0% found this document useful (0 votes)
170 views6 pages

Da 7100

This document provides instructions for a breath alcohol tester. It has a fuel cell sensor, displays results on a 4-digit LCD screen, and automatically powers off. The instructions explain how to insert batteries, use mouthpieces for each person, and perform a breath test by blowing for 5 seconds. Test results show estimated blood alcohol content (BAC) in percentages or milligrams per liter. The device must be used between 5-40 degrees C and calibrated every 12 months or 500 tests. It has a 1-year warranty or 500 tests, whichever comes first.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
170 views6 pages

Da 7100

This document provides instructions for a breath alcohol tester. It has a fuel cell sensor, displays results on a 4-digit LCD screen, and automatically powers off. The instructions explain how to insert batteries, use mouthpieces for each person, and perform a breath test by blowing for 5 seconds. Test results show estimated blood alcohol content (BAC) in percentages or milligrams per liter. The device must be used between 5-40 degrees C and calibrated every 12 months or 500 tests. It has a 1-year warranty or 500 tests, whichever comes first.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Breath Alcohol Tester

Fuel Cell Sensor


Personal & professional use alcohol tester

DA-7100
Instruction
Manual
Fuel cell accuracy
4-digit LCD display with a backlit
Automatic power-off
Low battery checking and indication
Flow check technology

Please read the user's manual carefully before use.


Important safety information

Before using the alcohol tester, read all instruction manual


carefully and practice the test.
Maintenance and calibration should be performed by experts.
Test should be performed after 20 minutes after eating, drinking
or smoking, if failure to wait 20 minutes may result in invalid
results or incorrect results.
Residual alcohol in the mouth can distort the measurement.
Aromatic drinks or mouth sprays containing alcohol can interfere
with measurements. In this case, wait for 20 minutes or rinse the
mouth with pure water.
Do not permit to blow cigarette smoke into the tester which may
damage the sensor.
Do not drink and drive, even small amount of alcohol can result
in driving impairment.
Recommended to use calibration service every 12 months or
after 500 times tests.
Do not use this device as a tool to determine "drink and drive".
The manufacturer and the sellers will not take any legal
responsibility for the test results.
When not used for a long time, keep the device after taking out the
batteries. In case of testing after long-term storage, there might
be high tolerance of test results for the first 3 tests.
Replace the batteries when the battery indicator icon reaches
empty for the accuracy reason.
In case the measured value is higher than 0.1%BAC and you try
again without interval, then warm up time might be delayed.
Perform a test within the operating temperature, which is
specified in the instruction manual.
Introduction
Thank you for purchasing our breathalyzer, ALCOFIND DA-7100 which is
a personal & professional use alcohol tester with extremely high-reliability.
It can be used in the hospital, school and many other industrial fields.
It measures estimated B.A.C(Blood Alcohol Content) in human breath
by means of a fuel cell sensor which is high durable sensors and
providing accurate breath alcohol results.
Contents
Digital Breathalyzer
ALCOFIND DA-7100
Two AAA size batteries
DA-7100

6 (six) mouthpieces
Carrying case
Hand strap
User's manual

Name of each part


1. Mouthpiece
2. Mouthpiece slot
3. Display
4. Power & Start button <Front> <Back>
5. Battery cover

Preparation
Install two AAA batteries in the battery compartment by paying attention
to the battery polarity.

Gently pull the cover down

Two AAA batteries (1.5V Alkaline)


Insert a mouthpiece into the port on the side of the alcohol tester.
Ensure whether it is securely fit or not.
A new mouthpieces is to be used for every person tested.

Insert a mouthpiece into


the port gently!

Do not permit to blow cigarette smoke into the tester.

Performing the measurement


Press the power button
The total number of test performed will be displayed
briefly and start countdown.
When the countdown reaches zero with a double beep sound,
three dashes ( ) will be displayed and "START" will flash.
Take a deep breath and blow the mouthpiece for five seconds
until there is a double beep sound.
When the sampling was successful, LCD outer lines will be
turning along the edge of LCD as you can see the picture.

After a few seconds(depending on the alcohol level), the


estimated BAC(Blood Alcohol Concentration) will be displayed.
The value will flash for several seconds.
If you want to test again, press the start button to restart the
countdown cycle.

The tester automatically will be turned off after


15~20 seconds.
Wait at least 20 minutes after eating, drinking or smoking before measurement.
Display message & Problem-solving guide

MESSAGE WHAT IT MEANS ACTION


Full battery None required.
Empty battery : Warns when
battery is low. The unit can be Replace new batteries.
operated but recommended to change
new batteries for correct result!
If the LCD displays "BAt", Replace new batteries
the unit cannot operate. immediately.

If the sampling volume is too Press button again to


low or not sufficiently blow. repeat the measurement.
If there is no breath sample blown Press button to restart
within 30 seconds, the LCD will the countdown cycle and
display "OUT". retest.
If the unit is powered on beyond the Repeat the test after the unit
acceptable temperature range(5~45 C has reached a temperature
or 41~113 F) the unit will display it. within the operation range.

Technical specifications
0.000 ~ 0.500%BAC
Indication of B.A.C. 0.00 ~ 5.00
0.00 ~ 2.50mg/l
+/- 0.005%BAC at 0.1%BAC at 25 C
Accuracy +/- 0.05 at 1.0 at 25 C
+/- 0.025mg/l at 0.50mg/l at 25 C
Within 15 seconds at 0.50g/l( )
Warm up time
warm up time may vary depending on the BAC measured.
Sensor Fuel cell sensor
Power supply Two AAA size alkaline batteries
Battery Life Approx. 1000 tests
Dimensions(WxHxD) 48mm x 120mm x 20mm
Weight 93g including batteries
Calibration every 12 months or after 500 tests
Operating temperature 5 ~ 40 C
The specifications are subject to change without prior notice for functional improvement.
Warranty
The manufacturer warrants the product to be free from defects in
workmanship or material (excluding calibration) under normal use either
for 1(one) year from the date of purchase or 500 breath tests whichever
comes earlier.
The manufacturer's obligation under this warranty is limited to replacing,
adjusting or repairing the unit at manufacturer's option, if returned along
with proof of purchase.
For any defects due to natural disaster or customer's negligence, misuse,
reconstruction and repair by unau thorized person, reasonable cost shall be
charged for repair or part replacement.

Customer service
For any questions, after-sales service, product calibration or to purchase
additional mouthpieces, please contact nearest distributor.

Distributor :

You might also like