0% found this document useful (0 votes)
52 views2 pages

Dip Switch Setting SW03

This document provides instructions for setting the address codes for communication devices using dip switches. It lists the binary codes to set for switches SW03_1 through SW03_8 to assign address numbers 0 through 127 to the communication center controller and indoor unit addresses.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
52 views2 pages

Dip Switch Setting SW03

This document provides instructions for setting the address codes for communication devices using dip switches. It lists the binary codes to set for switches SW03_1 through SW03_8 to assign address numbers 0 through 127 to the communication center controller and indoor unit addresses.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Initial setting

Operate according to the following setting as necessary after refrigerant piping construction and
electrical wiring construction are finished.
Code setting for the postal address of the valve box:
SW03 is used for MS devices address setting, 1 is ON, 0 is OFF
Manner of set 0 Set the address with automatism (default)
SW03_1
address 1 Set the address with dip switch
Communication Center controller
[2] [3] [4] [5] [6] [7] [8]
address address
0 0 0 0 0 0 0 0#(default) 0#(default)
0 0 0 0 0 0 1 1# 1#
0 0 0 0 0 1 0 2# 2#
0 0 0 0 0 1 1 3# 3#
0 0 0 0 1 0 0 4# 4#
0 0 0 0 1 0 1 5# 5#
0 0 0 0 1 1 0 6# 6#
0 0 0 0 1 1 1 7# 7#
0 0 0 1 0 0 0 8# 8#
0 0 0 1 0 0 1 9# 9#
0 0 0 1 0 1 0 10# 10#
0 0 0 1 0 1 1 11# 11#
0 0 0 1 1 0 0 12# 12#
0 0 0 1 1 0 1 13# 13#
0 0 0 1 1 1 0 14# 14#
The 0 0 0 1 1 1 1 15# 15#
SW03_2 communication 0 0 1 0 0 0 0 16# 16#
~ addressFirst 0 0 1 0 0 0 1 17# 17#
SW03_8 indoor unit 0 0 1 0 0 1 0 18# 18#
address 0 0 1 0 0 1 1 19# 19#
0 0 1 0 1 0 0 20# 20#
0 0 1 0 1 0 1 21# 21#
0 0 1 0 1 1 0 22# 22#
0 0 1 0 1 1 1 23# 23#
0 0 1 1 0 0 0 24# 24#
0 0 1 1 0 0 1 25# 25#
0 0 1 1 0 1 0 26# 26#
0 0 1 1 0 1 1 27# 27#
0 0 1 1 1 0 0 28# 28#
0 0 1 1 1 0 1 29# 29#
0 0 1 1 1 1 0 30# 30#
0 0 1 1 1 1 1 31# 31#
0 1 0 0 0 0 0 32# 32#
0 1 0 0 0 0 1 33# 33#
0 1 0 0 0 1 0 34# 34#
0 1 0 0 0 1 1 35# 35#
0 1 0 0 1 0 0 36# 36#

20
Initial setting
Communication Center controller
[2] [3] [4] [5] [6] [7] [8]
address address
0 1 0 0 1 0 1 37# 37#
0 1 0 0 1 1 0 38# 38#
0 1 0 0 1 1 1 39# 39#
0 1 0 1 0 0 0 40# 40#
0 1 0 1 0 0 1 41# 41#
0 1 0 1 0 1 0 42# 42#
0 1 0 1 0 1 1 43# 43#
0 1 0 1 1 0 0 44# 44#
0 1 0 1 1 0 1 45# 45#
0 1 0 1 1 1 0 46# 46#
The 0 1 0 1 1 1 1 47# 47#
communication 0 1 1 0 0 0 0 48# 48#
SW03_3
addressFirst 0 1 1 0 0 0 1 49# 49#
~SW03_8
indoor unit 0 1 1 0 0 1 0 50# 50#
address 0 1 1 0 0 1 1 51# 51#
0 1 1 0 1 0 0 52# 52#
0 1 1 0 1 0 1 53# 53#
0 1 1 0 1 1 0 54# 54#
0 1 1 0 1 1 1 55# 55#
0 1 1 1 0 0 0 56# 56#
0 1 1 1 0 0 1 57# 57#
0 1 1 1 0 1 0 58# 58#
0 1 1 1 0 1 1 59# 59#
0 1 1 1 1 0 0 60# 60#
0 1 1 1 1 0 1 61# 61#
0 1 1 1 1 1 0 62# 62#
0 1 1 1 1 1 1 63# 63#
1 0 0 0 0 0 0 0# 64#
1 0 0 0 0 0 1 1# 65#
1 0 0 0 0 1 0 2# 66#
… … … … … … … …… ……
1 1 1 1 1 1 0 62# 126#
1 1 1 1 1 1 1 63# 127#