The document outlines technical specifications for a 10,000 MT capacity ammonia storage tank. It specifies that the vendor must appoint a third party inspection agency to inspect the tank. It also lists many requirements for the contractor building the tank, including supplying materials, equipment, and drawings for statutory approvals. Finally, it provides a list of process deliverables that the contractor must provide, such as process design basis, piping and instrumentation diagrams, and hazardous area classification drawings.

Uploaded by

VPNN 789
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views1 page

LSTK D1003am1

The document outlines technical specifications for a 10,000 MT capacity ammonia storage tank. It specifies that the vendor must appoint a third party inspection agency to inspect the tank. It also lists many requirements for the contractor building the tank, including supplying materials, equipment, and drawings for statutory approvals. Finally, it provides a list of process deliverables that the contractor must provide, such as process design basis, piping and instrumentation diagrams, and hazardous area classification drawings.

Uploaded by

VPNN 789
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Annexure- 4

Technical Specifications for 10,000 MT Capacity Ammonia Storage Tank


GNFC Weigh Bridge. Measuring of final plate weight shall be done on theoretical
tonnage basis only.

2.24 Vendor has to appoint Third Party Agency (TPIA) M/s Lloyd`s Register for
Inspection as per inspection categorize plan attached at Annexure I2.

2.25 All the drawings & documents required for contractor to study and understand the
subject tender is enclosed herewith at Annexure-10.

2.26 New tank layout, piping interconnection layout, procurement, fabrication,


inspection and testing, erection, supports, painting, insulation for Integration /
interconnection of new Ammonia tank piping to existing facility.

2.27 Contractor shall consider the plate size for tank as minimum 8 M long and 3 M
wide. However, if this is not possible than contractor shall get approval of GNFC
for using lower length / width of the plates.

2.28 Arrangement & supply of all materials, tools, tackles, all the cranes, hydra,
winches and hydraulic jacking system for tank erection, other lifting equipment,
manpower, welding machines with consumable such as electrodes, filler wires,
industrial gases for cutting and welding, grinding wheels, DP solution etc,
scaffolding, measuring instruments & other necessary attachments & instruments
including concrete ring for sealing of sand between outer & inner tank bottom
plates & sand filling etc. whatsoever required for completion of job. The concrete
ring shall have low temperature properties suitable to design conditions of tank.

2.29 Drawings and documents shall be submitted by contractor to GNFC which are
required for taking statutory approvals of factory inspector etc. Contractor will
assist GNFC in all respect to get all statutory approval in time.

2.30 List of process deliverables by LSTK contractor for review:

a) Process Design Basis


b) Process Description
c) Equipment List
d) Process Flow Diagram
e) Utility Flow Diagram
f) Heat & Mass Balance
g) Boil-off Gas Calculation
h) Piping & Instrumentation Diagram(Process & Utility)
i) Line list
j) Hydraulic Summary Report
k) Operation & Control Philosophy
l) Cause &Effect Matrix
m) Alarm & Trip set point summary
n) Hazardous Area Classification drawing

08_Tech_Spec_LSTK_D1003AM1_Annexure-4 Page 8 of 26