Prima TII Productspecifications
Prima TII Productspecifications
FCR PRIMA T2
Product Specifications
1st Edition
Nov. 2012
FCR® FCR PRIMA T2 Product Specifications
Contents
1. Overview ....................................................................................................................................... 1
2. Features ........................................................................................................................................ 1
4. Specifications ................................................................................................................................ 2
4.1 Available IP cassette types and sizes ............................................................................................ 2
4.2 Available IP types and sizes........................................................................................................... 2
4.3 Processing Capacity....................................................................................................................... 2
4.4 Image Reading ............................................................................................................................... 4
4.5 Connection ..................................................................................................................................... 4
4.6 Limitation of X-ray exposure........................................................................................................... 4
7. Environmental Conditions.............................................................................................................. 5
3. System Components
3.1 Standard Components FCR PRIMA T2 Image Reader Unit* (Model: CR-IR 392)
* It is hereafter called “RU”.
3.2 Options (1) AC cord
(2) Table Fix Kit
※Required when using for mobile.
However, when using the option " Stand Wagon (including
Table Fix Kit as an accessory)", this kit is not needed.
(3) Stand WagonAdditional Stand for LCD (Attach to (2))
(4) Cassette rack (Attach to (3))
(5) Cassette rack for LC (Attach to (3))
(6) Arm for LCD Monitor (Attach to (3))
(7) Stand wall fix kit (Attach to (3))
(8) CPU floor mount kit (Attach to (3)
(9) Support Bar for LC cassette (Attach to (2))
(10) Dummy cassette for mobile.
※Required when using for mobile.
Z30N0949 11.2012
1
FCR® FCR PRIMA T2 Product Specifications
4. Specifications
4.1 Available IP cassette • Type CC (Standard type) / Type LC*
types and sizes 14"×17" ,14"×14" ,10"×12", 8"×10",
35×43cm, 35×35cm, 24×30cm, 18×24cm,15×30cm
Z30N0949 11.2012
2
FCR® FCR PRIMA T2 Product Specifications
•A 100Base-TX cable is used for connection between the RU and the Console
Z30N0949 11.2012
3
FCR® FCR PRIMA T2 Product Specifications
4.6 Limitation of X-ray • When reading an unexposed IP again that has been used once, there is
exposure a possibility that a residual image may emerge. The erasure must be
performed on the IP, especially in cases where the x-ray exposure is
small.
• It is necessary to re-erase an IP again after reading when it has been
exposed to a large x-ray dose (defined below). In addition, when exposed
to a large dose continuously, the IP may suffer from x-ray damage.
<X-ray shot with large amount of dose>
Over 400mR (103,200 nC/kg) with W target X-ray tube
Z30N0949 11.2012
4
FCR® FCR PRIMA T2 Product Specifications
5. Principles of Operation
5.1 X-ray Exposure The IP cassette containing an erased IP is set in an X-ray exposure unit,
and exposed to X-ray.
5.2 Exposure Condition The patient’s demographic information is entered, and the exposure
Input menu is selected on the Console.
5.3 Image Reading - Film The cassette containing the exposed IP is inserted into the cassette inlet
Output of the RU.
(1) The IP is taken out of the cassette automatically and scanned with the
laser beam at the image reading section. The luminescence from the
IP is collected, converted to electric signals, and then sent to the
image-processing.
(2) The read digital data is processed to make the best image for
diagnosis according to the previously selected exposure menu, and
sent to the Console. The image will then be displayed on the monitor.
The digital data is also used to print the image on film.
(3) The IP whose image signals have been read is then subjected to
erasure. After image is erased at the erasure section, the IP is
returned to the cassette. And then the cassette is returned to the
cassette inlet. This cassette is ready for the next exposure.
7. Environmental Conditions (1) Conditions for Vibration (Random vibration condition for Vehicle)
Vertical direction (Total Energy:Less than 0.3grms)
5~ 20Hz Less than 0.002 ~ 0.002 PSD
20~ 30Hz Less than 0.002 ~ 0.0001 PSD
30~500Hz Less than 0.0001 ~ 0.0001 PSD
Z30N0949 11.2012
5
FCR® FCR PRIMA T2 Product Specifications
Equipment Noise
Operating state : 55dB or less*
(Excluding single sound)
Standby state : 45dB or less*
* Measurement values based on office regulation (Frontal sound
pressure level. Comply with ISO1996-1 and ISO1996-2)
RH
%
90
80
70
60
50
40 Humidity Level
Approximation
Curve
30
20
15
10
15 35
10 20 30 40 °C
Z30N0949 11.2012
6
FCR® FCR PRIMA T2 Product Specifications
Dimensions and weight are approximate and are subject to change without prior to
notice. (Values in the table above do not include those of protrusions.)
Z30N0949 11.2012
7
FCR® FCR PRIMA T2 Product Specifications
100 100
Main unit
Front
700
Rear
200 200
Main unit
Front
700
9.2 Space Required for At least a 700mm space should be secured either in front or rear, or
Maintenance right or left by moving the equipment accordingly.
The maintenance can be done without removing from a desk.
Z30N0949 11.2012
8
FCR® FCR PRIMA T2 Product Specifications