Daikin Quick Selection Guide
Daikin Quick Selection Guide
Selection
Guide
High Ambient (46° OD)
Split Units VRV Rooftop Air Handling Units Air Cooled Chillers Water Cooled Chillers Modular Chiller Plant Service
Daikin world
Supermarket Factory
Technical
Sport &
Home Office Leisure
The perfect working environment is essential for all
businesses. From supermarkets to offices, from public
buildings to hotels, from factories to data centers,
it is essential that the quality of the air is optimised at all
times – but no space is used in exactly the same way and
that calls for flexible, tailored and economic solutions.
Daikin, the innovation leader for more than 90 years, understands
this and its ‘total solution’ concept is built around customised
solutions for individual clients. Whether cooling, heating, ventilation,
air curtains or refrigeration with intelligent control systems.
Daikin has the units, the experience and the solution for
you. Learn all about our solutions for your business.
Our promise...
... is to ensure that customers can depend on Daikin
for the ultimate in comfort, so that they are free to
focus on their own working and home lives.
We promise to dedicate ourselves to technological excellence,
a design focus and the highest quality standards so that our
customers can trust and rely on the comfort we deliver.
Our promise to the planet is absolute. Our products are at the
forefront of low energy-usage and we will innovate to further reduce
the environmental impact of HVAC-R (Heating, Ventilation, Air
conditioning, Refrigeration) solutions. We lead where others follow.
Product Range 6
DX Systems 14
Split Units 16
Rooftop (Packaged Unit) 18
VRV Systems
VRV IV Outdoor Unit 20
Wall Mounted Series 22
Ducted Series 24
Cassette Series 25
Air Purifier 26
Applied Systems 28
Air Cooled Chillers 30
Water Cooled Centrifugal Chillers 33
Chilled Water Fan Coil Units 34
Air Handling Units 36
Technical Information 52
*(R): Oman, Kuwait models, *(9): Bahrain, Qatar models, *(RE): UAE models R-32 Refrigerant R-410A
VRV IV
Series Product Picture 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42
Water Cooled (HP)
FXFQ-A
Ceiling Mounted Cas-
sette
FXZQ-A
FXDQ-A
FXSQ-A
Concealed Ceiling Unit
FXMQ-P7
FXMQ-MA/PVE
FXAQ-PVER1
Wall Mounted
FXAQ-PVE
FXHQ-A
Ceiling Suspended
FXUQ-A
FXLQ-P
Floor Standing
FXNQ-A
EWAD-M 219-423 TR
EWAD-MZ
103-322 TR
Water Cooled Cooling Capacity, TR (Nominal), CHW in/out 12/7°C, CW in: 29.4°C, CW Flow 3 GPM/TR
Product Picture
Chillers - Screw 50 100 150 200 250 300 350 400 450 500 550 600 650 750
EWWD-G 46-171 TR
EWWD-I 95-430 TR
EWWQ-B 108-617 TR
EWWD-VZ
127 - 588 TR
WMC / WME
(Magnetic Bearing)
100-650 TR
WSC 200-1250 TR
WTC 1200-1600 TR
WDC 400-2500 TR
WCC1200-2700 TR
WCT 2800-3000 TR
Refrigerant R-134A
R-134a
FWF-C
2/3/4/5/6
2/4/5
Chilled Water Fan Coil Units Product Picture CFM 200 300 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 2500 3000 4000 4600
FWK-E/
FWKE-E/ 5/6/8/9/11/13
FWW-DA FWKE-EH
FWE-E 5/6/7/8/10/12
FWW-C / F / H
FWE-D 7/9/13
2/2.5/3.5
FWC-FD FWC-FD /4/5/7/8
FUD-B 20/25/30/40
FUD
FWE
Air Handing Units Product Picture CFM 300 650 1000 5000 10000 15000 20000 25000 30000 35000 40000 50000 53000 60000 70000 80000 83000
D-AHU 2
DDM-AHU
Refrigerant R-410A
DX Systems
Daikin offers the best available technologies for
» Inverter
split system?
» Powerful cooling performance, capacity and efficiency,
regardless of the outside temperature
» Intelligent Eye
» Daikin further enhances efficiency while
keeping comfort optimal by offering smart
technology like intelligent eye, which is able
to adjust the room temperature based on the
occupancy.
BEST AVAILABLE TECHNOLOGY FTKM28PVMK RKM28PVMK 2.33 7.18 5.71 727 343 2.68
Wall Mounted FTNK20AV1K (R / 9) RNK20AV1K (R / 9) 1.50 3.66 3.20 474 224 1.91
(Non-Inverter)
R-410A
Premium
Rotary FTNK25AV1K (R / 9) RNK25AV1K (R / 9) 2.00 4.70 4.00 537 267 2.51
FTN20AV1K (R) (9) RN20AV1K (R / 9) 1.50 3.66 3.20 474 224 1.91
(Non-Inverter) R-410A
Rotary
FTN30AV1K (R) RN30AV1K (R) 2.33 6.11 6.11 760 359 3.28
FTN-AV1 30
FTN-AV1 30
» Nominal Conditions (T1): 35 °C ambient and on coil of 27/19 DB/WB °C » Piping Limitation: Wall Mounted
» Actual Conditions: 46 °C ambient and on coil of 24/16 DB/WB °C at medium speed
» All units up to 3TR nominal capacity are 220-240V/1Ph/50Hz and above are 380-415V/3Ph/50Hz
» (R): Oman / Kuwait models
» (9): Bahrain / Qatar models
3.91 13.35 - 1/4" 1/2" 42 1050 259 340 15 930 350 695 46
3.72 12.70 - 1/4" 1/2" 45 1050 259 340 15 930 350 695 49
3.55 12.12 - 1/4" 5/8" 49 1200 259 340 18 930 350 695 49
3.23 11.04 - 1/4" 1/2" 39 1172 242 320 14 855 328 651 49
3.28 11.21 - 1/4" 5/8" 43 1172 242 320 14 855 328 753 57
3.23 11.04 - 1/4" 1/2" 39 1124 237 310 14 855 328 651 49
3.28 11.21 - 1/4" 5/8" 43 1124 237 310 14 855 328 753 57
2.88 9.84 - 3/8" 5/8" 46 1289 240 310 16 1030 400 852 77
Ducted Split
FBQ48EVM RZR48MYM 3.1 8.78 8.39 1378 650 3.5
3.53 12.04 50 3/8 5/8 - 1400 700 300 46 1170 320 900 101
› VRV configurator
+ VRV IV core
technologies
› Newly developed inverter compressor
› 4 sided condenser coil
› Outer rotor DC Motor
+ Total Building
Solution
› Indoor line-up
› Fresh air
› Controls
VRV IV Systems
Consultants » Technical design support
Daikin’s VRV IV technology maximises » Ecological design meets and exceeds legal requirements
flexibility and leads the way in customisation » Maximum flexibility to meet customer requirements
to match individual building requirements in » Advance software tools assist with system design
comfort and energy, with reduced running » Complies with ESMA UAE regulations
costs. » Complies with MEW-Kuwait regulations
» Complies with SASO Saudi regulations
» Complies with QCC AD-UAE regulations
VRV IV Systems
Nom Power Input COP COP (ESMA)
Capacity Length Width Height Weight Combination
Capacity (ESMA) (Eurovent) ISO15042:2011
Models
TR at kW at No of
kW at 46°C at 35°C at 46°C mm mm mm kg Models
35°C 46°C Modules
RXYSQ8TMY1B 6.4 16.22 5.75 3.66 2.82 320 940 1430 144 RXYSQ8TY1 1
RXYSQ10TMY1B 8.0 19.72 7.04 3.40 2.80 320 940 1430 178 RXYSQ10TY1 1
RXYSQ12TMY1B 9.5 22.51 8.17 3.30 2.76 460 940 1815 180 RXYSQ12TY1 1
Models
FXAQ-PVE TC
kW
TC
MBH
SC
(kW)
SC
(MBH)
TC kW
TC
MBH
SC
(kW)
SC
(MBH)
kW cfm L/s mm mm mm dBA kg
FXAQ20PVE 2.2 7.5 1.9 6.5 2 6.8 1.7 5.8 0.019 275 130 795 238 290 29 11
FXAQ25PVE 2.8 9.6 2.2 7.5 2.5 8.5 2.0 6.8 0.028 283 133 795 238 290 29 11
FXAQ32PVE 3.6 12.3 2.7 9.2 3.2 10.9 2.4 8.2 0.03 318 150 795 238 290 29 11
FXAQ40PVER1 4.5 15.4 3.5 11.9 3.9 13.3 3.1 10.6 0.020 424 200 1050 238 290 34 14
FXAQ50PVER1 5.6 19.1 4.2 14.3 4.9 16.7 3.8 13.0 0.033 530 250 1050 238 290 36 14
FXAQ63PVER1 7.1 24.2 5.3 18.1 6.2 21.2 4.7 16.0 0.050 671 317 1050 238 290 39 14
*Actual capacity depends only on outdoor unit.
VRV IV Systems
FXMQ-P/MA TC
kW
TC
MBH
SC
kW
SC
MBH
TC
kW
TC
MBH
SC
kW
SC
MBH
Pa mm mm mm dBA kg
FXMQ50P 5.6 19.1 4.6 15.7 4.9 16.7 4.1 14.0 0.11 636 300 100-200 1000 700 300 39 42
FXMQ63P 7.1 24.2 5.5 18.8 6.2 21.2 5.0 17.1 0.12 689 325 100-200 1000 700 300 40 42
FXMQ80P 9 30.7 7.0 23.9 7.8 26.6 6.3 21.5 0.171 883 417 100-200 1000 700 300 41 42
FXMQ100P 11.2 38.2 8.5 29.0 9.8 33.4 7.5 25.6 0.176 1130 533 100-200 1400 700 300 41 54
FXMQ125P 14 47.8 10.5 35.8 12.2 41.6 9.4 32.1 0.241 1377 650 100-200 1400 700 300 44 54
FXMQ140PVE* 16 54.6 12.0 40.9 14 47.8 10.7 36.5 0.461 1624 767 100-200 1400 700 300 45 47
FXMQ200MA** 22.4 76.4 16.8 57.3 19.5 66.5 15.1 51.5 1.3 2048 967 132-221 1380 1100 470 48 137
FXMQ250MA** 28 95.5 20.9 71.3 24.4 83.3 18.8 64.1 1.5 2543 1200 191-270 1380 1100 470 48 137
*Air filter & drain pump option
** Air filter option
Air Purifier
generating high speed electrons, a feat that has been
the considered difficult up to now. Destroys
• Super quiet 99.6% of allergy
operation
espiratory
air and • Easy to Odours
maintain neutralization
o: Main specifications
• PortableUltra quiet operation (16dBA)
Daikin has already received great praise for its air
purifiers: a British Allergy Foundation seal of approval Portable (8.5 KG)
• No installation
and the TÜV Nord test mark confirm the efficiency of
our units. No need of installation
Easy maintenance
Indoor unit MC70L
Applicable room area Economical m² 46
Dimensions Unit HeightxWidthxDepth mm 576x403x241
Weight Unit kg 2 8.5
Casing Colour White
Fan Type Multi Blade Fan (Sirocco fan with shroud assembly)
Air flow rate Air Turbo/High/ m³/h
purifying Medium/Low/ 420/285/210/130/55
operation Silent
15
QUICK SELECTION GUIDE 27
Chillers
No matter how large your premises and whatever your air
Daikin chillers offer the ultimate in reliability and conditioning needs in climate control or process cooling and
heating, there is a system that has proved worthy in a multiplicity
flexibility — a reflection of the advanced technology
of situations - from industrial sites to retail warehouses, hotels and
inherent within them. Daikin chillers represent the sure department stores.
Applied Systems
› In-house development and manufacturing of chiller main components (compressors, fans
condenser coils, software, etc.)
Applied Systems
EWADC21C-XS 501.70 84.2 2540 x 2285 x 14785 12600 13470 81
EWADC22C-XS 514.50 86.3 2540 x 2285 x 14785 12600 13470 81
Cooling capacity is based on 46 °C ambient temperature, and water in/out at 7/12 °C
Refrigerant R-134A
WSC 200 TR - 1250 TR WTC 1200 - 1600 TR WDC: 400 TR - 2500 TR WCC: 1200 TR - 2700 TR
» Daikin exclusive compressor design » Movable discharge diffuser for better unloading » NPLV of up to 0.33 kW/TR
» R-134A - No Phase-out Refrigerant » Dual Compressor option from 400 TR capacity » Virtually maintenance free operation
» Semi-hermetic Compressor » Touch screen control display as standard » AHRI-certified performance
» Gear driven impeller » AHRI certified performance
Applied Systems
WMC/WME 100 - 650 TR WCT 2800 - 3000 TR
» Oil free magnetic bearing compressor » Exclusive TWO stage compressor design
» Inverter driven DC brushless compressor » R-134A - No Phase-out Refrigerant
motor » Semi-hermetic compressor
» Semi hermetic design » Refrigerant cooled oil cooler
» Sustainable performance » Movable discharge diffuser for better
» Low sound levels unloading
» NPLV of up to 0.33 kW/TR » Dual Compressor Chiller
» Virtually maintenance free operation » Touch screen control display as standard
» AHRI-certified performance » AHRI-certified performance
Applied Systems
Water Rated Sound
Water
Air Flow Cooling Capacity Pressure Power Pressure Dimensions
flow Weight
Models Model Image Drop Input Level
Total Sensible Length Depth Height
CFM l/s m3/h kPa kW db(A)
kW kW mm mm mm kg
FWE06E 530 250 3.76 3.06 0.18 26.7 0.108 43 1090 630 212 27
FWE07D 690 326 5.41 4.13 0.26 31.3 0.121 50 1214 670 249 45
FWE07E 560 264 3.86 3.21 0.18 31.1 0.115 46 1090 630 212 27
FWE08E 750 354 4.86 4.14 0.23 17.4 0.157 47 1320 635 259 41
FWE10E 980 463 6.87 5.44 0.33 25.5 0.187 47 1538 635 259 46
FWE12E 1080 510 10.45 7.43 0.5 40 0.25 50 1786 635 259 53
FWE13D 1020 481 10.07 7.49 0.48 24.3 0.193 53 1714 670 249 70
Above performance data is based on following conditions: » 220V/1ph/50Hz
» Cooling : 24°C DB / 17°C WB and water inlet 7°C outlet 12°C » Sound pressure level is tested at microphone position 1m in front of the unit and 1m below the air discharge opening
» Medium speed, 0 Pa ESP
Applied Systems
1620x2140 6000 11.00 88.07 81.02 13/12.6 2.34 36 1610 x 2140 x 2990 897
1740x2260 7000 11.00 106.41 93.64 13/12.43 2.82 48 1740 x 2260 x 2990 948
1740x2540 8000 11.00 117.43 108.04 13/12.6 3.11 49 1740 x 2540 x 3210 1111
1870x2630 9000 15.00 132.44 120.52 13/12.59 3.51 40 1870 x 2630 x 3210 1177
2050x2620 10000 15.00 146.58 134.85 13/12.61 3.89 39 2050 x 2620 x 3210 1209
2090x2890 11000 18.50 161.92 147.35 13/12.59 4.29 46 2090 x 2890 x 3260 1444
2210x2940 12000 18.50 185.86 161.70 13/12.35 4.93 42 2210 x 2940 x 3370 1592
AHUs include Prefilter (G4)+ Bag Filter (F7) + Cooling Coil + DWDI, Backward Curved Fan
Applied Systems
1620x2140 6000 11.00 106.51 82.70 13/11.55 1610 x 2140 x 2910 868
1740x2260 7000 11.00 124.16 96.49 13/11.56 1740 x 2260 x 3050 987
1740x2540 8000 11.00 141.36 110.27 13/11.58 1740 x 2540 x 3170 1115
1870x2630 9000 15.00 158.47 124.06 13/11.60 1870 x 2630 x 3170 1178
2050x2620 10000 15.00 176.32 137.84 13/11.59 2050 x 2620 x 3170 1217
2090x2890 11000 18.50 192.91 151.62 13/11.62 2090 x 2890 x 3220 1446
2210x2940 12000 18.50 209.81 165.41 13/11.64 2210 x 2940 x 3360 1582
2220x3160 13000 22.00 220.00 171.03 13.5/11.83 2220 x 3160 x 3360 1664
AHU's include Prefilter (G4)+ Bag Filter (F7) + DX Cooling Coil + DWDI, Backward Curved Fan
l/s l/s kW kW °C °C °C °C
°C °C kW kW °C °C l/s kPa mm kg
31.5/21.67 21/16 21.20 12.90 24.2/19.4 13.7/13.49 1.01 30 1550 x 1290 x 3810 825
32.5/22.2 21/16 35.00 21.00 25.2/20.1 13.7/13.7 1.67 33 1520 x 1500 x 3880 960
32.5/22.2 21/16 46.88 28.13 25.2/20.1 13.7/13.67 2.24 30 1700 x 1670 x 4110 1136
32.5/22.43 21/16 60.44 35.06 25.2/20.3 13.7/13.7 2.89 44 1840 x 1830 x 4150 1349
32.5/22.43 21/16 72.53 42.07 25.3/20.6 13.7/13.7 3.46 25 1960 x 1970 x 4470 1556
32.4/22.35 21/16 83.16 49.06 25.1/20.2 13.7/13.7 3.97 30 2310 x 2080 x 4470 1715
32.4/22.35 21/16 95.04 56.07 25.1/20.2 13.7/13.7 4.54 37 2380 x 2210 x 4730 1965
32.4/22.35 21/16 107.27 63.29 25.1/20.2 13.7/13.67 5.12 44 2620 x 2310 x 4730 2088
32.4/22.35 21/16 118.79 70.09 25.1/20.2 13.7/13.7 5.67 25 2680 x 2420 x 4800 2226
32.4/22.35 21/16 142.55 84.10 25.1/20.2 13.7/13.7 6.81 23 2660 x 2620 x 4930 2561
32.4/22.35 21/16 166.31 98.12 25.1/20.2 13.7/13.7 7.94 29 2990 x 2800 x 5230 2980
32.5/22.43 21/16 193.42 112.18 25.2/20.3 13.7/13.7 9.23 38 3180 x 2970 x 5430 3304
Applied Systems
32.6/22.51 21/16 221.37 128.39 25.3/20.4 13.7/13.7 10.57 37 3220 x 3120 x 5550 3562
32.4/22.35 21/16 245.97 142.66 25.3/20.4 13.7/13.7 11.74 44 3520 x 3300 x 5780 4218
32.4/22.35 21/16 261.55 154.31 25.1/20.2 13.7/13.7 12.49 49 3680 x 3500 x 5810 4695
l/s l/s kW kW °C °C °C °C
°C °C kW kW °C °C l/s kPa mm kg
32.4/22.35 21/16 285.11 168.21 25.1/20.2 13.7/13.7 13.61 21 3800 x 3630 x 5950 4998
32.4/22.35 21/16 308.86 182.23 25.1/20.2 13.7/13.7 14.75 14 3920 x 3760 x 6120 5361
32.4/22.35 21/16 332.62 196.25 25.1/20.2 13.7/13.7 15.88 16 4060 x 3890 x 6120 5604
32.4/22.35 21/16 356.38 210.26 25.1/20.2 13.7/13.7 17.01 19 4120 x 4010 x 6270 5898
32.4/22.35 21/16 380.14 224.28 25.1/20.2 13.7/13.7 18.15 21 4300 x 4130 x 6310 6349
32.4/22.35 21/16 403.90 238.30 25.1/20.2 13.7/13.7 19.28 23 4420 x 4240 x 6310 6406
32.4/22.35 21/16 427.66 252.32 25.1/20.2 13.7/13.7 20.42 26 4720 x 4350 x 6920 6933
32.5/22.43 21/16 459.36 266.43 25.2/20.3 13.7/13.7 21.93 19 4560 x 4460 x 6920 7227
32.24/23.68 21/16 569.69 274.48 24.9/21.6 13.7/13.7 28.49 25 4620 x 4560 x 5990 7124
32.2/23.65 21/16 626.52 288.20 24.9/21.6 13.7/13.7 29.91 34 4640 x 4720 x 5960 7391
32.17/23.62 21/16 656.36 301.93 24.9/21.6 13.7/13.7 31.34 38 4580 x 4930 x 5960 7603
32.3/23.76 21/16 696.39 320.34 25.0/21.7 13.7/13.7 33.25 44 4600 x 5180 x 6100 7840
Applied Systems
32.4/23.81 21/16 737.36 339.19 25.1/21.8 13.7/13.7 35.19 50 4600 x 5390 x 6100 8112
32.3/23.77 21/16 756.95 348.20 25.0/21.7 13.7/13.7 36.14 44 4620 x 5600 x 6130 8728
l/s l/s kW kW °C °C °C °C
°C °C kW kW °C °C l/s kPa mm kg
28.2/22.1 19.8/15.6 24.29 10.20 22.0/20.3 13.7/13.7 1.16 39 1440 x 1290 x 3710 800
28.3/21.9 19.8/15.6 35.79 15.75 22.2/20.2 13.7/13.7 1.71 35 1520 x 1500 x 3830 948
28.1/21.9 19.8/15.6 47.74 20.53 22.0/20.2 13.7/13.7 2.28 31 1700 x 1670 x 4090 1211
28.4/22.8 19.8/15.6 70.40 26.75 22.4/21.2 13.7/13.7 3.36 25 1840 x 1830 x 4100 1377
28.3/22.5 19.8/15.6 81.86 31.93 22.3/21.0 13.7/13.7 3.91 31 2080 x 1970 x 4240 1561
28.3/22.6 19.8/15.6 93.99 36.66 22.2/20.9 13.7/13.7 4.49 38 2310 x 2080 x 4530 1706
28.3/22.52 19.8/15.6 109.15 42.57 22.3/21 13.7/13.7 5.21 48 2460 x 2290 x 4670 2102
28.4/22.8 19.8/15.6 122.79 47.89 22.3/21 13.7/13.7 5.86 27 2700 x 2390 x 4670 2215
28.3/22.59 19.8/15.6 134.28 52.37 22.2/20.9 13.7/13.7 6.43 22 2760 x 2500 x 4740 2362
28.4/22.79 19.8/15.6 161.11 62.83 22.3/20.9 13.7/13.7 7.69 29 2730 x 2700 x 4910 2682
28.3/22.59 19.8/15.6 191.01 74.49 22.3/21 13.7/13.7 9.12 37 3070 x 2880 x 5210 3127
28.4/22.94 19.8/15.6 225.30 83.36 22.3/21.2 13.7/13.7 10.76 42 3270 x 3050 x 5410 3478
Applied Systems
28.5/23.23 19.8/15.6 261.37 96.71 22.4/21.4 13.7/13.7 12.48 53 3240 x 3200 x 5520 3898
28.4/23.01 19.8/15.6 281.62 104.20 22.3/21.2 13.7/13.7 13.45 42 3600 x 3300 x 5790 4448
28.4/22.94 19.8/15.6 309.78 114.62 22.3/21.2 13.7/13.7 14.79 42 3680 x 3500 x 5820 4764
l/s l/s kW kW °C °C °C °C
FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Heat Recovery * Other Heat Recovery options are available upon request :
Wheel + Chilled Water Coil + DWDI, Backward Curved Fan. » Plate Heat Exchanger
» Run around coil
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + DWDI, » Vertical heat pipe
Backward Curved Fan.
°C °C kW kW °C °C l/s kPa mm kg
28.4/22.91 19.8/15.6 337.95 125.04 22.3/21.2 13.7/13.7 16.13 48 3800 x 3630 x 5960 5052
28.4/22.96 19.7/15.6 366.06 139.10 22.4/21.2 13.7/13.7 17.48 17 3920 x 3760 x 6100 5423
28.4/22.91 19.8/15.6 394.27 145.88 22.3/21.2 13.7/13.7 18.82 20 4060 x 3890 x 5910 5688
28.4/22.92 19.8/15.6 422.43 156.30 22.3/21.2 13.7/13.7 20.17 23 4120 x 4010 x 6420 6095
28.4/22.87 19.8/15.6 443.58 168.56 22.3/21.2 13.7/13.7 21.18 15 4300 x 4130 x 6620 6620
28.4/22.89 19.8/15.6 478.76 177.14 22.3/21.2 13.7/13.7 22.86 17 4360 x 4230 x 6150 6494
28.5/23.13 19.8/15.6 522.74 193.41 22.4/21.4 13.7/13.7 24.96 20 4380 x 4330 x 5700 6186
28.5/23.29 19.8/15.6 568.69 204.73 22.4/21.6 13.7/13.7 27.15 23 4440 x 4430 x 5820 6479
29.70/25.43 20.3/15.8 764.50 252.29 24.0/23.4 13.7/13.7 36.50 39 4560 x 4510 x 5820 6683
29.70/25.41 20.4/15.8 802.72 264.90 24.0/23.4 13.7/13.7 38.32 44 4640 x 4720 x 5820 6954
29.80/25.73 20.4/15.8 883.38 291.52 24.4/23.8 13.7/13.7 42.17 39 4580 x 4930 x 6030 7180
29.80/25.70 20.4/15.8 901.26 297.42 24.2/23.6 13.7/13.7 43.03 42 4600 x 5180 x 6030 7605
Applied Systems
29.80/25.68 20.4/15.8 940.45 310.35 24.2/23.6 13.7/13.7 44.90 47 4600 x 5390 x 6030 7818
29.90/25.85 20.4/15.8 1003.85 331.27 24.4/23.8 13.7/13.7 47.93 44 4680 x 5600 x 6030 8174
l/s l/s kW kW °C °C °C °C
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel +
DWDI, Backward Curved Fan
°C °C kW kW °C °C mm kg
31.5/21.67 21/16 23.00 13.20 24.2/19.4 13.7/12.88 1550 x 1290 x 3740 807
32.5/22.2 21/16 38.90 21.80 25.2/20.1 13.7/12.85 1520 x 1500 x 3810 945
32.5/22.2 21/16 51.80 29.00 25.2/20.1 13.7/12.87 1700 x 1670 x 4040 1116
32.5/22.43 21/16 66.30 36.30 25.2/20.3 13.7/12.95 1840 x 1830 x 4080 1332
32.5/22.43 21/16 79.70 43.50 25.3/20.6 13.7/13.93 1960 x 1970 x 4450 1548
32.4/22.35 21/16 91.80 50.30 25.1/20.2 13.7/12.91 2310 x 2080 x 4450 1705
32.4/22.35 21/16 104.90 57.50 25.1/20.2 13.7/12.9 2380 x 2210 x 4710 1956
32.4/22.35 21/16 117.70 64.70 25.1/20.2 13.7/12.93 2620 x 2310 x 4710 2088
32.4/22.35 21/16 131.00 71.90 25.1/20.2 13.7/12.92 2680 x 2420 x 4780 2226
32.4/22.35 21/16 156.30 86.30 25.1/20.2 13.7/12.96 2660 x 2620 x 4910 2555
32.4/22.35 21/16 183.40 100.60 25.1/20.2 13.7/12.91 2990 x 2800 x 5210 2982
32.5/22.43 21/16 212.50 116.10 25.2/20.3 13.7/12.93 3180 x 2970 x 5360 3298
Applied Systems
QUICK SELECTION GUIDE 49
Fresh Air Handling Units with Dx Coil (34°C - 32°C) Winter
Selection
l/s l/s kW kW °C °C °C °C
FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Heat Recovery
Wheel + DX Cooling Coil + DWDI, Backward Curved Fan.
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + DWDI,
Backward Curved Fan.
°C °C kW kW °C °C mm kg
28.2/22.1 19.9/15.6 24.7 10.5 22.0/20.3 13.7/13.58 1440 x 1290 x 3650 767
28.3/22.0 19.8/15.6 36.7 16.1 22.2/20.2 13.7/13.5 1520 x 1500 x 3810 929
28.1/22.0 19.8/15.6 48.7 21.0 22.0/20.2 13.7/13.54 1820 x 1670 x 4070 1190
28.4/22.9 19.7/15.6 69.9 27.6 22.4/21.2 13.7/13.7 1940 x 1780 x 4150 1314
28.4/22.8 19.8/15.6 81.6 32.7 22.3/21.0 13.7/13.7 1960 x 1970 x 4220 1478
28.3/22.6 19.8/15.6 93.8 37.7 22.2/20.9 13.7/13.7 2310 x 2080 x 4670 1721
28.4/22.8 19.8/15.6 108.9 43.6 22.3/21.0 13.7/13.7 2380 x 2210 x 4580 1897
28.4/22.8 19.8/15.6 122.4 49.0 22.3/21.0 13.7/13.7 2620 x 2310 x 4620 2030
28.3/22.7 19.8/15.6 134.0 53.8 22.2/20.9 13.7/13.7 2580 x 2420 x 4690 2180
28.3/22.7 19.7/15.6 161.3 65.3 22.3/20.9 13.7/13.69 2660 x 2620 x 5010 2524
28.4/22.8 19.8/15.6 190.5 76.2 22.3/21.0 13.7/13.7 2990 x 2800 x 5160 2894
28.4/22.9 19.8/15.6 223.5 87.2 22.3/21.2 13.7/13.7 3080 x2970 x 5260 3209
Applied Systems
QUICK SELECTION GUIDE 51
Technical Information
Motor Efficiency Information Hygienic Units Pre-Requirements
Never specify IE1 (EFF2) motors. Any heat exchanger should not be wider than 300 mm and with access on both
On 22 July 2009, Commission Regulation (EC) No 640/2009 implementing Directive sides to allow cleaning. Keep the number of rows to max 6, however, if 8 rows comes
2005/32/EC states that in the EU, with the exception of some special applications, in 300 mm, then it is ok.
motors shall not be less efficient than the IE3 efficiency level as from 1 January 2015.
» T2/TB2 construction minimum
In detail: » Internal skin made of aluminum alloy or AISI 304 (preferable)
» IE2 by June 16, 2011 » On viewable surfaces like dampers or doors gasket must be rubber/EPDM (open
» IE3 by January 1, 2015 (for motors >=7.5 to 375 kW) and IE2 only in combination or closed cell gasket not acceptable)
with an adjustable speed drive » Only front release filter frame
» IE3 for all motors by January 1, 2017, (for motors from 0.75 to 375 kW). » Coil with aluminum or stainless steel frame. Fins preferably with ALUVER paint
» Coils with access on both side of the coil for cleaning
» Sloped drain pan made of stainless steel
DX Coil Capacity » Moisture eliminator made of stainless steel if required. Usually not recommended.
Total cooling capacity for AHU DX coil MUST be equal to the Condensing Unit » Sound attenuator stainless steel frame and film protection (melinex or similar to
cooling capacity. protect against fiber migration. Perforated plate also acceptable however not
recommendable as difficult to clean
AHU DX coil evaporation temperature MUST be equal to Condensing Unit saturated » Epoxy painted fan with paint strong enough to resist against abrasion. Typically a
suction temperature + 2°F. 4 layer epoxy pain. Only plug fans acceptable
» Sealant food grade
No. of AHU DX coil refrigerant circuits MUST be equal to the no. of Condensing Unit » No hollow sections allowed and if tubular frames are to be used they must be
refrigerant circuits. closed at the end with caps or welded
Temperature Rise
Electrical Power Input Calculation Temperature rise due to air compression (fan work):
Belt-Driven fans :
Electrical Power Input calculation = (Break power + 12% drive loss) / efficiency
EC fans :
Electrical Power Input is same as the shaft power. Where :
∆T : Fan Temperature rise
Ps : Fan brake shaft power
SFP Calculation μ : Fan efficiency
Cp : Specific heat capacity (1 for air)
q : air flow in m3/s
Where : p : density (1.2 kg/m3)
SFP: AHU Specific Power Input
For a fan 5.56 m3/s @ 14.6 kw break power at 72% fan efficiency the temperature rise
: Sum of all electric power input of the fan inside the AHU. So if you have 2 is approximately 0.6 °C
fan supply + 2 fan return your will have 4 power input
Temperature rise due motor heat rejection :
AF: This should be the AHU total supply air flow or if the unit is with supply and
return fans then the highest between the two
For a 18.5 kW motor at 5.53 m3/s at 85% motor efficiency the temperature rise is
approximately 0.41°C
Applied Systems
Coil Bypass Factor & Efficiency Formula
Coil Bypass Factor = (Air Outlet Temperature – T) / (Air Inlet Temperature – T)
T : Fluid Average Temperature
Fluid average temperature = (Inlet Temp + Outlet Temp)/2
∆T : Temperature difference, °C
∆h : Enthalpy difference, kJ/kg
∆w : Moisture concentration, g/kg dry air
Q : Air flow rate, m³/s
Benefits
» Fast track projects with critical deadlines and tight construction schedules
» Limited space facilities where you don’t want to sacrifice interior space to house a
central chiller plant
» MCP is an efficient and affordable alternative to the stick-built chiller central plant, suitable for
cost conscious projects
Daikin Advantages
Quality The MCP factory fabrication and assembly provide quality that exceeds outside field practices.
Paint finish on all structural steel and condenser water piping is standard. Components have
weather resistant finish that withstands 500-hour exposure to the salt spray test specified in
ASTM B 117.
Efficiency The Daikin chillers used in the MCP are industry leaders in efficiency. In addition, the MCP comes
standard with cooling tower VFDs for enhanced part load performance.
Simplicity Single source OEM supplier.
Sustainable HVAC solutions Daikin products are as good as their name. That's why Daikin offers a range of services
that offer increased efficiency, life cycle economy and guaranteed satisfaction, not to
mention peace of mind. At Daikin, we understand that HVAC is a big investment - not just
for Energy Saving for the initial installation, but also in terms of maintenance. Whether you need a technical
assistance, find the perfect service plan or optimise your system, Daikin is here for you.
Control solutions to optimise Energy Audit & Upgrade Turnkey solution for
energy Solution energy savings
» Chiller system manager » Targetted energy audits » Turnkey solution involving equipment
» Integration of AHU / Pumps » Upgrade of controls replacement with efficient products
» Remote KW monitoring & optimisation » Chiller retrofits » Improved ROI with system modernisation
» Remote software upgrades » Inverterisation involving chillers / DX / VRV, system control,
» PC workstation » Comply with latest regulations cooling towers, pumps, AHUs, FCUs
» Modernisation of controls » McQuay Daikin and other reputed brands
» Protecting environment & minimising carbon
footprint
» Customised solutions
Service
compressors Includes all preventive services and all breakdown labour
< 528 13.5 Reciprocating All 4.20 5.05 3.40 <264 4.513 5.588
264≤
< 528 4.45 5.25 3.40 Water cooled 4.542 5.724
CC<528
positive
Chillers 528 ≤ CC< 528≤
528 ≤ CC< 1055 15.0 Rotary screw 4.90 5.60 3.40 displacement 5.177 6.070
1055 CC<1055
Water Cooled
≥ 1055 kW 5.50 6.15 3.40 ≥1055 5.678 6.519
Size category EER EER IPLV Rated capacity EER EER Operability
Product Product
Btu/h Btu /h /W Btu /h /W Btu/h Btu/h /W Btu/h /W
category category
Single Split
Split system < 65000 9.5 6.6 ≤70000 11.5 8.28
system
65000 < CC ≤
Ducted split < 65000 9.5 6.6 11.2
135000
135000 < CC ≤
65000 ≤ CC <135000 9.5 6.6 11.0
Air cooled, 240000
yes
135000 ≤ CC Unitary 240000 <CC ≤
9.5 6.6 10.0
<240000 760000
240000 ≤ CC
9.5 6.6 > 760000 9.7
Air cooled, Split <760000
system and
≥ 760000 9.0 6.3 ≤65000 11.2
single package
65000 < CC ≤
11.2 (11 for H/P)
Multi split 135000
yes
(including VRV) 135000 < CC ≤
11.0 (10.6 for H/P)
240000
> 240000 10.0 (9.5 for H/P)
tons W/W W/W kW Btu/h /W
Reciprocating All 4.2 2.75 5.05 Air Cooled all 9.7 yes
263.7 < CC ≤
Screw and scroll 150 ≤ CC <300 4.9 3.2 Water cooled 16.0
527.4
screw
527.4 < CC ≤
≥ 300 5.6 3.6 17.7
1054.8
<150 6.0 > 1054.8 19.2
Split system ≤70000 9.5 6.84 Split system ≤70000 9.5 6.84
Authority Ministry of Electricity and Water Ministry of Electricity and Water QSASO
Ziad Awad Andrew Granville Mohamed Tarek Hajeh Mohamed Fathy Alazab Utpal Joshi
DX, VRV DX, VRV VRV, DX Consulting Sales DX, VRV
GSM: +971 52 945 4021 GSM: +971 50 899 2350 GSM: +971 52 741 8739 GSM: +974 55 576 619 GSM: +971 50 557 8464
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]
Khurram Nasir
Sharique Hasan Chiller & Air Side Ramesh Veluchamy
Chiller & Air Side GSM: +971 52 742 3900 Chiller & Air Side
GSM: +971 56 644 1905 E-mail: [email protected] GSM: +971 52 741 9428
E-mail: [email protected] E-mail: [email protected]