HS-2data Sheet
HS-2data Sheet
Megaplex-2100/2104 Module
HS-2
2-Channel High Speed Data Module
The HS-2 module features two high speed Any channel can be independently
synchronous data channels. Each channel configured for DCE, External-DCE
is independently set by the user for either or DTE timing modes. The External-DCE
V.35 or V.11/RS-422 interface (electrical). mode is used for tail-end applications: it
The V.11/RS-422 selection is used for provides Rx clock, while receiving Tx clock
RS-530, V.36/RS-449, or X.21 interface from the user equipment.
(physical) operation. Each high speed data channel terminates
Each channel operates at data rates of on a separate DB-25 connector. Pin
n x 64 or n x 56 kbps, where n = 1 to 31 assignment is compatible with RS-530
for E1 links, and 1 to 24 for T1 links. Total specifications. Special adapter cables are
combined bandwidth for both channels is used to connect each HS-2 channel to
up to 1,984 kbps for E1 links or standard V.35, V.36/RS-449, or X.21
1,536 kbps for T1 links. equipment (see Ordering). The adapter
Each channel of the local module may be cables are wired according to the required
directed to any channel of another HS clock mode.
module at the remote site. The timeslots
used on the T1 or E1 links are assigned by
the user.
product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
764-125-08/08 Specifications are subject to change without prior notice. © 1989–2008 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the
Local support of CTS, RTS, DCD and Clock Modes
DSR control signals for each channel is DCE: HS-2 channel provides both RX and
Ordering
provided. TX clocks to the user DTE MP-2100M-HS-2
Extensive diagnostics, including local and External DCE (DTE1, used for tail-end
applications): HS-2 channel provides RX OPTIONAL ACCESSORIES
remote channel loopbacks, as well as an
integral BER test, reduce downtime to a clock to the user while receiving TX clock CBL-HS2/*/#
minimum. from the user Adapter cable connecting the HS-2’s
DTE (DTE2): HS-2 channel receives both DB-25 channel connectors to the specified
Channel data rates and all other operating RX and TX clocks from the user DCE equipment (separate cable is needed for
parameters of HS-2 are soft-selectable
Control Signals each connector). The cable must be
through the Megaplex management
CTS follows RTS or is constantly ON, soft- chosen to match the desired clock mode.
system.
selectable Cable length is 2m (6ft)
DCD constantly ON, unless in RED ALARM Legend
Specifications (one DCD signal for all four channels) * Interface type:
DSR constantly ON when channel is V1 V.35, 34-pin, DCE
Number of Data Channels connected, unless engaged in test V2 V.35, 34-pin, Ext-DCE
2 V3 V.35, 34-pin, DTE
Diagnostics (per channel)
Data Rate per Channel R1 V.36/RS-499, 37-pin, DCE
Local loopback
Synchronous, R2 V.36/RS-499, 37-pin, Ext.DCE
Remote loopback
n × 64 or n × 56 kbps, where: R3 V.36/RS-499, 37-pin, DTE
Internal BERT (different patterns available)
for E1: n=1 to 31 X1 X.21, 15-pin, DCE
for T1: n=1 to 24 Configuration X2 X.21, 15-pin, Ext. DCE
Programmable via the Megaplex
Interface (Electrical) management system # Cable connector type:
User-selectable for each channel: V.35 or F female
V.11/RS-422 M male
Interface (Physical)
V.35, V.36/RS-449, or X.21 (via conversion
cables)
Connectors
Two DB-25, female (one for each channel)
Megaplex High Speed Modules