0% found this document useful (0 votes)
30 views

EwallvarR2-C 4m

1. The document summarizes the design of a gravity retaining wall with a key depth of 0.3m. 2. Stability calculations are performed to check for sliding and overturning, accounting for passive pressure from the soil and concrete key. 3. The factor of safety against sliding is calculated to be 1.785, which meets the minimum requirement of 2.0 since passive pressure from the soil above point A is included.

Uploaded by

James Tan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views

EwallvarR2-C 4m

1. The document summarizes the design of a gravity retaining wall with a key depth of 0.3m. 2. Stability calculations are performed to check for sliding and overturning, accounting for passive pressure from the soil and concrete key. 3. The factor of safety against sliding is calculated to be 1.785, which meets the minimum requirement of 2.0 since passive pressure from the soil above point A is included.

Uploaded by

James Tan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 5

GRAVITY RETAINING WALL DESIGN (Moment about toe) SLIDING CHECK 1. Passive pressure from rc key always included.

PKNS Wall C 4m ASSUMPTIONS 2. When key depth>0.3m, assume sliding surface within soil, ie, δ = Ø (but limit to 30 degrees)
Include passive pressure from soil above Point A (y/n)? y (if 'y', min. FOS:2.0 ; else 1.5)

q M@toe 0.075 stresses perpendicular to wall at heel of rubble wall


0.15 m M@A 2.857
0 m 0.30 m Sliding 1.785 min 2.0 0 kPa
Neg.Pr ok 0 kPa
β BrgCap. ok
act all 56 100
a=
3.50
H1 = m γ z Kacosβ
5.25
m P1
H=
GWL 5.25 21.00 kPa 0 kPa
m P5 qhKacosβ
h=
33.33

5.00 m la1 + +
w=
:1

1.7 1.75 P2 γsub z Kacosβ γw z la5


1.00 m m
: 1!
#DIV/0

0.9 m P3 P4
250 mm la2 la3 la4
toe heel
0.50 m 0.45 m B 21.00 + 5.367 17.17 kPa 0 kPa
= 26.37 kPa
k=
2.35 m 0.45 m 0.00 m 0.50 m soil hydrostatic surcharge
A 3.70 m

3.70 m

Surcharge, q = 0 kPa qh: 0 kPa Using Rankine Theory, // to slope, Overturning Moment @ toe of rubble wall

[ β−√ ( cos2 β− cos 2 φ' )


]
Allow. bearing capacity: 100 kPa Ka = cos
×cos β
Angle of β : 0 deg. or 0 rad
cos β+ √ ( cos2 β−cos2 φ' ) Item P (kN) la (m) Moment (kNm)

Unit weight of wall : 24 kN/m3 = 1.000 - 0.500 x 1.000 1 0.5 x 21.00 x 3.50 = 36.75 2.92 107.19
Soil adhesion angle, delta, δ : 30 deg. or 0.52 rad 1.000 + 0.500 2 21.00 x 1.75 = 36.75 0.88 32.16
Soil friction angle, phi Ø' : 30 deg. or 0.52 rad = 0.3333 3 ( 26.37 - 21.00 ) /2 x 1.75 = 4.70 0.58 2.74
Soil unit weight, γ : 18 kN/m 3
4 0.5 x 17.17 x 1.75 = 15.02 0.58 8.76
Saturated unit weight: 19 kN/m3 pa,// = γzKa ; Ka,h = Ka cosβ = 0.333 5 0.00 x 5.25 = 0.00 2.63 0.00
Submergd unit weight: 9.2 kN/m3 pa,h = γzKa,h ; pa,v = γzKasinβ Σ = 93.2 Σ = 150.85
GRAVITY RETAINING WALL DESIGN (Moment about toe)
PKNS Wall C 4m

0.105 0.05 Surcharge, q : 0 kPa Soil unit weight, γ : 18 kN/m3


m m q
0.15 m Hor. Area., qh : 0 kPa Saturated unit weight: 19 kN/m3
0 m 0.30 m
0.00 Angle of β : : 0 deg. Submergd unit weight: 9.2 kN/m3
β b m or 0 rad
Total O.T. Moment @ A: 150.8 kNm
a
Unit weight of wall : 24 kN/m3
3.500 Total R.T. Moment @ A: 11.3 kNm
c H1 = m Soil friction angle, phi Ø' : 30 deg.
e 5.00 or 0.52 rad F.O.S (Overturning): 0.075
m

GWL
h= 2 Section V (kN) lm R.T. Mom (kNm)
5.00 m d

w= 1 ½ ( 0.00 x 5.00 x 24 )= 0.00 0.000 0.00


3 1.500 2 0.30 x 5.00 x 24 = 36.00 0.150 5.40
1.00 m 0.90 m m 3 ½ ( 0.15 x 5.00 x 24 )= 9.0 0.350 3.15

1
toe heel a ½ ( 0.11 x 3.50 x 18 )= 3.31 0.370 1.22
0.45 m
0.50 m b ½ ( 0.15 x 0.00 x 18 )= 0.00 0.400 0.00

k= c 0.05 x 3.50 x 18 = 2.8 0.428 1.21


2.35 m 0.45 m 0.00 m 0.50 m
A 3.70 m d ½ ( 0.05 x 1.50 x 19 )= 0.64 0.435 0.28

lm1 e ( P1 + P2 + P3 + P5 ) / cosβ x sinβ


lm2 78.2 / 1 x 0 = 0.00 0.450 0.00
lm3
lma q 0.00 x 0.15 / cosβ = 0.00 0.375 0.00
lmb

lmc Σ = 51.8 Σ = 11.26


lmd
lme
GRAVITY RETAINING WALL DESIGN (Moment about A)
PKNS Wall C 4m soil hydrostatic surcharge
1.05 m stresses perpendicular to wall at face B
q
0.15 m 0 kPa 0
0 m 0.30 m

β
kPa
a=
3.50
H1 = m γ z Kacosβ
5.5 P1
m
H=
GWL 5.50 21.00 kPa 0 kPa
m P5 qhKacosβ
h=
5.00 m la1 + +
w=
33.3

1.7 2.00 P2 γsub z Kacosβ γw z la5


:1

1.00 m m
#DIV/0:! 1

0.90 m
250 mm la2
toe heel la3 P3 P4
0.50 m 0.45 m B la4
0 kPa
k= 21.00 + 6.133 = 27.13 kPa 19.62 kPa
2.35 m 0.45 m 0.00 m 0.50 m
A 3.70 m 27.13 + 1.533 = 28.67 kPa 19.62 + 4.905 = 24.53 kPa 0.00 kPa

[ √ ( cos β− cos φ )
]
2 2 '
cos β−
× cos β
Using √ ( cos β− cos φ )
2 2 '
cos β+
Surcharge, q = 0.0 kPa qh: 0 kPa Rankine Theory, // to slope, Overturning Moment @ Point A

Allow. bearing capacity: 100 kPa Ka =


Angle of β : 0 deg. or 0 rad Item P (kN) la (m) Moment (kNm)

Unit weight of wall : 24 kN/m3 = 1.000 - 0.500 x 1.000 1 0.5 x 21.00 x 3.50 = 36.75 3.17 116.38
1.000 + 0.500 2 21.00 x 2.00 = 42.00 1.00 42.00
Soil friction angle, phi Ø' : 30 deg. or 0.52 rad = 0.3333 3 ( 27.13 - 21.00 ) /2 x 2.00 = 6.13 0.67 4.09
Soil unit weight, γ : 18 kN/m 3
4 0.5 x 19.62 x 2.00 = 19.62 0.67 13.08
Saturated unit weight: 19 kN/m 3 pa,// = γzKa ; Ka,h = Ka cosβ = 0.333 5 0.00 x 5.50 = 0.00 2.75 0.00
Submergd unit weight: 9.2 kN/m3 pa,h = γzKa,h ; pa,v = γzKasinβ Σ = 104.5 Σ = 175.54
Additional Sliding Force below Point A
Padd={( 28.67 + 27.13 )/2 + ( 24.53 + 19.62 )/2 + ( 0.00 )}x 0.50
= { 27.90 + 22.07 + 0.00 }x 0.50 = 24.99 kN
GRAVITY RETAINING WALL DESIGN (Moment about A)
PKNS Wall C 4m 0.105 0.05 Hor. Area surchg, qh : 0.00 kPa Saturated unit weight: 19 kN/m3
m m q
0.15 m 0.000 m Angle of β : 0 deg.OR 0 rad Submergd unit weight: 9.2 kN/m3
0 m 0.30 m f
0.00 m Unit weight of wall : 24 kN/m3 Total O.T. Moment @ A: 175.5 kNm
β b

Soil unit weight, γ : 18 kN/m3 Total R.T. Moment @ A: 501.5 kNm


a

Ø' : 30 deg.OR 0.52 rad F.O.S (Overturning): 2.857


c 3.500 m

m g H1 Section V (kN) lm R.T. Mom (kNm)


GWL 5.00 1 ½ ( 0.00 x 5.00 x 24.0 )= 0.00 2.350 0.000
e 2 0.30 x 5.00 x 24.0 = 36.00 2.500 90.000
h= 2 3 ½ ( 0.15 x 5.00 x 24.0 )= 9.00 2.700 24.300
5.00 m d

a ½ ( 0.11 x 3.50 x 18.0 )= 3.31 2.720 8.996


w=
3 1.500 b ½ ( 0.15 x 0.00 x 18.0 )= 0.00 2.750 0.000
1.00 m m
c 0.05 x 3.50 x 18.0 = 2.84 2.778 7.874
1
toe
0.45 m 0.9 m d ½ ( 0.05 x 1.50 x 19.0 )= 0.64 2.785 1.786
0.50 m i
e 0.90 x 3.50 x 18.0
ii k= + 0.90 x 1.50 x 19.0 = 82.4 3.250 267.638
2.35 m 0.45 m 0.00 m 0.50 m
A 3.70 m f ½ ( 0.90 x 0.00 x 18.0 )= 0.00 3.400 0.000

lm1 g (P1 + P2 + P3 + P5) / cosβ x sinβ


lm2 84.9 / 1 x 0 = 0.00 3.70 0.000
lm3
lma q 0.00 x 1.05 / cosβ = 0.00 3.175 0.000
lmb
lmc i 3.70 x 0.50 x 24.0 = 44.40 1.850 82.140
lmd
lme ii 0.45 x 0.50 x 24.0 = 5.40 3.475 18.765
lmf

lmi Σ = 183.93 Σ 501.50


lmii
GRAVITY RETAINING WALL DESIGN
PKNS Wall C 4m δ = 30 deg. or 0.52 rd
Total O.T. Moment @ A: 175.5 kNm Ø' = 30 deg. or 0.52 rd
Total R.T. Moment @ A: 501.5 kNm Use Ø' = 30 deg. or 0.52 rd
CL Total vert. Force Σ V: 183.9 kN ENTER Ø' req. for Kp if difft. : 30 deg. or 0.52 rd
Allow. bearing capacity: 100 kPa Kp = 1 + sin Ø' = 1 + 0.500
1.00 m toe heel 1 - sin Ø' 1 - 0.500
R = 3.00
0.50 m Σ V
Location of Resultant, R (EV=Rv)
m k= Sliding Check
2.35 m 0.45 m 0.00 m 0.50 x = Σ MA = Σ Mrt - Σ Mot Driving force, Pah = P1+P2+P3+P4+P5+Padd = 129.49 kN
0.078

A m Σ V Σ V
Weight of soil displ.= 3.25 x 0.50 x 18.00 = 29.25 kN
=

= 501.5 - 175.5 = 1.772 m by key, Ws Use Ws = 29.3 kN


e

x = 1.772 m B/2 183.9


Resisting force, Fr = ( ΣV+Ws) tan δ { μ=tanδ = 0.5774 }
B = 3.70 m e = 1.850 - 1.772 = 0.078 m (friction) = 213.2 x tan 30.0 = 123.08 kN
Key>0.3m =>use δ =Ø'

BASE PRESSURE CALCULATIONS


Check Middle Third Rule

B/6 = 0.617 m
Resisting force, Fpu = ½ Kp γ Hp2
e < B/6 ie. ok (passive ) = ½ x 3.00 x 18 x 2.00 2

43.43 (soil above Point A) = 108.00 kN


kPa R LIES WITHIN MIDDLE THIRD OF BASE
56.0 => O.K.
kPa
F.O.S. = Fr + Fpu
Maximum & Minimum Base Pressures are given by Pah

p = Σ V 1 ± 6e = 183.9 1 ± 6 x 0.078 = 49.7 1 ± 0.126 = 123.1 + 108 = 1.785 < 2.000


B B 3.70 3.70 129.49
ok = 55.99 kPa AND 43.43 kPa => change!!

Bearing Capacity Check ASSUMPTION

Since Pmax is less than the allowable soil bearing capacity of 100 kPa, 1. Passive pressure from rc key always included.
the base is adequate=> O.K. ok 2. When key depth>0.3m, assume sliding surface within soil, ie, δ = Ø (but limit to 30 degrees)