The ANDiS Monkeypox virus nucleic acid Detection kit (Fluorescence PCR) is an in vitro real-time polymerase chain reaction (PCR) assay that can accurately and reliably detect monkeypox virus nucleic acid from lesion swab samples with a limit of detection of 200 copies/ml. It provides automated nucleic acid extraction and fast results within 30 minutes on supported instruments to aid in the diagnosis of monkeypox virus infections from suspected patients. The kit containing 8 or 9 tests can work automatically on instruments like the Bio-Rad CFX-96 or ABI QuantStudio 5 for analysis to help treat and control the recent spread of monkeypox virus.

Uploaded by

Davi Muhammad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views2 pages

猴痘 (220602) Monkeypox

The ANDiS Monkeypox virus nucleic acid Detection kit (Fluorescence PCR) is an in vitro real-time polymerase chain reaction (PCR) assay that can accurately and reliably detect monkeypox virus nucleic acid from lesion swab samples with a limit of detection of 200 copies/ml. It provides automated nucleic acid extraction and fast results within 30 minutes on supported instruments to aid in the diagnosis of monkeypox virus infections from suspected patients. The kit containing 8 or 9 tests can work automatically on instruments like the Bio-Rad CFX-96 or ABI QuantStudio 5 for analysis to help treat and control the recent spread of monkeypox virus.

Uploaded by

Davi Muhammad
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ANDiS Monkeypox virus

nucleic acid Detection kit


(Fluorescence PCR)

Features

Accurate Automated
LoD 200 copies/ml Automated DNA extraction
and detection

Reliable Fast Result


Endogenous IC for whole process 30min on Q5
operation monitoring

About Monkeypox

Orthopoxvirus monkeypox, first isolated in 1958 from captive primate rash specimens, was
recognized to cause human illness in 1970 during smallpox eradication campaign intensification.
There are two main branches of monkeypox virus: the West African branch and the Congo Basin
branch. The West African clade has a lower fatality rate, with about 1% of infections resulting in
death; the Congo Basin clade can cause a 10% mortality rate. Until the 2003 US outbreak, no
human cases had been reported outside of Africa. However, monkeypox virus is spread through
close contact with people, animals or virus-infected substances it has recently spread widely in
many countries.

The use of ANDiS Monkeypox virus nucleic acid Detection kit (Fluorescence PCR) providing fast
results to identify patients infected with monkeypox virus can be an important factor for
monkeypox virus treatment and control.
nten e use
The ANDiS Monkeypox virus nucleic acid Detection kit (Fluorescence PCR) is an in vitro real-time
polymerase chain reaction (PCR) assay for the ualitative detection of monkeypox virus nucleic
acid (DNA) in lesion swab samples. This Assay is intended for use with specimens from patients who
are suspected of monkeypox virus infections. This assay is intended as an aid in the diagnosis of
monkeypox virus infections when used in con unction with clinical and other laboratory findings.

es r pt on
ecime s A licable strume ts
Lesion swab samples Bio-Rad CF -9 Deep Well Dx Systems
ABI QuantStudio 5 Real-Time PCR Instrument

e siti it eci cit


LoD 200 copies/ml no cross-reaction between other virus
gene and Staphylococcus aureus.

eci catio s
8 Tests/kit, 9 Tests/kit

Auto ate ork o

01 02 03 04
am li A tractio R R ata a al sis
Raw sputum

Lesion swab samples ANDiS350 Automated Nucleic Bio-Rad CF -9 DW or


Acid Extraction System ABI QuantStudio 5
Automated iral Isolation it ANDiS Monkeypox virus
Detection kit

For In itro Diagnostic Use. Not available in all regions and countries.