0% found this document useful (0 votes)
194 views2 pages

480TBnexans Katalog en 1 2019

Uploaded by

Lucas Tavares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
194 views2 pages

480TBnexans Katalog en 1 2019

Uploaded by

Lucas Tavares
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

480TB/G

EUROMOLD® Compact tee connector


for multiple voltage levels
Interface C
up to 42 kV, 630 A/1250 A1)

Application Technical characteristics U0 / U (Um )


Suitable for installation on • The thick conductive EPDM jacket 6/10 (12) kV
polymeric insulated medium provides a total safe to touch screen 6.35/11 (12) kV
voltage cables with extruded to ensure safety. 8.7/15 (17.5) kV
easy strip conductive screen or • Metal housing available on request.
12/20 (24) kV
bonded extruded conductive • For use with test rod 800TR/800TR-A.
screen. For use with other cable • Each separable connector is tested
12.7/22 (24) kV
types please contact our sales for AC withstand and partial
18/30 (36) kV
representative. discharge prior to leaving the factory. 19/33 (36) kV
20.8/36 (42) kV

Design 185 mm
1. Conductive EPDM insert
2. Conductive EPDM jacket
3. Insulating EPDM layer
4. Type C1+C2 interface as Dia. 80
described by CENELEC
EN 50180 and 50181
5. Bolted or crimp conductor contact
6. Basic insulating plug 4 9
(with voltage detection point,
standard from 30 kV) 8
5
7. Cable reducer
8. Conductive rubber cap 1 6
9. Clamping screw 430 TCS
(optional M16 stud with spring 290 mm 2
washer and nut) Dia. 652)
10. Earth lead 3

The screen break design enables


cable outer sheath testing without 10
removing or dismantling the
connector.

7
Specifications and
standards
The 480TB/G separable connector
meets the requirements of 2)
The indicated diameter is a die dimension. Depending on the conductor
CENELEC HD 629.1. ATEX version cross-section used, a deviation of up to +5 mm is possible.
can be delivered on request.

Separable connector Nominal voltage Current Conductor cross-section (mm2)


type U0 /U (kV) In (A) min. max.
480TB/G 6/10 630/12501) 25 300
15-01-2019

K480TB/G 12/20 630/12501) 35 300


M480TB/G 18/30 630/12501) 50 300
P480TB/G 20.8/36 630/12501) 50 240
1)
When installed on appropriate equipment bushing.

18
The kit also comprises:
Kit contents + installation instructions
The complete (K)(M)(P)480TB/G tee connector + silicone grease
kit comprises 3 x the following components: + wipers
+ screen wire cable lugs
Standard delivery
= range
Clamping
Conductor contact
screw
TMBC For application
430TCS
+ + + + with a compression
conductor connec-
tor, the cable data,
including the shape,
Basic insulating = cross-section and
M16 stud plug Connector housing Cable reducer Conductor contact material of the
with spring + rubber cap (K)(M)(P)480BT/G 430CA TBC conductor, must
washer and (K)800BIPR/ be indicated when
nut (M)(P)800BIPA ordering.

Ordering instructions Multirange assignment


Indicate the part number for Cross- Dia. over core
Ordering part number for (K)(M)(P)480TB/G
multirange application when section insulation (mm)
with mechanical connector TMBC
ordering (see table). (mm2)
min. max. with clamping screw 430TCS / with M16 stud
Nominal voltage U0 /U 6/10 kV
Order example:
25 13.0 15.2
1 compact tee connector kit 35 14.1 16.3
501125/
for 12/20 kV, for 95-300 mm² 501126
50 15.3 17.5
with mechanical conductor 70 17.0 19.2
95 17.9 20.8 501127/
connector and clamping screw 120 19.4 22.8 501128
430 TCS. Order according to the 150 20.9 24.3
table: 1 kit – K480TB/G with 185 22.5 25.9
501129/
240 25.0 28.4
part number 501133. 300 27.7 30.4 501130
Nominal voltage U0 /U 12/20 kV (K)
Note: The classification does 35 18.3 20.5
only apply for polymeric insulated 501131/
50 19.5 21.7
501132
XLPE cables (dimensions acc. 70 21.2 23.4
95 22.8 25.0
to DIN VDE 0276 620) with 120 23.6 27.0
extruded conductive screen and 150 25.1 28.5 501133/
stranded conductors. 185 26.7 30.1 501134
3) 240 29.2 32.6 501135/
Since the dimensions for 300 31.2 34.6 501136
cables at voltage level 20.8/36 Nominal voltage U0 /U 18/30 kV (M)
(42) kV are not yet standardised,
50 23.8 26.7
the conductor cross-sections and 70 25.5 28.4 501137/
their assignment of diameters 95 27.1 30.0 501138
over core insulation given in 120 28.6 32.0
150 30.1 33.5
the table are to be considered 185 31.7 35.1 501139/
approximate values. When 240 34.2 37.6 501140 501141/
ordering accessories, we would 300 36.9 39.6 501142
like to ask you to indicate the Nominal voltage U0 /U 20.8/36 kV3) (P)
checked diameters over core 50 23.8 26.7
70 25.5 28.4 501143/
insulation. 501144
95 27.1 30.0
120 28.6 32.0
150 30.1 33.5
185 31.7 35.1 501145/
240 34.2 37.6 501146

For use with For use with For outdoor If an ATEX certification for All accessories available When installed on
15-01-2019

copper tape other cable types applications. connectors up to 12 kV is with mechanical or appropriate equipment
screened cables. please contact our required, contact our sales repre- compression conductor bushing: 1250 A
Order: Kit MT. representative. sentative before ordering. connector. continuously.

Nexans Power Accessories Germany GmbH • Ferdinand-Porsche-Str. 12 • 95028 Hof/Saale • Phone: +49 9281 8306-0
[email protected] • www.nexans-power-accessories.com

19