Stratix Ethernet Device Specifications: Technical Data
Stratix Ethernet Device Specifications: Technical Data
Original Instructions
Topic Page
Summary of Changes 2
Stratix 2000 Ethernet Unmanaged Switches—Series B 3
Stratix 2000 Ethernet Unmanaged Switches—Series A 9
Stratix 2500 Ethernet Lightly Managed Switches 16
Stratix 4300 Remote Access Routers 20
Stratix 5400 Ethernet Managed Switches 23
Stratix 5410 Ethernet Managed Switches 28
Stratix 5700 Ethernet Managed Switches 34
Stratix 5700 PoE Switches 37
ArmorStratix 5700 Ethernet Managed Switches 43
Stratix 5800 Ethernet Managed Switches and Expansion Modules 48
Stratix 6000 Ethernet Managed Switches 56
Stratix 8000 and 8300 Ethernet Managed Switches 59
Stratix 5100 Wireless Access Point/Workgroup Bridge 65
Stratix 5900 Services Router 66
Stratix 5950 Security Appliance 68
Embedded Switch Technology 72
Configurable NAT Router 75
CIP Security Proxy 78
Accessories 81
Additional Resources 85
Stratix Ethernet Device Specifications Technical Data
Summary of Changes
This publication contains the following new or updated information. This list includes substantive updates only and is not intended to reflect all
changes.
Topic Page
Added CCC, UKCA, and UKEX Certifications 5, 17, 26, 31, 45, 52, 71
The preinstalled fiber SFP modules that are listed in the SFP Ports column use the LC connector type.
76.8 mm
(3.02 in.)
29.6 mm 29.6 mm
68 mm
(1.17 in.) (1.17 in.)
2.68 in.)
2000
R
33.5 mm
25.0 mm
(1.31 in.)
5
6 mm (0.98 in.)
(0.24 in.)
4
3 48.3 mm 35 mm
114.5 mm (1.9 in.) (1.38 in.) 20.0 mm
2
(4.51 in.) (0.79 in.)
1 43.25 mm
(1.70 in.)
OFF
ON
SW1
SW2
32664-M
2000 33.5 mm
R
(1.32 in.) 6 mm
6 8
(0.24 in.) 35 mm
(1.38 in.)
4 6
48.3 mm
114.5mm (1.9 in.) 35 mm 20 mm
3 4
(4.50 in.) (1.38 in.) (0.79 in.)
1 2 43 mm
(1.7 in.)
OFF
ON
SW1
SW2
32663-M
2000
R
52.0 mm
7 8
6 mm
(0.24 in.) (2.05 in.)
5 6
134 mm
3 4
(5.28 in.) 48.3 mm
35 mm
(1.90 in.) 20.0 mm
(1.38 in.)
G1 G2 (0.79 in.)
53.5 mm
1 2
(2.11 in.)
OFF
ON
SW1
SW2
2000
42.5 mm
9 10 17 18
(1.67 in.) 6 mm 70 mm
(0.24 in.) (2.76 in.)
7 8 15 15
134 mm
48.3 mm 35 mm
5 6 13 14
(5.27 in.) 20 mm
(1.90 in.) (1.38 in.) (0.79 in.)
3 4 11 12
1 2 53.5 mm
(2.11 in.)
OFF
ON
SW1
SW2
32661-M
The following table lists Stratix 2000 series A switches and their series B replacements. For specifications of series B switches, see page 3.
Table 5 - Stratix 2000 Series Change
Series A Cat. No. Series B Replacement Cat. No. Change(1)
1783-US4T1F/A 1783-US4T1F/B Same catalog number and configuration
1783-US4T1H/A 1783-US4T1H/B Same catalog number and configuration
1783-US5T/A 1783-US5T/B Same catalog number and configuration
1783-US5TG/A 1783-US5TG/B Same catalog number and configuration
1783-US6T2F/A 1783-US6T2F/B Same catalog number and configuration
1783-US6T2H/A 1783-US6T2H/B Same catalog number and configuration
1783-US7T1F/A 1783-US7T1F/B Same catalog number and configuration
1783-US7T1H/A 1783-US7T1H/B Same catalog number and configuration
1783-US8T/A 1783-US8T/B Same catalog number and configuration
1783-US16T/A 1783-US16T/B Same catalog number and configuration
New catalog number
1783-US14T2S/A 1783-US16T2S/B Replaced 2 GE combo ports with 2 GE copper ports on series B replacement
Added 2 GE SFP slots to series B replacement
New catalog number
1783-US6TG2CG/A 1783-US8TG2GX/B Added 2 FE copper ports to series B replacement
(1) FE = Fast Ethernet; GE = Gigabit Ethernet.
2.5 mm2 (14 AWG) copper wire suitable for 30 °C (86 °F) above
Wire size, ground connection surrounding ambient temperature outside the enclosure, with
a suitable ring terminal
Screw torque, ground terminal, max
Screw torque, power terminals
Wiring category(2)
Enclosure type rating
North American temp code T5
IEC temp code T5
MAC addresses, max supported 8K 8K 1K 8K
Ordered separately:
1783-SFP100FX
SFP modules(3) 1783-SFP100LX No SFP slots No SFP slots No SFP slots
1783-SFP100EXC
1783-SFP100ZXC
(1) See page 83 for recommended products.
(2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(3) For specifications of preinstalled SFP modules, see Table 6. For specifications of SFP modules ordered separately, see Table 64.
6 mm
(0.24 in.)
115 mm
(4.53 in.) 35 mm
(1.38 in.)
6 mm
(0.24 in.)
35 mm
115 mm (1.38 in.)
(4.53 in.)
6 mm
(0.24 in.)
135 mm 35 mm
(5.31 in.) (1.38 in.)
PWR
6 mm
(0.24 in.)
7 8 35 mm
(1.38 in.)
135 mm
(5.31 in.)
5 6
3 4
1783-US8T
1 2
32312-M
6 mm
(0.24 in.)
135 mm
(5.31 in.) 35 mm
(1.38 in.)
38.1 mm
(1.50 in.)
32643-M
45.7 mm
(1.79 in.)
32642-M
To help prevent the switch from overheating, a clearance of 50 mm (1.97 in) minimum on all sides is recommended. Also, verify that aeration holes
are not covered.
73 mm
2.87 in
164 mm
6.46 in
186 mm
146 mm 7.32 in
5.75 in
73 mm
2.87 in
129 mm 13.4 mm
5.08 in 0.53 in 34 mm 15.3 mm
36.4 mm 1.34 in 0.60 in
1.43 in
73 mm
2.87 in
164 mm
6.46 in
186 mm
146 mm 7.32 in
5.75 in
73 mm
2.87 in
129 mm 13.4 mm
46.4 mm
5.08 in 0.53 in
1.84 in
34 mm
15.3 mm
1.34 in
0.60 in
Wire size, DC power connection 0.82…0.52 mm2 (18…20 AWG) solid or stranded copper wire rated at 30 ˚C (86 ˚F), or greater, above the surrounding air temperature
6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.) strip length
Wire size, alarm connection 0.5…0.8 mm2 (20…18 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire,
6.3 mm(0.25 in.) ± 0.5 mm (0.02 in.) strip length
Screw torque,ground terminal 0.51 N•m (4.5 in•lb)
Screw torque, power terminal 0.56 N•m (5.0 in•lb)
Screw torque, alarm terminal 0.23 N•m (2.0 in•lb)
(1) The switch only meets the requirements of IEC 61850-3 when powered by a redundant power supply configuration.
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5400 switches. Actual faceplates vary depending on the catalog number.
1.75 cm
(0.69 in.)
15.54 cm 12.92 cm
(6.12 in.) (5.09 in.)
15.54 cm 16.45 cm
(6.12 in.) (6.48 in.)
13.03 cm
(5.13 in.)
1.24 cm
(0.49 in.)
(1) The switch only meets the requirements of IEC 61850-3 when powered by a redundant power supply configuration.
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 44.45 mm (1.75 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5410 switches. Actual faceplates vary depending on the catalog number.
44.5 cm
(17.75 in.)
1 2 3 4 5 6 7 8 9 10 11 12 25 26 1 4 5 10/100/1000 PoE+ 8 9 12
IN IN
4.45 cm 13 14 15 16 17 18 19 20 21 22 23 24 27 28
Disp.
Mode OUT OUT
(1.75 in.)
TOD
EIP Mod
EIP Net
Setup
GPS
TimeCD
1
2
Out
2
Speed
Duplex
PRP
DLR
PoE
35.6 cm
(14.0 in.)
32564-M
46.53 cm
(18.32 in.)
1 2 3 4 5 6 7 8 9 10 11 12 25 26 1 4 5 10/100/1000 PoE+ 8 9 12
IN IN
3.18 cm 13 14 15 16 17 18 19 20 21 22 23 24 27 28
Disp.
Mode OUT OUT
(1.25 in.)
TOD
EIP Mod
EIP Net
Setup
GPS
TimeCD
1
2
Out
2
Speed
Duplex
PRP
DLR
PoE
.61 cm 32565-M
(.24 in.)
3.28 cm
(1.29 in.)
0.56 cm
(0.22 in.)
3.63 cm
3.63 cm
(1.43 in.)
(1.43 in.)
53.8 cm
(21.18 in.)
46.53 cm
(18.32 in.)
17.66 cm 16.59 cm
(6.95 in.) (6.53 in.)
32564-M
Wire size, DC 0.5…0.8 mm2 (20…18 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max, 6.3 mm (0.25 in.) ±0.5 mm
power connection (0.02 in.) strip length
Wire size, alarm 0.5…0.8 mm2 (20…18 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire, 6.3 mm
connection (0.25 in.) ±0.5 mm (0.02 in.) strip length
Wire size, ground
connection 4.0 mm2 (12 AWG) min, stranded copper wire
Screw torque,
power and alarm 0.23 N•m (2.0 in•lb) 0.23 N•m (2.0 in•lb)
terminals
Screw torque,
ground terminal, 0.96 N•m (8.5 in•lb) 0.4 N•m (3.5 in•lb)
max
Weight, approx 1.11 kg (2.45 lb) 1.25 kg (2.75 lb) 1.38 kg (3.05 lb) 2.04 kg (4.50 lb) 1.22 kg (2.69 lb)
3 - on console and alarm ports 3 - on console ports
Wiring category(2) 2 - on DC power ports 2 - on DC power and alarm ports
2 - on Ethernet ports
Enclosure type None (open-style)
rating
Pilot duty rating Alarm not rated
North American T4
temp code
IEC temp code T4
1783-SFP100FX
1783-SFP100LX
1783-SFP100EXC
1783-SFP100ZXC
1783-SFP100T(4)
SFP modules(3) 1783-SFP1GSX(5)
1783-SFP1GLX(5)
1783-SFP1GEXE(5)
1783-SFP1GZX(5)
1783-SFP1GTE(5)
Memory card 1784-SD1
Substation KEMA (IEEE 1613, IEC 61850 - 3)
Industry standards IEEE 1613 Electric Power Stations Communications Networking
IEC 61850-3 Electric Substations Communications Networking
(1) See page 83 for recommended products.
(2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(3) SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 81.
(4) The 1783-SFP100T module requires Stratix 5700 firmware revision 8.001or later.
(5) Gigabit Ethernet (GE) SFP modules work only in GE SFP slots. For a list of Stratix 5700 catalog numbers with GE SFP slots, see page 34.
Wire size, DC power connection 0.5…0.8 mm2 (20…18 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max,
6.3 mm (0.25 in.) ±0.5 mm (0.02 in.) strip length
Wire size, alarm connection 0.5…0.8 mm2 (20…18 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM)
wire, 6.3 mm (0.25 in.) ±0.5 mm (0.02 in.) strip length
Wire size, ground connection 4.0 mm2 (12 AWG) min, stranded copper wire
Screw torque, power and alarm 0.23 N•m (2.0 in•lb)
terminals
Screw torque, ground terminals, max 0.96 N•m (8.5 in•lb)
Weight, approx 1.11 kg (2.45 lb)
3 - on console and alarm ports
Wiring category(4) 2 - on DC power ports
2 - on Ethernet ports
Pilot duty rating Alarm not rated
Enclosure type rating None (open-style)
North American temp code T4
IEC temp code T4
1783-SFP100FX 1783-SFP1GSX(7)
1783-SFP100LX 1783-SFP1GLX(7)
SFP modules(5) 1783-SFP100EXC 1783-SFP1GEXE(7)
1783-SFP100ZXC
1783-SFP1GZX(7)
1783-SFP100T(6)
1783-SFP1GTE(7)
Memory card 1784-SD1
Substation KEMA (IEEE 1613, IEC 61850 - 3)
Industry standards IEEE 1613 Electric Power Stations Communications Networking
IEC 61850-3 Electric Substations Communications Networking
(1) The initial power allocation and the maximum power allocation on a PoE port are configurable in Device Manager or the Logix Designer application. For details about PoE power budgets, see the
Stratix Managed Switches User Manual, publication 1783-UM007.
(2) For PoE configurations, the power consumption values listed represent the highest values that can be configured using all ports. A general guideline is 0.5 W per 30 W PoE+ port used.
(3) See page 83 for recommended products.
(4) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(5) SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 81.
(6) The 1783-SFP100T module requires Stratix 5700 firmware revision 8.001or later.
(7) Gigabit Ethernet (GE) SFP modules work only in GE SFP slots. For a list of Stratix 5700 catalog numbers with GE SFP slots, see page 34.
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5700 switches. Actual faceplates vary depending on the catalog number.
6 SFP-port Switches 6-port Switches
1783-BMS4S2SGL, 1783-BMS4S2SGA 1783-BMS06SL, 1783-BMS06SA, 1783-BMS06TL, 1783-BMS06TA,
1783-BMS06SGL, 1783-BMS06SGA, 1783-BMS06TGL, 1783-BMS06TGA
8.00 cm 7.48 cm
(3.15 in.) (2.94 in.)
R
Express
Setup
Pwr A
Console
DC+
DC-
12.95 cm 12.95 cm
Pwr B
Com
IN2
Ref
IN1
12.19 cm
(4.8 in.)
11.67 cm
0.75 cm (4.59 in.)
11.45 cm
(0.29 in.) 0.75 cm
(4.51 in.) 10.92 cm
(0.29 in.)
(4.3 in.)
9.14 cm 9.14 cm
(3.6 in.) (3.6 in.)
R R
12.95 cm 12.95 cm
(5.1 in.) (5.1 in.)
11.67 cm
13.58 cm
(4.59 in.)
(5.345 in.)
0.75 cm 0.75 cm
10.92 cm 12.83 cm
(0.29 in.) (0.29 in.)
(4.3 in.) (5.05 in.)
12.70 cm
(5.0 in.)
12.95 cm
(5.1 in.)
13.58 cm
(5.345 in.)
0.75 cm
12.83 cm
(0.29 in.)
(5.05 in.)
±1 kV line-line (DM) and ±2 kV line-earth (CM) on DC ±1 kV line-line (DM) and ±2 kV line-earth (CM) on
power ports DC power ports
Surge transient immunity
IEC 61000-4-5 ±4 kV line-earth (CM) on Ethernet ports ±4 kV line-earth (CM) on Ethernet ports
±1 kV line-line (DM) and ±2 kV line-earth (CM) on alarm
ports
Conducted RF immunity 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
IEC 61000-4-6
Magnetic field immunity 300 A/m long duration and 1000 A/m short duration at 50 Hz and 60 Hz
IEC 6100-4-8
Magnetic pulse immunity 300 A/m pulse
IEC 6100-4-9
±1 kV line-line (DM) and ±2.5 kV line-earth (CM) ±1 kV line-line (DM) and ±2.5 kV line-earth (CM) on
Damped oscillatory wave immunity on DC power ports DC power and alarm ports
IEC 61000-4-18 ±2.5 kV line-earth (CM) on Ethernet ports ±2.5 kV line-earth (CM) on Ethernet ports
Environmental rating IP66, IP67
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the ArmorStratix 5700 switches. Actual faceplates vary depending on the catalog number.
23.75 cm 30.09 cm
(9.35 in.) (11.85in.)
5.78 cm 5.78 cm
(2.2 in.) (2.2 in.)
24.38 cm 24.38 cm 2
14.47 cm (9.6 in.) 14.47 cm 4
(9.6 in.)
(5.6 in.) (5.6 in.)
3.93 cm
3.93 cm
(1.5 in.)
(1.5 in.) 32493
32492
21.58 cm 27.98 cm
(8.4 in.) (11.0 in.)
24-port Switch
1783-ZMS24TA
37.46 cm
(14.75in.)
5.78 cm
(2.2 in.)
24.38 cm
(9.6 in.)
14.47 cm
(5.6 in.)
3.93 cm
(1.5 in.)
32494
35.38 cm
(13.9 in.)
24.84 cm 24.84 cm
(9.77 in.) (9.77 in.)
32496
Wire size, alarm 0.5… 0.8 mm2 (20...18 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire, such as Belden
connections, max part number 9318), 6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.) strip length
Screw torque, 0.565 N•m (5.0 in•lb)
power terminals
Screw torque, power
terminal captive 0.226 N•m (2.0 in•lb)
screw
Screw torque, 0.51 N•m (4.5 in•lb) max
ground connection
Screw torque, 0.23 N•m (2.0 in•lb) max
alarm connection
3 - on console and alarm ports
Wiring category 2 - on DC power ports
2 - on Ethernet ports
Pilot duty rating Alarm not rated
Enclosure type rating None (open-style)
North America T4
temp code
ATEX temp code T4
Memory card 1784-SDHC8
1783-SFP100FX
1783-SFP100LX
1783-SFP100EXC
1783-SFP100ZXC
SFP modules(1) 1783-SFP1GSX
1783-SFP1GLX
1783-SFP1GEXE
1783-SFP1GZX
1783-SFP1GTE
(1) SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 81.
(1) The switch only meets the requirements of IEC 61850-3 when powered by a redundant power supply configuration.
To prevent the switch from overheating, observe the following minimum clearances:
• Top and bottom: 50.8 mm (2.0 in.)
• Sides: 50.8 mm (2.0 in.)
• Front: 50.8 mm (2.0 in.)
These diagrams are representative of the Stratix 5800 switches. Actual faceplates vary depending on the catalog number.
9.14 cm
(3.60 in.) 11.17cm
(4.40 in.)
5800
5800
Console
PoE
Console
Console
1 2 6
PoE
15.24 cm
15.24 cm
Pwr
(6.0 in.)
Setup
7 Mod Net
Express
Setup 2
IN 1 IN 2 OUT
Alarm IN 1 IN 2 OUT
8 Alarm
PoE
10
1783-MMS10E
0.83 cm 0.83 cm
(0.33 in.) (0.33 in.)
8-port Expansion Modules 16-port Expansion Modules All Switches and Expansion Modules
1783-MMX8T, 1783-MMX8E, 1783-MMX16T, 1783-MMX16E, 1783-MMX14T2S
1783-MMX8EA, 1783-MMX8S,
1783-MMX8SA, 1783-MMX6T2S
13.46 cm
7.72 cm (5.30 in.)
6.60 cm (3.40 in.)
(2.60 in.)
6.60 cm
4.06cm (2.60 in.)
(1.60 in.)
5800
5800
9
1
10
2
PoE
3 11
4 12
15.24 cm 15.24 cm
(6.0 in.) 13 (6.0 in.)
5
14
6
PoE
7
15.16 cm
15
(5.97 in.) 32797-M
16
1783-MMX8E
1783-MMX14T2S
32800-M
32799-M
Base Switches without Advanced Feature Support Base Switches without Advanced Feature Support
Mated with Any 8-port Expansion Module Mated with Any 16-port Expansion Module
1783-MMS10B, 1783-MMS10BE, 1783-MMS10, 1783-MMS10B, 1783-MMS10BE, 1783-MMS10,
1783-MMS10E, 1783-MMS10R, 1783-MMS10ER 1783-MMS10E, 1783-MMS10R, 1783-MMS10ER
14.22 cm
(5.60 in.) 16.76 cm
(6.60 in.)
Base Switches with Advanced Feature Support Base Switches with Advanced Feature Support
Mated with Any 8-port Expansion Module Mated with Any 16-port Expansion Module
1783-MMS10EA, 1783-MMS10EAR 1783-MMS10EA, 1783-MMS10EAR
16.25 cm 18.79 cm
(6.40 in.) (7.40 in.)
5800 5800
Console
Console
Console
Console
1 1
2
2
IN 1 IN 2 OUT
IN 1 IN 2 OUT Alarm
Alarm
33807-M
33806-M
Wire size, DC power connection 0.33…3.3 mm2 (22…12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation
max
Wire size, ground connection 3.3 mm2 (12 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater
Screw torque, power and ground terminals 1.36 N•m (12 in•lb)
2 - on DC power ports
Wiring category(2) 2 - on communication ports
Enclosure type rating None (open-style)
North American temp code T4
ATEX temp code T4
1783-SFP1GSX
SFP modules(3) 1783-SFP1GLX
(1) See page 83 for recommended products.
(2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(3) SFP modules are supported only on switches with combo ports or SFP slots. For SFP specifications, see page 81.
Mount the switches, as shown, in the vertical position only. We do not recommend horizontal mounting due to thermal considerations. Follow these
guidelines:
• Provide 50 mm (2 in.) of space on all sides for adequate heat dissipation.
• Leave 100 mm (4 in.) for installation and removal if using the fiber-optic port on the bottom of the 1783-EMS08T switch.
52.07 mm
(2.05 in.)
118 mm (4.64 in.)
107 mm (4.21 in.)
12 cm 1
(0.47 in.) 2
88.9 mm
12 mm 27.7 mm SFP Module Installed
(3.50 in.)
(0.47 in.) (1.09 in.)
Table 41 - Technical Specifications - Stratix 8000 and 8300 Fiber Expansion Module
Attribute 1783-MX08F
Ethernet data rate 100 Mbps
Connecting mode Full-duplex
Optical wavelength 1310 nm
Optical cable length, max Graded index multimode fiber; 2000 m
8 dB with 62.5/125 µm multimode cable
Optical link budget 4 dB with 50/125 µm multimode cable
Connector type IEC 61754-20 LC connector
Table 42 - Technical Specifications - Stratix 8000 and 8300 PoE Expansion Modules
Attribute 1783-MX04E 1783-MX04T04E
Expansion module
Expansion module
Description • 4 ports, copper
4 ports, PoE • 4 ports, PoE
Backplane power 3.3V DC, 0.94 A max 3.34V DC, 1.08 A max
48V DC for PoE 48V DC for PoE
PoE power input(1) 54V DC for PoE+ for a combination of PoE and PoE+ 54V DC for PoE+ for a combination of PoE and PoE+
2.5 A max 2.4 A max
3 W @ 24V DC @ 40˚C (104˚F), 7.3 W max 3.5 W @ 24V DC @ 40˚C (104˚F), 7.9 W max
Power consumption(2) PoE power at 44V: 62 W max PoE power at 44V: 62 W max
Power dissipation 7.3 W 7.9 W
60V (continuous), basic insulation type, expansion backplane to network ports, expansion backplane to power ports, and power ports to
network ports
Isolation voltage No isolation between individual network ports
Type tested at 1570V DC for 60 s
RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to
Wire size, Ethernet connection(3) ISO/IEC 24702
2 - on Ethernet ports
Wiring category(4) 2 - on power ports
Enclosure type rating None (open-style)
North American temp code T4
IEC temp code T4
SFP modules —
(1) The initial power allocation and the maximum power allocation on a PoE port are configurable in Device Manager or the Logix Designer application. For details about PoE power budgets, see the
Stratix Managed Switches User Manual, publication 1783-UM007.
(2) For PoE configurations, the power consumption values listed represent the highest values that can be configured using all ports. A general guideline is 0.5 W per 30 W PoE+ port used.
(3) See page 83 for recommended products.
(4) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
Table 43 - Environmental Specifications - Stratix 8000 and 8300 Expansion Modules (Continued)
1783-MX04S,
Attribute 1783-MX08T 1783-MX08F 1783-MX04E, 1783-MX04T04E
1783-MX08S
ESD immunity 8 kV contact discharges 6 kV contact discharges
This illustration shows dimensions for the 1783-MS10T switch and the 1783-MX08T expansion module. Dimensions for the other switches are the
same as the 1783-MS10T switch. Dimensions for the other expansion modules are the same as the 1783-MX08T expansion module.
Airflow around the switch and through the vents is unrestricted. To prevent the switch from overheating, these minimum clearances must be met:
• Top and bottom: 105 mm (4.13 in.)
• Left and right: 90 mm (3.54 in.)
• Front: 65 mm (2.56 in.)
Switch and Expansion Module Switch and Expansion Module (mated)
14.8 cm
(5.83 in.)
9.81 cm
33.27 cm (3.87 in.)
(13.1 in.) 11.1 cm
(4.38 in.)
Switch
(side view)
11.75 cm
Switch and Expansion Modules (mated) (4.63 in.)
31801-M
For panel-mounting, the height of the center of the mounting holes on both the top and bottom latches measures 8.73 mm (0.34 in.) above the top
surface (or below the bottom surface) of the switch.
On the switch base unit, the tab hole center-to-center spacing is 6.83 cm (2.69 in.).
For expansion modules, the tab hole center-to-center spacing is 4.36 cm (1.72 in.).
1783-WAPZK9 For use in Australia, New Zealand and all other Countries that recognize the Radiocommunications (Short
Regulatory Domain Z Range Devices) Standard.
E134
1783-WAPCK9 For use in China and all other Countries that recognize The Bureau of Radio Administration of MIIT (Fixed
CMIIT ID: 2014AJ2894
Regulatory Domain C Radio Devices).
(1) See the Product Certification link at http://www.ab.com for Declarations of Conformity, Certificates, and other certification details.
196 mm
(7.7 in.)
Wire size, alarm connection 0.8…1.0 mm2 (18…16 AWG) solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire
(such as Belden part number 9318), 6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.) strip length
Wire size, DC power connection 0.8…1.0 mm2 (18…16 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max, 6.3 mm (0.25
in.) ± 0.5 mm (0.02 in.) strip length
Insulation stripping length 6.3 mm (0.25 in.) ± 0.5 mm (0.02 in.)
Wire type Copper
Pilot duty rating Alarm: Not rated
3 - on Console ports
Wiring category(1) 2 -on Power and Alarm ports
2 - on Ethernet ports
30 % dip for 10 ms on DC supply ports
Voltage variation 60 % dips for 100 ms and 1 s on DC supply ports
IEC 61000-4-29 100 % dips for 10 ms and 5 s on DC supply ports
Alarm relay 30V DC, 1 A, or 48V DC, 0.5 A
Screw torque, ground terminal 0.4 N•m (3.5 Ib•in)
Screw torque, power terminal 0.56 N•m (5 Ib•in)
Screw torque, alarm terminal 0.56 N•m (5 Ib•in)
North American temp code T4
ATEX temp code T4
1783-SFP100FX
1783-SFP100LX
SFP modules(2) 1783-SFP1GSX
1783-SFP1GLX
Memory card replacement 1784-SD1
(1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
(2) For SFP specifications, see page 81.
129.54 mm
(5.10 in.)
159.26 mm (6.27
in.)
32593-M
Wire size, DC power connection One 0.33…3.3 mm2 (22…12 AWG) or two 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire rated at 75 °C (167 °F) or
greater, 1.2 mm (3/64 in.) insulation max
Screw torque, power terminal 0.6…0.8 N•m (5…7 in•lb)
1 - on power ports
Wiring category(2) 2 - on communication ports
Enclosure type rating None (open-style)
North American temp code T5 T4A T4
IEC temp code T5 T4 T4
(1) See page 83 for recommended products.
(2) Use this conductor category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1.
This illustration shows dimensions for the 1783-ETAP tap. The dimensions for the other catalog numbers are the same.
122.68 mm
(4.83 in.) 131.57 mm
(5.18 in.)
104.9 mm
(4.13 in.)
35.05 mm
(1.38 in.)
When mounting the 1783-NATR device, allow a minimum clearance between the device and adjacent equipment of
2.54 cm (1 in.) on all sides.
122.68 mm
(4.83 in.) 131.57 mm
(5.18 in.)
104.9 mm
(4.13 in.)
35.05 mm
(1.38 in.)
DC power connections One 0.33…3.3 mm2 (22…12 AWG) or two 0.33…1.3 mm2 (22…16 AWG) solid or stranded copper wire(s) rated at 75
°C (167 °F) or greater, 1.2 mm (3/64 in.) insulation max
Torque, power connector 0.6…0.8 N•m (5…7 lb•In)
Isolation voltage
North American temp code T4
ATEX temp code T4
IECEx temp code T4
This illustration shows dimensions for the 1783-CSP CIP Security™ proxy.
When mounting the 1783-CSP CIP Security proxy, leave a minimum clearance between the device and adjacent equipment of
2.54 cm (1 in.) on all sides.
122.68 mm
(4.83 in.)
131.57 mm
(5.18 in.)
104.9 mm
(4.13 in.)
35.05 mm
(1.38 in.)
Accessories
(1) Digital Optical Monitoring (DOM) iis supported on the switches via the command-line interface (CLI).
(2) ITU-T G.652 SMF as specified by the IEEE 802.3z standard.
(3) The 1783-SFP100T module requires Stratix 5400 or 5410 firmware revision 3.001or later, Stratix 5700 firmware revision 8.001or later, or Stratix 8000 firmware revision 12.001 or later.
(4) The 1783-SFP1GEXE module operates on standard single-mode fiber-optic link spans of up to 40 km in length. For back-to-back connectivity, insert a 5-dB inline optical attenuator between the fiber-
optic cable and the receiving port on the SFP module at each end of the link.
(5) When shorter distances of single-mode fiber (SMF) are used, you can avoid overloading the receiver by inserting an inline optical attenuator in the link. If the fiber-optic cable span loss is less than 8
dB, insert a10-dB inline optical attenuator between the fiber-optic cable plant and the receiving port on the SFP module at each end of the link.
Memory Cards
Cat. No. Description Compatibility
Stratix 5700
1784-SD1 1 GB industrial SD card Stratix 5950
1784-SDHC8 8 GB industrial SDHC card Stratix 5800
1783-MCF CompactFlash card (spare) Stratix 8000
1783-RMCF CompactFlash card (spare) Stratix 8300
Ethernet Cables
Cat. No. Category Description
(1)
Industrial Ethernet Patchcords
RJ45 to RJ45
1585J-M8TBJM-2 Male RJ45 to male RJ45, unshielded twisted pair, teal, high-flex TPE, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4TBJM-2 Male RJ45 to male RJ45, unshielded twisted pair, teal, high-flex TPE, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585J-M8UBJM-2 Male RJ45 to male RJ45, foil and braided shield, teal, high-flex PUR, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4UBJM-2 Male RJ45 to male RJ45, foil and braided shield, teal, high-flex PUR, 4-conductor (2-pair), 2 m (6.56 ft) cable
Category 5
1585J-M8PBJM-2 Male RJ45 to male RJ45, unshielded twisted pair, teal, riser PVC, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4PBJM-2 Male RJ45 to male RJ45, unshielded twisted pair, teal, riser PVC, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585J-M8HBJM-2 Male RJ45 to male RJ45, foil shield, teal, 600V PVC, 8-conductor (4-pair), 2 m (6.56 ft) cable
1585J-M4HBJM-2 Male RJ45 to male RJ45, foil shield, teal, 600V PVC, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585J-M8TGJM-2 Category 6 Male RJ45 to male RJ45, foil shield, teal, high-flex TPE, 8-conductor (4-pair), 2 m (6.56 ft) cable
M12 to M12, D-code
1585D-M4TBDM-2 M12 D-code to M12 D-code, unshielded twisted pair, teal, high-flex TPE, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585D-M4UBDM-2 Category 5e M12 D-code to M12 D-code, foil and braided shield, teal, high-flex PUR, 4-conductor (2-pair), 2 m (6.56 ft) cable
1585D-M4PBDM-2 M12 D-code to M12 D-code, foil and braided shield, teal, riser PVC, 4-conductor (2-pair), 2 m (6.56 ft) cable
M12 X-code to M12 X-code
1585D-M8TGDM-2 Category 6 M12 X-code to M12 X-code, foil and braided shield, teal, high-flex TPE, 8-conductor (4-pair), 2 m (6.56 ft) cable
Industrial Ethernet Cable Spools(2)
1585-C8TB-S100 Cable spool, unshielded twisted pair, teal, high-flex TPE, 8-conductor (4-pair), 100 m (328.08 ft)
1585-C8UB-S100 Cable spool, foil and braided shield, teal, high-flex PUR, 8-conductor (4-pair), 100 m (328.08 ft)
Category 5e
1585-C8PB-S100 Cable spool, unshielded twisted pair, teal, riser PVC, 8-conductor (4-pair), 100 m (328.08 ft)
1585-C8HB-S100 Cable spool, foil shield, teal, 600V PVC, 8-conductor (4-pair), 100 m (328.08 ft)
Accessories
1585J-M8CC-H RJ45 IDC connector
1585D-M4DC-H Category 5e M12 D-code IDC connector
1585D-M4DC-SH M12 D-code IDC connector compatible with 600V cable spools
(1) Patchcords are available in lengths of up to 80 m (262.46 ft) in 0.1 m (0.328 ft) increments. Refer to http://www.ab.com/catalogs for full product offering.
(2) Cable spools are available in 100,300 m (328.08 ft) and 600 m (1968.5 ft) lengths.
Additional Resources
These documents contain additional information concerning related products from Rockwell Automation. You can view or download publications at
rok.auto/literature.
Resource Description
Configurable NAT Router User Manual, publication 1783-UM008 Describes how to install, configure, and troubleshoot the NAT router.
Describes how to implement services and data objects on a TCP/UDP/IP based
EtherNet/IP Industrial Protocol White Paper, publication ENET-WP001 Ethernet network.
Describes how to configure and troubleshoot Stratix 5400, 5410, 5700, 8000, 8300, and
Stratix Managed Switches User Manual, publication 1783-UM007 ArmorStratix 5700 switches.
Stratix 2000 Ethernet Unmanaged Switches User Manual, publication 1783-UM011 Describes how to use DIP switches and status indicators on Stratix 2000 switches.
Stratix 2500 Lightly Managed Switches User Manual, publication 1783-UM009 Describes how to configure and troubleshoot Stratix 2500 switches.
Stratix 5800 Ethernet Managed Switches User Manual, publication 1783-UM012 Describes how to configure and troubleshoot Stratix 5800 switches.
Stratix 6000 Ethernet Managed Switches User Manual, publication 1783-UM001 Describes how to configure and troubleshoot Stratix 6000 switches.
Stratix 5100 Wireless Access Point/Workgroup Bridge User Manual, Describes how to install, configure, and troubleshoot the wireless access point.
publication 1783-UM006
Stratix 5900 Services Router User Manual, publication 1783-UM005 Describes how to install, configure, and troubleshoot the router.
Stratix 5950 Security Appliance User Manual, publication 1783-UM010 Describes how to install, configure, and troubleshoot the security appliance.
CIP Security Proxy User Manual, publication 1783-UM013 Describes how to configure an troubleshoot the CIP Security proxy.
Describes how to configure and use EtherNet/IP devices to communicate on the
EtherNet/IP Network Devices User Manual, ENET-UM006 EtherNet/IP network.
Describes basic Ethernet concepts, infrastructure components, and infrastructure
Ethernet Reference Manual, ENET-RM002 features.
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, rok.auto/certifications. Provides declarations of conformity, certificates, and other certification details.
Industrial Components Preventive Maintenance, Enclosures, and Contact Ratings Provides a quick reference tool for Allen-Bradley industrial automation controls and
Specifications, publication IC-TD002 assemblies.
Designed to harmonize with NEMA Standards Publication No. ICS 1.1-1987 and provides
Safety Guidelines for the Application, Installation, and Maintenance of Solid-state Control, general guidelines for the application, installation, and maintenance of solid-state control
publication SGI-1.1 in the form of individual devices or packaged assemblies incorporating solid-state
components.
Documentation Feedback
Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the
form at rok.auto/docfeedback.
Allen-Bradley, ArmorStratix, expanding human possibility, Rockwell Automation, Rockwell Software, and Stratix are trademarks of Rockwell Automation, Inc.
CIP, CIP Security, CIP Sync, and EtherNet/IP is a trademark of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.
Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur