete as per drawing and
Jetty direction of the engineer in
Structure charge .
34 PART-A. 24 Supplying, fabrication and fixing kg 6000692.12
Civil to detail as per design : ribbed
Works: or deformed bar reinforcement
Jetty for Reinforced cement
Structure concrete, produced and
marked in accordance with
ASTM A706 (or standard
subsequentley released from
BSTI) including straightening
and cleaning rust, if any,
bending and binding in position
with supply of G.I. wires,
conducting necessary
laboratory tests etc. (excluding
splices or laps) complete in all
respect and accepted by the
Engineer-in-charge
(Measurement shall be
recorded only on standard
mass per unit length of bars,
while dia of bars exceeds its
standard)
Grade 400 (RB 400 /RB
400W: complying ASTM A706
ribbed or deformed bar
produced and marked
according to Bangladesh
standard, with minimum yield
strength, fy (ReH)= 400 MPa
but fy not exceeding 450 MPa
and whatever is the yield
strength within allowable limit
as per BNBC/ ACI 318, the
ratio of ultimate tensile strength
fu to yield strength fy, shall be
at least 1.25 and minimum
elongation after fracture and
minimum total elongation at
maximum force is 16% and 8%
respectively : up to ground
floor.
35 PART-A. 25 ''Supplying of wooden ballah meter 25300.00
Civil (a) having an average diameter not
Works: less than 150 mm (without
Jetty barks) at one third distance
Structure from larger end with a minimum
end diameter of 100 mm for
retaining purpose and driving to
a depth as per design and
drawing by any method
including all arrangement for
staging, hoisting, carrying etc.
complete and accepted by the
Engineer-in-charge.
''
36 PART-A. 25 ''Palisading work by supplying sqm 15090.00
Civil (b) of bitumen drum sheet walling
Works: tied with 20 BWG G.I. wire
Jetty fixing the same with already
Structure driven borrak bamboo posts
with half split borrak bamboo
runners @ 450mm c/c
horizontally with iron nails, G.I
wire etc. all complete and
accepted by the Engineer-in-
charge. (Rate is excluding the
cost of bamboo post).
''
37 PART-A. 25 ''Supplying and fitting-fixing meter 25000.00
Civil (c) horizontal bracing in palisading
Works: with half split wooden ballah
Jetty having an average diameter not
Structure less than 150 mm with a
minimum end diameter of 100
mm @ 450 mm including supply
of iron nails, gazals etc.
complete approved and
accepted by the Engineer-in-
charge.
''
38 PART-A. 26 ''Site Cum 453750.00
Civil development/Improvement by
Works: carted earth or dredged sand,
Jetty sandy silt (free from any
Structure organic, foreign, environmental
hazardous substances) carried
by head or by truck or by any
other means including cost of
cutting or by dredging of sand,
sandy silt, all;
including local carrying, placing
the earth/sand, sandy silt in the
designated area, maintaining
slopes, breaking lumps,
levelling and dressing in layers
up to finished level etc. all
complete as per direction and
accepted by the engineer in
charge. By dredging including
necessary systems thereof.
''
39 PART-A. 27 ''Supplying at site U-shape hot M.ton 2862.00
Civil (a) rolled steel sheet pile of
Works: different
Jetty section of
Structure Phosphorus=0.04%(Maximum),
Sulphur = 0.04%
(Maximum), Tensile strength=
> 490 N/mm2 , Yield strength =
>296
N/mm2, Elongation =15%
(Minimum) including all taxes,
freights,
incidental charges etc.
complete as per direction of
the Engineer -incharge. U-
shape, hot- rolled steel sheet
pile width= 400mm to 600mm:
height= > 100mm, Thickness
>=10.5mm. (�0.50mm)
''
40 PART-A. 27 ''Driving steel sheet piles of sqm 19080.00
Civil (b) various sections and weights of
Works: any type of
Jetty soil, by monkey hammer
Structure including handling and placing in
position,
staging and supplying of all
equipments like monkey
hammer, pully,
rope, bamboo, bullah etc.
including correcting leaning
beyond
tolerance & other defects and
any other incidental cost etc.
complete
(measurement will be taken on
projected width x height) as per
direction of Engineer in charge.
U-type or any other type : Upto
4.50 m depth.
''
41 PART-A. 27 ''Lifting steel sheet piles of any sqm 19080.00
Civil (c) section and weights from any
Works: type of
Jetty soil by mechanical device
Structure including handling and placing in
stacks
etc. complete (measurement
will be taken on projected width
x
height)including supply of all
equipments etc. complete as
per
direction of Engineer in charge.
''
42 PART-A. 28 Earth work in excavation in all Cum 750.00
Civil (a) kinds of soil for foundation
Works: trenches including. layout,
Jetty providing center lines, local
Structure bench-mark pillars, leveling,
ramming and preparing the
base, fixing bamboo spikes and
marking layout with chalk
powder, providing necessary
tools and plants, protecting and
maintaining the trench dry etc.,
stacking, cleaning the
excavated earth at a safe
distance out of the area
enclosed by the layout etc. all
complete and accepted by the
Engineer, subject to submit
method statement of carrying
out excavation work to the
Engineer for approval.
However, Engineer's approval
shall not relieve the contractor
of his responsibilities and
obligations under the contract.
i) Earthwork in excavation in
foundation trenches up to 1.5 m
depth and maximum 10 m lead:
in very stiff (hard) clayey soil/
rubbish etc.
43 PART-A. 28 i) Earthwork in excavation in Cum 500.00
Civil (b) foundation trenches (2.0-2.50)
Works: m depth and maximum 10 m
Jetty lead: in very stiff (hard) clayey
Structure soil/ rubbish etc.
44 PART-A. 28 Earth filling in foundation Cum 800.00
Civil (c) trenches and plinth in 150 mm
Works: layer with earth available within
Jetty 90 m of the building site to
Structure achive minimum dry density of
90% with optimum moisture
content (Modified proctor test)
including carrying watering,
leveling, dressing and
compacting to a specified
percentage each layer up to
finished level etc. all complete
and accepted by the Engineer.
45 PART-A. 29 Mass concrete (1:2:4) in Cum 250.00
Civil (a) foundation or in floor with
Works: cement, sand (F.M. 1.2) and
Jetty picked jhama brick chips
Structure including breaking of chips,
screening, mixing, laying,
compacting to required level
and curing for at least 7 days
including the supply of water,
electricity, costs of tools &
plants and other charges etc.
all complete and accepted by
Engineer-in-charge. (Cement:
CEM-II/A-M)
Mass concrete in foundation
(1:2:4) with brick chips and
local sand of F.M. 1.2.
46 PART-A. 29 Mass concrete in floor (1:2:4) Cum 150.00
Civil (b) with brick chips and local sand
Works: of F.M. 1.2.
Jetty
Structure
47 PART-A. 30 Brick works with first class Cum 750.00
Civil bricks with cement sand (F.M.
Works: 1.2) mortar (1:6) in foundation
Jetty and plinth, filling the
Structure joints/interstices fully with
mortar, racking out the joints,
cleaning and soaking the bricks
at least for 24 hours before use
and curing at least for 7 days
etc. all complete including cost
of water, electricity and other
charges and accepted by the
Engineer-in-charge. (Cement:
CEM-II/A-M)
48 PART-A. 31 Brick works with first class Cum 500.00
Civil bricks with cement sand (F.M.
Works: 1.2) mortar (1:4) in exterior
Jetty walls including filling the
Structure interstices with mortar, raking
out joints, cleaning and socking
the bricks at least for 24 hours
before use and washing of
sand, necessary scaffolding,
curing at least for 7 days etc.
all complete including cost of
water, electricity and other
charges (measurement to given
as 250 mm width for one brick
length and 375 mm for one
brick and a half brick length)
accepted by the Engineer-in-
charge. (Cement: CEM-II/A-
M) In ground floor
49 PART-A. 32 Suppying laying admixture ltr 20000.00
Civil (a) accepted by the Engineer-in-
Works: charge.
Jetty Water reducing and plasticizer
Structure admixture :
Plastisol/baralchemical is an
excellent plasticizer and wate
rreducing admixture, which
gives high workability to
produce dense, compact and
honeycomb free concrete
resulting in saving of cement
cost. Reduces W/C ratio by
10-15%, increases workability,
higher cohesion, easier palcing
reduces risks of segregation
and bleeding, better
compaction and finishing,
increases strength and
durability.
50 PART-A. 32 Water proofing admixture: ltr 10000.00
Civil (b) Aquagaurd/Baralchemical is a
Works: liquid polymerized water
Jetty proofing admixture, white
Structure colored semi paste liquid based
on reactive with anticorrosive
properties, chloride free, does
not affect concrete, water
proofing admixture for use with
all al typeof morter and
concrete mixed, particularly
suitable for ready mixed
concrete and all type of
structural concrete.
51 PART-A. 33 Survey cost accepted by the LS 1.00
Civil Engineer-in-charge with all kind
Works: of survey equipment providing
Jetty with all ancillary facilities
Structure suitable to work in marine
environment.
52 PART-A. 34 ''Shifting of earth / rubbish cum 442.42
Civil (which will be treated as the
Works: properties of contractor after
Jetty collection) from site to outside
Structure of the project area by any
means including site
improvement by leveling,
watering and dressing etc all
complete as per direction of
the engineer in charge.

Measurement: Considered by
measuring total compacted
earth /rubbish volume.
Mode of payment: Volume
unit.''
53 PART-A. 35 Fender System no 9.00
Civil (a) Supply, fabrication and
Works: installation of steel fender piles
Jetty including wooden fender and all
Structure auxiliary works as per drawings
and specification procured from
an approved source and
material.
54 PART-A. 35 ''Supply, fabrication and no 9.00
Civil (b) installation of rubber fender
Works: with necessary accessory bolt
Jetty and nuts including all auxiliary
Structure works as per drawings and
specification procured from an
approved source, The
Contractor shall submit product
data sheet, quality test results
from a manufacturer who has
track record of supplying
similar items to five major ports
for at least 10 years. During
approval of the product,
certificate of performance must
be submitted from the user
ports.
Rate shall include all for the
product, accessories,
importation cost including
custom duty, installation by
experienced personnel .
''
55 PART-A. 36 Bollard no 5.00
Civil (a) ''Supply and installation of 5
Works: tonne capacity cast steel
Jetty curved head Tee-Head mooring
Structure bollards conforming to strength
grade 65-35 or ASTM A 27 or
equivalent, with all necessary
accessories, fittings and fixing,
bolts and nuts with necessary
anti-rust coating, all complete
as per Drawing, Specification
and direction of the Engineer.
The Contractor shall submit
product data sheet, quality test
results from a manufacturer
who has track record of
supplying similar items to five
major ports for at least 10
years. During approval of the
product, certificate of
performance must be
submitted from the user ports.
Rate shall include all for the
product, accessories,
importation cost including
custom duty, installation by
experienced personnel.
''
56 PART-A. 36 Supplying,fitting fixing no 120.00
Civil (b) Expansion joint filter
Works: materialsand steel assembly all
Jetty complete as per engineer in
Structure charge.
57 PART-A. 37 Carriage of sand, brick bats, Cum/Km 15752.52
Civil (a) shingles, boulders, c.c block,
Works: RCC Pile, geo-bag, coal, wood
Jetty etc. from different
Structure field/departmental stocks to
work sites by truck/boat/cart
including carriage by head load
upto a distance of 30m at each
point including loading,
unloading and stacking at work
site in measureable stacks
(less than 0.25m neglected) as
per direction of Engineer in
charge.
By cart: Within 1.00 km.
58 PART-A. 37 By cart: Within 2nd km and Cum/Km 7876.26
Civil (b) above.
Works:
Jetty
Structure
59 PART-A. 38 ''Pre-cast spliced pile jointing each 8100.00
Civil by supplying, fitting, fixing
Works: prefabricated square shaped
Jetty two steel caps made up by 6
Structure mm thick ASTM A36 complied
M.S plate, sides formed by
bent in channel shape to have
only two line of joinery on
faces, having min 50 mm dia
hole on its web; capping by min
12 mm thick ASTM A36
complied M.S plate shaping the
edges in 45�, having min 40
mm dia hole at centre to pass
25 M.S bar 433 mm in length;
jointed at channels root by
welding; caps fitted with 2 nos
BDS ISO 6935-2009; B400
DWR complied d20 U-bar
1244mm in length by welding,
equidistant from centre holes of
cap and shall have min 75 mm
clear from pile faces; and
finally, the system to be fitted in
correct alignments on pile head
positions waiting for
concereting; both the pile
heads fitted with the steel caps
to be welded together through
v-notches in field, while one of
the complanion segment of
piles drived in ground and other
one placed over it maintaining
true verticality; all complete as
per direction and stepwise
approval leading to final
approval of Engineer-in-charge.
X-Sec of pre cast pile
segments: 350mm x 350 mm ''
60 PART-A. 39 Supply, fabrication and Kg 10000.00
Civil installation of built-up sections
Works: i.e. columns, beams, rafters,
Jetty bracings, struts etc., (up to
Structure level-4) from steel plates
conforming to ASTM A572,
with a minimum yield strength
of 345 MPa, including the cost
of testing of plates, applicaton
of red/grey-oxide primer etc. all
complete as per drawing,
specification and direction of
Engineer-in-charge.
61 PART-A. 40 Preshipment Inspection of No 1.00
Civil PHC Piles in Overseas country
Works: for Factory Acceptance Test (
Jetty 3 Technical Persons)
Structure
62 PART-B: 1 Supplying, fitting and fixing of each 3.00
Jetty European type glazed combi
Sanitary closet, 725 mm x 360 mm x
and 840 mm size, 42.7 kg of
Plumbing weight, including plastic seat
cover, cistern system,
preparing the base with cement
concrete and with wire mesh or
rods if necessary, in all floors
including making holes
wherever required and mending
good the damages and fitting,
fixing, finishing complete with all
necessary fittings and
connections approved and
accepted by the Engineer-in-
charge. Special Coloured
63 PART-B: 2 Supplying, fitting and fixing of each 2.00
Jetty Bangladesh pattern long pan,
Sanitary made of vitreous China light
and colour 525 mm x 295 mm x 285
Plumbing mm size, 5.7kg of weight and
preparing the base of pan with
cement concrete and with wire
mesh or rods if necessary in all
floors including making holes
wherever required and mending
good the damages and fitting,
fixing, finishing etc. complete
with all necessary fittings and
connections approved and
accepted by the Engineer- in-
charge.
64 PART-B: 3 Supplying, fitting and fixing of each 2.00
Jetty European type glazed porcelain
Sanitary low-down, capacity 10 liter,
and 490 mm x 190 mm x 350 mm in
Plumbing size, approximately 14 kg of
weight, on walls by screws and
F.I. bar clamps, rowel plugs,
making holes wherever
required and mending good the
damages and fitting, fixing and
finishing etc. complete with all
necessary fittings and
connections approved and
accepted by the Engineer- in-
charge.Coloured
65 PART-B: 4 Supplying, glazed vitreous W/H each 4.00
Jetty Wash Basin in/c pedastal
Sanitary approx. size 656 x 510 x 845,
and 26 kg by weight including
Plumbing fitting, fixing the same in
position with heavy type C.I.
Brackets. 30 mm dia PVC
waste water pipe with brass
coupling (not exceeding 750
mm in length). 12mm plastic
lead (connection) pipe with
brass coupling, basin waste
with chain plug including making
holes in walls and floors and
fitting with wooden blocks,
screws and mending good the
damages, finishing etc. all
complete approved and
accepted by the
Engineer.Coloured (Marble
Shaded)
66 PART-B: 5 Supplying, fitting and fixing of Each 4.00
Jetty 450 x 600 mm size and 5 mm
Sanitary thick unframed super quality
and mirror with hard boards at the
Plumbing back with all necessary fitting
including making holes in walls
and mending good the
damages with cement mortar
(1:4) etc. all complete
approved and accepted by the
Engineer. (Made in Japan or
equivalent)
67 PART-B: 6 Supplying, fitting and fixing Each 4.00
Jetty super quality 600 x 125 mm
Sanitary coloured glass (plate) shelf
and having 5 mm thickness with
Plumbing fancy C.P. brackets, screws
and frames including making
holes in walls and mending
good the damages with cement
mortar (1:4) etc. all complete
approved and accepted by the
Engineer.
68 PART-B: 7 Supplying, fitting and fixing of each 3.00
Jetty super quality C.P. towel rail of
Sanitary 600 mm long and 20 mm in dia
and with C.P. holder including
Plumbing making drills in walls and
mending good the damages
with cement mortar (1:4) etc.
all complete approved and
accepted by the Engineer- in-
charge.
69 PART-B: 8 Supplying, fitting and fixing of each 5.00
Jetty special toilet paper holder with
Sanitary cover of size (150 mm x 150
and mm x 126 mm) including
Plumbing making drills in walls and
mending good the damages
with cement mortar (1:4) etc.
all complete approved and
accepted by the Engineer- in-
charge.Coloured (porcelain)
70 PART-B: 9 Supplying, fitting and fixing of each 4.00
Jetty standard size soap tray
Sanitary including making holes in walls
and and mending good the
Plumbing damages with cement mortar
(1:4) etc. all complete
approved and accepted by the
Engineer- in- charge.
71 PART-B: 10 Supplying, fitting and fixing each 8.00
Jetty plastic grating with hinged
Sanitary cover size 150 x 150 mm in
and traps or in drains including
Plumbing making holes in walls/floors and
mending good the damages
with cement mortar (1:4) etc.
all complete approved and
accepted by the Engineer.
72 PART-B: 11 Supplying, fitting and fixing of each 3.00
Jetty Liquid soap dispenser (push-up
Sanitary type) to dispense 16 oz (.47
and liters) of soap, detergent or
Plumbing lotion. Unit shall be fabricated
of tamper resistant, chrome
plated plastic, a translucent
white polyethylene soap
container, and a corrosion
resistant dispensing valve
which can provide no more than
5 lbs (22.2 Newtons) pressure
and unit can be reloaded by
unscrewing base from bracket
collar, inverting unit, and
unscrewing soap container in
which soap will continue to feed
properly until empty with a
continuously visible soap level
etc. all complete approved and
accepted by the Engineer- in-
charge.
73 PART-B: 12 Supplying 100 mm inside dia rm 200.00
Jetty best quality uPVC soil, waste
Sanitary and ventilation pipe having
and specific gravity 1.35-1.45, wall
Plumbing thickness 3.4- 4.0 mm, and
other physical, chemical,
themal, fire resistivity
properties etc. as per BSTI
approved manufacturer
standards or ASTM,
BS/ISO/IS standards fitting
and fixing in position with
sockets, bends, with all
accessories such as round
grating/domed roof grating
bands, sockets etc. approved
and accepted by the Engineer-
in- charge.
74 PART-B: 13 Supplying best quality uPVC rm 50.00
Jetty waste and ventilation pipe
Sanitary having specific gravity 1.35 -
and 1.45, wall thickness 2.5 mm -
Plumbing 3.0 mm, and other physical,
chemical, themal, fire resistivity
properties etc. as per BSTI
approved manufacturer
standards or ASTM,
BS/ISO/IS standards fitting
and fixing in position with
sockets, bends, of uPVC Pipe
with all accessories such as
Round grating /domed roof
grating bands, sockets etc.
approved and accepted by the
Engineer- in- charge.
c) 75 mm dai uPVC pipe
75 PART-B: 14 Supplying different inside dia rm 50.00
Jetty (a) best quality CPVC pressure
Sanitary pipe for water supply having
and specific gravity 1.35 - 1.45, and
Plumbing other physical, chemical,
thermal, fire resistivity
properties etc. as per BSTI
approved manufacturer
standards or ASTM,
BS/ISO/IS standards fitting
and fixing in position with
sockets, bends, with all
accessories such as round
grating/domed roof grating,
bends, sockets etc. approved
and accepted by the Engineer-
in-charge (length: 6000 mm
each).
19 mm dia wall thickness 2.9
mm - 3.4 mm
76 PART-B: 14 25 mm dia wall thickness 3.4 rm 1000.00
Jetty (b) mm - 4.0 mm
Sanitary
and
Plumbing
77 PART-B: 14 37 mm dia wall thickness 3.7 rm 1000.00
Jetty (c) mm - 4.3 mm
Sanitary
and
Plumbing
78 PART-B: 14 75 mm dia wall thickness 3.7 rm 3000.00
Jetty (d) mm - 4.3 mm
Sanitary
and
Plumbing
79 PART-B: 15 Supplying different inside dia each 13.00
Jetty (a) best quality uPVC clean out /
Sanitary trap having specific gravity 1.35
and -1.45 and other physical,
Plumbing chemical, themal, fire resistivity
properties etc. as per BSTI
approved manufacturer
standards or ASTM,
BS/ISO/IS standards, fitting
and fixing in position etc.
complete approved and
accepted by the Engineer- in-
charge.
i) 100 mm dia uPVC ?P? or ?
S? trap
80 PART-B: 15 ii) 100 mm dia uPVC Y or T - each 2.00
Jetty (b) Y Cleanout
Sanitary
and
Plumbing
81 PART-B: 16 Supplying, fitting and fixing of each 6.00
Jetty best quality faucets etc.
Sanitary complete approved and
and accepted by the Engineer- in-
Plumbing charge.
12 mm special quality CP bib
cock
82 PART-B: 17 Supplying, fitting and fixing of each 4.00
Jetty best quality CP pillar cock etc.
Sanitary complete approved and
and accepted by the Engineer- in-
Plumbing charge.12 mm Special heavy
duty CP Piller cock
83 PART-B: 18 Supplying, fitting and fixing of each 12.00
Jetty angle stop cock etc. complete
Sanitary approved and accepted by the
and Engineer- in- charge.12 mm
Plumbing surface special heavy type
angle stop cock
84 PART-B: 19 Groove cutting in brick work rm 50.00
Jetty and R.C.C work, including cost
Sanitary for concealing of G.I. pipe
and work (12 mm and 20 mm dia)
Plumbing in brick wall by cutting groove
in wall, lintel, beam etc. by any
means carefully without
damaging the structure and
filling the grooves with C.C
(4:2:1) after laying of pipe
including cost of scaffolding,
finishing, curing etc. all
complete approved and
accepted by the Engineer- in-
charge.
Groove size 40 mm x 40 mm
(for laying 12 mm to 20 mm dia
pipes)
85 PART-B: 20 Supplying, fitting and fixing of each 1.00
Jetty (a) best quality G.I. gate valve
Sanitary with sealant etc. complete
and approved and accepted by the
Plumbing Engineer- in- charge.
25mm brass gate valve
86 PART-B: 20 37mm brass gate valve each 1.00
Jetty (b)
Sanitary
and
Plumbing
87 PART-B: 20 75 mm brass gate valve each 2.00
Jetty (c)
Sanitary
and
Plumbing
88 PART-B: 21 Supplying, fitting and fixing of rm 3500.00
Jetty 200 mm inside diameter and
Sanitary wall thickness 2.7 mm - 3.4
and mm best quality uPVC rain
Plumbing water down pipe fitting, fixed in
position with head and shoes,
bends, minimum20 mm width
F.I. Bar clamp and nails, and
including all accessories such
as round grating/domed roof
grating, bands, sockets
approved and accepted by the
Engineer- in- charge.
89 PART-B: 22 Supplying and fitting-fixing hand each 3.00
Jetty / push shower for ablution
Sanitary including holder etc. all
and complete approved and
Plumbing accepted by the Engineer- in-
charge.Moving type hand
shower
90 PART-B: 23 Supplying, fitting and fixing of each 3.00
Jetty plastic grating with hinged
Sanitary cover size 150 mm x 150 mm in
and traps or in drains including
Plumbing making holes in walls/floors and
mending good the damages
with cement mortar (1:4) etc.
all complete approved and
accepted by the Engineer- in-
charge.
91 PART-B: 24 Stop cock concealed (heavy) each 1.00
Jetty
Sanitary
and
Plumbing
92 PART-B: 25 Supplying, fitting and fixing of each 2.00
Jetty glazed vitreous standing bowl
Sanitary urinal, fitting, fixing the same in
and position after making holes in
Plumbing walls and floors, providing 32
mm dia plastic waste pipe with
brass coupling up to grading
below, 12 mm dia plastic
connection pipe with brass
coupling, 12 mm dia brass stop
cock including mending good
the damages with cement
mortar (1:4) etc. all complete
approved and accepted by the
Engineer- in- charge.Special
coloured
93 PART-B: 26 Supplying, fitting and each 1.00
Jetty installation of automatic hand
Sanitary drier of high speed, energy
and efficient, rapid drying,
Plumbing automatic sensor, adjustable
speed and sound control,
adjustable heat control, electric
hand dryer; surface mounted or
semi recessed which can
eliminate over 99% of airborne
bacteria and particles as small
as 0.3 microns with the
removable Super Filter System
and it shall be powered by
220v AC supply/ batteries and
shall operate automatically
from IR sensor that shall
activate it when hands are
placed in sensor zone etc. all
complete accepted by the
Engineer- in- charge.
94 PART-C: 1 ''Providing, Fitting & Fixing of Each 150.00
Jetty imported type 7.62 meter long
Electrical (single length) Conical shape
Works galvanized lighting pole, top
dia. 100mm, bottom dia.
190mm, metal thickness
4.5mm with baseplate size
(500x500)mm, thickness
20mmincluding 4 nos. 32mm
dia. anchor bolt, 700mm long
as per drawing & design.
? Material of Pole body,
Lighting arm should be SS400
following JIS G3101 or
equivalent.
? Material grade of Steel plate
(more than 4.5mm thickness) is
SM490YA following JIS
G3106 or equivalent.
? Lighting pole are applied
Longitudinal seam weld, not
welded Horizontal pole body.
? Lighting pole shall be Hot Dip
Zinc Galvanized according to
standard ASTM A123 or
equivalent.''
95 PART-C: 2 ''Providing, Fitting & Fixing of Each 10.00
Jetty imported type 10 meter long
Electrical (single length) Conical shape
Works galvanized lighting pole, top
dia. 100mm, bottom dia.
190mm, metal thickness
4.5mm with baseplate size
(500x500)mm, thickness
20mmincluding 4 nos. 32mm
dia. anchor bolt, 700mm long
as per drawing & design.
? Material of Pole body,
Lighting arm should be SS400
following JIS G3101 or
equivalent.
? Material grade of Steel plate
(more than 4.5mm thickness) is
SM490YA following JIS
G3106 or equivalent.
? Lighting pole are applied
Longitudinal seam weld, not
welded Horizontal pole body.
? Lighting pole shall be Hot Dip
Zinc Galvanized according to
standard ASTM A123 or
equivalent.''
96 PART-C: 3 ''Erection of following tubular Each 150.00
Jetty pole on RCC base via anchor
Electrical bolt system.
Works 7620 mm (25?) long MS/GI /
Spun P.C pole with 457 mm
x457 mm x6.35 mm (1'-6''''x 1'-
6''''x 0?-0.25?) size steel base
plate.''
97 PART-C: 4 ''Supply & fixing of OSRAM each 150.00
Jetty LED Street Light Luminaire
Electrical type SIM ST 120W VS1 or
Works equivalent Brand product Only.
Data:
Efficacy: 140lm/W
CCT: 4000K
CRI (Ra) > 70
SDCM: 5
Beam Angle:
〖151〗^0x〖68〗^0
Power Factor: >0.95
Total Harmonic Distortion ≤
20%
Surge Protection:
Line to Line: 5KV
Ling to Ground: 10KV
Housing: Die-Cast aluminum
Ingress Protection (IP): 66
Compact Resistance (IK): 09
Replaceable LED module and
driver
Safety Approval: Electrical
Protection Class I, CB, CE &
CQC
Operating Temp: -〖30〗^0 C
to +〖55〗^0C''
98 PART-C: 5 ''Supply & fixing of LED flood Nos 4.00
Jetty light fitting of the following
Electrical features and model with all
Works necessary elements such as
driver, chips etc. complete.
Model & sample shall be
approved by the Engineer .
(i) ENERGY + model no -
EPFDL - 17011 / 200 W
or equivalent product of
SUNKO, GLORIA etc.
(ii) Rated life : 50,000 hr
(minimum)
(iii) Luminux flux : 100 + 1m/w
(iv) LED chips : EDISON /
EPISTOR / OSRAM /
PHILIPS / CREE /
BRIDGELUX.
(v) Driver : MEANWELL /
OSRAM / PHILIPS / IEC
standard.
(vi) body: Aluminium body.''
99 PART-C: 6 ''Concealed conduit wiring with meter 7000.00
Jetty the following PVC insulated
Electrical and sheathed stranded cable
Works (NYY) / XLPE insulated and
PVC sheathed stranded cable
(2XY) & PVC insulated Green
/ White colour ECC wire (BYA)
through PVC conduit of
reputed manufacturer complete
with fixing materials other
accessories etc. as required
including mending the damages
good. All electrical contacts
shall be of brass / copper
connected through connector or
soldering (no twisting shall be
allowed) and cables shall be
manufactured and tested
according to relevant IEC /
BDS / BS / VDE standards
The work shall be carried out
as per direction & approval of
the Engineer.
Cables manufactured by govt.
of Bangladesh owned / shared
company ltd. (Eastern cables)
approved by the Engineer.
1C-2x6 sqmm (NYY) with 6
sqmm (BYA) ECC wire
through the PVC pipe of
minimum inner dia 25 mm &
wall thickness 1.5 mm''
IC-2x6 sqmm (NYY) with 6
sqmm (BYA) ECC wire
through the PVC pipe of
minimum inner dia 25 mm &
wall thickness 1.5 mm
100 PART-C: 7 1C-2x16 sqmm (NYY) with 16 Meter 1000.00
Jetty sqmm (BYA) ECC wire
Electrical through PVC pipe of minimum
Works inner dia 40 mm having wall
thickness of 1.9 mm
101 PART-C: 8 (a) Surface conduit wiring with the meter 200.00
Jetty following PVC insulated cable
Electrical (BYA) & PVC insulated Green
Works / White color ECC wire (BYA)
through PVC conduit of
reputed manufacturer complete
with 18 SWG GP sheet pull
box with 3mm thick ebonite
sheet cover, fixing materials,
other accessories etc. including
mending the damages good as
required. All electrical contacts
shall be of brass / copper
connected through connector or
soldering (no twisting shall be
allowed) and cables shall be
manufactured and tested
according to relevant IEC /
BDS / BS / VDE standards.
1C-2x1.5sqmm (BYA) cable
with 1.5sqmm (BYA) ECC wire
through PVC pipe of minimum
inner dia 20 mm having wall
thickness of 1.5 mm
102 PART-C: 8 (b) 1C-2x2.5sqmm (BYA) cable meter 20.00
Jetty with 2.5sqmm (BYA) ECC wire
Electrical through PVC pipe of minimum
Works inner dia 25.4 mm having wall
thickness of 1.5 mm
103 PART-C: 9 (a) ''Providing & fixing 250 volts. Each. 4.00
Jetty 5/6 amps. (minimum)
Electrical concealed type following switch
Works / switch socket manufactured
and tested in accordance with
relevant IEC/
VDE/NEMA/BS/JIS standards
mounted on required size 18
SWG galvanized plain sheet
board of 76.2 mm (3'''') depth.
All electrical contacts shall be
of brass/copper .
Gang Switch of MK/MEM/
Legrand/ Schneider/ABB or
equivalent brand
accepted/approved by the
Engineer''
One gang switch
104 PART-C: 9 (b) Two gang switch Each. 1.00
Jetty
Electrical
Works
105 PART-C: 9 (c) Three gang switch Each. 1.00
Jetty
Electrical
Works
106 PART-C: 9 (d) Four gang switch Each. 8.00
Jetty
Electrical
Works
107 PART-C: 9 (e) One gang switch & one 5 Each. 2.00
Jetty amps. 2-pin socket combined.
Electrical
Works
108 PART-C: 9 (f) 3-pin, 20 amps. Combined DP Each. 2.00
Jetty switch outlet
Electrical
Works
109 PART-C: 10 ''Supply & fixing of LED spot Nos 7.00
Jetty (a) light fitting of the following
Electrical features and model with all
Works necessary elements such as
driver, chips etc. complete.
Model & sample shall be
approved by the Engineer .
''''(i) Square panel (surface
type) ENERGY+ cat. no.-
EPPLLED 2005 or equivalent
product of GLORIA, SUNKO,
ENERGYPAC etc.
(ii) Rated life : 30,000 hr
(minimum)
(iii) Luminux flux : 100 + 1m/w
(iv) LED chips : EDISON /
EPISTOR / OSRAM /
PHILIPS / CREE /
BRIDGELUX.
(v) Driver : MEANWELL /
OSRAM / PHILIPS / IEC
standard.''''''
6 watt
110 PART-C: 10 12 watt Nos 24.00
Jetty (b)
Electrical
Works
111 PART-C: 11 ''Supplying & fixing AC Each 16.00
Jetty capacitor type ceiling fan
Electrical (without regulator) of following
Works specifications and sizes
complete with minimum 305
mm. (1 ft) long down rod,
blades, capacitor canopy, etc.
connecting PVC wire complete
as required .
Rated voltage : 220 volts
Rated frequency : 50 Hz
Rated speed : 300 rpm � 10
%
Service Value : Minimum 2.80
m3/ min/watt
Temperatur Rise : Maximum
70�C
Class of Insulation : Class-E
1422.4 mm. (56'''') Sweep
SEC Diamond or equivalent
brand accepted/approved by
the Engineer.''
112 PART-C: 12 Providing & fixing box type fan Each 16.00
Jetty clamp made of 25.4 mm. x
Electrical 6.35 mm. (1''x �'') MS flat bar
Works with 15.87 mm. (5/8'') dia MS
hook including necessary bolts,
nuts etc. as required as per
sample approved by the
Engineer.
113 PART-C: 13 ''Supply of following oil- Unit 1.00
Jetty immersed, natural air cooled,
Electrical 3-phase, 50-Hz, 11KV/0.415
Works KV & 0.24 KV indoor/outdoor
type distribution transformer of
Dyn11 vector group complete
with two windings of high
conductivity copper having
basic impulse insulation level 75
KV , dielectric strength 28 KV
(for 1 min), HT & LV porcelain
bushings, manual 5 position
standard tap changer,
conservator, thermometer, oil
inlet & outlet valves, oil level
indicator, dehydrating breather,
lifting lugs, earthing terminals,
wheel, data plate etc. including
painting, suitable for operation
at 40�C ambient temperature
with maximum temperature rise
60�C, locally manufactured
and tested in Bangladesh as
per NEMA / VDE / IEC / BS
standards.
(a) Capacity : 400 KVA
(b) No load loss : 700 watts
(maximum)
(c ) Full load loss : 4500 watts
(maximum)
(d) Percentage impedance :
4~4.6 %
(e) Transformer oil dielectric
breakdown voltage >50KV
(f) Meggar insulation resistance
>60,000 megaohms
Note: Manufacturer have to
provide test report of delivered
transformer rating & other
criteria as defiened above from
reputed testing authority like
BUET/KUET/CUET/RUET or
other govt recognized/owned
lab.
Manufactured by the valid ISO-
9001 certified company having
test certificate (within 5 years)
for the required or higher
capacity of transformer
according to relevant IEC
standards from BUET / CUET
/ DUET / KUET / RUET.''
114 PART-C: 14 ''Supply of 415 V, 3-phase, 50 Unit 1.00
Jetty Hz, indoor type low tension
Electrical switch-gear of following
Works specification complete with
voltmeter (0-500V) & ammeter
of adequate rating both with
selector switch, indicating
lamps for ON-OFF and
arrangement for following
components (components such
as TPMCCBs shall be
manufactured according to
relevant NEMA / VDE / IEC /
JIS / BS standards and shall
have type test certificate
(within 5 years) according to
relevant IEC Standard)
assembled locally in 14 SWG
sheet steel metal clad, dust &
vermin proof, free standing,
floor mounting, epoxy resin
powder coat painted cabinet as
per relevant IEC standards and
as per accepted / approved by
the Engineer. (Rate is
excluding the supply of
TPMCCB)
Assembled by the valid ISO-
9001 certified company having
test certificate (within at least
five years) according to
relevant IEC standards from
BUET / CUET / DUET / KUET
/ RUET.
For 400 KVA transformer :
Incoming:1X630A TP MCCB
Outgoing: 1x500A TPMCCB
1x400A TPMCCB
1x80A TPMCCB
800A Bus-bar , TPNE.''
115 PART-C: 15 ''Supply of following 415 volt, 3 Unit 1.00
Jetty phase, 50 Hz power factor
Electrical improvement panel complete
Works with TP bus bars and earth
block, micro processor
controlled auto power factor
correction relay with digital PF
reading display, capacitor
bank, contactor, fuse, ON
indicators for every stage of
capacitor bank (except directly
connected one) etc. shall be
manufactured & tested as per
NEMA / VDE / IEC / JIS / BS
standards assembled locally in
16 SWG sheet steel clad dust
& vermin proof, free standing,
floor mounting, epoxy resin
powder coat painted cabinet as
per relevant IEC standards and
as per accepted / approved by
the Engineer.
Assembled by the valid ISO-
9001 certified company having
test certificate (within five
years) according to relevant
IEC standards from BUET /
CUET / DUET / KUET /
RUET.
For 400 KVA transformer ( PFI
capacity - 240 KVAR )
3 Nos.- 415V, 500A hard
drawn electrolytic copper bus
bar.
1 No.- 415V, 12.5 KVAR, 50
Hz TP power capacitor bank
with built in / separate
discharge coil for connection
directly with line through fuse. ''
''1 No.- 415V, 10 KVAR, 50 Hz
TP power capacitor bank with
built in / separate discharge
resistor.
2 Nos.- 415V, 12.5 KVAR, 50
Hz TP power capacitor bank
with built in / separate
discharge resistor.
4 Nos.- 415V, 25 KVAR, 50 Hz
TP power capacitor bank with
built in / separate discharge
resistor.
2 Nos.- 415V, 50 KVAR, 50 Hz
TP power capacitor bank with
built in / separate discharge
resistor.
1 No.- 415V, 20 A 50 Hz auto
TP magnetic contactor with
AC3 duty.
2 Nos.- 415V, 16 A 50 Hz auto
TP magnetic contactor with
AC3 duty.
4 Nos.- 415V, 40 A 50 Hz auto
TP magnetic contactor with
AC3 duty.
2 Nos.- 415V, 80 A 50 Hz auto
TP magnetic contactor with
AC3 duty.
9 Nos.- 415V, 25 A HRC fuse
with base.
3 Nos.- 415V, 20 A HRC fuse
with base.
12 Nos.- 415V, 50 A HRC fuse
with base.
6 Nos.- 415V, 100 A HRC fuse
with base.''
116 PART-C: 16 ''Supply of 11 KV, 3-phase, 50 Unit 1.00
Jetty Hz, indoor type, high tension
Electrical switchgear complete with Load
Works Break Switch (LBS), 800 A
hard-drawn electrolytic copper
bus-bars, 1 No. 0-15 KV range
voltmeter & 1 no. ammeter of
adequate ranges both with
selector switch, 1 no. of panel
heater with auto thermostat
control switch, manual ON &
OFF push button switch and
indicators including following
components (components such
as LBS, HRC fuse, CT, PT
shall be manufactured & tested
as per NEMA / VDE / IEC /
JIS / BS Standards )
assembled locally in 14 SWG
sheet steel clad, dust & vermin
proof, free standing, floor
mounting, epoxy resin powder
coat painted cabinet as per
relevant IEC standards and as
per accepted / approved by the
Engineer.
CT Ratio For 400 KVA
transformer 15/5
LBS (load break switch):
1 Set of 11 KV, 630 A (25KA),
50 Hz, triple pole, manually
operated off load isolator
interlocked with earth switch.
1 Set of 11 KV, 630A (25KA),
50 Hz, spring charged, stored
energy mechanism triple pole
load break switch (LBS)
complete with 3 no's of 11 KV
HRC fuse of suitable Amps.
(25KA) with spring operated
striker pin plunger for automatic
tripping activated by any of the
three fuses blow-up.2 Nos. of
11 KV, double pole, cast resin
insulated, dry type Potential
transformer (P.T.) having ratio
11/0.11, 50VA, class 0.5 for
metering.
3 Nos. of 11 KV, cast resin
insulated, dry type, single core
Current transformer (C.T.)
having adequate current ratio
(compatible with the
transformer capacity) burden
10-15VA of class 0.5 M5 for
metering.
1 No of 415V, 6A ( 10 KA), 50
Hz. TPMCB for PT secondary
protection.
Assembled by the valid ISO-
9001 certified company having
test certificate(within at least 5
years) according to relevant
IEC standards from BUET /
CUET / DUET / KUET /
RUET.''
117 PART-C: 17 ''Supply of HT metering unit for Unit 1.00
Jetty 11kv sub-station with TP hard
Electrical drawn electrolytic copper bus
Works bar earth link bars manufacture
16 SWG power coat painted
louver sheet steel metal
enclosed free standing floor
mounting dust and vermin proof
completely factory assembled
& suitable for indoor use
including all standard IP54
accessories manufactured &
type tested in accordance with
NEMA / IEC / JIS / BDS
standards (Country of origin :
USA / Japan / EU countries or
relevant electricity supply
authority and as per
approved/accepted by the
Engineer.
1 no. 3-phase 4 wire
single/double tariff solid state
programmable KWH meter
with LCD display, MDI on kw
integration period 30 minutes.
3 nos. cast resin PT
Ratio: 11000 : root 3/110v :
root 3
Burden: 50VA, class : 0.5 for
metering
1 no. TPMCCB for PT
secondary protection
3 nos. cast resin CT??/ 5A
(adedequte rating to be
inserted )
15 VA class 0.5 M5 for
metering with selector switch
3 nos. indicating light phase
indicator RYB
1 set cable terminal block with
cover
1 no. panel heater.
''
118 PART-C: 18 ''Supplying of 220/415 V , 3 nos 10.00
Jetty (a) phase , 50 Hz following
Electrical capacity , Control circuit
Works breaker feeder unit as per
following specification with
thermal overcurrent and
instantaneous electromagnetic
short circuit release
manufactured and tested as
per NEMA/IEC/VDE/BS/JIS
standards for sub-station L.T
panel & Sub-Distribution box at
vaious floor.
Rated operating voltage: 220-
690 V,
Rated insulation voltage: 690
V,
Rated impulse withstand
voltage: 6 KV
Utilization Category: A or B
TPMCCB of the following
brand:
ABB/Dorman Smith/ Schnieder
/AEG/ SIEMENS/ ABB/
LEGRAND or equivalent
accepted/approved by E/C.''
10A SP MCB
119 PART-C: 18 16 A SP MCB nos 3.00
Jetty (b)
Electrical
Works
120 PART-C: 18 20A SPMCB nos 3.00
Jetty (c)
Electrical
Works
121 PART-C: 18 40A TPMCCB nos 1.00
Jetty (d)
Electrical
Works
122 PART-C: 18 400A TPMCCB nos 1.00
Jetty (e)
Electrical
Works
123 PART-C: 18 (f) 500A TPMCCB nos 1.00
Jetty
Electrical
Works
124 PART-C: 19 ''Providing & laying of the meter 60.00
Jetty (a) following PVC insulated &
Electrical sheathed cable (NYY) /
Works (XLPE) insulated & PVC
sheathed cable (2XY) with
PVC insulated Green / White
colour ECC wire (BYA)
connecting at both ends,
through PVC pipe &
accessories in the following
manner. All electrical contacts
shall be of brass / copper
connected through connector or
soldering (no twisting shall be
allowed) and cables shall be
manufactured and tested
according to relevant IEC /
BDS / BS / VDE standards .
The work shall be carried out
as per direction & approval of
the Engineer.
In kutcha ground by cutting
45.70 cm width x 91.40 cm
depth trench with necessary
brick or tile protection and
mending the damages good by
refilling trench with proper
compaction;
In pucca floor through PVC
pipe by cutting trench of
necessary size and mending
the damages good by brick
soling, 75 mm (1:2:4) CC work
with neat cement finishing etc.
Cables manufactured by govt.
of Bangladesh owned / shared
company ltd. (Eastern cables)
approved by the Engineer. ''
1C-4x500 sqmm (NYY) with
240 sqmm (BYA) ECC wire
through PVC pipe of minimum
inner dia 125 mm having wall
thickness of 3 mm
In pucca floor
125 PART-C: 19 3c x 120 sqmm XLPE cable meter 300.00
Jetty (b) In kutcha ground
Electrical
Works
126 PART-C: 19 In pucca floor through 100mm meter 600.00
Jetty (c) PVC pipe having wall thickness
Electrical of 3mm.
Works
127 PART-C: 19 In pucca ground / pucca road meter 200.00
Jetty (d) through 100 mm PVC pipe
Electrical having wall thickness of 3 mm.
Works
128 PART-C: 20 ''Making following cable trench meter 10.00
Jetty in pucca floor having 76.2 mm
Electrical (3'''') thick CC (4:2:1) base on
Works one layer of flat brick soling
over 76.2 mm (3'''') thick sand
bedding at the bottom, 127 mm
(5'''') thick brick work (4:1) at
the sides complete with 12.7
mm (1/2'''') plaster and neat
cement finishing duly covered
with 4.8 mm (3/16'''') thick MS
sheet having necessary lifting
lugs :
trench dimension: W (width) ?
610 mm x D (depth) ? 864 mm

''
129 PART-C: 21 ''Supply and fixing of loop cable meter 30.00
Jetty of this following sizes From
Electrical transformer to LT switchgear
Works (without ECC & conduit )
Cable manufacturer(s) must
have valid test certificate from
internationally accrediated
laboratory (like CRRI, KEMA
etc.) accepted / approved by
the Engineer.
1C - 4 x 500 sqmm ( NYY )

''
130 PART-C: 22 ''Supply and fixing of loop cable meter 10.00
Jetty of this following sizes From LT
Electrical switchgear to PFI plant
Works (without neutral, ECC and
conduit)
Cable manufacturer(s) must
have valid test certificate from
internationally accrediated
laboratory (like CRRI, KEMA
etc.) accepted / approved by
the Engineer.
1C - 3 x 120 sqmm ( NYY )''
131 PART-C: 23 ''Supply of 400KVA, 400 & 230 Unit 1.00
Jetty V, 3-phase, 4-wire, 50 Hz. air /
Electrical water cooled, floor mounted,
Works indoor type following
continuous capacity (prime
power) electric generating set
suitable for tropicalized country
complete with four stroke,1500
rpm, diesel engine with all
standard accessories viz.
12/24 volt DC battery & auto
battery charger with ammeter,
radiator assembly, oil & fuel
pump, auto speed governor, air
cleaner, fuel & oil tank, level &
oil pressure gauge, RPM &
hour meter, start & stop switch,
exhaust silencer (to keep
standard emission level),
mounting spring and vibration
isolator (to keep very minimum
vibration in the room), mounting
steel base frame etc. including
safety & protection device viz.
auto shut off with indicators for
overload, over & under voltage,
high temperature, low oil
pressure, over speed, low fuel
level etc. coupled with brush
less, self excited alternator
having control panel with auto
voltage regulator, voltmeter &
ammeter with selector switch,
frequency meter.
TPMCCB of required rating for
overload & instantaneous short
circuit release , manual change
over switch, indicator for ON-
OFF-TRIP etc. including
maintenance tools, 3 sets of
detailed technical catalogues &
maintenance manual and
manufactured, assembled and
tested in accordance with
NEMA / IEC / VDE / JIS
standards (subject to satisfy
standard test and approved by
PWD). WITH ATS AND
SOUND ATTENUATED
ACOUSTICALLY TREATED
CANOPY(maximum sound
level : 75 dBA at 7m distance
in the generator room). The
generating set shall be
assembled & tested in USA /
JAPAN / EU countries. The
major components like engine
shall be of Perkins / Deutz /
Cummins / Mitsubishi / Volvo /
Kohler / Yanmar brand and
alternator shall be of Stamford
/ Meccalte / Leroy Somer /
Kohler brand. The engine,
alternator, ATS, canopy shall
also be manufactured and
tested as per relevant
standards in USA / JAPAN /
EU countries & accepted /
approved by the Engineer. ''
132 PART-C: 24 ''Installation, testing & each 1.00
Jetty commissioning of following
Electrical electric generator on prepared
Works CC pad with the help of
necessary T & P, skilled labour,
technician, Engineer including 2
hrs. / 5 day trial run operation
by skilled operator with supply
of necessary fuel & lubricant as
per manufacturers instruction
manual and in accordance with
relevant IEC / NEMA / VDE /
JIS standards so that vibration
transfer rate to foundation shall
be almost zero.
400 KVA ? 500 KVA
manual/auto/auto with
soundproof acoustically treated
canopy generating set. ''
133 PART-C: 25 ''Providing and fixing of conceal Nos 1.00
Jetty type sub-distribution board with
Electrical mounting bridge of 18 SWG
Works sheet steel having inner shutter
through which knobs of the
MCCB/MCBS are projected
out but covered with hinged
type outside shutter with built in
both push type and English lock
arrangement including lock and
key duly painted with powder
coat paint complete in
conformity with B.N.B.C
including busbars and following
TP MCCB/SPMCBS having
thermal over current and
instantaneous electromagnetic
short circuit release, cutting
and mending good all the
damages as per direction of
the Engineer in charge.
SDB size : 2.5'X2'X5''
4 nos 12'' X 1.5'' X 4 mm and 1
no 12'' X 1.5'' X 4 mm. for
earthing mounted on insulator
at both ends indivisually . Equal
size of hole on bar at 0.5''
individually. 2'''-3'' gap between
each bar with protective glass
cover in front of Busbar.

Incoming:1X40ATP MCCB
Outgoing: SPMCB Channel
with 8X10A/16A/20A SP
MCB,150A Bus-bar , TPNE.''
134 PART-D: 1 ''Driving pre-cast pile of 350 Rm 11388.60
Retaining mm x 350 mm cross section
Wall made with shoe/ without shoe
by Hydraulic static pile driver of
approx. 500 tonne (metric ton)
capacity; arranged with
necessary cranes, power
source, maintaining driving log
and record of pressure exerted
on piles driven in to desired RL
or capacity level ; complete in
all respect including handling of
piles, dressing & leveling of
site, way making, surveying,
layout setting etc ended with
the submission of pile driving
report in three copies duly
signed by professional engineer
and approved by the Engineer-
in-charge.
Full length of the pile shall be
considered for measurement
and payment.''
135 PART-D: 2 Casting of pre-cast pile with Cum 1395.10
Retaining reinforced cement concrete
Wall having minimum cement content
relates to mix ratio 1:1.25:2.5,
minimum f'cr = 35 Mpa, and
satisfying specified
compressive strength f?c = 30
Mpa at 28 days on standard
cylinders as per standard
practice of Code
ACI/BNBC/ASTM & cement
conforming to BDS EN-197-1-
CEM-I (52.5 N) / ASTM-C 150
Type ? I, best quality coarse
sand (F.M.2.2), 20 mm down
well graded crushed stone
chips conforming to ASTM C-
33, mixing in standard mixture
machine and fed by standard
measuring boxes, including all
related works like screening
through proper sieves, cleaning
and washing, centering and
shuttering with M.S sheet, M.S
angle, F.I bar, nuts and bolts,
champering edges if so,
preparation of casting beds,
laying polythene there in,
placing reinforcement cages in
position, casting, compacting
by vibrators and tapered rods
as where necessary, curing for
28 days etc., cost of water,
electricity, all materials and
other charges, providing fitting
and fixing pile shoe in position,
tools, plants & equipments,
mobilization, demobilization,
labour, conducting laboratory
test of materials and concrete
etc. all complete as per design,
drawing and accepted by the
Engineer-in-charge. (Rate is
excluding the cost of
reinforcement and its
fabrication, binding, welding
and placing)
350 mm x 350 mm size pre-
cast pile (1:1.25:2.5) with
stone chips
136 PART-D: 3 Labour for breaking head of Cum 34.45
Retaining hardened cast in situ bored
Wall pile/pre-cast pile up to a
required length by any means
but without damaging the rest
and removing the dismantled
materials such as concrete to a
safe distance including scraps
and cleaning concrete from
steel/M.S. rods, straightening
and bending of pile bars,
preparation and making
platform where necessary,
carrying, all sorts of handling,
stacking the same properly
after clearing, levelling and
dressing the situ and clearing
the bed etc. complete in all
respect and accepted by the
Engineer-in-charge.
(Measurement will be given for
the actual pile head volume to
be broken)
137 PART-D: 4 (a) Earth work in excavation in all sqm 1575.00
Retaining kinds of soil for foundation
Wall trenches including. layout,
providing center lines, local
bench-mark pillars, leveling,
ramming and preparing the
base, fixing bamboo spikes and
marking layout with chalk
powder, providing necessary
tools and plants, protecting and
maintaining the trench dry etc.,
stacking, cleaning the
excavated earth at a safe
distance out of the area
enclosed by the layout etc. all
complete and accepted by the
Engineer, subject to submit
method statement of carrying
out excavation work to the
Engineer for approval.
However, Engineer's approval
shall not relieve the contractor
of his responsibilities and
obligations under the contract.
Layout and marking for
earthwork in excavation in
foundation accepted by the
Engineer. [Plinth area of the
structure shall be considered
for measurement]
138 PART-D: 4 (b) i) Earthwork in excavation in Cum 2300.00
Retaining foundation trenches up to 1.5 m
Wall depth and maximum 10 m lead:
in very stiff (hard) clayey soil/
rubbish etc.
139 PART-D: 4 (c) Earth filling in foundation Cum 2362.50
Retaining trenches and plinth in 150 mm
Wall layer with earth available within
90 m of the building site to
achive minimum dry density of
90% with optimum moisture
content (Modified proctor test)
including carrying watering,
leveling, dressing and
compacting to a specified
percentage each layer up to
finished level etc. all complete
and accepted by the Engineer.
140 PART-D: 5 (a) Reinforced cement concrete Cum 1417.50
Retaining works with minimum cement
Wall content relates to mix ratio
1:1.5:3 having minimum f'cr =
30 MPa, satisfying a specified
compressive strength f?c = 25
MPa at 28 days on standard
cylinders as per standard
practice of Code
ACI/BNBC/ASTM, Cement
conforming to BDS EN-197-1-
CEM-I, 52.5N (52.5 MPa) /
ASTM-C 150 Type ? I, with
approved high range admixture
(complying specific type under
ASTM -C494) best quality
Sylhet sand or coarse sand of
equivalent F.M. 2.2 and 20 mm
down well graded stone chips
conforming to ASTM C-33,
making and placing shutter in
position and maintaining true to
plumb, making shutter water-
tight properly, placing
reinforcement in position;
mixing with standard mixer
machine with hopper, fed by
standard measuring boxes or
mixing in batching plant, casting
in forms, compacting by
vibrator machine and curing at
least for 28 days, removing
centering-shuttering after
specified time approved;
including cost of water,
electricity, testing charges of
materials and concrete
cylinders as required, cost of
all materials and other charges
etc. all complete, approved and
accepted by the Engineer-in-
charge. (Rate is excluding the
cost of reinforcement and its
fabrication, placing, binding etc.
and the cost of shuttering &
centering)
Individual & combined footing,
pile cap, raft/mat, floor slab
and foundation beam up to
plinth level
141 PART-D: 5 (b) Pedestals, column, column Cum 1204.49
Retaining capital, lift wall and RCC wall
Wall
142 PART-D: 6 ''Picon Shutter / Scaffolding : sqm 16510.82
Retaining Reinforced cement concrete
Wall shutter works using Picon set,
12mm Garjan play, build & cast
in specified module of different
sizes. Fixed in position using 08
(eight) 25~38mm GI /MS Pipe
/Box (Sampl as per
Engineering Office). Making
and placing shutter in position
and maintaining true to plumb,
making shutter water-tight
properly, placing reinforcement
in position, removing centering-
shuttering after specified time
approved; Shutter /props /
scafflding having designed &
calculated by contractor and
vatted by the engineer in
charge with all necessary
materials including but not
limited to welding,
straightening, finishing with zero
leak.

Measurement : Actual shutter


area will be calculated.
Mode of payment: Paymnet
will be in shutter area unit.
Individual and combined
footing''
143 PART-D: 7 ''Centering and shuttering, sqm 7612.30
Retaining including strutting, propping
Wall with special arrangement as
per site need etc. (The
formwork must be rigid enough
both in and out of plane, to
make the concrete surface true
to the designed shape and size
by using necessary MS sheets
of minimum 16 BWG, angles
of minimum size 50 mm x 50
mm x 6 mm, flat bars,,
structural steel joist, and
structural tubes of approved
grade and size etc.- the
contractor shall be responsible
to submit shop drawings of the
shuttering for approval of the
Engineer-in-charge) and
removal of form after hardening
of the concrete for:

Pedestal, column, column


capital, lift wall and wall ''
144 PART-D: 8 Supplying, fabrication and fixing kg 677497.32
Retaining to detail as per design : ribbed
Wall or deformed bar reinforcement
for Reinforced cement
concrete, produced and
marked in accordance with
BDS ISO 6935 - 2: 2006 (or
standard subsequentley
released from BSTI) including
straightening and cleaning rust,
if any, bending and binding in
position with supply of G.I.
wires, conducting necessary
laboratory tests etc. (excluding
splices or laps) complete in all
respect and accepted by the
Engineer-in-charge
(Measurement shall be
recorded only on standard
mass per unit length of bars,
while dia of bars exceeds its
standard)
Grade 400 (RB 400 /RB
400W: complying BDS ISO
6935-2:2006) ribbed or
deformed bar produced and
marked according to
Bangladesh standard, with
minimum yield strength, fy
(ReH)= 400 MPa but fy not
exceeding 450 MPa and
whatever is the yield strength
within allowable limit as per
BNBC/ ACI 318, the ratio of
ultimate tensile strength fu to
yield strength fy, shall be at
least 1.25 and minimum
elongation after fracture and
minimum total elongation at
maximum force is 16% and 8%
respectively : up to ground
floor.
Grand
Total :

Schedule of Day works

Table
.
Name :
Unit Total Total
Item
Item Description Measurement Nominal Unit Price in Figures Price in Price in Price in
Group Code (if
no. of Item Unit Quantity (BDT) Words Figures Words
any)
(BDT) (BDT) (BDT)
01 Day 01 NIL Nil 1
works
Grand
Total :

Unconditional Discount Form

Table
Unconditional Discount
Name :
Discount in Percentage (%)[In figure] Discount in Percentage (%) [In word]