100% found this document useful (1 vote)
169 views1 page

Solar Home System Design

This document summarizes the design of a solar home system to power loads totaling 37.5 watts per day. It specifies: 1) A 12V, 55Ah lead-acid battery to provide 3 days of autonomy based on a daily load of 90Wh. 2) A 40Wp solar panel to charge the battery, with 20% additional capacity to account for losses. 3) A charge controller rated for the panel's 3.17A short circuit current. 4) A 52W inverter sized to handle the maximum 3.47A DC load at 12V.

Uploaded by

Raly Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
169 views1 page

Solar Home System Design

This document summarizes the design of a solar home system to power loads totaling 37.5 watts per day. It specifies: 1) A 12V, 55Ah lead-acid battery to provide 3 days of autonomy based on a daily load of 90Wh. 2) A 40Wp solar panel to charge the battery, with 20% additional capacity to account for losses. 3) A charge controller rated for the panel's 3.17A short circuit current. 4) A 52W inverter sized to handle the maximum 3.47A DC load at 12V.

Uploaded by

Raly Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Md.

Tahmid Farhan Himel

Solar Home System Design


Load(230V) Watt Usage Unit Total Watt Total Wh/day
Florescent 7.5 3 3 22.5 67.5
Lamp
TV 14’’ 15 1.5 1 15 22.5
Total 37.5 90

Battery Specification: 12V, 55Ah, DOD 60%, Efficiency 80%


System Loss 10%, System Efficiency 95%, Days of Autonomy 3.
Battery Sizing:
90
DC Wh/day = = 105.26 Available Battery Rating :12V, 24V
0.9∗0.95
105.26
Ah load = =8.77 (Ah: 15,20,30,40,45,55,60, 80, 85, 100)
12
8.77∗3
Required Ah = = 54.18 Ah Cable Selection: Cable Type DC
0.6∗0.8
54.18
No of Battery = 55
=1 2 Rm, 4 Rm, 6 Rm, 10 Rm

PV Module Specification: 40 Wp, Isc=2.54 A, Im=2.31, 12 V


PV Module Output = 2.31*12*4.2= 116.42 (Insolation = 4.2 KWh/m2)
105.26
No. of Module= = 1 (System Loss 20%) Available PV Module (Wp): 40,55,75,
116.42∗0.8

80, 125, 165, 180, 325, 375.


Charge Controller Selection
Charge Controller Current= 1.25*Short Circuit Current of PV Module=1.25*2.54=3.17A
37.5
Maximum DC Load Current= =3.47 A (Inverter Efficiency 90% )
12∗0.9
Inverter Selection
37.5∗1.25
= = 52 Watt. (Inverter Efficiency 90%)