100% found this document useful (1 vote)
127 views

Solar Home System Design

This document summarizes the design of a solar home system to power loads totaling 37.5 watts per day. It specifies: 1) A 12V, 55Ah lead-acid battery to provide 3 days of autonomy based on a daily load of 90Wh. 2) A 40Wp solar panel to charge the battery, with 20% additional capacity to account for losses. 3) A charge controller rated for the panel's 3.17A short circuit current. 4) A 52W inverter sized to handle the maximum 3.47A DC load at 12V.

Uploaded by

Raly Mohamed
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
127 views

Solar Home System Design

This document summarizes the design of a solar home system to power loads totaling 37.5 watts per day. It specifies: 1) A 12V, 55Ah lead-acid battery to provide 3 days of autonomy based on a daily load of 90Wh. 2) A 40Wp solar panel to charge the battery, with 20% additional capacity to account for losses. 3) A charge controller rated for the panel's 3.17A short circuit current. 4) A 52W inverter sized to handle the maximum 3.47A DC load at 12V.

Uploaded by

Raly Mohamed
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Md.

Tahmid Farhan Himel

Solar Home System Design


Load(230V) Watt Usage Unit Total Watt Total Wh/day
Florescent 7.5 3 3 22.5 67.5
Lamp
TV 14’’ 15 1.5 1 15 22.5
Total 37.5 90

Battery Specification: 12V, 55Ah, DOD 60%, Efficiency 80%


System Loss 10%, System Efficiency 95%, Days of Autonomy 3.
Battery Sizing:
90
DC Wh/day = = 105.26 Available Battery Rating :12V, 24V
0.9∗0.95
105.26
Ah load = =8.77 (Ah: 15,20,30,40,45,55,60, 80, 85, 100)
12
8.77∗3
Required Ah = = 54.18 Ah Cable Selection: Cable Type DC
0.6∗0.8
54.18
No of Battery = 55
=1 2 Rm, 4 Rm, 6 Rm, 10 Rm

PV Module Specification: 40 Wp, Isc=2.54 A, Im=2.31, 12 V


PV Module Output = 2.31*12*4.2= 116.42 (Insolation = 4.2 KWh/m2)
105.26
No. of Module= = 1 (System Loss 20%) Available PV Module (Wp): 40,55,75,
116.42∗0.8

80, 125, 165, 180, 325, 375.


Charge Controller Selection
Charge Controller Current= 1.25*Short Circuit Current of PV Module=1.25*2.54=3.17A
37.5
Maximum DC Load Current= =3.47 A (Inverter Efficiency 90% )
12∗0.9
Inverter Selection
37.5∗1.25
= = 52 Watt. (Inverter Efficiency 90%)