NCP 109.3 Code of Practice Access Control Systems June 2021
NCP 109.3 Code of Practice Access Control Systems June 2021
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 1 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Contents
1 Scope ...................................................................................................................................................................... 4
2 References ............................................................................................................................................................ 5
3 Terms, definitions and abbreviations ......................................................................................................... 5
3.1 Terms and definitions.............................................................................................................................. 5
3.2 Abbreviations ............................................................................................................................................. 9
4 Classification of access points ..................................................................................................................... 10
4.1 General........................................................................................................................................................ 10
4.2 Risk assessment ....................................................................................................................................... 10
4.3 Access point classification ................................................................................................................... 11
5 Design .................................................................................................................................................................. 14
5.1 Survey .......................................................................................................................................................... 14
5.2 Credentials ................................................................................................................................................. 16
5.3 Functionality ............................................................................................................................................. 17
6 Equipment selection and installation ....................................................................................................... 22
6.1 Control ........................................................................................................................................................ 22
6.2 Access point hardware .......................................................................................................................... 22
6.3 Environmental protection .................................................................................................................... 24
6.4 Power supplies ......................................................................................................................................... 24
7 Installation .......................................................................................................................................................... 26
7.1 Cables .......................................................................................................................................................... 26
7.2 Network security ..................................................................................................................................... 28
8 Commissioning, handover and documentation ................................................................................... 29
8.2 Handover ................................................................................................................................................... 30
8.3 Documentation ........................................................................................................................................ 31
9 Maintenance ...................................................................................................................................................... 32
9.1 Resources ................................................................................................................................................... 32
9.2 Preventive maintenance ....................................................................................................................... 33
9.3 Corrective maintenance........................................................................................................................ 34
9.4 Records ....................................................................................................................................................... 34
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 2 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Introduction
This Code of Practice is to be read in conjunction with the NSI Regulations relating to
approval by NSI, to the NACOSS Gold and the Systems Silver approval criteria.
No company shall hold out or claim that it adheres to this Code, save by virtue of
holding NSI approval, or having obtained the written permission of NSI.`
An Access Control System (ACS) consists of credential recognition equipment and user
interface(s) such as a token and reader (e.g. Card, token reader, keypad, biometrics etc.),
electronically activated entrance release hardware and, in certain systems, means for central
control and/or monitoring.
The objectives of this Code of Practice are to:
• establish and maintain minimum standards of best practice for the design, installation,
commissioning, handover and maintenance for ACS(s);
• provide a framework to assist purchasers, installers and users in establishing their
requirements with suppliers;
• assist specifiers and users in determining the appropriate level of security required for a
given application; and
• assist system designers in meeting specifier or user requirements.
The successful operation of an ACS requires the active co-operation of the user in carrying out
the necessary procedures carefully and thoroughly. The usefulness of the whole system and its
security and social acceptability can be jeopardised by lack of care. This care has to extend to
the security of credentials, such as tokens and of information regarding the system, its design,
installation and method of operation and to ensuring adequate maintenance, to preserve the
security of access.
Your attention is drawn to:
• the Equality Act 2010, which aims to protect disabled people and to prevent disability
discrimination, and the Disability Discrimination Act 2005 (as amended), the Disability
Equality Duty of which continues to apply;
• relevant national building regulations;
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 3 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
• BS 7273-4 – Code of practice for the operation of fire protection measures. Part 4.
Actuation of release mechanisms for doors;
• BS 7671, Requirements for Electrical Installations (also known as the “I.E.T Wiring
Regulations”); and
• Loss Prevention Standard LPS 1175, Requirements and testing procedures for the LPCB
approval and listing of intruder resistant building components, strongpoints, security
enclosures and free-standing barriers.
Note: The BS EN 50133 series of standards have been withdrawn and replaced with the
BS EN 60839-11 series of standards. At the time of publishing this document, the BS EN
60839-11 series of standards had not become widely specified due to in part to the lack of
component certification, NSI have taken the decision not to implement a certification scheme
for these standards.
NSI will keep this decision under review and will develop a scheme if, in future, there is sufficient
interest within the marketplace for certification to the BS EN 60839-11 series.
1 Scope
This Code of Practice contains requirements and recommendations for the design,
installation, commissioning and maintenance of electronic ACS(s) used for physical
access (entry and exit) in and around buildings and protected areas. It is intended for use
in security applications for the granting of, or preventing, access and includes
requirements for logging, identification and control of information; it does not include
requirements for access point actuators and sensors.
The following are outside the scope of this Code of Practice and must not be certificated:
a) Systems where a person makes the decision as to whom may enter or exit the
premises or protected area.
Example: A door entry telephone system used in conjunction with an electrically
operated.
b) Lock triggered by a person using a manual switch/button.
c) Where the entire system is housed within a single unit/housing controlling a
single access point and located at the access point being controlled, with no
interconnections to control equipment or system management database
located away from the access point. This exemption does not include systems
with more than one access point for the controlled area.
Note: The recognition device and or request to exit button/switch used for this
single access point can be installed external to the single unit/housing.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 4 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Note 1: A unit/housing containing a bolt or pin and the striking plate or box into which the
bolt or pin is thrown is considered to be a single unit/housing.
Note 2: Electrical wiring, radio links, laser-links, fibre-optic links and mains borne signalling
are examples of interconnections (but refer to Note 3 below which allows an exemption for
electrical supply failure auto-release facilities).
Note 3: The provision of an auto-release, such that the access point releases in the event of
failure of an electrical supply system, is not regarded for the purposes of c) above as
amounting to an interconnection to control equipment or system management database
located away from the access point.
2 References
The following referenced standards are indispensable for the application of this Code of
Practice
BS EN 60529 - Degrees of protection provided by enclosures (IP code)
BS EN 62262:2002 - Degrees of protection provided by enclosures for electrical
equipment against external mechanical impacts (IK code)
BS 7273-4 - Actuation of release mechanisms for doors
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 5 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
3.1.6 Adversary
Person or persons deliberately attempting to overcome the ACS with malicious intent.
3.1.8 Biometric
Any measurable, unique physiological characteristic or personal trait that is used as a
credential to recognise and verify the identity of an individual’s dynamics.
Examples: Fingerprint, hand or face geometry, retinal/eye pattern, voice pattern or
signature or keyboarding dynamics etc..
3.1.10 Commissioning
The completion of installation and final checking of an ACS prior to its handover.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 6 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
3.1.15 Credential
Any token or memorised information or biometric used to identify an individual to an
ACS in order to verify user access.
Examples: Access fob, card, mobile phone, etc.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 7 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
3.1.24 Keypad
A data entry point for the input of a numeric or alphanumeric code into an ACS.
3.1.31 Reader
Device for the input of credentials.
3.1.32 Recognition
Process by which the ACS determines the credentials prior to comparing them against
the processing rules.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 8 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
3.1.40 Token
Portable device containing a readable unique identifier (credential) that can be
associated with a user's data and access rights stored within the electronic access control
system.
3.1.41 Transaction
A recognisable event occurring within an ACS, such as the release of a door following
presentation of a valid credential or the generation of a door alarm report.
An example of a door alarm report would be an 'access point held open' alarm.
3.2 Abbreviations
ACS Access Control System
ACU Access control Unit
CIE Control and Indicating Equipment
LAN Local Area Network
PoE Power over Ethernet
UPS Uninterruptable Power Supply
UTC Coordinated Universal Time
WAN Wide Area Network
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 9 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
4.1 General
Access points are classified by the requirements for successful legitimate access and the
level of security that they provide.
The access point class can change according to risk, e.g. where the risk is higher during
hours of darkness a higher class may be required for that period of time.
For each class, access may be granted using credentials permitted at higher classes, but
not when using credentials only permitted at lower classes.
The classification of access points and associated level of security shall be determined as
the result of a site risk assessment which may be carried out in conjunction with the
customer.
The location and classification of each of the access points making up an ACS must be
identified in the system design proposal and in the as-fitted document.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 10 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Class I II III IV
Risk Level Low Low to Medium Medium to High High
Application Operational Operational Operational Operational
needs needs needs needs
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 11 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Class I II III IV
Skill level of Low skill, low Medium skill & High skill & Very high skill
adversaries/attackers knowledge of knowledge of knowledge of and knowledge
ACS, low ACS, low ACS, medium of ACS, high
knowledge of knowledge of knowledge of knowledge of
token & IT token & IT token & IT token & IT
technologies technologies technologies technologies
Low financial Low to medium Medium financial High financial
means for attack financial means means for attack means for
for attack attack
Each credential reader must fulfil the requirements detailed in Table 2 according to the
defined access point class.
Access shall be denied after each attempt to gain access using invalid credentials.
Suspending access after several sequential incorrect attempts to gain access may be
considered.
In normal mode of operation the system shall use complete token information (facility
code and card number, or unique card number) for recognition. In degraded mode of
operation the system may use partial token information (e.g. facility code only) for
recognition.
Where the token identity number is readable on the token, it must not be a direct
representation of the credential coding used to gain access.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 12 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Note:
10,000 differs requires a 4-digit code number such as 1234.
1,000,000 differs requires a 6-digit code number such as 123456.
RFID must not rely on recognising the Chip Serial Number (CSN) only. Also, the code to
be read must be stored in the memory of the card.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 13 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
5 Design
5.1 Survey
A survey may be a physical inspection of the areas to be controlled at the premises, a
review of plans or design drawings or a combination of both.
As the performance and reliability of an ACS is determined by several factors, it is of
importance that as much information as possible is gathered to produce a robust design,
addressing the environmental, physical and the operational needs of the end user.
It is imperative that, wherever possible, all relevant interested parties within the
organisation or who provide relevant services to the organisation should be consulted. This
may include the IT department or a third-party IT support provider etc.
The classification of each access point shall be determined taking into consideration the
needs for control of access and egress, and the overall level of security to be provided at
each access point.
Access points of different classes can be used on the same system provided that any
common system components for each access point meet the requirements for the
highest class that they are associated with.
The suitability of any ACS must be considered in relation to the fire strategy for the
premises and the need for safe egress in emergency situations.
Where applicable, the methods to be used to release all the access points (for example
green coloured single action emergency exit buttons, or break glass units, on the secure
side of access points) must be agreed and these must be documented in the system
design proposal and the as-fitted document.
The means to release electronically secured doors and powered sliding doors in the
event of a fire should meet the recommendations of BS 7273-4.
Access points must not:
a) conflict with building/fire regulations;
b) restrict exit in such a way as to endanger people in an emergency.
The following aspects must be considered when designing an ACS to meet the risks
detailed in the documented risk assessment.
a) The number of access points required to provide the required level of security
for the controlled area or areas.
b) How access points will operate in the event of mains power failure and the
period, or number of transactions, required in such situations.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 14 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 15 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
5.2 Credentials
Credentials may be thought of in terms of something you know (code), something you have
(token) or something you are (biometric).
The security, size and durability of a credential are dependent upon the technology used
to encode it and the equipment required to read it.
Credential technology should be selected as appropriate to the protected risk and the needs
of the customer.
Listed below are some examples of common types of available credential:
− Memorised information such as common codes and PIN codes, which are input
by hand onto a keypad
− Radio Frequency Identification (RFID)
− QR Code / Barcode
− Near Field Communication (NFC)
− Biometric
When selecting a battery powered active token, the life span of the battery as well as the
environment in which the token will be required to operate and the frequency of its use
must be taken into account.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 16 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
5.3 Functionality
Access control equipment must provide appropriate levels of functionality for each class
of access point in accordance with clauses 5.3.1 to 5.3.7.
Where functions are indicated in the table associated with each section as being optional,
their inclusion or omission must be determined by the risk assessment and/or
operational requirement.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 17 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 18 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 19 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
The features detailed in Table 6 must be provided according to the access point
classification.
When biometrics are used, the system will normally have a decision threshold adjustment
that can modify the False Acceptance Rate (FAR) and False Rejection Rate (FRR). These
settings should be discussed with the user to ensure the balance between the need for
security and the need for operability is met. If the FAR is high, it will be more likely that an
unauthorised person will be able to gain access using their biometric. However, if the FRR
is set too high, this may make the system too sensitive and prevent authorised users
accessing the secure location.
Where the customer has been provided with the means to adjust biometric readers, the
access to the means of adjustment must be protected against unauthorised change (for
example by requiring an authorised person to enter a password) and sufficient
information to enable them to understand the consequences of making adjustments
must also be provided.
For example, the customer might be provided with information about the adjustments of
their biometric readers that are acceptable and/or unacceptable for their security
application.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 20 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Indication of the lock status at each access point may also be required based on the risk
assessment.
Central indication and annunciation facility requirements in Table 7 must be provided
according to the access point classification.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 21 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
6.1 Control
Control equipment must be capable of providing the required functionality that has been
determined by the risk assessment and survey during the design process.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 22 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
d) The effect that the access point hardware may have of the physical strength of
the access point.
Access point hardware such as locking mechanisms should be selected
appropriate to the strength of the door and its frame.
The physical strength of the access point should not be reduced by the fitting of
such hardware.
Where the fitting of access point hardware to meet the specific class of access
point, as identified in the risk assessment, would result in a reduction in the
physical strength of the access point, there should be consultation with the end
user to ensure that suitable reinforcement of the access point is undertaken.
Where the reinforcement of the access point is not possible, the classification of
the access point may need to be reduced. (e.g. where the risk assessment identifies
that an access point of class III is required, but the physical strength of the access
point would only permit the fitting of access point hardware meeting the
requirements of class II etc.). Any such circumstance should be documented in the
system design proposal, as-fitted documentation and risk assessment.
e) The minimum holding force of any powered locks required.
f) The holding force required should be suitable to protect against the risk
identified in the risk assessment.
Holding forces per access class are typically considered to be:
• Class I Holding Force = 3kN/300kg or more
• Class II Holding Force = 5kN/500kg or more
• Class III Holding Force = 7kN/700kg or more
• Class IV Holding Force = 10kN/1000kg or more
g) The characteristics of the door such as rebate and double rebated doors.
h) Any necessary safety precautions for glass or other special doors.
i) Door closing devices should be sufficient to close and lock the door under
normal circumstances.
j) The fire resistance of the access point.
Not all access point hardware (e.g. locks and locking mechanisms) is suitable for
use on fire doors, therefore particular regard should be given to the integrity of
the fire resistance and how it may be affected by the fitting of the access point
hardware and any associated cabling etc. Advice should be sought from the fire
door manufacturers regarding the possible effect on the integrity of the fire door
when fitting access point hardware.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 23 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 24 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Certain release mechanisms associated with an ACS, such as those for roller shutters, may
operate at mains voltage and specific electrical safety requirements will apply to these.
Where safety and security considerations do not require continued operation of a system
during a mains supply failure, the public mains supply via a safety isolating transformer
may be the sole supply for the system. A 'clean' source for this may be required in
electrically noisy environments.
It is preferable for the ACS to have its own dedicated final mains circuit.
Power supply units must be located within controlled areas and in positions secure from
tampering. Additional security must be provided for power supply units that support fail
unlocked hardware.
Additional security measures to be considered may include installation of equipment above
false ceilings, enclosures that can only be opened by means of a special tool (i.e. a tool not
likely to be carried by a member of the general public) or using tamper proof or monitored
enclosures etc.
The mains power supply must be permanently connected to the ACS via an un-switched
fused spur, dedicated to the ACS.
Extra low voltage cables must not enter a power supply enclosure through the same
entry point as any low voltage (mains cables).
Where continued operation of all or part of the ACS is essential during mains supply
failure, standby power supplies, with the capacity to support the system for not less than
the minimum period agreed with the customer, must be provided according to the
access point classification in Table 8.
Some types of actuators may be excluded from the standby power supply
requirements/calculations (e.g. directly AC powered and/or for high power consumption)
provided it has been agreed with the user and recorded in the system design proposal
and as-fitted document.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 25 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
7 Installation
Readers must be mounted:
a) securely in position; and
b) adjacent to their access points and in positions convenient for all users to use,
including those with disability.
Attention is drawn to relevant national building regulations.
When fitting access point hardware (including locks, latches and locking plates) to fire
door sets, guidance from the manufacturer of the fire door sets must be followed.
Access point hardware (including locks, latches and locking plates) should not introduce
any hazards that could result in injury (e.g. head injury due to frame hung locking device
etc.)
The following must be taken into consideration when siting control equipment:
a) Ventilation
b) Access for maintenance.
c) User access for archiving, etc.
d) Noise from associated printer.
e) Physical security and supervision.
f) General visibility to unauthorised people of any displayed data.
7.1 Cables
7.1.1 General
Attention is drawn to BS 7671 (the I.E.T Wiring Regulations).
Cable types selected must meet manufacturer’s recommendations or have the required
performance to meet the electrical characteristics required to support the connected
devices and be suitable for the environment in which they are installed.
Where practicable, cables must be installed within controlled areas and be concealed or
in containment.
Where cables are exposed to possible mechanical damage or tampering, or are outside
controlled areas, they must be mechanically protected.
All interconnecting wiring must be supported and its installation must conform to good
working practice.
Particular attention is drawn to BS 7671 (the I.E.T Wiring Regulations) in respect of the
requirements for cable supports that resist premature collapse in the event of fire.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 26 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
All extra low voltage cable joints must be made in suitable junction boxes using either
soldered, crimped, or screw-terminals.
Extra low voltage signal cables should not be run in close proximity to mains power cables
or other low or high voltage cables.
Where it is not possible to separate cables or where mains or other cables may be
installed with signal cables in the future, for example where signal cabling is run in open
cable trays, the cable insulation of the ACS cables must be rated at or greater than the
highest voltage of adjacent cables.
Where cables are part of the ‘critical path’ for door release mechanisms the
recommendations of BS 7273-4 should be followed.
BS7273-4 defines ‘critical signal path’ as: “all interconnections and communications
between a fire alarm system and the input terminals on, or within (a) device(s) provided to
open, release or unlock a door, or between CIE and other control equipment by which such
devices are controlled”.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 27 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
In very simple point to point systems where the relationship between devices and cables
can be reasonably determined, a cross reference chart or running out diagram may not be
necessary. Patch cables having a specific colour unique to the ACS is recommended.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 28 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
changing/hiding the Service Set Identifier (SSID), changing default passwords and IP
addresses and using suitable encryption protocols.
8.1.1 Commissioning
The following must be checked and verified during the commissioning process:
a) All wiring is correctly terminated.
b) Voltage and resistance at all appropriate points (e.g. where voltage drop or
high resistance would have an adverse effect on the operation of the ACS) of
the system are correct and recorded.
c) Alignment and operation of access point hardware and of release and closure
mechanisms at each access point is operating correctly.
d) Emergency release mechanisms at all the access points operate correctly and
manual controls are clearly identifiable and labelled.
e) Emergency release mechanisms operate correctly under fire alarm conditions.
f) Operation of each reader is correct.
g) Release time for each door is correct.
h) Specific security requirements, such as time of day operation and event
notifications, such as door held open, door forced, anti-passback, etc., all
function correctly.
i) Correct authorisation of access is verified by the input of appropriate data.
j) ACS continues to work when mains supply disconnected (if specified).
k) All system security measures are functioning correctly.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 29 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
l) All system application and operating software is at the correct and up to date
version with any outstanding application and security patches and appropriate
upgrades installed, subject to any software configuration controls the
customer may have in place.
m) Any standby power supplies required to support the system in the event of a
mains failure are verified as being capable of supporting the system for the
required duration and the results recorded.
n) All unused TCP/UDP ports should be closed.
o) All unused system protocols should be disabled e.g. port 23 (typically Telnet).
At the end of commissioning, all unused user accounts must be deleted or disabled and
details of accounts and passwords provided to the user.
Permission for the installing company to retain details of user accounts and passwords
for ongoing maintenance activities must be agreed in writing.
8.2 Handover
The following must take place during the handover process:
a) Ensure there is a facility to record any system events (e.g. this could be in the
form of an electronic event log or hardcopy logbook).
b) Ensure the end user is aware of how to report any issues that require attention
by the maintenance company.
c) Demonstrate all aspects of system operation to the customer, including any
necessary safety precautions and any standby power facilities.
d) Ensure that the correct documentation (see 8.3) is given to the customer to
enable the system to be correctly operated, adjusted and maintained.
e) Provide details and training of end user maintenance responsibilities for the
system, with particular emphasis on:
• regular system back-ups;
• database management & password security;
• Cyber Security
• visual checks on door furniture;
• periodic maintenance of door furniture and correct operation of door
closers;
• correct release of access point on activation of the fire alarm system
(where applicable) during the weekly fire alarm test;
• correct operation and resetting of any manual override switching.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 30 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
f) Provide the user with any software and or software licenses purchases by the
customer.
g) Ensure that users are aware of any procedures to be followed in the event of a
system malfunction.
These may be additional physical measures to maintain the level of security
normally provided by the ACS
h) Advise the end user of their obligation to comply with any legal requirements
under the Data Protection Act and UK GDPR.
i) Ensure that written permission has been obtained where a user code(s) are to
be retained by the installation/maintenance company for ongoing
maintenance purposes.
Any such arrangements should have been determined at the design/survey stage.
j) Where an ACS is managed remotely, the details of this should be included in
the documentation (see 8.3), for example the means to interface to the system,
the level of access and details of sites with remote access.
k) Issue a NSI Certificate of Compliance in accordance with NSI Regulations.
8.3 Documentation
A documented risk assessment must be produced as part of the design process.
A system design proposal must be developed that includes all the customer’s
requirements, features and functionality of the ACS as well as any limitations or
exclusions (based on risk assessment). Any user responsibilities or provisions should also
be included.
Where a standby power supply facility is to be provided, the system design proposal
must include either the minimum duration of the standby supply in hours or the
minimum number of actuations per hour for each applicable access point.
BS EN 60839-11-2, Annex B gives information on how battery standby capacity can be
calculated.
The system design proposal must be agreed with the user or their representative prior
to commencement of the installation.
Upon completion of installation of the ACS an as-fitted document, including the
following information, must be provided:
a) The address of the premises where the ACS is installed.
b) The location and classification of each access point and the type and location
of each controller and its associated hardware (for example the type of
token/reader technology).
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 31 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
9 Maintenance
9.1 Resources
9.1.1 General
It is advisable the installing company should also carry out the maintenance.
The organisation responsible for the maintenance of the ACS must have the means,
including spare parts and documentation to comply with this Code of Practice.
This recommendation does not place an obligation upon customers to have their ACS
maintained, maintenance is a matter of agreement between the installing company and
the customer or between the customer and a separate maintenance company. However,
where an ACS controls access points that are also fire exits the customer should be
advised to put a maintenance agreement in place to ensure the system continues to
operate correctly.
Where a computer based system is installed, the customer should be advised to consider
having a support agreement with the software supplier, where the organisation
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 32 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
responsible for the maintenance of the ACS does not provide the necessary software
support this is to ensure updates to the application and technical support can be
provided.
The organisation responsible for the maintenance of the ACS must ensure the safe
custody and control of all equipment and documentation pertaining to installations,
which is within their control.
9.2.2 Inspection
During each preventive maintenance visit, the following should be inspected and any
necessary corrective action should be carried out in agreement with the customer:
a) The installation, location and siting of all equipment and devices against the
as-fitted document (see 8.3).
b) The satisfactory operation of all equipment.
c) All flexible connections.
d) The normal and standby power supplies, for correct functioning.
e) The control equipment, in accordance with your procedure.
f) The operation of any warning device in the system
g) The correct operation of all system security functions
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 33 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
h) System application and operating software is at the correct version with the
latest security patches and critical updates installed, subject to any software
configuration controls the customer may have in place.
i) Verify customer responsibilities have been carried out, and inform the
customer of any required corrective actions.
Those items of inspection and rectification which are not carried out during the
preventive maintenance visit must be documented and agreed with the customer. These
should be completed as soon as practicable, subject to the customer agreement.
Any reduction in the level of security identified during the preventative maintenance visit
must:
• be recorded on the maintenance visit;
• be subject to a review of the risk assessment; and
• be rectified as soon as is practicable.
Rectification of any issues resulting in the reduction of the level of security may be outside
of the scope of the maintenance organisation.
Where the risk assessment has not been made available to the maintenance organisation,
a new assessment may need to be undertaken.
9.4 Records
9.4.1 General
The organisation responsible for the maintenance of the ACS must maintain records
relating to the ACS it maintains, including the information required as detailed in sections
9.4.2 to 9.4.5. It is essential that these records are protected from unauthorised access.
Attention is drawn to the General Data Protection Regulation (GDPR) and the 2018 Data
Protection Act (DPA). In those cases where records contain information concerning
individuals.
You must retain information in respect of contracts (including survey, design, quotations,
amendments and commissioning/handover documents for the life of the contract plus a
minimum of two (2) years.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 34 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 35 of 36
© NSI 2021
NSI Code of Practice for the design, installation, commissioning and
maintenance of Access Control Systems
A corrective maintenance visit record must be produced for each corrective maintenance
visit.
A corrective maintenance visit record must include the details of the reason for the
corrective maintenance visit and the work undertaken, including any modifications or
remedial works.
Any corrective maintenance work not completed should be recorded, including the
reason why and accepted by the client or their representative.
A record of checks and work carried out must be given to the customer at the time of
maintenance or provided within 10 days or as agreed with the customer.
The organisation responsible for the maintenance of the ACS must retain corrective
maintenance records for a minimum period of 15 months after the corrective
maintenance visit has taken place.
If a preventive maintenance inspection is made at the same time as the corrective
maintenance visit, these should be recorded as separate records.
Document no. NCP 109 Document issue no. 3 Document issue date June 2021
Document owner Head of Approval Schemes Last review date June 2021
Document classification PUBLIC (RESTRICTED) Page 36 of 36