2023.6.2 Ceiling Columns

The document shows a plan view of column framing for a medical ceiling. It includes dimensions for 8 columns labeled A through I. The columns have heights ranging from 13' to over 20'. Reference numbers are included for beams connecting the columns, such as E2306 and B2304.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
38 views

2023.6.2 Ceiling Columns

The document shows a plan view of column framing for a medical ceiling. It includes dimensions for 8 columns labeled A through I. The columns have heights ranging from 13' to over 20'. Reference numbers are included for beams connecting the columns, such as E2306 and B2304.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

1 2 3

20'-83/8 23'-6
V.I.F V.I.F

15'-1
V.I.F
B

17'-35/8
V.I.F
C

REF#E2302

18'-4
V.I.F

D
18'-7
V.I.F

E
14'-0
V.I.F

REF#E2303
22'-1
V.I.F

G
16'-0
V.I.F

H
13'-0
V.I.F

REV. DATE DESCRIPTION BY CHK


B 06/01/2023 ISSUED FOR RE APPROVAL RMK SKG
A 04/26/2023 ISSUED FOR APPROVAL RMK SKG
I PROJECT:

ASPCA QUEENS CVC


36-02 14TH STREET QUEENS, NY 11106
CONTRACTOR: DESIGNER/OWNER:

- -
FABRICATOR: MAT. SPEC.: HOLES:
N.A. N.A.
H&L IRON WORKS PAINT: WELDING:
N.A. N.A.
11-25 BROADWAY ASTORIA
718-204-1298 DRAWN BY: DATE DRWN:
RMK 05/26/2023
PROJECT NORTH OVERALL MEDICAL CEILING COLUMN FRAMING PLAN - PRIOR TO FABRICATION, DRAWINGS SHOULD BE
DESCRIPTION:
OVERALL MEDICAL CEILING COLUMN PLAN
JOB No.

-
CHCKD BY:
SKG
DATE CHKD:
06/02/2023
REF.DWG.NO: 2/S102 APPROVED BY ARCHITECT OR PROFESSIONAL DRG No.
ENGINEER.
- VERIFY ALL DIMENSIONS WITH ARCHITECT OR
SCE DETAILING GROUP INC.
PROFESSIONAL ENGINEER. 2165 5th Avenue Ronkonkoma, NY 11779 E2301
SCE JOB NO.: - TEL.#(718)-502-9461 FAX#(718)-502-9462
1 2 3
20'-83/8 23'-6
V.I.F V.I.F
2
7'-55/8 7'-55/8 7'-55/8 7'-55/8 7'-55/8 7'-55/8 7'-31/8

E2306

E
1 B2307 W8X18

4'-0
BR2306 L3X3X 1/4

BR2304 L3X3X 1/4

B2305 W8X18
D C2304 HSS4X4X 3/8
E D
E2306 E2306 E2306
EX.BEAM

EX.BEAM

EX.BEAM

EX.BEAM

EX.BEAM
5'-41/2

EX.BEAM
5'-15/8 2'-4

D
4'-91/2

E
B2304 W8X18

BR2303 L3X3X 1/4


4'-0

E2306 SIM.
D D
B2303 W8X18
18'-7
V.I.F

BR2305 L3X3X 1/4

C2303 HSS4X4X 3/8


1
1'-45/16 6'-11/4
EX.BEAM

EX.BEAM

EX.BEAM

EX.BEAM
EX.BEAM
EX.BEAM

E
E2306 SIM.

EX.BEAM
E
MATCH LINE

SEE E2303
PROJECT NORTH ENLARGED MEDICAL CEILING COLUMN FRAMING PLAN
REF.DWG.# 2/S102

REV. DATE DESCRIPTION BY CHK


B 06/01/2023 ISSUED FOR RE APPROVAL RMK SKG
APPROVER NOTE: A 04/26/2023 ISSUED FOR APPROVAL RMK SKG

1 PLEASE VERIFY AND CONFIRM THE CLOUDED MEDICAL COLUMN LOCATING PROJECT:

DIMENSION THAT WE FOLLOWED IS ACCEPTABLE.


ASPCA QUEENS CVC
2 PLEASE VERIFY THE CLOUDED EXISTING BEAM LOCATING DIMENSION . VIF 36-02 14TH STREET QUEENS, NY 11106
CONTRACTOR: DESIGNER/OWNER:

- -
FABRICATOR: MAT. SPEC.: HOLES:
N.A. N.A.
H&L IRON WORKS PAINT: WELDING:
N.A. N.A.
11-25 BROADWAY ASTORIA
DRAWN BY: DATE DRWN:
718-204-1298 RMK 05/26/2023
DESCRIPTION: JOB No.
CHCKD BY: DATE CHKD:
- PRIOR TO FABRICATION, DRAWINGS SHOULD BE ENLARGED MEDICAL CEILING COLUMN PLAN - SKG 06/02/2023
APPROVED BY ARCHITECT OR PROFESSIONAL DRG No.
ENGINEER.
- VERIFY ALL DIMENSIONS WITH ARCHITECT OR
SCE DETAILING GROUP INC.
PROFESSIONAL ENGINEER. 2165 5th Avenue Ronkonkoma, NY 11779 E2302
SCE JOB NO.: - TEL.#(718)-502-9461 FAX#(718)-502-9462
1 2 3

SEE E2302
20'-83/8 23'-6
V.I.F V.I.F
2
7'-55/8 7'-55/8 7'-55/8 7'-55/8 7'-55/8 7'-55/8 7'-31/8

MATCH LINE

F
EX.BEAM

5'-55/8 2'-0

EX.BEAM
4'-13/8
E2304 (TYP.)
B2302 W8X18
B 1 1
BR2301 L3X3X 1/4 1'-45/16
C2302 HSS4X4X 3/8
22'-1
V.I.F

1
E2304 (TYP)

P2303 PL1/2"X11 B
A A C2306 HSS4X4X 3/8
4'-6

E2304 E2304 B2306 W8X18

BR2305 L3X3X 1/4


C C
BR2307 L3X3X 1/4

4'-7
E2306 E2306
B2302 W8X18 C2301 HSS4X4X 3/8 1
BR2307 L3X3X 1/4
P2303 PL1/2"X11 B B2306 W8X18
5'-85/8

E2304
EX.BEAM
EX.BEAM

EX.BEAM

EX.BEAM
EX.BEAM
2'-107/8
A A BR2305 L3X3X 1/4
E2304 E2304
C C
E2306 C2305 HSS4X4X 3/8 E2306

G
B
E2304 (TYP)
5'-71/2

BR2301 L3X3X 1/4

6'-111/8
P2303 PL1/2"X11

B2302 W8X18 C2302 HSS4X4X 3/8

C2306 HSS4X4X 3/8

B2306 W8X18
A A
BR2307 L3X3X1/4
16'-0

4'-6
V.I.F

E2304 E2304 C BR2305 L3X3X 1/4 C 3


BR2301 L3X3X 1/4 E2306 E2306

4'-7
C2301 HSS4X4X 3/8
BR2307 L3X3X 1/4

B2306 W8X18
A B2302 W8X18 A
E2304 E2304
P2303 PL1/2"X11 BR2305 L3X3X 1/4
C C
4'-57/8
EX.BEAM

EX.BEAM
EX.BEAM
EX.BEAM

EX.BEAM

E2306 C2305 HSS4X4X 3/8 E2306 EX.BEAM

1 APPROVER NOTE:
P2303 PL1/2"X11
H B2306 W8X18 1 1 PLEASE VERIFY AND CONFIRM THE CLOUDED MEDICAL COLUMN LOCATING
2'-75/8

B2302 W8X18
DIMENSION THAT WE FOLLOWED IS ACCEPTABLE.
3'-91/8

C2306 HSS4X4X 3/8


C2302 HSS4X4X 3/8 2 PLEASE VERIFY THE CLOUDED EXISTING BEAM LOCATING DIMENSION . VIF
BR2301 L3X3X 1/4
BR2307 L3X3X1/4

BR2302 L3X3X 1/4


BR2305 L3X3X 1/4
3 MEDICAL CEILING BEAM WILL CLASH ON NEW RTU FRAMING,PLEASE CONFIRM MOVING W8X18
C C GOING SOUTH TO AVOID CLASHING IS CORRECT, OTHERWISE PLEASE FURNISH DIMENSION FOR NEW
BEAM/POST BELOW.
4'-7

E2306 E2306
A A BR2307 L3X3X 1/4
BR2302 L3X3X 1/4
4'-6

E2304 E2304
13'-0
V.I.F

B2306 W8X18
C2301 HSS4X4X 3/8
BR2305 L3X3X 1/4
C C
BR2301 L3X3X 1/4 C2305 HSS4X4X 3/8
E2306 E2306
A A
EX.BEAM
EX.BEAM

EX.BEAM
EX.BEAM
EX.BEAM

B2302 W8X18
EX.BEAM

E2304 E2304
REV. DATE DESCRIPTION BY CHK
P2303 PL1/2"X11 B 06/01/2023 ISSUED FOR RE APPROVAL RMK SKG
A 04/26/2023 ISSUED FOR APPROVAL RMK SKG

I PROJECT:

ASPCA QUEENS CVC


36-02 14TH STREET QUEENS, NY 11106
CONTRACTOR: DESIGNER/OWNER:

- -
FABRICATOR: MAT. SPEC.: HOLES:

H&L IRON WORKS


N.A. N.A.
PROJECT NORTH ENLARGED MEDICALCEILING COLUMN FRAMING PLAN PAINT:
N.A.
WELDING:
N.A.
11-25 BROADWAY ASTORIA
718-204-1298 DRAWN BY: DATE DRWN:
RMK 05/26/2023
DESCRIPTION: JOB No.
CHCKD BY: DATE CHKD:
- PRIOR TO FABRICATION, DRAWINGS SHOULD BE ENLARGED MEDICAL CEILING COLUMN PLAN - SKG 06/02/2023
APPROVED BY ARCHITECT OR PROFESSIONAL DRG No.
ENGINEER.
- VERIFY ALL DIMENSIONS WITH ARCHITECT OR
SCE DETAILING GROUP INC.
PROFESSIONAL ENGINEER. 2165 5th Avenue Ronkonkoma, NY 11779 E2303
SCE JOB NO.: - TEL.#(718)-502-9461 FAX#(718)-502-9462
SEE PLAN

DET. 2
4
1'-0 WALL PLATE PL1/2"X11 X 0'-11
EX.BEAM
PLATE PL3/8"X4 X 0'-6
WP BEAM ANGLE L4X3-1/2X3/8
W8X18
BEAM W8X18
BEAM W8X18

1/2

2
DET. 1 4
TYP 4
1/4

TYP PLATE PL1/4"X4 X 0'-10 1/2 1/2

6
3/16
W(1) 1/2Ø A307 1'-4 Shop weld
ERECTION BOLT
(TYP.) (U.N.O.) 2
WP WP 11/2 61/2 61/2 11/2
2

11/2
3/
1 4

BR
4

COLUMN HSS4X4X 3/8


AC
4
1 3/

EA
3 /4 4

NG
1

61/2
TYP

LE
1 1/4

L3

1'-4
VIF
X3
2'-3 2'-3

8'-01/8
12

X
1 /4

7'-9

61/2
613/16 VIF
1-1/2"Ø A325N_BOLT

8'-01/8
1
Post and plate only -
everything else by

BR
COLUMN HSS4X4X 3/8

/4
X1
others

11/2
AC
X3

COLUMN HSS4X4X 3/8


E
L3

AN
E
GL

GL
SECTION 3a -3a

AN

E
4

L3
E
Cloud elevation with PLATE PL1/4"X4 X 0'-10

AC

X3
note that approver W(1) 1/2Ø A307

X
BR

12

1 /4
1/2

12
EX.CMU WALL MUST confirm BO ERECTION BOLT
Plate elevation (TYP.) (U.N.O.) NUT 3/4_HEAVY_HEX_NUT
711/16 4 (TYP) COLUMN HSS4X4X 3/8
WP Cloud elevation with note 711/16
4 that approver MUST confirm WASHER 3/4_WASHER
BO Plate elevation
EL.+10'-77/8 1/2 WP TYP
(TYP)
B.O.P 3/16
6

3a 3a
WP
EL.+10'-77/8 BASE_PLATE
9

1/2
BASE_PLATE PL3/4"X16 X 1'-4 4 PL3/4"X16 X 1'-4
B.O.P

6
BASE_PLATE
PL3/4"X16 X 1'-4

9
4 BASE_PLATE
THREADED_ROD

9
PL3/4"X16 X 1'-4 4
RB3/4
DET. 3

CEILING V.I.F
CEILING V.I.F SECTION B - B
SECTION A - A E2303
E2303

CEILING V.I.F
DETAIL 3
VIF 2a (TYP.)BASEPLATE CONNECTION SET-UP

1/2 GAP 11
GAP 1/2
21/2 11/2 4 4 11/2
BEAM W8X18
1

21/2

11/2

APPROVER NOTE:
31/2

1 PLEASE CONFIM THE CLOUDED DIMENSION.


3

PLATE 2 PLEASE CONFIRM THE NUMBER OF HOLES AND BOLT SPACING DIMENSION.
11

EX.CMU WALL
8

3/8" shear
tab per RFI PL3/8"X4 X 0'-6
W(2) 3/4Ø A325 BOLTS 3 PLEASE CONFIRM USING ANGLE IN LIEU OF SHEAR TAB CONNECTION IS ACCEPTABLE
3 BEAM W8X18 WALL PLATE 4 PLEASE CONFIRM BRACE WORKING POINT DIMENSION IS CORRECT OTHERWISE PLEASE ADVISE
PLATE PL1/2"X11 X 0'-11
11/2

ANGLE L4X3- 1/2X3/8 W(4) 3/4"Ø HAS-E RODS


PL3/8"X4 X 0'-6
W(2) 3/4Ø A325N BOLTS EX.BEAM W(2) 3/4Ø A325 BOLTS 6 3/4" EMBEDMENT WIH HY270

WALL PLATE BEAM W8X18


3 SIDES TYP
1/4 PL1/2"X11 X 0'-11
1/4 W(4) 3/4"Ø HAS-E RODS
6 3/4" EMBEDMENT WIH HY270 SECTION 2a - 2a
DETAIL 1 DETAIL 2
(TYP.)NEW BEAM TO EXIST BEAM CONNECTION (TYP.)NEW BEAM TO EXIST WALL CONNECTION

2a REV. DATE DESCRIPTION BY CHK


B 06/01/2023 ISSUED FOR RE APPROVAL RMK SKG
A 04/26/2023 ISSUED FOR APPROVAL RMK SKG
Field verified as
existing C7x9.8. Refer PROJECT:
to RFI 06 and
response sketch
SKS-009 for revised
ASPCA QUEENS CVC
36-02 14TH STREET QUEENS, NY 11106
connection CONTRACTOR: DESIGNER/OWNER:

- -
FABRICATOR: MAT. SPEC.: HOLES:

H&L IRON WORKS


N.A. N.A.
PAINT: WELDING:
N.A. N.A.
11-25 BROADWAY ASTORIA
718-204-1298 DRAWN BY: DATE DRWN:
RMK 05/26/2023
DESCRIPTION: JOB No.
CHCKD BY: DATE CHKD:
- PRIOR TO FABRICATION, DRAWINGS SHOULD BE SECTIONS - SKG 06/02/2023
APPROVED BY ARCHITECT OR PROFESSIONAL DRG No.
ENGINEER.
- VERIFY ALL DIMENSIONS WITH ARCHITECT OR
SCE DETAILING GROUP INC.
PROFESSIONAL ENGINEER. 2165 5th Avenue Ronkonkoma, NY 11779 E2304
SCE JOB NO.: - TEL.#(718)-502-9461 FAX#(718)-502-9462
SEE PLAN

SEE PLAN ANGLE L4X3-1/2X3/8 SEE PLAN


1'-0 4'-0
1'-4
EX.BEAM EX.BEAM ANGLE L4X3-1/2X3/8 EX.BEAM
1'-45/16 1'-0 3
EX.BEAM WP
ANGLE L4X3-1/2X3/8 BEAM W8X18 BEAM W8X18 BEAM W8X18
WP 3
BEAM W8X18

WP

1/2
ANGLE L4X3- 1/2X3/8

1/2

1/2
2

2
2
PLATE PL1/4"X4 X 0'-10 TYP.
TYP 2 1/4 TYP. 2
1/4 TYP. W(1) 1/2Ø A307 1/4
PLATE PL1/4"X4 X 0'-10 3/16 PLATE PL1/4"X4 X 0'-10
ERRECTION BOLTS
W(1) 1/2Ø A307 W(1) 1/2Ø A307
ERRECTION BOLTS ERECTION BOLTS
13/4
TYP TYP.
3/16
3/16

1 3/
COLUMN HSS4X4X 3/8
4

BR

/4
3X 1
AC
/4
X1

EA
X3

X
L3
L3

NG

E
1

LE
VIF

GL
LE
12
G

12
AN
AN
VIF

L3
VIF

8'-01/8
COLUMN HSS4X4X 3/8

E
X3
CE

COLUMN HSS4X4X 3/8


713/16

8'-01/8
7'-9
8'-01/8

AC
1

X
63/8
A

1 /4

BR
7'-9

BR

12
1 1 3/
4
65/16

4 Cloud elevation
Cloud elevation with 2 4 with note that
4 approver MUST
Cloud elevation with note that approver 2 confirm BO Plate
note that approver MUST confirm BO PLATE PL1/4"X4 X 0'-10 elevation
MUST confirm BO 2 Plate elevation W(1) 1/2Ø A307 PLATE PL1/4"X4 X 0'-10
Plate elevation PLATE PL1/4"X4 X 0'-10 ERECTION BOLTS W(1) 1/2Ø A307
W(1) 1/2Ø A307 WP 3 ERECTION BOLTS
ERECTION BOLTS
3 WP

1'-2
3 WP EL.+10'-77/8 1/2

1'-2
EL.+10'-77/8
1'-0

B.O.P

6
EL.+10'-77/8 1/2 1/2
B.O.P
6

6
B.O.P

9
DET. 3 BASE_PLATE
9

9
PL3/4"X16 X 1'-4 BASE_PLATE
E2304
PL3/4"X16 X 1'-4
DET. 3
BASE_PLATE E2304
PL3/4"X16 X 1'-4 DET. 3
CEILING V.I.F E2304
CEILING V.I.F
SECTION C - C SECTION D - D CEILING V.I.F
E2303 E2302
SECTION E-E
E2302

APPROVER NOTE:

1 PLEASE CONFIRM THE CLOUDED DIMENSION.

2 PLEASE CONFIRM PLATE SIZE IS CORRECT OTHERWISE PLEASE ADVISE

3 PLEASE COMFIRM BRACE WORKING POINT DIMENSION IS CORRECT,


OTHERWISE PLEASE ADVISE

REV. DATE DESCRIPTION BY CHK


A 06/01/2023 ISSUED FOR APPROVAL RMK SKG

PROJECT:

ASPCA QUEENS CVC


36-02 14TH STREET QUEENS, NY 11106
CONTRACTOR: DESIGNER/OWNER:

- -
FABRICATOR: MAT. SPEC.: HOLES:

H&L IRON WORKS


N.A. N.A.
PAINT: WELDING:
N.A. N.A.
11-25 BROADWAY ASTORIA
718-204-1298 DRAWN BY: DATE DRWN:
RMK 05/26/2023
DESCRIPTION: JOB No.
CHCKD BY: DATE CHKD:
- PRIOR TO FABRICATION, DRAWINGS SHOULD BE SECTIONS - SKG 06/02/2023
APPROVED BY ARCHITECT OR PROFESSIONAL DRG No.
ENGINEER.
- VERIFY ALL DIMENSIONS WITH ARCHITECT OR
SCE DETAILING GROUP INC.
PROFESSIONAL ENGINEER. 2165 5th Avenue Ronkonkoma, NY 11779 E2306
SCE JOB NO.: - TEL.#(718)-502-9461 FAX#(718)-502-9462

You might also like