Blue-White Rotameter Flowmeter f-440 Spec
Blue-White Rotameter Flowmeter f-440 Spec
F-440
Compact Size
Rod Guided Float
Specifications: Dimensions:
o o
Max. working pressure: ........175 PSI (10.3 bar) @ 70 F (21 C) B B
B
Max. fluid temperature: C C
Standard units......................212o F (100o C) @ 0 PSI
Solarmeterq units .................240o F (115o C) @ 0 PSI
Full scale accuracy: ..............+/- 4%
Calibration fluid: ...................Water, specific gravity 1.0 A
A A
Scale length: .........................2” (50mm) approx. D
D
F-44500
So F-44560
190°F/87.7°C
lar 7-1/2” 2” N/A N/A
me F-44750 191mm 51mm
170°F/76.6°C ter q F-44250E
Sta un
150°F/65.6°C nd its
F-44330E
7” 3” 1-11/16” 5-15/16”
ard F-44375E
178mm 76mm 43mm 151mm
un F-44376E
130°F/54.4°C its F-44500E
Elbow
7” 3” 2” 6-13/16”
F-44560E 178mm 76mm 51mm 173mm
110°F/43.3°C
8-1/8” 3” 2” 6-13/16”
F-44750E 206mm 76mm 51mm 173mm
90°F/32.2°C F-44250EA
F-44330EA
Adjustable
30 psi
2.1 bar
60 psi
4.1bar
90 psi
6.2 bar
120 psi
8.3 bar
150 psi
10.3 bar
175 psi
12 bar
F-44500EA
F-44560EA
8” 4-1/2” 2” 6-13/16”
F-44750EA 203mm 114mm 51mm 173mm
Blue-White Industries, Ltd.
Variable Area Flow Meters
Installation Requirements:
1. Misalignment will damage the meter! Ceiling
Flowmeter must be installed in an exact vertical plane to ensure accuracy. Be certain of proper plumbing
alignments. Misalignment may cause the o-ring seals to leak. The meterbody material can be damaged by UV
rays. Do not install in direct sunlight.
2. Pipe dope and glue will damage the meter! 3
Use only PTFE tape on the threaded adapters. The meter body and plastic fittings cannot tolerate PVC Glue
and/or pipe dope. Even fumes can cause severe damage. If you are installing your flowmeter to a glued pipe
configuration, install the flowmeter after all glued fittings are dried and lines are purged of all fumes. Never hold
the meter body with pliers or like tools. Union nuts should be hand tightened only. DO NOT OVER-TIGHTEN! 1 2
3. Vibration and heavy loads will damage the meter!
Wall, floor and ceiling mounts and supports must be carefully aligned with the meter body and sturdy enough to
support the plumbing and prevent vibration. Never allow the flowmeter to support the weight of related piping.
1) Liquid models calibrated with water, Sp.Gr. 1.0. Custom Sp.Gr. calibrations available. Contact the factory.