0% found this document useful (0 votes)
77 views28 pages

B industrialSD750

The document describes a brochure for variable speed drives from Power Electronics. It discusses the company's genetics/capabilities including over 60 GW of installed power capacity. It then describes several variable speed drive products from Power Electronics, including the SD750, SD750SP, SD750FR, and SD750K, highlighting common features such as full frontal access, low dV/dt filters, harmonic filters, and an innovative cooling system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views28 pages

B industrialSD750

The document describes a brochure for variable speed drives from Power Electronics. It discusses the company's genetics/capabilities including over 60 GW of installed power capacity. It then describes several variable speed drive products from Power Electronics, including the SD750, SD750SP, SD750FR, and SD750K, highlighting common features such as full frontal access, low dV/dt filters, harmonic filters, and an innovative cooling system.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 28

Brochure

Easy to drive

Variable Speed Drives


POWER ELECTRONICS CONTENTS

PE genetics Page. 4 — 5

Our products Page. 6 — 47

Our secret
Page. 48— 50
POWER ELECTRONICS OUR GENETICS

Energy efficiency We handle everything in-house: from


design and manufacture to testing.
for every situation
+
60

More than
GW
of installed
AC power
Solar + Storage

+
25
of annual
GW

production
capacity

+10k
+
30
years of
of distributed products + 25 excellence
International
+30MW +50
installed in solar pump applications countries delegations
4 5
POWER ELECTRONICS OUR PRODUCTS

“Vertical
integration gives

SD
us flexibility

750
to adapt to
customers’
requirements”

6 7
POWER ELECTRONICS OUR PRODUCTS

SD750
Page. 10 — 23

VARIABLE
SPEED
Page. 24 — 29

SD750SP
Page. 30— 37

SD750FR
DRIVES
SD750K
Page. 38 — 47

8 9
POWER ELECTRONICS COMMON FEATURES OUR PRODUCTS
All our equipment
share the following

SD750
1
caracteristics

The core of the family Full frontal access


Maintenance and cleaning reduce company yield,
therefore SD750 has been designed with the latest
SD750 is the most flexible and extensive series with a compact design engineering good practices to reduce time, spare parts
for easy installation, commissioning and maintenance. cost and to increase availability.

1,5kW - 2200kW 380-690Vac Up to 50ºC

2 Low dV/dt and RFI filter


SD750 includes built-in as standard dV/dt filter that
reduces the dV/dt value to 500-800V/μs depending on
the drive size and rated voltage, minimizing the voltage
peaks at the motor winding. It is the unique drive in
the market focused on the customer´s needs such as

3
wiring and motor cost reduction.

Harmonics filter
High input impedance given by the 3% input chokes
protects the drive against any grid anomaly and
enhances its THDi performance in weak grids.

Higher power density


With an advanced smart design, we have
developed a highpower drive with a
4
smaller compact solution that is able to be
integrated in any application.
Following our reliability philosophy of oversizing critical
components, the SD750 series will provide you a reliable
and powerful compact solution for easy installation,
commissioning and maintenance.

10 11
POWER ELECTRONICS OUR PRODUCTS

Cooling
System
5
Innovative

SD750 truly offers operation up to 50°C due to oversized heat sinks


with a junction temperature below 100°C and no power derating.
Level 3

Level 2

Level 1

Moreover, we adapt our products to worldwide operation under the


most adverse conditions without supervision. We achieve this due
to multiple internal temperature sensors and oversized heatsinks.

LEVEL 1
Electronics
The electronic components are completely isolated
in what is called the “electronics area”. The heat
exchange of the electronic components is separated
from the areas that cool the heat sink and the electric
filtering components, making the cooling of these
components much more efficient.

LEVEL 2
Cooling
SD750 cooling system uses efficient axial fans at low
speed which provide three main benefits:

• The internal dust deposition ratio in polluted


environments (cement, mining, minerals, metal
industry, etc) is significantly decreased at low air
speeds, therefore the maintenance frequency is
reduced.

• The internal air pressure losses are reduced


exponentially, increasing cooling system efficiency.

• The sound levels are reduced in order to favour a


comfortable operation.

LEVEL 3
Input filter
The input filters are enclosed separately, optimizing
their cooling capacity, degree of protection and
increasing their long life operation.

12 13
POWER ELECTRONICS OUR PRODUCTS

6 Connectivity
SD750 is compatible with the most used industrial
protocols in the market. Incorporating Modbus RTU and
Modbus TCP protocols as standard and as an option
Ethernet/IP, Profibus and ProfiNet. Maximum safety
7
With motor relay features built-in as standard the
SD750 hardware offers continuous monitoring of the
motor electric values and its temperature (PTC sensor,
and PT100). As a result, the highly advanced software

8
provides full motor and drive protection.

Advanced
Control and push buttons
Motor
Display Control
Power Electronics’ success is measured by our customer’s
Multiple drives synchronization applications satisfaction. The motor control systems developed by Power
Electronics have been designed to meet the most demanding
features. The SD750 integrates V/f control and two vector
Output filters and equipment controls: Power Motor Control (PMC) and the Advanced Vector
Control (AVC) as standard.

9
Digital inputs

Output relays

Analogue inputs and outputs


Dedicated software
Comparators tools and macros
The lessons learned from many customers and working closely with
them have allowed Power Electronics to design of the most flexible
tools for user customization and process monitoring.

With a wide range of ready-made macros to optimize any application


productivity and usability and being customizable to meet the precise
application needs of every customer. The SD750 series monitors the
real performance information about motor and drive status integrating
an accurate power grid analyzer and drive diagnosis.

14 15
POWER ELECTRONICS OUR PRODUCTS
HARDWARE Digital inputs 6 programmable, Active high (24 Vdc), Isolated power supply
SD750 Digital outputs 3 programmable changeover relays (250 Vac, 8 A or 30 Vdc, 8 A)
3 programmable differential inputs: 0-20 mA, 4-20 mA, 0-10 Vdc and ±10 Vdc. PT100.
Analogue input
1.5kW – 2200kW (Optically isolated).
INPUT Power range [1]
Analogue outputs 2 isolated programmable outputs: 0-20 mA, 4-20 mA, 0-10 Vdc and ±10 Vdc
Voltage range 380 – 480Vac (±10%), 525 – 690Vac (-5/+10%)
Encoder inputs (optional) 1 differential encoders input. Voltages inputs from 5 to 24Vdc
Input frequency 50 Hz / 60 Hz (± 6%) +24 Vdc user power supply (Max. 180 mA) regulated and short-circuit protected
Input rectifier technology Diode-Diode F1-F2/Thyristor-Diode F3-F11 (multipulse available [1]
) User power supply +10 Vdc user power supply (Max. 2 potentiometers R=1 kΩ) regulated and short-circuit
protected
Displacement power factor ≥ 0.98 Digital I/O board:
(DPF = cos Φ )
5 Digital inputs: Programmable inputs and active high (24Vdc). Optically isolated
Power factor (PF= I1 /Irms· cos Φ) ≥ 0.91 5 Digital outputs: programmable multi-function relays
I/O Extension board (optional)
Momentary power loss > 2 seconds (depending on the load inertia) Analogue I/O board:
2 Analogue input: Programmable and differential input
Second environment (Industrial): C3 Standard.
2 Analogue output: Programmable outputs in voltage/current
EMC input filter First environment (Domestic): C2 (Optional), C1 consult with Power Electronics.
IT filter optional External power supply (optional) 24 V External power supply integrated
SD card Port for an external SD Card. Data Logging, events registration
Harmonics filter Choke coils 3% impedance
COMMUNICATION USB port
Current THD (%) < 40%
Standard hardware RS485 port
Regenerative No Ethernet
OUTPUT Output frequency [2] 0... 599 Hz Optical fibre
Optional hardware
Communication boards
Constant torque / heavy duty: 150% during 60 seconds at 50°C
Overload capacity Variable torque / normal duty: 120% during 60 seconds at 40°C Modbus-RTU
Standard protocol
Ethernet (Modbus TCP)
Efficiency (at full load) ≥ 98%
Profibus-DP
V / Hz Optional protocol Ethernet IP
VECTOR CONTROL ProfiNet
Control method Open Loop: PMC speed / torque control, AVC: speed / torque control Type Removable
CONTROL PANEL
Close Loop (Encoder): PMC speed / torque control, AVC: speed / torque control
Length 3 meters (optional)
PMSM I/f &, Sensorless and HEPOL (High Efficiency Performance Open Loop)
Connection USB
Carrier frequency 4 to 8 kHz - PEWave
LED RUN: Motor receiving power supply
500 - 800 V/µs Visualization leds
Output dV/dt filter LED FAULT: Flashing displays that a fault has occurred
Output cable length [4] USC 300 m - SC 150 m LCD screen
LCD display Keypad with 8 keys to control and configure the drive, start and stop/reset
Dynamic brake External B150 Dynamic Brake - (Frames 1 and 2 integrated)
Independent memory
ENVIRONMENTAL Minimum: -20°C Maximum: +50°C (Heavy duty) Average current and 3-phase motor current
Operation ambient temperature Minimum: -20°C Maximum: +40°C (Normal duty)
CONDITIONS Average voltage and 3-phase motor voltage
Storage temperature Minimum: -40°C Maximum: +70°C Display information Average input voltage and 3-phase input voltage
Altitude 1000 m 3-phase input and output frequency
Power altitude derating [1] >1000m, 1% PN (kW) per 100m; 4000m maximum (for higher altitude consult with PE) DC Bus Voltage
Ambient humidity <95%, non-condensing Drive status
Speed, Torque, Power, Power factor of motor
Degree of protection IP20 [5], IP54 [6], IP42 [7], Marine series adapted (IP44/IP54, under request)
Register of total and partial drive running time with reset function. (hours)
Amplitude: ± 1mm ( 2 Hz-13.2 Hz), ± 0.075 mm (13.2 Hz-57 Hz) Register of total and partial drive energy consumption with reset function (kWh)
Vibration Acceleration: 6.86 m/s2 (13.2 Hz-57 Hz), 9.8 m/s2 (57 Hz-150 Hz) Relay status
Heating resistors Optionals Digital inputs / PTC status
PROTECTIONS Rotor locked, Motor overload (thermal model), Output current limit, Phase current imbalance, Output comparator status
Motor protections Others
Phase voltage imbalance, Motor over-temperature (PT100 signal), Speed limit, Torque limit Analogue inputs and sensor values
IGBT’s overload, Input phase loss, Low input voltage, High input voltage, DC Bus voltage Analogue output value
limit, Low DC Bus voltage, IGBT temperature, Heat-sink over-temperature, Power supply Motor overload and equipment status
Drive protections fault, Drive thermal model, Ground fault, Software and Hardware fault, Analogue input Drive and rectifier temperature
signal loss (speed reference loss), Safe stop/Emergency Stop Fault history (last 6 faults)
Real time clock
Perpetual calendar
REGULATIONS Certifications CE, cTick, UL, cUL, Marine certifications (under request)
EMC Directive (2004/108/CE)
Electromagnetic compatibility
IEC/EN 61800-3
LVD Directive (2006/95/CE)
IEC/EN 61800-2 General requirements
Design and construction IEC/EN 61800-5-1 Safety
IEC/EN 60146-1-1 Semiconductor converters
IEC60068-2-6 - Vibration
Functional safety IEC/EN 61800-5-2 Safety Stop (STO)

NOTES [1] Consult availability with Power Electronics. [5] Available for 380–480Vac up to frame 4.
[2] For operation frequencies higher than 100 Hz, consult Power Electronics. [6] Applicable to the electronics.

16 [3] Valid for frames 3 to 11 depending on the SD750 rated power. For frames
1 and 2 it is available optional filter.
[4] SC: Shielded cable, USC: Unshielded Cable. Follow Power Electronics installation
[7] For stand-alone models.
17
recommendations. For greater cable lengths, consult Power Electronics.
POWER ELECTRONICS OUR PRODUCTS

SD750 CONFIGURATION TABLE


A B C D Operation temperature 40°C Operation temperature 50°C
SD750 ND OUTPUT
INPUT DEGREE OF GROUNDING > 4000 METER NORMAL DUTY HEAVY DUTY OVERLOAD
SERIES CURRENT FRAME CODE
VOLTAGE PROTECTION CONNECTION (above sea level) Motor power Motor power I(A) Motor power Motor power I(A) (A)
SD750 (kW) (hp) Rated (kW) (hp) Rated
SD75S 0006 6A 5 380-480 Vac 2 IP20 S TT/TN S Not needed
Standard SD75S0006 5BCD 2.2 3 5 1.5 2 3 6
SD75S0008 5BCD 4 5 7 2.2 3 5 8
... ... 6 525-690 Vac 5 IP54 T IT A Needed SD75S0011 5BCD 5.5 7,5 10 4 5 8 13
1 SD75S0015 5BCD 7.5 10 14 5.5 7,5 11 16
SD75S0024 5BCD 11 15 22 7.5 10 16 25
3100 3100 A 4 IP42
SD75S0030 5BCD 15 20 27 11 15 22 33
SD75S0040 5BCD 18.5 25 36 15 20 29 44
SD75S0048 5BCD 22 30 44 18.5 25 35 52
2 SD75S0060 5BCD 30 40 55 22 30 44 65
SD75S0075 5BCD 37 50 68 30 40 55 82

POWER RANGE AT 440VAC


SD75S0095 5BCD 45 60 86 37 50 68 103
SD75S0110 5BCD 55 75 100 45 60 82 123
3
SD75S0145 5BCD 75 100 132 55 75 105 157
SD75S0180 5BCD 90 125 164 75 100 136 205
SD750 STANDARD RATINGS SD75S0200 5BCD 110 150 182 90 125 155 232
4
SD75S0260 5BCD 132 200 236 110 150 191 286
SD75S0320 5BCD 160 250 291 132 200 227 341
Operation temperature 40°C Operation temperature 50°C 5
SD75S0400 5BCD 220 300 364 160 250 300 450
NORMAL DUTY HEAVY DUTY OVERLOAD
FRAME CODE SD75S0450 5BCD 250 350 409 220 300 336 505
Motor power Motor power I(A) Motor power Motor power I(A) (A)
6 SD75S0570 5BCD 315 400 518 250 350 418 627
(kW) (hp) Rated (kW) (hp) Rated
SD75S0700 5BCD 400 550 636 315 450 527 791
SD75S0006 5BCD 2.2 3 6 1.5 2 3 6
SD75S0800 5BCD 450 650 727 355 500 591 886
SD75S0008 5BCD 4 5 8 2.2 3 6 9
7 SD75S0900 5BCD 500 700 818 400 550 655 982
SD75S0011 5BCD 5.5 7,5 11 4 5 9 14
SD75S1050 5BCD 560 800 955 450 700 764 1145
1 SD75S0015 5BCD 7.5 10 15 5.5 7,5 12 18
SD75S1140 5BCD 630 900 1036 500 750 841 1262
SD75S0024 5BCD 11 15 24 7.5 10 18 27 8
SD75S1400 5BCD 800 1000 1273 630 900 1045 1568
SD75S0030 5BCD 15 20 30 11 15 24 36
SD75S1550 5BCD 900 1250 1409 710 1000 1145 1718
SD75S0040 5BCD 18.5 25 40 15 20 32 48
SD75S1800 5BCD 1000 1400 1636 800 1150 1309 1964
SD75S0048 5BCD 22 30 48 18.5 25 38 57
SD75S1950 5BCD 1100 1500 1773 900 1250 1436 2155
2 SD75S0060 5BCD 30 40 60 22 30 48 72 >8
SD75S2250 5BCD 1200 1750 2045 1000 1450 1636 2455
SD75S0075 5BCD 37 50 75 30 40 60 90
SD75S2750 5BCD 1500 2200 2500 1200 1750 2000 3000
POWER RANGE AT 400VAC

SD75S0095 5BCD 45 60 95 37 50 75 113


SD75S3100 5BCD 1750 2450 2818 1400 2000 2273 3409
SD75S0110 5BCD 55 75 110 45 60 90 135
3
SD75S0145 5BCD 75 100 145 55 75 115 173
SD75S0180 5BCD 90 125 180 75 100 150 225
SD75S0200 5BCD 110 150 200 90 125 170 255
4
SD75S0260 5BCD 132 200 260 110 150 210 315
SD75S0320 5BCD 160 250 320 132 200 250 375
5
SD75S0400 5BCD 220 300 400 160 250 330 495
SD75S0450 5BCD 250 350 450 220 300 370 555
6 SD75S0570 5BCD 315 400 570 250 350 460 690
SD75S0700 5BCD 400 550 700 315 450 580 870
SD75S0800 5BCD 450 650 800 355 500 650 975
7 SD75S0900 5BCD 500 700 900 400 550 720 1080
SD75S1050 5BCD 560 800 1050 450 700 840 1260
SD75S1140 5BCD 630 900 1140 500 750 925 1388
8
SD75S1400 5BCD 800 1000 1400 630 900 1150 1725
SD75S1550 5BCD 900 1250 1550 710 1000 1260 1890
SD75S1800 5BCD 1000 1400 1800 800 1150 1440 2160
SD75S1950 5BCD 1100 1500 1950 900 1250 1580 2370
>8
SD75S2250 5BCD 1200 1750 2250 1000 1450 1800 2700
SD75S2750 5BCD 1500 2200 2750 1200 1750 2200 3300
SD75S3100 5BCD 1750 2450 3100 1400 2000 2500 3750

18 19
POWER ELECTRONICS OUR PRODUCTS

STANDARD RATINGS
Operation temperature 40°C Operation temperature 50°C Operation temperature 40°C Operation temperature 50°C
NORMAL DUTY HEAVY DUTY OVERLOAD NORMAL DUTY HEAVY DUTY OVERLOAD
FRAME CODE FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A) Motor power Motor power I(A) Motor power Motor power I(A) (A)
(kW) (hp) Rated (kW) (hp) Rated (kW) (hp) Rated (kW) (hp) Rated
SD75S0006 5BCD 2.2 3 5 1.5 2 3 6 SD75S0055 6BCD 37 50 55 30 40 42 63
SD75S0008 5BCD 4 5 7 2.2 3 5 8 SD75S0065 6BCD 45 60 65 37 50 52 78
SD75S0011 5BCD 5.5 7,5 9 4 5 8 12 4 [1] SD75S0075 6BCD 55 75 75 45 60 62 93
1 SD75S0015 5BCD 7.5 10 13 5.5 7,5 10 15 SD75S0100 6BCD 75 100 100 55 75 80 120
SD75S0024 5BCD 11 15 20 7.5 10 15 23 SD75S0120 6BCD 90 125 120 75 100 105 157
SD75S0030 5BCD 15 20 25 11 15 20 30 SD75S0160 6BCD 110 150 160 90 125 130 195

POWER RANGE AT 525VAC


SD75S0040 5BCD 18.5 25 33 15 20 27 40 5 SD75S0180 6BCD 132 180 180 110 150 150 225
SD75S0048 5BCD 22 30 40 18.5 25 32 48 SD75S0210 6BCD 150 200 210 132 180 170 255
2 SD75S0060 5BCD 30 40 50 22 30 40 60 SD75S0250 6BCD 185 250 250 150 200 210 315
SD75S0075 5BCD 37 50 63 30 40 50 75 6 SD75S0310 6BCD 220 300 310 185 250 260 390
POWER RANGE AT 480VAC

SD75S0095 5BCD 45 60 79 37 50 63 94 SD75S0400 6BCD 280 400 400 220 300 320 480
SD75S0110 5BCD 55 75 92 45 60 75 113 SD75S0480 6BCD 355 450 480 280 400 385 578
3 7
SD75S0145 5BCD 75 100 121 55 75 96 144 SD75S0570 6BCD 400 550 570 355 450 460 690
SD75S0180 5BCD 90 125 150 75 100 125 188 SD75S0680 6BCD 500 650 680 400 550 550 825
8
SD75S0200 5BCD 110 150 167 90 125 142 213 SD75S0825 6BCD 560 800 825 500 650 660 990
4
SD75S0260 5BCD 132 200 217 110 150 175 263 SD75S0930 6BCD 630 900 930 560 800 750 1125
SD75S0320 5BCD 160 250 267 132 200 208 313 SD75S1050 6BCD 710 1000 1050 630 900 840 1260
5
SD75S0400 5BCD 220 300 333 160 250 275 413 SD75S1200 6BCD 900 1200 1200 710 1000 950 1425
SD75S0450 5BCD 250 350 375 220 300 308 463 SD75S1400 6BCD 1000 1400 1400 900 1200 1140 1710
6 SD75S0570 5BCD 315 400 475 250 350 383 575 >8 SD75S1550 6BCD 1100 1500 1550 1000 1400 1270 1905
SD75S0700 5BCD 400 550 583 315 450 483 725 SD75S1750 6BCD 1250 1700 1750 1100 1500 1420 2130
SD75S0800 5BCD 450 650 667 355 500 542 813 SD75S1850 6BCD 1400 1800 1850 1250 1700 1500 2250
7 SD75S0900 5BCD 500 700 750 400 550 600 900 SD75S2200 6BCD 1600 2100 2200 1400 1800 1800 2700
SD75S1050 5BCD 560 800 875 450 700 700 1050 SD75S2500 6BCD 1800 2400 2500 1600 2100 2000 3000
SD75S1140 5BCD 630 900 950 500 750 771 1157
8
SD75S1400 5BCD 800 1000 1167 630 900 958 1438
Operation temperature 40°C Operation temperature 50°C
SD75S1550 5BCD 900 1250 1292 710 1000 1050 1575
NORMAL DUTY HEAVY DUTY OVERLOAD
SD75S1800 5BCD 1000 1400 1500 800 1150 1200 1800 FRAME CODE
SD75S1950 5BCD 1100 1500 1625 900 1250 1317 1975 Motor power Motor power I(A) Motor power Motor power I(A) (A)
>8 (kW) (hp) Rated (kW) (hp) Rated
SD75S2250 5BCD 1200 1750 1875 1000 1450 1500 2250
SD75S2750 5BCD 1500 2200 2292 1200 1750 1833 2750 SD75S0055 6BCD 45 60 55 37 50 42 63
SD75S3100 5BCD 1750 2450 2583 1400 2000 2083 3125 SD75S0065 6BCD 55 75 65 45 60 52 78
4 [1] SD75S0075 6BCD 60 90 75 55 75 62 93
SD75S0100 6BCD 90 125 100 60 90 80 120
SD75S0120 6BCD 110 150 120 90 125 105 157
SD75S0160 6BCD 132 180 160 110 150 130 195

POWER RANGE AT 600VAC


5 SD75S0180 6BCD 150 200 180 132 180 150 225
SD75S0210 6BCD 180 250 210 150 200 170 255
SD75S0250 6BCD 220 300 250 180 250 210 315
6 SD75S0310 6BCD 250 350 310 220 300 260 390
SD75S0400 6BCD 355 450 400 250 350 320 480
SD75S0480 6BCD 400 550 480 355 450 385 578
7
SD75S0570 6BCD 500 650 570 400 550 460 690
SD75S0680 6BCD 560 800 680 500 650 550 825
8
SD75S0825 6BCD 710 950 825 560 800 660 990
SD75S0930 6BCD 800 1100 930 710 950 750 1125
SD75S1050 6BCD 900 1250 1050 800 1100 840 1260
SD75S1200 6BCD 1000 1400 1200 900 1250 950 1425
SD75S1400 6BCD 1200 1600 1400 1000 1400 1140 1710
>8 SD75S1550 6BCD 1300 1700 1550 1200 1600 1270 1905
SD75S1750 6BCD 1500 2000 1750 1300 1700 1420 2130
SD75S1850 6BCD 1600 2200 1850 1500 2000 1500 2250
SD75S2200 6BCD 1900 2500 2200 1600 2200 1800 2700
SD75S2500 6BCD 2200 2900 2500 1900 2500 2000 3000

20 NOTES [1] Consult availability with Power Electronics.


21
POWER ELECTRONICS OUR PRODUCTS

DIMENSIONS ANS WEIGHTS


Operation temperature 40°C Operation temperature 50°C
NORMAL DUTY HEAVY DUTY OVERLOAD FRAME W D H WEIGHT (kg)
FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A) 1 190 273 507 15
(kW) (hp) Rated (kW) (hp) Rated 2 296 323 510 26
SD75S0055 6BCD 45 60 55 37 50 42 63 3 301 358 854 67.5
SD75S0065 6BCD 55 75 65 45 60 52 78 4 320 466 1249 94
4 [1] SD75S0075 6BCD 75 100 75 55 75 62 93 5 431 529 1716 200
SD75S0100 6BCD 90 125 100 75 100 80 120 6 780 529 1715 335
SD75S0120 6BCD 110 150 120 90 125 105 157 7 1132 529 1715 479
SD75S0160 6BCD 132 200 160 110 150 130 195 8 1482 529 1715 585
H
POWER RANGE AT 690VAC

5 SD75S0180 6BCD 160 250 180 132 200 150 225


SD75S0210 6BCD 200 300 210 160 250 170 255
SD75S0250 6BCD 250 350 250 200 300 210 315
6 SD75S0310 6BCD 315 400 310 250 350 260 390
SD75S0400 6BCD 355 450 400 315 400 320 480
SD75S0480 6BCD 450 600 480 355 450 385 578
7
SD75S0570 6BCD 560 700 570 450 600 460 690
SD75S0680 6BCD 630 900 680 560 700 550 825
8
SD75S0825 6BCD 800 1000 825 630 900 660 990
SD75S0930 6BCD 900 1200 930 800 1000 750 1125
W
SD75S1050 6BCD 1000 1400 1050 900 1200 840 1260
SD75S1200 6BCD 1200 1600 1200 1000 1400 950 1425 D
FRAMES 1 TO 8
SD75S1400 6BCD 1400 1800 1400 1200 1600 1140 1710
>8 SD75S1550 6BCD 1500 2000 1550 1400 1800 1270 1905
SD75S1750 6BCD 1700 2200 1750 1500 2000 1420 2130
SD75S1850 6BCD 1800 2400 1850 1700 2200 1500 2250
SD75S2200 6BCD 2100 2750 2200 1800 2400 1800 2700
SD75S2500 6BCD 2200 3000 2500 2100 2750 2000 3000

22 NOTES [1] Consult availability with Power Electronics.


23
POWER ELECTRONICS OUR PRODUCTS

SD750SP SD750SP Series


Reduce your levelized cost of water. goes one step ahead
keeping the family
For energy applications the SD750SP ensures your investment unique characteristics.

1
on new and retrofit projects.

Solar
Pumping
1,5kW to 1000kW 540 Vdc Up to 50ºC
to 1000 Vdc Power Electronics has a strong commitment to reduce the levelized
cost of water (LCoW) by offering upgraded energy saving solutions.
Synergies between our Industrial and Solar Divisions have come

2
together in the SD750SP SOLAR POWER – SD750SP.

Solar
Assisted
SD750SP is connected simultaneously to the mains (AC) and PV
field (DC). The AC input voltage determines the SD750SP DC bus
Frame 7 voltage and therefore the required DC voltage of the strings. The
maximum energy produced at the fixed DC voltage depends on

3
the number of PV panels connected in series.

Self-Suffient
Operation
The SD750SP is only connected to the PV field, generating the
necessary power to start and speed-up the pump. The minimum
power requi-red depends on the hydraulic response of the
complete pump-load system.

The SD750SP is a customized SD750 VSD with increased DC range,


adapted to work with AC or DC or hybrid supply. The SD750SP has
an upgraded firmware also able to find the MPP to maximize the
performance running in solar mode.

Optionally Solar Kits with Diode, DC-protections, disconnection and


filtering are available. Our engineering and consulting department will
support you with PV sizing and SD750SP selection. A fully integration
in a cabinet is also ready to which leads to easy installation and
commissioning.

24 Frame 6 Frame 4
25
POWER ELECTRONICS OUR PRODUCTS

SD750SP
INPUT POWER RANGE [1] 1.5kW – 1000kW COMMUNICATION USB port
STANDARD HARDWARE RS485 port
VOLTAGE RANGE AC 380 – 480 Vac (±10%),
Ethernet
VOLTAGE RANGE DC 540 – 1000Vdc (Frames 1 and 2 up to 830Vdc) Optical fiber
OPTIONAL HARDWARE Communication Cards
INPUT FREQUENCY 50Hz/60Hz (±6%)
Modbus-RTU
INPUT RECTIFIER TECHNOLOGY Diode-Diode Frames 1 and 2 / Thyristor-Diode Frames 3 to 8 STANDARD PROTOCOL Ethernet (Modbus TCP)
DISPLACEMENT POWER FACTOR (DPF = cos Φ ) ≥ 0.98 Profibus-DP
POWER FACTOR (PF= I1/Irms· cos Φ) ≥ 0.91 OPTIONAL PROTOCOL Ethernet IP
MOMENTARY POWER LOSS > 2s (depending on the load inertia) ProfiNet
Second environment (Industrial): (C3 Standard) CONTROL PANEL TYPE Removable
EMC INPUT FILTER First environment (Domestic): C2 (Optional). C1 consult Power Electronics LENGTH 3 meters and 5 meters (optional)
Optional IT filter CONNECTION USB
HARMONICS FILTER Choke coils 3% impedance LED RUN: Motor receiving power supply
CURRENT THD (%) < 40% VISUALIZATION LEDS LED FAULT: Flashing displays that a fault has occurred
REGENERATIVE NO LCD screen
OUTPUT OUTPUT FREQUENCY [2] 0...599Hz Keypad with 68 keys to control and configure the drive, start and stop / reset
LCD DISPLAY Independent memory
OVERLOAD CAPACITY Constant torque: 125% during 30s at 50ºC
Wi-Fi communication module (optional)
EFFICIENCY (At full load) ≥98% Average current and 3-phase motor current
V/Hz Average voltage and 3-phase motor voltage
VECTOR CONTROL DISPLAY INFORMATION Average input voltage and 3-phase input voltage
CONTROL METHOD Open Loop. PWM speed control / torque, AVC: speed control / torque 3-phase motor input and output frequency
Close Loop (Encoder): PWM speed control / torque, AVC: speed control / torque DC Bus Voltage
PMSM I/f, sensorless and HEPOL (High Efficiency Performance Open Loop) Drive Status
CARRIER FREQUENCY 4 to 8kHz – PEWave Speed, Torque, Power, Power Factor of the motor
OUTPUT DV/DT FILTER 500 to 800V/µs Register of total and partial drive running time with reset function (hours)
Register of total and partial drive energy consumption with reset function (kWh)
OUTPUT CABLE LENGTH [3] USC 300m, SC 150m
Relay status
DYNAMIC BRAKE External B150 Dynamic Brake (Integrated in Frames 1 and 2)
Digital inputs / PTC status
ENVIRONMENTAL OPERATION AMBIENT TEMPERATURE Minimum: -20°C Maximum: +50°C Output comparator status
Minimum: -40°C Maximum: +70°C OTHERS Analogue inputs and sensor values
RATINGS STORAGE TEMPERATURE
ALTITUDE 1000m Analogue outputs value
POWER ALTITUDE DERATING [1] > 1000m, 1% PN(kW) per 100m; 4000m maximum Motor and equipment overload status
IGBT and rectifier temperature
AMBIENT HUMIDITY <95%, non-condensing
Fault history (last 6 faults)
DEGREE OF PROTECTION IP20[4], IP54[5], IP42[6]
Real time clock
Amplitude: ± 1mm (2Hz-13.2Hz), ± 0.075mm (13.2Hz-57Hz) Perpetual calendar
VIBRATION Acceleration: 6.86m/s² (13.2Hz-57Hz), 9.8m/s² (57Hz-150Hz)
REGULATIONS CERTIFICATIONS CE, cTick, UL[7], cUL[7]
HEATING RESISTORS Optional
ELECTROMAGNETIC EMC Directive (2004/108/CE)
PROTECTIONS Rotor Locked, Motor overload (thermal model), Output current limit, Phase
COMPATIBILITY IEC/EN 61800-3
MOTOR PROTECTIONS current imbalance, Phase voltage imbalance, Motor overtemperature (PT100
signal), Speed Limit, Torque Limit LVD Directive (2006/95/CE)
IGBT’s Overload, Input Loss, Low Input Voltage, High Input Voltage, DC Bus IEC/EN 61800-2 General requirements
DESIGN
Voltage Limit, DC Bus Low Voltage, High Supply Frequency, Low Supply IEC/EN 61800-5-1 Safety
AND CONSTRUCTION
DRIVE PROTECTIONS Frequency, IGBT Temperature, Heat-sink overtemperature, Power supply IEC/EN 60146-1-1 Semiconductors
fault, Drive thermal model, Ground Fault, Software and Hardware fault, IEC 60068-2-6 – Vibration
Analog Input signal loss (speed reference loss), Safe stop / Emergency stop
FUNCTIONAL SAFETY IEC/EN 61800-5-2 Safety Stop (STO)
HARDWARE DIGITAL INPUTS 6 programmable, Active high (24Vdc). Isolated power supply
DIGITAL OUTPUTS 3 programmable changeover relays (250Vac, 8A or 30Vdc, 8A)
3 programmable differential inputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and
ANALOGUE INPUT
±10Vdc, PT100 (optically isolated)
ANALOGUE OUTPUTS 2 isolated programmable outputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc
ENCODER INPUTS (Optional) 1 differential encoder input. Voltage inputs from 5 to 24Vdc
+24Vdc user power supply, (Max. 180 mA) regulated and short-circuit protected
USER POWER SUPPLY +10Vdc user power supply, (Max. 2 potentiometers R= 1 k) regulated and
short-circuit protected
Digital I/O board:
5 Digital Inputs: Programmable inputs and active high (24Vdc). Optically isolated.
5 Digital Outputs: programmable multi-function relays.
I/O EXTENSION BOARD
Analogue I/O board:
2 Analogue Inputs: Programmable and differential input.
2 Analogue Outputs: Programmable outputs in voltage / current.
EXTERNAL POWER SUPPLY 24Vdc External Power Supply
SD CARD Port for an external SD Card. Data Logging, events registration
NOTES [1] Consult availabilty with Power Electronics. [5] Applicable to the electronics.
[2] For operation frequencies higuer than 100Hz consult Power Electronics. [6] Applicable to the electronics.
26 [3] SC: Shielded cable, USC: Unshielded Cable. Follow Power Electronics ins-
tallation reommendations. For greater cable lenghts, consult Power Electronics.
[7] In certification process.
27
[4] Available for 380–480Vac up to frame 4.
POWER ELECTRONICS OUR PRODUCTS

SD750SP CONFIGURATION TABLE DIMENSIONS ANS WEIGHTS


A B C D FRAME W D H WEIGHT (kg)
SD750 OUTPUT
INPUT DEGREE OF GROUNDING > 4000 METER 1 190 273 507 15
SERIES CURRENT
VOLTAGE PROTECTION CONNECTION (above sea level) 2 296 323 510 26
SD750 3 301 358 854 67.5
SD75P 0006 6A 5 380-480 Vac 2 IP20 S TT/TN S Not needed
SP 4 320 466 1249 94
5 431 529 1716 200
... ... 5 IP54 T IT A Needed 6 780 529 1715 335
7 1132 529 1715 479
8 1482 529 1715 585
1800 1800 A 4 IP42 H

SD750SP STANDARD RATINGS


"Operating Temperature 50 ºC "Operating Temperature 50 ºC
AC POWER" DC POWER"
FRAME CODE Imput I(A) DC
Power (kW) 400 150% Overloading
I (A) Nominal Input I(A) DC 125% Overloading
VCA (A) 60s
30s
SD75P0006 5BCD 6 2,2 9 6 8
W
SD75P0009 5BCD 9 4 14 9 11
1 SD75P0012 5BCD 12 5,5 18 12 15 D
FRAMES 1 TO 8
SD75P0018 5BCD 18 7,5 27 18 23
SD75P0024 5BCD 24 11 36 24 30
SD75P0032 5BCD 32 15 48 32 40
2 SD75P0038 5BCD 38 18,5 57 38 48
SD75P0048 5BCD 48 22 72 48 60
SD75P0060 5BCD 60 30 90 60 75
SD75P0075 5BCD 75 37 113 75 94
3
SD75P0090 5BCD 90 45 135 90 113
400 Vca - 565Vcc

SD75P0115 5BCD 115 55 173 115 144


SD75P0150 5BCD 150 75 225 150 188
4
SD75P0170 5BCD 170 90 255 170 213
SD75P0210 5BCD 210 110 315 210 263
5 SD75P0250 5BCD 250 132 375 250 313
SD75P0275 5BCD 275 150 413 275 344
SD75P0330 5BCD 330 160 495 330 413
6 SD75P0370 5BCD 370 220 555 370 463
SD75P0460 5BCD 460 250 690 460 575
SD75P0580 5BCD 580 315 870 580 725
7 SD75P0650 5BCD 650 355 975 650 813
SD75P0720 5BCD 720 400 1080 720 900
SD75P0840 5BCD 840 450 1260 840 1050
8 SD75P0925 5BCD 925 500 1388 925 1156
SD75P0990 5BCD 990 560 1485 990 1238
SD75P1150 5BCD 1150 630 1725 1150 1438
SD75P1260 5BCD 1260 710 1890 1260 1575
>8 SD75P1440 5BCD 1440 800 2160 1440 1800
SD75P1580 5BCD 1580 900 2370 1580 1975
SD75P1800 5BCD 1800 1000 2700 1800 2250

28 29
POWER ELECTRONICS OUR PRODUCTS

SD750FR SD750FR Series


Reduce your energy bills goes one step ahead
keeping the family
and increase the process unique characteristics.

1
performance at the same time.

Active Front
110kW - 2200kW 380-480Vac Up to 50ºC
End Technology
690 Vac

2 Energy Regeneration
4 quadrand operation

3 Low Harmonics
THDI <5%

Based on the latest Active Front End technology, they are able to:
regenerate the braking energy, reduce the THDi<5%[1], adjust the cosine
phi and keep it constant at any load condition, and keep the motor
voltage constant even when high input voltage drops occur.

30 NOTES [1] Harmonics are below the limits defined in IEEE519 for all ISC/IL.
31
POWER ELECTRONICS OUR PRODUCTS
HARDWARE Digital inputs 6 programmable, Active high (24Vdc), Isolated power supply
SD750FR Digital outputs 3 programmable changeover relays (250Vac, 8A or 30Vdc, 8A)
3 programmable differential inputs. 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc, PT100.
Analogue input
110kW – 2200kW (Optically isolated)
INPUT Power range [1]
Analogue outputs Two isolated programmable outputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc
Voltage range 380 - 480Vac (±10%), 690 (-5/+10%)
Encoder inputs (optional) One differential encoders input. Voltages inputs from 5 to 24Vdc
Input frequency 50Hz/60Hz (±6%) +24Vdc user power supply (Max 180mA) regulated and short-circuit protected
User power supply
Input rectifier technology IGBT +10Vdc user power supply (Max 2 potentiometers R= 1 kΩ) regulated and short-circuit
Rectifier bridge switching Digital I/O board:
2.8kHz 5 Digital Inputs: Programmable inputs and active high (24Vdc). Optically isolated.
frequency
5 Digital Outputs: programmable multi-function relays.
Displacement power factor 1 (factory settings) I/O Extension board (optional)
Analogue I/O board:
(DPF = cos Φ ) 0.90 leading ... 0.90 lagging (adjustable)
2 Analogue Input: Programmable and differential input.
Power factor (PF= i1/irms · cos 2 Analogue Output: Programmable outputs in voltage / current.
≥ 0.98
φ) External power supply (optional) 24 V External Power Supply integrated
Momentary power loss > 2sec (depending on the load inertia) SD card Port for an external SD Card. Data Logging, events registration.
Second environment (Industrial): C3 Standard. COMMUNICATIONS USB port
EMC input filter First environment (Domestic): C2 (Optional), C1 consult with Power Electronics. Standard hardware RS485 port
Harmonics filter LCL Ethernet
Optical fiber
Current thd (%) < 3% / 5% [2] Optional hardware
Communication boards
Regenerative Yes – 4 quadrant operation Modbus-RTU
Standard protocol
OUTPUT Output frequency [3] 0... 599Hz Ethernet (Modbus TCP)
Constant torque/heavy duty: 150% during 60 sec at 50ºC Profibus-DP
Overload capacity Variable torque/normal duty: 120% during 60 sec at 40ºC. Optional protocol Ethernet IP
Efficiency (at full load) ≥97% ProfiNet
V/Hz CONTROL PANEL Type Removable
VECTOR CONTROL Length 3 meters (optional)
Control method Open Loop: PMC speed / torque control, AVC: speed / torque control Connection USB
Close Loop (Encoder): PMC speed / torque control, AVC: speed / torque control LED RUN: Motor receiving power supply
Visualization leds
PMSM I/f, Sensorless and HEPOL (High Efficiency Performance Open Loop) LED FAULT: Flashing displays that a fault has occurred
Carrier frequency 4 to 8kHz – PEWave LCD Screen
LCD display Keypad with 8 keys to control and configure the drive, start and stop/reset
Output dV/dt filter 500 - 800 V/µs [3]
Independent memory
Output cable length [4] USC 300m, SC 150m Average current and 3-phase motor current
Dynamic brake - Average voltage and 3-phase motor voltage
Average input voltage and 3-phase input voltage
ENVIRONMENTAL Minimum: -20°C; Maximum: +50°C (Heavy Duty) Display information
Operation ambient temperature 3-phase input and output frequency
CONDITIONS Minimum: -20°C; Maximum: +40°C (Normal Duty)
DC Bus Voltage
Storage temperature Minimum: -40°C; Maximum: +70°C Drive Status
Altitude 1000m Real time clock
Power altitude derating [1] >1000m, 1% PN (kW) per 100m; 4000m maximum (for higher altitude consult with PE) Perpetual calendar
Ambient humidity <95%, non-condensing Speed, Torque, Power, Power factor of motor
Degree of protection IP54 [5], IP42 [6], Marine series adapted (IP44/IP54, under request) Register of total and partial drive running time with reset function. (hours)
Amplitude: ± 1mm (2Hz-13.2Hz), ± 0.075mm (13.2Hz-57Hz) Register of total and partial drive energy consumption with reset function (kWh)
Vibration Acceleration: 6.86m/s² (13.2Hz-57Hz), 9.8m/s² (57Hz-150Hz) Relay status
Others Digital inputs / PTC status
Heating resistors Optional Output comparator status
Rotor locked, Motor overload (thermal model), Output current limit, Phase current imbalance, Analogue inputs and sensor values
PROTECTIONS Motor protections Phase voltage imbalance, Motor over-temperature (PT100 signal), Speed limit Torque limit. Analogue output value
IGBT’s overload, Input phase loss, Low input voltage, High input voltage, DC Bus voltage limit, Motor overload and equipment status
Low DC Bus voltage, High input frequency, Low input frequency, IGBT temperature, Heat- Drive and rectifier temperature
Drive protections sink over-temperature, Power supply fault, Drive thermal model, Ground fault, Software and Fault history (last 6 faults)
Hardware fault, Analogue input signal loss (speed reference loss), Safe stop/Emergency Stop REGULATIONS Certifications CE, cTick, UL[7], cUL[7], Marine certifications (under request)
EMC Directive (2004/108/CE)
Electromagnetic compatibility
IEC/EN 61800-3
LVD Directive (2006/95/CE)
IEC/EN 61800-2 General requirements
Design and construction IEC/EN 61800-5-1 Safety
IEC/EN 60146-1-1 Semiconductor converters
IEC60068-2-6 – Vibration
Functional safety IEC/EN 61800-5-2 Safety Stop (STO)

NOTES [1]: Consult with Power Electronics for other configurations. [4]: SC: Shielded cable, USC: Unshielded Cable. Follow Power Electronics installation
[2]: THDi < 3% (THDv = 0%). Harmonics are below the limits recommendations. For greater cable lengths, consult Power Electronics.
32 defined in IEEE519 for all Isc / IL.
[3]: For operation frequencies higher than 100Hz consult
[5]: Applicable to the electronics.
[6]: For stand-alone models.
33
Power Electronics. [7]: Certification in process.
POWER ELECTRONICS OUR PRODUCTS

SD750FR CONFIGURATION TABLE


A B C D Operation temperature 40°C Operation temperature 50°C
SD750 ND OUTPUT
INPUT DEGREE OF GROUNDING > 4000 METER NORMAL DUTY HEAVY DUTY
SERIES CURRENT OVERLOAD
VOLTAGE PROTECTION CONNECTION (above sea level) FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A)
SD75F SD750FR 0260 260A 5 380-480 5 IP54 S TT/TN S Not needed (kW) (hp) Rated (kW) (hp) Rated
SD75F0260 5BCD 132 200 217 110 150 175 263
5 SD75F0320 5BCD 160 250 267 132 200 208 313
… … 6 690 4 IP42 T IT A Needed
SD75F0340 5BCD 200 270 283 150 220 229 344
SD75F0400 5BCD 220 300 333 160 250 275 413

POWER RANGE AT 480VAC


3100 3100A 6 SD75F0450 5BCD 250 350 375 220 300 308 463
SD75F0570 5BCD 315 400 475 250 350 383 575
SD75F0700 5BCD 400 550 583 315 450 483 725
SD750FR STANDARD RATINGS 7 SD75F0800 5BCD 450 650 667 355 500 542 813
SD75F0900 5BCD 500 700 750 400 550 600 900
Operation temperature 40°C Operation temperature 50°C SD75F1050 5BCD 560 800 875 450 700 700 1050
NORMAL DUTY HEAVY DUTY OVERLOAD 8 SD75F1140 5BCD 630 900 950 500 750 771 1157
FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A) SD75F1230 5BCD 710 940 1025 560 800 825 1238
(kW) (hp) Rated (kW) (hp) Rated SD75F1400 5BCD 800 1000 1167 630 900 958 1438
SD75F0260 5BCD 132 200 260 110 150 210 315 SD75F1550 5BCD 900 1250 1292 710 1000 1050 1575
5 SD75F0320 5BCD 160 250 320 132 200 250 375 SD75F1800 5BCD 1000 1400 1500 800 1150 1200 1800
SD75F0340 5BCD 200 270 340 150 220 275 413 >8 SD75F1950 5BCD 1100 1500 1625 900 1250 1317 1975
SD75F0400 5BCD 220 300 400 160 250 330 495 SD75F2250 5BCD 1200 1750 1875 1000 1450 1500 2250
POWER RANGE AT 400VAC

6 SD75F0450 5BCD 250 350 450 220 300 370 555 SD75F2750 5BCD 1500 2200 2292 1200 1750 1833 2750
SD75F0570 5BCD 315 400 570 250 350 460 690 SD75F3100 5BCD 1750 2450 2583 1400 2000 2083 3125
SD75F0700 5BCD 400 550 700 315 450 580 870
7 SD75F0800 5BCD 450 650 800 355 500 650 975
SD75F0900 5BCD 500 700 900 400 550 720 1080 Operation temperature 40°C Operation temperature 50°C
SD75F1050 5BCD 560 800 1050 450 700 840 1260 NORMAL DUTY HEAVY DUTY OVERLOAD
FRAME CODE
8 SD75F1140 5BCD 630 900 1140 500 750 925 1388 Motor power Motor power I(A) Motor power Motor power I(A) (A)
SD75F1230 5BCD 710 940 1230 560 800 990 1485 (kW) (hp) Rated (kW) (hp) Rated
SD75F1400 5BCD 800 1000 1400 630 900 1150 1725 SD75F0160 6BCD 132 200 160 110 150 130 195
SD75F1550 5BCD 900 1250 1550 710 1000 1260 1890 5 SD75F0180 6BCD 160 250 180 132 200 150 225
SD75F1800 5BCD 1000 1400 1800 800 1150 1440 2160 SD75F0210 6BCD 200 300 210 160 250 170 255
>8 SD75F1950 5BCD 1100 1500 1950 900 1250 1580 2370 SD75F0250 6BCD 250 350 250 200 300 210 315

POWER RANGE AT 690VAC


SD75F2250 5BCD 1200 1750 2250 1000 1450 1800 2700 6 SD75F0310 6BCD 315 400 310 250 350 260 390
SD75F2750 5BCD 1500 2200 2750 1200 1750 2200 3300 SD75F0400 6BCD 355 450 400 315 400 320 480
SD75F3100 5BCD 1750 2450 3100 1400 2000 2500 3750 SD75F0480 6BCD 450 600 480 355 450 385 578
7
SD75F0570 6BCD 560 700 570 450 600 460 690
Operation temperature 40°C Operation temperature 50°C SD75F0680 6BCD 630 900 680 560 700 550 825
8
NORMAL DUTY HEAVY DUTY OVERLOAD SD75F0825 6BCD 800 1000 825 630 900 660 990
FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A) SD75F0930 6BCD 900 1200 930 800 1000 750 1125
(kW) (hp) Rated (kW) (hp) Rated SD75F1050 6BCD 1000 1400 1050 900 1200 840 1260
SD75F0260 5BCD 132 200 236 110 150 191 286 SD75F1200 6BCD 1200 1600 1200 1000 1400 950 1425
5 SD75F0320 5BCD 160 250 291 132 200 227 341 SD75F1400 6BCD 1400 1800 1400 1200 1600 1140 1710
SD75F0340 5BCD 200 270 309 150 220 250 375 >8 SD75F1550 6BCD 1500 2000 1550 1400 1800 1270 1905
SD75F0400 5BCD 220 300 364 160 250 300 450 SD75F1750 6BCD 1700 2200 1750 1500 2000 1420 2130
POWER RANGE AT 440VAC

6 SD75F0450 5BCD 250 350 409 220 300 336 505 SD75F1850 6BCD 1800 2400 1850 1700 2200 1500 2250
SD75F0570 5BCD 315 400 518 250 350 418 627 SD75F2200 6BCD 2100 2750 2200 1800 2400 1800 2700
SD75F0700 5BCD 400 550 636 315 450 527 791 SD75F2500 6BCD 2200 3000 2500 2100 2750 2000 3000
7 SD75F0800 5BCD 450 650 727 355 500 591 886
SD75F0900 5BCD 500 700 818 400 550 655 982
SD75F1050 5BCD 560 800 955 450 700 764 1145
8 SD75F1140 5BCD 630 900 1036 500 750 841 1262
SD75F1230 5BCD 710 940 1118 560 800 900 1350
SD75F1400 5BCD 800 1000 1273 630 900 1045 1568
SD75F1550 5BCD 900 1250 1409 710 1000 1145 1718
SD75F1800 5BCD 1000 1400 1636 800 1150 1309 1964
>8 SD75F1950 5BCD 1100 1500 1773 900 1250 1436 2155
SD75F2250 5BCD 1200 1750 2045 1000 1450 1636 2455
SD75F2750 5BCD 1500 2200 2500 1200 1750 2000 3000
34 SD75F3100 5BCD 1750 2450 2818 1400 2000 2273 3409 35
POWER ELECTRONICS OUR PRODUCTS

DIMENSIONS ANS WEIGHTS


FRAME W D H WEIGHT (kg)
5 595 730 2000 350
6 945 730 2000 700
7 1295 730 2000 1000
8 1645 730 2000 1200

W
FRAMES 5 TO 8
D
Frame 6

Frame 7

NOTES [1] For frames >8 consult Power Electronics.

36 37
POWER ELECTRONICS OUR PRODUCTS

SD750K
Keeps the advanced family SD750K Series goes
one step ahead
features reducing up to 2.5 keeping the family
unique characteristics.
times the size.

110kW - 2200kW 380-480Vac


525 Vac
690 Vac
Up to 50ºC

1 Space Saving
When the space saving is the must, the SD750
Kompakt series with a power density up to
2200kW is your suitable solution.

2 IP00 and
IP20 option
Inspired by the contactors wiring concept, it has a
top input power and a bottom output motor cable.
The drive unit and the input chokes are delivered
together with a IP00 degree of protection.

3 Built-In dv/dt Filter


Inspired by the contactors wiring concept, it has a
top input power and a bottom output motor cable.
The drive unit and the input chokes are delivered
together with a IP00 degree of protection.

38 39
POWER ELECTRONICS OUR PRODUCTS
HARDWARE Digital inputs 6 programmable, Active high (24Vdc), Isolated power supply
SD750K Digital outputs 3 programmable changeover relays (250Vac, 8A or 30Vdc, 8A)
3 programmable differential inputs. 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc, PT100.
Analogue input
110kW - 2200kW (Optically isolated)
INPUT Power range [1]
Analogue outputs One isolated programmable outputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc
Voltage range 380 - 480Vac ( 10%), 525 (-5/+10%), 600 - 690 (-5/+10%)
Encoder inputs (optional) Two differential encoders input. Voltages inputs from 5 to 24Vdc
Input frequency 50Hz/60Hz (±6%) +24Vdc user power supply (Max 180mA) regulated and short-circuit protected
Input rectifier technology Diode-Diode F1-F2/Thyristor-Diode F3-F11 (multipulse available [1]) User power supply +10Vdc user power supply (Max 2 potentiometers R= 1 kΩ) regulated and short-circuit
protected
Displacement power factor ≥ 0.98 Digital I/O board:
(DPF = cos Φ )
5 Digital Inputs: Programmable inputs and active high (24Vdc). Optically isolated.
Power factor
≥ 0.91 5 Digital Outputs: programmable multi-function relays.
(PF= i1/irms · cos φ) I/O Extension board (optional)
Analogue I/O board:
Momentary power loss > 2sec (depending on the load inertia) 2 Analogue Input: Programmable and differential input.
Second environment (Industrial): C3 Standard. 2 Analogue Output: Programmable outputs in voltage / current.
EMC input filter First environment (Domestic): C2 (Optional), C1 consult with Power Electronics. External power supply (optional) 24 V External Power Supply integrated
IT filter optional SD card Port for an external SD Card. Data Logging, events registration.
Harmonics filter LCL COMMUNICATIONS USB port
Current thd (%) <40% Standard hardware RS485 port
Ethernet
Regenerative No
Optical fiber
0... 599Hz Optional hardware Communication boards
OUTPUT Output frequency [2]

Constant torque/heavy duty: 150% during 60 sec at 50ºC Modbus-RTU


Overload capacity Standard protocol Ethernet (Modbus TCP)
Variable torque/normal duty: 120% during 60 sec at 40ºC.
Efficiency (at full load) ≥98% Profibus-DP
Optional protocol Ethernet IP
V/Hz
ProfiNet
VECTOR CONTROL
Control method Open Loop: PMC speed / torque control, AVC: speed / torque control CONTROL PANEL Type Removable
Close Loop (Encoder): PMC speed / torque control, AVC: speed / torque control Length 3 meters (optional)
PMSM I/f, Sensorless and HEPOL (High Efficiency Performance Open Loop)
Connection USB
Carrier frequency 4 to 8kHz – PEWave
LED RUN: Motor receiving power supply
500 - 800 V/µs Visualization leds LED FAULT: Flashing displays that a fault has occurred
Output dV/dt filter
Output cable length [3] USC 300m, SC 150m
LCD Screen
Dynamic brake External B150 Dynamic Brake (Frames 1 and 2 integrated) LCD display Keypad with 8 keys to control and configure the drive, start and stop/reset
ENVIRONMENTAL Minimum: -20°C; Maximum: +50°C (Heavy Duty) Independent memory
Operation ambient temperature Minimum: -20°C; Maximum: +40°C (Normal Duty)
CONDITIONS Average current and 3-phase motor current
Storage temperature Minimum: -40°C; Maximum: +70°C
Average voltage and 3-phase motor voltage
Altitude 1000m Average input voltage and 3-phase input voltage
>1000m, 1% PN (kW) per 100m; 4000m maximum (for higher altitude consult with PE) Display information 3-phase input and output frequency
Power altitude derating [1]
Ambient humidity <95%, non-condensing DC Bus Voltage
Degree of protection IP00 [5], IP20 [6], Marine series adapted (IP44/IP54, under request) Drive Status
Amplitude: ± 1mm (2Hz-13.2Hz), ± 0.075mm (13.2Hz-57Hz) Real time clock
Vibration Acceleration: 6.86m/s² (13.2Hz-57Hz), 9.8m/s² (57Hz-150Hz) Perpetual calendar
Speed, Torque, Power, Power factor of motor
Heating resistors Optional
Register of total and partial drive running time with reset function. (hours)
PROTECTIONS Rotor locked, Motor overload (thermal model), Output current limit, Phase current imbalance, Register of total and partial drive energy consumption with reset function (kWh)
Motor protections Phase voltage imbalance, Motor over-temperature (PT100 signal), Speed limit Torque limit. Relay status
IGBT’s overload, Input phase loss, Low input voltage, High input voltage, DC Bus voltage limit, Others Digital inputs / PTC status
Low DC Bus voltage, High input frequency, Low input frequency, IGBT temperature, Heat- Output comparator status
Drive protections sink over-temperature, Power supply fault, Drive thermal model, Ground fault, Software and Analogue inputs and sensor values
Hardware fault, Analogue input signal loss (speed reference loss), Safe stop/Emergency Stop Analogue output value
Motor overload and equipment status
Drive and rectifier temperature
Fault history (last 6 faults)
REGULATIONS Certifications CE, cTick, UL[4], cUL[4], Marine certifications (under request)
EMC Directive (2004/108/CE)
Electromagnetic compatibility IEC/EN 61800-3
LVD Directive (2006/95/CE)
IEC/EN 61800-2 General requirements
Design and construction IEC/EN 61800-5-1 Safety
IEC/EN 60146-1-1 Semiconductor converters
IEC60068-2-6 – Vibration
Functional safety IEC/EN 61800-5-2 Safety Stop (STO)

NOTES [1]: Consult availability with Power Electronics.


[2]: For operation frequencies higher than 100Hz consult Power Electronics.
40 [3]: SC: Shielded cable, USC: Unshielded Cable. Follow Power Electronics installation
recommendations. For greater cable lengths, consult Power Electronics.
41
[4]: Certification in process.
POWER ELECTRONICS OUR PRODUCTS

SD750K CONFIGURATION TABLE


A B C D Operation temperature 40°C Operation temperature 50°C
SD750 ND OUTPUT GROUNDING > 4000 METER
INPUT DEGREE OF NORMAL DUTY HEAVY DUTY OVERLOAD
SERIES CURRENT CONNECTION (above sea level)
VOLTAGE PROTECTION FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A)
SD750 (kW) (hp) Rated (kW) (hp) Rated
SD75K 0260 260A 5 380-480 0 IP00 S TT/TN S Not needed
Kompakt
SD75K0260 5BCD 132 200 217 110 150 175 263
1 SD75K0320 5BCD 160 250 267 132 200 208 313
… … 6 600-690 2 IP20 T IT A Needed
SD75K0340 5BCD 200 270 283 150 220 229 344
SD75K0400 5BCD 220 300 333 160 250 275 413

POWER RANGE AT 480VAC


3100 3100A 7 525 2 SD75K0450 5BCD 250 350 375 220 300 308 463
SD75K0570 5BCD 315 400 475 250 350 383 575
SD75K0700 5BCD 400 550 583 315 450 483 725
3 SD75K0800 5BCD 450 650 667 355 500 542 813
SD750K STANDARD RATINGS SD75K0900 5BCD 500 700 750 400 550 600 900
SD75K1050 5BCD 560 800 875 450 700 700 1050
Operation temperature 40°C Operation temperature 50°C 4 SD75K1140 5BCD 630 900 950 500 750 771 1157
NORMAL DUTY HEAVY DUTY OVERLOAD SD75K1230 5BCD 710 940 1025 560 800 825 1238
FRAME CODE SD75K1400 5BCD 800 1000 1167 630 900 958 1438
Motor power Motor power I(A) Motor power Motor power I(A) (A)
SD75K1550 5BCD 900 1250 1292 710 1000 1050 1575
(kW) (hp) Rated (kW) (hp) Rated
SD75K1800 5BCD 1000 1400 1500 800 1150 1200 1800
SD75K0260 5BCD 132 200 260 110 150 210 315
>4 [1] SD75K1950 5BCD 1100 1500 1625 900 1250 1317 1975
1 SD75K0320 5BCD 160 250 320 132 200 250 375
SD75K2250 5BCD 1200 1750 1875 1000 1450 1500 2250
SD75K0340 5BCD 200 270 340 150 220 275 413
SD75K2750 5BCD 1500 2200 2292 1200 1750 1833 2750
SD75K0400 5BCD 220 300 400 160 250 330 495
POWER RANGE AT 400VAC

SD75K3100 5BCD 1750 2450 2583 1400 2000 2083 3125


2 SD75K0450 5BCD 250 350 450 220 300 370 555
SD75K0570 5BCD 315 400 570 250 350 460 690
SD75K0700 5BCD 400 550 700 315 450 580 870 Operation temperature 40°C Operation temperature 50°C
3 SD75K0800 5BCD 450 650 800 355 500 650 975 NORMAL DUTY HEAVY DUTY OVERLOAD
SD75K0900 5BCD 500 700 900 400 550 720 1080 FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A)
SD75K1050 5BCD 560 800 1050 450 700 840 1260 (kW) (hp) Rated (kW) (hp) Rated
4 SD75K1140 5BCD 630 900 1140 500 750 925 1388 SD75K0160 7BCD 110 150 160 90 125 130 195
SD75K1230 5BCD 710 940 1230 560 800 990 1485 1 SD75K0180 7BCD 132 180 180 110 150 150 225
SD75K1400 5BCD 800 1000 1400 630 900 1150 1725 SD75K0210 7BCD 150 200 210 132 180 170 255
SD75K1550 5BCD 900 1250 1550 710 1000 1260 1890 SD75K0250 7BCD 185 250 250 150 200 210 315

POWER RANGE AT 525VAC


SD75K1800 5BCD 1000 1400 1800 800 1150 1440 2160 2 SD75K0310 7BCD 220 300 310 185 250 260 390
>4 [1] SD75K1950 5BCD 1100 1500 1950 900 1250 1580 2370 SD75K0400 7BCD 280 400 400 220 300 320 480
SD75K2250 5BCD 1200 1750 2250 1000 1450 1800 2700 SD75K0480 7BCD 355 450 480 280 400 385 578
SD75K2750 5BCD 1500 2200 2750 1200 1750 2200 3300 3
SD75K0570 7BCD 400 550 570 355 450 460 690
SD75K3100 5BCD 1750 2450 3100 1400 2000 2500 3750 SD75K0680 7BCD 500 650 680 400 550 550 825
4
SD75K0825 7BCD 560 800 825 500 650 660 990
Operation temperature 40°C Operation temperature 50°C SD75K0930 7BCD 630 900 930 560 800 750 1125
NORMAL DUTY HEAVY DUTY OVERLOAD SD75K1050 7BCD 710 1000 1050 630 900 840 1260
FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A) SD75K1200 7BCD 900 1200 1200 710 1000 950 1425
(kW) (hp) Rated (kW) (hp) Rated SD75K1400 7BCD 1000 1400 1400 900 1200 1140 1710
SD75K0260 5BCD 132 200 236 110 150 191 286 >4 [1] SD75K1550 7BCD 1100 1500 1550 1000 1400 1270 1905
1 SD75K0320 5BCD 160 250 291 132 200 227 341 SD75K1750 7BCD 1250 1700 1750 1100 1500 1420 2130
SD75K0340 5BCD 200 270 309 150 220 250 375 SD75K1850 7BCD 1400 1800 1850 1250 1700 1500 2250
SD75K0400 5BCD 220 300 364 160 250 300 450 SD75K2200 7BCD 1600 2100 2200 1400 1800 1800 2700
POWER RANGE AT 440VAC

2 SD75K0450 5BCD 250 350 409 220 300 336 505 SD75K2500 7BCD 1800 2400 2500 1600 2100 2000 3000
SD75K0570 5BCD 315 400 518 250 350 418 627
SD75K0700 5BCD 400 550 636 315 450 527 791
3 SD75K0800 5BCD 450 650 727 355 500 591 886
SD75K0900 5BCD 500 700 818 400 550 655 982
SD75K1050 5BCD 560 800 955 450 700 764 1145
4 SD75K1140 5BCD 630 900 1036 500 750 841 1262
SD75K1230 5BCD 710 940 1118 560 800 900 1350
SD75K1400 5BCD 800 1000 1273 630 900 1045 1568
SD75K1550 5BCD 900 1250 1409 710 1000 1145 1718
SD75K1800 5BCD 1000 1400 1636 800 1150 1309 1964
>4 [1] SD75K1950 5BCD 1100 1500 1773 900 1250 1436 2155

42 SD75K2250 5BCD
SD75K2750 5BCD
1200
1500
1750
2200
2045
2500
1000
1200
1450
1750
1636
2000
2455
3000
NOTES [1] Consult availability with Power Electronics.
43
SD75K3100 5BCD 1750 2450 2818 1400 2000 2273 3409
POWER ELECTRONICS OUR PRODUCTS

SD750K STANDARD RATINGS DIMENSIONS ANS WEIGHTS


Operation temperature 40°C Operation temperature 50°C FRAME W D H WEIGHT (kg)
NORMAL DUTY HEAVY DUTY OVERLOAD IP00
FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A) 1 312 400 1085 78,2
(kW) (hp) Rated (kW) (hp) Rated 2 509 400 1085 148
SD75K0160 6BCD 132 180 160 110 150 130 195 3 759 400 1085 200
1 SD75K0180 6BCD 150 200 180 132 180 150 225 4 1009 400 1088 280 H
SD75K0210 6BCD 180 250 210 150 200 170 255 IP20
SD75K0250 6BCD 220 300 250 180 250 210 315 1 310 400 1340 85,5
POWER RANGE AT 600VAC

2 SD75K0310 6BCD 250 350 310 220 300 260 390 2 525 400 1341 159
SD75K0400 6BCD 355 450 400 250 350 320 480 3 759 400 1343 215,3
SD75K0480 6BCD 400 550 480 355 450 385 578 4 1025 400 1343 299,7
3
SD75K0570 6BCD 500 650 570 400 550 460 690
SD75K0680 6BCD 560 800 680 500 650 550 825
4
SD75K0825 6BCD 710 950 825 560 800 660 990
SD75K0930 6BCD 800 1100 930 710 950 750 1125 FRAMES 1 TO 4
SD75K1050 6BCD 900 1250 1050 800 1100 840 1260 W D
SD75K1200 6BCD 1000 1400 1200 900 1250 950 1425
SD75K1400 6BCD 1200 1600 1400 1000 1400 1140 1710
>4 [1] SD75K1550 6BCD 1300 1700 1550 1200 1600 1270 1905 IP00
SD75K1750 6BCD 1500 2000 1750 1300 1700 1420 2130
SD75K1850 6BCD 1600 2200 1850 1500 2000 1500 2250
SD75K2200 6BCD 1900 2500 2200 1600 2200 1800 2700
SD75K2500 6BCD 2200 2900 2500 1900 2500 2000 3000

Operation temperature 40°C Operation temperature 50°C


NORMAL DUTY HEAVY DUTY OVERLOAD
FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A)
(kW) (hp) Rated (kW) (hp) Rated
SD75K0160 6BCD 132 200 160 110 150 130 195
1 SD75K0180 6BCD 160 250 180 132 200 150 225
SD75K0210 6BCD 200 300 210 160 250 170 255
SD75K0250 6BCD 250 350 250 200 300 210 315
POWER RANGE AT 690VAC

2 SD75K0310 6BCD 315 400 310 250 350 260 390


SD75K0400 6BCD 355 450 400 315 400 320 480
SD75K0480 6BCD 450 600 480 355 450 385 578
3
SD75K0570 6BCD 560 700 570 450 600 460 690
SD75K0680 6BCD 630 900 680 560 700 550 825
4
SD75K0825 6BCD 800 1000 825 630 900 660 990
SD75K0930 6BCD 900 1200 930 800 1000 750 1125 IP20
SD75K1050 6BCD 1000 1400 1050 900 1200 840 1260
SD75K1200 6BCD 1200 1600 1200 1000 1400 950 1425
SD75K1400 6BCD 1400 1800 1400 1200 1600 1140 1710
>4 [1] SD75K1550 6BCD 1500 2000 1550 1400 1800 1270 1905
SD75K1750 6BCD 1700 2200 1750 1500 2000 1420 2130
SD75K1850 6BCD 1800 2400 1850 1700 2200 1500 2250
SD75K2200 6BCD 2100 2750 2200 1800 2400 1800 2700
SD75K2500 6BCD 2200 3000 2500 2100 2750 2000 3000

44 NOTES [1] Consult availability with Power Electronics.


45
POWER ELECTRONICS OUR PRODUCTS

MECHANICAL ACCESSORIES

ACCESORIES IP20 Connection Boxes

SD750 frames 1 to 3 have extension boxes


permitting larger cables to be terminated.
SD750 Frame 4 to 8 plinths

SD750 frames 5 and up are stand-alone drives.


They can be equipped with optional plinths
to attain 2000mm or 2200mm total height. A
SD750 through its accessories fulfils the most extended requirements of FRAME CODE
DIMENSIONS stand-alone plinth for frame 4 attaining total
the industrial sector. SD750 series offers a wide variety of communication W D H height of 1712mm is also available.
protocols, dedicated boards, filters, interface accessories, etc... that enhances 1
2
SD75EB1
SD75EB2
189
295
122
122
161
161
family features. 3 SD75EB3 300 151 168 DIMENSIONS Total drive
FRAME CODE
W D H height (mm)
CODE DESCRIPTION SD75PL0417 320 464 438.5 1712
4
SD75ET Ethernet/IP communication board SD75PL0420 320 464 468.5 2000
SD75PN Profinet communication board SD75PL0520 431 413.5 529 2000
5
SD75PB Profibus communication board SD75PL0522 431 613.5 529 2200
Encoder board SD75PL0620 786 413.5 529 2000
SD75EC 6
It allows to have 1 Differential Encoders (TTL or HTL) working from 5 to 24Vdc SD75PL0622 786 613.5 529 2200
Digital input/outputs expansion boards SD75PL0720 1132 413.5 529 2000
7
It allows to increase the number of inputs and outputs of the unit. It includes: SD75PL0722 1132 613.5 529 2200
SD75DIO
• 5 Digital Inputs optically isolated and configurable SD75PL0820 1482 413.5 529 2000
• 5 Digital Outputs (Relays) 8
SD75PL0822 1482 613.5 529 2200
Analogue inputs/outputs expansion boards
It allows to increase the number of inputs and outputs of the unit. It includes:
SD75AIO
• 2 Configurable analogue inputs
• 2 Configurable analogue outputs
SD75FO Fibre optics board. It allows to communicate several drives in master-slave configuration
SD75PT Card for 8 thermal sensors type PT100 or PT1000 (configurable)
B150 Dynamic brake
SD75DE3 Display extender kit 3 meters

COMMUNICATIONS ACCESSORIES EXTENSION BOARDS OTHER ACCESSORIES


SD750 series is compatible with the most I/O Expander Board Dynamic brake B150
commonly used communication protocols
(Profibus, Profinet, Ethernet/IP...), thanks to its Optionally, the SD750 has two input and output The Dynamic brake controls the regenerated This activation signal could also be delivered by
optional boards. expansion boards available, which allow energy for SD750 series. B150 dynamic brake the drive acquiring an optional Master-Slave mode
the converter to be integrated in any type of activates an IGBT to discharge the DC bus through braking board.
installation: external resistors when the DC voltage surpasses
Fibre Optics Board a pre-set value.
Digital expansion boards: Analogue expansion boards:
It connects and synchronizes all required drives • 5 digital inputs • 2 analogue inputs
through fibre optics. • 5 digital outputs (0-10V, 4-20mA) Current (A) Minimum Dimensions (mm)
Weight
• 2 analogue outputs REFERENCE VOLTAGE Resistance
Maximum Continuous W D H (kg)
Power Motor Control can be utilised with the Rating (Ω)
master and multiple followers all sharing Encoder Board B150 380Vac, 500Vac 300A 150A 2.4Ω
177 221 352 7
identical torque or following the same speed B150.6 690Vac 200A 100A 5.75Ω
reference. The fibre optics allows long The encoder board improves the speed
communication distance without interference. regulation thanks to the closed loop control.
They are optically isolated and have the Special filters Painting
possibility to be powered by 5Vdc or 24Vdc.
Special output and input filters are available such SD750 can include special cabinet painting.
PT100 Input Expander as sinusoidal output filter or First Environment, Customized solutions available.
C2 category input filter. For further information
The PT100 board provides extra protection to consult Power Electronics.
the motor, guaranteeing the correct operation
of the motor and the application. It allows Safety
connecting up to 8 PT100 sensors in the
equipment, permitting the monitoring of different SD750 can include safety accessories such
temperature sensors installed in the motor, or as PT100, emergency off and emergency stop
46 even for temperature process control. pushbuttons. 47
POWER ELECTRONICS OUR SECRET

We take care
of the legacy generations
Each new generation of inverters involves adapting the manufacturing lines to optimize
the production of these new devices. Power Electronics has a facility optimized for the
production of limited units from previous generations, where we manufacture current
BY POWER ELECTRONICS subcomponents adapted to equipment that is no longer in production, but which allows
for an extended life.

HE HEC HECPlus HEC DCDC HEMK

HEM

Long Term Service


We repare subcomponents or even

Our secret manufacture equivalent units in our


Dedicated Service Factory located near
our Production Plant.
The key of our success for more than Power Electronics has experience in repowering old photovoltaic plants, where
30 years, our 24/7 after sales service, we supply state-of-the-art equipment adapting its electrical characteristics to be
compatible with the existing configuration, while providing all the advantages of the
Power On Support. latest generation inverters.

48 49
POWER ELECTRONICS WARRANTY

We are here to
WARRANTY
help you
Power Electronics (the Seller) warrants that

Vertical
their Products are free of faults and defects for a
period of 3 years, valid from the date of delivery
to the Buyer. It shall be understood that a product
is free of faults and defects when its condition

Integration
and performance is in compliance with its
specification.
Scan me!
The warranty shall not extend to any Products
whose defects are due to (i) careless or
improper use, (ii) failure to observe the Seller’s
throughout the entire process instructions regarding the transport, installation,
functioning, maintenance and the storage of
We complement your spare parts strategy with our own thanks to our Dedicated Service the Products, (iii) repairs or modifications made
Factory warehouse, informing you when any of them is going to be discontinued so you by the Buyer or third party without prior written
can plan accordingly. authorization of the Seller, (iv) negligence during
the implementation of authorized repairs or
modifications, (v) if serial numbers are modified
or illegible, (vi) anomalies caused by, or connected
to, the elements coupled directly by the Buyer or
by the final customer, (vii) accidents or events
Before commissioning that place the Product outside its storage and
operational specification, viii) continued use of the
Products after identification of a fault or defect.
· Technical applications & design requirement review
· Dedicated Project Management Support The warranty excludes components that must be
· Hands on functional & safety product training replaced periodically such as Fuses + DC switch,
lamps & air filters or consumable materials
subject to normal wear and tear.

The warranty excludes external parts that are


not manufactured by the Seller under the brand of
Power Electronics.
During commissioning
The Seller undertakes to replace or to repair,
himself, at their discretion, any Product or its part
that demonstrates a fault or defect, which is in
· Dedicated commissioning teams conformance with the aforementioned terms
· Rigorous execution on through site operation of the warranty. Reasonable costs associated
with the disassembly/ assembly, transport and
customs of equipment will also be undertaken by
the Seller except in cases of approved intervention
by the Buyer and/or their representative where
cost allocation has been previously agreed.
After commissioning

· Support 24/7, 365 days a year


· Full warranty coverage with options for extension and
full preventative maintenance packages
· Advanced offerings for remote monitoring, detailed
performance reporting, and interactive portals for
tracking metrics direct with the PE Service Org

50 Power Electronics reserves the right to modify whole or part of the content of this
brochure at any time and without prior notice. May 2021. 51
POWER ELECTRONICS

HEADQUARTERS
SPAIN UNITED STATES
Polígono Pla de Carrases 1510 N. Hobson Street, Gilbert
CV-35 Exit 30, 46160 Arizona, USA
Lliria - Valencia - Spain Tel. (+001) 602-354-4890
Tel. (+34) 96 136 65 57 [email protected]
Fax (+34) 96 131 82 01 24/7 Technical Assistance Service
24/7 Technical Assistance Service Tel. (+001) 902 40 20 70
Tel. (+34) 902 40 20 70

INTERNATIONAL
ARGENTINA FRANCE PERU
Arroyo 894, 5º 51 Rue Hoche, 94200 Ivry Sur Seine. Avenida El Polo nº 670, Centro Comercial
Oficina 10 Ciudad autónoma de Paris (France) El Polo II – Oficina 603, Piso 6º, Bloque C
Buenos Aires +33(0)1 46 46 10 34 Santiago de Surco, Lima
[email protected] (+51) 979 749 772
ASIA Contact: Guillaume Mamy [email protected]
30th Floor, CATIC Plaza, 8 Cau- Contact: Gustavo Prialé
seway Road, Hong Kong SAR INDIA
Silver Jade, Off. No 03, G.F., A-Wing CTS NO. GERMANY
AUSTRALIA -188, Behind Tarun Bharat Society, Chakala, Neuseser Strasse 15, 90455
U6, 30-34 Octal St. Yatala, Brisbane, Andheri East, Mumbai, Maharashtra Nürnberg. Germany
Queensland 4118, Australia (+91) 80 6569 0489 [email protected]
(+61) 7 3386 1993 [email protected]
[email protected] SOUTH AFRICA
Central Office Park Unit 5
ITALIA
BEIJING Piazzale Cadorna, 6, 20123.
257 Jean Avenue – Centurion 0157
Xiaoying Road Chaoyang, Nº25, [email protected]
Milán Italia
Beijing City [email protected]
UNITED KINGDOM
BRAZIL JAPAN Chippenham Drive, Unit 2, Madingley Court.
Nishi-Shinbasi 2-17-2 HF Toranomon Bldg 5F. Kingston, Milton Keynes.
Avda. Robert Kennedy 2070. Sao Bernardo do
105-0003 Minato-Ku Tokio MK10 0BZ, United Kingdom
Campo. Sao Paulo
[email protected] [email protected]
(+55) 11 5891 9612 / (+55) 11 5891 9762
Contact: Stanley Han Contact (Solar division): Juan Antonio Torres
[email protected]
Contact: Fabio Cinquini
MALAYSIA PHILIPPINES
Unit 209 ZF Page 1 Bldg MBP
CHILE Level 7, Menara Milenium, Jalan Damanlela,
Pusat Bandar Damansara, Damansara Ayala Alabang, Muntinlupa.
Av. Alonso de Córdova 5870, Of. 210-211
Heigths, 50490 Kuala Lumpur W.P.
Las Condes, Santiago de Chile
(+56) 2 3223 8916
Malaysia REPÚBLICA DOMINICANA
[email protected] Ave. John F. Kennedy Núm. 7, Los Jardines,
[email protected]
Distrito Nacional, República Dominicana.
COLOMBIA MEXICO
Henry Ford n.3, Fraccionamiento Industrial IRELAND
Cl 77 9-20 Bogotá DC 20 Harcourt Street Dublin,
San Nicolás, Tlalnepantla, Estado de México
Colombia D02 H364, Irlanda
(+52) 1 55 4949 0830 / (+52) 539 08818
(+57) 322 3464855
[email protected]
[email protected]
Contact: Manuel Garay
Contact: Héctor Nuñez
March 2022

You might also like