SMSV 2020

The document provides a matrix summarizing DOE evaporator compliance for large evaporators in SM/SV Series unit coolers from DOE/NRCan. Key features include: 1) Dual speed and variable speed motors are available depending on the model and refrigerant type. 2) Various voltages and phases are supported between 115/1 to 460/3. 3) Fan controls include options like thermostats, relays, amplifiers depending on the remote controller and board. 4) Defrost types and sensors vary based on whether the cooler uses glide or non-glide refrigerants, and if it uses air or positive defrost. 5) Expansion

Uploaded by

Marcos Rocha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views

SMSV 2020

The document provides a matrix summarizing DOE evaporator compliance for large evaporators in SM/SV Series unit coolers from DOE/NRCan. Key features include: 1) Dual speed and variable speed motors are available depending on the model and refrigerant type. 2) Various voltages and phases are supported between 115/1 to 460/3. 3) Fan controls include options like thermostats, relays, amplifiers depending on the remote controller and board. 4) Defrost types and sensors vary based on whether the cooler uses glide or non-glide refrigerants, and if it uses air or positive defrost. 5) Expansion

Uploaded by

Marcos Rocha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

DOE / NRCan Model Information Inside

SM/SV Series
PRODUCT COOLERS

Technical Bulletin: SMSV_012_121820

Products that provide lasting solutions.


SM/SV Series Unit Coolers

DOE Evaporator Compliant Matrix


DOE Evaporator Summary Matrix for Large Evaporators

SM / SV
DUAL SPEED VARIABLE SPEED
DEFROST TYPE
MOTORS MOTORS
AIR
X (Except SM*14A, SM*24A,
SM*26A-0746, SM*27A-0811,
SM*34A-1123 and 1243,
Glide Refrigerants* SM*36A-1289, SM*37A-1402, X
SM*44A-1532 and 1829,
SM*46A-1846)

Non-Glide Refrigerants** X

ELECTRIC
Glide Refrigerants *

X (Except SM*14E-0384,
Coolers SM*24E-0759, SM*34E-1070, X
SM*36E-1225, SM*46E-1754)
Freezers X (Except ALL SV Models) X
Non-Glide Refrigerants **
Coolers - X
Freezers - X
HOT GAS
Glide Refrigerants * X - Available
X (Except SM*14( )-0384, * Glide Refrigerants (R-407A, R-407F, R-448A, R-449A,
Coolers SM*24( )-0759,SM*34( )-1070, X refer to I/O Manual for Others). Models in tables
SM*36( )-1225, SM*46( )-1754)
with ‘*’ are not tied to this note.
Freezers X X
** Non-Glide Refrigerants (R-404A, R-507A,
Non-Glide Refrigerants ** refer to I/O Manual for Others)
Coolers - X
*** Room T-Stat Needs to be Separate from
Freezers - X
T-Stat Controlling Motors
VOLTAGES / PHASE (All 60 HZ)
115/1 - -
**** Includes 10 V Power Supply for Driving Fans
to Low Speed
208-230/1 - -
208-230/3 X X
***** Amplier Works with a Maximum of Six Motors
460/1 - -
1
460/3 X X Only One Control May Be Selected
575/3 - - 2
Only on Muitiple Fan Units Wired for Three Phase Operation
FAN CONTROLS
3
RT-3*** - T-Stat - - Choose Only One Type of Expansion Valve
RT-4*** - T-Stat with 0 to 10 V Power Supply X
1 - 4
Choose Only One Based Upon Either Air
R24V - Relay If Remote Board - -
or Positive Defrost Requirements
R24P**** - Relay If Remote Board X
1 -
5
VC4P - JC450 Plus Amplifier - - More Than One Option Can Be Chosen
AMP1***** - Amplifier for Remote Controller - -
VC4 - JC450 Loose - X
1

VC4A, VC4B - JC450 Mounted with Transformer - X1


KE2 Therm - X1
Expansion Valves
TEV - X
3

Sporlan Stepper Valve - X3


Control Boards DOE / NRCan -
KE2 OEM Board - X
Sensors
The SM series of evaporators are
Air Defrost - Two Temp Sensors (1 Room, 1 Coil) - 4
designed for long life with testing
X
Positive Defrost - 3 Temp Sensors (1 Room, 2 Coils) - and options to meet efficiency
X4
Options required by DOE and NRCan
Remote Display (Stays within Six Feet of Board) - regulations. SV models have longer
X5
Edge Manager (for Remote WiFi Access and Data Logging) - air throw for application in larger non-
X5
8 or 16 Port Switch (Inter-Connecting Multiple Boards) - X5
regulated freezer applications.

* Glide Refrigerants (R-407A, R-407F, R-448A, R-449A, refer to I/O Manual for Others). 1 Only One Control May Be Selected
Models in tables with '*' are not `ed to this note. 2 Only on Mui`ple Fan Units Wired for Three Phase Operaton
3 Choose Only One Type of Expansion Valve
1 SM/SV
** Non-Glide RefrigerantsSERIES UNIT
(R-404A, R-507A, refer toCOOLERS
I/O Manual for Others)
*** Room T-Stat Needs to be Separate from T-Stat Controlling Motors 4 Choose Only One Based Upon Either Air or Posi`ve Defrost Requirements
**** Includes 10 V Power Supply for Driving Fans to Low Speed 5 More Than One Op`on Can Be Chosen
Specifications subject to change without
***** Ampliier Works with a Maximum of Six Motors
notice.
SM/SV Series Unit Coolers
Photo on front cover shown
with optional Long Throw Standard Features
Air Boosters

SM SERIES – SV SERIES –
Ideal for Warehouse Coolers or Freezer Designed to Deliver Low Temperature Air
with a Wide Range of Capacities at High Velocity in Freezers
n R
 uggedly constructed cabinets are installed pulled n R
 uggedly constructed cabinets are installed pulled
against the ceiling or with hanger rods sloped towards against the ceiling or with hanger rods sloped towards
the drain connection on the end of the unit. the drain connection on the end of the unit.
n E
 fficient draw-thru design with 30" diameter aluminum n E
 fficient draw-thru design with 30" diameter aluminum
fan blades provide air throw of 60 feet. fan blades provide air throw of 80 feet.
n H
 igh efficiency 1 horsepower 3 phase motors operate n H
 igh efficiency 1-1/2 horsepower 3 phase motors
fans at 850 RPM. operating fans at 1140 RPM.
n W
 ide capacity range with coils with 4, 5, 6, or 7 fins n W
 ide capacity range with coils with 4, 5, or 6 fins
per inch. per inch.
n Air defrost models for rooms operating above 34° F. n E
 lectric and hot gas defrost models for low
temperature rooms.
n E
 lectric and hot gas defrost models for colder rooms
and freezers. n M
 ill galvanized drain pan and fan cabinet.
n Mill galvanized drain pan and fan cabinet. n C
 oated, corrosion-resistant wire fan guards.
n Coated, corrosion-resistant wire fan guards. n Insulated drain pan on electric and gas defrost models.
n Insulated drain pan on electric and gas defrost models. n D
 rain pan and fan cabinet end panels are hinged for
easy access and cleaning.
n D
 rain pan and fan cabinet end panels are hinged for
easy access and cleaning. n F
 actory-wired fans and defrost controls to convenient
terminal strips for field connections.
n F
 actory-wired fans and defrost controls to convenient
terminal strips for field connections. n A
 djustable defrost termination and fan delay
thermostat installed with electric defrost.
n A
 djustable defrost termination and fan delay
thermostat installed with electric defrost. n C
 oil constructed of heavy-wall copper tube and
rippled full collar aluminum fins.
n C
 oil constructed of heavy-wall copper tube and
rippled full collar aluminum fins. n O
 ptimized circuiting for HFC and HFO refrigerants.
n Optimized circuiting for HFC and HFO refrigerants. n S
 ealed and pressurized from the factory.
n Sealed and pressurized from the factory.
Optional Features and Accessories
Optional Features and Accessories n V
 ariable Speed EC with brushless permanent magnet
motor and panel mounted electronic drive.
n V
 ariable Speed EC with brushless permanent magnet
motor and panel mounted electronic drive. n Installed thermostat and controller options for simple
Dual Speed or Variable Speed EC fan control.
n Installed thermostat and controller options for simple
Dual Speed or Variable Speed EC fan control. n H
 ot gas defrost models available with gas or electric
pan heat.
n H
 ot gas defrost models available with gas or electric
pan heat. n Installed mechanical or electronic expansion valves.
n C
 oils circuited for fluids operating as a secondary n L
 iquid line solenoid valve installed or ship loose.
coolant.
n P
 ainted white or black housing and drain pans.
n Installed mechanical or electronic expansion valves.
n S
 tainless-steel housing and drain pans in place of
n Liquid line solenoid valve installed or ship loose. galvanized steel.
n Painted white or black housing and drain pans. n C
 opper fins or coil coating from Electrofin or Heresite.
n S
 tainless-steel housing and drain pans in place of n L
 ong throw adapters increase air throw to 120 feet.
galvanized steel.
n Insulated drain pan on air defrost models.
n Copper fins or coil coating from Electrofin or Heresite.
n Long throw adapters increase air throw to 100 feet.

SM/SV SERIES UNIT COOLERS 2


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Ordering Information
Specify When Ordering All Models
n Complete model number including refrigerant n Liquid refrigerant temperature
n Room temperature n Optional features
n Evaporating temperature n Optional accessories

Model Key
SM A 2 5 E - 0842 T C K K
SM A 2 5 E - 0842 T C K K
Unit Type Heater Voltage
Unit
SM TypeMaster
- Space K Heater Voltage
- 208-230/3/60
SV SM
- High Velocity
- Space Master M -K460/3/60
- 208-230/3/60
P -M575/3/60
DOESV - High Velocity
Application - 460/3/60
U -P380/3/50
- 575/3/60
DDOE
- DOEApplication
and NRCan L -U380/3/60*
- 380/3/50
A -DNon-Regulated
- DOE and NRCan L - 380/3/60*
Motor Voltage
A - Non-Regulated
Number of Fans K Motor Voltage
- 208-230/3/60
Number of Fans M -K460/3/60
- 208-230/3/60
Fin Spacing P -M575/3/60
- 460/3/60
U -P380/3/50
4,Fin Spacing
5, 6, 7 FPI - 575/3/60
L -U380/3/60*
- 380/3/50
Type4,of5,Defrost
6, 7 FPI
L - 380/3/60*
Motor Type***
AType of Defrost
- Air Defrost
E - AElectric Defrost w/Electric Pan Heat C Motor Type***
- 3 Phase Motors**
- Air Defrost V - CVariable Speed EC, 3 Phase
G -E3-Pipe Hot Gas w/Gas
Electric Defrost Pan Heat
w/Electric Pan Heat - 3 Phase Motors**
H -G3 -Pipe HotHot
GasGas
w/Electric Pan Heat
Heat D -VVariable Speed EC,EC,
- Variable Speed 2 Speed Control
3 Phase
3 Pipe w/Gas Pan
K - H2 -Pipe Kool Gas w/Gas Pan Heat
3 Pipe Hot Gas w/Electric Pan Heat D - Variable Speed EC, 2 Speed Control
Refrigerant
P - K2 -Pipe Kool
2 Pipe GasGas
Kool w/Electric Pan Heat
w/Gas Pan Heat
R - PHeat Reclaim
- 2 Pipe Kool Gas w/Electric Pan Heat NRefrigerant
- Stock Unit**** G - Stock Unit*****
R - Heat Reclaim S -N R-404A
- Stock Unit**** Q -GR-407A T - R-448A
- Stock Unit*****
P - SR-507A
- R-404A F - R-407F
Q - R-407AR - TR-449A
- R-448A
B - PGlycol
- R-507A
/ Brine F - R-407F R - R-449A
UL C UL BTU/H inBHundreds
- Glycol / (00)
Brine
BTU/H in Hundreds (00)
* Contact application engineering for quoting.
** Invertor suitable motor for K, M, P, and U voltages with 3 phase motors.
* Contact application engineering for quoting.
*** Available in K, M, U, and L motor voltages. DOE and NRCan applications with Dual Speed or Variable Speed EC control.
** Invertor suitable motor for K, M, P, and U voltages with 3 phase motors.
N Stock
******* Units
Available areM,forU,non-glide
in K, or glide
and L motor refrigerants
voltages. DOE and(consult
NRCanI/O manual forwith
applications complete refrigerant
Dual Speed listing).Speed EC control.
or Variable
G Stock
********* Units are for glide refrigerants only (consult I/O manual for complete refrigerant listing).
N Stock Units are for non-glide or glide refrigerants (consult I/O manual for complete refrigerant listing).
***** G Stock Units are for glide refrigerants only (consult I/O manual for complete refrigerant listing).

DOE / NRCan -
Indicates evaporator models that have an AWEF rating published which meets the efficiency requirements of the US Department
of Energy and Natural Resources Canada regulations. These specific regulations are for evaporators manufactured after July 10th, 2020,
applied in refrigerated spaces 3000 square feet or less, and held at 55° F room temperature or colder. Not covered in this regulation
are unit coolers using secondary refrigerant like glycol.
Hussmann/Krack will ship DOE / NRCan compliant evaporator coil units for regulated/covered applications to meet and adhere with
government labeling requirements. Please note that compliance is at the time of manufacture and responsibility of the OEM.
The DOE / NRCan compliant evaporators will utilize Dual Speed or Variable Speed EC motors. Controls for these options may be
factory installed or field supplied.
Both the Dual Speed and Variable Speed EC motors have default prevention programming. In the event of a control loss input (0V),
the motors will run at full speed.
SM/SV Series Unit Coolers

Air Defrost High Profile

AIR DEFROST
Cooler AWEF by Refrigerant and Motor
[G] Stock Unit**, [N] Stock Unit***,
[Q] R-407A, [F] R-407F, [S] R-404A, REFRIGERATION
CAPACITY
[T] R-448A, [R] R-449A [P] R-507A CONNECTIONS DIMENSIONS (IN)
(BTU/H) AIR REF SHIP
{D}ual {V}ariable {D}ual {V}ariable @ 10° F TD FLOW CHARGE WGT
MODEL Speed Speed Speed Speed +25° F EVAP (CFM) LIQ SUCT (LBS) L W H (LBS)
SM*14A-0314[ ]{ } NA 9.00 NA 9.00 31,400 9,860 NA 1-3/8" 10 77.00 38.50 40.50 410
SM*16A-0378[ ]{ } 9.00 9.00 NA 9.00 37,800 8,980 NA 1-3/8" 10 77.00 38.50 40.50 445
SM*17A-0410[ ]{ } 9.00 9.00 NA 9.00 41,000 8,550 NA 1-3/8" 10 77.00 38.50 40.50 465
SM*14A-0403[ ]{ } NA 9.00 NA 9.00 40,300 9,690 NA 1-5/8" 13 77.00 38.50 40.50 430
SM*16A-0463[ ]{ } 9.00 9.00 NA 9.00 46,300 8,810 NA 1-5/8" 13 77.00 38.50 40.50 470
SM*17A-0503[ ]{ } 9.00 9.00 NA 9.00 50,300 8,390 NA 1-5/8" 13 77.00 38.50 40.50 490
SM*14A-0469[ ]{ } 9.00 9.00 NA 9.00 46,900 9,510 NA 1-5/8" 16 77.00 38.50 40.50 450
SM*16A-0538[ ]{ } 9.00 9.00 9.00 9.00 53,800 8,480 NA 1-5/8" 16 77.00 38.50 40.50 495
SM*17A-0585[ ]{ } 9.00 9.00 9.00 9.00 58,500 8,100 NA 1-5/8" 16 77.00 38.50 40.50 515
SM*14A-0526[ ]{ } 9.00 9.00 NA 9.00 52,600 9,330 NA 2-1/8" 19 77.00 38.50 40.50 484
SM*16A-0604[ ]{ } 9.00 9.00 9.00 9.00 60,400 8,400 NA 2-1/8" 19 77.00 38.50 40.50 530
SM*17A-0657[ ]{ } 9.00 9.00 9.00 9.00 65,700 8,000 NA 2-1/8" 19 77.00 38.50 40.50 550
SM*24A-0619[ ]{ } NA 9.00 NA 9.00 61,900 19,700 NA 2-1/8" 18 134.30 38.50 40.50 830
SM*26A-0746[ ]{ } NA 9.00 NA 9.00 74,600 17,900 NA 2-1/8" 18 134.30 38.50 40.50 885
SM*27A-0811[ ]{ } NA 9.00 NA 9.00 81,100 17,100 NA 2-1/8" 18 134.30 38.50 40.50 940
SM*24A-0797[ ]{ } NA 9.00 NA 9.00 79,700 19,380 NA 2-5/8" 24 134.30 38.50 40.50 836
SM*26A-0915[ ]{ } 9.00 9.00 NA 9.00 91,500 17,600 NA 2-5/8" 24 134.30 38.50 40.50 895
SM*27A-0995[ ]{ } 9.00 9.00 NA 9.00 99,500 16,800 NA 2-5/8" 24 134.30 38.50 40.50 950
SM*24A-0882[ ]{ } NA 9.00 NA 9.00 88,200 18,890 NA 2-5/8" 30 134.30 38.50 40.50 845
SM*26A-1063[ ]{ } 9.00 9.00 NA 9.00 106,300 16,900 NA 2-5/8" 30 134.30 38.50 40.50 905
SM*27A-1155[ ]{ } 9.00 9.00 NA 9.00 115,500 16,100 NA 2-5/8" 30 134.30 38.50 40.50 960
SM*24A-1038[ ]{ } 9.00 9.00 NA 9.00 103,800 18,400 NA 2-5/8" 36 134.30 38.50 40.50 858
SM*26A-1192[ ]{ } 9.00 9.00 NA 9.00 119,200 16,800 NA 2-5/8" 36 134.30 38.50 40.50 915
SM*27A-1296[ ]{ } 9.00 9.00 9.00 9.00 129,600 15,900 NA 2-5/8" 36 134.30 38.50 40.50 975
SM*34A-1123[ ]{ } NA 9.00 NA 9.00 112,300 28,600 NA 2-5/8" 33 134.30 38.50 51.00 960
SM*36A-1289[ ]{ } NA 9.00 NA 9.00 128,900 24,900 NA 2-5/8" 33 134.30 38.50 51.00 1,070
SM*37A-1402[ ]{ } NA 9.00 NA 9.00 140,200 24,700 NA 2-5/8" 33 134.30 38.50 51.00 1,090
SM*34A-1243[ ]{ } NA 9.00 NA 9.00 124,300 28,000 NA 2-5/8" 40 134.30 38.50 51.00 1,034
SM*36A-1498[ ]{ } 9.00 9.00 NA 9.00 149,800 24,600 NA 2-5/8" 40 134.30 38.50 51.00 1,156
SM*37A-1628[ ]{ } 9.00 9.00 NA 9.00 162,800 23,700 NA 2-5/8" 40 134.30 38.50 51.00 1,175
SM*34A-1463[ ]{ } 9.00 9.00 NA 9.00 146,300 27,400 NA 2-5/8" 48 134.30 38.50 51.00 1,100
SM*36A-1678[ ]{ } 9.00 9.00 NA 9.00 167,800 24,400 NA 2-5/8" 48 134.30 38.50 51.00 1,235
SM*37A-1824[ ]{ } 9.00 9.00 NA 9.00 182,400 23,500 NA 2-5/8" 48 134.30 38.50 51.00 1,255
SM*44A-1532[ ]{ } NA 9.00 NA 9.00 153,200 33,900 NA 2-5/8" 42 173.00 38.50 52.50 1,280
SM*46A-1846[ ]{ } NA 9.00 NA 9.00 184,600 33,200 NA 2-5/8" 42 173.00 38.50 52.50 1,430
SM*47A-1920[ ]{ } 9.00 9.00 NA 9.00 192,000 32,930 NA 2-5/8" 42 173.00 38.50 52.50 1,455
SM*44A-1829[ ]{ } NA 9.00 NA 9.00 182,900 33,400 NA 2-5/8" 52 173.00 38.50 52.50 1,380
SM*46A-2204[ ]{ } 9.00 9.00 NA 9.00 220,400 32,800 NA 2-5/8" 52 173.00 38.50 52.50 1,540
SM*47A-2281[ ]{ } 9.00 9.00 NA 9.00 228,100 31,600 NA 2-5/8" 52 173.00 38.50 52.50 1,565
SM*44A-2015[ ]{ } 9.00 9.00 NA 9.00 201,500 33,000 NA 2-5/8" 62 173.00 38.50 52.50 1,470
SM*46A-2428[ ]{ } 9.00 9.00 NA 9.00 242,800 32,530 NA 2-5/8" 62 173.00 38.50 52.50 1,645
SM*47A-2581[ ]{ } 9.00 9.00 9.00 9.00 258,100 31,330 NA 2-5/8" 62 173.00 38.50 52.50 1,670
* For motor code and refrigerant, use "D" when AWEF rating is shown and "A" for non-regulated applications or where AWEF is NA.
Include fan motor heat of 4000 BTU/H per fan for SM and 6600 BTU/H per fan for SV models in room load calculations. De-rate capacity 12% for 50 Hertz operation with 3 phase motors only.
[ ] Location for the refrigerant letter code. { } 3 phase motor C is standard for non-regulated applications, include "V" for Variable Speed EC control or "D" when Dual Speed control
of the variable speed motor will be from a fixed 10 V signal.
** G Stock Units are for glide refrigerants only (consult I/O manual for complete refrigerant listing).
*** N Stock Units are for non-glide or glide refrigerants (consult I/O manual for complete refrigerant listing).

EXAMPLE FULL MODEL:


SMA36A-1498TCK is non-regulated application with R-448A, three phase motors and 208/3/60 power.

Key Point -
Krack evaporator capacities shown are with midpoint evaporating temperature to offer a consistent capacity
for selection when using different refrigerants and match other Krack and Hussmann equipment.

Prices, product availability, and specifications


are subject to change without notice. Page 1 of 1
SM/SV SERIES UNIT COOLERS 4
Specifications subject to change without notice.
SM/SV Series Unit Coolers

Electric Defrost High Profile

MEDIUM TEMPERATURE
AWEF by Refrigerant, Motor, and Application
[G] Stock Unit**, [N] Stock Unit***,
[Q] R-407A, [F] R-407F, [S] R-404A,
[T] R-448A, [R] R-449A [P] R-507A
CAPACITY CAPACITY REFRIGERATION
{D}ual {V}ariable {D}ual {V}ariable CONNECTIONS DIMENSIONS (IN)
(BTU/H) (BTU/H) AIR REF SHIP
Speed Speed Speed Speed
@ 10° F TD @ 10° F TD FLOW CHARGE WGT
SM MODEL Freezer Cooler Freezer Cooler Freezer Cooler Freezer Cooler -20° F EVAP +20° F EVAP (CFM) LIQ SUCT (LBS) L W H (LBS)
SM*14E-0384[ ]{ } 4.15 NA 4.15 9.00 NA NA 4.15 9.00 38,400 40,300 9,690 NA 1-5/8" 13 77.00 38.50 40.50 440
SM*15E-0426[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 42,600 44,700 6,250 NA 1-5/8" 13 77.00 38.50 40.50 450
SM*16E-0440[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 44,400 46,300 8,810 NA 1-5/8" 13 77.00 38.50 40.50 470
SM*14E-0501[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 50,100 52,600 9,330 NA 2-1/8" 19 77.00 38.50 40.50 495
SM*15E-0556[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 55,600 58,400 8,900 NA 2-1/8" 19 77.00 38.50 40.50 505
SM*16E-0574[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 57,400 60,400 8,400 NA 2-1/8" 19 77.00 38.50 40.50 530
SM*24E-0759[ ]{ } 4.15 NA 4.15 9.00 NA NA 4.15 9.00 75,900 79,700 19,380 NA 2-1/8" 24 134.30 38.50 40.50 836
SM*25E-0842[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 84,200 88,400 18,500 NA 2-1/8" 24 134.30 38.50 40.50 874
SM*26E-0869[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 86,900 91,500 17,600 NA 2-1/8" 24 134.30 38.50 40.50 912
SM*24E-0989[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 98,900 103,800 18,400 NA 2-5/8" 36 134.30 38.50 40.50 860
SM*25E-1097[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 109,700 115,200 17,600 NA 2-5/8" 36 134.30 38.50 40.50 900
SM*26E-1132[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 113,200 119,200 16,800 NA 2-5/8" 36 134.30 38.50 40.50 920
SM*34E-1070[ ]{ } 4.15 NA 4.15 9.00 NA NA 4.15 9.00 107,000 112,300 28,600 NA 2-5/8" 33 134.30 38.50 51.00 1,030
SM*35E-1186[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 118,600 124,500 27,300 NA 2-5/8" 33 134.30 38.50 51.00 1,050
SM*36E-1225[ ]{ } 4.15 NA 4.15 9.00 NA NA 4.15 9.00 122,500 128,900 24,900 NA 2-5/8" 33 134.30 38.50 51.00 1,060
SM*34E-1393[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 139,300 146,300 27,400 NA 2-5/8" 48 134.30 38.50 51.00 1,195
SM*35E-1544[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 154,400 162,100 26,100 NA 2-5/8" 48 134.30 38.50 51.00 1,215
SM*36E-1594[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 159,400 167,800 25,800 NA 2-5/8" 48 134.30 38.50 51.00 1,240
**SM*44E-1465[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 146,500 167,000 38,130 NA (2) 2-1/8" 47 173.00 38.50 52.50 1,370
**SM*45E-1523[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 152,300 173,600 36,400 NA (2) 2-1/8" 47 173.00 38.50 52.50 1,340
**SM*46E-1754[ ]{ } 4.15 NA 4.15 9.00 NA NA 4.15 9.00 175,400 184,600 33,200 NA (2) 2-1/8" 47 173.00 38.50 52.50 1,400
**SM*44E-1769[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 176,900 201,800 36,530 NA (2) 2-1/8" 67 173.00 38.50 52.50 1,469
**SM*45E-1985[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 198,500 226,300 34,800 NA (2) 2-1/8" 67 173.00 38.50 52.50 1,540
**SM*46E-2307[ ]{ } 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 230,700 242,800 32,530 NA (2) 2-1/8" 67 173.00 38.50 52.50 1,600

* For motor code and refrigerant, use "D" when AWEF rating is shown and "A" for non-regulated applications or where AWEF is NA. Include fan motor heat of 4000 BTU/H per fan in room load calculations. De-rate capacity 12% for 50 Hertz operation
with 3 phase motors only. Four fan SM/SV models for low temperature requires two expansion valves. [ ] Location for the refrigerant letter code. { } 3 phase motor C is standard for non-regulated applications, include "V" for
Variable Speed EC control or "D" when Dual Speed control of the variable speed motor will be from a fixed 10 V signal.
** G Stock Units are for glide refrigerants only (consult I/O manual for complete refrigerant listing).
*** N Stock Units are for non-glide or glide refrigerants (consult I/O manual for complete refrigerant listing).

EXAMPLE FULL MODELS:


SMD36E-1225SVK is DOE / NRCan with R-404A, variable speed motors and 208/3/60 power.

Key Point -
Krack evaporator capacities shown are with midpoint evaporating temperature to offer a consistent capacity
for selection when using different refrigerants and match other Krack and Hussmann equipment.

5 SM/SV SERIES UNIT COOLERS


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Electric Defrost High Profile

LOW TEMPERATURE
Freezer AWEF by Refrigerant and Motor
[G] Stock Unit**, [N] Stock Unit***,
[Q] R-407A, [F] R-407F, [S] R-404A, REFRIGERATION
CAPACITY CAPACITY
[T] R-448A, [R] R-449A [P] R-507A CONNECTIONS DIMENSIONS (IN)
(BTU/H) (BTU/H) AIR REF SHIP
{D}ual {V}ariable {D}ual {V}ariable @ 10° F TD @ 10° F TD FLOW CHARGE WGT
SV MODEL Speed Speed Speed Speed -20° F EVAP +20° F EVAP (CFM) LIQ SUCT (LBS) L W H (LBS)
SV*14E-0422[ ]C NA 4.15 NA 4.15 42,200 - 11,250 NA 2-1/8" 13 77.00 38.50 40.50 440
SV*15E-0468[ ]C NA 4.15 NA 4.15 46,800 - 11,125 NA 2-1/8" 13 77.00 38.50 40.50 450
SV*16E-0664[ ]C NA 4.15 NA 4.15 66,400 - 11,000 NA 2-1/8" 13 77.00 38.50 40.50 530
SV*14E-0550[ ]C NA 4.15 NA 4.15 55,000 - 11,250 NA 2-1/8" 19 77.00 38.50 40.50 495
SV*15E-0611[ ]C NA 4.15 NA 4.15 61,100 - 11,125 NA 2-1/8" 19 77.00 38.50 40.50 505
SV*16E-0684[ ]C NA 4.15 NA 4.15 68,400 - 11,000 NA 2-1/8" 19 77.00 38.50 40.50 540
SV*24E-0834[ ]C NA 4.15 NA 4.15 83,400 - 24,225 NA 2-1/8" 24 134.30 38.50 40.50 836
SV*25E-0926[ ]C NA 4.15 NA 4.15 92,600 - 23,125 NA 2-1/8" 24 134.30 38.50 40.50 874
SV*26E-1005[ ]C NA 4.15 NA 4.15 100,500 - 22,800 NA 2-1/8" 24 134.30 38.50 40.50 912
SV*24E-1088[ ]C NA 4.15 NA 4.15 108,800 - 23,000 NA 2-1/8" 36 134.30 38.50 40.50 860
SV*25E-1206[ ]C NA 4.15 NA 4.15 120,600 - 22,000 NA 2-1/8" 36 134.30 38.50 40.50 900
SV*26E-1311[ ]C NA 4.15 NA 4.15 131,100 - 21,550 NA 2-1/8" 36 134.30 38.50 40.50 920
SV*34E-1177[ ]C NA 4.15 NA 4.15 117,700 - 35,750 NA 2-5/8" 33 134.30 38.50 51.00 1,030
SV*35E-1304[ ]C NA 4.15 NA 4.15 130,400 - 34,125 NA 2-5/8" 33 134.30 38.50 51.00 1,050
SV*36E-1418[ ]C NA 4.15 NA 4.15 141,800 - 33,400 NA 2-5/8" 33 134.30 38.50 51.00 1,060
SV*34E-1530[ ]C NA 4.15 NA 4.15 153,000 - 34,250 NA 2-5/8" 48 134.30 38.50 51.00 1,195
SV*35E-1698[ ]C NA 4.15 NA 4.15 169,800 - 32,625 NA 2-5/8" 48 134.30 38.50 51.00 1,215
SV*36E-1843[ ]C NA 4.15 NA 4.15 184,300 - 32,000 NA 2-5/8" 48 134.30 38.50 51.00 1,240
**SV*44E-1699[ ]C NA 4.15 NA 4.15 169,900 - 47,650 NA (2) 2-1/8" 47 173.00 38.50 52.50 1,370
**SV*45E-1883[ ]C NA 4.15 NA 4.15 188,300 - 45,500 NA (2) 2-1/8" 47 173.00 38.50 52.50 1,340
**SV*46E-2047[ ]C NA 4.15 NA 4.15 204,700 - 44,500 NA (2) 2-1/8" 47 173.00 38.50 52.50 1,400
**SV*44E-2052[ ]C NA 4.15 NA 4.15 205,200 - 45,650 NA (2) 2-1/8" 67 173.00 38.50 52.50 1,469
**SV*45E-2274[ ]C NA 4.15 NA 4.15 227,400 - 43,600 NA (2) 2-1/8" 67 173.00 38.50 52.50 1,540
**SV*46E-2472[ ]C NA 4.15 NA 4.15 247,200 - 42,700 NA (2) 2-1/8" 67 173.00 38.50 52.50 1,600

* For motor code and refrigerant, use "D" when AWEF rating is shown and "A" for non-regulated applications or where AWEF is NA.
SV models are available for use in non-regulated applications. 3 phase motors can be upgraded to Variable Speed EC motors for energy savings.
Include fan motor heat of 6600 BTU/H per fan in room load calculations. De-rate capacity 12% for 50 Hertz operation with 3 phase motors only.
Four fan SM/SV models for low temperature requires two expansion valves.
[ ] Location for the refrigerant letter code. { } 3 phase motor C is standard for non-regulated applications, include "V" for Variable Speed EC control
or "D" when Dual Speed control of the variable speed motor will be from a fixed 10 V signal.
** G Stock Units are for glide refrigerants only (consult I/O manual for complete refrigerant listing).
*** N Stock Units are for non-glide or glide refrigerants (consult I/O manual for complete refrigerant listing).

EXAMPLE FULL MODELS:


SVA36E-1418QCK is for non-regulated applications with R-407A, 3 phase motors and 208/3/60 power.

Key Point -
Krack evaporator capacities shown are with midpoint evaporating temperature to offer a consistent capacity
for selection when using different refrigerants and match other Krack and Hussmann equipment.

SM/SV SERIES UNIT COOLERS 6


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Hot Gas Defrost High Profile

LOW / MEDIUM TEMPERATURE


AWEF by Refrigerant, Motor, and Application
[G] Stock Unit**, [N] Stock Unit***,
[Q] R-407A, [F] R-407F, [S] R-404A,
[T] R-448A, [R] R-449A [P] R-507A
CAPACITY CAPACITY REFRIGERATION
{D}ual {V}ariable {D}ual {V}ariable CONNECTIONS DIMENSIONS (IN)
(BTU/H) (BTU/H) AIR REF SHIP
Speed Speed Speed Speed
@ 10° F TD @ 10° F TD FLOW DEFR CHARGE WGT
SM MODEL Freezer Cooler Freezer Cooler Freezer Cooler Freezer Cooler -20° F EVAP +20° F EVAP (CFM) GAS SUCT (LBS) L W H (LBS)
SM*14( )-0384[ ]C 4.15 NA 4.15 9.00 NA NA 4.15 9.00 38,400 40,300 9,690 1/2" 1-5/8" 13 77.00 38.50 40.50 440
SM*15( )-0426[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 42,600 44,700 6,250 1/2" 1-5/8" 13 77.00 38.50 40.50 450
SM*16( )-0440[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 44,400 46,300 8,810 1/2" 1-5/8" 13 77.00 38.50 40.50 470
SM*14( )-0501[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 50,100 52,600 9,330 7/8" 2-1/8" 19 77.00 38.50 40.50 495
SM*15( )-0556[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 55,600 58,400 8,900 7/8" 2-1/8" 19 77.00 38.50 40.50 505
SM*16( )-0574[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 57,400 60,400 8,400 7/8" 2-1/8" 19 77.00 38.50 40.50 530
SM*24( )-0759[ ]C 4.15 NA 4.15 9.00 NA NA 4.15 9.00 75,900 79,700 19,380 7/8" 2-1/8" 24 134.30 38.50 40.50 836
SM*25( )-0842[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 84,200 88,400 18,500 7/8" 2-1/8" 24 134.30 38.50 40.50 874
SM*26( )-0869[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 86,900 91,500 17,600 7/8" 2-1/8" 24 134.30 38.50 40.50 912
SM*24( )-0989[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 98,900 103,800 18,400 7/8" 2-5/8" 36 134.30 38.50 40.50 860
SM*25( )-1097[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 109,700 115,200 17,600 7/8" 2-5/8" 36 134.30 38.50 40.50 900
SM*26( )-1132[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 113,200 119,200 16,800 7/8" 2-5/8" 36 134.30 38.50 40.50 920
SM*34( )-1070[ ]C 4.15 NA 4.15 9.00 NA NA 4.15 9.00 107,000 112,300 28,600 7/8" 2-5/8" 33 134.30 38.50 51.00 1,030
SM*35( )-1186[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 118,600 124,500 27,300 7/8" 2-5/8" 33 134.30 38.50 51.00 1,050
SM*36( )-1225[ ]C 4.15 NA 4.15 9.00 NA NA 4.15 9.00 122,500 128,900 24,900 7/8" 2-5/8" 33 134.30 38.50 51.00 1,060
SM*34( )-1393[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 139,300 146,300 27,400 1-1/8" 2-5/8" 48 134.30 38.50 51.00 1,195
SM*35( )-1544[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 154,400 162,100 26,100 1-1/8" 2-5/8" 48 134.30 38.50 51.00 1,215
SM*36( )-1594[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 159,400 167,800 25,800 1-1/8" 2-5/8" 48 134.30 38.50 51.00 1,240
**SM*44( )-1465[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 146,500 167,000 38,130 (2) 7/8" (2) 2-1/8" 47 173.00 38.50 52.50 1,370
**SM*45( )-1523[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 152,300 173,600 36,400 (2) 7/8" (2) 2-1/8" 47 173.00 38.50 52.50 1,340
**SM*46( )-1754[ ]C 4.15 NA 4.15 9.00 NA NA 4.15 9.00 175,400 184,600 33,200 (2) 7/8" (2) 2-1/8" 47 173.00 38.50 52.50 1,400
**SM*44( )-1769[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 176,900 201,800 36,530 (2) 7/8" (2) 2-1/8" 67 173.00 38.50 52.50 1,469
**SM*45( )-1985[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 198,500 226,300 34,800 (2) 7/8" (2) 2-1/8" 67 173.00 38.50 52.50 1,540
**SM*46( )-2307[ ]C 4.15 9.00 4.15 9.00 NA NA 4.15 9.00 230,700 242,800 32,530 (2) 7/8" (2) 2-1/8" 67 173.00 38.50 52.50 1,600

* For motor code and refrigerant, use "D" when AWEF rating is shown and "A" for non-regulated applications or where AWEF is NA. Available Gas Defrost Types
( ) Gas defrost type K, H, G, or P. See definition to the right. [ ] Location for the refrigerant letter code. (H) - HGE 3 Pipe Hot Gas with Electric Pan Heat. No defrost termination or fan delay.
{ } Variable Speed EC motor is standard, include "V" for Variable Speed EC control or "D" when Dual Speed control from 10 V signal will be applied. (G) - HGG 3 Pipe Hot Gas with Gas Pan Heat. No defrost termination or fan delay.
** G Stock Units are for glide refrigerants only (consult I/O manual for complete refrigerant listing). (P) - KGE 2 Pipe Kool Gas with Electric Pan Heat.
*** N Stock Units are for non-glide or glide refrigerants (consult I/O manual for complete refrigerant listing). (K) - KGG 2 Pipe Kool Gas with Gas Pan Heat.

EXAMPLE FULL MODEL:


MKD36P-309QDAA is for DOE / NRCan application with R-407A,
Dual Speed EC motor and includes the additional letters AA for 208 V single phase power.

Key Point -
Krack evaporator capacities shown are with midpoint evaporating temperature to offer a consistent capacity
for selection when using different refrigerants and match other Krack and Hussmann equipment.

7 SM/SV SERIES UNIT COOLERS


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Fan Motor Data


MOTOR OPTIONS
3 PHASE MOTORS
MOTOR OPTIONS VARIABLE SPEED EC
SM 208/3/60 380/3/50 3 PHASE MOTORS
380/3/60 460/3/60 575/3/60 VARIABLE SPEED
208/3/60 EC
460/3/60
MODEL
SM 208/3/60
AMPS WATTS 380/3/50
AMPS 380/3/60
WATTS AMPS 460/3/60
WATTS AMPS WATTS 575/3/60
AMPS WATTS 208/3/60
AMPS 460/3/60
WATTS AMPS WATTS
MODEL AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS
1 FAN 4.8 1172 2.3 762 2.3 1172 2.4 1172 1.8 1172 5.4 1172 3.0 1172
12 FAN 9.6
4.8 2344
1172 4.6
2.3 1524
762 4.6
2.3 2344
1172 4.8
2.4 2344
1172 3.6
1.8 2344
1172 10.8
5.4 2344
1172 6.0
3.0 2344
1172
23 FAN 14.4
9.6 3516
2344 6.9
4.6 2285
1524 6.9
4.6 3516
2344 7.2
4.8 3516
2344 5.4
3.6 3516
2344 16.2
10.8 3516
2344 9.0
6.0 3516
2344
34 FAN 19.2
14.4 4688
3516 9.2
6.9 3047
2285 9.2
6.9 4688
3516 9.6
7.2 4688
3516 7.2
5.4 4688
3516 21.6
16.2 4688
3516 12.0
9.0 4688
3516
4 FAN 19.2 4688 9.2 3047 9.2 4688 9.6 4688 7.2 4688 21.6 4688 12.0 4688

3 PHASE MOTORS VARIABLE SPEED EC


SV 208/3/60 380/3/50 3 PHASE MOTORS
380/3/60 460/3/60 575/3/60 VARIABLE SPEED
208/3/60 EC
460/3/60
MODEL
SV 208/3/60
AMPS 380/3/50
WATTS AMPS WATTS AMPS380/3/60 460/3/60
WATTS AMPS WATTS 575/3/60
AMPS WATTS 208/3/60
AMPS 460/3/60
WATTS AMPS WATTS
MODEL AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS
1 FAN 5.4 1935 2.1 1260 2.5 1935 2.5 1935 2.2 1935 5.4 1935 3.0 1935
12 FAN 10.8
5.4 3870
1935 4.2
2.1 2520
1260 5.0
2.5 3870
1935 7.0
2.5 3870
1935 4.4
2.2 3870
1935 10.8
5.4 3870
1935 6.0
3.0 3870
1935
32 FAN 16.2
10.8 5805
3870 6.3
4.2 3780
2520 7.5
5.0 5805
3870 10.5
7.0 5805
3870 6.6
4.4 5805
3870 16.2
10.8 5805
3870 9.0
6.0 5805
3870
34 FAN 21.6
16.2 7740
5805 8.4
6.3 5040
3780 10.0
7.5 7740
5805 14.0
10.5 7740
5805 8.8
6.6 7740
5805 21.6
16.2 7740
5805 12.0
9.0 7740
5805
4 FAN 21.6 7740 8.4 5040 10.0 7740 14.0 7740 8.8 7740 21.6 7740 12.0 7740
Variable Speed EC motors are motor codes "V" and "D" will use 0-10 V speed signal with 0 V or no signal full speed.
Variable Speed EC motors are motor codes "V" and "D" will use 0-10 V speedRefer
signalto with
complete
0 V orModel Key full
no signal on page 2.
speed.
Refer to complete Model Key on page 2.

Key Point -
EC motors will operate variable speed with a 0-10 V signal or Dual Speed by providing a 10 V signal for minimum speed operation.
Operation will be the same as a single speed motor without a control signal.

Electric/Hot Gas Defrost Heater Data

ELECTRIC DEFROST
ELECTRIC DEFROST (E)
230/3/60 380/3/50-60 460/3/60 575/3/60
MODEL AMPS KW AMPS KW AMPS KW AMPS KW
384, 426, 440, 501, 556, 574
1 FAN 34.7 13.8 19.8 13.0 17.3 13.8 13.9 13.8
422, 438, 550, 611, 664
759, 842, 869, 989, 1097, 1132 1 @ 42.2 1 @ 16.8
2 FAN 36.6 24.1 32.0 25.5 25.6 25.5
834, 926, 1005, 1088, 1206, 1311 1 @ 21.9 1 @ 8.7
1070, 1186, 1225, 1177, 1304, 1418 1 @ 42.2 1 @ 16.8 43.0 28.3 37.4 29.7 29.9 29.7
3 FAN
1393, 1544, 1594, 1530, 1698, 1843 1 @ 32.5 1 @ 12.9
1465, 1523, 1754, 1699, 1883, 2047 2 @ 40.7 2 @ 16.2 1 @ 32.8 1 @ 21.6
4 FAN 47.8 38.1 38.3 38.1
1769, 1985, 2307, 2052, 2274, 2472 1 @ 14.3 1 @ 5.7 1 @ 22.3 1 @ 14.7

HOT GAS DEFROST


PAN HEATER (H AND P)
230/3/60 380/3/50-60 460/3/60 575/3/60
MODEL AMPS KW AMPS KW AMPS KW AMPS KW
1 FAN 384, 426, 440, 501, 556, 574 6.4 2.6 2.7 1.8 3.2 2.6 2.6 2.6
2 FAN 759, 842, 869, 989, 1097, 1132 11.3 4.5 4.6 3.0 5.6 4.5 4.5 4.5
3 FAN 1070, 1186, 1225, 1393, 1544, 1594 11.3 4.5 4.6 3.0 5.6 4.5 4.5 4.5
4 FAN 1465, 1523, 1754, 1769, 1985, 2307 14.3 5.7 5.9 3.9 7.2 5.7 5.7 5.7

Electrical information for electric defrost type "E".


Electrical information for pan heaters on defrost type "P" and "H".
Refer to complete Model Key on page 2.

SM/SV SERIES UNIT COOLERS 8


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Dimensional Data
11/16 DIA. MOUNTING HOLES

ACCESS DOOR
(BOTH SIDES)

ELECTRICAL STANDARD DISTRIBUTOR


KNOCKOUTS FAN GUARD INLET CONN.

OPTIONAL
AIR THROW
BOOSTER
AIR
FLOW

DRAIN PAN 1.25 FPT DRAIN SUCTION


CONNECTION CONN.

UNIT DIMENSIONS
SIZE A UNIT DIMENSIONS
B C D E
SIZE A B C D E
1 FAN 77.00 60.00 1 @ 60.00 40.50 34.00
1 FAN 77.00 60.0
2 FAN 134.25 117.00 1 @ 60.00 40.50
2 @ 58.50 34.00
40.50 34.00
2 FAN 134.25 117.0 2 @ 58.50 40.50 34.00
3 FAN
3 FAN 134.25
134.25 117.0
117.00 3 @ 39.00 3 @ 39.00
52.50
52.50
46.00
46.00
44FAN
FAN 173.00173.00 156.0 156.00 4 @ 39.00 4 @ 39.00
52.50 52.50
46.00 46.00

Note: Alldimensions
Note: All dimensions in inches.
in inches.

9 SM/SV SERIES UNIT COOLERS


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Wiring DiagramsSM - MOTOR


SM - MOTOR RPM RPM
V1 = 850V1RPM
= 850 V2
RPM= 425
V2RPM
= 425 RPM
SV - MOTOR
SV - MOTOR RPM RPM
3 Phase Motor Wiring - Motor Code C V1 RPM
V1 = 1140 = 1140 V2
RPM= 575
V2RPM
= 575 RPM

Dual Speed Variable Speed EC Motor Wiring - Motor Code D

SM - MOTOR RPM
V1 = 850 RPM V2 = 425 RPM
SV - MOTOR RPM SM - MOTOR
SM - MOTOR RPM RPM
V1 = 1140 RPM V2 = 575 RPM 0VRPM
= 85010V
RPM= 425
10VRPM
= 425 RPM
0V = 850
SV - MOTOR
SV - MOTOR RPM RPM
0V RPM
0V = 1140 = 114010V
RPM= 570
10VRPM
= 570 RPM

MOTOR RPM
RPM 10V = 425 RPM
MOTOR RPM
RPM 10V = 570 RPM

SM/SV SERIES UNIT COOLERS 10


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Wiring Diagrams
Variable Speed EC Motor Wiring - Motor Code V

SM - MOTOR RPM
0V = 850 RPM 10V = 425 RPM
SV - MOTOR RPM
0V = 1140 RPM 10V = 570 RPM

Variable Speed EC Motor Wiring - Motor Code V


Electric Defrost with System 450 Control

24V Sn2
C C
Sn1 Sn3
C 5V

24V Sn2 24V Sn2


C C C C
Sn1 Sn3 Sn1 Sn3
C 5V C 5V

24V Sn2
C C
Sn1 Sn3
C 5V

11 SM/SV SERIES UNIT COOLERS


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Wiring Diagrams
Heater Wiring

Gas Defrost Setup

H and P Defrost Control Wiring - G and K Defrost Control Wiring -


Gas Defrost with Electric Drain Pan Heater Gas Defrost with Gas Drain Pan Heater

3 Pipe Hot Gas Defrost


with Electric Defrost Drain Pan (H)

SM/SV SERIES UNIT COOLERS 12


Specifications subject to change without notice.
SM/SV Series Unit Coolers

Notes

13 SM/SV SERIES UNIT COOLERS


Specifications subject to change without notice.
SM/SV SERIES UNIT COOLERS
Specifications subject to change without notice.
Use your QR reader to
reference current document
version on www.krack.com.

Krack, a Hussmann Corporation brand


1049 Lily Cache Lane, Suite A
Bolingbrook, Illinois 60440
Ph: 630.629.7500

www.krack.com
www.hussmann.com

Printed in U.S.A. ©2020 Krack, a Hussmann Corporation brand SMSV_012_121820