Contents
1. Scope........................................................................................................ 3
0531
2
HC4601 Service & Identity
1 Scope
This document covers a description of how to generate upload files of configuration data and
other settings using the 150W MF/HF Radio MMI simulator, for the subsequent upload to an
actual radio.
The MMI simulator is a Windows-based program which closely matches both the software
behavior and the display response of the actual radio equipment.
The MMI simulator requires Windows 3.1 or later and the monitor/display must provide a
resolution of 800x600 as a minimum and a 16 bits color depth or better.
The Control Unit (CU) HC4601 Class E has been designed for preprogrammed TX frequen-
cies only. The Sailor distributor is responsible for the task of programming the relevant
frequencies in the actul radio, using this simulator for preparing the upload file containing
these frequencies.
2.2 Run
To run the MMI simulator double click on the program file. This will open the main window.
Next time the program is started, it will open in the same status in which it was closed down.
The following sub-paragraphs describe the menu system in brief.
0531
3
HC4601 Service & Identity
2.2.1 File
This menu covers the handling of upload files and provides an Exit of the MMI Simulator
programme. Upload files are files which may be transferred to the radio, such as e.g.
scanning tables.
2.2.2 System
The System menu covers functions involving the entire system including control of external
equipment connected to radio.
2.2.3 CU
The CU-menu covers Control Unit related functions. Selection of live windows to what
happens within the software.
2.2.4 TU
The TU-menu covers Transceiver Unit related functions.
2.2.5 Log
Enabling/Disabling of logging function and control of which parameters are logged while the
simulator is running.
2.2.6 Test
This function is disabled in this version of the simulator.
2.2.7 Design
This function is disabled in this version of the simulator.
2.2.8 Window
The Window-menu provides the selection of different main window sizes.
2.2.9 Help
The MMI simulator does not provide a genuine help file. This menu item simply contains the
‘About’ box with version information and a list of PC keyboard shortcuts substituting the CU
keypad.
2.3 File
2.3.1 Load
Commands the upload of the created files to the actual radio CU HC4601
2.3.2 Save
Having selected the required settings valid for the actual radio using this MMI simulator it’s
possible to save different parts of these settings in files which may later be uploaded to the
actual radio - or loaded back into the MMI simulator, if so required.
2.3.3 Exit
Exits the MMI simulator programme.
2.4 Save
Use the menu entry File ,then Save , and then one of the following entries
0531
4
HC4601 Service & Identity
2.4.2 Configuration
This function is disabled in the MMI simulator.
2.4.6 Mixture
Selecting this menu item will open a dialog box which allows the selection of any combina-
tion of the above items. Press the associated buttons to select and disable items. Items with
a blue coloured button will be saved. When pressing OK a file name will be prompted for.
The default file name extension is .OXF.
0531
5
HC4601 Service & Identity
Soft keys
Press simultaneously
0531
6
HC4601 Service & Identity
To delete a channel select the same channel number again. The DELETE softkey isvailable.
Select DELETE and confirm by pressing OK in the warning display that follows.
0531
7
HC4601 Service & Identity
Select the menu File followed by Load and then select the file using the standard Windows
file selection method. Drag-n-drop method may also be used.
After modifying the channels setup as required save the file using a new file name.
4.1.1 Setup
In order to perform a software update, a PC with a communication program (e.g. Procomm
Plus or HyperTerminal) and a communication cable are required.
If the Hyper Terminal program is used it is recommended to close and re-start the program if
more than one file has to be downloaded. This should be done between each file download.
4.1.2 PC
In the specific communication program, the Com port must be set to
Item Value
Baudrate 38400
Parity None
Data bits 8
Stop bits 1
4.1.3 Cable
The cable must be a 3-wire cable. Supplying more than 3-wire may damage the PC. The PC
side of the cable must be a 9-pin (or 25-pin) female D-sub connector; the CU/TU side must
be a 9-pin male D-sub connector. The cable may be supplied as accessory.
Designation PC CU TU Designation
‘Com port’ ‘Aux’ ‘Sys’
9-pin 25-pin 9-pin 9-pin
Received Data 2 3 CABLE 2 2 Data Out
Transmitted Data 3 2 3 3 Data In
Ground 5 7 5 5 Ground
0531
8
HC4601 Service & Identity
4.1.4 Procedure
The PC with the communication program and cabling must be ready before the CU/TU is
switched on. The procedure is as follows.
• Download software from the web site or receive it from your distributor if necessary.
• Switch off PC and CU/TU
• Connect cable to unit to be updated
• Switch on PC
• Enter the communcation program. Setup the Com port and select X-Modem protocol.
Select the upload file (the new software version) and begin uploading.
• Switch on the CU/TU.
Upload will now begin. The result of the upload will be written on the PC when the upload is
finished. If the upload was successful the CU/TU reboots automatically.
Use the following menu activations to select between the language files stored in the
HC4500B / HC4500E / HC4601:
FUNC
SETTINGS
OPTIONS
1234 (Password)
ENTER
DSC
LANGUAGE
“Language option”
OK
0531
9
HC4601 Service & Identity
10
HC4601 Service & Identity
11
Thrane & Thrane A/S • [email protected] • www.thrane.com