B industrialSD750
B industrialSD750
Easy to drive
PE genetics Page. 4 — 5
Our secret
Page. 48— 50
POWER ELECTRONICS OUR GENETICS
More than
GW
of installed
AC power
Solar + Storage
+
25
of annual
GW
production
capacity
+10k
+
30
years of
of distributed products + 25 excellence
International
+30MW +50
installed in solar pump applications countries delegations
4 5
POWER ELECTRONICS OUR PRODUCTS
“Vertical
integration gives
SD
us flexibility
750
to adapt to
customers’
requirements”
6 7
POWER ELECTRONICS OUR PRODUCTS
SD750
Page. 10 — 23
VARIABLE
SPEED
Page. 24 — 29
SD750SP
Page. 30— 37
SD750FR
DRIVES
SD750K
Page. 38 — 47
8 9
POWER ELECTRONICS COMMON FEATURES OUR PRODUCTS
All our equipment
share the following
SD750
1
caracteristics
3
wiring and motor cost reduction.
Harmonics filter
High input impedance given by the 3% input chokes
protects the drive against any grid anomaly and
enhances its THDi performance in weak grids.
10 11
POWER ELECTRONICS OUR PRODUCTS
Cooling
System
5
Innovative
Level 2
Level 1
LEVEL 1
Electronics
The electronic components are completely isolated
in what is called the “electronics area”. The heat
exchange of the electronic components is separated
from the areas that cool the heat sink and the electric
filtering components, making the cooling of these
components much more efficient.
LEVEL 2
Cooling
SD750 cooling system uses efficient axial fans at low
speed which provide three main benefits:
LEVEL 3
Input filter
The input filters are enclosed separately, optimizing
their cooling capacity, degree of protection and
increasing their long life operation.
12 13
POWER ELECTRONICS OUR PRODUCTS
6 Connectivity
SD750 is compatible with the most used industrial
protocols in the market. Incorporating Modbus RTU and
Modbus TCP protocols as standard and as an option
Ethernet/IP, Profibus and ProfiNet. Maximum safety
7
With motor relay features built-in as standard the
SD750 hardware offers continuous monitoring of the
motor electric values and its temperature (PTC sensor,
and PT100). As a result, the highly advanced software
8
provides full motor and drive protection.
Advanced
Control and push buttons
Motor
Display Control
Power Electronics’ success is measured by our customer’s
Multiple drives synchronization applications satisfaction. The motor control systems developed by Power
Electronics have been designed to meet the most demanding
features. The SD750 integrates V/f control and two vector
Output filters and equipment controls: Power Motor Control (PMC) and the Advanced Vector
Control (AVC) as standard.
9
Digital inputs
Output relays
14 15
POWER ELECTRONICS OUR PRODUCTS
HARDWARE Digital inputs 6 programmable, Active high (24 Vdc), Isolated power supply
SD750 Digital outputs 3 programmable changeover relays (250 Vac, 8 A or 30 Vdc, 8 A)
3 programmable differential inputs: 0-20 mA, 4-20 mA, 0-10 Vdc and ±10 Vdc. PT100.
Analogue input
1.5kW – 2200kW (Optically isolated).
INPUT Power range [1]
Analogue outputs 2 isolated programmable outputs: 0-20 mA, 4-20 mA, 0-10 Vdc and ±10 Vdc
Voltage range 380 – 480Vac (±10%), 525 – 690Vac (-5/+10%)
Encoder inputs (optional) 1 differential encoders input. Voltages inputs from 5 to 24Vdc
Input frequency 50 Hz / 60 Hz (± 6%) +24 Vdc user power supply (Max. 180 mA) regulated and short-circuit protected
Input rectifier technology Diode-Diode F1-F2/Thyristor-Diode F3-F11 (multipulse available [1]
) User power supply +10 Vdc user power supply (Max. 2 potentiometers R=1 kΩ) regulated and short-circuit
protected
Displacement power factor ≥ 0.98 Digital I/O board:
(DPF = cos Φ )
5 Digital inputs: Programmable inputs and active high (24Vdc). Optically isolated
Power factor (PF= I1 /Irms· cos Φ) ≥ 0.91 5 Digital outputs: programmable multi-function relays
I/O Extension board (optional)
Momentary power loss > 2 seconds (depending on the load inertia) Analogue I/O board:
2 Analogue input: Programmable and differential input
Second environment (Industrial): C3 Standard.
2 Analogue output: Programmable outputs in voltage/current
EMC input filter First environment (Domestic): C2 (Optional), C1 consult with Power Electronics.
IT filter optional External power supply (optional) 24 V External power supply integrated
SD card Port for an external SD Card. Data Logging, events registration
Harmonics filter Choke coils 3% impedance
COMMUNICATION USB port
Current THD (%) < 40%
Standard hardware RS485 port
Regenerative No Ethernet
OUTPUT Output frequency [2] 0... 599 Hz Optical fibre
Optional hardware
Communication boards
Constant torque / heavy duty: 150% during 60 seconds at 50°C
Overload capacity Variable torque / normal duty: 120% during 60 seconds at 40°C Modbus-RTU
Standard protocol
Ethernet (Modbus TCP)
Efficiency (at full load) ≥ 98%
Profibus-DP
V / Hz Optional protocol Ethernet IP
VECTOR CONTROL ProfiNet
Control method Open Loop: PMC speed / torque control, AVC: speed / torque control Type Removable
CONTROL PANEL
Close Loop (Encoder): PMC speed / torque control, AVC: speed / torque control
Length 3 meters (optional)
PMSM I/f &, Sensorless and HEPOL (High Efficiency Performance Open Loop)
Connection USB
Carrier frequency 4 to 8 kHz - PEWave
LED RUN: Motor receiving power supply
500 - 800 V/µs Visualization leds
Output dV/dt filter LED FAULT: Flashing displays that a fault has occurred
Output cable length [4] USC 300 m - SC 150 m LCD screen
LCD display Keypad with 8 keys to control and configure the drive, start and stop/reset
Dynamic brake External B150 Dynamic Brake - (Frames 1 and 2 integrated)
Independent memory
ENVIRONMENTAL Minimum: -20°C Maximum: +50°C (Heavy duty) Average current and 3-phase motor current
Operation ambient temperature Minimum: -20°C Maximum: +40°C (Normal duty)
CONDITIONS Average voltage and 3-phase motor voltage
Storage temperature Minimum: -40°C Maximum: +70°C Display information Average input voltage and 3-phase input voltage
Altitude 1000 m 3-phase input and output frequency
Power altitude derating [1] >1000m, 1% PN (kW) per 100m; 4000m maximum (for higher altitude consult with PE) DC Bus Voltage
Ambient humidity <95%, non-condensing Drive status
Speed, Torque, Power, Power factor of motor
Degree of protection IP20 [5], IP54 [6], IP42 [7], Marine series adapted (IP44/IP54, under request)
Register of total and partial drive running time with reset function. (hours)
Amplitude: ± 1mm ( 2 Hz-13.2 Hz), ± 0.075 mm (13.2 Hz-57 Hz) Register of total and partial drive energy consumption with reset function (kWh)
Vibration Acceleration: 6.86 m/s2 (13.2 Hz-57 Hz), 9.8 m/s2 (57 Hz-150 Hz) Relay status
Heating resistors Optionals Digital inputs / PTC status
PROTECTIONS Rotor locked, Motor overload (thermal model), Output current limit, Phase current imbalance, Output comparator status
Motor protections Others
Phase voltage imbalance, Motor over-temperature (PT100 signal), Speed limit, Torque limit Analogue inputs and sensor values
IGBT’s overload, Input phase loss, Low input voltage, High input voltage, DC Bus voltage Analogue output value
limit, Low DC Bus voltage, IGBT temperature, Heat-sink over-temperature, Power supply Motor overload and equipment status
Drive protections fault, Drive thermal model, Ground fault, Software and Hardware fault, Analogue input Drive and rectifier temperature
signal loss (speed reference loss), Safe stop/Emergency Stop Fault history (last 6 faults)
Real time clock
Perpetual calendar
REGULATIONS Certifications CE, cTick, UL, cUL, Marine certifications (under request)
EMC Directive (2004/108/CE)
Electromagnetic compatibility
IEC/EN 61800-3
LVD Directive (2006/95/CE)
IEC/EN 61800-2 General requirements
Design and construction IEC/EN 61800-5-1 Safety
IEC/EN 60146-1-1 Semiconductor converters
IEC60068-2-6 - Vibration
Functional safety IEC/EN 61800-5-2 Safety Stop (STO)
NOTES [1] Consult availability with Power Electronics. [5] Available for 380–480Vac up to frame 4.
[2] For operation frequencies higher than 100 Hz, consult Power Electronics. [6] Applicable to the electronics.
16 [3] Valid for frames 3 to 11 depending on the SD750 rated power. For frames
1 and 2 it is available optional filter.
[4] SC: Shielded cable, USC: Unshielded Cable. Follow Power Electronics installation
[7] For stand-alone models.
17
recommendations. For greater cable lengths, consult Power Electronics.
POWER ELECTRONICS OUR PRODUCTS
18 19
POWER ELECTRONICS OUR PRODUCTS
STANDARD RATINGS
Operation temperature 40°C Operation temperature 50°C Operation temperature 40°C Operation temperature 50°C
NORMAL DUTY HEAVY DUTY OVERLOAD NORMAL DUTY HEAVY DUTY OVERLOAD
FRAME CODE FRAME CODE
Motor power Motor power I(A) Motor power Motor power I(A) (A) Motor power Motor power I(A) Motor power Motor power I(A) (A)
(kW) (hp) Rated (kW) (hp) Rated (kW) (hp) Rated (kW) (hp) Rated
SD75S0006 5BCD 2.2 3 5 1.5 2 3 6 SD75S0055 6BCD 37 50 55 30 40 42 63
SD75S0008 5BCD 4 5 7 2.2 3 5 8 SD75S0065 6BCD 45 60 65 37 50 52 78
SD75S0011 5BCD 5.5 7,5 9 4 5 8 12 4 [1] SD75S0075 6BCD 55 75 75 45 60 62 93
1 SD75S0015 5BCD 7.5 10 13 5.5 7,5 10 15 SD75S0100 6BCD 75 100 100 55 75 80 120
SD75S0024 5BCD 11 15 20 7.5 10 15 23 SD75S0120 6BCD 90 125 120 75 100 105 157
SD75S0030 5BCD 15 20 25 11 15 20 30 SD75S0160 6BCD 110 150 160 90 125 130 195
SD75S0095 5BCD 45 60 79 37 50 63 94 SD75S0400 6BCD 280 400 400 220 300 320 480
SD75S0110 5BCD 55 75 92 45 60 75 113 SD75S0480 6BCD 355 450 480 280 400 385 578
3 7
SD75S0145 5BCD 75 100 121 55 75 96 144 SD75S0570 6BCD 400 550 570 355 450 460 690
SD75S0180 5BCD 90 125 150 75 100 125 188 SD75S0680 6BCD 500 650 680 400 550 550 825
8
SD75S0200 5BCD 110 150 167 90 125 142 213 SD75S0825 6BCD 560 800 825 500 650 660 990
4
SD75S0260 5BCD 132 200 217 110 150 175 263 SD75S0930 6BCD 630 900 930 560 800 750 1125
SD75S0320 5BCD 160 250 267 132 200 208 313 SD75S1050 6BCD 710 1000 1050 630 900 840 1260
5
SD75S0400 5BCD 220 300 333 160 250 275 413 SD75S1200 6BCD 900 1200 1200 710 1000 950 1425
SD75S0450 5BCD 250 350 375 220 300 308 463 SD75S1400 6BCD 1000 1400 1400 900 1200 1140 1710
6 SD75S0570 5BCD 315 400 475 250 350 383 575 >8 SD75S1550 6BCD 1100 1500 1550 1000 1400 1270 1905
SD75S0700 5BCD 400 550 583 315 450 483 725 SD75S1750 6BCD 1250 1700 1750 1100 1500 1420 2130
SD75S0800 5BCD 450 650 667 355 500 542 813 SD75S1850 6BCD 1400 1800 1850 1250 1700 1500 2250
7 SD75S0900 5BCD 500 700 750 400 550 600 900 SD75S2200 6BCD 1600 2100 2200 1400 1800 1800 2700
SD75S1050 5BCD 560 800 875 450 700 700 1050 SD75S2500 6BCD 1800 2400 2500 1600 2100 2000 3000
SD75S1140 5BCD 630 900 950 500 750 771 1157
8
SD75S1400 5BCD 800 1000 1167 630 900 958 1438
Operation temperature 40°C Operation temperature 50°C
SD75S1550 5BCD 900 1250 1292 710 1000 1050 1575
NORMAL DUTY HEAVY DUTY OVERLOAD
SD75S1800 5BCD 1000 1400 1500 800 1150 1200 1800 FRAME CODE
SD75S1950 5BCD 1100 1500 1625 900 1250 1317 1975 Motor power Motor power I(A) Motor power Motor power I(A) (A)
>8 (kW) (hp) Rated (kW) (hp) Rated
SD75S2250 5BCD 1200 1750 1875 1000 1450 1500 2250
SD75S2750 5BCD 1500 2200 2292 1200 1750 1833 2750 SD75S0055 6BCD 45 60 55 37 50 42 63
SD75S3100 5BCD 1750 2450 2583 1400 2000 2083 3125 SD75S0065 6BCD 55 75 65 45 60 52 78
4 [1] SD75S0075 6BCD 60 90 75 55 75 62 93
SD75S0100 6BCD 90 125 100 60 90 80 120
SD75S0120 6BCD 110 150 120 90 125 105 157
SD75S0160 6BCD 132 180 160 110 150 130 195
1
on new and retrofit projects.
Solar
Pumping
1,5kW to 1000kW 540 Vdc Up to 50ºC
to 1000 Vdc Power Electronics has a strong commitment to reduce the levelized
cost of water (LCoW) by offering upgraded energy saving solutions.
Synergies between our Industrial and Solar Divisions have come
2
together in the SD750SP SOLAR POWER – SD750SP.
Solar
Assisted
SD750SP is connected simultaneously to the mains (AC) and PV
field (DC). The AC input voltage determines the SD750SP DC bus
Frame 7 voltage and therefore the required DC voltage of the strings. The
maximum energy produced at the fixed DC voltage depends on
3
the number of PV panels connected in series.
Self-Suffient
Operation
The SD750SP is only connected to the PV field, generating the
necessary power to start and speed-up the pump. The minimum
power requi-red depends on the hydraulic response of the
complete pump-load system.
24 Frame 6 Frame 4
25
POWER ELECTRONICS OUR PRODUCTS
SD750SP
INPUT POWER RANGE [1] 1.5kW – 1000kW COMMUNICATION USB port
STANDARD HARDWARE RS485 port
VOLTAGE RANGE AC 380 – 480 Vac (±10%),
Ethernet
VOLTAGE RANGE DC 540 – 1000Vdc (Frames 1 and 2 up to 830Vdc) Optical fiber
OPTIONAL HARDWARE Communication Cards
INPUT FREQUENCY 50Hz/60Hz (±6%)
Modbus-RTU
INPUT RECTIFIER TECHNOLOGY Diode-Diode Frames 1 and 2 / Thyristor-Diode Frames 3 to 8 STANDARD PROTOCOL Ethernet (Modbus TCP)
DISPLACEMENT POWER FACTOR (DPF = cos Φ ) ≥ 0.98 Profibus-DP
POWER FACTOR (PF= I1/Irms· cos Φ) ≥ 0.91 OPTIONAL PROTOCOL Ethernet IP
MOMENTARY POWER LOSS > 2s (depending on the load inertia) ProfiNet
Second environment (Industrial): (C3 Standard) CONTROL PANEL TYPE Removable
EMC INPUT FILTER First environment (Domestic): C2 (Optional). C1 consult Power Electronics LENGTH 3 meters and 5 meters (optional)
Optional IT filter CONNECTION USB
HARMONICS FILTER Choke coils 3% impedance LED RUN: Motor receiving power supply
CURRENT THD (%) < 40% VISUALIZATION LEDS LED FAULT: Flashing displays that a fault has occurred
REGENERATIVE NO LCD screen
OUTPUT OUTPUT FREQUENCY [2] 0...599Hz Keypad with 68 keys to control and configure the drive, start and stop / reset
LCD DISPLAY Independent memory
OVERLOAD CAPACITY Constant torque: 125% during 30s at 50ºC
Wi-Fi communication module (optional)
EFFICIENCY (At full load) ≥98% Average current and 3-phase motor current
V/Hz Average voltage and 3-phase motor voltage
VECTOR CONTROL DISPLAY INFORMATION Average input voltage and 3-phase input voltage
CONTROL METHOD Open Loop. PWM speed control / torque, AVC: speed control / torque 3-phase motor input and output frequency
Close Loop (Encoder): PWM speed control / torque, AVC: speed control / torque DC Bus Voltage
PMSM I/f, sensorless and HEPOL (High Efficiency Performance Open Loop) Drive Status
CARRIER FREQUENCY 4 to 8kHz – PEWave Speed, Torque, Power, Power Factor of the motor
OUTPUT DV/DT FILTER 500 to 800V/µs Register of total and partial drive running time with reset function (hours)
Register of total and partial drive energy consumption with reset function (kWh)
OUTPUT CABLE LENGTH [3] USC 300m, SC 150m
Relay status
DYNAMIC BRAKE External B150 Dynamic Brake (Integrated in Frames 1 and 2)
Digital inputs / PTC status
ENVIRONMENTAL OPERATION AMBIENT TEMPERATURE Minimum: -20°C Maximum: +50°C Output comparator status
Minimum: -40°C Maximum: +70°C OTHERS Analogue inputs and sensor values
RATINGS STORAGE TEMPERATURE
ALTITUDE 1000m Analogue outputs value
POWER ALTITUDE DERATING [1] > 1000m, 1% PN(kW) per 100m; 4000m maximum Motor and equipment overload status
IGBT and rectifier temperature
AMBIENT HUMIDITY <95%, non-condensing
Fault history (last 6 faults)
DEGREE OF PROTECTION IP20[4], IP54[5], IP42[6]
Real time clock
Amplitude: ± 1mm (2Hz-13.2Hz), ± 0.075mm (13.2Hz-57Hz) Perpetual calendar
VIBRATION Acceleration: 6.86m/s² (13.2Hz-57Hz), 9.8m/s² (57Hz-150Hz)
REGULATIONS CERTIFICATIONS CE, cTick, UL[7], cUL[7]
HEATING RESISTORS Optional
ELECTROMAGNETIC EMC Directive (2004/108/CE)
PROTECTIONS Rotor Locked, Motor overload (thermal model), Output current limit, Phase
COMPATIBILITY IEC/EN 61800-3
MOTOR PROTECTIONS current imbalance, Phase voltage imbalance, Motor overtemperature (PT100
signal), Speed Limit, Torque Limit LVD Directive (2006/95/CE)
IGBT’s Overload, Input Loss, Low Input Voltage, High Input Voltage, DC Bus IEC/EN 61800-2 General requirements
DESIGN
Voltage Limit, DC Bus Low Voltage, High Supply Frequency, Low Supply IEC/EN 61800-5-1 Safety
AND CONSTRUCTION
DRIVE PROTECTIONS Frequency, IGBT Temperature, Heat-sink overtemperature, Power supply IEC/EN 60146-1-1 Semiconductors
fault, Drive thermal model, Ground Fault, Software and Hardware fault, IEC 60068-2-6 – Vibration
Analog Input signal loss (speed reference loss), Safe stop / Emergency stop
FUNCTIONAL SAFETY IEC/EN 61800-5-2 Safety Stop (STO)
HARDWARE DIGITAL INPUTS 6 programmable, Active high (24Vdc). Isolated power supply
DIGITAL OUTPUTS 3 programmable changeover relays (250Vac, 8A or 30Vdc, 8A)
3 programmable differential inputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and
ANALOGUE INPUT
±10Vdc, PT100 (optically isolated)
ANALOGUE OUTPUTS 2 isolated programmable outputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc
ENCODER INPUTS (Optional) 1 differential encoder input. Voltage inputs from 5 to 24Vdc
+24Vdc user power supply, (Max. 180 mA) regulated and short-circuit protected
USER POWER SUPPLY +10Vdc user power supply, (Max. 2 potentiometers R= 1 k) regulated and
short-circuit protected
Digital I/O board:
5 Digital Inputs: Programmable inputs and active high (24Vdc). Optically isolated.
5 Digital Outputs: programmable multi-function relays.
I/O EXTENSION BOARD
Analogue I/O board:
2 Analogue Inputs: Programmable and differential input.
2 Analogue Outputs: Programmable outputs in voltage / current.
EXTERNAL POWER SUPPLY 24Vdc External Power Supply
SD CARD Port for an external SD Card. Data Logging, events registration
NOTES [1] Consult availabilty with Power Electronics. [5] Applicable to the electronics.
[2] For operation frequencies higuer than 100Hz consult Power Electronics. [6] Applicable to the electronics.
26 [3] SC: Shielded cable, USC: Unshielded Cable. Follow Power Electronics ins-
tallation reommendations. For greater cable lenghts, consult Power Electronics.
[7] In certification process.
27
[4] Available for 380–480Vac up to frame 4.
POWER ELECTRONICS OUR PRODUCTS
28 29
POWER ELECTRONICS OUR PRODUCTS
1
performance at the same time.
Active Front
110kW - 2200kW 380-480Vac Up to 50ºC
End Technology
690 Vac
2 Energy Regeneration
4 quadrand operation
3 Low Harmonics
THDI <5%
Based on the latest Active Front End technology, they are able to:
regenerate the braking energy, reduce the THDi<5%[1], adjust the cosine
phi and keep it constant at any load condition, and keep the motor
voltage constant even when high input voltage drops occur.
30 NOTES [1] Harmonics are below the limits defined in IEEE519 for all ISC/IL.
31
POWER ELECTRONICS OUR PRODUCTS
HARDWARE Digital inputs 6 programmable, Active high (24Vdc), Isolated power supply
SD750FR Digital outputs 3 programmable changeover relays (250Vac, 8A or 30Vdc, 8A)
3 programmable differential inputs. 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc, PT100.
Analogue input
110kW – 2200kW (Optically isolated)
INPUT Power range [1]
Analogue outputs Two isolated programmable outputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc
Voltage range 380 - 480Vac (±10%), 690 (-5/+10%)
Encoder inputs (optional) One differential encoders input. Voltages inputs from 5 to 24Vdc
Input frequency 50Hz/60Hz (±6%) +24Vdc user power supply (Max 180mA) regulated and short-circuit protected
User power supply
Input rectifier technology IGBT +10Vdc user power supply (Max 2 potentiometers R= 1 kΩ) regulated and short-circuit
Rectifier bridge switching Digital I/O board:
2.8kHz 5 Digital Inputs: Programmable inputs and active high (24Vdc). Optically isolated.
frequency
5 Digital Outputs: programmable multi-function relays.
Displacement power factor 1 (factory settings) I/O Extension board (optional)
Analogue I/O board:
(DPF = cos Φ ) 0.90 leading ... 0.90 lagging (adjustable)
2 Analogue Input: Programmable and differential input.
Power factor (PF= i1/irms · cos 2 Analogue Output: Programmable outputs in voltage / current.
≥ 0.98
φ) External power supply (optional) 24 V External Power Supply integrated
Momentary power loss > 2sec (depending on the load inertia) SD card Port for an external SD Card. Data Logging, events registration.
Second environment (Industrial): C3 Standard. COMMUNICATIONS USB port
EMC input filter First environment (Domestic): C2 (Optional), C1 consult with Power Electronics. Standard hardware RS485 port
Harmonics filter LCL Ethernet
Optical fiber
Current thd (%) < 3% / 5% [2] Optional hardware
Communication boards
Regenerative Yes – 4 quadrant operation Modbus-RTU
Standard protocol
OUTPUT Output frequency [3] 0... 599Hz Ethernet (Modbus TCP)
Constant torque/heavy duty: 150% during 60 sec at 50ºC Profibus-DP
Overload capacity Variable torque/normal duty: 120% during 60 sec at 40ºC. Optional protocol Ethernet IP
Efficiency (at full load) ≥97% ProfiNet
V/Hz CONTROL PANEL Type Removable
VECTOR CONTROL Length 3 meters (optional)
Control method Open Loop: PMC speed / torque control, AVC: speed / torque control Connection USB
Close Loop (Encoder): PMC speed / torque control, AVC: speed / torque control LED RUN: Motor receiving power supply
Visualization leds
PMSM I/f, Sensorless and HEPOL (High Efficiency Performance Open Loop) LED FAULT: Flashing displays that a fault has occurred
Carrier frequency 4 to 8kHz – PEWave LCD Screen
LCD display Keypad with 8 keys to control and configure the drive, start and stop/reset
Output dV/dt filter 500 - 800 V/µs [3]
Independent memory
Output cable length [4] USC 300m, SC 150m Average current and 3-phase motor current
Dynamic brake - Average voltage and 3-phase motor voltage
Average input voltage and 3-phase input voltage
ENVIRONMENTAL Minimum: -20°C; Maximum: +50°C (Heavy Duty) Display information
Operation ambient temperature 3-phase input and output frequency
CONDITIONS Minimum: -20°C; Maximum: +40°C (Normal Duty)
DC Bus Voltage
Storage temperature Minimum: -40°C; Maximum: +70°C Drive Status
Altitude 1000m Real time clock
Power altitude derating [1] >1000m, 1% PN (kW) per 100m; 4000m maximum (for higher altitude consult with PE) Perpetual calendar
Ambient humidity <95%, non-condensing Speed, Torque, Power, Power factor of motor
Degree of protection IP54 [5], IP42 [6], Marine series adapted (IP44/IP54, under request) Register of total and partial drive running time with reset function. (hours)
Amplitude: ± 1mm (2Hz-13.2Hz), ± 0.075mm (13.2Hz-57Hz) Register of total and partial drive energy consumption with reset function (kWh)
Vibration Acceleration: 6.86m/s² (13.2Hz-57Hz), 9.8m/s² (57Hz-150Hz) Relay status
Others Digital inputs / PTC status
Heating resistors Optional Output comparator status
Rotor locked, Motor overload (thermal model), Output current limit, Phase current imbalance, Analogue inputs and sensor values
PROTECTIONS Motor protections Phase voltage imbalance, Motor over-temperature (PT100 signal), Speed limit Torque limit. Analogue output value
IGBT’s overload, Input phase loss, Low input voltage, High input voltage, DC Bus voltage limit, Motor overload and equipment status
Low DC Bus voltage, High input frequency, Low input frequency, IGBT temperature, Heat- Drive and rectifier temperature
Drive protections sink over-temperature, Power supply fault, Drive thermal model, Ground fault, Software and Fault history (last 6 faults)
Hardware fault, Analogue input signal loss (speed reference loss), Safe stop/Emergency Stop REGULATIONS Certifications CE, cTick, UL[7], cUL[7], Marine certifications (under request)
EMC Directive (2004/108/CE)
Electromagnetic compatibility
IEC/EN 61800-3
LVD Directive (2006/95/CE)
IEC/EN 61800-2 General requirements
Design and construction IEC/EN 61800-5-1 Safety
IEC/EN 60146-1-1 Semiconductor converters
IEC60068-2-6 – Vibration
Functional safety IEC/EN 61800-5-2 Safety Stop (STO)
NOTES [1]: Consult with Power Electronics for other configurations. [4]: SC: Shielded cable, USC: Unshielded Cable. Follow Power Electronics installation
[2]: THDi < 3% (THDv = 0%). Harmonics are below the limits recommendations. For greater cable lengths, consult Power Electronics.
32 defined in IEEE519 for all Isc / IL.
[3]: For operation frequencies higher than 100Hz consult
[5]: Applicable to the electronics.
[6]: For stand-alone models.
33
Power Electronics. [7]: Certification in process.
POWER ELECTRONICS OUR PRODUCTS
6 SD75F0450 5BCD 250 350 450 220 300 370 555 SD75F2750 5BCD 1500 2200 2292 1200 1750 1833 2750
SD75F0570 5BCD 315 400 570 250 350 460 690 SD75F3100 5BCD 1750 2450 2583 1400 2000 2083 3125
SD75F0700 5BCD 400 550 700 315 450 580 870
7 SD75F0800 5BCD 450 650 800 355 500 650 975
SD75F0900 5BCD 500 700 900 400 550 720 1080 Operation temperature 40°C Operation temperature 50°C
SD75F1050 5BCD 560 800 1050 450 700 840 1260 NORMAL DUTY HEAVY DUTY OVERLOAD
FRAME CODE
8 SD75F1140 5BCD 630 900 1140 500 750 925 1388 Motor power Motor power I(A) Motor power Motor power I(A) (A)
SD75F1230 5BCD 710 940 1230 560 800 990 1485 (kW) (hp) Rated (kW) (hp) Rated
SD75F1400 5BCD 800 1000 1400 630 900 1150 1725 SD75F0160 6BCD 132 200 160 110 150 130 195
SD75F1550 5BCD 900 1250 1550 710 1000 1260 1890 5 SD75F0180 6BCD 160 250 180 132 200 150 225
SD75F1800 5BCD 1000 1400 1800 800 1150 1440 2160 SD75F0210 6BCD 200 300 210 160 250 170 255
>8 SD75F1950 5BCD 1100 1500 1950 900 1250 1580 2370 SD75F0250 6BCD 250 350 250 200 300 210 315
6 SD75F0450 5BCD 250 350 409 220 300 336 505 SD75F1850 6BCD 1800 2400 1850 1700 2200 1500 2250
SD75F0570 5BCD 315 400 518 250 350 418 627 SD75F2200 6BCD 2100 2750 2200 1800 2400 1800 2700
SD75F0700 5BCD 400 550 636 315 450 527 791 SD75F2500 6BCD 2200 3000 2500 2100 2750 2000 3000
7 SD75F0800 5BCD 450 650 727 355 500 591 886
SD75F0900 5BCD 500 700 818 400 550 655 982
SD75F1050 5BCD 560 800 955 450 700 764 1145
8 SD75F1140 5BCD 630 900 1036 500 750 841 1262
SD75F1230 5BCD 710 940 1118 560 800 900 1350
SD75F1400 5BCD 800 1000 1273 630 900 1045 1568
SD75F1550 5BCD 900 1250 1409 710 1000 1145 1718
SD75F1800 5BCD 1000 1400 1636 800 1150 1309 1964
>8 SD75F1950 5BCD 1100 1500 1773 900 1250 1436 2155
SD75F2250 5BCD 1200 1750 2045 1000 1450 1636 2455
SD75F2750 5BCD 1500 2200 2500 1200 1750 2000 3000
34 SD75F3100 5BCD 1750 2450 2818 1400 2000 2273 3409 35
POWER ELECTRONICS OUR PRODUCTS
W
FRAMES 5 TO 8
D
Frame 6
Frame 7
36 37
POWER ELECTRONICS OUR PRODUCTS
SD750K
Keeps the advanced family SD750K Series goes
one step ahead
features reducing up to 2.5 keeping the family
unique characteristics.
times the size.
1 Space Saving
When the space saving is the must, the SD750
Kompakt series with a power density up to
2200kW is your suitable solution.
2 IP00 and
IP20 option
Inspired by the contactors wiring concept, it has a
top input power and a bottom output motor cable.
The drive unit and the input chokes are delivered
together with a IP00 degree of protection.
38 39
POWER ELECTRONICS OUR PRODUCTS
HARDWARE Digital inputs 6 programmable, Active high (24Vdc), Isolated power supply
SD750K Digital outputs 3 programmable changeover relays (250Vac, 8A or 30Vdc, 8A)
3 programmable differential inputs. 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc, PT100.
Analogue input
110kW - 2200kW (Optically isolated)
INPUT Power range [1]
Analogue outputs One isolated programmable outputs: 0 – 20mA, 4 – 20mA, 0 – 10Vdc and ±10Vdc
Voltage range 380 - 480Vac ( 10%), 525 (-5/+10%), 600 - 690 (-5/+10%)
Encoder inputs (optional) Two differential encoders input. Voltages inputs from 5 to 24Vdc
Input frequency 50Hz/60Hz (±6%) +24Vdc user power supply (Max 180mA) regulated and short-circuit protected
Input rectifier technology Diode-Diode F1-F2/Thyristor-Diode F3-F11 (multipulse available [1]) User power supply +10Vdc user power supply (Max 2 potentiometers R= 1 kΩ) regulated and short-circuit
protected
Displacement power factor ≥ 0.98 Digital I/O board:
(DPF = cos Φ )
5 Digital Inputs: Programmable inputs and active high (24Vdc). Optically isolated.
Power factor
≥ 0.91 5 Digital Outputs: programmable multi-function relays.
(PF= i1/irms · cos φ) I/O Extension board (optional)
Analogue I/O board:
Momentary power loss > 2sec (depending on the load inertia) 2 Analogue Input: Programmable and differential input.
Second environment (Industrial): C3 Standard. 2 Analogue Output: Programmable outputs in voltage / current.
EMC input filter First environment (Domestic): C2 (Optional), C1 consult with Power Electronics. External power supply (optional) 24 V External Power Supply integrated
IT filter optional SD card Port for an external SD Card. Data Logging, events registration.
Harmonics filter LCL COMMUNICATIONS USB port
Current thd (%) <40% Standard hardware RS485 port
Ethernet
Regenerative No
Optical fiber
0... 599Hz Optional hardware Communication boards
OUTPUT Output frequency [2]
2 SD75K0450 5BCD 250 350 409 220 300 336 505 SD75K2500 7BCD 1800 2400 2500 1600 2100 2000 3000
SD75K0570 5BCD 315 400 518 250 350 418 627
SD75K0700 5BCD 400 550 636 315 450 527 791
3 SD75K0800 5BCD 450 650 727 355 500 591 886
SD75K0900 5BCD 500 700 818 400 550 655 982
SD75K1050 5BCD 560 800 955 450 700 764 1145
4 SD75K1140 5BCD 630 900 1036 500 750 841 1262
SD75K1230 5BCD 710 940 1118 560 800 900 1350
SD75K1400 5BCD 800 1000 1273 630 900 1045 1568
SD75K1550 5BCD 900 1250 1409 710 1000 1145 1718
SD75K1800 5BCD 1000 1400 1636 800 1150 1309 1964
>4 [1] SD75K1950 5BCD 1100 1500 1773 900 1250 1436 2155
42 SD75K2250 5BCD
SD75K2750 5BCD
1200
1500
1750
2200
2045
2500
1000
1200
1450
1750
1636
2000
2455
3000
NOTES [1] Consult availability with Power Electronics.
43
SD75K3100 5BCD 1750 2450 2818 1400 2000 2273 3409
POWER ELECTRONICS OUR PRODUCTS
2 SD75K0310 6BCD 250 350 310 220 300 260 390 2 525 400 1341 159
SD75K0400 6BCD 355 450 400 250 350 320 480 3 759 400 1343 215,3
SD75K0480 6BCD 400 550 480 355 450 385 578 4 1025 400 1343 299,7
3
SD75K0570 6BCD 500 650 570 400 550 460 690
SD75K0680 6BCD 560 800 680 500 650 550 825
4
SD75K0825 6BCD 710 950 825 560 800 660 990
SD75K0930 6BCD 800 1100 930 710 950 750 1125 FRAMES 1 TO 4
SD75K1050 6BCD 900 1250 1050 800 1100 840 1260 W D
SD75K1200 6BCD 1000 1400 1200 900 1250 950 1425
SD75K1400 6BCD 1200 1600 1400 1000 1400 1140 1710
>4 [1] SD75K1550 6BCD 1300 1700 1550 1200 1600 1270 1905 IP00
SD75K1750 6BCD 1500 2000 1750 1300 1700 1420 2130
SD75K1850 6BCD 1600 2200 1850 1500 2000 1500 2250
SD75K2200 6BCD 1900 2500 2200 1600 2200 1800 2700
SD75K2500 6BCD 2200 2900 2500 1900 2500 2000 3000
MECHANICAL ACCESSORIES
We take care
of the legacy generations
Each new generation of inverters involves adapting the manufacturing lines to optimize
the production of these new devices. Power Electronics has a facility optimized for the
production of limited units from previous generations, where we manufacture current
BY POWER ELECTRONICS subcomponents adapted to equipment that is no longer in production, but which allows
for an extended life.
HEM
48 49
POWER ELECTRONICS WARRANTY
We are here to
WARRANTY
help you
Power Electronics (the Seller) warrants that
Vertical
their Products are free of faults and defects for a
period of 3 years, valid from the date of delivery
to the Buyer. It shall be understood that a product
is free of faults and defects when its condition
Integration
and performance is in compliance with its
specification.
Scan me!
The warranty shall not extend to any Products
whose defects are due to (i) careless or
improper use, (ii) failure to observe the Seller’s
throughout the entire process instructions regarding the transport, installation,
functioning, maintenance and the storage of
We complement your spare parts strategy with our own thanks to our Dedicated Service the Products, (iii) repairs or modifications made
Factory warehouse, informing you when any of them is going to be discontinued so you by the Buyer or third party without prior written
can plan accordingly. authorization of the Seller, (iv) negligence during
the implementation of authorized repairs or
modifications, (v) if serial numbers are modified
or illegible, (vi) anomalies caused by, or connected
to, the elements coupled directly by the Buyer or
by the final customer, (vii) accidents or events
Before commissioning that place the Product outside its storage and
operational specification, viii) continued use of the
Products after identification of a fault or defect.
· Technical applications & design requirement review
· Dedicated Project Management Support The warranty excludes components that must be
· Hands on functional & safety product training replaced periodically such as Fuses + DC switch,
lamps & air filters or consumable materials
subject to normal wear and tear.
50 Power Electronics reserves the right to modify whole or part of the content of this
brochure at any time and without prior notice. May 2021. 51
POWER ELECTRONICS
HEADQUARTERS
SPAIN UNITED STATES
Polígono Pla de Carrases 1510 N. Hobson Street, Gilbert
CV-35 Exit 30, 46160 Arizona, USA
Lliria - Valencia - Spain Tel. (+001) 602-354-4890
Tel. (+34) 96 136 65 57 [email protected]
Fax (+34) 96 131 82 01 24/7 Technical Assistance Service
24/7 Technical Assistance Service Tel. (+001) 902 40 20 70
Tel. (+34) 902 40 20 70
INTERNATIONAL
ARGENTINA FRANCE PERU
Arroyo 894, 5º 51 Rue Hoche, 94200 Ivry Sur Seine. Avenida El Polo nº 670, Centro Comercial
Oficina 10 Ciudad autónoma de Paris (France) El Polo II – Oficina 603, Piso 6º, Bloque C
Buenos Aires +33(0)1 46 46 10 34 Santiago de Surco, Lima
[email protected] (+51) 979 749 772
ASIA Contact: Guillaume Mamy [email protected]
30th Floor, CATIC Plaza, 8 Cau- Contact: Gustavo Prialé
seway Road, Hong Kong SAR INDIA
Silver Jade, Off. No 03, G.F., A-Wing CTS NO. GERMANY
AUSTRALIA -188, Behind Tarun Bharat Society, Chakala, Neuseser Strasse 15, 90455
U6, 30-34 Octal St. Yatala, Brisbane, Andheri East, Mumbai, Maharashtra Nürnberg. Germany
Queensland 4118, Australia (+91) 80 6569 0489 [email protected]
(+61) 7 3386 1993 [email protected]
[email protected] SOUTH AFRICA
Central Office Park Unit 5
ITALIA
BEIJING Piazzale Cadorna, 6, 20123.
257 Jean Avenue – Centurion 0157
Xiaoying Road Chaoyang, Nº25, [email protected]
Milán Italia
Beijing City [email protected]
UNITED KINGDOM
BRAZIL JAPAN Chippenham Drive, Unit 2, Madingley Court.
Nishi-Shinbasi 2-17-2 HF Toranomon Bldg 5F. Kingston, Milton Keynes.
Avda. Robert Kennedy 2070. Sao Bernardo do
105-0003 Minato-Ku Tokio MK10 0BZ, United Kingdom
Campo. Sao Paulo
[email protected] [email protected]
(+55) 11 5891 9612 / (+55) 11 5891 9762
Contact: Stanley Han Contact (Solar division): Juan Antonio Torres
[email protected]
Contact: Fabio Cinquini
MALAYSIA PHILIPPINES
Unit 209 ZF Page 1 Bldg MBP
CHILE Level 7, Menara Milenium, Jalan Damanlela,
Pusat Bandar Damansara, Damansara Ayala Alabang, Muntinlupa.
Av. Alonso de Córdova 5870, Of. 210-211
Heigths, 50490 Kuala Lumpur W.P.
Las Condes, Santiago de Chile
(+56) 2 3223 8916
Malaysia REPÚBLICA DOMINICANA
[email protected] Ave. John F. Kennedy Núm. 7, Los Jardines,
[email protected]
Distrito Nacional, República Dominicana.
COLOMBIA MEXICO
Henry Ford n.3, Fraccionamiento Industrial IRELAND
Cl 77 9-20 Bogotá DC 20 Harcourt Street Dublin,
San Nicolás, Tlalnepantla, Estado de México
Colombia D02 H364, Irlanda
(+52) 1 55 4949 0830 / (+52) 539 08818
(+57) 322 3464855
[email protected]
[email protected]
Contact: Manuel Garay
Contact: Héctor Nuñez
March 2022