GVS - KNX Smart Touch V50s - UI - V1.2 - 20221228 - EN
GVS - KNX Smart Touch V50s - UI - V1.2 - 20221228 - EN
Chapter 1 Introduction
This document is for the UI description of the KNX Smart Touch V50s. As an appendix of this product, it is
necessary to understand the UI function by the relevant description in the manual of this product. For example,
users need to configure specific parameters for the UI interface to be presented. Therefore, please refer carefully
to the relevant documents and function description before using the product.
Chapter 2 UI Description
This chapter mainly introduces the interactive application of each function interface of this product in detail.
Sections as follow are mainly explained the UI of V50s vertical screen, the operation of horizontal you can
1
K-BUS® KNX/EIB KNX Smart Touch V50s
②
①
④
③ ⑤
⑥
Fig.2.1 Fig.2.2
Fig.2.3 Fig.2.6
Fig.2.4 Fig.2.7
Fig.2.5 Fig.2.8
② This icon is the setting icon, enter the setting page, see section 2.11 for details by
touching this icon;
2
K-BUS® KNX/EIB KNX Smart Touch V50s
The date and time can be modified on the setting page, or through the bus, see details in section 2.11.
④ When external temperature is configured, there is an "E" at the upper right corner of the
icon; When internal temperature is configured, there is no "E" at the upper right corner of the
When device is power on, external sensor occurs fault and the internal sensor display is not enabled, if there
is no receiving the temperature feedback at this time, no temperature value to display; while if normal usage after
a period time before the external senor occurs fault, display the last time receiving detection value.
But external sensor occurs fault and the internal sensor display is enabled, display the detection value of
internal sensor. Note: if internal sensor also occurs fault, display “20℃” or “-68℉”, as shown as Fig.2.5,
Fig.2.8.
When temperature unit is set to degrees Celsius (℃) through ETS, temperature display as shown in Fig.2.1.
⑤ This area displays humidity, and the data is obtained from the external sensor;
When humidity from the external sensor feedback is received, interface as shown in Fig.2.7. When no
humidity from the external sensor feedback is received, there is no humidity shown in the interface .
⑥ This area displays home page name, user can define the name by configuring the
Home page navigation as shown in Fig.2.1, the number of home page navigation can be configured up to 5,
to quickly jump to a function page or directly manipulate a function icon (switch, switch/dimming, blind, value
send, scene).
If the association function of the shortcut, shown on the home page interface, link to a function page, its page
icon can be configured in the ETS, and its description is the page description of the linked function page, as
If the association function link to an icon function on a function page (such as leave mode), the display effect
3
K-BUS® KNX/EIB KNX Smart Touch V50s
is consistent with the icon configuration when the UI style of multifunction is selected grid view, as shown as
Fig.2.1, Fig.2.2.5. If it is selected list view, home page is grid view, while the function page is shown as list view,
If the linked page or icon does not exist, the corresponding location will be empty.
⑨ ⑩
① ②
③ ④
⑤ ⑥
⑦ ⑧
4
K-BUS® KNX/EIB KNX Smart Touch V50s
The interactive interface style of multifunction page is shown in Fig.2.2.1-Fig.2.2.10 above. The interface
style, and the number of icons displayed, with a maximum of 8, can be set through parameters setting. The effects
①~⑧:The serial number marked in Fig.2.2.1 above is consistent with the sequence number
of the function icon in the ETS, that is, the placement principle of the function icon is from left to
When multifunction icon is grid view, the function status is indicated by the icon in the block. For example,
in Fig.2.2.1, the icon on indicates the lamp turn on and the icon off indicates the lamp turn off; in Fig.2.2.2, the
icon block and icon on indicates the lamp turn on, and the icon block and icon off indicates the lamp turn off; in
Fig.2.2.2, if the function is dimming, the upper right corner of the block displays the current brightness, which is
from the output brightness feedback of the dimmer actuator. Except the light/off status display, the icon of value
sending will shake when being manipulate and the icon of blind will show the position status; in Fig.2.2.3, the
interface can set to display no icon but only text by parameter configuration, block on indicates the lamp turn on
⑨ This area is the page description identification of the multifunction page, user can define
⑩ This icon is the main page icon, return to the home page by touching this icon;
When the multifunction icons are configured as list view and display in the list, as shown as
Fig.2.2.7~2.2.10
5
K-BUS® KNX/EIB KNX Smart Touch V50s
⑪ The status of button icon indicate the corresponding function, is suitable for switch,
⑫ Enter the control interface of the sub-function of dimming function by touching this area,
When only brightness dimming, a slider is displayed on the right to adjust the brightness in
When support to brightness adjustment, the brightness feedback will be shown below the
function description.
⑬ The function of this area is value sending, the icon wobbles according to when short
⑭ Enter the control interface of the sub-function of curtain function by touching this left area,
(1) When support to position adjustment, the position feedback will be shown below the
function description.
6
K-BUS® KNX/EIB KNX Smart Touch V50s
Fig.2.2.1.1
Fig.2.2.1.2
Fig.2.2.1.3
Fig.2.2.1.4
The status of the switch function in different UI styles is shown in the figure above.
(1) In Fig.2.2.1.1, the icon on (shown in the right figure) indicates the lamp to turn on and the icon off
(2) In Fig.2.2.1.2, the block and icon on (shown in the right figure) indicates the lamp to turn on, the block
and icon off (shown in the left figure) indicates the lamp to turn off;
(3) In Fig.2.2.1.3, the block on (shown in the right figure) indicates the lamp to turn on, and the block off
(4) In Fig.2.2.1.4, the switch button icon on (shown in the right figure) indicates the lamp to turn on, and the
switch button icon off (shown in the left figure) indicates the lamp to turn off. At the same time, it can be updated
7
K-BUS® KNX/EIB KNX Smart Touch V50s
brightness+colour temperature dimming function. Their UI styles are similar to the switch function, as Fig.2.2.1.1,
Fig.2.2.1.2, Fig.2.2.1.3 and Fig.2.2.1.4 shown above, the difference is that the current brightness status is
displayed at the same time on the icon, which needs to receive brightness feedback from the dimming actuator
Relative dimming has no individual control interface, dimming via operate the icon. Short press to switch
on/off, icon on indicates the lamp to turn on, icon off indicates the lamp to turn off. Long press to send the
command to increase or decrease 100% brightness, long press then release to send the command to stop dimming.
②
① ③
⑥
⑧ ⑨
④ ⑤
② This area displays the identification of page description, format as: page description of
8
K-BUS® KNX/EIB KNX Smart Touch V50s
④ Adjust the brightness in the way of relative dimming by touching this icon, long press to
send 100%, long release to send stop dimming command; Short press only to dim 100%;
⑤ Adjust the brightness in the way of relative dimming by touching this icon, long press to
send 0%, long release to send stop dimming command; Short press only to dim 0%;
At the same time, the slider status can also be updated according to the brightness feedback received from the
bus.
Colour temperature control interface shown as Fig.2.2.2.3, by sliding the ring slider⑦ or touching the
icon⑧ and icon⑨ to control the colour temperature of lamp, the adjustment range for each touch of icon⑧ or
icon⑨ is 100K. The maximum range for colour temperature adjustment is 2000~7000K, the range can be
modified by the parameters. The ring slider⑦ status can also be updated according to the colour temperature
At the same time, the slider status can also be updated according to the brightness feedback received from the
bus.
By touching the icon, the device will send the corresponding telegram to the bus, and the icon will shake. If
long operation is set, the long/ short operation of the icon will send the corresponding setting value.When in short
press operation, the control telegram will be trigger when touch the icon, and if the long operation is enabled,
only after the fixed time of the long operation (the default is 500ms) will the control telegram be triggered.
9
K-BUS® KNX/EIB KNX Smart Touch V50s
Blind function including 5 types: Curtain position, Roller Blind position, Venetian Blinds position and slat,
Curtain step/move, Roller blind step/move. Besides, in the UI interface, the current position status of the curtain is
displayed on the icons of all types of blinds, which needs to be accurately displayed based on the position of the
blinds that is fed back from the curtain actuator received on the bus.
Curtain position
This type is for Curtain position controlling, supporting to adjust the position of curtain by sliding the slider
in the form of percentage as well as opening, closing and stop moving by manipulating three controlling buttons.
① ③
⑥
④ ⑤
Fig.2.2.4.1
② This area displays the identification of the page description, format as: page description
10
K-BUS® KNX/EIB KNX Smart Touch V50s
④ Short press the icon to open curtain, long press to stop moving;
⑤ Short press the icon to close curtain, long press to stop moving;
⑦ This icon is the slider icon, adjust the position of curtain in the form of percentage by
⑧ This icon displays the simulation of curtain position, display the current curtain position
By sliding the slider⑦ to adjust the position of blind in the form of percentage, during the sliding, icon⑧
At the same time, the status of slider⑦ and icon⑧ will also update according to the curtain position status
This type is for Roller Blind position controlling, supporting to adjust the position of blinds by sliding the
slider in the form of percentage as well as moving up, moving down and stop moving by manipulating three
controlling buttons. The control interface of Roller Blind position function is shown in Fig. 2.2.4.2 below.
① ③
⑥
④ ⑤
Fig.2.2.4.2
11
K-BUS® KNX/EIB KNX Smart Touch V50s
② This area displays the identification of the page description, format as: page description
④ Short press the icon to run up blind, long press to stop moving;
⑤ Short press the icon to run down blind, long press to stop moving;
⑦ This icon is the slider icon, adjust the position of blind in the form of percentage by sliding
this slider;
⑧ This icon displays the simulation of blind position, display the current blind position in
By sliding the slider⑦ to adjust the position of blind in the form of percentage, during the sliding, icon⑧
At the same time, the status of slider⑦ and icon⑧ will also be updated according to the blind position
12
K-BUS® KNX/EIB KNX Smart Touch V50s
This type is for Venetian Blinds position and slat controlling, supporting to adjust the position of blind and
angle of louver by sliding the slider in the form of percentage as well as to run up the blind, run down down the
blind and stop the blind from moving by manipulating three controlling buttons. The control interface of Venetian
① ③
②
⑧ ⑩
⑦ ⑨
⑥
④ ⑤
Fig.2.2.4.3
② This area displays the identification of the page description, format as: page description
④ Short press the icon to run up blind, long press to stop moving/adjust the blind angle up;
⑤ Short press the icon to run down blind, long press to stop moving/adjust the blind angle
down;
⑦ This icon is the slider icon, adjust the position of blind in the form of percentage by
13
K-BUS® KNX/EIB KNX Smart Touch V50s
⑧ This icon displays the simulation of blind position, display the current blind position in
By sliding the slider⑦ to adjust the position of blind in the form of percentage, during the sliding, icon⑧
⑨ This icon is the slider icon of louver angle, adjust the position of blind in the form of
⑩ This icon displays the simulation of louver angle, display the current blind slat in the form
By sliding the slider⑨ to adjust the position of blind in the form of percentage, during the sliding, icon⑩
At the same time, the status of slider⑦, slider⑨, icon⑧ and icon⑩ will also be updated according to the
Curtain step/move
This type is for Curtain step/move controlling, supports opening, closing and stop moving by manipulating
three controlling buttons. The control interface of Curtain step/move function is shown in Fig.2.2.4.4 below.
① ③
⑥
④ ⑤
Fig.2.2.4.4
14
K-BUS® KNX/EIB KNX Smart Touch V50s
② This area displays the identification of the page description, format as: page description
④ Short press the icon to open curtain, long press to stop moving;
⑤ Short press the icon to close curtain, long press to stop moving;
Control the blind by touching icon④, icon⑤ and icon⑥, during operation, icon⑦ will dynamically
At the same time, the status of icon⑦ will also update according to the curtain status feedback received from
the bus.
15
K-BUS® KNX/EIB KNX Smart Touch V50s
This type is for Roller blind step/move controlling, supports opening, closing and stop moving by
manipulating three controlling buttons. The control interface of Roller blind step/move function is shown in Fig.
2.2.4.5 below.
① ③
⑥
④ ⑤
Fig.2.2.4.5
② This area displays the identification of the page description, format as: page description
④ Short press the icon to run up blind, long press to stop moving;
⑤ Short press the icon to run down blind, long press to stop moving;
Control the blind by touching icon④, icon⑤ and icon⑥, during operation, icon⑦ will dynamically
16
K-BUS® KNX/EIB KNX Smart Touch V50s
At the same time, the status of icon⑦ will also update according to the blind status feedback received from
the bus.
By touching the icon, the device sends the corresponding scene telegram to the bus. If long operation is set,
short pressing the icon for the scene call, long pressing the icon for the scene store. The icon status is updated
according to the scene currently called, and if the scene is saved, the icon will shake (horizontally).
Switch indicator is only used to display the on/off status of device, the device will send corresponding status
Telegram to bus, and the icon status will be updated according to the received telegram, the effect is similar
to switch function.
17
K-BUS® KNX/EIB KNX Smart Touch V50s
③
②
⑥
⑤
⑦
⑧
⑨
The initial state of power is defined according to the parameters, and it may also be in an uncertain state.
When ON, the interface can be operated; when OFF, the other icons are not operable except the ON/OFF button.
18
K-BUS® KNX/EIB KNX Smart Touch V50s
② This area displays the page description identification of RTC function page, user can
The colour of ring slider is to display according to current control mode, display red when heating mode as
Temperature unit is ℃, the ring slider styles can be optional 5~40℃, 16~32℃ or 19~25℃; When unit is ℉,
it can be optional 41~104℉, 61~90℉ or 66~77℉. Choose the style according to threshold value range configured
in ETS.
Adjusting the temperature by sliding the ring slider④ or touching the icon⑤ and icon⑥. For each
touching of icon⑤ and icon⑥, the adjustment range is 0.5 degrees. When the setting temperature unit is set to
degrees Celsius(℃), as shown in 2.3.1, adjustment range of the setting temperature is 5~40℃ by default; when
the setting temperature unit is set to Fahrenheit(℉), the current temperature value will automatically convert to
Fahrenheit value, as shown in Fig.2.3.3, adjustment range of the setting temperature is 41~104℉ by default. The
Ambient temperature is displayed according to the parameter configuration. Temperature detected by internal
sensor or external sensor can be displayed through configuration. When internal and external sensor both occur
Display ambient temperature or setpoint temperature on the screen, which is defined via ETS; Auto change to
setpoint temperature when operation temperature decrease/increase, no action after 3 seconds, return to ambient
temperature.
⑦ This icon is the Heating/Cooling icon, for heating and cooling switching;
Control mode of RTC is configured by ETS, when it is “Heating and Cooling”, you can change mode on the
19
K-BUS® KNX/EIB KNX Smart Touch V50s
⑧ Enter the fan speed setting by touching this area, and will pop up a sub-window shown as
Fig.2.3.4;
This window shows up to 5 options of fan speed: Auto, OFF, Low, Medium and High. Select one of these
options then touch the area outside the sub-window to return the previous level function page. Under the auto fan
speed, there would be no specific fan speed shown on the interface; the auto fan speed can be disable or enable by
parameter configuration, when disable, there would be no Auto option on the window.
Fan speed adjustment of RTC set to be disable or enable through parameter configuration. When disable,
there would be no fan speed function shown as Fig.2.3.1 on the interface; when enable, fan speed can be adjusted.
⑨ Enter the mode setting by touching this area, and will pop up a sub-window shown as
figure 2.3.5.
This window shows up to 4 options of mode: Comfort, Standby, Economy and Protection, select one of these
options then touch the area outside the sub-window to return to the previous level function page.
Operation mode of RTC set to be disable or enable through parameter configuration. When disable, there
would be no mode option as shown as Fig.2.3.1 on the interface; when enable, operation mode can be selected.
Remarks:
When the setting temperature for operation mode is configured as relative adjustment, the adjustment
of setting temperature under the protection mode only acts on the protection mode, for other modes,
relative change of temperature adjustment are able to act on all modes (except the setting temperature of
protection mode).
When the setting temperature for operation mode is configured as absolute adjustment, the
When change to protection mode, the ring slider displays gray, the ring slider and increase/decrease icon all
can not be operated, that is, you can not change setpoint temperature at this time, as shown as below.
20
K-BUS® KNX/EIB KNX Smart Touch V50s
Icon⑩ on indicates timer turn on; icon⑩ off indicates timer turn off. Timer function can be enabled via the
parameter configuration. When timer function is disabled, there would be no timer icon as shown as Fig.2.3.1 on
Only support to one timer. Power on/off or call the scene function that configured by RTC, it can not turn off
timer function.
Note: in the off status, if timer function is set to send a setpoint temperature, the temperature is sent
Long press to enter the timer configuration interface, pup-up the window as shown as Fig.2.3.6. You can
select set the week, hour, minute and other RTC operation. Touch the area outside the sub-window to return to the
⑪ This area can choose from Monday to Sunday of the week for timing;
⑫ Sliding the number to choose the date and time for timing;
⑬ Sliding to choose the RTC status for timing, you can choose on, off, operation mode or
setpoint temperature;
If RTC function is linked to home page, display setpoint temperature on the top right corner of corresponding
icon in the home page, and the colour is according to control mode: Heating mode-red; cooling mode-blue. When
21
K-BUS® KNX/EIB KNX Smart Touch V50s
②
③
⑤
⑥
⑦
⑧
⑨
① This icon is ON/OFF button for the on/off of Air Conditioner control;
When ON, the interface can be operated; when OFF, the other icons are not operable except the ON/OFF
button. The status of power ON mode, Fan speed, and setpoint temperature is the status before power OFF. The
22
K-BUS® KNX/EIB KNX Smart Touch V50s
Air Conditioner control interface will recover to the status before voltage failure.
② This area displays the page description identification of Air-Conditioner control, user can
Adjusting the temperature by sliding the ring slider④ or touching the icon⑤ and icon⑥. For each touching
of icon⑤and icon⑥, the adjustment range is 1.0 degrees. When the setting temperature unit is set to degrees
Celsius(℃), as shown in Fig.2.4.1, adjustment range of the setting temperature is 16~32℃ by default; when the
setting temperature unit is set to Fahrenheit(℉), the current temperature value will automatically convert to
Fahrenheit value, as shown in Fig.2.4.2, adjustment range of the setting temperature is 61~90℉ by default. The
The ambient temperature is displayed according to the parameter configuration. Temperature detected by
internal sensor or external sensor can be displayed through configuration. When internal and external sensor both
Display ambient temperature or setpoint temperature on the screen, which is defined via ETS; Auto change to
setpoint temperature when operation temperature decrease/increase, no action after 3 seconds, return to ambient
temperature.
⑦ Enter to the vanes setting by touching this tile, and will pop up a sub-window shown as
Fig.2.4.3;
Vanes setting is used to switch the working mode of fan direction, and there are two modes: fixed and swing.
Select one of these options then touch the area outside the sub-window to return to the previous level function
page.
Under fixed vanes position, select one of the 5 options (#1, #2, #3, #4, #5) for vanes position, for instance,
select #1, interface as shown in Fig.2.4.3, then touch the area outside the sub-window to return the previous level
23
K-BUS® KNX/EIB KNX Smart Touch V50s
function page, the position selected will be shown on the function page, as shown in Fig.2.4.1. For vanes swing,
because vanes position change all the time, there would be no fixed position, only display character “Swing” on
the interface.
Vanes swing function set to be disable or enable by parameter configuration. When disable, there will be no
vanes fixed/swing item shown on the interface, as shown in Fig.2.4.1; when enable, vanes position can be
adjusted.
⑧ Enter the mode setting by touching this area, and will pop up a sub-window shown as Fig.
2.4.4;
This dialogue window shows up to 5 options of Air Conditioner mode: Auto, Heating, Cooling,
Dehumidification and Fan. Select one of these options then touch the area outside the sub-window to return to the
Each mode set to be disabled or enabled independently by the parameters configuration. When a mode is
disabled, there will be no corresponding item is shown on the interface; when enabled, support to operate the
mode.
⑨ Enter the fan speed setting by touching this icon, and will pop up a sub-window shown as
Fig.2.4.5;
This dialogue window shows up to 4 options of fan speed mode: Auto, Low, Medium and High. Select one of
these options then touch the area outside the dialogue sub-window to return to the previous level function page.
Icon⑩ on indicates timer turn on; icon⑩ off indicates timer turn off. Timer function can be enabled via the
parameter configuration. When timer function is disabled, there would be no timer icon as shown as Fig.2.4.1 on
Only support to one timer. Power on/off or call the scene function that configured by Air Condition, it can not
Note: in the off status, if timer function is set to send a setpoint temperature, the temperature is sent
24
K-BUS® KNX/EIB KNX Smart Touch V50s
Long press to enter the timer configuration interface, pup-up the window as shown as Fig.2.4.6. You can
select set the week, hour, minute and other Air conditioner operation. Touch the area outside the sub-window to
⑪ This area can choose from Monday to Sunday of the week for timing;
⑫ Sliding the number to choose the date and time for timing;
⑬ Sliding to choose the RTC status for timing, you can choose on, off, mode or setpoint
temperature;
If Air Conditioner function is linked to home page, display setpoint temperature on the top right corner of
corresponding icon in the home page, and the colour is according to the mode: Heating mode-red; cooling
mode-blue, dehumidification-yellow, fan-green. When Air Conditioner is power off, it displayed “OFF”
⑥
⑤
⑨
⑧
⑩
⑦
⑪
① This icon is ON/OFF button for the on/off of Floor Heating control;
25
K-BUS® KNX/EIB KNX Smart Touch V50s
When ON, the interface can be operated; when OFF, the other icons are not operable except the ON/OFF
② This area displays the page description identification of AC control, user can define the
Temperature unit is ℃, the ring slider styles can be optional 16~32℃ or 19~25℃; When unit is ℉, it can be
optional 61~90℉ or 66~77℉. Choose the style according to threshold value range configured in ETS.
Adjusting the temperature by sliding the ring slider④ or touching the icon⑤ and icon⑥. For each
touching of icon⑤ and icon⑥, the adjustment range is 0.5 degrees. When the setting temperature unit is set to
degrees Celsius(℃), as shown in Fig.2.5.1, adjustment range of the setting temperature is 16~32℃ by default;
when the setting temperature unit is set to Fahrenheit(℉), the current temperature value will automatically convert
to Fahrenheit value, as shown in Fig.2.5.2, adjustment range of the setting temperature is 61~90℉ by default. The
The ambient temperature is displayed according to the parameter configuration. Temperature detected by
internal sensor or external sensor can be displayed through configuration. When internal and external sensor both
Display ambient temperature or setpoint temperature on the screen, which is defined via ETS; Auto change to
setpoint temperature when operation temperature decrease/increase, no action after 3 seconds, return to ambient
temperature.
Icon⑦ on indicates the heating valve to be open; icon⑦ off indicates the heating valve to stop heating, at
Floor heating compares the setting temperature with actual temperature of current environment to define
26
K-BUS® KNX/EIB KNX Smart Touch V50s
control value according to 2-point control or PI control mode, so that realizes the automatic opening or closing of
Icon⑧ on indicates timer turn on; icon⑧ off indicates timer turn off. Timer function can be enabled via the
parameter configuration. When timer function is disabled, there would be no timer icon as shown as Fig.2.5.1 on
Only support to one timer. Power on/off or call the scene function that configured by Floor heating, it can not
Note: In the off status, if timer function is set to send a setpoint temperature, the temperature is sent
Long press to enter the timer configuration interface, pup-up the window as shown as Fig.2.5.3. You can
select set the week, hour, minute and other Floor heating operation. Touch the area outside the sub-window to
⑪ This area can choose from Monday to Sunday of the week for timing;
⑫ Sliding the number to choose the date and time for timing;
⑬ Sliding to choose the RTC status for timing, you can choose on, off or setpoint
temperature;
If Floor heating function is linked to home page, display setpoint temperature on the top right corner of
corresponding icon in the home page, and the colour is displayed to red. When Floor heating is power off, it
displayed “OFF”.
27
K-BUS® KNX/EIB KNX Smart Touch V50s
③
②
④
⑨
⑤
⑩
⑦
⑪
⑧
① This icon is ON/OFF button for the on/off of Ventilation System control;
The initial state of power is defined according to the parameters, and it may also be in an uncertain state.
When ON, the interface can be operated; when OFF, the other icons are not operable except the ON/OFF button.
② This area displays the page description identification of Ventilation System, user can
Only when auto fan speed control of ventilation system is enable would this interface display, as shown in
CO2 concentration as shown in Fig.2.6.1, according to the value received from the bus, range 0~4000ppm; if
the data exceed 4000ppm, then the interface will display 4000ppm.
28
K-BUS® KNX/EIB KNX Smart Touch V50s
PM2.5 concentration as shown in Fig.2.6.2, according to the value received from the bus, range 0~999ug/m3;
if the data exceed 999ug/m3, then the interface will display 999ug/m3.
There is up to 4 options for fan speed mode:Auto, Low, Medium and High. When fan speed auto control is
enable, auto fan speed adjustment will be displayed on the interface, shown as Fig.2.6.1 and Fig.2.6.2. Whether
fan speed auto control is enable or not is configured through parameter configuration.
When fan speed auto control is enable, fan speed level is calculated according to CO2 or PM2.5
concentration. The interface displays only the auto icon, but no specific fan speed level.
Whether the filter timer counter function is enable or not is configured through parameter configuration.
When disable, there will be no display of filter timer counter function on the interface as shown in Fig.2.6.1; when
enable, icon⑦ will be colorful after ventilation system ON, the remaining evaluation value will be displayed next
to it. The value will be updated according to the use time, which will be updated through the bus.
The service life of the filter set by the parameter configuration. When the filter time reaches to the parameter
setting value, the alarm state can be issued through the bus, and the remaining filter timer value can be displayed
to be 0%. When touch icon⑦, the filter time can be reset, as shown in Fig.2.6.4 below. After clicking “Confirm”,
Fig.2.6.4
⑧ This is the heat recovery icon, used to turn on or off heat recovery function;
Whether heat recovery function of ventilation system is enable or not is configured through parameter
configuration. When disable, there will be no display of heat recovery function on the interface as shown in Fig.
2.6.1; when enable, heat recovery function is turned on by default when ventilation system is ON, and the heat
recovery function can be turned on or off by touching icon⑧. The icon on indicates that the heat recovery is on;
the icon off indicates that the heat recovery is off. In addition, heat recovery function can be turned on or off
through the bus. And there would be no responding after enable heat recovery function.
29
K-BUS® KNX/EIB KNX Smart Touch V50s
When fan speed is not configured as auto, as shown in Fig.2.6.3, by touching icon⑩ and icon⑪ to adjust
fan speed; for each touch of icon⑩ and icon⑪ to adjust one level, there are 3 modes of fan speed: Low, Medium
and High. At this time, the adjustment is manually, not automatically according to the concentration of CO2 or
PM2.5.
There are 3 control types of RGB dimming function: RGB, RGBW, RGBCW, are configured through
parameter configuration. Among them, RGB is suitable for adjusting RGB lamp; RGBW is suitable for controlling
RGBW strip; RGBCW is suitable for RGB lamp, brightness and colour temperature control.
②
③
⑥
⑦
①
30
K-BUS® KNX/EIB KNX Smart Touch V50s
⑨
⑩
Fig.2.7.4
Touch this icon to switch on/off, the RGB lamp is turned on or turn off;
When touch the icon to switch off, the status of different RGB lamps are as follow:
(1)RGB: Colour brightness value (ring slider④) is updated to 0, and the colour palette⑤ remains the same;
(2)RGBW: Colour brightness value (ring slider④) and white brightness value(slider⑥) are updated to 0,
(3)RGBCW: Colour brightness value (ring slider④) and colour temperature brightness value(slider⑥) are
updated to 0, and the colour palette⑤ and colour temperature value(ring slider⑧) remain the same;
When RGB or W colour value is not 0 (i. e., ring slider④ is not slid to the left bottom or slider⑥ is not slid
② This area displays the page description identification of RGB dimming function page,
④ This ring slider is used to adjust the colour shade of the RGB lamp;
When RGB dimming function is configured as RGB, function page interface as shown in Fig.2.7.1, sliding
ring slider④ to adjust the colour shade of RGB lamp, when ring slider④ is slid to the left bottom, RGB lamp is
31
K-BUS® KNX/EIB KNX Smart Touch V50s
completely OFF, at this time, the button① become gray, and no reaction when operate the colour palette⑤.
When RGB value of ring slider④ is not 0, the circular colour palette is for selecting colour, when touch the
button①, RGB lamp off, and ring slider④ automatically slides to the left bottom, button① become gray.
When RGB dimming function is configured as RGBW, function page interface as shown in Fig.2.7.2, RGBW
function page interface is similar to RGB function page interface, which is no longer described herein.
⑥ This slider for adjusting the brightness of white light, sliding the slider to adjust the
When RGB dimming is configured as RGBW, RGBCW, adjust the white brightness by sliding slider⑥,
when it is slid to the left bottom, operation is similar to ring slider④, not explain again here.
When RGB dimming is configured as RGBCW, function page interface is similar to RGB but more a
Colour temperature control interface shown as Fig.2.7.4, by sliding the ring slider⑧ or touching the icon⑨
and icon⑩ to control the colour temperature of RGB lamp, the adjustment range for each touch of icon⑨ or
icon⑩ is 100K. After finishing the adjustment, touch the area outside the sub-window to return to the previous
level function page, as shown in Fig.2.7.3. The maximum adjustable rang of colour temperature is limited in
32
K-BUS® KNX/EIB KNX Smart Touch V50s
Fig.2.8.1
① This area displays the page description identification of the Energy Metering Display
② This area displays the identification of data description, user can define the description
through ETS;
Energy Metering Display interface shown as Fig.2.8.1, current, voltage, power and energy consumption can
be displayed through parameter configuration. There are up to 8 items displayed in the interface, these data can be
updated and displayed through the bus, such as Switch Actuator with Current Detection can provide the present
33
K-BUS® KNX/EIB KNX Smart Touch V50s
① This area displays the page description identification of Air Quality Display function
page;
③ This display area is the air quality parameter display list, can be configured through
parameter configuration;
Temperature, humidity, PM2.5, PM10, CO2, VOC, AQI, brightness, wind speed and rain status can displayed
④ This ring strip is used for displaying the air quality parameter value;
Touch one of the items in the display list at the bottom of the interface, the pointer on the ring strip④ will
point to the corresponding scale, such as Fig.2.9.1 above is the display effect of temperature, Fig.2.9.2 is the
display effect of humidity, Fig.2.9.3 is the display effect of CO2 and Fig.2.9.4 is the display effect of AQI.
You can see the display range of the corresponding item on the interface ring strip④:
Temperature: -40~99 ℃
Humidity: 0~100 %
PM2.5: 0~999 ug/m3
PM10: 0~999 ug/m3
34
K-BUS® KNX/EIB KNX Smart Touch V50s
Rain status: only display the status of the ring strip and text description (no rain, the ring strip is off;
The displayed data are usually provided by other external sensors on the system.
② ③
⑪
⑥ ⑦
④ ⑤ ⑫
⑬
⑭
⑨ ⑩
⑧
①
① This icon is ON/OFF button for the power on/off of Audio control;
As shown in Fig.2.10.1, when ON, the interface can be operated; when OFF, the other icons are not operable
② This area displays the page description identification of Background Music function page,
35
K-BUS® KNX/EIB KNX Smart Touch V50s
When adjustment volume is configured to be 1bit type, relative control volume by touching icon④ and
When adjustment volume is configured to be 1bit type, mute function can be enabled via the parameter
configuration. When mute function is disabled, there would be no mute icon as shown as Fig.2.10.1 on the
interface.
⑦ Adjust the volume in the form of percentage by sliding this ring slider;
When adjustment volume is configured to be 1byte type, absolute control volume by sliding slider⑦. The
⑬ Set the play mode to play in list cycle by touching this icon;
⑮ Set the play mode to play in single cycle by touching this icon;
As shown in Fig.2.10.3, select one of these play modes then touch the area outside the sub-window to return
36
K-BUS® KNX/EIB KNX Smart Touch V50s
④ ⑤
⑥ ⑦
⑧ ⑨
⑩
⑪
⑫
⑬
⑭
⑯
⑱
⑰
⑲
⑰
Fig.2.11.4 Fig.2.11.5 Fig.2.11.6
37
K-BUS® KNX/EIB KNX Smart Touch V50s
Click the setting icon in the upper-right corner of the main page to enter the setting page, as shown in
Fig.2.11.1.
② This area displays the page description identification of Setting page, format as: setting|
The sub-interface with the same area format are the same, no longer do the following description.
The interface for setting the cleaning mode countdown as shown in Fig.2.11.2. The time increase/decrease in
every 5 seconds when operating, the minimum setting time is 5s and the maximum is 60s, the default setting time
is 30s; click “Start” to enter the cleaning mode countdown, as shown in Fig.2.11.8, it will return to the setting
The interface for setting the UI language as shown in Fig.2.11.3, support 12 languages, and you can it via
38
K-BUS® KNX/EIB KNX Smart Touch V50s
parameter.
The interface for setting the General parameter as shown in Fig.2.11.4, you can set the proximity sensor, UI
The interface for setting the Data/Time as shown in Fig.2.11.5, slide the number to set the current date and
time.
The interface of system information as shown in Fig.2.11.6, You can view the system information of the
LCD screen, touch screen, KNX SN number, system version, KNX version and program version. (Note: only
when program version is the same as database version in the ETS, the device is allowed to be downloaded
in the ETS. )
The interface for setting the Weekly timer as shown in 2.11.7, the weekly timer needs to be enabled through
parameter configuration. Weekly timer before being configured is not operable. The instructions description is
⑳~㉕.
There are three settings: OFF, Normal and Enhance, indicating the distance near the sensor, “Normal”
distance is approximately 15cm and “Enhance” distance is approximately 30cm. When the device senses the
human body approaching, then wake up the device and enter the operation interface or password interface.
Pop up the window as shown in Fig.2.11.9 when click Dark or Light, each theme has 3 background pictures
⑬ This area displays the physical address of the device, the physical address can be set
39
K-BUS® KNX/EIB KNX Smart Touch V50s
through ETS;
Touch the button icon⑫ on the right to enter or exit the physical address programming mode. In the
programming mode, the device programming indicator light turns red, that is, the colour light strip turns red. After
exiting the programming mode, the colour light strip returns to the normal instruction.
Touch the button icon⑭ on the right to disable or enable the screen-sliding function. If enable, multiple
function pages can be switched by sliding screen. When disable, function pages cannot be switched by sliding left
or right, but entered from home page (if the function pages have linked to home page).
Touch the button icon on the right to disable or enable the vibration function. When enable, the device has a
sense of vibration when operate the screen. When disable, there is no vibration.
⑰ This area is for the touch volume setting, which is used to increase/decrease volume and
By touching icon⑱ and icon⑲ to increase/decrease touch volume, the volume is displayed by the
Finish general parameter setting (indication ⑩~⑲ ), touch the icon (top-left corner) to return to the Setting
page.
40
K-BUS® KNX/EIB KNX Smart Touch V50s
㉓
㉒
㉑
⑳ ㉔
⑳ Manually enable/disable the time function of every day in a week by touching this icon;
Weekly timer is enabled by default if the parameters are configured. If the timer of the day is turned on,
corresponding actions will be performed when the timer is up. Specific timer and actions are configured by
parameters. If timer is not required on the day, manually close it. The button on the right side of the interface is
㉑ By touching the middle position of this area to pop up window as shown in Fig.2.11.11;
This window is for editing the set weekly timer, touch to select Monday~Sunday in a week, slide the number
to select specific timing time. Finish configuration, touch the area of outside the window to return previous
interface.
As shown in Fig.2.11.12, when there is no holiday added, the interface displays “No holiday timing setting,
please add”.
Touch icon㉔, enter the interface as shown in Fig.2.11.14, set the period of holiday, here set up after the start
time and end time of the holiday, click “Confirm” to finish the setting. If the holiday time is repeated when setting,
then will pop up a window as shown in Fig.2.11.15; touch the area outside the window to return to the setting
page.
If it is to be modified or deleted the setting time, touch this time period to the right of the icon ㉕ , then
re-enter Fig.2.11.14 interface, in this period of time to modify or delete, click “Delete” as shown in Fig.2.11.16
pop-up window. In the pop-up window, click “Cancel” to return to the setting page, and click “Confirm” to delete
it. If no modification or deletion is needed, the icon in the upper left corner of the touch interface returns to the
holiday interface.
42
K-BUS® KNX/EIB KNX Smart Touch V50s
2.12.Screen saver
43
K-BUS® KNX/EIB KNX Smart Touch V50s
Screen saver can be set as clock, digital clock with air quality or album that system comes with through ETS
(1) Clock screen-saver shown as Fig.2.12.1, displayed after entering the screen saver. Digital clock shown as
Fig.2.12.2, the type and numbers of air quality information is configured by ETS, which is up to 4 items. The
three default pictures in the program are shown as in Fig.2.12.3, Fig.2.12.4 and Fig.2.12.5. The album can choose
1 or 3 pictures as the screensaver, display the fist picture when the number of pictures is 1; It will automatically
(2) Inserting new pictures through Micro SD card, specific steps are as follow:
Note: ①Only support SDHC card and the format should be FAT32 (if the format is not FAT32, it need to be
formatted as FAT32); ②Only support Micro SD cards with capacity not greater than 32GB.
1.Micro SD card setting: create a new folder named "picture" under the root directory of Micro SD card,
place three pictures in the folder, support pictures with the suffix: jpg, png (Among them, the background colour
Note: ① Replacing pictures according to the name suffix of the new picture corresponding to the original
album number of the system: for example, placing “Album_1_v” in the folder “picture”, it will replace the first
one of the system album; another example as, place “Album_1_v” and “Album_3_v ”, it will replace the first one
② Update pictures: when there is a folder named “picture” in the Micro SD card, and there is a picture in
accordance with valid name and format, then it will update and store (even if the picture is the same as the last
saved).
2.Insert Micro SD card into the device, if Micro SD card meet the above settings, and valid pictures are
detected to be there, then will pop up a request window to confirm update, as shown in Fig.2.12.6;
3.Click “Confirm” to update picture; after upgrade, there will pop up a window of the result, if upgrade is
successful, then reboot the device manually to apply the new picture to the album; if upgrade is failed, click any
area outside the window to return to the page, as shown in Fig.2.12.7, Fig.2.12.8, Fig.2.12.9 and Fig.2.12.10.
(3)Delete the customized picture that has already inserted through Micro SD card, specific steps are as
follow:
When there is a folder named “picture” in the Micro SD card but no picture in accordance with valid name
44
K-BUS® KNX/EIB KNX Smart Touch V50s
and format, there will pop up a window “System resource recovery?”, as shown in Fig.2.12.11, click “Confirm”,
then will delete the customized picture that has already inserted and pop up a window “ Success! please reboot...”,
as shown in Fig.2.12.12, you need to reboot the device manually to recover the original album of the system.
Note: when upgrading, if the single picture is larger than the remaining storage space of the device (the total
size of the device picture storage disc is about 15 MB), the remaining valid pictures shall be stopped updating,
When no operation on the screen and the screen saver set by parameter is over the delay time, screen will
enter the screen saver state; once an operation happened, it will exit screen-saver.
2.13.Password
Enable or disable the password function through parameter configuring, if enable, the interface shown as
Fig.2.13.1, when access setting page, or wake up form the state of screen-saver or screen-off,, you need to input
password to operate. Password only allow 4 digit number, configured by parameter setting.
If set a password for accessing setting page, you can not operate the setting page except for the cleaning
mode and UI language, as shown as Fig.2.13.2, click the locking area then enter the password interface.
① ②
Fig.2.13.1 Fig.2.13.2
45
K-BUS® KNX/EIB KNX Smart Touch V50s
2.14.Panel Lock
Device Locking
User can lock or unlock the operating interface of the device via the bus. After locking, interface shown as
Fig.2.14.1, the entire device cannot be operated, except receiving telegram from the bus.
When downloading application, the entire will be in locking status, and it is unlocked after finish download.
User can lock or unlock each function page individually through the bus. After locking, interface shown as
Fig.2.14.2, this interface cannot be operated except receiving telegram from the bus. If the function page is linked
to home page, the top left corner of corresponding icon on home page will be displayed a locking icon, as shown
as Fig.2.14.3. Function page locking only locks each function page, and has no effect on switching between home
46
K-BUS® KNX/EIB KNX Smart Touch V50s
2.15.Other Functions
Alarm function is activated by the receiving telegram from the bus, pup up the window shown as Fig.2.15.1
when activated, and with the alarm sound. Indicate text, the alarm tone time period and the automatically repeate
When the KNX bus connection of the device is abnormal, the “KNX Connect Failure” at the top of the
interface shown as Fig.2.15.2 above, there is no prompt when the connection is normal.
When the application download of the device is completed or the device power recover, the device will
initialize and load the parameter configuration of ETS, the interface as shown in Fig.2.15.3 above.
When the device is not configured with the home page function or when the home page function is
configured as an invalid page or as functional icon, the home page interface is shown in Fig.2.15.4 above.
47
K-BUS® KNX/EIB KNX Smart Touch V50s
48
K-BUS® KNX/EIB KNX Smart Touch V50s
Screen background can be configured as the default background of the system through Setting page, or insert
(1) Configuring background through the setting page, there are 6 options according to the different themes:
when dark theme is shown in Fig.3.1~Fig.3.3, and light theme is shown in Fig.3.4~3.6. Only select the themes, it
Note: non-pure colour backgrounds are only applied to home page, and the function page is used pure
backgrounds to display.
(2) Inserting new background through Micro SD card, specific steps are as follows:
Note: ①Only support SDHC card and the format should be FAT32 (if the format is not FAT32, it need to be
formatted as FAT32); ②Only support Micro SD cards with capacity not greater than 32GB.
1.Micro SD card setting: placing the pictures in the root directory of the Micro SD card, the resolution of
vertical screen must be 480 * 854 and the horizontal must be 854 * 480. Naming rule as follow:
Note:Supporting pictures with the suffix: jpg, png (Among them, the background colour of the “png” picture must
be opaque.)
2.Insert Micro SD card into the device, if Micro SD card meet the above settings, and valid pictures are
detected, then will pop up a request window to confirm update, as shown in Fig.3.7;
3.Click “Confirm” to update picture; after upgrade, there will pop up a window of the result, if upgrade is
successful, then reboot the device manually to apply the new background to the system; if upgrade is failed, click
any area outside the window to return to the page, as shown in Fig.3.8, Fig.3.9, Fig.3.10 and Fig.3.11.
Note: when upgrading, if the single picture is larger than the remaining storage space of the device (the
total size of the device picture storage disc is about 15 MB), the remaining valid pictures shall be stopped
49
K-BUS® KNX/EIB KNX Smart Touch V50s
Replacing Replacing
ETS options Icon ETS options Icon
ID NO. ID NO.
16 Chandelier 28 Welcome
19 Blind(open/close) 31 Party
20 Blind(up/down) 32 Conference
50
K-BUS® KNX/EIB KNX Smart Touch V50s
Replacing Replacing
ETS options Icon ETS options Icon
ID NO. ID NO.
34 Reading 48 Timer
35 Media 49 Projector
36 Cleaning 50 Multimedia
37 TV 51 Electronic heating
41 Fan 55 General
45 Window 1 59 Lock
46 Window 2 60 Charge
47 Alarm 61 Mute
51
K-BUS® KNX/EIB KNX Smart Touch V50s
Replacing Replacing
ETS options Icon ETS options Icon
ID NO. ID NO.
62 Day/Night 67 Romantic
63 Auto/Manual 68 Doorbell
65 Economy 70 MUR
66 Wake up
52
K-BUS® KNX/EIB KNX Smart Touch V50s
icon_0_a.png icon_0_b.png
icon_0_c.png icon_0_d.png
Insert customized icons to replace the original icons of the system through Micro SD card, specific steps as
follows:
Note: ①Only support SDHC card and the format should be FAT32 (if the format is not FAT32, it need to be
formatted as FAT32); ②Only support Micro SD cards with capacity not greater than 32GB.
1. Micro SD card setting: create a new folder named “Functionicon” under the root directory of Micro SD
card, place icon files to be replaced and name them, specific naming rule refers to the note; the resolution should
53
K-BUS® KNX/EIB KNX Smart Touch V50s
Note: naming rule of the icon files in the Micro SD card as follows:
According to the naming rule in the figure above, for examples, icon in the Fig.4.8 is the default icon of
which replacing ID number is 0, “icon_0_a.png”, “icon_0_b.png” are off status icons; “icon_0_c.png” and
2. Insert Micro SD card into the device, if Micro SD card meet the above settings, and there are valid
Note: ① Replacing pictures according to the icon number of the new picture corresponding to the replacing
ID number: for example, placing “icon_0_a.png”, “icon_0_b.png”, “icon_0_b.png” and “icon_0_d.png” in the
folder named “Functionicon”, it will replace the original icon with ID NO.0; if there is no “icon_0_a.png”, which
is necessary, then will not replace the icon with ID NO.0. If there are only “icon_0_a.png” and “icon_0_b.png” or
only “icon_0_a.png” in the folder, the default icon will be supplemented with “icon_0_a.png”. The rest
② Update pictures: when there is a folder named “Functionicon” in the Micro SD card, and there is a picture
in accordance with valid name and format, then it will update and store (even if the picture is the same as the last
saved).
3. Click “Confirm” to update picture; after upgrade, there will pop up a window of the result, if upgrade is
successful, then reboot the device manually to apply the new function icons to the system; if upgrade is failed,
click any area outside the window to return to the page, as shown in Fig.4.2, Fig.4.3, Fig.4.4 and Fig.4.5.
4. Delete the customized function page icons that has already inserted through Micro SD card, specific
When there is a folder named “Functionicon” in the Micro SD card but no picture in accordance with valid
name and format, there will pop up a window “System resource recovery?”, as shown in Fig.4.6, click “Confirm”,
54
K-BUS® KNX/EIB KNX Smart Touch V50s
then will delete the customized icons that has already inserted and pop up a window “ Success! please reboot...”,
as shown in Fig.4.7, then you need to reboot the device manually to recover the original function icons of the
system.
Note: when upgrading, if the single picture is larger than the remaining storage space of the device (the total
size of the device picture storage disc is about 15 MB), the remaining valid pictures shall be stopped updating,
55
K-BUS® KNX/EIB KNX Smart Touch V50s
Replacing Replacing
ETS options Icon ETS options Icon
ID NO. ID NO.
Heating/Cooling
99 Floor heating 1 111
system
56
K-BUS® KNX/EIB KNX Smart Touch V50s
Replacing Replacing
ETS options Icon ETS options Icon
ID NO. ID NO.
124 Office
57
K-BUS® KNX/EIB KNX Smart Touch V50s
icon_70_a.png icon_70_b.png
Insert customized icon to replace the original icons of the system through Micro SD card, specific steps as
follows:
Note: ①Only support SDHC card and the format should be FAT32 (if the format is not FAT32, it need to be
formatted as FAT32); ②Only support Micro SD cards with capacity not greater than 32GB.
1. Micro SD card setting: create a new folder named “Pageicon” under the root directory of Micro SD card ,
place icon files to be replaced and name them, specific naming rule refers to the note; the resolution should be
Note: naming rule of the icon files in the Micro SD card as follows:
58
K-BUS® KNX/EIB KNX Smart Touch V50s
According to the naming rule in the figure above, for examples, icon in the Fig.5.8 is the default icon with
2. Insert Micro SD card into the device, if Micro SD card meet the above settings, and there are valid
Note: ① Replacing icons according to the icon number of the new picture corresponding to the replacing ID
number: for example, placing “icon_70_a.png” and “icon_70_b.png” in the folder named “Pageicon”, it will
replace the original icon with ID NO.70; If there is only “icon_70_a.png” in the folder, the icons for on status and
off status are the same. The rest customized icon IDs are the same principle.
② Update pictures: when there is a folder named “Pageicon” in the Micro SD card, and there is a picture in
accordance with valid name and format, then it will update and store (even if the picture is the same as the last
saved).
3. Click “Confirm” to update picture; after upgrade, there will pop up a window of the result, if upgrade is
successful, reboot the device manually to apply the new page icons to the system; if upgrade is failed, click any
area outside the window to return to the page, as shown in Fig.5.2, Fig.5.3, Fig.5.4 and Fig.5.5.
4. Delete the customized homepage icons that has already inserted through Micro SD card, specific steps are
as follow:
When there is a folder named “Pageicon” in the Micro SD card but no picture in accordance with valid name
and format, there will pop up a window “System resource recovery?”, as shown in Fig.5.6, click “Confirm”, then
will delete the customized icons that has already inserted and pop up a window “ Success! please reboot...”, as
shown in Fig.5.7, reboot the device manually, after reboot, it will recover the original icons of the system.
Note: when upgrading, if the single picture is larger than the remaining storage space of the device (the total
size of the device picture storage disc is about 15 MB), the remaining valid pictures shall be stopped updating,
59
K-BUS® KNX/EIB KNX Smart Touch V50s
The chapter is mainly used to explain the attention of KNX Smart Touch V50s update firmware process, in
order to use corresponding software correctly and avoid the exception, please be sure to understand the relevant
attention details before operating, if you have any question, you can contact our related sales personnel to
communicate.
status. So must to ensure that the device is running in normal power, then inset the SD card, you can operate to
upgrade.
Put the upgrade package .fwp file of corresponding version in the root directory of the MicroSD card, then
insert the MicroSD card into the device, a pop-up window will appear as shown as Fig.6.1, click “Confirm” to
start upgrading the firmware and enter the upgrade process interface as shown as Fig.6.2, click “Cancel” to exit
the window. When the upgrade complete, the device will note the upgrade success as shown as Fig.6.3 and then
If upgrade failure, device interface as shown as Fig.6.4, please remove the SD card then insert again, click
60
K-BUS® KNX/EIB KNX Smart Touch V50s
2. Note:
①Only support to upgrade via MicroSD card with software package, not support with bus.
②Only support SDHC card and the format should be FAT32 (if the format is not FAT32, it need to be
③During updating process, the power cannot be cut off, the power failure may cause missing UI source files.
If the device is voltage failure, restart the device then the it will note upgrade failure, as shown as Fig.6.4, please
remove the SD card then insert again, click “Reupgrade” to continue upgrading.
④After the upgrade finished, it will display the corresponding UI interface, please refer to the above UI
⑤After the upgrade finished, you can refer to product manual to understand more use details.
61