VOC Report Everroll EPDM
VOC Report Everroll EPDM
Am Hilgenacker 24
57319 Bad Berleburg
Deutschland
Test objective: Emission analysis according to AgBB and the DIBt principles for the
health-related evaluation of building products in interiors,
NIK Values List 2018
Name of test sample/item by client: REGUPOL everroll ultimate (thickness 12 mm, colour: red)
Sample/batch by client: 1270 rot
EOTA File No.: 20-19-0010-05.02
EAD Number: 190010-00-0502
Sampled by: Helmut Miss, REGUPOL BSW GmbH
Date of sampling: 16.06.2021
Location of sampling: AWT-Hilgenacker
Date of production: 08.06.2021
Date of arrival of sample: 23.06.2021
Storage of the sample until testing under defined climatic conditions in original packaging
(place / type of packaging):
Test period: 23.06.2021 - 24.08.2021
Date of report: 15.09.2021
Number of pages of report: 23
Test objective fulfilled:
Note: The test results in the report refer exclusively to the test sample submitted by the
manufacturer. The report is not permitted to be used in product and company
advertising. The report may be published in full as technical documentation on the
Internet with the written consent of eco-INSTITUT Germany GmbH. eco-INSTITUT
Germany GmbH has recommended that the manufacturer repeats the test after 3 years
at the latest. More information at www.eco-institut.de/en/advertising
Page 2 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Content
Sample View ............................................................................................................................................................................................. 3
Additional information.............................................................................................................................................................................. 4
Statement of conformity with DIBt emission principles ......................................................................................................................... 5
_________________________________
‡ subcontracted, # outside accreditation
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 3 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Sample View
56488-A001
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 4 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Additional information
Herstellerangaben Prüfstellenangaben
Parameter
Manufacturer's data Testing laboratory´s data
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 5 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
This evaluation is based on the "Requirements for structural systems with regard to health protection" (i.e. „Anforderungen
an bauliche Anlagen bezüglich des Gesundheitsschutzes“, ABG, as of May 2019) from the Model Administrative Regulation for
Technical Building Regulations MVV TB, edition 2019/1 and the requirements of the AgBB-scheme 2018 (Committee for
Health-related Evaluation of Building Products).
The assessment is subject to the confirmation by the “German Institute of Structural Engineering (Deutsches Institut für
Bautechnik DIBt)”.
This test report does not replace a general technical approval by DIBt.
Requirement hold
Test parameter Result Requirement
[yes/no]
Emission analysis
Sum VOC (C6-C16) including SVOC with LCI 1) 0.061 mg/m³ ≤ 10 mg/m³ yes
Sum carcinogenic substances (EU cat. 1A and 1B) < 0.001 mg/m³ ≤ 0.01 mg/m³ yes
Sum VOC (C6-C16) including SVOC with LCI 1) 0.012 mg/m³ ≤ 1 mg/m³ yes
Sum SVOC without LCI (C16-C22) 1) < 0.005 mg/m³ ≤ 0.1 mg/m³ yes
Sum VOC without LCI < 0.005 mg/m³ ≤ 0.1 mg/m³ yes
Sum carcinogenic substances (EU cat. 1A and 1B) < 0.001 mg/m³ ≤ 0.001 mg/m³ yes
1) for Sum VOC (C6-C16) and Sum SVOC (C16-C22) only substances ≥ 5 µg/m³ are considered
1 If a measurement result that slightly exceeds the specification is assessed as “not fulfilled”, this is based on the agreement of the “shared risk of
measurement uncertainty (shared risk approach)”. According to this, the probability that the statement is correct is ≥ 50%. Similarly, a result slightly
below the specification value also only has a probability of ≥ 50 % of being compliant. I.e., the risk of making a false negative statement regarding the
fulfilment of the specification is just as high as the risk of making a false positive statement (more information at https://www.eco-
institut.de/en/2019/07/measurement_uncertainty/).
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 6 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Summary statement of conformity with DIBt / ABG emissions principles / AgBB 2018
The sample with the internal sample no. 56488-A001, article description according to customer: REGUPOL everroll ultimate
(thickness 12 mm, colour: red), meets the "Requirements for structural systems with regard to health protection" (ABG, as of May
2019) and the requirements of the AgBB-scheme 2018.
Cologne, 15.09.2021
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 7 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Laboratory report
1 Emission analysis
Test method
Date: 23.07.2021
Sample preparation: not applicable ..
Analytics
Aldehydes and Ketones DIN ISO 16000-3:2013-01
Limit of quantification: 2 µg/m³
Volatile Organic Compounds DIN ISO 16000-6:2012-11
Limit of quantification: 1 µg/m³ (1,4-Cyclohexanedimethanol, Diethylene glycol,
1,4-Butanediol: 5 µg/m³)
Note for analysis: not specified
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 8 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Test objective:
Volatile Organic Compounds (VOC), test chamber, air sampling 3 days after test chamber loading
Test result:
Internal sample number: 56488-A001
Toluene-
No. Substance CAS No. RT Concentration+ CMR LCI R-value
equivalent
Substances Substances Classifi- AgBB 2018
≥ 1 µg/m³ ≥ 5 µg/m³
cation++
1 Aromatic hydrocarbons
3 Terpenes
7 Aldehydes
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 9 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Toluene-
No. Substance CAS No. RT Concentration+ CMR LCI R-value
equivalent
Substances Substances Classifi- AgBB 2018
≥ 1 µg/m³ ≥ 5 µg/m³
cation++
10 Esters
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 10 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Concentration
SERa
Carcinogenic, mutagenic and reproductive toxic components* after 3 days
[µg/(m²・h)]
[µg/m³]
CMR 1: VOC (incl. VVOC and SVOC) with the following categorisations:
Regulation (EC) No. 1272/2008: Category Carc. 1A and 1B, Muta. 1A and 1B, Repr. 1A and
1B;
TRGS 905: K1A, K1B, M1A, M1B, R1A, R1B; <1 < 1.25
IARC: Group 1 and 2A;
DFG (MAK list): Categories III1, III2
(Sum)
Concentration
SERa
TVOC, Total volatile organic compounds after 3 days
[µg/(m²・h)]
[µg/m³]
Concentration
SERa
TSVOC, Total semi volatile organic compounds after 3 days
[µg/(m²・h)]
[µg/m³]
Sum of SVOC without LCI according to AgBB 2018 / DIBt <5 < 6.25
Sum of SVOC with LCI according to AgBB 2018 / DIBt <5 < 6.25
Concentration
SERa
TVVOC, Total very volatile organic compounds after 3 days
[µg/(m²・h)]
[µg/m³]
Sum of VVOC according to AgBB 2018 / DIBt and Belgian regulation 5 6.3
*Excluding formaldehyde and acetaldehyde (Carc. 1B) due to an assumed "practical threshold" under which a significant carcinogenic risk is no longer to be
expected (see Federal Institute for Risk Assessment (2006): Toxicological evaluation of formaldehyde and Federal Environment Agency (2016): Reference
value for formaldehyde in indoor air and protocol of the 11th meeting of 'Ausschusses für Innenraumrichtwerte' (AIR), 11/2020). In the case of a
toxicological emission assessment, a single-substance analysis of the concentrations is necessary.
In the opinion of the committee for Indoor Air Guide Values (Ausschuss für Innenraumrichtwerte) of the Federal Environment Agency, the concentration of
0.1 mg formaldehyde/m3 indoor air, based on a measurement period of half an hour, should not be exceeded, also for a short time
(Bundesgesundheitsblatt 2016 · 59: 1040-1044 DOI 10.1007 / s00103 -016-2389-5 © Springer-Verlag Berlin Heidelberg 2016).
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 11 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Concentration
SERa
Other sums of VOC after 3 days
[µg/(m²・h)]
[µg/m³]
VOC without LCI according to AgBB/DIBt and Belgian regulation (Sum) <5 < 6.25
CMR 2: VOC (incl. VVOC and SVOC) with the following categorisations:
Regulation (EC) No. 1272/2008: Category Carc. 2, Muta. 2, Repr. 2;
TRGS 905: K3, M3, R3;
9 11
IARC: Group 2B;
DFG (MAK list): Category III3
(Sum)
Note:
Due to different requirements in the respective guidelines, the calculation of TVOC, TVVOC, TSVOC and
R-value may result in different values.
Short-chain carbonyl compounds (C1-C5) are quantified via HPLC acc. to DIN ISO 16000-3:2013-01. Therefore, no toluene equivalents are given for VVOC.
These substances are taken into concern by means of their substance specific calibration via the sum of VVOC acc. to DIN EN 16516:2020-10. For VOC
however, the substance specific calibration takes place via HPLC whereas the TVOC is calculated using the toluene equivalent determined via Tenax acc. to
DIN EN 16516:2020-10.
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 12 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Test objective:
Volatile Organic Compounds (VOC), test chamber, air sampling 28 days after test chamber loading
Test result:
Internal sample number: 56488-A001
Toluene-
No. Substance CAS No. RT Concentration+ CMR LCI R-value
equivalent
Substances Substances Classifi- AgBB 2018
≥ 1 µg/m³ ≥ 5 µg/m³
cation++
7 Aldehydes
8 Ketones
9 Acids
10 Esters
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 13 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Concentration
SERa
Carcinogenic, mutagenic and reproductive toxic components* after 28 days
[µg/(m²・h)]
[µg/m³]
CMR 1: VOC (incl. VVOC and SVOC) with the following categorisations:
Regulation (EC) No. 1272/2008: Category Carc. 1A and 1B, Muta. 1A and 1B, Repr. 1A and
1B;
TRGS 905: K1A, K1B, M1A, M1B, R1A, R1B; <1 < 1.25
IARC: Group 1 and 2A;
DFG (MAK list): Categories III1, III2
(Sum)
Concentration
SERa
TVOC, Total volatile organic compounds after 28 days
[µg/(m²・h)]
[µg/m³]
Concentration after 28
SERa
TSVOC, Total semi volatile organic compounds days
[µg/(m²・h)]
[µg/m³]
Sum of SVOC without LCI according to AgBB 2018 / DIBt <5 < 6.25
Sum of SVOC with LCI according to AgBB 2018 / DIBt <5 < 6.25
Concentration
SERa
TVVOC, Total very volatile organic compounds after 28 days
[µg/(m²・h)]
[µg/m³]
Sum of VVOC according to AgBB 2018 / DIBt and Belgian regulation <5 < 6.25
*Excluding formaldehyde and acetaldehyde (Carc. 1B) due to an assumed "practical threshold" under which a significant carcinogenic risk is no longer to be
expected (see Federal Institute for Risk Assessment (2006): Toxicological evaluation of formaldehyde and Federal Environment Agency (2016): Reference
value for formaldehyde in indoor air and protocol of the 11th meeting of 'Ausschusses für Innenraumrichtwerte' (AIR), 11/2020). In the case of a
toxicological emission assessment, a single-substance analysis of the concentrations is necessary.
In the opinion of the committee for Indoor Air Guide Values (Ausschuss für Innenraumrichtwerte) of the Federal Environment Agency, the concentration of
0.1 mg formaldehyde/m3 indoor air, based on a measurement period of half an hour, should not be exceeded, also for a short time
(Bundesgesundheitsblatt 2016 · 59: 1040-1044 DOI 10.1007 / s00103 -016-2389-5 © Springer-Verlag Berlin Heidelberg 2016).
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 14 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Concentration
SERa
Other sums of VOC after 28 days
[µg/(m²・h)]
[µg/m³]
VOC without LCI according to AgBB/DIBt and Belgian regulation (Sum) <5 < 6.25
CMR 2: VOC (incl. VVOC and SVOC) with the following categorisations:
Regulation (EC) No. 1272/2008: Category Carc. 2, Muta. 2, Repr. 2;
TRGS 905: K3, M3, R3;
<1 < 1.25
IARC: Group 2B;
DFG (MAK list): Category III3
(Sum)
Note:
Due to different requirements in the respective guidelines, the calculation of TVOC, TVVOC, TSVOC and
R-value may result in different values.
Short-chain carbonyl compounds (C1-C5) are quantified via HPLC acc. to DIN ISO 16000-3:2013-01. Therefore, no toluene equivalents are given for VVOC.
These substances are taken into concern by means of their substance specific calibration via the sum of VVOC acc. to DIN EN 16516:2020-10. For VOC
however, the substance specific calibration takes place via HPLC whereas the TVOC is calculated using the toluene equivalent determined via Tenax acc. to
DIN EN 16516:2020-10.
Cologne, 15.09.2021
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 15 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Appendix
Sampling sheet
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 16 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Chromatograms
I Chromatogram after 3 days
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 17 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 18 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 19 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 20 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Definition of terms
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 21 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
R value The quotient of the concentration and the LCI value is generated for
every substance which is detected in the test chamber air.
The sum of the calculated quotients results in the R value.
R value according to eco-INSTITUT-Label R value for all identified substances ≥ 1 µg/m3 with LCI, established
by the AgBB in 2018
R value according to AgBB 2018/DIBt R value for all identified substances ≥ 5 µg/m3 with LCI, established
by the AgBB in 2018
R value according to Belgian regulation R value for all identified substances ≥ 5 µg/m3 with LCI, established
by the Belgian regulation
R value according to EU-LCI R value for all identified substances ≥ 5 µg/m3 with EU-LCI value,
established by the European Commission
RT (retention time) Time for a particular analyte to pass through the system
(from the column inlet to the detector)
CAS No. International unique numerical identifier for a chemical substance
(Chemical Abstracts Service)
Toluene equivalent Concentration, calculated as toluene equivalent
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 22 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Test method
Measurement of the volatile organic compounds takes place in the test chamber in conditions similar to those applying in
practice. Standardized test conditions are defined for the test chamber regarding loading, air exchange, relative humidity,
temperature and incoming air, based on the type of test specimen and the required guideline. These conditions and the
underlying standards are to be found in the section on test methods in the laboratory report.
Air samples are taken from the test chamber at defined points in time during the continuously running test. To this end,
approximately 5 L of air are collected from the test chamber with an air flow rate of 100 mL/min for Tenax and approx. 100 L
with an air flow rate of 0.8 L/min for DNPH (dinitrophenylhydrazine).
After thermal desorption, the substances adsorbed on Tenax are analysed using gas chromatographic separation and mass
spectrometric determination. The gas chromatographic separation is performed with a slightly polar capillary column of 60 m
in length.
The substances derivatized with DNPH for the determination of formaldehyde and other short-chain carbonyl compounds (C1 -
C6) are analysed using high-performance liquid chromatography.
Over 200 compounds, including volatile organic compounds (C6 - C16), semi-volatile organic compounds (C16 - C22) and –
insofar as possible with this method – also very volatile organic compounds (less than C6) are determined and quantified
individually from 1µg/m³.
All other substances – insofar as is possible – are identified through comparison with a library of spectra. The quantification of
these substances and non-identified substances is performed through a comparison of their signal area with the signa of the
standard d8 toluene. The identification and quantification of substances is carried out, as far as technically feasible, from a
concentration (evaluation limit) of 5 µg/m3 test chamber air.
Quality assurance
The eco-INSTITUT Germany GmbH is granted flexible scope of accreditation pursuant to DIN EN ISO/IEC 17025:2018-03. The
accreditation covers the analytical determination of all volatile organic compounds, including the test chamber method.
In each analysis the analytical system is checked using an external standard based on the specifications in standard DIN EN
16516:2020-10. The stability of the analytical systems is documented based on the test standard using control charts.
Laboratory performance is assessed at least once a year in inter-laboratory comparisons by comparing the results with those
obtained by other laboratories for identical samples.
A blank is run prior to introducing the test specimen into the test chamber to check for the possible presence of volatile organic
compounds.
The expanded measurement uncertainty U for the analytical determination of all volatile organic compounds, including the test
chamber method, is estimated to 41.7 %. The calculation is based on DIN ISO 11352:2013-03 (Nordtest).
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.
Page 23 of 23
Test Report N° 56488-001-ABG-L dated 15.09.2021
Emission measurements are accomplished in test chambers under defined physical conditions (temperature, relative humidity,
room loading, air change rate etc.).
Test chamber measurement results are directly comparable only if the investigations were accomplished under the same basic
conditions.
If the differences of the physical conditions refer only to the change of air rate and/or the loading, the "SER" or "specific
emission rate" can be used for comparability of the measurement results. The SER indicates how many volatile organic
compounds (VOC) are released by the sample for each material unit and hour (h).
The SER can be calculated using the formula below for each proven individual component of the VOC from the data in the test
report.
SER thus represents a product specific rate, which describes the mass of the volatile organic compound, which is emitted by
the product per time unit at a certain time after beginning of the examination.
SER = q·c
q specific air flow rate (quotient from change of air rate and loading)
c concentration of the measured substance(s)
The result can be indicated in milligrams (mg) in place of micro grams (µg), whereby 1 mg = 1000 µg.
Remark: It is not permitted to publish extracts of this report and the comments on the first page of this report apply.