0% found this document useful (0 votes)
68 views

SE DS Fronius IG Plus Advanced US EN

Uploaded by

Andreas E
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views

SE DS Fronius IG Plus Advanced US EN

Uploaded by

Andreas E
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

/ Perfect Welding / Solar Energy / Perfect Charging

FRONIUS IG PLUS ADVANCED WITH


INTEGRATED AFCI

/ MIX Technology / Smart Transformer / Arc Fault Circuit / Quick Service / Smart Grid / Wi-Fi®* Interface
Switching Interruption Technology Ready

/ The Fronius IG Plus Advanced was the first complete inverter lineup of NEC 2011 compliant, AFCI protected,
inverters in the United States and continues to be the leader in quality inverter technology. Power classes ranging
from 3 to 12 kW in both single and true 3 phase applications with integrated Fronius MIX Technology and wide
voltage windows are the perfect match for your system design.

TECHNICAL DATA: FRONIUS IG PLUS ADVANCED


INPUT DATA 3.0-1UNI 3.8-1UNI 5.0-1UNI 6.0-1UNI 7.5-1UNI 10.0-1UNI 10.0-3DELTA 11.4-1UNI 11.4-3DELTA 12.0-3WYE277
Recommended PV-Power (kWp) 2.50 - 3.45 3.20 - 4.40 4.25 - 5.75 5.10 - 6.90 6.35 - 8.60 8.50 - 11.50 8.50 - 11.50 9.70 - 13.10 9.70 - 13.10 10.20 - 13.80
Nominal Input Current 8.3 A 10.5 A 13.8 A 16.5 A 20.7 A 27.6 A 27.6 A 31.4 A 31.4 A 33.1 A
Max. Usable Input Current 14.0 A 17.8 A 23.4 A 28.1 A 35.1 A 46.7 A 46.7 A 53.3 A 53.3 A 56.1 A
MPPT - Voltage Range 230 - 500 V
DC Startup 260 V
Max. Input Voltage 600 V
Admissable Conductor Size (DC) No. 14 to 6 AWG. For larger wire, use Fronius connecting distributor.
Max. Current per DC Input Terminal 20 Amps. For higher input current, use Fronius connecting distributor.

OUTPUT DATA 3.0-1UNI 3.8-1UNI 5.0-1UNI 6.0-1UNI 7.5-1UNI 10.0-1UNI 10.0-3DELTA 11.4-1UNI 11.4-3DELTA 12.0-3WYE277
Nominal Output Power 3,000 W 3,800 W 5,000 W 6,000 W 7,500 W 9,995 W 9,995 W 11,400 W 11,400 W 12,000 W
Max. Continuous Output Power 3,000 W 3,800 W 5,000 W 6,000 W 7,500 W 9,995 W 9,995 W 11,400 W 11,400 W 12,000 W
AC Output Voltage 208/240/277 208/240 208/240/277 208/240 480/277 WYE
Number of Phases 1 3 1 3
Admissible Conductor Size (AC) No. 14 - 4 AWG
Max. Continuous Utility Backfeed Current 0A
Nominal Output Frequency 60 Hz
Operating Frequency Range 59.3 - 60.5 Hz
Total Harmonic Distortion < 3 %
Power Factor 0.85 – 1 ind. / cap.
Operating AC Voltage Range 208 V 183 - 229 V (-12 / +10 %)
240 V 211 - 269 V (-12 / +10 %)
277 V 244 - 305 V (-12 / +10%)
Max. Continuous Output Current 208 V 14.4 A 18.3 A 24.0 A 28.8 A 36.1 A 48.1 A 27.7 A* 54.8 A 31.6 A* n.a.
240 V 12.5 A 15.8 A 20.8 A 25.0 A 31.3 A 41.7 A 24.0 A* 47.5 A 27.4 A* n.a.
277 V 10.8 A 13.7 A 18.1 A 21.7 A 27.1 A 36.1 A n.a. 41.2 A n.a. 14.4 A*
*Pre phase
*The term Wi-Fi® is a registered trademark of the Wi-Fi Alliance.
TECHNICAL DATA: FRONIUS IG PLUS ADVANCED

GENERAL DATA 3.0-1UNI 3.8-1UNI 5.0-1UNI 6.0-1UNI 7.5-1UNI 10.0-1UNI 10.0-3DELTA 11.4-1UNI 11.4-3DELTA 12.0-3WYE277
Max. Efficiency 96.2%
Unit Dimensions (W x H x D) 17.1 x 24.8 x 9.6 in. 17.1 x 36.4 x 9.6 in. 17.1 x 48.1 x 9.6 in.
CEC Efficiency 208 V 95.0 % 95.0 % 95.5 % 95.5 % 95.0 % 95.0 % 95.5 % 95.5 % 95.0 % n.a.
240 V 95.5 % 95.5 % 95.5 % 96.0 % 95.5 % 95.5 % 95.5 % 96.0 % 96.0 % n.a.
277 V 95.5 % 95.5 % 96.0 % 96.0 % 96.0 % 96.0 % n.a. 96.0 % n.a. 96.0 %
Consumption in Standby (Night) < 1.5 W
Consumption During Operation 8W 15 W 20 W
Cooling Controlled forced ventilation, variable speed fan
Enclosure Type NEMA 3R
Power Stack Weight 31 lbs. (14 kg) 57 lbs. (26 kg) 84 lbs. (38 kg)
Wiring Compartment Weight 24 lbs. (11 kg) 26 lbs. (12 kg)
Admissable Ambient Operating Temperature -40o F...+131o F (-40o C...+55o C)
Advanced Grid Features Active and reactive power control, low voltage ride-through
UL 1741-2010, IEEE 1547-2003, IEEE 1547.1, UL 1699B-2013, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No.
Compliance 107.1-01 (Sept. 2011) California Solar Initiative - Program Handbook - Appendix C: Inverter Integral 5% Meter Performance Specifica-
tion

PROTECTIVE EQUIPMENT 3.0-1UNI 3.8-1UNI 5.0-1UNI 6.0-1UNI 7.5-1UNI 10.0-1UNI 10.0-3DELTA 11.4-1UNI 11.4-3DELTA 12.0-3WYE277
Ground Fault Protection Internal GFDI (Ground Fault Detector/Interrupter) in accordance with UL 1741-2010 and NEC Art. 690
DC Reverse Polarity Protection Internal Diode
Islanding Protection Internal; in accordance with UL 1741-2010, IEEE 1547-2003 and NEC
Over Temperature Protection Output power derating / active cooling
Internal AFCI (Arc-Fault Circuit Interrupter); in accordance with UL 1699 Outline of Investigation for Photovoltaic (PV) DC Arc-Fault
Arc-Fault Circuit Protection

All information is without guarantee in spite of careful editing - liability excluded. Copyright © 2011 Fronius™. All rights reserved.
Circuit Protection (Issue Number 2, January 14, 2013)

/ Perfect Welding / Solar Energy / Perfect Charging Text and images correspond to the current state of technology at the time of printing. Subject to modifications.

WE HAVE THREE DIVISIONS AND ONE PASSION: SHIFTING THE LIMITS OF POSSIBILITY.
/ Whether welding technology, photovoltaics or battery charging technology − our goal is clearly defined: to be the innovation leader. With around
3,000 employees worldwide, we shift the limits of what’s possible - our more than 850 active patents are testimony to this. While others progress
step by step, we innovate in leaps and bounds. Just as we’ve always done. The responsible use of our resources forms the basis of our corporate policy.

Further information about all Fronius products and our global sales partners and representatives can be found at www.fronius.com

v02 Feb 2014 EN

Fronius USA LLC


6797 Fronius Drive
Portage, IN 46368
USA
[email protected]
www.fronius-usa.com