0% found this document useful (0 votes)
63 views

Duraflow PVC

This document specifies the requirements for schedule 80 unplasticized polyvinyl chloride (UPVC) pressure pipe as described in ASTM D-1785. It outlines the material used, dimensions and tolerances, markings, and provides a table with nominal pipe sizes ranging from 1/8 inch to 24 inches that lists dimensions such as outer diameter, inner diameter, wall thickness, weight per foot, and maximum working pressure.

Uploaded by

von18
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views

Duraflow PVC

This document specifies the requirements for schedule 80 unplasticized polyvinyl chloride (UPVC) pressure pipe as described in ASTM D-1785. It outlines the material used, dimensions and tolerances, markings, and provides a table with nominal pipe sizes ranging from 1/8 inch to 24 inches that lists dimensions such as outer diameter, inner diameter, wall thickness, weight per foot, and maximum working pressure.

Uploaded by

von18
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

UPVC schedule 80 pipe

Scope :This specification covers requirements for accordingto Method D-2122. Tolerances for out
schedule 80 UPVC pressure pipe as described in of-roundness shall apply only to pipe prior to
ASTM D-1785.
shipment.
Material : UPVC used is Type l, Grade I
compound, cellclassification 12454-B per ASTM Marking: Indicates manufacturer's name, material
D-1784. designation code, nominal pipe size, schedule
Dimensions : Dimensions and tolerances shall be size with pressure rating in PSI for water at 73°F,
as shown in the following tables when measured ASTM designation number D-1785.
Schedule 80 Dimensions
(unit):inch
Nom Pipe Average Min. Nom. Max
O.D. W.P. PSI Code
Size(in). I.D. Wall Wt./Ft.
1/8 0.405 0.195 0.095 0.063 1230 11-PIO-08-0003

1/4 0.540 0.282 0.119 0.105 1130 11-PIO-08-0008

3/8 0.675 0.403 0.126 0.146 920 11-PIO-08-0010

1/2 0.840 0.526 0.147 0.213 850 11-PIO-08-0015

3/4 1.050 0.722 0.154 0.289 690 11-PIO-08-0020

1 1.315 0.936 0.179 0.424 630 11-PIO-08-0025

1-1/4 1.660 1.255 0.191 0.586 520 11-PIO-08-0032

1-1/2 1.900 1.476 0.200 0.711 470 11-PIO-08-0040

2 2.375 1.913 0.218 0.984 400 11-PIO-08-0050

2-1/2 2.875 2.290 0.276 1.500 420 11-PIO-08-0065

3 3.500 2.864 0.300 2.010 370 11-PIO-08-0080

3-1/2 4.000 3.326 0.318 2.452 350 11-PIO-08-0090

4 4.500 3.786 0.337 2.983 320 11-PIO-08-0100

5 5.563 4.768 0.375 4.078 290 11-PIO-08-0125

6 6.625 5.709 0.432 5.610 280 11-PIO-08-0150

8.625 7.565 0.500 8.522 250 11-PIO-08-0200

10 10.750 9.493 0.593 12.635 230 11-PIO-08-0250

12 12.750 11.294 0.687 17.384 230 11-PIO-08-0300

14 14.000 12.410 0.750 20.852 220 11-PIO-08-0350

16 16.000 14.231 0.843 26.810 220 11-PIO-08-0400

18 18.000 16.014 0.937 33.544 220 11-PIO-08-0450

20 20.000 17.814 1.031 41.047 220 11-PIO-08-0500

24 24.000 21.418 1.218 58.233 210 11-PIO-08-0600