100% found this document useful (1 vote)
2K views

Daikin Quick Selection Guide

This document provides an overview and selection guide for Daikin's HVAC product range. It includes specifications and applications for split and VRV air conditioning systems, air handling units, air and water cooled chillers, and modular chiller plants. The guide also references Daikin's after sales service portfolio and includes technical information like HVAC formulae.

Uploaded by

Raghavendra NK
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views

Daikin Quick Selection Guide

This document provides an overview and selection guide for Daikin's HVAC product range. It includes specifications and applications for split and VRV air conditioning systems, air handling units, air and water cooled chillers, and modular chiller plants. The guide also references Daikin's after sales service portfolio and includes technical information like HVAC formulae.

Uploaded by

Raghavendra NK
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 64

Quick

Selection
Guide
High Ambient (46° OD)

Split Units VRV Rooftop Air Handling Units Air Cooled Chillers Water Cooled Chillers Modular Chiller Plant Service
Daikin world

Supermarket Factory
Technical

Hotel Store & Bank Industry


shop

Sport &
Home Office Leisure
The perfect working environment is essential for all
businesses. From supermarkets to offices, from public
buildings to hotels, from factories to data centers,
it is essential that the quality of the air is optimised at all
times – but no space is used in exactly the same way and
that calls for flexible, tailored and economic solutions.
Daikin, the innovation leader for more than 90 years, understands
this and its ‘total solution’ concept is built around customised
solutions for individual clients. Whether cooling, heating, ventilation,
air curtains or refrigeration with intelligent control systems.
Daikin has the units, the experience and the solution for
you. Learn all about our solutions for your business.
Our promise...
... is to ensure that customers can depend on Daikin
for the ultimate in comfort, so that they are free to
focus on their own working and home lives.
We promise to dedicate ourselves to technological excellence,
a design focus and the highest quality standards so that our
customers can trust and rely on the comfort we deliver.
Our promise to the planet is absolute. Our products are at the
forefront of low energy-usage and we will innovate to further reduce
the environmental impact of HVAC-R (Heating, Ventilation, Air
conditioning, Refrigeration) solutions. We lead where others follow.

We will continue our global leadership in HVAC-R solutions as our


specialist expertise in all market sectors combined with
90 years’ experience enable us to deliver added value in long-
lasting relationships based on trust, respect and credibility.

We promise to continue our forward-thinking ethos, treating


challenges as opportunities to produce ever-better solutions.
We will drive innovation and go the extra distance for our
customers and our company.
We will be smart and ready to do things differently.

We will deliver on these core values of our brand and enjoy


sustainable success with continued growth.
Table of contents Pages

Product Range 6

DX Systems 14
Split Units 16
Rooftop (Packaged Unit) 18

VRV Systems
VRV IV Outdoor Unit 20
Wall Mounted Series 22
Ducted Series 24
Cassette Series 25

Air Purifier 26

Applied Systems 28
Air Cooled Chillers 30
Water Cooled Centrifugal Chillers 33
Chilled Water Fan Coil Units 34
Air Handling Units 36
Technical Information 52

Modular Chiller Plant 54

After Sales Service Portfolio 56

Minimum EER for GCC 58

HVAC Formulae & Conversions 61


Product Range
Cooling Capacity Class TMBH (Nominal)
DX Indoor Unit Indoor Series Outdoor Series Product Picture
18 20 24 25 28 30 36 38 40 48 50

FTKM- PVMK RKM-PVMK

Wall Mounted FTNK-AV1K *(R / 9) RNK-AV1K *(R / 9) FTN-AV1 20/25

FTN-AV1K *(R / 9) RN-AV1K *(R / 9)


FTN-AV1 30

FDMRN-AV1K *(RE) RR-AV1K *(RE)


Ducted Split
FBQ-EVM RZR-MYM

*(R): Oman, Kuwait models, *(9): Bahrain, Qatar models, *(RE): UAE models  R-32  Refrigerant R-410A

Higher Capacity DX Cooling Capacity Class TMBH (Nominal)


Outdoor Series Product Picture
& Rooftop 60 90 120 150 180 210 240 270 300

Rooftop (Packaged Unit) UATQ-CGXY1

VRV IV Air Cooled (HP) Series Product Picture 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

RXYTQ-T7YF (VRV IV)                

Air Cooled Heat Pump


RXYSQ-TMY1B
(VRV-IV S Large)

VRV IV
Series Product Picture 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42
Water Cooled (HP)

Water Cooled Heat Pump


RWEYQ-T9Y1B              
& Heat Recovery

 Single Unit  Multi Combination

6 QUICK SELECTION GUIDE


Capacity Class
VRV IV Indoor Units Series Product Picture 15 20 25 32 40 50 63 71 80 100 125 140 200 250
Cooling Capacity (kW) 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 16 22.4 28

FXFQ-A
Ceiling Mounted Cas-
sette
FXZQ-A

FXDQ-A

FXSQ-A
Concealed Ceiling Unit
FXMQ-P7

FXMQ-MA/PVE

FXAQ-PVER1
Wall Mounted
FXAQ-PVE

FXHQ-A
Ceiling Suspended
FXUQ-A

FXLQ-P
Floor Standing
FXNQ-A

QUICK SELECTION GUIDE 7


Product Range
Cooling Capacity, TR (Nominal), CHW in/out 12/7°C and Ambient 35°C
Air Cooled Chillers Product Picture
50 100 150 200 250 300 350 400 450 500 550 600

EWAQ-E/F/G (Scroll) 20-192 TR

EWAD - E /D (Screw) 28-176 TR

EWAD-C (Screw) 217-577 TR

EWAD-M 219-423 TR

EWAD-MZ
103-322 TR

Water Cooled Cooling Capacity, TR (Nominal), CHW in/out 12/7°C, CW in: 29.4°C, CW Flow 3 GPM/TR
Product Picture
Chillers - Screw 50 100 150 200 250 300 350 400 450 500 550 600 650 750

EWWD-G 46-171 TR

EWWD-I 95-430 TR

EWWQ-B 108-617 TR

EWWD-VZ
127 - 588 TR

 Refrigerant R-134A  Refrigerant R-410A

8 QUICK SELECTION GUIDE


MZ Chiller Series
Premium Efficiency Range

Designed for High Ambient conditions


New generation of Daikin inverter screw
compressors

Refrigerant cooled inverter

VVR (Variable Volume Ratio) for optimum


efficiency at all ambient conditions 50 - 617 TR 200 - 3000 TR 100 - 650 TR Modular
Water Cooled Screw Water Cooled Magnetic Bearing Chiller Plants (MCP)
Centrifugal Oil-free Compressor
10% at full load, 30% at part load, better
efficiency at AHRI conditions

TOP CLASS EFFICIENCY

QUICK SELECTION GUIDE 9


Product Range
Water Cooled Cooling Capacity, TR (Nominal), CHW in/out 12/7°C, CW in: 29.4°C, CW Flow 3 GPM/TR
Product Picture
Centrifugal Chillers 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200

WMC / WME
(Magnetic Bearing)
100-650 TR

WSC 200-1250 TR

WTC 1200-1600 TR

WDC 400-2500 TR

WCC1200-2700 TR

WCT 2800-3000 TR

 Refrigerant R-134A

10 QUICK SELECTION GUIDE


The Highest Efficiency for District Cooling Solutions
WCT series - 3000TR Modular
Chiller Plant
Water-cooled 2-stage dual
compressor centrifugal chiller
Factory packaged cooling solution
200TR - 6000 TR

Japanese quality, engineering & construction


Single source responsibility
Optimized efficiency solution
Premium efficiency as low as Highest capacity with smallest
Expandable & flexible design
0.62 kW/TR footprint (70TR/m)
Plug & play solution
Lowest noise and vibration Built-in redundancy
Reduced footprint

R-134a

QUICK SELECTION GUIDE 11


PRODUCTS OVERVIEW
kW
Cooling Capacity
0 5 10 15 20 25 30 35 40

Product Range FWW-L

FWF-C
2/3/4/5/6

2/4/5

Chilled Water Fan Coil Units Product Picture CFM 200 300 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 2500 3000 4000 4600
FWK-E/
FWKE-E/ 5/6/8/9/11/13
FWW-DA FWKE-EH

FWE-E 5/6/7/8/10/12

FWW-C / F / H
FWE-D 7/9/13

FUW FWC-C 3/4/6/7/9/11/12/14/16

2/2.5/3.5
FWC-FD FWC-FD /4/5/7/8

FUD-B 20/25/30/40
FUD

FWE

Air Handing Units Product Picture CFM 300 650 1000 5000 10000 15000 20000 25000 30000 35000 40000 50000 53000 60000 70000 80000 83000

D-AHU 2

DDM-AHU

 Refrigerant R-410A

12 QUICK SELECTION GUIDE


Ceiling Concealed Unit
for District Cooling
Applications
FWW-DA

» Centrifugal Impeller » Washeable aluminum filters


» High-efficiency motor » ESP up to 100 Pa at medium speed
» High-efficiency heat exchanger » Low noise

QUICK SELECTION GUIDE 13


14 QUICK SELECTION GUIDE
DX Systems
Why choose FTKM Series

DX Systems
Daikin offers the best available technologies for

a Daikin the ultimate cooling comfort

» Inverter

split system?
» Powerful cooling performance, capacity and efficiency,
regardless of the outside temperature

The newly developed Daikin split wall is the


only split in the market that can provide as
much cooling capacity at 46ºC than at 35ºC
» The ideal solution for each application to the wide
range of available products both for cooling » Superior and efficient cooling comfort, all the year round
and heating
» Quick cooling up to 1.5 times faster than a traditional
» Low energy bills, thanks to high efficiencies and system, even under high ambient conditions
energy saving features such as intelligent eye and
weekly timer » Super quiet operation

» Perfect comfort: whisper quiet sound level &


perfect airflow pattern
» R-32 Refrigerant
» By using R-32 refrigerant on split A/C, GWP
effect can be reduced to 70% vs R-22

» Intelligent Eye
» Daikin further enhances efficiency while
keeping comfort optimal by offering smart
technology like intelligent eye, which is able
to adjust the room temperature based on the
occupancy.

QUICK SELECTION GUIDE 15


DX Systems
Nominal Actual Cooling Capacity
Air Flow (Medium) PI kW
Type Ref Model Image Indoor Outdoor Capacity at 46°C OD
(T3)
TR T.kW S.kW CFM L/S

FTKM18PVMK RKM18PVMK 1.50 4.61 4.16 583 275 1.57


Wall Mounted
R-32 FTKM24PVMK RKM24PVMK 2.00 6.15 5.00 625 295 2.19
Swing

BEST AVAILABLE TECHNOLOGY FTKM28PVMK RKM28PVMK 2.33 7.18 5.71 727 343 2.68

Wall Mounted FTNK20AV1K (R / 9) RNK20AV1K (R / 9) 1.50 3.66 3.20 474 224 1.91
(Non-Inverter)
R-410A
Premium
Rotary FTNK25AV1K (R / 9) RNK25AV1K (R / 9) 2.00 4.70 4.00 537 267 2.51

FTN20AV1K (R) (9) RN20AV1K (R / 9) 1.50 3.66 3.20 474 224 1.91

Wall Mounted FTN-AV1 20/25


FTN25AV1K (R / 9) RN25AV1K (R / 9) 2.00 4.70 4.00 537 267 2.51
FTN-AV1 20/25

(Non-Inverter) R-410A
Rotary
FTN30AV1K (R) RN30AV1K (R) 2.33 6.11 6.11 760 359 3.28

FTN-AV1 30

FTN-AV1 30

» Nominal Conditions (T1): 35 °C ambient and on coil of 27/19 DB/WB °C » Piping Limitation: Wall Mounted
» Actual Conditions: 46 °C ambient and on coil of 24/16 DB/WB °C at medium speed
» All units up to 3TR nominal capacity are 220-240V/1Ph/50Hz and above are 380-415V/3Ph/50Hz
» (R): Oman / Kuwait models
» (9): Bahrain / Qatar models

16 QUICK SELECTION GUIDE


DX Systems
Sound PR
EER ESP Pipe Size (Inch) Indoor Dimension (mm) Weight Outdoor Dimension (mm) Weight
(MED)
W/W Btu/W Pa Liquid Gas dBA W D H kg W D H kg

3.91 13.35 - 1/4" 1/2" 42 1050 259 340 15 930 350 695 46

3.72 12.70 - 1/4" 1/2" 45 1050 259 340 15 930 350 695 49

3.55 12.12 - 1/4" 5/8" 49 1200 259 340 18 930 350 695 49

3.23 11.04 - 1/4" 1/2" 39 1172 242 320 14 855 328 651 49

3.28 11.21 - 1/4" 5/8" 43 1172 242 320 14 855 328 753 57

3.23 11.04 - 1/4" 1/2" 39 1124 237 310 14 855 328 651 49

3.28 11.21 - 1/4" 5/8" 43 1124 237 310 14 855 328 753 57

2.88 9.84 - 3/8" 5/8" 46 1289 240 310 16 1030 400 852 77

Model G-mark ESMA QCC QSASO EWA MEW


FTKM-PVMK
FTNK-AV1K (R / 9)
FTN-AV1K (R / 9)

QUICK SELECTION GUIDE 17


DX Systems
Nominal Actual Cooling Capacity
Air Flow (Medium) PI kW
Type Ref Model Image Indoor Outdoor Capacity at 46°C OD
(T3)
TR T.kW S.kW CFM L/S
FDMRN20AV1K RR20AV1K *(RE) 1.50 3.79 3.3 618 292 1.55
FDMRN25AV1K RR25AV1K *(RE) 1.96 4.96 4.32 641 302 2.28
Ducted Split FDMRN30AV1K RR30AV1K *(RE) 2.33 6.53 5.68 793 374 2.94
(Non-Inverter) FDMRN36AV1K RR36AV1K 3.00 7.71 6.71 1378 650 3.46
R-410A
FDMRN36AV1K RR36AY1K 3.00 7.84 6.82 1378 650 3.48
FDMRN50AV1K RR50AY1K 3.94 10.63 9.25 1454 686 4.9

Ducted Split
FBQ48EVM RZR48MYM 3.1 8.78 8.39 1378 650 3.5

» Nominal Conditions (T1): 35 °C ambient and on coil of 27/19 DB/WB °C


» Actual Conditions: 46 °C ambient and on coil of 24/16 DB/WB °C at medium speed
» All units up to 3TR nominal capacity are 220-240V/1Ph/50Hz and above are 380-415V/3Ph/50Hz
» Piping Limitation: Ducted Split
» *(RE): UAE models

Nominal Actual Cooling Capacity @


Air Flow PI kW
Type Ref Model Image Indoor Outdoor Capacity 46°C OD
(T3)
TR T.kW S.kW CFM L/S
UATQ60CGXY1 5.08 13.82 12.92 2000 944 5.53
UATQ90CGXY1 7.50 20.55 19.22 2800 1322 8.41
UATQ120CGXY1 10.12 27.57 27.57 4400 2077 11.13
Rooftop UATQ150CGXY1 12.50 34.42 31.37 5000 2360 14.14
R-410A
(Packaged Unit) UATQ180CGXY1 15.08 41.63 41.63 7000 3304 16.95
UATQ210CGXY1 17.50 49.08 47.63 7600 3588 19.45
UATQ240CGXY1 20.00 55.51 52.56 8000 3776 22.29
UATQ300CGXY1 25.00 68.86 61.94 9000 4720 28.5
» Nominal Conditions (T1): 35 °C ambient and on coil of 27/19 DB/WB °C » Actual Conditions: 46 °C ambient and on coil of 24/16 DB/WB °C » All units are 380-415V/3Ph/50Hz

18 QUICK SELECTION GUIDE


DX Systems
Sound PR
EER (T1) ESP Pipe Size (Inch) Indoor Dimension (mm) Weight Outdoor Dimension (mm) Weight
(MED)
W/W Btu/W Pa Liquid Gas dBA W D H kg W D H kg
3.49 11.92 40 1/4" 1/2" 39 1137 388 261 26 855 328 753 47
3.44 11.75 40 1/4" 5/8" 35 1030 541 378 44 855 328 753 51
3.49 11.92 40 3/8" 5/8" 35 1030 541 378 44 1030 400 852 75
3.56 12.15 50 3/8" 5/8" 42 1287 541 378 50 1030 400 852 92
3.59 12.26 50 3/8" 5/8" 42 1287 541 378 50 1030 400 852 91
3.41 11.65 50 3/8" 5/8" 44 1487 541 378 56 1030 400 852 89

3.53 12.04 50 3/8 5/8 - 1400 700 300 46 1170 320 900 101

Model G-mark ESMA QCC QSASO EWA MEW


FDMRN-AV1K (R)
FBQ-EVM
UATQ-CGXY1

EER ESP Pipe Size (Inch) Sound PR Indoor Dimension (mm) Weight Outdoor Dimension (mm) Weight

W/W Btu/W Pa Liquid Gas dBA W D H kg W D H kg


3.96 13.51 50-500 - - 61 - - - - 1280 1520 1150 350
3.66 12.49 50-500 - - 62 - - - - 1280 1520 1350 380
4.06 13.86 50-500 - - 65 - - - - 1965 1630 1390 590
3.66 12.50 50-500 - - 67 - - - - 1965 1630 1390 650
3.60 12.28 50-500 - - 68 - - - - 1965 1905 1690 840
3.51 12.00 50-600 - - 69 - - - - 2410 2030 1650 930
3.40 11.60 50-600 - - 70 - - - - 2410 2030 1650 940
3.40 11.60 50-600 - - 72 - - - - 2410 2030 1750 1090

QUICK SELECTION GUIDE 19


VRV IV =
3 revolutionary
standards
› Variable refrigerant temperature
› Refrigerant-cooled PCB Simplified servicing

› VRV configurator

+ VRV IV core
technologies
› Newly developed inverter compressor
› 4 sided condenser coil
› Outer rotor DC Motor

+ Total Building
Solution
› Indoor line-up
› Fresh air
› Controls

20 QUICK SELECTION GUIDE


What does a VRV IV
installation mean to you?
See how you can benefit from Daikin’s highly flexible and efficient product range.

VRV IV Systems
Consultants » Technical design support
Daikin’s VRV IV technology maximises » Ecological design meets and exceeds legal requirements
flexibility and leads the way in customisation » Maximum flexibility to meet customer requirements
to match individual building requirements in » Advance software tools assist with system design
comfort and energy, with reduced running » Complies with ESMA UAE regulations
costs. » Complies with MEW-Kuwait regulations
» Complies with SASO Saudi regulations
» Complies with QCC AD-UAE regulations

Building owners » Up to 40% energy consumption saving over


VRV IV is the ultimate in customised comfort conventional AC systems
and intelligent control tailored to your » Single point of contact for the design and
individual needs and to maximise energy maintenance of your climate system
efficiency. » Integrated system, combining air conditioning,
ventilation, etc. allow maximum energy efficiency
» Multiple systems can be managed in exactly the
same way for key accounts
» Dedicated after-sales service to ensure fast on-site
support

Installers » Simplified and time-saving commissioning with VRV


Daikin VRV IV sets the standard with configurator
state-of-art technology and time-saving » Wide range of outdoor units (up to 48HP)
commissioning and servicing. » One supplier = one point of contact
» Maximum flexibility to meet customer requirements
» Customised training to maximise expertise

QUICK SELECTION GUIDE 21


Outdoor Units
ECAS

Nom Capacity Power COP COP (ESMA )


Length Width Height Weight Combination
Capacity at 46°C Input (Eurovent) (AHRI1230:2010)
Models
kW at No of
TR at 35°C kW at 35°C at 46°C mm mm mm kg Models
46°C Modules
RXYTQ8T7YF 6.4 20.2 6.57 4.58 3.07 930 765 1680 188 RXYTQ8TYF 1
RXYTQ10T7YF 8.0 25.2 8.29 4.81 3.04 1240 765 1680 236 RXYTQ10TYF 1
RXYTQ12T7YF 9.5 28.5 8.64 4.13 3.30 1240 765 1680 236 RXYTQ12TYF 1
RXYTQ14T7YF 11.4 32 10.17 3.70 3.15 1240 765 1680 298 RXYTQ14TYF 1
RXYTQ16T7YF 12.8 35.1 11.63 3.52 3.02 1240 765 1680 298 RXYTQ16TYF 1
RXYTQ18T7YF 14.3 45.4 14.86 4.71 3.06 1240 + 930* 765 1680 424 RXYTQ10 + 8* 2
RXYTQ20T7YF 15.9 48.7 15.21 4.30 3.20 1240 + 930* 765 1680 424 RXYTQ12 + 8 2
RXYTQ22T7YF 17.5 53.7 16.93 4.41 3.17 1240 + 1240* 765 1680 472 RXYTQ12 + 10 2
RXYTQ24T7YF 19.1 57 17.28 4.13 3.30 1240 + 1240* 765 1680 472 RXYTQ12 + 12 2
RXYTQ26T7YF 20.9 60.5 18.81 3.89 3.22 1240 + 1240* 765 1680 534 RXYTQ14 + 12 2
RXYTQ28T7YF 22.3 63.6 20.27 3.75 3.14 1240 + 1240* 765 1680 534 RXYTQ16 + 12 2
RXYTQ30T7YF 24.2 67.1 21.8 3.60 3.08 1240 + 1240* 765 1680 596 RXYTQ16 + 14 2
RXYTQ32T7YF 25.6 70.2 23.26 3.52 3.02 1240 + 1240* 765 1680 596 RXYTQ16 + 16 2
RXYTQ34T7YF 27.0 82.2 25.57 4.31 3.21 1240 + 1240 + 1240* 765 1680 708 RXYTQ12+12+10 3
RXYTQ36T7YF 28.6 85.5 25.92 4.13 3.30 1240 + 1240 + 1240* 765 1680 708 RXYTQ12+12+12 3
RXYTQ38T7YF 30.4 89 27.45 3.96 3.24 1240 + 1240 + 1240* 765 1680 770 RXYTQ14+12+12 3
RXYTQ40T7YF 32.3 92.5 28.98 3.82 3.19 1240 + 1240 + 1240* 765 1680 832 RXYTQ14+14+12 3
RXYTQ42T7YF 33.6 95.4 31.55 3.76 3.02 1240 + 1240 + 1240* 765 1680 832 RXYTQ16+16+10 3
RXYTQ44T7YF 35.1 98.7 31.9 3.66 3.09 1240 + 1240 + 1240* 765 1680 832 RXYTQ16+16+12 3
RXYTQ46T7YF 37.0 102.2 33.43 3.57 3.06 1240 + 1240 + 1240* 765 1680 894 RXYTQ16+16+14 3
RXYTQ48T7YF 38.4 105.3 34.89 3.52 3.02 1240 + 1240 + 1240* 765 1680 894 RXYTQ16+16+16* 3

* Standard combination, however, free combination of outdoor models allowed

22 QUICK SELECTION GUIDE


Large ECAS

VRV IV Systems
Nom Power Input COP COP (ESMA)
Capacity Length Width Height Weight Combination
Capacity (ESMA) (Eurovent) ISO15042:2011
Models
TR at kW at No of
kW at 46°C at 35°C at 46°C mm mm mm kg Models
35°C 46°C Modules
RXYSQ8TMY1B 6.4 16.22 5.75 3.66 2.82 320 940 1430 144 RXYSQ8TY1 1
RXYSQ10TMY1B 8.0 19.72 7.04 3.40 2.80 320 940 1430 178 RXYSQ10TY1 1
RXYSQ12TMY1B 9.5 22.51 8.17 3.30 2.76 460 940 1815 180 RXYSQ12TY1 1

COP Operation Range


Nom Capacity Power Input Length Width Height Weight (kg)
(Nom) (Cooling) °CDB
Models
Packed
TR at 35°C kW at 30°C at 20°C mm mm mm unit Min Max
Unit
RWEYQ8T9Y1B 6.4 (1) 3.5 (1) 6.5 (2) 560 767 980 190 201 10 45
RWEYQ10T9Y1B 8.0 (1) 4.9 (1) 6.4 (2) 560 767 980 190 201 10 45
RWEYQ12T9Y1B 9.5 (1) 6.0 (1) 6.10 (2) 560 767 980 192 202 10 45
RWEYQ14T9Y1B 11.4 (1) 7.9 (1) 5.37 (2) 560 767 980 192 202 10 45

» Indoor temperature : 27°CDB, 19°CWB; outdoor temperature : 35°CDB, 24°CWB


» Indoor temperature : 20°CDB, 15°CWB; outdoor temperature : 7°CDB, 6°CWB
» In accordance with EN/IEC 61000-3-12, it may be necessary to consult the distribution network operator to ensure that the equipment is connected only to a supply wih Ssc ≥ minimum Ssc value

QUICK SELECTION GUIDE 23


VRV Indoor Units
Capacity* Power Dimensions
Wall Series Ducted at 27°C / 19°C WB nominal at 24°C / 17°C WB Input
Air Flow
Length Depth Height
Sound Weight

Models
FXAQ-PVE TC
kW
TC
MBH
SC
(kW)
SC
(MBH)
TC kW
TC
MBH
SC
(kW)
SC
(MBH)
kW cfm L/s mm mm mm dBA kg

FXAQ20PVE 2.2 7.5 1.9 6.5 2 6.8 1.7 5.8 0.019 275 130 795 238 290 29 11
FXAQ25PVE 2.8 9.6 2.2 7.5 2.5 8.5 2.0 6.8 0.028 283 133 795 238 290 29 11
FXAQ32PVE 3.6 12.3 2.7 9.2 3.2 10.9 2.4 8.2 0.03 318 150 795 238 290 29 11
FXAQ40PVER1 4.5 15.4 3.5 11.9 3.9 13.3 3.1 10.6 0.020 424 200 1050 238 290 34 14
FXAQ50PVER1 5.6 19.1 4.2 14.3 4.9 16.7 3.8 13.0 0.033 530 250 1050 238 290 36 14
FXAQ63PVER1 7.1 24.2 5.3 18.1 6.2 21.2 4.7 16.0 0.050 671 317 1050 238 290 39 14
*Actual capacity depends only on outdoor unit.

Medium Static Capacity


Power
Input
Air Flow ESP Dimensions
Sound Weight
Ducted Series Ducted
at 27°C / 19°C WB nominal at 24°C / 17°C WB
Nom /
Width Depth Height
Models High
FXSQ-A TC TC SC SC TC TC SC SC
kW cfm L/s
Pa mm mm mm dBA kg
kW MBH (kW) MBH kW MBH (kW) MBH
FXSQ20A 2.2 7.5 1.6 5.5 2 6.8 1.5 5.1 0.041 318 150 30 / 150 550 800 245 28 24
FXSQ25A 2.8 9.6 2.0 6.8 2.5 8.5 1.8 6.1 0.041 318 150 30 / 150 550 800 245 28 24
FXSQ32A 3.6 12.3 2.6 8.9 3.2 10.9 2.4 8.2 0.045 335 158 30 / 150 550 800 245 29 24
FXSQ40A 4.5 15.4 3.3 11.3 3.9 13.3 3.0 10.2 0.092 530 250 30 / 150 700 800 245 32 28
FXSQ50A 5.6 19.1 4.1 14.0 4.9 16.7 3.7 12.6 0.095 537 253 30 / 150 700 800 245 32 29
FXSQ63A 7.1 24.2 5.2 17.7 6.2 21.2 4.6 15.7 0.095 742 350 30 / 150 1000 800 245 30 36
FXSQ80A 9 30.7 6.5 22.2 7.8 26.6 5.8 19.8 0.121 812 383 40 / 150 1000 800 245 32 36
FXSQ100A 11.2 38.2 8.3 28.3 9.8 33.4 7.4 25.2 0.157 1130 533 40 / 150 1400 800 245 34 46
FXSQ125A 14 47.8 10.2 34.8 12.2 41.6 9.1 31.1 0.214 1271 600 50 / 150 1400 800 245 36 47
FXSQ140A 16 54.6 11.7 39.9 14 47.8 10.5 35.8 0.243 1377 650 50 / 150 1550 800 245 38 51
Daikin pump standard

24 QUICK SELECTION GUIDE


Power
High Static Capacity
Input
Air Flow ESP Dimensions
Sound Weight
Ducted at 27°C / 19°C WB - Nom-
Ducted Series Models nominal
at 24°C / 17°C WB
High
Length Width Height
kW cfm L/s

VRV IV Systems
FXMQ-P/MA TC
kW
TC
MBH
SC
kW
SC
MBH
TC
kW
TC
MBH
SC
kW
SC
MBH
Pa mm mm mm dBA kg

FXMQ50P 5.6 19.1 4.6 15.7 4.9 16.7 4.1 14.0 0.11 636 300 100-200 1000 700 300 39 42
FXMQ63P 7.1 24.2 5.5 18.8 6.2 21.2 5.0 17.1 0.12 689 325 100-200 1000 700 300 40 42
FXMQ80P 9 30.7 7.0 23.9 7.8 26.6 6.3 21.5 0.171 883 417 100-200 1000 700 300 41 42
FXMQ100P 11.2 38.2 8.5 29.0 9.8 33.4 7.5 25.6 0.176 1130 533 100-200 1400 700 300 41 54
FXMQ125P 14 47.8 10.5 35.8 12.2 41.6 9.4 32.1 0.241 1377 650 100-200 1400 700 300 44 54
FXMQ140PVE* 16 54.6 12.0 40.9 14 47.8 10.7 36.5 0.461 1624 767 100-200 1400 700 300 45 47
FXMQ200MA** 22.4 76.4 16.8 57.3 19.5 66.5 15.1 51.5 1.3 2048 967 132-221 1380 1100 470 48 137
FXMQ250MA** 28 95.5 20.9 71.3 24.4 83.3 18.8 64.1 1.5 2543 1200 191-270 1380 1100 470 48 137
*Air filter & drain pump option
** Air filter option

Cassette Series Capacity*


Power
Air Flow Dimensions Sound Weight
Input
FXFQ-A Cassette Models at 27°C / 19°C WB - nominal at 24°C / 17°C WB Length Depth Height
TC SC SC TC TC SC SC kW cfm L/s dBA kg
TC kW mm mm mm
MBH kW MBH kW MBH kW MBH
FXFQ20A 2.2 7.5 1.8 6.1 2 6.8 1.6 5.5 0.038 441 208 840 840 204 29 19
FXFQ25A 2.8 9.6 2.1 7.2 2.5 0.7 1.9 6.5 0.038 441 208 840 840 204 29 19
FXFQ32A 3.6 12.3 2.8 9.6 3.2 0.9 2.6 8.9 0.038 441 208 840 840 204 29 19
FXFQ40A 4.5 15.4 3.4 11.6 3.9 1.1 3.0 10.2 0.038 477 225 840 840 204 31 20
FXFQ50A 5.6 19.1 4.1 14.0 4.9 1.4 3.7 12.6 0.053 530 250 840 840 204 31 21
FXFQ63A 7.1 24.2 5.2 17.7 6.2 1.8 4.7 16.0 0.061 583 275 840 840 204 33 21
FXFQ80A 9 30.7 6.5 22.2 7.8 2.2 5.9 20.1 0.092 805 380 840 840 246 34 24
FXFQ100A 11.2 38.2 7.8 26.6 9.8 2.8 7.1 24.2 0.115 936 442 840 840 246 37 24
FXFQ125A 14 47.8 9.8 33.4 12.2 3.5 8.8 30.0 0.186 1165 550 840 840 288 41 26
*Actual capacity depends only on outdoor unit.

QUICK SELECTION GUIDE 25


MC70L MC70L
The streamer technology air purifier, a blend of Wha
The streamer technologynewair purifier, a blend
technology, improved Whatand
of performance, is the
ultraDaikin stre
new technology, improved
quiet performance, and ultrato care for you by
operation, is designed “Strea
quiet operation, is designed to care for you
unobtrusively providing by “Streamer
to produceDischarge” isinawh typ
unobtrusively providing to produce in which
a healthy home environment. Purified air improves high speed electro
decom
a healthy home environment. Purifiedofaircomfort
the perception improves decomposition
and, by removing and are generaelimin
the perception of comfort and, by
destroying removing and
contaminants eliminate
and odours, bacteria and
the streamer chemmo
destroying contaminants and odours, the streamer chemical
technology air purifier also plays an essential role substances and
to stana
technology air purifierfor
also plays an essential role to
those who suffer from asthma or allergies. standard plasma discharg
the di
for those who suffer from
Theseasthma
effortsor allergies.
place the discharge
the streamer technology air range ofwider Daik
These efforts place thepurifier
streamer technology air wider,
among the best residential air purifiers onwhich makes it easier
with o
purifier among the besttheresidential air purifiers on
market today. with oxygen and nitrogen speed in
the market today. speed electrons to be over genea
over a wide area, which resu
decom
Three times purification, decomposition speed with ti
that
Three times purification,
a good deed for your health with the same electrical pow
Disch
a good deed for your health Discharge technologygener has p
Pollen, dust and pet hair are just some generating
of the high speedconsid elec
Pollen, dust and pet hair are just some of the considered
potential causes of allergies, asthma and respiratory difficult up to no
potential causes of allergies, asthma and respiratory
problems. A Daikin air purifier cleans the air and
problems. A Daikin airrelieves
purifier you
cleans thethese
from air andtroubles, thanks to: Main
relieves you from these troubles, thanks to: Main specifications
• allergen removal Daikin
• allergen removal • virus and bacteria removal Daikin has already received
• virus and bacteria removal purifie
• odour removal purifiers: a British AllergyandFoth
• odour removal • dust removal and the TÜV Nord testour mark
• dust removal un
our units.




26 QUICK SELECTION GUIDE


4
2 Dust and pollen
Dust is captured.
Bacteria and
3 are absorbed
by the electrically
5 Odours and viruses are
nd of What is the Daikin streamer technology ? allergens Dust and pollen are charged filter kept under control
and ultra are removed electrically charged Electrostatic dust by photocatylist
u by
roduce
improves
“Streamer Discharge” is a type of plasma discharge
in which high speed electrons capable of oxidative
decomposition are generated. It has the ability to
You breathe 22,000 times a day.
Prefilter and then sent to
the filter
Plasma ionizer
collection filter
(front of pleated dust
collection filter)
Titanium apatite filter
(back of pleated dust
collection filter)
ving and eliminate bacteria and mould as well as hazardous
he streamer
tial role
rgies.
chemical substances and allergens, etc. Compared
to standard plasma discharge (glow discharge),
the discharge range of Daikin’s Streamer Discharge is
What do you take in?
gy air wider, which makes it easier for electrons to collide
ifiers on with oxygen and nitrogen in the air. This enables high
speed electrons to be generated three dimensionally •Main features
Stylish design of the Air Purifier:
over a wide area, which results in an oxidative
decomposition speed that is over 1,000 times greater Removes
• Improved 99% virus and bacteria
performance
with the same electrical power. Daikin’s Streamer
Discharge technology has proven successful in stably Eliminates
• Unprecedented dust and sand particles
comfort

Air Purifier
generating high speed electrons, a feat that has been
the considered difficult up to now. Destroys
• Super quiet 99.6% of allergy
operation
espiratory
air and • Easy to Odours
maintain neutralization
o: Main specifications
• PortableUltra quiet operation (16dBA)
Daikin has already received great praise for its air
purifiers: a British Allergy Foundation seal of approval Portable (8.5 KG)
• No installation
and the TÜV Nord test mark confirm the efficiency of
our units. No need of installation
Easy maintenance
Indoor unit MC70L
Applicable room area Economical m² 46
Dimensions Unit HeightxWidthxDepth mm 576x403x241
Weight Unit kg 2 8.5
Casing Colour White
Fan Type Multi Blade Fan (Sirocco fan with shroud assembly)
Air flow rate Air Turbo/High/ m³/h
purifying Medium/Low/ 420/285/210/130/55
operation Silent

Sound pressure level Air purifying operation Turbo/High/Medium/Low/Silent dBA 48.0/39.0/32.0/24.0/16.0


Air purifying operation Power input Turbo/H/M/L/Silent kW 0.065/0.026/0.016/0.010/0.007
Deodorizing method Flash streamer / Titanium apatite photocatalytic filter / Deodorising catalyst
Bacteria filtering method Flash streamer / Titanium apatite photocatalytic filter
Dust collecting method Plasma ionizer / Electrostatic dust collection filter
Sign Item 01/02/03/04/05/06/07/08/09/10/11 Dust: 3 stages/Odour: 3 stages/Automatic operation (LL-H)/Airflow rate (LL/L/M/H)/Turbo mode (HH)/Anti-pollen mode/Sleep mode/Lock (Anti-
tamper)/Off timer (1.2.4h)/Maintenance: Filter replacement/Maintenance: Cleaning of ionization/streamer
Power supply Phase/Voltage V 1~/220-240/220-230

15
QUICK SELECTION GUIDE 27
Chillers
No matter how large your premises and whatever your air
Daikin chillers offer the ultimate in reliability and conditioning needs in climate control or process cooling and
heating, there is a system that has proved worthy in a multiplicity
flexibility — a reflection of the advanced technology
of situations - from industrial sites to retail warehouses, hotels and
inherent within them. Daikin chillers represent the sure department stores.

and safe route to a comfortable environment and a


The careful development of closely matched compressor/
process cooling solution that is clean and consistent. refrigerant combinations, has enabled Daikin to produce
complete range of chillers - genuinely optimised for use with fan
coil units and R-134A, R-407C and R-410A refrigerants.

Daikin chillers offer ultimate in flexibility and control - a reflection


of the advanced technology inherent within them. Unique in their
precision, power, low operating noise, easy maintenance and low
running costs, Daikin chillers represent the sure and safe route to
an indoor environment that is comfortable, clean and consistent.

As a manufacturer that makes its own refrigerant and


compressors, Daikin has total control at the production stage.
Daikin also offers a complete range of air handling units to
meet modern day requirements for better indoor air quality and
increased insulation standards.

It is this unique combination of advanced technology, experience


and reliability that makes Daikin the obvious choice and long-
term solution for the professional.

28 QUICK SELECTION GUIDE


Why choose Daikin chillers?
The simple answer is that, as the market leader, the performance of
our equipment is second to none. From the smallest chillers to the
very largest, our quality control and attention to detail is absolute. Our
systems have the most advanced technologies, deliver the highest
energy efficiencies and lowest running costs, and are the gold standard
for reliability and performance.

The widest and most flexible chiller portfolio


› From the smallest mini chiller for residential use to the largest chiller for district cooling
› Tailor-made solutions based on the most advanced technologies

Worldwide experience in chiller design and manufacturing


› World’s most advanced facilities for air conditioning research and development: Applied
Development Center in Minneapolis, Minnesota

Applied Systems
› In-house development and manufacturing of chiller main components (compressors, fans
condenser coils, software, etc.)

The highest efficiency for every installation


› The lowest total cost of ownership and fast payback time

Quality and reliability


› Daikin's integrated zero defect policy ensures quality of components and finished products
› Each Daikin chiller is factory run-tested and subjected to quality audit before shipment

QUICK SELECTION GUIDE 29


Air Cooled Chillers
Cooling Water Flow Dimensions Shipping Operation Sound pressure level
Models
Capacity (TR) Rate (LPS) ( H x Wx L ) mm Weight (kg) Weight (kg) at 1m in dB(A)
EWAD100E-SS 25.30 4.2 2273 x 1292 x 2165 1684 1699 73.5
EWAD120E-SS 30.10 5.1 2273 x 1292 x 2165 1684 1699 73.5
EWAD140E-SS 34.70 5.8 2273 x 1292 x 3065 1861 1881 73.7
EWAD160E-SS 41.00 6.8 2273 x 1292 x 3065 1861 1881 73.7
EWAD180E-SS 44.10 7.4 2273 x 1292 x 3965 2086 2116 73.9
EWAD210E-SS 53.80 9 2273 x 1292 x 3965 2086 2116 75.1
EWAD260E-SS 63.10 10.6 2223 x 2236 x 3070 2919 2963 75
EWAD310E-SS 74.80 12.5 2223 x 2236 x 3070 2919 2963 75.3
EWAD360E-SS 87.00 14.6 2223 x 2236 x 3070 2919 2963 75.3
EWAD410E-SS 93.30 15.7 2223 x 2236 x 3070 2919 2963 76

Cooling Water Flow Dimensions Shipping Operation Sound pressure level


Models
Capacity (TR) Rate (LPS) ( H x Wx L ) mm Weight (kg) Weight (kg) at 1m in dB(A)
EWAD250D-XS 64.80 10.9 2355 x 2234 x 3138 2905 3000 77.5
EWAD280D-XS 73.10 12.3 2355 x 2234 x 4040 3285 3400 77.5
EWAD300D-XS 79.90 13.4 2355 x 2234 x 4040 3285 3400 77.5
EWAD330D-XS 85.90 14.4 2355 x 2234 x 4040 3285 3400 77.5
EWAD350D-XS 92.20 15.4 2355 x 2234 x 4040 3240 3400 77.5
EWAD380D-XS 99.30 16.7 2355 x 2234 x 4040 3240 3400 79
EWAD400D-XS 106.10 17.8 2355 x 2234 x 4040 3240 3400 79
EWAD470D-XS 114.90 19.3 2355 x 2234 x 4040 3510 3780 79
EWAD520D-XS 134.00 22.5 2223 x 2234 x 4940 4670 4670 79
EWAD580D-XS 145.60 24.4 2223 x 2234 x 4940 4685 4685 79
EWAD620D-XS 157.00 26.4 2223 x 2234 x 4940 4685 4685 79
Cooling capacity is based on 46 °C ambient temperature, and water in/out at 7/12 °C
Refrigerant R-134A

30 QUICK SELECTION GUIDE


Cooling Water Flow Dimensions Shipping Operation Sound pressure level
Models
Capacity (TR) Rate (LPS) ( H x Wx L ) mm Weight (kg) Weight (kg) at 1m in dB(A)
EWAD760C-XS 193.70 32.5 2540 x 2285 x 6285 5990 6240 79.7
EWAD830C-XS 213.90 35.9 2540 x 2285 x 7185 6340 6580 79.7
EWAD890C-XS 227.50 38.2 2540 x 2285 x 7185 6360 6600 79.7
EWAD990C-XS 256.00 42.9 2540 x 2285 x 8085 7190 7600 80.2
EWADC10C-XS 272.80 45.7 2540 x 2285 x 8085 7470 7870 80.7
EWADC11C-XS 307.70 51.6 2540 x 2285 x 9885 8220 8610 80.3
EWADC12C-XS 327.60 55 2540 x 2285 x 9885 8240 8630 80.4
EWADC13C-XS 341.90 57.3 2540 x 2285 x 9885 8900 9890 80.4
EWADH14C-XS 357.20 59.9 2540 x 2285 x 9885 8900 9890 80.4
EWADH15C-XS 382.80 64.2 2540 x 2285 x 9885 8900 9890 80.4
EWADC16C-XS 407.00 68.3 2540 x 2285 x 12085 11570 12430 80.9
EWADC17C-XS 431.50 72.4 2540 x 2285 x 12985 11900 12760 80.8
EWADC18C-XS 453.60 76.1 2540 x 2285 x 13885 12260 13140 81
EWADC19C-XS 477.80 80.2 2540 x 2285 x 14785 12600 13470 81
EWADC20C-XS 490.00 82.2 2540 x 2285 x 14785 12600 13470 81

Applied Systems
EWADC21C-XS 501.70 84.2 2540 x 2285 x 14785 12600 13470 81
EWADC22C-XS 514.50 86.3 2540 x 2285 x 14785 12600 13470 81
Cooling capacity is based on 46 °C ambient temperature, and water in/out at 7/12 °C
Refrigerant R-134A

QUICK SELECTION GUIDE 31


Air Cooled Chillers
Cooling Water Flow Dimensions Shipping Operation Sound pressure level
Models
Capacity (TR) Rate (LPS) ( H x Wx L ) mm Weight (kg) Weight (kg) at 1m in dB(A)
EWAD380-MZS 108 16.7 2483 x 2258 x 4083 4044 4202 81
EWAD450-MZS 124 18.9 2483 x 2258 x 4083 4060 4224 80
EWAD495-MZS 138 21.0 2483 x 2258 x 4983 4317 4475 81
EWAD570-MZS 157 24.0 2483 x 2258 x 5883 4603 4761 82
EWAD610-MZS 169 25.6 2483 x 2258 x 5883 4780 5050 81
EWAD660-MZS 182 27.6 2483 x 2258 x 5883 4804 5059 83
EWAD700-MZS 194 29.2 2483 x 2258 x 6783 5074 5329 84
EWAD820-MZS 214 32.7 2483 x 2258 x 6783 6249 6532 83
EWAD900-MZS 232 35.4 2483 x 2258 x 6783 6147 6632 83
EWADC10-MZS 259 39.5 2483 x 2258 x 7783 6542 7027 83
EWADH10-MZS 274 41.8 2483 x 2258 x 8820 6897 7382 82
EWADH11-MZS 294 44.9 2483 x 2258 x 10461 8037 8490 83

Cooling Water Flow Dimensions Shipping Operation Sound pressure level


Models
Capacity (TR) Rate (LPS) ( H x Wx L ) mm Weight (kg) Weight (kg) at 1m in dB(A)
EWAD740M-XSB2 200.3 33.6 2482 x 2258 x 6783 6357 6676 81.7
EWAD820M-XSB2 217.1 36.4 2482 x 2258 x 6783 6357 6658 82.2
EWAD900M-XSB2 231.9 38.9 2482 x 2258 x 7783 6630 6931 81.8
EWADC10M-XSB2 259 43.5 2482 x 2258 x 7783 6936 7219 82.4
EWADH10M-XSB2 280.5 47.1 2482 x 2258 x 7783 7247 7530 82.6
EWADC12M-XSB2 314.5 52.8 2482 x 2258 x 8820 7669 8154 82.6
EWADC13M-XSB2 341.2 57.3 2482 x 2258 x 9720 7900 8385 82.7
EWADH13M-XSB2 355.7 59.7 2482 x 2258 x 10620 8218 8671 82.7
EWADC14M-XSB2 368.5 61.9 2482 x 2258 x 10620 8218 8671 82.8
EWADC15M-XSB2 381.3 64 2482 x 2258 x 11520 8536 8989 82.5
Performances are based on the following conditions: evaporator 12.2/6.7°C; ambient 46°C; unit at full load operation; operating fluid: water
Refrigerant R-134A

32 QUICK SELECTION GUIDE


Distinction Series For Reliability & High Efficiency

WSC 200 TR - 1250 TR WTC 1200 - 1600 TR WDC: 400 TR - 2500 TR WCC: 1200 TR - 2700 TR

» Daikin exclusive compressor design » Movable discharge diffuser for better unloading » NPLV of up to 0.33 kW/TR
» R-134A - No Phase-out Refrigerant » Dual Compressor option from 400 TR capacity » Virtually maintenance free operation
» Semi-hermetic Compressor » Touch screen control display as standard » AHRI-certified performance
» Gear driven impeller » AHRI certified performance

Applied Systems
WMC/WME 100 - 650 TR WCT 2800 - 3000 TR
» Oil free magnetic bearing compressor » Exclusive TWO stage compressor design
» Inverter driven DC brushless compressor » R-134A - No Phase-out Refrigerant
motor » Semi-hermetic compressor
» Semi hermetic design » Refrigerant cooled oil cooler
» Sustainable performance » Movable discharge diffuser for better
» Low sound levels unloading
» NPLV of up to 0.33 kW/TR » Dual Compressor Chiller
» Virtually maintenance free operation » Touch screen control display as standard
» AHRI-certified performance » AHRI-certified performance

QUICK SELECTION GUIDE 33


Ducted Chilled Water Fan Coil Units (District Cooling Applications)
Water Rated Sound
PRODUCTS OVERVIEWAir Flow Cooling Capacity
Water
flow
Pressure
Drop
Power
Input
Pressure
Level
Dimensions
Weight
Models Model Image
kW Total Sensible Length Depth Height
Cooling Capacity
0 CFM 10 l/s 15 35m /hr40 kPa kW db(A)
3
5 20
kW
25 30
kW mm mm mm kg
FWW02DA 176 83 1.59 1.25 0.15 3.19 0.055 41.5 675 529 243 19
FWW-L
FWW03DA 2/3/4/5/6
229 108 1.94 1.58 0.18 4.21 0.078 43 675 529 243 19
FWW04DA 328 155 2.85 2.29 0.27 10.17 0.098 43 825 529 243 24
FWW05DA 406 192 3.44 2.85 0.33 14.75 0.108 44 925 529 243 25
FWW06DA 455 215 4.19 3.34 0.4 7.3 0.133 46.5 995 529 243 28
FWF-C 2/4/5
FWW07DA 554 262 4.65 3.98 0.44 10.34 0.153 46.5 1095 529 243 31
FWW08DA 537 253 4.87 3.86 0.46 10.52 0.153 47.5 1095 529 243 31
FWW10DA 821 388 6.1 5.56 0.58 9.25 0.254 48 1425 529 243 43
FWK-E/
FWW12DA
FWKE-E/ 861 406 7.27 5.87 0.69 13.06 0.219 49.5 1525 529 243 48
5/6/8/9/11/13
FWKE-EH
FWW14DA 967 456 7.94 6.46 0.76 15.37 0.264 51 1525 529 243 48
FWW16DA 1094 517 8.95 7.33 0.85 13.28 0.4 51 1425 599 297 55
FWW18DA 1297 612 10.28 8.6 0.98 18.59 0.514 53 1525 599 297 58
FWW20DA
FWE-E 1611
5/6/7/8/10/12 760 12.63 10.72 1.2 19.31 0.609 56 1825 599 297 68
Above performance data is based on following conditions: » 220V/1ph/50Hz » Sound pressure measured at 1m in front of the unit and 1m below the vertical center line of the unit,
» Cooling : 24°C DB / 17°C WB and water inlet 5.5°C outlet 14.5°C » Dimensions are for the units with standard drain pan and tested in semi-anechoic room, with background sound pressure level: 11.5Db (a).
» Medium speed, 50 Pa ESP

FWE-D 7/9/13 Water Rated Sound


Water
Air Flow Cooling Capacity Pressure Power Pressure Dimensions
flow Weight
Models Model Image Drop Input Level
Total Sensible Length Depth Height
FWC-C CFM l/s m3/h kPa kW db(A)
3/4/6/7/9/11/12/14/16 kW kW mm mm mm kg
FWC02 FD 220 104 1.13 1.06 0.11 11.9 0.092 39 619 552 247 16
FWC03 FD 250 118 1.35 1.24 0.14 9.5 0.108 39 610 552 247 17
2/2.5/3.5
FWC04 FD 360 170 2.61 2.34 0.25 10.7 0.131 40 870 552 247 23
FWC-FD /4/5/7/8
FWC05 FD 440 208 3.43 2.69 0.32 25.8 0.151 41 870 552 247 24
FWC06 FD 550 260 3.88 3.21 0.36 12.1 0.192 44 1060 552 247 28
FWC08 FD 790 373 5.55 4.68 0.54 14.9 0.265 46 1390 552 247 38
FWC10 FD 910 429 5.78 5.15 0.54 10.5 0.321 47 1600 552 247 45
Above performanceFUD-B
data is based on following conditions: » 220V/1ph/50Hz 20/25/30/40 » Sound pressure level is tested with 2m length duct at the discharge air outlet and 1m
» Cooling : 24°C DB / 17°C WB and water inlet 5.5°C outlet 14.5°C » Dimensions are for the units with standard drain pan length of return air duct. Microphone position: 1.5m below the centre of unit
» Medium speed, 75 Pa ESP (only FWC02 FD model capacities are based on 73 Pa ESP)

34 QUICK SELECTION GUIDE


Ducted Chilled Water Fan Coil Units (Normal Chilled Water Applications)
Water Rated Sound
Water
Air Flow Cooling Capacity Pressure Power Pressure Dimensions
flow Weight
Models Model Image Drop Input Level
Total Sensible Length Depth Height
CFM l/s m3/h kPa kW db(A)
kW kW mm mm mm kg
FWW200F 156 74 1.50 1.17 0.26 1 0.045 35 714 556 251 22
FWW300F 216 102 1.92 1.55 0.33 2 0.06 36 884 556 251 27
FWW400F 297 140 2.84 2.17 0.49 4 0.071 41 1014 556 251 31
FWW600F 469 221 4.28 3.49 0.73 11 0.125 46 1214 556 251 36
FWW800F 654 309 5.32 4.54 0.91 4 0.193 47 1464 556 251 48
FWW1000F 673 318 5.84 4.80 1.00 4 0.189 48 1564 556 251 52
FWW1200F 896 423 7.50 6.38 1.29 8 0.237 48 1824 556 251 56
FWW1400F 1180 557 9.13 7.00 1.57 17 0.362 51.5 1200 670 345 53.5
FWW1600F 1392 657 10.83 8.96 1.86 17 0.451 52.5 1300 670 345 58
FWW1800F 1604 757 12.15 10.11 2.08 18 0.508 53 1450 670 345 61
Above performance data is based on following conditions: » 220V/1ph/50Hz
» Cooling : 24°C DB / 17°C WB and water inlet 7°C outlet 12°C » Sound pressure levels are tested in semi-anechoic room, with background level:15 db(A), microphone position of the measure-
» Medium speed, 75 Pa ESP ment point is 1m in front and 1m below the unit

Decorative Under Ceiling Chilled Water Fan Coil Units

Applied Systems
Water Rated Sound
Water
Air Flow Cooling Capacity Pressure Power Pressure Dimensions
flow Weight
Models Model Image Drop Input Level
Total Sensible Length Depth Height
CFM l/s m3/h kPa kW db(A)
kW kW mm mm mm kg
FWE06E 530 250 3.76 3.06 0.18 26.7 0.108 43 1090 630 212 27
FWE07D 690 326 5.41 4.13 0.26 31.3 0.121 50 1214 670 249 45
FWE07E 560 264 3.86 3.21 0.18 31.1 0.115 46 1090 630 212 27
FWE08E 750 354 4.86 4.14 0.23 17.4 0.157 47 1320 635 259 41
FWE10E 980 463 6.87 5.44 0.33 25.5 0.187 47 1538 635 259 46
FWE12E 1080 510 10.45 7.43 0.5 40 0.25 50 1786 635 259 53
FWE13D 1020 481 10.07 7.49 0.48 24.3 0.193 53 1714 670 249 70
Above performance data is based on following conditions: » 220V/1ph/50Hz
» Cooling : 24°C DB / 17°C WB and water inlet 7°C outlet 12°C » Sound pressure level is tested at microphone position 1m in front of the unit and 1m below the air discharge opening
» Medium speed, 0 Pa ESP

QUICK SELECTION GUIDE 35


Daikin air handling units, with their
plug-and-play design and inherent
flexibility, can be configured and
combined specifically to meet
the exact requirements of any
building, no matter what it is used
for or who is to work there. Our
systems are designed to be the
most environmentally friendly
and the most energy efficient in
the market, thus reducing their
ecological impact, while, at the
same time, keeping costs down
through the minimisation of energy
consumption.

When combined with the small

Air Handling Units


physical footprint of the system,
these features make our air
handling units ideal for all markets.

36 QUICK SELECTION GUIDE


Air Handling Units for District Cooling
Cooling Coil
Supply Motor Water
Total Sensible Leaving Air Water Height x Width x Length Weight
Models Airflow Power Pressure
Capacity Capacity Temperature Flow
Drop
l/s kW kW kW DB/WB (°C) l/s kPa mm kg
680x790 500 0.75 7.54 6.71 13/12.48 0.20 26 680 x 790 x 2050 197
800x870 750 1.10 11.13 10.13 13/12.55 0.30 15 800 x 870 x 2080 223
860x980 1000 1.50 14.59 13.42 13/12.63 0.39 24 860 x 980 x 2160 258
870x1140 1250 2.20 18.41 16.75 13/12.59 0.49 43 870 x 1140 x 2210 287
870x1310 1500 2.20 23.31 20.05 13/12.33 0.62 46 870 x 1310 x 2180 317
880x1480 1750 3.00 25.70 23.64 13/12.60 0.68 39 880 x 1480 x 2210 339
1000x1420 2000 3.00 29.56 26.90 13/12.57 0.78 48 1000 x 1420 x 2280 374
1110x1500 2500 4.00 36.79 33.48 13/12.59 0.98 43 1110 x 1500 x 2420 426
1180x1650 3000 5.50 43.92 40.41 13/12.62 1.20 36 1180 x 1650 x 2490 503
1360x1610 3500 5.50 51.34 47.23 13/12.61 1.36 35 1360 x 1610 x 2490 520
1480x1650 4000 7.50 58.60 53.91 13/12.61 1.55 35 1480 x 1650 x 2580 567
1490x1820 4500 7.50 66.26 60.30 13/12.59 1.76 48 1490 x 1820 x 2630 622
1490x1980 5000 7.50 73.01 67.17 13/12.63 1.94 28 1490 x 1980 x 2700 683

Applied Systems
1620x2140 6000 11.00 88.07 81.02 13/12.6 2.34 36 1610 x 2140 x 2990 897
1740x2260 7000 11.00 106.41 93.64 13/12.43 2.82 48 1740 x 2260 x 2990 948
1740x2540 8000 11.00 117.43 108.04 13/12.6 3.11 49 1740 x 2540 x 3210 1111
1870x2630 9000 15.00 132.44 120.52 13/12.59 3.51 40 1870 x 2630 x 3210 1177
2050x2620 10000 15.00 146.58 134.85 13/12.61 3.89 39 2050 x 2620 x 3210 1209
2090x2890 11000 18.50 161.92 147.35 13/12.59 4.29 46 2090 x 2890 x 3260 1444
2210x2940 12000 18.50 185.86 161.70 13/12.35 4.93 42 2210 x 2940 x 3370 1592

QUICK SELECTION GUIDE 37


Air Handling Units for District Cooling
Cooling Coil
Supply Motor Water
Total Sensible Leaving Air Water Height x Width x Length Weight
Models Airflow Power Pressure
Capacity Capacity Temperature Flow
Drop
l/s kW kW kW DB/WB (°C) l/s kPa mm kg
2220x3160 13000 22.00 189.49 174.33 13/12.64 5.03 35 2220 x 3160 x 3400 1642
2220x3380 14000 22.00 204.80 188.42 13/12.62 5.43 43 2220 x 3380 x 3400 1759
2290x3490 15000 22.00 219.85 202.26 13/12.61 5.83 47 2290 x 3490 x 3550 1844
2290x3700 16000 30.00 235.08 213.92 13/12.60 6.24 42 2290 x 3700 x 3550 1984
2300x3910 17000 30.00 250.15 227.64 13/12.59 6.63 49 2300 x 3910 x 3610 2096
2300x4120 18000 30.00 269.74 242.77 13/12.51 7.15 42 2300 x 4120 x 3720 2260
2420x4100 19000 30.00 284.51 256.06 13/12.51 7.55 42 2420 x 4100 x 3720 2289
2430x4300 20000 30.00 290.76 267.50 13/12.65 7.71 29 2430 x 4300 x 3690 2304
2430x4490 21000 37.00 305.86 281.39 13/12.64 8.11 33 2430 x 4490 x 4050 2489
2440x4690 22000 37.00 321.11 295.42 13/12.63 8.52 37 2440 x 4690 x 4050 2614
2440x4890 23000 2 x 18.5 336.94 309.98 13/12.61 8.94 42 2440 x 4890 x 3400 2354
2450x5130 24000 2 x 18.5 352.08 323.91 13/12.61 9.34 47 2450 x 5130 x 3400 2486
2450x5330 25000 2 x 18.5 367.15 337.78 13/12.60 9.74 44 2450 x 5330 x 3400 2533

AHUs include Prefilter (G4)+ Bag Filter (F7) + Cooling Coil + DWDI, Backward Curved Fan

Above performance data is based on following conditions:


» Cooling: Air on 24°C DB / 17°C WB and water inlet 5.5°C outlet 14.5°C
» 500 Pa ESP
» Unit height does not include 100 mm base frame height
» 380-400V/3ph/50Hz
» AHU with EC Fans are available

38 QUICK SELECTION GUIDE


Air Handling Units with Dx Coils
DX Cooling Coil
Supply Motor
Total Sensible Leaving Air Height x Width x Length Weight
Models Airflow Power
Capacity Capacity Temperature
l/s kW kW kW DB/WB (°C) mm kg
680x790 500 0.75 8.83 6.89 13/11.58 680 x 790 x 1980 187
800x870 750 1.10 13.33 10.34 13/11.54 800 x 870 x 2010 212
860x980 1000 1.50 17.68 13.78 13/11.58 860 x 980 x 2120 252
870x1140 1250 2.20 21.78 17.23 13/11.66 870 x 1140 x 2170 276
870x1310 1500 2.20 26.80 20.68 13/11.51 870 x 1310 x 2170 312
880x1480 1750 3.00 30.73 24.12 13/11.61 880 x 1480 x 2170 329
1000x1420 2000 3.00 34.98 27.57 13/11.64 1000 x 1420 x 2240 361
1110x1500 2500 4.00 43.93 34.46 13/11.61 1110 x 1500 x 2380 413
1180x1650 3000 5.50 53.10 41.40 13/11.57 1180 x 1650 x 2450 490
1360x1610 3500 5.50 60.68 48.24 13/11.69 1360 x 1610 x 2450 506
1480x1650 4000 7.50 70.82 55.14 13/11.57 1480 x 1650 x 2540 555
1490x1820 4500 7.50 79.31 62.03 13/11.59 1490 x 1820 x 2660 634
1490x1980 5000 7.50 87.55 68.92 13/11.63 1490 x 1980 x 2660 677

Applied Systems
1620x2140 6000 11.00 106.51 82.70 13/11.55 1610 x 2140 x 2910 868
1740x2260 7000 11.00 124.16 96.49 13/11.56 1740 x 2260 x 3050 987
1740x2540 8000 11.00 141.36 110.27 13/11.58 1740 x 2540 x 3170 1115
1870x2630 9000 15.00 158.47 124.06 13/11.60 1870 x 2630 x 3170 1178
2050x2620 10000 15.00 176.32 137.84 13/11.59 2050 x 2620 x 3170 1217
2090x2890 11000 18.50 192.91 151.62 13/11.62 2090 x 2890 x 3220 1446
2210x2940 12000 18.50 209.81 165.41 13/11.64 2210 x 2940 x 3360 1582
2220x3160 13000 22.00 220.00 171.03 13.5/11.83 2220 x 3160 x 3360 1664

AHU's include Prefilter (G4)+ Bag Filter (F7) + DX Cooling Coil + DWDI, Backward Curved Fan

Above performance data is based on following conditions:


» Cooling: Air on 24°C DB / 17°C WB and water inlet 5.5°C outlet 14.5°C
» Refrigerant R-410A, evaporation temperature 6°C and ambient temperature 46°C
» 500 Pa ESP
» Unit height does not include 100 mm base frame height
» 380-400V/3ph/50Hz
» AHU with EC Fans are available

QUICK SELECTION GUIDE 39


Fresh Air Handling Units Summer
Selection

Heat Recovery Wheel*


Supply Air Extract Air Supply Fan Extract Fan Supply Side Extract Side
Flow Flow Motor Power Motor Power Air On Air Off Air On Air Off
Model
DB/WB DB/WB DB/WB DB/WB

l/s l/s kW kW °C °C °C °C

750x1290 1000 900 2.2 1.5 46/29.1 31.5/21.67 24/17 40.3/26.54


820x1500 1500 1350 4.0 3.0 46/29.1 32.5/22.2 24/17 39.3/26.14
940x1670 2000 1800 4.0 3.0 46/29.1 32.5/22.2 24/17 39.2/26.07
1010x1830 2500 2250 5.5 4.0 46/29.1 32.5/22.43 24/17 39.2/25.85
1070x1970 3000 2700 7.5 4.0 46/29.1 32.5/22.43 24/17 39.2/25.85
1130x2080 3500 3150 7.5 4.0 46/29.1 32.4/22.35 24/17 39.4/25.98
1200x2210 4000 3600 11.0 5.5 46/29.1 32.4/22.35 24/17 39.3/25.93
1260x2310 4500 4050 11.0 5.5 46/29.1 32.4/22.35 24/17 39.3/25.93
1320x2420 5000 4500 11.0 7.5 46/29.1 32.4/22.35 24/17 39.3/25.93
1390x2620 6000 5400 15.0 7.5 46/29.1 32.4/22.35 24/17 39.4/25.98
1510x2800 7000 6300 15.0 11.0 46/29.1 32.4/22.35 24/17 39.3/25.93
1570x2970 8000 7200 18.5 11.0 46/29.1 32.5/22.43 24/17 39.2/25.85
1700x3120 9000 8100 18.5 11.0 46/29.1 32.6/22.51 24/17 39.1/25.78
1760x3300 10000 9000 22.0 15.0 46/29.1 32.4/22.35 24/17 39.3/25.93
1870x3500 11000 9900 30.0 15.0 46/29.1 32.4/22.35 24/17 39.3/25.90
FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Heat Recovery * Other Heat Recovery options are available upon request :
Wheel + Cooling Coil + DWDI, Backward Curved Fan » Plate Heat Exchanger
» Run around coil
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + DWDI, » Vertical heat pipe
Backward Curved Fan

Above performance data is based on following conditions:


» Chilled water inlet 7°C outlet 12°C
» 500 Pa ESP
» Unit height does not include 100 mm base frame height
» 380-400V/3ph/50Hz

Available with EC Fan.

40 QUICK SELECTION GUIDE


Horseshoe Heat Pipe Cooling Capacity
Height x Width x Length Weight
Precool Air On Reheat Air Off Sensible Water Pressure
Total Capacity Air On DB/WB Air Off DB/WB Water Flow
DB/WB DB/WB Capacity Drop

°C °C kW kW °C °C l/s kPa mm kg

31.5/21.67 21/16 21.20 12.90 24.2/19.4 13.7/13.49 1.01 30 1550 x 1290 x 3810 825
32.5/22.2 21/16 35.00 21.00 25.2/20.1 13.7/13.7 1.67 33 1520 x 1500 x 3880 960
32.5/22.2 21/16 46.88 28.13 25.2/20.1 13.7/13.67 2.24 30 1700 x 1670 x 4110 1136
32.5/22.43 21/16 60.44 35.06 25.2/20.3 13.7/13.7 2.89 44 1840 x 1830 x 4150 1349
32.5/22.43 21/16 72.53 42.07 25.3/20.6 13.7/13.7 3.46 25 1960 x 1970 x 4470 1556
32.4/22.35 21/16 83.16 49.06 25.1/20.2 13.7/13.7 3.97 30 2310 x 2080 x 4470 1715
32.4/22.35 21/16 95.04 56.07 25.1/20.2 13.7/13.7 4.54 37 2380 x 2210 x 4730 1965
32.4/22.35 21/16 107.27 63.29 25.1/20.2 13.7/13.67 5.12 44 2620 x 2310 x 4730 2088
32.4/22.35 21/16 118.79 70.09 25.1/20.2 13.7/13.7 5.67 25 2680 x 2420 x 4800 2226
32.4/22.35 21/16 142.55 84.10 25.1/20.2 13.7/13.7 6.81 23 2660 x 2620 x 4930 2561
32.4/22.35 21/16 166.31 98.12 25.1/20.2 13.7/13.7 7.94 29 2990 x 2800 x 5230 2980
32.5/22.43 21/16 193.42 112.18 25.2/20.3 13.7/13.7 9.23 38 3180 x 2970 x 5430 3304

Applied Systems
32.6/22.51 21/16 221.37 128.39 25.3/20.4 13.7/13.7 10.57 37 3220 x 3120 x 5550 3562
32.4/22.35 21/16 245.97 142.66 25.3/20.4 13.7/13.7 11.74 44 3520 x 3300 x 5780 4218
32.4/22.35 21/16 261.55 154.31 25.1/20.2 13.7/13.7 12.49 49 3680 x 3500 x 5810 4695

QUICK SELECTION GUIDE 41


Fresh Air Handling Units Summer
Selection

Heat Recovery Wheel*


Supply Air Extract Air Supply Fan Extract Fan Supply Side Extract Side
Flow Flow Motor Power Motor Power Air On Air Off Air On Air Off
Model
DB/WB DB/WB DB/WB DB/WB

l/s l/s kW kW °C °C °C °C

1930x3630 12000 10800 30.0 15.0 46/29.1 32.4/22.35 24/17 39.3/25.93


1990x3760 13000 11700 30.0 15.0 46/29.1 32.4/22.35 24/17 39.4/25.98
2060x3890 14000 12600 30.0 18.5 46/29.1 32.4/22.35 24/17 39.3/25.90
2120x4010 15000 13500 37.0 18.5 46/29.1 32.4/22.35 24/17 39.3/25.93
2180x4130 16000 14400 37.0 18.5 46/29.1 32.4/22.35 24/17 39.3/25.93
2240x4240 17000 15300 37.0 22.0 46/29.1 32.4/22.35 24/17 39.4/25.98
2310x4350 18000 16200 37.0 22.0 46/29.1 32.4/22.35 24/17 39.4/25.98
2370x4460 19000 17100 45.0 30.0 46/29.1 32.5/22.43 24/17 39.2/25.85
2430x4560 20000 18000 2 x 22 2 x 15 46/29.1 32.24/23.68 24/17 39.41/24.57
2440x4720 21000 18900 2 x 30 2 x 15 46/29.1 32.2/23.65 24/17 39.45/24.61
2440x4930 22000 19800 2 x 30 2 x 15 46/29.1 32.17/23.62 24/17 39.49/24.64
2450x5180 23000 20700 2 x 30 2 x 15 46/29.1 32.3/23.76 24/17 39.3/24.48
2450x5390 24000 21600 2 x 30 2 x 18.5 46/29.1 32.4/23.81 24/17 39.2/24.43
2460x5600 25000 22500 2 x 30 2 x 18.5 46/29.1 32.3/23.77 24/17 39.3/24.47
FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Heat Recovery * Other Heat Recovery options are available upon request :
Wheel + Cooling Coil + DWDI, Backward Curved Fan » Plate Heat Exchanger
» Run around coil
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + » Vertical heat pipe
DWDI, Backward Curved Fan

Above performance data is based on following conditions:


» Chilled water inlet 7°C outlet 12°C
» 500 Pa ESP
» Unit height does not include 100mm base frame height
» 380-400V/3ph/50Hz

Available with EC Fan.

42 QUICK SELECTION GUIDE


Horseshoe Heat Pipe Cooling Capacity
Height x Width x Length Weight
Precool Air On Reheat Air Off Sensible Water Pressure
Total Capacity Air On DB/WB Air Off DB/WB Water Flow
DB/WB DB/WB Capacity Drop

°C °C kW kW °C °C l/s kPa mm kg

32.4/22.35 21/16 285.11 168.21 25.1/20.2 13.7/13.7 13.61 21 3800 x 3630 x 5950 4998
32.4/22.35 21/16 308.86 182.23 25.1/20.2 13.7/13.7 14.75 14 3920 x 3760 x 6120 5361
32.4/22.35 21/16 332.62 196.25 25.1/20.2 13.7/13.7 15.88 16 4060 x 3890 x 6120 5604
32.4/22.35 21/16 356.38 210.26 25.1/20.2 13.7/13.7 17.01 19 4120 x 4010 x 6270 5898
32.4/22.35 21/16 380.14 224.28 25.1/20.2 13.7/13.7 18.15 21 4300 x 4130 x 6310 6349
32.4/22.35 21/16 403.90 238.30 25.1/20.2 13.7/13.7 19.28 23 4420 x 4240 x 6310 6406
32.4/22.35 21/16 427.66 252.32 25.1/20.2 13.7/13.7 20.42 26 4720 x 4350 x 6920 6933
32.5/22.43 21/16 459.36 266.43 25.2/20.3 13.7/13.7 21.93 19 4560 x 4460 x 6920 7227
32.24/23.68 21/16 569.69 274.48 24.9/21.6 13.7/13.7 28.49 25 4620 x 4560 x 5990 7124
32.2/23.65 21/16 626.52 288.20 24.9/21.6 13.7/13.7 29.91 34 4640 x 4720 x 5960 7391
32.17/23.62 21/16 656.36 301.93 24.9/21.6 13.7/13.7 31.34 38 4580 x 4930 x 5960 7603
32.3/23.76 21/16 696.39 320.34 25.0/21.7 13.7/13.7 33.25 44 4600 x 5180 x 6100 7840

Applied Systems
32.4/23.81 21/16 737.36 339.19 25.1/21.8 13.7/13.7 35.19 50 4600 x 5390 x 6100 8112
32.3/23.77 21/16 756.95 348.20 25.0/21.7 13.7/13.7 36.14 44 4620 x 5600 x 6130 8728

QUICK SELECTION GUIDE 43


Fresh Air Handling Units (34°C / 32°C) Winter
Selection

Heat Recovery Wheel*


Supply Air Extract Air Supply Fan Extract Fan Supply Side Extract Side
Flow Flow Motor Power Motor Power Air On Air Off Air On Air Off
Model
DB/WB DB/WB DB/WB DB/WB

l/s l/s kW kW °C °C °C °C

750x1290 1000 900 2.2 1.5 34/32 28.2/22.1 24/17 30.8/29.9


820x1500 1500 1350 4.0 3.0 34/32 28.3/21.9 24/17 30.6/29.9
940x1670 2000 1800 4.0 3.0 34/32 28.1/21.9 24/17 30.8/29.9
1010x1830 2500 2250 5.5 4.0 34/32 28.4/22.8 24/17 30.5/29.25
1070x1970 3000 2700 7.5 4.0 34/32 28.3/22.5 24/17 30.6/29.5
1130x2080 3500 3150 7.5 4.0 34/32 28.3/22.6 24/17 30.5/29.3
1200x2210 4000 3600 11.0 5.5 34/32 28.3/22.52 24/17 30.6/29.51
1260x2310 4500 4050 11.0 5.5 34/32 28.4/22.8 24/17 30.5/29.28
1320x2420 5000 4500 11.0 7.5 34/32 28.3/22.59 24/17 30.6/29.46
1390x2620 6000 5400 15.0 7.5 34/32 28.4/22.79 24/17 30.5/29.28
1510x2800 7000 6300 15.0 11.0 34/32 28.3/22.59 24/17 30.6/29.46
1570x2970 8000 7200 18.5 11.0 34/32 28.4/22.94 24/17 30.4/29.09
1700x3120 9000 8100 22.0 11.0 34/32 28.5/23.23 24/17 30.3/28.85
1760x3300 10000 9000 22.0 15.0 34/32 28.4/23.01 24/17 30.4/29.04
1870x3500 11000 9900 30.0 15.0 34/32 28.4/22.94 24/17 30.4/29.09
FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Heat Recovery Wheel + * Other Heat Recovery options are available upon request :
Chilled Water Coil + DWDI, Backward Curved Fan. » Plate Heat Exchanger
» Run around coil
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + DWDI, Back- » Vertical heat pipe
ward Curved Fan.

Above performance data is based on following conditions:


» Chilled water inlet 7°C outlet 12°C
» 500 Pa ESP
» Unit height does not include 100 mm base frame height
» 380-400V/3ph/50Hz

Available with EC Fan.kindly contact sales responsible

44 QUICK SELECTION GUIDE


Horseshoe Heat Pipe Cooling Capacity
Height x Width x Length Weight
Precool Air On Reheat Air Off Sensible Water Pressure
Total Capacity Air On DB/WB Air Off DB/WB Water Flow
DB/WB DB/WB Capacity Drop

°C °C kW kW °C °C l/s kPa mm kg

28.2/22.1 19.8/15.6 24.29 10.20 22.0/20.3 13.7/13.7 1.16 39 1440 x 1290 x 3710 800
28.3/21.9 19.8/15.6 35.79 15.75 22.2/20.2 13.7/13.7 1.71 35 1520 x 1500 x 3830 948
28.1/21.9 19.8/15.6 47.74 20.53 22.0/20.2 13.7/13.7 2.28 31 1700 x 1670 x 4090 1211
28.4/22.8 19.8/15.6 70.40 26.75 22.4/21.2 13.7/13.7 3.36 25 1840 x 1830 x 4100 1377
28.3/22.5 19.8/15.6 81.86 31.93 22.3/21.0 13.7/13.7 3.91 31 2080 x 1970 x 4240 1561
28.3/22.6 19.8/15.6 93.99 36.66 22.2/20.9 13.7/13.7 4.49 38 2310 x 2080 x 4530 1706
28.3/22.52 19.8/15.6 109.15 42.57 22.3/21 13.7/13.7 5.21 48 2460 x 2290 x 4670 2102
28.4/22.8 19.8/15.6 122.79 47.89 22.3/21 13.7/13.7 5.86 27 2700 x 2390 x 4670 2215
28.3/22.59 19.8/15.6 134.28 52.37 22.2/20.9 13.7/13.7 6.43 22 2760 x 2500 x 4740 2362
28.4/22.79 19.8/15.6 161.11 62.83 22.3/20.9 13.7/13.7 7.69 29 2730 x 2700 x 4910 2682
28.3/22.59 19.8/15.6 191.01 74.49 22.3/21 13.7/13.7 9.12 37 3070 x 2880 x 5210 3127
28.4/22.94 19.8/15.6 225.30 83.36 22.3/21.2 13.7/13.7 10.76 42 3270 x 3050 x 5410 3478

Applied Systems
28.5/23.23 19.8/15.6 261.37 96.71 22.4/21.4 13.7/13.7 12.48 53 3240 x 3200 x 5520 3898
28.4/23.01 19.8/15.6 281.62 104.20 22.3/21.2 13.7/13.7 13.45 42 3600 x 3300 x 5790 4448
28.4/22.94 19.8/15.6 309.78 114.62 22.3/21.2 13.7/13.7 14.79 42 3680 x 3500 x 5820 4764

QUICK SELECTION GUIDE 45


Fresh Air Handling Units (34°C / 32°C) Winter
Selection

Heat Recovery Wheel*


Supply Air Extract Air Supply Fan Extract Fan Supply Side Extract Side
Flow Flow Motor Power Motor Power Air On Air Off Air On Air Off
Model
DB/WB DB/WB DB/WB DB/WB

l/s l/s kW kW °C °C °C °C

1930x3630 12000 10800 30.0 15.0 34/32 28.4/22.91 24/17 30.5/29.21


1990x3760 13000 11700 30.0 15.0 34/32 28.4/22.96 24/17 30.4/29.08
2060x3890 14000 12600 30.0 18.5 34/32 28.4/22.91 24/17 30.5/29.22
2120x4010 15000 13500 30.0 18.5 34/32 28.4/22.92 24/17 30.4/29.09
2180x4130 16000 14400 37.0 18.5 34/32 28.4/22.87 24/17 30.5/29.23
2240x4230 17000 15300 37.0 22.0 34/32 28.4/22.89 24/17 30.5/29.22
2310x4330 18000 16200 2 x 18.5 2 x 11 34/32 28.5/23.13 24/17 30.4/29.02
2370x4430 19000 17100 2 x 22 2 x 11 34/32 28.5/23.29 24/17 30.3/28.81
2430x4510 20000 18000 2 x 22 2 x 11 34/32 29.70/25.43 24/17 28.90/26.75
2440x4720 21000 18900 2 x 22 2 x 15 34/32 29.70/25.41 24/17 28.9/26.7
2440x4930 22000 19800 2 x 22 2 x 15 34/32 29.80/25.73 24/17 28.8/26.45
2450x5180 23000 20700 2 x 30 2 x 15 34/32 29.80/25.70 24/17 28.80/26.48
2450x5390 24000 21600 2 x 30 2 x 18.5 34/32 29.80/25.68 24/17 28.80/26.51
2460x5600 25000 22500 2 x 30 2 x 18.5 34/32 29.90/25.85 24/17 28.70/26.33

FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Heat Recovery * Other Heat Recovery options are available upon request :
Wheel + Chilled Water Coil + DWDI, Backward Curved Fan. » Plate Heat Exchanger
» Run around coil
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + DWDI, » Vertical heat pipe
Backward Curved Fan.

Above performance data is based on following conditions:


» Chilled water inlet 7°C outlet 12°C
» 500 Pa ESP
» Unit height does not include 100 mm base frame height
» 380-400V/3ph/50Hz

Available with EC Fan.kindly contact sales responsible

46 QUICK SELECTION GUIDE


Horseshoe Heat Pipe Cooling Capacity
Height x Width x Length Weight
Precool Air On Reheat Air Off Sensible Water Pressure
Total Capacity Air On DB/WB Air Off DB/WB Water Flow
DB/WB DB/WB Capacity Drop

°C °C kW kW °C °C l/s kPa mm kg

28.4/22.91 19.8/15.6 337.95 125.04 22.3/21.2 13.7/13.7 16.13 48 3800 x 3630 x 5960 5052
28.4/22.96 19.7/15.6 366.06 139.10 22.4/21.2 13.7/13.7 17.48 17 3920 x 3760 x 6100 5423
28.4/22.91 19.8/15.6 394.27 145.88 22.3/21.2 13.7/13.7 18.82 20 4060 x 3890 x 5910 5688
28.4/22.92 19.8/15.6 422.43 156.30 22.3/21.2 13.7/13.7 20.17 23 4120 x 4010 x 6420 6095
28.4/22.87 19.8/15.6 443.58 168.56 22.3/21.2 13.7/13.7 21.18 15 4300 x 4130 x 6620 6620
28.4/22.89 19.8/15.6 478.76 177.14 22.3/21.2 13.7/13.7 22.86 17 4360 x 4230 x 6150 6494
28.5/23.13 19.8/15.6 522.74 193.41 22.4/21.4 13.7/13.7 24.96 20 4380 x 4330 x 5700 6186
28.5/23.29 19.8/15.6 568.69 204.73 22.4/21.6 13.7/13.7 27.15 23 4440 x 4430 x 5820 6479
29.70/25.43 20.3/15.8 764.50 252.29 24.0/23.4 13.7/13.7 36.50 39 4560 x 4510 x 5820 6683
29.70/25.41 20.4/15.8 802.72 264.90 24.0/23.4 13.7/13.7 38.32 44 4640 x 4720 x 5820 6954
29.80/25.73 20.4/15.8 883.38 291.52 24.4/23.8 13.7/13.7 42.17 39 4580 x 4930 x 6030 7180
29.80/25.70 20.4/15.8 901.26 297.42 24.2/23.6 13.7/13.7 43.03 42 4600 x 5180 x 6030 7605

Applied Systems
29.80/25.68 20.4/15.8 940.45 310.35 24.2/23.6 13.7/13.7 44.90 47 4600 x 5390 x 6030 7818
29.90/25.85 20.4/15.8 1003.85 331.27 24.4/23.8 13.7/13.7 47.93 44 4680 x 5600 x 6030 8174

QUICK SELECTION GUIDE 47


Fresh Air Handling Units with Dx Coil Summer
Selection

Heat Recovery Wheel*


Supply Air Extract Air Supply Fan Extract Fan Supply Side Extract Side
Flow Flow Motor Power Motor Power Air On Air Off Air On Air Off
Model
DB/WB DB/WB DB/WB DB/WB

l/s l/s kW kW °C °C °C °C

750x1290 1000 900 2.2 1.5 46/29.1 31.5/21.67 24/17 40.3/26.54


820x1500 1500 1350 4.0 3.0 46/29.1 32.5/22.2 24/17 39.3/26.14
940x1670 2000 1800 4.0 3.0 46/29.1 32.5/22.2 24/17 39.2/26.07
1010x1830 2500 2250 5.5 4.0 46/29.1 32.5/22.43 24/17 39.2/25.85
1070x1970 3000 2700 7.5 4.0 46/29.1 32.5/22.43 24/17 39.2/25.85
1130x2080 3500 3150 7.5 4.0 46/29.1 32.4/22.35 24/17 39.4/25.98
1200x2210 4000 3600 11.0 5.5 46/29.1 32.4/22.35 24/17 39.3/25.93
1260x2310 4500 4050 11.0 5.5 46/29.1 32.4/22.35 24/17 39.3/25.93
1320x2420 5000 4500 11.0 7.5 46/29.1 32.4/22.35 24/17 39.3/25.93
1390x2620 6000 5400 15.0 7.5 46/29.1 32.4/22.35 24/17 39.4/25.98
1510x2800 7000 6300 15.0 11.0 46/29.1 32.4/22.35 24/17 39.3/25.93
1570x2970 8000 7200 18.5 11.0 46/29.1 32.5/22.43 24/17 39.2/25.85
FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Horseshoe * Other Heat Recovery options are available upon request
heat pipe + Heat Recovery Wheel + Dx Cooling Coil + DWDI, Backward Curved Fan

FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel +
DWDI, Backward Curved Fan

Above performance data is based on following conditions:


» Refrigerant R410A, evaporation temperature 6°C and ambient temperature 46°C
» 500 Pa ESP
» Unit height does not include 100 mm base frame height
» 380-400V/3ph/50Hz

Available with EC Fan.

48 QUICK SELECTION GUIDE


Horseshoe Heat Pipe Cooling Capacity
Height x Width x Length Weight
Precool Air On Reheat Air Off Sensible
Total Capacity Air On DB/WB Air Off DB/WB
DB/WB DB/WB Capacity

°C °C kW kW °C °C mm kg

31.5/21.67 21/16 23.00 13.20 24.2/19.4 13.7/12.88 1550 x 1290 x 3740 807
32.5/22.2 21/16 38.90 21.80 25.2/20.1 13.7/12.85 1520 x 1500 x 3810 945
32.5/22.2 21/16 51.80 29.00 25.2/20.1 13.7/12.87 1700 x 1670 x 4040 1116
32.5/22.43 21/16 66.30 36.30 25.2/20.3 13.7/12.95 1840 x 1830 x 4080 1332
32.5/22.43 21/16 79.70 43.50 25.3/20.6 13.7/13.93 1960 x 1970 x 4450 1548
32.4/22.35 21/16 91.80 50.30 25.1/20.2 13.7/12.91 2310 x 2080 x 4450 1705
32.4/22.35 21/16 104.90 57.50 25.1/20.2 13.7/12.9 2380 x 2210 x 4710 1956
32.4/22.35 21/16 117.70 64.70 25.1/20.2 13.7/12.93 2620 x 2310 x 4710 2088
32.4/22.35 21/16 131.00 71.90 25.1/20.2 13.7/12.92 2680 x 2420 x 4780 2226
32.4/22.35 21/16 156.30 86.30 25.1/20.2 13.7/12.96 2660 x 2620 x 4910 2555
32.4/22.35 21/16 183.40 100.60 25.1/20.2 13.7/12.91 2990 x 2800 x 5210 2982
32.5/22.43 21/16 212.50 116.10 25.2/20.3 13.7/12.93 3180 x 2970 x 5360 3298

Applied Systems
QUICK SELECTION GUIDE 49
Fresh Air Handling Units with Dx Coil (34°C - 32°C) Winter
Selection

Heat Recovery Wheel*


Supply Air Extract Air Supply Fan Extract Fan Supply Side Extract Side
Flow Flow Motor Power Motor Power Air On Air Off Air On Air Off
Model
DB/WB DB/WB DB/WB DB/WB

l/s l/s kW kW °C °C °C °C

750x1290 1000 900 3.0 2.2 34/32 28.2/22.1 24/17 30.8/29.9


820x1500 1500 1350 3.0 3.0 34/32 28.3/22.0 24/17 30.6/29.98
940x1670 2000 1800 4.0 3.0 34/32 28.1/22.0 24/17 30.8/29.9
1000x1780 2500 2250 5.5 3.0 34/32 28.4/22.9 24/17 30.5/28.25
1070x1970 3000 2700 7.5 4.0 34/32 28.4/22.8 24/17 30.5/29.3
1130x2080 3500 3150 7.5 4.0 34/32 28.3/22.6 24/17 30.5/29.34
1200x2210 4000 3600 11.0 5.5 34/32 28.4/22.8 24/17 30.5/29.3
1260x2310 4500 4050 11.0 5.5 34/32 28.4/22.8 24/17 30.5/29.3
1320x2420 5000 4500 11.0 7.5 34/32 28.3/22.7 24/17 30.6/29.5
1390x2620 6000 5400 15.0 7.5 34/32 28.3/22.7 24/17 30.6/29.5
1510x2800 7000 6300 15.0 11.0 34/32 28.4/22.8 24/17 30.5/29.3
1570x2970 8000 7200 18.5 11.0 34/32 28.4/22.9 24/17 30.4/29.09

FAHU supply section includes OA Damper+Prefilter (G3) + Bag Filter (F7) + Heat Recovery
Wheel + DX Cooling Coil + DWDI, Backward Curved Fan.

FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + DWDI,
Backward Curved Fan.

*Other Heat Recovery option are available upon request

Above performance data is based on following conditions:


» Refrigerant R410A, evaporation temperature 6°C and ambient temperature 46°C
» 500 Pa ESP
» Unit height does not include 100 mm base frame height
» 380-400V/3ph/50Hz
» Available with EC Fan. Kindly contact sales responsible

50 QUICK SELECTION GUIDE


Horseshoe Heat Pipe Cooling Capacity
Height x Width x Length Weight
Precool Air On Reheat Air Off Sensible
Total Capacity Air On DB/WB Air Off DB/WB
DB/WB DB/WB Capacity

°C °C kW kW °C °C mm kg

28.2/22.1 19.9/15.6 24.7 10.5 22.0/20.3 13.7/13.58 1440 x 1290 x 3650 767
28.3/22.0 19.8/15.6 36.7 16.1 22.2/20.2 13.7/13.5 1520 x 1500 x 3810 929
28.1/22.0 19.8/15.6 48.7 21.0 22.0/20.2 13.7/13.54 1820 x 1670 x 4070 1190
28.4/22.9 19.7/15.6 69.9 27.6 22.4/21.2 13.7/13.7 1940 x 1780 x 4150 1314
28.4/22.8 19.8/15.6 81.6 32.7 22.3/21.0 13.7/13.7 1960 x 1970 x 4220 1478
28.3/22.6 19.8/15.6 93.8 37.7 22.2/20.9 13.7/13.7 2310 x 2080 x 4670 1721
28.4/22.8 19.8/15.6 108.9 43.6 22.3/21.0 13.7/13.7 2380 x 2210 x 4580 1897
28.4/22.8 19.8/15.6 122.4 49.0 22.3/21.0 13.7/13.7 2620 x 2310 x 4620 2030
28.3/22.7 19.8/15.6 134.0 53.8 22.2/20.9 13.7/13.7 2580 x 2420 x 4690 2180
28.3/22.7 19.7/15.6 161.3 65.3 22.3/20.9 13.7/13.69 2660 x 2620 x 5010 2524
28.4/22.8 19.8/15.6 190.5 76.2 22.3/21.0 13.7/13.7 2990 x 2800 x 5160 2894
28.4/22.9 19.8/15.6 223.5 87.2 22.3/21.2 13.7/13.7 3080 x2970 x 5260 3209

Applied Systems
QUICK SELECTION GUIDE 51
Technical Information
Motor Efficiency Information Hygienic Units Pre-Requirements
Never specify IE1 (EFF2) motors. Any heat exchanger should not be wider than 300 mm and with access on both
On 22 July 2009, Commission Regulation (EC) No 640/2009 implementing Directive sides to allow cleaning. Keep the number of rows to max 6, however, if 8 rows comes
2005/32/EC states that in the EU, with the exception of some special applications, in 300 mm, then it is ok.
motors shall not be less efficient than the IE3 efficiency level as from 1 January 2015.
» T2/TB2 construction minimum
In detail: » Internal skin made of aluminum alloy or AISI 304 (preferable)
» IE2 by June 16, 2011 » On viewable surfaces like dampers or doors gasket must be rubber/EPDM (open
» IE3 by January 1, 2015 (for motors >=7.5 to 375 kW) and IE2 only in combination or closed cell gasket not acceptable)
with an adjustable speed drive » Only front release filter frame
» IE3 for all motors by January 1, 2017, (for motors from 0.75 to 375 kW). » Coil with aluminum or stainless steel frame. Fins preferably with ALUVER paint
» Coils with access on both side of the coil for cleaning
» Sloped drain pan made of stainless steel
DX Coil Capacity » Moisture eliminator made of stainless steel if required. Usually not recommended.
Total cooling capacity for AHU DX coil MUST be equal to the Condensing Unit » Sound attenuator stainless steel frame and film protection (melinex or similar to
cooling capacity. protect against fiber migration. Perforated plate also acceptable however not
recommendable as difficult to clean
AHU DX coil evaporation temperature MUST be equal to Condensing Unit saturated » Epoxy painted fan with paint strong enough to resist against abrasion. Typically a
suction temperature + 2°F. 4 layer epoxy pain. Only plug fans acceptable
» Sealant food grade
No. of AHU DX coil refrigerant circuits MUST be equal to the no. of Condensing Unit » No hollow sections allowed and if tubular frames are to be used they must be
refrigerant circuits. closed at the end with caps or welded

Temperature Rise
Electrical Power Input Calculation Temperature rise due to air compression (fan work):
Belt-Driven fans :
Electrical Power Input calculation = (Break power + 12% drive loss) / efficiency

EC fans :
Electrical Power Input is same as the shaft power. Where :
∆T : Fan Temperature rise
Ps : Fan brake shaft power
SFP Calculation μ : Fan efficiency
Cp : Specific heat capacity (1 for air)
q : air flow in m3/s
Where : p : density (1.2 kg/m3)
SFP: AHU Specific Power Input
For a fan 5.56 m3/s @ 14.6 kw break power at 72% fan efficiency the temperature rise
: Sum of all electric power input of the fan inside the AHU. So if you have 2 is approximately 0.6 °C
fan supply + 2 fan return your will have 4 power input
Temperature rise due motor heat rejection :
AF: This should be the AHU total supply air flow or if the unit is with supply and
return fans then the highest between the two

52 QUICK SELECTION GUIDE


Where : Heat Wheel Efficiency and Effectiveness Calculation
∆Tm : Motor Temperature rise
Pm : Motor power Kw
μm : motor efficiency efficiency
q : air flow in m3/s
p : density (1.2 kg/m3)

For a 18.5 kW motor at 5.53 m3/s at 85% motor efficiency the temperature rise is
approximately 0.41°C

FAN LAWS CFM1 = RPM1


CFM2 RPM2

SP1 = (RPM1)2 = (CFM1)2


SP2 (RPM2)2 (CFM2)2

BHP1 = (RPM1)3 = (CFM1)3


BHP2 (RPM2)3 (CFM2)3

Applied Systems
Coil Bypass Factor & Efficiency Formula
Coil Bypass Factor = (Air Outlet Temperature – T) / (Air Inlet Temperature – T)
T : Fluid Average Temperature
Fluid average temperature = (Inlet Temp + Outlet Temp)/2

Efficiency = 1 - Bypass Factor


Commonly Used Air Side Formulas
Total Heat = TH = 1.2*Q*∆h (kW)
Sensible Heat = SH = 1.2*Q*∆T (kW)
Latent Heat = LH = 3.0*Q*∆w (kW)

∆T : Temperature difference, °C
∆h : Enthalpy difference, kJ/kg
∆w : Moisture concentration, g/kg dry air
Q : Air flow rate, m³/s

QUICK SELECTION GUIDE 53


Modular Chiller Plant
High Efficiency, Low Cost Alternative
to Site-Built Central Plants
The Daikin Modular Chiller Plant (MCP) combines a chiller, cooling tower,
pumps and interconnecting condenser water piping, low voltage
MCC, Medium Voltage MCC (if applicable) PLC and chemical
dosing system in a pre-engineered and pre-assembled Air
Conditioned module.

Daikin MCP solutions are engineered for the demands of the


buildings today and highly flexible to accommodate any expansion
in the years ahead.

Benefits
» Fast track projects with critical deadlines and tight construction schedules
» Limited space facilities where you don’t want to sacrifice interior space to house a
central chiller plant
» MCP is an efficient and affordable alternative to the stick-built chiller central plant, suitable for
cost conscious projects

Daikin shall design, manufacture, deliver and install a self-contained plant.

54 QUICK SELECTION GUIDE


Key Features Standard Features and Options
» The Modular Chiller Plant can be customised based » Daikin chiller, 300 to 3,200 TR per module
on Consultant's specific requirements » Cooling tower with VFD fan motors
» Can be designed for primary, secondary or variable » Vertical in-line pumps, suction guides and 3-way valve
primary systems » STD Schedule steel chilled water piping, primer coated
» The MCP is pre-engineered, factory-fabricated, and with insulation
pressure tested as a complete unit » STD Schedule steel condenser piping, Paint Coated
» MCP structure is structurally rated for IBC 2A Seismic
» Electrical distribution panel with single point power per
Design Category C
module
» A single Chiller Module capacity can range from 300
» Enclosure of HVAC system
TR up to 3,200 TR
» MCP PLC controls with Modbus TCP interface
» Any capacity above 3,000 TR can be achieved with
multiple Chiller Modules » Raise Floor for Electrical Area
» Depending on the size of the plant, the chiller » Access doors for Maintenance Requirements
modules will be split into multiple sections for » Fully welded steel structure, as well as painted
shipping purposes » Internal floor drains piped to single discharge
» Unloading and re-assembly of chiller modules at » Water treatment equipment and eyewash

Modular Central Plants


site will be handled by Daikin Professional technical » Redundant pump (optional)
team » Expansion tank and make-up water
» Start-up, commissioning & training services from our » Tower drain and make-up water piping
in-house Service Team is included » Tower Side Stream filtration

Daikin Advantages
Quality The MCP factory fabrication and assembly provide quality that exceeds outside field practices.
Paint finish on all structural steel and condenser water piping is standard. Components have
weather resistant finish that withstands 500-hour exposure to the salt spray test specified in
ASTM B 117.
Efficiency The Daikin chillers used in the MCP are industry leaders in efficiency. In addition, the MCP comes
standard with cooling tower VFDs for enhanced part load performance.
Simplicity Single source OEM supplier.

QUICK SELECTION GUIDE 55


Daikin Service
Your Reliable Partner

Sustainable HVAC solutions Daikin products are as good as their name. That's why Daikin offers a range of services
that offer increased efficiency, life cycle economy and guaranteed satisfaction, not to
mention peace of mind. At Daikin, we understand that HVAC is a big investment - not just
for Energy Saving for the initial installation, but also in terms of maintenance. Whether you need a technical
assistance, find the perfect service plan or optimise your system, Daikin is here for you.

Control solutions to optimise Energy Audit & Upgrade Turnkey solution for
energy Solution energy savings
» Chiller system manager » Targetted energy audits » Turnkey solution involving equipment
» Integration of AHU / Pumps » Upgrade of controls replacement with efficient products
» Remote KW monitoring & optimisation » Chiller retrofits » Improved ROI with system modernisation
» Remote software upgrades » Inverterisation involving chillers / DX / VRV, system control,
» PC workstation » Comply with latest regulations cooling towers, pumps, AHUs, FCUs
» Modernisation of controls » McQuay Daikin and other reputed brands
» Protecting environment & minimising carbon
footprint
» Customised solutions

56 QUICK SELECTION GUIDE


Daikin After-Sales Service Maintenance Agreements
Portfolio for Reliability Daikin Middle East and Africa FZE provides support to its installed
base by providing the customised solution to the asset owners
Daikin is 24x7 available to support on your maintenance & repair needs using authorised and facility management teams across GCC and Africa.
factory-trained technicians to provide customised maintenance solutions.
Various combination of labour, maintenance, consumables,
» Annual Maintenance Agreements » Special Service - NDT operation, etc. are used to serve our prestigious customer base,
o Comprehensive Maintenance o Eddy current test backed up by our factory trained team of technicians.
Agreement o Oil test and analysis
o Labour Maintenance Agreement o Vibration analysis The agreements can encompass various HVAC products like VRV/
o Inspection Maintenance Agreement o Thermal imaging DX, Unitary Products, AHU, FCU, Applied Chillers, Cooling Towers,
Pumps, etc.
o Remote Monitoring Service o Chilled water analysis
o Air Conditioning Intelligent Network
» VRV Project Management
» Repairs and overhauls
Some of the agreement types:
» Comprehensive Agreement
o Onsite repairs » Training & Development
Includes all preventive services, all breakdown labour, all
o Compressor rebuilding of various
parts,material and consumables to give peace of mind to
types » Spare Parts Support customers
 Centrifugal compressor, Screw
compressors, Reciprocating » Labour Agreement

Service
compressors Includes all preventive services and all breakdown labour

» Breakdown / emergency repair services » Inspection Agreement


o Special Services Includes specialised inspection of equipment and
 Heat exchanger replacement submission of report
 Heat exchanger protection
coatings » Remote Monitoring Service
 Heat exchanger cleaning Includes specialised attention by monitoring your
equipment and provide timely feedback
 Heat recovery
 Refrigerant monitoring for plant
rooms
QUICK SELECTION GUIDE 57
Region UAE Abu Dhabi
ESMA from 1/11/15 Estidama (based on ASHRAE 90.1:2007) from 07/2011 QCC (based on Ashrae 90.1 2013) certification scheme
Product Product Rated Building Building Villa Rated
Rated Capacity EER SEER COP EER IPLV IPLV
Category Endurance category Capacity COP SEER COP capacity
Test 2h Product Btu/
Units Btu/h Btu/h /W kW W /W Btu/h/W W /W Btu/h /W kW W/W Btu/h/W W/W
category h/W
Temperature
46°C 52°C 35°C 35°C 35°C 35°C 35°C 46°C 35°C 35°C 35°C 35°C
condition

< 40 3.4 11.6


Non-Ducted
Residential 6.8 yes < 19 13 3.4
Residential Split
40≤
Split system 3.3 11.3
CC<70
and single
19 ≤ CC package 70 ≤ CC<
< 135000 8.1 3.28 3.13 10.7 2.87 9.8
<40 223

All Other Split 135000 ≤CC< Air cooled,


7.9 40≤ CC<70 3.22 3.4 ≥ 223 3.02 10.3 2.78 9.5
and Package 240000 Split system
DX
Units 240000≤ CC and single 70 ≤ CC< Condensing
7.5 package 2.93 9.7 ≥ 40 3.3 11.3
<760000 223 units
≥ 760000 7.2 ≥ 223 2.78 9.4 < 19 3.40 11.6
19 ≤ CC
< 90000 8.3 VRF 3.28 11.2
<40
Multi Split multisplit air
90000 < CC ≤ condtioners 40≤
(including VRV) 7.8 3.22 11.0
135000 CC<70
≥ 135000 7.5 ≥ 70 2.93 10.0
Units kW Btu/h /W kW W/W W/W kW W/W W/W
Temperature
35°C 52°C 35°C 35°C 35°C 35°C
condition
< 630 8.5 <528 2.826 3.694
Air Cooled yes Air cooled All 2.80 3.05 3.40 Air cooled
≥ 630 9.5 ≥528 2.826 3.768

< 528 13.5 Reciprocating All 4.20 5.05 3.40 <264 4.513 5.588

264≤
< 528 4.45 5.25 3.40 Water cooled 4.542 5.724
CC<528
positive
Chillers 528 ≤ CC< 528≤
528 ≤ CC< 1055 15.0 Rotary screw 4.90 5.60 3.40 displacement 5.177 6.070
1055 CC<1055
Water Cooled
≥ 1055 kW 5.50 6.15 3.40 ≥1055 5.678 6.519

< 528 5.00 5.25 3.40 <1055 5.678 5.907


Water cooled 1055≤
≥ 1055 17.0 Centrifugal 528-1055 5.55 5.90 3.40 6.112 6.412
centrifugal CC<2110
≥ 1055 6.10 6.40 3.40 ≥2110 6.176 6.531
Authority ESMA Abu Dhabi Urban Planning Council QCC -voluntary certification scheme, link with Estidama
Dubai KSA
Green Building legislation SASO from 1/1/2015

Size category EER EER IPLV Rated capacity EER EER Operability

Product Product
Btu/h Btu /h /W Btu /h /W Btu/h Btu/h /W Btu/h /W
category category

35°C 46°C 35°C 46°C 52°C

Single Split
Split system < 65000 9.5 6.6 ≤70000 11.5 8.28
system

65000 < CC ≤
Ducted split < 65000 9.5 6.6 11.2
135000
135000 < CC ≤
65000 ≤ CC <135000 9.5 6.6 11.0
Air cooled, 240000
yes
135000 ≤ CC Unitary 240000 <CC ≤
9.5 6.6 10.0
<240000 760000
240000 ≤ CC
9.5 6.6 > 760000 9.7
Air cooled, Split <760000
system and
≥ 760000 9.0 6.3 ≤65000 11.2
single package
65000 < CC ≤
11.2 (11 for H/P)
Multi split 135000
yes
(including VRV) 135000 < CC ≤
11.0 (10.6 for H/P)
240000
> 240000 10.0 (9.5 for H/P)
tons W/W W/W kW Btu/h /W

35°C 46°C 35°C 35°C

Condensing ≤ 39.56 11.0


Air cooled
All 2.8 1.9 3.05 units,
Chiller > 39.56 10.5 yes
air cooled

Reciprocating All 4.2 2.75 5.05 Air Cooled all 9.7 yes

<150 4.45 2.9 ≤ 263.7 15.4

263.7 < CC ≤
Screw and scroll 150 ≤ CC <300 4.9 3.2 Water cooled 16.0
527.4
screw
527.4 < CC ≤
≥ 300 5.6 3.6 17.7
1054.8
<150 6.0 > 1054.8 19.2

Centrifugal 150 ≤ CC <300 6.5 7.1 ≤ 1054.8 17.3


Centrifugal
≥ 300 6.5 7.68 > 1054.8 20.5
Dubai Municipality SASO
Region Kuwait Bahrain Qatar
MEW-R6 from M/2014 From 1/7/2016 From 1/7/2016
Power Endurance Rated Rated
Capacity EER EER EER EER
rating test 2h capacity capacity
Product Product Product
Units RT kw/RT kw/RT Btu/h Btu/h /W Btu/h /W Btu/h Btu/h /W Btu/h /W
category category category
Temperature
48°C 52°C 35°C 46°C 35°C 46°C
condition

Split system ≤70000 9.5 6.84 Split system ≤70000 9.5 6.84

Split ≥70000 Split ≥70000


DX All DX All 1.6 yes
Package All Package All
Multi split Multi split
All All
(including VRV) (including VRV)
Units Tons kW/RT
Temperature
35°C
condition
Air Cooled All 1.6 Air Cooled Air Cooled

< 250 1.45

Water Cooled 250 ≤ CC Water Cooled Water Cooled


Chillers 1.30
<500
> 500 1.25

Authority Ministry of Electricity and Water Ministry of Electricity and Water QSASO

60 QUICK SELECTION GUIDE


HVAC Formulae and Conversions
Weights and Measures Commonly Used HVAC Formulae and Conversions

QUICK SELECTION GUIDE 61


62 QUICK SELECTION GUIDE
UAE GCC Regional
DUBAI ABU DHABI QATAR, KUWAIT,

Ziad Awad Andrew Granville Mohamed Tarek Hajeh Mohamed Fathy Alazab Utpal Joshi
DX, VRV DX, VRV VRV, DX Consulting Sales DX, VRV
GSM: +971 52 945 4021 GSM: +971 50 899 2350 GSM: +971 52 741 8739 GSM: +974 55 576 619 GSM: +971 50 557 8464
E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected] E-mail: [email protected]

Khurram Nasir
Sharique Hasan Chiller & Air Side Ramesh Veluchamy
Chiller & Air Side GSM: +971 52 742 3900 Chiller & Air Side
GSM: +971 56 644 1905 E-mail: [email protected] GSM: +971 52 741 9428
E-mail: [email protected] E-mail: [email protected]

DAIKIN MIDDLE EAST AND AFRICA FZE


The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Middle East and Africa FZE has compiled
the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for
particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Middle
P.O. Box 18674, Jebel Ali Free Zone, Dubai, UAE East and Africa FZE explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation
of this publication. All content is copyrighted by Daikin Middle East and Africa FZE.
Tel: +971 (0) 4 815 9300, Fax: +971 (0) 4 815 9311
Email: [email protected]

www.daikinmea.com DMEA 17-070 UAE