Cantilever Slab Design
Cantilever Slab Design
Input slab Id F9
Characteristic cube strength of concrete fck = 20 N/mm2
Characteristic strength of steel fy = 500 N/mm2
Cantilever Projection L = 1.1 m
Over all Depth of slab @ support Ds = 127 mm
Over all Depth of slab @ Free end De = 127 mm
Floor finish load FF = 1.00 KN/m2
Live load LL = 2.0 KN/m2
UDL at Free End P = 9.0 KN/m
diameter of main reinforcement Φ1 = 10 mm
spacing of main reinforcement S1 = 150 mm
diameter of distribution reinforcement Φ2 = 8 mm
spacing of main reinforcement S2 = 150 mm
clear cover to Main reinforcement c = 20 mm
Anchorage length Ld = 600 mm
Modification factor for Tension rft. kt = 1.8 Fig 7.2
Modification factor for Compression rft. kc = 1
Ratio web width to flange width kf = 1
τbd = 2 Mpa Cl. 26.2.1.1
Load & Ultimate Moments
self weight of slab SW =0.5(Ds+De)*γc/1000
=0.5×(127+127)×25/1000 = 3.2 KN/m2
Ultimate Bending moment Mu =(1.5DL+1.5LL)*L^2/2+1.5*P*L
=1.5×(3.2+1.0+2.0)×1.1^2/2+1.5×9.0×1.1 = 19.7 KN/m2
Check for depth
effective depth d =Ds-c-Φ1/2
=127-20-10/2 = 102.0 mm
Minimum depth required for flexure dreq. =√(M/fck*b*d)
=sqrt(19.7×10^6/(0.138×20×1000)) = 84.4 mm OK
Reinforcement details
R =Mu/bd^2
=19.7×10^6/(1000×102.0^2) = 1.89 Mpa
Percentage of steel required Pt req =(1-√1-4.589*R/fck)*fck/(2*fy)
=(1-sqrt(1-4.589×1.89/20))×20/(2×500) = 0.0050
Area of tensile reinforcement required Ast req. =Pt req.*b*d
=0.005×1000×102.0 = 505 mm2/m
Minimum Area of tensile steel Ast min =0.12*b*d/100
=0.12×1000×102.0/100 = 122 mm2/m
Spacing of main reinforcement req. S1 req. =1000*π*(Φ1^2/4)/max(Ast req,Ast min)
=1000×(3.14×10^2/4)/max(505/122) = 155 mm
< 150 mm OK
Area of tensile reinforcement Provided Ast Pro =1000×(3.14×10^2/4)/150 = 523 mm2/m
Distribution steel
Area of distribution steel required Ast. Dist =0.12×1000×102.0/100 122 mm2/m
Spacing of distribution reinforcement req. S2 req =1000×(3.14×8^2/4)/122 410 mm2/m
Spacing of distribution steel provided S2 Prov. < 150 mm OK
Anchorage Length
Anchorage length required Ld req. =0.87×500×10/(4×1.92) = 566 mm
Anchorage length required Ld prov. > 600 mm OK
Check for deflection control
Percentage of tensile steel provided Pt =100×523/(1000×102.0) = 0.513
Allowable Span/depth ratio L/d max =L/d basic*kt*kc*kf
=(7×2×1×1) = 13
Span/depth provided L/d Pro. < 10 OK