PC160 Merik Home Access Home Depot
PC160 Merik Home Access Home Depot
FOR RESIDENTIAL
USER MANUAL
Index
1 CONTROL BOX
1). PC160 Control Box
1. Decide the installation position of PC160 control box first, it is suggested to be installed near the gate and should
be protected from possible damage. Be aware of the motor cable length before deciding the installation position.
2. Remove the cover by unscrewing the four screws on the cover. See Figure 1(1).
3. Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure 1(2).
4. Secure it on the wall. See Figure 1(3).
Figure 1(1) Figure 1(2)
Figure 1(3)
5. Wiring Connection:
Prepare all the wires of the accessories beforehand and connect the wires to the gear motors and accessories on
the PCB as shown in Figure 1(4). All of the wiring connections of the accessories are not requested to
distinguish the positive (+) and the negative (-) polarity.
1). PF-1 Flashing light: Connect the two wires from the flashing light to the terminal LIGHT and GND on the PCB.
2). PEL-1 Electric Latch: Connect the two wires from the electric latch to the terminal LATCH and GND on the PCB.
3). PW150/PW200 Gear Motors:
Refer to Figure 1(5) and connect the wires separately to the terminals on the PCB.
M1: Connect the motor wire (White +) to the terminals M1 (+), and (Yellow -) to the M1 (-).
M2: Connect the motor wire (White +) to the terminals M2 (+), and (Yellow -) to the M2 (-).
Notes:
For gates opened outward,
M1: Connect the motor wire (Yellow -) to the terminals M1 (+), and (White +) to the terminals M1 (-).
M2: Connect the motor wire (Yellow -) to the terminals M2 (+), and (White +) to the terminals M2 (-).
4). PH-1 Photocells: Please remove the cover of JP1 and connect the wires to proper terminals.
7). JP2 Jumper Socket: If there is any external device connecting to stop/GND/close/open terminals on the PCBA,
please remove JP2 cover to make the device effective.
CONTROL BOX 2
Figure 1(4)
PW150/200 Manual
J2
J1
LIGHT DELAY OFF ON
OPENING PHOTO OFF ON
SLOW DOWN SPEED OFF ON
M1
M2
3 CONTROL BOX
Figure 1(5)
M1
2). Setting
DIP SWITCH4
AUTO CLOSE1: (Factory Default: OFF)
The function of auto close or without auto close can be selected.
ON OFF
AUTO CLOSE1
AUTO CLOSE2
NC: No Connection
CONTROL BOX 4
2.2 Functional Switch and LED lights Introduction
SW2 The button of transmitter memorizing and erasing.
VR1 Close delay of two leaves can be adjusted from min 0 second to Max. 7 second.
VR2 The over-current sensitivity of Master Gate (M1) could be adjusted from 1.8 second to 3.8 second.
VR3 The over-current sensitivity of Master Gate (M2) could be adjusted from 1.8 second to 3.8 second.
VR4 Over-current limit can be adjusted from min 0.8Amp to Max 4.2 Amp.
LED1 (Red) LED1 is ON when AC input is in. And LED1 blinks quickly when the gate is in slow-down speed.
LED2 (Yellow) When the photocells are triggered, LED2 will be on.
LED3 (Green) When the transmitter/push button/key selector is triggered, LED3 will be on.
Notes:
1. VR1,VR2,VR3 will be adjusted to 10 o’clock direction as the factory default.
2. VR4 will be adjusted to 2 o’clock direction as the factory default.
2.3.2 The memory can be cleared completely if the SW2 (code learning) is pressed continuously for 10 seconds
after the blue light.
(A) Dual-Gate Mode: Slave Gate closes→ Master Gate closes→ Master Gate opens →Slave Gate opens →
Slave Gate closes→ Master Gate closes.
(B) Single-Gate Mode: Master Gate closes→ Master Gate opens→ Master Gate closes.
Notes: System learning fails and needs to be learned again when an unpredictable interruption occurs.
5 CONTROL BOX
2.5 Gate Operation
In dual gate installation: A B
Press the button “A” on the transmitter for dual-gate operation.
Press the button “B” on the transmitter for single-gate operation.
In single gate installation:
Press the button “A” on the transmitter for single-gate operation.
PR-1
3. Trouble Shooting
CONTROL BOX 6
Declaration of Conformity
Model: PC160
1. Certificate of conformity of a product with the essential requirements art. 3.2 of the R&TTE Directive 1999/5/EC.
2. The above product has been tested with the listed standards and in compliance with the European Directive LVD
2006/95/EC.
3. The submitted sample of the above product has been tasted for CE marking according to the following European Directives:
2006/42/EC Machinery Directive.
EN 60335-1: 2002+A11:2004+A1:2004+A12:2006+A2:2006+A13:2008
EN 60335-2-103: 2003
EN 62233: 2008
EN 12445: 2001
EN 12453: 2001
And also declare that the machinery may not be put into service until the machine, which will be integrated or become one of
the components, and announced to comply with the provisions as the required.
7 CONTROL BOX