DM150 Quick Reference
DM150 Quick Reference
DataMan 150
Reference Manual
08/25/2016
Version 5.6.3
Legal Notices
Legal Notices
The software described in this document is furnished under license, and may be used or copied only in accordance with
the terms of such license and with the inclusion of the copyright notice shown on this page. Neither the software, this
document, nor any copies thereof may be provided to, or otherwise made available to, anyone other than the licensee.
Title to, and ownership of, this software remains with Cognex Corporation or its licensor. Cognex Corporation assumes
no responsibility for the use or reliability of its software on equipment that is not supplied by Cognex Corporation.
Cognex Corporation makes no warranties, either express or implied, regarding the described software, its
merchantability, non-infringement or its fitness for any particular purpose.
The information in this document is subject to change without notice and should not be construed as a commitment by
Cognex Corporation. Cognex Corporation is not responsible for any errors that may be present in either this document or
the associated software.
Companies, names, and data used in examples herein are fictitious unless otherwise noted. No part of this document
may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, nor
transferred to any other media or language without the written permission of Cognex Corporation.
Copyright © 2016. Cognex Corporation. All Rights Reserved.
Portions of the hardware and software provided by Cognex may be covered by one or more U.S. and foreign patents, as
well as pending U.S. and foreign patents listed on the Cognex web site at: http://www.cognex.com/patents.
2
Table of Contents
Table of Contents
Legal Notices 2
Table of Contents 3
Symbols 5
Getting Started 6
About DataMan 150 6
DataMan 150 Accessories 8
Lens Options 8
Filters 9
Lens Covers 9
Light Options 9
Cables 10
Power Supplies 10
Mounting Brackets 10
IO Modules 11
DataMan 150 Systems 12
Communication Modules 13
DataMan 150 Cable Pinouts 13
USB Connections 14
RS-232 Connections 14
RS-232 Cable 15
Reader Layout 16
Indicator LEDs 16
Dimensions 17
3
Table of Contents
Acquisition Triggering 41
I/O Cable Specifications 41
Flying Leads Cable 43
Multi-port Connections 50
Precautions 52
Regulations/Conformity 53
For European Community User 53
4
Symbols
Symbols
The following symbols indicate safety precautions and supplemental information.
WARNING: This symbol indicates the presence of a hazard that could result in death, serious personal injury or
electrical shock.
CAUTION: This symbol indicates the presence of a hazard that could result in property damage.
Tip: Tips provide helpful suggestions and shortcuts that may not otherwise be apparent.
5
Getting Started
Getting Started
This section provides general information about the DataMan 150 series readers as well as about the DataMan 150
accessories and systems.
The DataMan 150 readers are best in class ID readers, offering superior performance with the latest ID tools, flexibility to
configure the reader in terms of lighting and optics to optimize the application, and an ease-of-use giving the user the
ability to setup and deploy an application quickly and efficiently all without the need for PC:
l Superior performance, 1-D and 2-D code reading, including HotBars2™ and patent-pending PowerGrid™
l Flexible optics/lighting, including field upgrades, allowing for the protection of your investment
l Ease-of-use, including an auto-tune and trigger button on the reader, the ability to configure the reader in a
straight or right-angle orientation and auto-focus capability utilizing a liquid lens
The DataMan 150 readers provide support for Ethernet and RS-232 communications.
Key highlights:
l 1DMax with HotBars2™, best in class 1-D reading, 2DMax with PowerGrid™, best in class 2-D reading. Reading
codes no other ID reader on the market can.
l Multiple options for LED lighting, along with optical filters and polarizing filters. Options for different powered lens,
with autofocus capabilities for each.
l Intelligent tuning and dynamic configuration of the reader combined to make the installation and setup of the
application a snap.
This document provides basic information about how to configure and use DataMan 150 readers. Additional information
is available through the Windows Start menu or the DataMan Setup Tool Help menu after you install the DataMan
software on your PC:
l The DataMan Communications & Programming Guide shows how to integrate your DataMan reader with your
automation software and factory network.
Cognex->DataMan Software v x.x.x->Documentation->Communications And Programming
l The DataMan Reader Configuration Codes document provides printable 2-D codes that you can use to
configure the DataMan reader.
Cognex->DataMan Software v x.x.x->Documentation->English->Reader Configuration Codes
l The DataMan Fixed Mount Readers Reference is a complete online hardware reference for the DataMan fixed-
mount ID readers.
Cognex->DataMan Software v x.x.x->Documentation->English->DM150 ->Fixed Mount Reference Manual
6
Getting Started
l The DataMan Questions and Answers document provides context-sensitive information. You can view this help
inside the DataMan Setup Tool or as a stand-alone help file.
Cognex->DataMan Software v x.x.x->Documentation->DM150DM->Questions and Answers
l The Release Notes list detailed system requirements and additional information about this DataMan software
release.
Cognex->DataMan Software v x.x.x->Documentation->DataMan v x.x.x Release Notes
7
Getting Started
Lens Options
6.2 mm lens kit (DM150-LENS-62)
16 mm lens with extended optics mount (requires the use of an extended front cover and
high-powered red LED) (DM260-LENS-16)
l 16 mm optics mount
l 16 mm lens
l manual lens cap (assembled)
l screws
Liquid Lens Module (LLM) to be used with 6.2 mm lens or 16 mm lens (DMA-LLM-150-
260)
l 16 mm lens
l Liquid Lens Module (DMA-LLM-150-260)
l High Powered red LED illumination (DM260-LED-RED-HP)
l 2-LED half-polarized extended cover (DM260-LENS-16CVR-P)
8
Getting Started
Filters
Blue bandpass filter
(DM150-BP470)
Lens Covers
Clear lens cover (DM150-CVR-CLR)*
Light Options
Red LED illumination (DM150-LED-RED)*
9
Getting Started
Cables
5-meter extension cable* (DM100-EXTCBL-000)
Power Supplies
Power supply, 6V (DM100-PWR-000)
Mounting Brackets
Mounting bracket (DM100-UBRK-000)
10
Getting Started
IO Modules
DataMan Basic I/O Module (DM100-IOBOX-000)
11
Getting Started
DataMan √ √ √ 752x480
150S1 Global
shutter
DataMan √ √ 752x480
150QL Global
shutter
DataMan √ √ √ 752x480
150Q Global
shutter
DataMan √ √ √ √ 752x480
150X Global
shutter
DataMan √ √ √ 1280x960
152S2 Global
shutter
DataMan √ √ 1280x960
152QL Global
shutter
DataMan √ √ √ 1280x960
152Q Global
shutter
DataMan √ √ √ √ 1280x960
152X Global
shutter
12
Getting Started
Communication Modules
The DataMan 150 is available with the following communication options:
l USB/RS-232
The I/O module with USB has all signals on a SUB-D 15 connector with the following pinouts:
Note: Pin numbers are shown for cable connector, not I/O module.
13
Getting Started
USB Connections
When connected to a PC over USB, the DataMan 150 appears as a COM port.
You can connect your device to the computer in the following ways:
Connect directly to the PC: Connect to the PC through a basic I/O module:
If the reader is configured as an HID device and you want to return to USB serial, scan the USB serial connection code:
Note: The DataMan PC software must be installed for this connection type!
RS-232 Connections
You can connect the DataMan 150 reader to a PC or other device over a standard RS-232 serial connection.
Note: You must supply external power to use this connection type.
14
Getting Started
Connect directly to the PC: Connect to the PC through a basic I/O module:
RS-232 Cable
You can connect a cable with RS-232 & flying leads (DM-RS232IO-00) to the cable that is attached to the device. The
following table shows the pinout and color description of the flying leads.
15
Getting Started
Reader Layout
The following images shows the built-in lighting system and other features of the DataMan 150.
1 Illumination LEDs
2 LED aimers
3-4* Mounting holes (M3 x 3.5mm)
5 Trigger button
6 Power indicator
7 Train status/Trigger status indicator
8 Good/bad read
9 Communication
10 Error indicator
11 Tune button
12 Power, I/O and RS-232 connector
Note: *Use only one set of mounting holes (either 3 OR 4) for mounting.
Note: The five status LEDs together also function as a peak meter using an orange light.
Indicator LEDs
Type Signal Color Meaning
Status Power GREEN Power ON
Train status GREEN Trained
YELLOW Untrained
Error RED Error - check device log
Action Good/bad read GREEN Good read
RED Bad read
Network YELLOW Link up
blink Data transfer
Peak meter Yellow Tune
Focus
16
Getting Started
Dimensions
The DataMan 150 consists of three main parts:
1. Optics module (lens including lens mount, illumination and front cover including filter mounting option for a
Diameter (Ø): 12.3mm<Ø<12.7mm, Thickness (t): 1.6mm<t<2mm filter)
2. Main module, including sensor and CPU
3. I/O module
17
Getting Started
The size of the DataMan 150 in the straight configuration is shown in the following figure:
The size of the DataMan 150 in the angled configuration is shown in the following figure:
18
Getting Started
19
Setting Up Your DataMan 150
Mounting
Mounting the DataMan 150 at a slight angle (15°) can reduce reflections and improve reader performance.
20
Setting Up Your DataMan 150
Note: Disconnect the DataMan 150 reader from power before changing lenses.
WARNING: This modification must be made in a dust-free and ESD safe area.
1. Remove the front cover: unscrew the four M2x12mm Phillips Pan head screws and take off the LED cover.
3. Unscrew the two M2x5mm Phillips head screws and remove the 6.2 mm lens mount.
21
Setting Up Your DataMan 150
5. Fasten the two M2x5mm Phillips head screws to 0.06 Nm using a torque wrench.
6. In the case of a manual focus lens, press the 16 mm lens cap onto the lens. The lens has 12 cutouts so it can be
locked in steps of 30 degrees.
In the case of a liquid lens, mount the liquid lens cap onto the 16 mm lens. (See Installing a Liquid Lens on
page 27.)
7. Attach the illumination board.
Note: Take care to attach the illumination with the right orientation.
22
Setting Up Your DataMan 150
8. Attach the front cover. Observing the tightening sequence below, tighten all four M2x25 Phillips Pan head screws
to 9 Ncm using a torque wrench.
Note: The rib in the front cover must be oriented to the top side.
23
Setting Up Your DataMan 150
Note: Disconnect the DataMan 150 reader from power before changing to an illumination with a different color.
1. Remove the front cover: unscrew the four screws and take off the LED cover.
Note: Take care to attach the illumination with the right orientation.
24
Setting Up Your DataMan 150
4. Attach the front cover. Observing the tightening sequence below, tighten all four screws to 9 Ncm using a torque
wrench.
Note: The rib in the front cover must be oriented to the top side.
Note: Disconnect the DataMan 150 reader from power before installing an optical filter.
1. First, remove the front cover: unscrew the four M2x12mm Phillips Pan head screws and take off the LED cover.
25
Setting Up Your DataMan 150
2. Insert the filter at the bottom side of the round opening in the transparent plastic part.
3. Push the top side of the filter firmly until it is sitting flat against the PCB.
Note: Use finger to push the filter in and then a q-tip to clean the filter, or use a q-tip to push the filter into
place.
4. Attach the front cover. Observing the tightening sequence below, tighten all four M2x12mm Phillips Pan head
screws to 9 Ncm using a torque wrench.
Note: The rib in the front cover must be oriented to the top side.
26
Setting Up Your DataMan 150
Note: Disconnect the DataMan 150 reader from power before installing the liquid lens.
1. Remove the front cover: unscrew the four M2x12mm Phillips Pan screws and take off the LED cover.
4. Remove the lens cap from the imager lens by pulling it.
Note: Do not rotate the imager lens while the lens cap is removed. Otherwise, focus calibration will be lost.
27
Setting Up Your DataMan 150
5. Attach the liquid lens accessory by aligning the 2x2 connectors of the liquid lens with the 2x2 sockets on the
optics mount.
6. Press the liquid lens onto the imager lens until you reach the stop.
8. Attach the front cover. Observing the tightening sequence below, tighten all four M2x12mm Phillips Pan screws to
9 Ncm using a torque wrench.
Note: The rib in the front cover must be oriented to the top side.
Note: The DataMan 150 liquid lens must be calibrated after field exchange. This can be done under Focus
Settings in the DataMan Setup Tool. For more information, see the DataMan Questions and Answers
document. A reboot is required for the lens to operate with the new settings.
28
Setting Up Your DataMan 150
DM152
The following maps show the FoV of the DataMan 150 readers with a 6.2 mm lens. The horizontal and vertical field of
view is shown for working distances of 40 mm, 65 mm and 105 mm.
29
Setting Up Your DataMan 150
DM152
The following maps show the FoV of the DataMan 150 readers with a 6.2 mm lens. The horizontal and vertical field of
view is shown for working distances of 150 mm, 190 mm, 225 mm, 375 mm and 500 mm.
30
Setting Up Your DataMan 150
31
Setting Up Your DataMan 150
DM152
The following maps show the FoV of the DataMan 150 readers with a 16 mm lens. The horizontal and vertical field of
view is shown for working distances of 80 mm, 150 mm, 225 mm, 375 mm, 500 mm and 1000 mm.
32
Setting Up Your DataMan 150
Tuning
By tuning, your DataMan 150 reader automatically selects the best settings for the given reading situation, based on
parameters of illumination, camera and decoder properties, and focal distance. Tuning autodiscriminates all enabled
symbologies (both 1-D and 2-D). If multiple symbols are found in the field of view, tuning locks on the first one found. Use
this feature to create an optimum setting to read your codes.
You can use any of the following methods to tune your reader:
Press the Tune button ( ) at least for 3 seconds on your reader. The first press starts the tuning and the second
press cancels the tuning, if it is still ongoing.
Start tuning by sending a DMCC, for more information, see the Command Reference, available through the Windows
Start menu or the DataManSetup Tool Help menu.
Use Input line 1 for tuning. Go to the System Settings pane in the DataManSetup Tool and check Tune. You can also
use the In1 button on the toolbar.
33
Setting Up Your DataMan 150
Imager Specifications
Specification DataMan 150 Imager DataMan 150 Imager
Image Sensor 1/3 inch CMOS 1/3 inch CMOS
Image Sensor 4.51 mm x 2.88 mm (W x H), 6.0 μm square 4.8 mm x 3.6 mm (W x H), 3.75 μm square
Properties pixels pixels
Image Resolution 752 x 480 1280 x 960
(pixels)
Lens Type S-mount 6.2 mm F:5 (with optional liquid lens)
S-mount 16 mm F:7 (with optional liquid lens)
34
Setting Up Your DataMan 150
Illumination Options
Illumination USB Powered PoE Powered 24V Externally Powered
Board Max. exposure Max. duty Max. exposure Max. duty Max. exposure Max. duty
time cycle time cycle time cycle
Standard Red 500 µs 3% 500 µs 3% 1 ms 6%
IR 500 µs 3% 500 µs 3% 1 ms 6%
35
Using Your DataMan 150
1. Check the DataMan Release Notes for a full list of system requirements.
2. Download the DataMan Setup Tool from http://www.cognex.com/support/dataman and follow the on-screen
steps.
3. Connect the DataMan 150 to your PC.
4. Choose Start > Programs > Cognex > DataMan Software vx.x.x > Setup Tool to launch the DataMan Setup
Tool. Detected readers will appear under COM ports.
5. Click Refresh to update the list of connected devices.
6. Select the device from the Network list (Discovered Devices) and click Connect.
36
Using Your DataMan 150
2. Using a flathead screwdriver, set the focus position from the front. Always turn clockwise to focus to a larger
distance and counterclockwise to focus to a shorter distance.
Note: If an optical filter has been mounted, first disconnect the DataMan 150 reader from power and remove
the illumination module with the filter before adjusting the focus.
3. Remount the front cover. Observing the tightening sequence below, tighten all four screws to 9 Ncm using a
torque wrench.
Note: If you use an optical filter and the illumination was removed, remount the illumination module first and
then remount the front cover.
Note: The rib in the front cover must be oriented to the top side.
37
Using Your DataMan 150
l Single: Acquires a single image and attempts to decode any symbol it contains or more than one symbol in cases
where multicode is enabled. The reader relies on an external trigger source.
l Presentation: Repeatedly scans for a symbol and decodes it whenever one is detected. The reader relies on an
internal timing mechanism to acquire images.
l Manual (default): Begins acquiring images when you press the trigger button on the reader or the discrete trigger
input is activated, and continues acquiring images until a symbol is found and decoded or you release the button
or the discrete trigger input is deactivated.
l Burst: Performs multiple image acquisitions based on an external trigger and decodes one or multiple symbols
appearing in the sequence of images.
l Self: Similar to Presentation mode in that the reader perpetually scans for symbols and decodes them each time
one is detected. Unlike Presentation mode, however, Self mode supports multicode results and a decode attempt
occurs with every image. The main difference between Self and Presentation is the fixed and exact interval for
image acquisitions in Self.
l Continuous: Begins acquiring images based on a single external trigger and continues to acquire images until a
symbol is found and decoded, or until multiple images containing as many codes as specified in multicode mode
are located, or until the trigger is released.
l Single trigger
l Burst mode
l Self trigger
l Continuous mode
Training
Training your reader with the expected symbology may help increase decode yield. To train your reader, place a code in
front of the reader and do one of the following:
l Press and hold the trigger button ( ) for at least 3 seconds and the release it.
l Click and hold the trigger button in the DataMan Setup Tool ( ) for at least 3 seconds and then release it.
l Click Train Code in the Action ribbon of the DataMan Setup Tool.
If using Single trigger mode, upload the code through File -> Train Image.
38
Using Your DataMan 150
Note: You can use training in Single, Burst, Continuous or Self trigger modes. Only a single symbol of each kind of
symbology can be trained per read setup.
DataMan 150 reports the status of the training and brightness optimization operations using its signaling LEDs. The
second LED from left on the reader flashes green to indicate that the reader is currently trained, or yellow to indicate that
it is not trained.
Connect the reader to the DataMan Setup Tool to untrain it and allow it to recognize other enabled symbologies.
39
Using Your DataMan 150
With incremental training enabled, you can train the reader using multiple images showing the symbologies you expect
to decode. The reader will train each new symbology while retaining the existing trained symbologies.
40
Connections, Optics and Lighting
Acquisition Triggering
To trigger from an NPN (pull-down) type photo-detector or PLC output, connect to +24V and connect Into the output of
the detector. When the output turns on, it pulls Common In down to 0V, turning the opto-coupler on.
To trigger from a PNP (pull-up) photo-detector or PLC output, connect to the output of the detector and connect to 0V.
When the output turns on, it pulls In 0 up to 24V, turning the opto-coupler ON.
Note: GND (Pin 4) is connected to the reader housing, cable shield, and DB15 shell.
41
Connections, Optics and Lighting
9 White/Black Input-1
11 Light Blue/Black Output-1
12 Light Blue/Yellow Output-Common
13 Light Blue/Green Input-Common
42
Connections, Optics and Lighting
43
Wiring the Basic I/O Module
1. Power: 5-24 VDC, 2.5W peak. Connect either ground pin to chassis ground.
2. Discrete output: Opto-isolated, current source or sink, depending on wiring; must connect logical ground to
common. Outputs are opto-isolated and protected against reverse polarity. Max current 50 mA @ 24 VDC. Output
1 used for external illumination control by default.
3. Trigger input: Opto-isolated, polarity-independent, current source or sink; have reference to a separated
common signal. Work with ±15-30V. Input 0 is dedicated trigger line.
Note: You must use a null modem cable when connecting the Basic I/O Module to a PC’s RS-232 serial port.
44
Wiring the Basic I/O Module
45
Digital Input Wiring Diagrams
Load to a TTL Buffer
46
Digital Input Wiring Diagrams
PNP Configuration
NPN Configuration
47
Digital Output Wiring Diagrams
48
Digital Output Wiring Diagrams
49
Multi-port Connections
Multi-port Connections
You can connect multiple DataMan 150 readers to a single PC (or other device equipped with a serial port) using a
multi-port connection.
A multi-port connection creates a daisy-chain of readers. Each reader receives serial data from the previous reader and
transmits it to the next reader. When a reader transmits data, it is passed through each of the readers in the chain
between it and the PC.
You must construct your own cable that meets the requirements of your system configuration.
The cable must provide a DB-15 connector for each DataMan 150 and a DB-9 connector for the PC serial port. Each DB-
15 connector must provide Tx Data, Rx Data, Trigger (Input 0), ground, and DC power. The Tx Data and Rx Data pins on
adjacent connectors must be connected to provide the multi-port connection.
The following diagram shows how to create a multi-port cable for a 3-reader system. In the example, all the readers
share a common trigger. It is also possible to wire individual triggers for each reader.
50
Multi-port Connections
You must connect each DataMan 150 to DataMan Setup Tool using a USB connection and set the DataMan for multi-
port operation. To configure a DataMan 150 for multi-port operation, click on the Enable Multi-Port (RS-232 Sharing)
check box in Communication Settings.
There is no guaranteed delivery order when multiple readers transmit data using a multi-port connection; read results
may arrive at the PC in any order. You can configure each DataMan 150 reader in a multi-port connection to add
identifying data to each read result. Your PC application can then determine which reader produced a specific read
result.
To do this, check the Standard Formatting Enabled box (for each symbology that you are using) in Data Formatting,
and enter text in the Leading Text field. (You can also add trailing text by entering text in the Trailing Text field.)
You can obtain the best results when using multi-port connections by keeping the following usage guidelines in mind as
you design your system:
l The maximum cable length between any two DataMan 150 readers or between the PC and any DataMan reader
should be no greater than 15 meters.
l There is no fixed limit to the number of DataMan 150 readers that you can connect to a single PC. Each reader
introduces a delay of about 100 ms when it retransmits received serial data. If you have 5 readers, this means
that there will be a 400 ms delay between the time the first reader in the chain transmits data and the PC receives
it.
l Each DataMan 150 reader must receive a hardware trigger signal on its Input 0 line. You can wire the input ports
to a common trigger signal or you can provide individual triggers for each reader.
l Each DataMan 150 reader must be individually configured for multi-port operation, and you must perform this
configuration using a USB connection.
l If any reader in the multi-port chain loses power or becomes disconnected, then no data from any other reader
will be transmitted.
l If a DataMan 150 is transmitting its own read result, it will buffer any data received from another reader until it has
finished its own data transmission. If a DataMan 150 is transmitting another reader’s data, it will buffer its own
data if it receives a trigger signal while it is processing the other reader’s data.
l If you use a single power supply for multiple readers, make sure that the power supply can provide enough
power for all of the readers.
51
Precautions
Precautions
Observe these precautions when installing the Cognex product, to reduce the risk of injury or equipment damage:
l This device requires the use of an LPS or NEC class 2 power supply.
l Do not connect or disconnect this device from the I/O module or 15-pin USB adapter cable while the I/O module
or adapter cable is connected to a PC .
l To reduce the risk of damage or malfunction due to over-voltage, line noise, electrostatic discharge (ESD), power
surges, or other irregularities in the power supply, route all cables and wires away from high-voltage power
sources.
l Changes or modifications not expressly approved by the party responsible for regulatory compliance could void
the user’s authority to operate the equipment.
l Cable shielding can be degraded or cables can be damaged or wear out more quickly if a service loop or bend
radius is tighter than 10X the cable diameter. The bend radius must begin at least six inches from the connector.
l Class A Equipment (broadcasting and communication equipment for office work): Seller and user shall be
notified that this equipment is suitable for electromagnetic equipment for office work (Class A) and can be used
outside the home.
l This device should be used in accordance with the instructions in this manual.
l All specifications are for reference purpose only and may be changed without notice.
52
Regulations/Conformity
Regulations/Conformity
The DataMan 150 has Regulatory Model 1AA3 and meets or exceeds the requirements of all applicable standards
organizations for safe operation. However, as with any electrical equipment, the best way to ensure safe operation is to
operate them according to the agency guidelines that follow. Please read these guidelines carefully before using your
device.
Regulator Specification
USA FCC 47 CFR Part 15 Subpart B, Class A
Canada ICES-003
European Community EN55022 (CISPR 22) Class A
EN55024:1998 +A1:2001 +A2: 2003
EN60950
Australia C-TICK, AS/NZS CISPR 22 / EN 55022 for Class A Equipment
Japan J55022, Class A
Note: For the most up-to-date regulations and conformity information, please refer to the Cognex online support
site: http://www.cognex.com/Support.
CAUTION: This device requires the use of a PoE Class 1 or 48V DC LPS power supply.
UL and cUL UL and cUL listed: UL60950-1 1st ed. and CSA C22.2 No.60950-1 1st ed. Certified to CB scheme IEC
Statement 60950-1:2001 1st ed.
53
Regulations/Conformity
In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural
resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or
recycle most of the materials of the product you are disposing in a sound way.
The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal
waste and invites you to use the appropriate separate take-back systems for product disposal.
If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste
administration.
You may also contact your supplier for more information on the environmental performance of this product.
54