0% found this document useful (0 votes)
78 views

Lab Manual-Aircon System-Level 2-Trendline

This document provides information for a laboratory manual on an air conditioning system experiment. The objectives are for students to understand the operation of an air conditioning system and use a psychrometric chart. The document outlines the theoretical background on air conditioning components like the refrigerant, compressor, condenser, expansion valve and evaporator. It describes the apparatus used, procedures for students to run the air conditioning demonstration unit, and what data to acquire. Students are required to submit a technical report analyzing results, sketching the system, plotting a psychrometric chart, and calculating air flow and efficiency.

Uploaded by

tasha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views

Lab Manual-Aircon System-Level 2-Trendline

This document provides information for a laboratory manual on an air conditioning system experiment. The objectives are for students to understand the operation of an air conditioning system and use a psychrometric chart. The document outlines the theoretical background on air conditioning components like the refrigerant, compressor, condenser, expansion valve and evaporator. It describes the apparatus used, procedures for students to run the air conditioning demonstration unit, and what data to acquire. Students are required to submit a technical report analyzing results, sketching the system, plotting a psychrometric chart, and calculating air flow and efficiency.

Uploaded by

tasha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

FAKULTIKEJURUTERAAN AWAM

UNIVERSITI TEKNOLOGI MARA


SHAHALAM LABORATORY MANUAL

MECHANICAL AND ELECTRICAL


COURSE
ENGINEERING PRACTICE
COURSE CODE ECM 433

LEVEL OF OPENNESS 2

CATEGORY PARTIALLY OPEN ENDED

DEGREE OF OPEN-ENDED (%) 66

PERIOD OF ACTIVITY 1WEEK

I TITLE I AIRCONDITIONING SYSTEM (C02,P08)

1.1 Introduction

Air conditioning units are used to remove heat from the building so that we
can maintain a cool and comfortable internal environment. Heat flows into
a building through walls, roofs and windows by conduction and radiation.
People, equipment and appliances inside the building also generate heat.
Accumulation of heat will raise the air temperature inside the building.

1.2 Objective
The objective of the test is:

Student will run the air conditioning unit system and part of this system
and identified the system operation including part involve.

PREAMBLE
1.3 Learning Outcomes
At the end of the laboratory activities, students would be able to:
i. Explain the operation of air conditioning system
iii. Know how to used psychometric chart and the
application of air conditioning system through
heat transfer

1.4 Theoretical Background


Theoretical Background shall be referred to introductions and lecture
notes
t:=AKULTI KEJURUTERAAN AWAM
UNIVERSITI TEKNOLOGI MARA
SHAH ALAM LABORATORY MANUAL

Main component in the air conditioning system are :


1) Refrigerant
2) Compressor
3) Condenser
PROBLEM STATEMENT
4) Expansion valve
5) Evaporator
How this system does operates.

3.1 Apparatus

1. Air conditioning demonstration unit

3.2 Procedures

i. Prepare the air conditioning system unit and


follow instruction from instructor
WAYS&MEANS

3.3 Data Acquisition

Dry bulb temperature, wet bulb temperature and Ammeter at


the air-con demonstration unit.

4 Results, Analysis and Conclusion


The group is required to submit the technical report of the laboratory
results.

The report must incorporate the followings:


i. Discuss the result of time taken during the experiment.
RESULTS ii. Sketch the air conditioning unit system and name each
of their component
ii. Plot the trendline in the psyrometric chart and state the
process and the value (specific enthalply and moisture
content and etc.
iii. Calculate the air flow (mmhg) in the air-conditioning system by
using psychometric chart
iv. Calculate the efficiency of the boiler (pre-heating) used in this air-
con demonstration unit
The report must be submitted 7 days after the completion of the test.