UPS Vertiv GXT2000
UPS Vertiv GXT2000
y Generator-compatible with
wide input frequency range
(40 to 70 Hz)
y Class A electromagnetic
interference (EMC) The Liebert® GXT MT+ has a comprehensive Desktop Computing
specification that provides a higher level of y Liebert® PSP
y Ultra wide input voltage range availability to the IT equipment. It satisfies
y Liebert® PSA
safety criteria and electromagnetic
y High input power factor & low compatibility standards while offering y Liebert® itON BX
THDi intelligent monitoring and network
management functions. This high Network / Computer Room
y Emergency power off (EPO) performance UPS with proven reliability is y Liebert® GXT MT+ H
y Configurable to energy saving available in a compact tower design.
y Liebert® PSI
mode (ECO)
y Liebert® GXT3
Bringing our Enterprise Level IT Expertise
y LCD display for operational
to your SMB
convenience and status / fault Data Center
information Vertiv offers a full range of power protection y Liebert® APM
solutions suitable for every requirement or y Liebert® NX
y Multiple AC output NEMA
scenario. From desktop computing, network
interfaces with Programmable y Liebert® Hipulse
equipment, computer rooms to large scale
output
data centers, we make sure you get the
y Remote Monitoring is available same level of protection the Fortune 500
through USB / RS232, and companies enjoy with Vertiv. It is our way of
optional via dry contacts and Bringing Enterprise Level IT expertise to
SNMP your SMB.
Vertiv.com
Liebert® GXT MT+ (1kVA - 3kVA)
Technical Specifications
System Features
Part Number Standard Model GXT-1000MTPLUS230H GXT-2000MTPLUS230H GXT-3000MTPLUS230H
Capacity (VA/W) 1000 / 800 2000/1600 3000/2400 Applications
Input Parameters
Frequency Range 40Hz - 70Hz (50Hz/60Hz auto sensing)
y Small-size Data Center
Phase Single phase with ground
Power Factor ≥ 0.99 @ 220 to 230 VAC (input voltage) y Telecommunication Equipment
Voltage Range
Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC y VoIP
High Line Transfer 300 VAC ± 5%
y Small Office Network
Output Parameters
Output Voltage 208/220/230/240VAC y Computer Rooms
AC Voltage Regulation ± 1% (Batt. Mode)
Frequency Range 47 to 53 Hz or 57 to 63 Hz (Auto Sensing)
y Process Automation Equipment
Frequency Range (Batt. Mode) 50 Hz ± 0.25Hz
y Network Storage Devices
Overload 100% to 110%: audible warning 110% to 130%: UPS shuts down in 30
seconds at battery mode or transfers to bypass mode when the utility
is normal. >130%: UPS shuts down immediately at battery mode or
transfer to bypass mode when the utility is normal.
Efficiency 50 17 16 12
AC Mode ~ 85% ~ 88% 75 10 10 7
Battery Mode ~ 83% 90 7 7 5
100 6 6 4
Transfer Time
AC Mode to Batt. Mode Zero
Inverter to Bypass 4 ms (Typical)
Physical Parameters
Dimension, 220 x 145 x 397 318 x 190 x 421
DxWxH
Net Weight (kgs) 13 7 26 13 28 13
Environmental Parameters
Operation Humidity 20 to 90 % RH @ 0 to 40°C (non-condensing)
Noise Level Less than 55dBA @ 1 Meter
Agency Approval
Safety IEC/EN 62040-1, CE Mark
EMC Directives IEC/EN 62040-2 (EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11,
EN61000-2-2: 2002, EN61000-3-2, EN61000-3-3)
Management
Smart RS-232 or USB Supports Windows 98/2000/2003/XP/Vista/2008/ 7, Linux, and MAC
Optional SNMP Power management from SNMP manager and web browser
Vertiv.com
© 2021 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While
every precaution has been taken to ensure accuracy and completeness here, Vertiv Group Corp. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications, rebates and other
promotional offers are subject to change at Vertiv’s sole discretion upon notice.