Catálogo - Solo

This document provides specifications for a C-arm mobile stand used in fluoroscopy and radiography. Key features include a motorized vertical travel of 42 cm, horizontal travel of 22 cm, and orbital rotation from -90 to +45 degrees. The C-arm can generate X-rays between 40-110 kV with mA ranging from 0.2-20 depending on the mode. Additional features include a 23 cm image intensifier, touchscreen user interface, and options for digital imaging processing, archiving, and safety features.

Uploaded by

Pereira Santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views7 pages

Catálogo - Solo

This document provides specifications for a C-arm mobile stand used in fluoroscopy and radiography. Key features include a motorized vertical travel of 42 cm, horizontal travel of 22 cm, and orbital rotation from -90 to +45 degrees. The C-arm can generate X-rays between 40-110 kV with mA ranging from 0.2-20 depending on the mode. Additional features include a 23 cm image intensifier, touchscreen user interface, and options for digital imaging processing, archiving, and safety features.

Uploaded by

Pereira Santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

C-ARM MOBILE STAND

Dimensions and Mechanics Operating Values


• Motor-driven vertical travel: 42 cm • Continuous fluoroscopy:
• Horizontal travel: 22 cm - kV range: 40-110 kV
• Orbital rotation: -90° / +45° - mA range: 0.2-10 mA (200-240 V)
• Angulation: ± 225° • Pulsed fluoroscopy:
• Swiveling (panning): ± 10° - kV range: 40-110 kV
• Source-image receptor distance: 95 cm - mA range: 0.2-16 mA (200-240 V)
• C-arm vertical free space: 76 cm - pulse width: 10-30 ms (200-240 V)
(without skin cone or laser positioning - pulse rate:
device integrated in generator) 1, 2, 4, 8, 12.5, 25 pulses/s (50 Hz)
• C-arm depth: 68 cm 1, 2, 5, 10, 15, 30 pulses/s (60 Hz)
• Width: 80 cm • Digital radiography (snapshot):
• Length: 173 cm / 195 cm - kV range: 40-110 kV
• Height: 175 cm / 217 cm - mA: up to 20 mA
• Weight C-arm mobile stand (weight can vary • Radiography (option):
depending on balancing and configuration): - kV range: 40 -110 kV
343 kg ± 4 %
- mA: up to 10 mA
• Handrail on the I.I.
Output
Brakes
• Pulsed fluoroscopy: 1,650 W
• Steering & braking lever, with parallel
movement of the mobile stand in all directions • Digital radiography (snapshot): 1,980 W

• Color-coded brake handles for all movements


Image Intensifier
X-Ray Generator • Type: cesium iodide

• X-ray tube: stationary anode • DQE (IEC): 65 %

• Single focus: 0.6 (IEC 60336) • Conversion factor: 285 Cd m-2/mR s-1 *

• Max. anode heat content: 85 kHU / 60 kJ • Anti-scatter grid: Pb 8/40 f0 90

• Max. anode heat dissipation: 600 W / 51 kHU/min • Grayscale: 4,096 shades of gray (12 bit)

• Powered by integrated advanced heat • Removable grid (option)


management system 23 cm Image Intensifier
• 1.14 million HU system heat capacity • Central resolution 23-15-10 cm:
• Generator type: 52-58-68 lp/cm

- monoblock • Contrast ratio: 30:1

- high-frequency generator
- frequency: 40 kHz Digital Video Chain
- microprocessor-controlled
Digital Video Camera
• Nominal output (100 kV): 2,0 kW (high contrast, non-interlaced)
• Maximum output: 2,02 kW • Active pixels: 1,048,576

Filtration • Camera matrix: 1,024 x 1,024 pixels

• Total filtration: ≥ 3.9 mm Al + 0.1 mm Cu • Bandwidth of video signal: 20 MHz


• Bandwidth of video amplifier: 50 MHz
Collimator System
• Video (monitor): 1,125 lines
• Collimator rotation: ± 90°
• Signal-to-noise ratio: 68 dB
• Iris collimator: 50-230 mm diameter
• Control: ADR / AVR
• Slot collimator: 50-230 mm diameter
• Virtual collimation without radiation
User Interface Digital Image Processing
Solo Center - TFT Touchscreen Real-Time Processing Functions
on Monitor Support Arm • Recursive filter: 4 levels (out of 16)
• Intuitive icons for ease of use • Stack filter (‘Last Image Hold’): 5 levels
• Resolution: 640 x 480 pixels • Edge enhancement filter: 5 levels
• Multi-lingual user interface • Windowing and step windowing
• Ziehm SmartEye live fluoro screen with • Digital image rotation and reversal
SmartControl without radiation
• Emergency stop button • Grayscale inversion
• X-ray button • Digital collimators
• X-ray indication lamp Application-Oriented Anatomical Programs
• SmartArchive • Bone
Remote Solo Center – Synchronized Touchscreen • Heart, Abdomen, Soft
for Table Side Control (option) • Long Procedure Spine
• Emergency stop button • Urology (option)
• X-ray button
Additional Functions
• X-ray indication lamp
• Metal
• Reposition
Monitors • Pediatric
• High-brightness FullHD 27” split monitor:
Object Detected Dose Control (ODDC)
- screen size: 27” (69 cm)
• Object detection
- native resolution: 1,920 x 1,080 pixels
• Motion detection
- viewing angle (horizontal and vertical): 178°
• Automatic dose reduction
(with contrast ratio ≥ 10:1)
• Automatic metal correction
- tilt range: ± 10°
- contrast ratio : typ. 1,000:1 Image Acquisition

- brightness (panel): ≥ 725 cd/m² • Autosave

- brightness (calibrated): ≥ 550 cd/m2 • Cine loop with auto-playback (option):

- dimensions: 65 cm x 39 cm x 6 cm - sequential image storage and display:


1, 2, 4, 8 frames/s
- mounted on monitor support arm
- start, stop and replay rate controls

• High-brightness and high-contrast Postprocessing Functions


19” DUO monitor (option): • Edge enhancement: 5 levels
- screen size: 2 x 19” (48 cm) • Zoom: 3 levels
- native resolution: 1,280 x 1,024 pixels • Image rotation
- viewing angle (horizontal and vertical): 178° • Windowing and step windowing
(with contrast ratio:10:1) • Grayscale inversion
- tilt range: ± 10° • Image cropping (digital collimators)
- contrast ratio: typ. 1,000:1 • Digital measurement functions: distance/angle (option)
- brightness (panel): typ. 1,000 cd/m² Vascular Package (Option)
- brightness (calibrated): ≥ 550 cd/m² • DSA real-time subtraction with re-masking capability
- dimensions: 68 cm x 45 cm x 9 cm • Pixel shift / landmarking
- mounted on monitor support arm
Anatomical Marking Tool - AMT (Option)
• Mark anatomical structures
• Indicate side of body

Digital Memory
• Storage capacity: 100,000 images
• Image storage: up to 16 bit
• Digital image processing: up to 32 bit
Data Organization Safety Features
• Patient-based data management with 16-image
• Electrical Protection Class I equipment, Type B
mosaic display
(IEC 60601-1)
• Pre-registration via DICOM Worklist (option)
• Security key switch (X-ray)
• Manual input or emergency registration
• Emergency stop button on the C-arm
• Calculated Dose Area Product (DAP)
• DAP value tagged to stored image
• Air Kerma dose display
Options
• Laser positioning device integrated
• Air Kerma value tagged to stored image
in I.I. and/or generator housing
• HIPAA security package (option)
• Skin Cone for the generator: A removable mechanical
• Radiation Dose Structured Report (RDSR) extension of the generator cap in order to avoid a focal
spot to skin distance smaller than 30 cm.
Video Output
• Measured dose area product (DAP) with digital display
• Full HD SDI (split display), 1,920 x 1,080 pixels, 60Hz
• Video connectors for external monitors:
- DVI
Archiving - analog
• Printer (option): paper • Connector for external radiation lamp
• USB port: • Additional handrails on the C for orbital rotation support
- storage capacity depends on storage medium • Remote Solo Center TFT touchscreen
- formats: DICOM, TIFF, Multimedia (AVI) • Wireless Video Package: wireless transmission of the
- downsized formats: DICOM, JPG left/right image from the C-arm to external monitors
• DVD-RW drive (option): • Wireless multifunctional footswitch with programmable
- 4.7 GB storage capacity configuration

- formats: DICOM, TIFF, Multimedia (AVI) - Also available with protection bar

- downsized formats: DICOM, JPG • Power-on key switch

• DICOM viewer software for DVD and USB 3.0


device (option) Accessories
Networking • Disposable sterile covers
• Ziehm NetPort (option): DICOM 3.0 interface • Hand surgery table
(LAN interface or WLAN connection) for digital
• Universal film cassette holder
network integration
• ’Primary Capture‘ mode
• Available DICOM Classes: Regulatory Compliance
- Storage Class incl. multiframe capability and Device Classification
Storage Commitment
• MDD 93/42 EEC, Annex IX: IIb
- Print Class
• U.S. 21CFR: II
- Media Class
Compliance to QM Requirements
- Worklist Class incl. Modality Performed
Procedure Step (MPPS) • EN ISO 13485 certified
- Query Class • MDD 93/42/EEC, Annex II certified
- Retrieve Class • MDSAP certified
- Verification Class - Australian Therapeutic Good Regulation
• WLAN interface for wireless data transfer (option) - Brazil RDC ANVISA n. 16/2013, RDC ANVISA n.
23/2013, RDC ANVISA n. 67/2009
- Canada Medical Device Regulations Part 1 – SOR
Electrical Requirements 98/282
• Power supply: 100-240 VAC (± 10 %), 50/60 Hz - Japan MHLW Ministerial Ordinance 169
• Current consumption: - United States 21 CFR 820
- 10 A continuous (100-120 V) • ISO 14971
- 8 A continuous (200-240 V) • IEC 62304
• Max. impedance: • IEC 62366
- ≤ 0.3 Ω (100-200 V)
Product Compliance
- ≤ 0.6 Ω (220-240 V)
• IEC 60601-1 and relevant collateral
• Installation fuse and particular standards
(release characteristic compliant
• U.S. 21CFR subchapter J
to VDE 0641, Part 11; EN 60898 & IEC 60898):
- 100-200 V: C 20 A or C 32 A
- 220-240 V: C 16 A
ZIEHM VIEWING STATION
(Option)

Dimensions and Mechanics


• Width: 68 cm
• Depth: 64 cm
• Height: 175 cm
• Weight (weight can vary depending on
configuration): 122 kg ± 8 %

Monitors
• High-brightness FullHD 27” split monitor (option):
- screen size: 27” (69 cm)
- native resolution: 1,920 x 1,080 pixels
- viewing angle (horizontal and vertical): 178°
(with contrast ratio > 10:1)
- contrast ratio : typ. 1,000:1
- brightness (panel): ≥ 725 cd/m²
- brightness (calibrated): ≥ 550 cd/m2
- dimensions: 65 cm x 39 cm x 6 cm

• High-brightness and high-contrast


19” DUO monitor (option):
- screen size: 2 x 19” (48 cm)
- native resolution: 1,280 x 1,024 pixels
- viewing angle (horizontal and vertical): 178°
(with contrast ratio:10:1)
- tilt range: ± 10°
- contrast ratio: typ. 1,000:1
- brightness (panel): typ. 1,000 cd/cm²
- brightness (calibrated): ≥ 550 cd/m²
- dimensions: 68 cm x 45 cm x 9 cm

Archiving
• Printer, mounted on viewing station (option):
- paper and film
- paper
© 2020 Ziehm Imaging, 280025 Rev 10 – 07/2020
Ziehm Imaging is constantly improving its products and reserves the right to change the specifications and options without notice.
Presented data are subject to tolerances. Country specific data and options may apply.