0% found this document useful (0 votes)
238 views8 pages

PC160 Merik Home Access Home Depot

The document provides instructions for setting up and using a PC160 control box for an automatic gate system. It includes: 1) Installing the control box and connecting the various system components like motors, lights, sensors. 2) Adjusting dip switches and potentiometers to configure settings for features like auto-close timing, speed control, and sensor response. 3) A process for memorizing remote controls and learning the gate's movement sequence automatically. 4) Descriptions of indicator lights and buttons on the control box for operation and troubleshooting.

Uploaded by

Isaac Santoy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
238 views8 pages

PC160 Merik Home Access Home Depot

The document provides instructions for setting up and using a PC160 control box for an automatic gate system. It includes: 1) Installing the control box and connecting the various system components like motors, lights, sensors. 2) Adjusting dip switches and potentiometers to configure settings for features like auto-close timing, speed control, and sensor response. 3) A process for memorizing remote controls and learning the gate's movement sequence automatically. 4) Descriptions of indicator lights and buttons on the control box for operation and troubleshooting.

Uploaded by

Isaac Santoy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

PC160 Control Box

24V DC GEAR MOTOR

FOR RESIDENTIAL
USER MANUAL
Index

1. PC160 Control Box 2


2. Setting 4
2.1 SW1 Dip Switch Setting 4
2.2 Functional Switch and LED lights Introduction 5
2.3 Transmitter Memorizing and Erasing Process 5
2.4 System Learning Process 5
2.5 Gate Operation 6
2.6 Gate-moving Logic 6
3. Trouble Shooting 6
4. Technical Characteristics 6
4.1 PC160 Control Box 6
5. CE Declaration of Conformity 7

1 CONTROL BOX
1). PC160 Control Box

1. Decide the installation position of PC160 control box first, it is suggested to be installed near the gate and should
be protected from possible damage. Be aware of the motor cable length before deciding the installation position.
2. Remove the cover by unscrewing the four screws on the cover. See Figure 1(1).
3. Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure 1(2).
4. Secure it on the wall. See Figure 1(3).
Figure 1(1) Figure 1(2)

Figure 1(3)

5. Wiring Connection:
Prepare all the wires of the accessories beforehand and connect the wires to the gear motors and accessories on
the PCB as shown in Figure 1(4). All of the wiring connections of the accessories are not requested to
distinguish the positive (+) and the negative (-) polarity.
1). PF-1 Flashing light: Connect the two wires from the flashing light to the terminal LIGHT and GND on the PCB.
2). PEL-1 Electric Latch: Connect the two wires from the electric latch to the terminal LATCH and GND on the PCB.
3). PW150/PW200 Gear Motors:
Refer to Figure 1(5) and connect the wires separately to the terminals on the PCB.
M1: Connect the motor wire (White +) to the terminals M1 (+), and (Yellow -) to the M1 (-).
M2: Connect the motor wire (White +) to the terminals M2 (+), and (Yellow -) to the M2 (-).

Notes:
For gates opened outward,
M1: Connect the motor wire (Yellow -) to the terminals M1 (+), and (White +) to the terminals M1 (-).
M2: Connect the motor wire (Yellow -) to the terminals M2 (+), and (White +) to the terminals M2 (-).

4). PH-1 Photocells: Please remove the cover of JP1 and connect the wires to proper terminals.

5). PKS-1 Key Selector:


For Single leaf operation-Refer to Figure 1(4) and connect the two wires from the key selector to the terminal
BUTT1 and GND (J7) on the PCB.
For Dual leaf operation-Refer to Figure 1(4) and connect the two wires from the key selector to the terminal
BUTT2 and GND (J7) on the PCB.

6). PPB-1 Push Button:


For Single leaf operation-Refer to Figure 1(4) and connect the two wires from the key selector to the terminal
BUTT1 and GND (J7) on the PCB.
For Dual leaf operation-Refer to Figure 1(4) and connect the two wires from the key selector to the terminal
BUTT2 and GND (J7) on the PCB.

7). JP2 Jumper Socket: If there is any external device connecting to stop/GND/close/open terminals on the PCBA,
please remove JP2 cover to make the device effective.

CONTROL BOX 2
Figure 1(4)
PW150/200 Manual

J2
J1
LIGHT DELAY OFF ON
OPENING PHOTO OFF ON
SLOW DOWN SPEED OFF ON

AUTO CLOSE1 OFF ON

AUTO CLOSE2 OFF ON

JP2 JP1 Red Yellow Green

M1

M2

3 CONTROL BOX
Figure 1(5)

M1

2). Setting

2.1 SW1 Dip Switch Setting


DIP SWITCH1 LIGHT DELAY: (Factory Default: OFF)
ON: The flashing light blinks for 5 seconds before the gate moves.
ON OFF
OFF: The flashing light blinks and the gate moves simultaneously.
LIGHT DELAY

OPENING PHOTO: (Factory Default: OFF)


DIP SWITCH2
ON: In the opening phase, the gate will stop when the photo sensor is activated.
ON OFF
In the closing phase, the gate will stop and open to the end when the photo
OPENING PHOTO sensor is activated.
OFF: In the opening phase, the gate will not stop when the photo sensor is activated.
In the closing phase, the gate will stop and open to the end when the photo
sensor is activated.

DIP SWITCH3 SLOW DOWN SPEED: (Factory Default: ON)


The final speed can be set when the gate is moving at slow-down speed.
ON OFF
ON: The final speed = 55% normal speed.
SLOW DOWN SPEED OFF: The final speed = 70% normal speed.

DIP SWITCH4
AUTO CLOSE1: (Factory Default: OFF)
The function of auto close or without auto close can be selected.
ON OFF

AUTO CLOSE1

DIP SWITCH5 AUTO CLOSE2: (Factory Default: OFF)


ON OFF
The function of auto close or without auto close can be selected.

AUTO CLOSE2

DIP4 (Auto close1) DIP5 (Auto close2) Function


OFF OFF Without auto close function
OFF ON Auto close On, waiting time 50 seconds
ON OFF Auto close On, waiting time 25 seconds
ON ON Auto close On, waiting time 12 seconds

NC: No Connection

CONTROL BOX 4
2.2 Functional Switch and LED lights Introduction
SW2 The button of transmitter memorizing and erasing.
VR1 Close delay of two leaves can be adjusted from min 0 second to Max. 7 second.
VR2 The over-current sensitivity of Master Gate (M1) could be adjusted from 1.8 second to 3.8 second.
VR3 The over-current sensitivity of Master Gate (M2) could be adjusted from 1.8 second to 3.8 second.
VR4 Over-current limit can be adjusted from min 0.8Amp to Max 4.2 Amp.
LED1 (Red) LED1 is ON when AC input is in. And LED1 blinks quickly when the gate is in slow-down speed.
LED2 (Yellow) When the photocells are triggered, LED2 will be on.
LED3 (Green) When the transmitter/push button/key selector is triggered, LED3 will be on.
Notes:
1. VR1,VR2,VR3 will be adjusted to 10 o’clock direction as the factory default.
2. VR4 will be adjusted to 2 o’clock direction as the factory default.

2.3 Transmitter Memorizing and Erasing Process


RF Transmitter Memorizing & Erasing
2.3.1 Press button SW2 for 1 second, the blue LED light on the receiver board will be on and receiver module
will be changed to “Learning Mode” for 10 seconds. During the period of learning mode, press the left
button on the transmitter, then the transmitter can be memorized by receiver module. (Up to 200 different
transmitter can be memorized) The blue light on the receiver board will blink twice after pressing the
button on the transmitter. The blue light on the receiver board will go off when the transmitter memorizing
is done.

2.3.2 The memory can be cleared completely if the SW2 (code learning) is pressed continuously for 10 seconds
after the blue light.

Self-Learning mode for gate operation systems


Step1: Connect the wires of two motors with terminal M1+/M1- & M2+/M2-
Step2: Connect 230VAC with terminal J1 and battery with J2.
Setp3: In single leaf installation, just connect the motor wires with terminal M1+/M1-
Step4: Press SW2 button for more than 1 second and the blue light on the receiver board is on. Press the left button
on the transmitter to memorize the transmitter with the receiver board. The blue light will be off after the
transmitter memorizing is done.
Step5: In Single or Dual leaf installation, please press the left button of the remote control for system learning. After
pressing the left button, system learning will be executed step by step as follows:
1. Dual Gate:
Slave Gate Close → Master Gate Close → Master Gate Open → Slave Gate Open → Slave Gate Close
→ Master Gate Close
2. Single Mode :
Master Gate Close → Master Gate Open → Master Gate Close
Step 6: If motor stops during the learning mode, please adjust the over current switch to proper position.

2.4 System Learning Process


Connect the master motor wires to M1 terminals and the slave motor wires to M2 terminals correctly. If only one
gate is installed, the motor wires have to be connected to M1 terminals.
In system learning mode, the gates will proceed with the following procedures.

(A) Dual-Gate Mode: Slave Gate closes→ Master Gate closes→ Master Gate opens →Slave Gate opens →
Slave Gate closes→ Master Gate closes.
(B) Single-Gate Mode: Master Gate closes→ Master Gate opens→ Master Gate closes.

Notes: System learning fails and needs to be learned again when an unpredictable interruption occurs.

5 CONTROL BOX
2.5 Gate Operation
In dual gate installation: A B
Press the button “A” on the transmitter for dual-gate operation.
Press the button “B” on the transmitter for single-gate operation.
In single gate installation:
Press the button “A” on the transmitter for single-gate operation.
PR-1

2.6 Gate-moving Logic


(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when
the transmitter/push button/key selector is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when
the transmitter/push button/key selector is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.

3. Trouble Shooting

Symptoms Recommended checks and possible solution


Overheated Back-up Batteries Check the wiring connection of the batteries.
The gate doesn’t move when pressing the 1. Check if the voltage of the batteries is below 21V.
button of the transmitter 2. Check if LED1 is “ON”.
3. Make sure all the wiring connections are firmly connected to the
terminals on the PCB.
4. Make sure the fuse is workable.
The Flashing light does not work 1. Check if the wiring connection of the flashing light is correct.
2. Check if the bulb is burned.
The leaves shall be closed instead of opening Change the polarity connection of the positive (+) with the negative (-)
of the gear motors.
The leaves does not move or only move toward 1. Check if the “RESET” socket is activated.
one direction 2. Make sure the wiring connection of the gear motors is firm.
3. The GND terminal of the photocells on the PCB must be
short-circuited if no photocells installed.
The master gate closes to the end first and the Cut off the AC input power and the output of the batteries. Release the
slave gate stops, the flashing light blinks fast for master gate and slave gate manually, then open the master to the end
five seconds. and close the slave gate to the end by hand, then power the whole
unit by connecting the AC and battery terminals.
The gear motors does not run and the relay is
noisy when operating the gate opening and Check if the fuse is burned.
closing.

CONTROL BOX 6
Declaration of Conformity

Applicant: Powertech Electronics Inc.


Manufacturer: Timotion Technology Co., Ltd.
Address: Shiyong Minying Industrial Zone, Hengli Town, DongGuan City, GuangDong, China

Model: PC160

1. Certificate of conformity of a product with the essential requirements art. 3.2 of the R&TTE Directive 1999/5/EC.
2. The above product has been tested with the listed standards and in compliance with the European Directive LVD
2006/95/EC.
3. The submitted sample of the above product has been tasted for CE marking according to the following European Directives:
2006/42/EC Machinery Directive.

Comply with the following Standards:

EN 301489-1 V1.8.1: 2008


EN 301489-3 V1.4.1: 2002
EN 300220-1 V2.1.1: 2006
EN 300220-2 V2.1.2: 2007

EN 60335-1: 2002+A11:2004+A1:2004+A12:2006+A2:2006+A13:2008
EN 60335-2-103: 2003
EN 62233: 2008

EN 12445: 2001
EN 12453: 2001

And also declare that the machinery may not be put into service until the machine, which will be integrated or become one of
the components, and announced to comply with the provisions as the required.

Taiwan, May 18, 2012 David Lan

(Deputy Managing Director)

7 CONTROL BOX

You might also like