Compressive Strength Test Report

This test report summarizes testing of a Thermoblock sample received from Decomix. The sample was tested for compressive strength according to BS EN 772-1:2011+A1:2015. The test result was 12.07 N/mm2 with an uncertainty of ±0.63 N/mm2. Testing was conducted at Marmox Egypt Lab on May 29, 2023 under laboratory conditions of 23.9°C and 51% humidity.

Uploaded by

Mohamed Gaballah
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

Compressive Strength Test Report

This test report summarizes testing of a Thermoblock sample received from Decomix. The sample was tested for compressive strength according to BS EN 772-1:2011+A1:2015. The test result was 12.07 N/mm2 with an uncertainty of ±0.63 N/mm2. Testing was conducted at Marmox Egypt Lab on May 29, 2023 under laboratory conditions of 23.9°C and 51% humidity.

Uploaded by

Mohamed Gaballah
Copyright
© © All Rights Reserved
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

Testing CAB # 022254

Test Report No.: 16/2023


 Customer Details:
Name: Decomix
Address: 4th industrial area / Sadat city
Contact information: +201002161302
 Sample Description: Thermoblock (600 x 140 x 54)
 Sample Identification:
 Sample Receiving date: 27/5/2023
 Test and reporting date: 29/5/2023
_____________________________________________________________________________________________________________________________
TEST RESULT

Number
Uncertainty Unit Result of Test Standard Test Type
specimens

±0.63 N/mm² N/mm² 12.07 6 BS EN 772-1:2011+A1:2015 Compressive strength

 Lab Condition :
Temperature Deg.C. 23.9 °C Humidity: 51 %
____________________________________________________________________________________________________________________

Tested By : Name / Title Approved By : Name / Title

Signature : Signature :

This report is applied to the sample as received & was released in accordance with the requirements
of accreditation bodies and it was investigation connectivity measurements to national as well as
references with all the units of measurement used in international laboratories.
This report will not be reissued again only through a written certification from the Department of the
lab.
Expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k =2,
providing a level of confidence of approximately 95%.

___________________________________________________________________________________________________________________________________
Laboratory: Marmox Egypt Lab

Address: Industrial zone of Wadi El Natroun City, on the Km 104 Cairo-Alexandria desert road
Head Office: 43 El Haram St., Giza, Egypt
Tel.: 01282108768 Email: [email protected]

F7.08-01/01 Page No. 1 of 1