0% found this document useful (0 votes)
28 views48 pages

Ruijie RG-S2910-H Series Switches Hardware Installation and Reference Guide V1.32

mantap

Uploaded by

FIRMAN TIMUR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views48 pages

Ruijie RG-S2910-H Series Switches Hardware Installation and Reference Guide V1.32

mantap

Uploaded by

FIRMAN TIMUR
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 48

Ruijie RG-S2910-H Series Switches

Hardware Installation and Reference Guide V1.32


Copyright Statement

Ruijie Networks©2020

Ruijie Networks reserves all copyrights of this document. Any reproduction, excerption, backup, modification,
transmission, translation or commercial use of this document or any portion of this document, in any form or by any means,
without the prior written consent of Ruijie Networks is prohibited.

Exemption Statement

This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain
the latest information through the Ruijie Networks website. Ruijie Networks endeavors to ensure content accuracy and will
not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
Preface

Thank you for using our products. This manual will guide you through the installation of the device.

This manual describes the functional and physical features and provides the device installation steps, hardware
troubleshooting, module technical specifications, and specifications and usage guidelines for cables and connectors.

Audience

It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it
is assumed that the users are already familiar with the related terms and concepts.

Obtaining Technical Assistance

 Ruijie Networks Website: https://www.ruijienetworks.com/

 Technical Support Website: https://ruijienetworks.com/support

 Case Portal: https://caseportal.ruijienetworks.com

 Community: https://community.ruijienetworks.com

 Technical Support Email: [email protected]

 Skype: [email protected]

Related Documents

Documents Description

Describes network protocols and related mechanisms that


Configuration Guide
supported by the product, with configuration examples.

Describes the related configuration commands, including


Command Reference command modes, parameter descriptions, usage guides, and
related examples.

Symbol Conventions

The symbols used in this document are described as below:

This symbol brings your attention to some helpful suggestions and references.

This symbol means that you must be extremely careful not to do some things that may damage the device or cause
data loss
Hardware Installation and Reference Guide Product Overview

1 Product Overview
The RG-S2910-H series switch is a next-generation intelligent switch that features high performance, high security,
multiple services and ease of use to meet the needs of the current networks. The RG-S2910-H series switch can provide
the complete end-to-end Quality of Service (QoS), flexible and abundant security policies and policy-based network
management for various networks. It is greatly ideal for such applications as campus network, enterprise network,
government network, service network, residential broadband access and business building network, providing high-speed,
high-efficiency, secure and intelligent access solutions.

Table 1-1 RG-S2910-H

Pluggable
10/100/1000 Base-T SFP+ 1000Base-X Console USB
Model Power
Auto-sensing Ethernet Port Port SFP Port Port Port
Slot
24 (All are PoE+ capable.
RG-S2910-24GT4SFP-UP-H \ 4 1 \ \
Ports 1-4 are HPoE capable)
10 (Ports 1-8 are HPoE
RG-S2910-10GT2SFP-UP-H \ 2 1 \ \
capable)
24 (All are PoE+ capable.
RG-S2910-24GT4XS-UP-H 4 \ 1 \ \
Ports 1-4 are HPoE capable)

The SPF+ ports are downward compatible with 1000Base-X. The SFP ports only support 1000Base-X modules.

1000Base-T is compatible with 100Base-TX and 10Base-T in the downlink direction.

For RG-S2910-24GT4SFP-UP-H /RG-S2910-24GT4XS-UP-H, the HPoE ports support 60W power supply and
support IEEE 802.af/at PoE.

For RG-S2910-10GT2SFP-UP-H, the HPoE ports support 95W power supply and support IEEE 802.af/at PoE.

1.1 RG-S2910-24GT4SFP-UP-H

Technical Specifications

Model RG-S2910-24GT4SFP-UP-H
CPU Built-in CPU, single-core processor, 1GHz
V1.XX: 512MB
Flash Memory
V2.XX/V3.XX/ V4.XX/V6.XX: 256MB
SDRAM DDRIII 512MB
For details, see Appendix B.
Optical Module
The supported module type may change at any time. Consult us for the latest information.

Supports 1000Base-X modules. Does not support 100Base-FX.

SFP Port When the SFP ports are used as stack ports:
When used as stack ports, SFP ports of hardware versions V1.XX only support 10G DAC
copper cables (XG-SFP-CU1M, XG-SFP-CU3M and XG-SFP-CU5M); SFP ports of
Hardware Installation and Reference Guide Product Overview

hardware versions V2.XX, V3.XX, V4.XX and V6.XX support 10G DAC copper cables
(XG-SFP-CU1M, XG-SFP-CU3M and XG-SFP-CU5M), 2.5G DAC copper cables
(GE-SFP-STACK1.6M), and SFP transceiver modules.

 AC input

Rated voltage range: 100V to 240V


Maximum voltage range: 90V to 264V
Frequency: 50/60 Hz
Power Supply
Rated current: 6.8A

 HVDC input

Voltage range: 192V to 290V


Current range: 2.5A to 3.5A
Earth Leakage
≤ 0.5mA
Current
EEE Supported

Version below V6.XX: All the RJ45 ports are PoE-capable. Ports 1-4 are HPoE-capable with
the maximum power output of 60W. Ports of hardware versions V1.XX and V2.XX support the
maximum power of 90W. Ports of hardware versions V3.XX and V4.XX support the maximum
power of 60W. Ports 5-24 support the maximum power output of 30W.
V6.XX: All the RJ45 ports are PoE-capable. Ports 1-24 support the maximum power output of
30W.

The maximum output power of PoE/PoE+/HPoE is 370W.The HPoE ports support the
PoE
maximum power supply of 60W only when connected with HPoE PDs. For example,
RG-PBOX-DC12 and RG-PBOX-AC24.

HPoE ports support IEEE 802.af/at PoE.

The available number of PDs is determined by PSE output power and PD input power in
practice.

For PoE port, the pinout of the network cable is “1,2,3,6”.

For HPoE port, the pinout of the network cable can be “1,2,3,6” and “4,5,7,8”.

Power Less than 40W with no PoE load


Consumption Less than 460W with PoE full load
Operating
0℃ to 50℃ (32°F to 122°F)
Temperature
Storage
-40℃ to 70℃ (-40°F to 158°F)
Temperature
Operating Humidity 10% to 90% RH
Storage Humidity 5% to 95% RH
Fan Speed adjustment and fault alarm
Temperature
Supported
Warning
Hardware Installation and Reference Guide Product Overview

GB/T 9254.1
EN 300 386
EN 61000-3-2
EN 61000-3-3
EN 61000-4-2
EN 61000-4-3
EMCStandards EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-11
EN 55032
EN 55035
EN 61000-4-8
GB 4943.1
Security Standards EN62368-1
IEC62368-1
Dimensions
440 mm x 260 mm x 44 mm
(W x D x H)
Weight ≤5.5 kg (with package)

In a domestic environment, this product may cause radio interference.

Product Appearance

On the front panel, the RG-S2910-24GT4SFP-UP-H Ethernet switch provides 24 10/100/1000Base-T Ethernet ports, 4
SFP ports, and 1 Console port. On the back panel, it provides AC power ports.

Figure 1-1 Appearance of RG-S2910-24GT4SFP-UP-H

Front Panel

Figure 1-2 Front Panel of RG-S2910-24GT4SFP-UP-H


Hardware Installation and Reference Guide Product Overview

Note: 1. System status LED 6. Console port

2. PoE status LED 7. 10/100/1000Base-T auto-sensing Ethernet port

3. Copper port status LED 8. 1000Base-X SFP port

4. Fiber port status LED 9. 1000Base-X SFP port

5. PoE Mode Switch-Over Button

Long press PoE Mode Switch-Over Button for above 2 seconds to switch the display mode between PoE mode and
port rate mode.

Back Panel

Figure 1-3 Back Panel of RG-S2910-24GT4SFP-UP-H

Note: 1. Grounding pole

Power Supply

The RG-S2910-24GT4SFP-UP-H switch adopts AC or HVDC power input.

 AC input

Rated voltage range: 100V to 240V

Maximum voltage range: 90V to 264V

Frequency range: 50/60 Hz

Rated current: 6.8A

Power cord specification: 10A

 HVDC input

Voltage range: 192V to 290V

Current range: 2.5A to 3.5A

Heat Dissipation

The RG-S2910-24GT4SFP-UP-H adopts turbine fans for heat dissipation, thereby ensuring normal function of the device
in the specified environment. 10 cm distance space should be reserved at both sides and the back plane of the cabinet to
Hardware Installation and Reference Guide Product Overview

allow air circulation. It is recommended to clean the device once every 3 months to avoid dust from blocking vents. Figure
1-4 shows the flow scheme of heat dissipation.

Figure 1-4 Flow Scheme of Heat Dissipation

LEDs

LED Panel Identification State Meaning

Off The switch is not receiving power.

The system is being initialized.


Blinking green
Continuous blinking indicates errors.

Solid green The switch is operational.


System status LED Status

Temperature warning

Solid yellow Check the working environment of the switch


immediately.

Solid red The switch is faulty.

Solid green Indicates the switching state.


PoE status LED PoE
Solid yellow Indicates the PoE state.

1-24 Off The port is not connected.


Hardware Installation and Reference Guide Product Overview

1000Mbps RJ-45 port


Solid green The port is connected at 1000 Mbps.
status LED

The port is receiving or transmitting traffic at 1000


Blinking green
Mbps.

Solid yellow The port is connected at 10/100 Mbps.

The port is receiving or transmitting traffic at


Blinking yellow
10/100 Mbps.

Off PoE is not enabled.

RJ45 port PoE status


1-24 Solid green PoE is enabled. The port is operational.
LED

Solid yellow The PoE port is abnormally operational.

Off The port is not connected.

1000Mbps SFP port Solid green The port is connected at 1000 Mbps.
25F-28F
status LED
The port is receiving or transmitting traffic at 1000
Blinking green
Mbps.

1.2 RG-S2910-24GT4XS-UP-H

Technical Specifications

Model RG-S2910-24GT4XS-UP-H
CPU Built-in CPU, single-core processor, 1GHz
Flash Memory 512M
SDRAM DDRIII 512MB
For details, see Appendix B.
Optical Module
The supported module type may change at any time. Consult us for the latest information.

Supports 10GBase-R and 1000Base-X modules.

SFP Port When used as stack ports, SFP+ ports support 10G DAC copper cables (XG-SFP-CU1M,
XG-SFP-CU3M, and XG-SFP-CU5M) and SFP+ transceiver modules.

 AC input

Rated voltage range: 100V to 240V


Power Supply
Maximum voltage range: 90V to 264V
Frequency: 50/60 Hz
Rated current: 6.8A
Hardware Installation and Reference Guide Product Overview

 HVDC input

Voltage range: 192V to 290V


Current range: 2.5A to 3.5A
EEE Supported
Earth Leakage
≤0.5mA
Current
Version below V4.XX: All the RJ45 ports are PoE-capable. Ports 1-4 are HPoE-capable with
the maximum power output of 60W. Ports of hardware versions V1.XX support the maximum
power of 90W. Ports of hardware versions V3.XX support the maximum power of 60W. Ports
5-24 support the maximum power output of 30W.

V4.XX: All the RJ45 ports are PoE-capable. Ports 1-24 support the maximum power
output of 30W.The maximum output power of PoE/PoE+/HPoE is 370W.The HPoE ports
support the maximum power supply of 60W only when connected with HPoE PDs. For
PoE
example, RG-PBOX-DC12 and RG-PBOX-AC24.

HPoE ports support IEEE 802.af/at PoE.

The available number of PDs is determined by PSE output power and PD input power in
practice.

For PoE port, the pinout of the network cable is “1,2,3,6”.

For HPoE port, the pinout of the network cable can be “1,2,3,6” and “4,5,7,8”.

Power Less than 40W with no PoE load


Consumption Less than 460W with PoE full load
Operating
0℃ to 50℃ (32°F to 122°F)
Temperature
Storage
-40℃ to 70℃ (-40°F to 158°F)
Temperature
Operating Humidity 10% to 90%
Storage Humidity 5% to 95%
Fan Speed adjustment and fault alarm
Temperature
Supported
Warning
EMCStandards GB/T 9254.1
Security Standards GB 4943.1
Dimensions
440 mm x 260 mm x 44 mm
(W x D x H)
Weight ≤5.5 kg (with package)

In a domestic environment, this product may cause radio interference.

Product Appearance

On the front panel, the RG-S2910-24GT4XS-UP-H Ethernet switch provides 24 10/100/1000Base-T Ethernet ports, 4
SFP+ ports, and 1 Console port. On the back panel, it provides AC power ports.
Hardware Installation and Reference Guide Product Overview

Figure 1-5 Appearance of RG-S2910-24GT4XS-UP-H

Front Panel

Figure 1-6 Front Panel of RG-S2910-24GT4XS-UP-H

Note: 1. System status LED 5. PoE Mode Switch-Over Button

2. PoE status LED 6. Console port

3. Copper port status LED 7. 10/100/1000Base-T auto-sensing Ethernet port

4. Fiber port status LED 8. SFP+ port

Long press PoE Mode Switch-Over Button for above 2 seconds to switch the display mode between PoE mode and
port rate mode.

Back Panel

Figure 1-7 Back Panel of RG-S2910-24GT4XS-UP-H

Note: 1. Grounding pole

Power Supply

The RG-S2910-24GT4XS-UP-H switch adopts AC or HVDC power input.

 AC input

Rated voltage range: 100V to 240V

Maximum voltage range: 90V to 264V

Frequency range: 50/60 Hz


Hardware Installation and Reference Guide Product Overview

Rated current: 6.8A

Power cord specification: 10A

 HVDC input

Voltage range: 192V to 290V

Current range: 2.5A to 3.5A

Heat Dissipation

The RG-S2910-24GT4XS-UP-H adopts turbine fans for heat dissipation, thereby ensuring normal function of the device in
the specified environment. 10 cm distance space should be reserved at both sides and the back plane of the cabinet to
allow air circulation. It is recommended to clean the device once every 3 months to avoid dust from blocking vents. Figure
1-8 shows the flow scheme of heat dissipation.

Figure 1-8 Flow Scheme of Heat Dissipation

LEDs

LED Panel Identification State Meaning

Off The switch is not receiving power.

The system is being initialized.


System status LED Status Blinking green
Continuous blinking indicates errors.

Solid green The switch is operational.


Hardware Installation and Reference Guide Product Overview

Temperature warning

Solid yellow Check the working environment of the switch


immediately.

Solid red The switch is faulty.

Solid green Indicates the switching state.


PoE status LED PoE
Solid yellow Indicates the PoE state.

Off The port is not connected.

Solid green The port is connected at 1000 Mbps.

The port is receiving or transmitting traffic at 1000


Blinking green
1000Mbps RJ-45 port 1-24 Mbps.
status LED
Solid yellow The port is connected at 10/100 Mbps.

The port is receiving or transmitting traffic at


Blinking yellow
10/100 Mbps.

Off PoE is not enabled.

RJ45 port PoE status


1-24 Solid green PoE is enabled. The port is operational.
LED

Solid yellow The PoE port is abnormally operational.

Off The port is not connected.

SFP+ port status LED 25F-28F Solid green The port is connected.

Blinking green The port is receiving or transmitting traffic.

1.3 RG-S2910-10GT2SFP-UP-H

Technical Specifications

Model RG-S2910-10GT2SFP-UP-H
CPU Built-in CPU, single-core processor, 400MHz
Flash Memory 256M
SDRAM DDRIII 512MB
Hardware Installation and Reference Guide Product Overview

Supports 1000base-X only. For details, see Appendix B.


Optical Module
The supported module type may change at any time. Consult us for the latest information.

SFP Port Supports 1000Base-X modules.

 AC input

Rated voltage range: 100V to 240V


Maximum voltage range: 90V to 264V
Frequency: 50/60 Hz
Power Supply
Rated current: 8A

 HVDC input

Voltage range: 192V to 290V


Current range: 0A to 6A
Earth Leakage
≤ 3.5mA
Current
EEE Supported
Ports 1-8 are HPoE-capable with the maximum power output of 95W.
The maximum output power is as follows.

 AC input

90 to175VAC: 380W
175 to 264VAC: 760W

 HVDC input

192 to 220VDC: 380W


220 to 290VDC: 760W
PoE
The HPoE ports support the maximum power supply of 95W only when connected with
HPoE PDs. For example, RG-PBOX-DC12 and RG-PBOX-AC24.

HPoE ports support IEEE 802.af/at PoE.

The available number of PDs is determined by PSE output power and PD input power in
practice.

For PoE port, the pinout of the network cable is “1,2,3,6”.

For HPoE port, the pinout of the network cable can be “1,2,3,6” and “4,5,7,8”.

Power Less than 30W with no PoE load


Consumption Less than 870W with full PoE load
Operating
0℃ to 50℃ (32°F to 122°F)
Temperature
Storage
-40℃ to 70℃ (-40°F to 158°F)
Temperature
Operating Humidity 10% to 90%
Storage Humidity 5% to 95%
Fan Speed adjustment and fault alarm
Temperature Supported
Hardware Installation and Reference Guide Product Overview

Warning
EMCStandards GB/T 9254.1
Security Standards GB 4943.1
Dimensions
340 mm x 260 mm x 44 mm
(W x D x H)
Weight ≤4.0 kg (with package)

In a domestic environment, this product may cause radio interference.

Product Appearance

On the front panel, the RG-S2910-10GT2SFP-UP-H Ethernet switch provides 10 10/100/1000Base-T Ethernet ports, 2
SFP ports, and 1 Console port. On the back panel, it provides AC power ports.

Figure 1-9 Appearance of RG-S2910-10GT2SFP-UP-H

Front Panel

Figure 1-10 Front Panel of RG-S2910-10GT2SFP-UP-H


Hardware Installation and Reference Guide Product Overview

Note: 1. System status LED 7. PoE Mode Switch-Over Button

2. PoE status LED 8. Console port

3. 10/100/1000Base-T auto-sensing Ethernet 9. 10/100/1000Base-T auto-sensing Ethernet port


port
10. 1000Base-X SFP port
4. Copper port status LED
11. Reset Button
5. Copper port status LED

6. Fiber port status LED

Long press PoE Mode Switch-Over Button for above 2 seconds to switch the display mode between PoE mode and
port rate mode.

Back Panel

Figure 1-11 Back Panel of RG-S2910-10GT2SFP-UP-H

Note:  Grounding pole  Air exhaust

 Air exhaust

Power Supply

The RG-S2910-10GT2SFP-UP-H switch adopts AC or HVDC power input.

 AC input

Rated voltage range: 100V to 240V

Maximum voltage range: 90V to 264V

Frequency range: 50/60 Hz

Rated current: 8A

Power cord specification: 10A

 HVDC input
Hardware Installation and Reference Guide Product Overview

Voltage range: 192V to 290V

Current range: 0A to 6A

Heat Dissipation

The RG-S2910-10GT2SFP-UP-H adopts turbine fans for heat dissipation, thereby ensuring normal function of the device
in the specified environment. 10 cm distance space should be reserved at both sides and both planes of the cabinet to
allow air circulation. It is recommended to clean the device once every 3 months to avoid dust from blocking vents. Figure
1-12 shows the flow scheme of heat dissipation.

Figure 1-12 Flow Scheme of Heat Dissipation

LEDs

LED Panel Identification State Meaning

Off The switch is not receiving power.

The system is being initialized.


Blinking green
Continuous blinking indicates errors.

Solid green The switch is operational.


System status LED Status

Temperature warning

Solid yellow Check the working environment of the switch


immediately.

Solid red The switch is faulty.


Hardware Installation and Reference Guide Product Overview

Solid green Indicates the switching state.


PoE status LED PoE
Solid yellow Indicates the PoE state.

Off The port is not connected.

Solid green The port is connected at 1000 Mbps.

The port is receiving or transmitting traffic at 1000


Blinking green
1000Mbps RJ-45 port 1-10 Mbps.
status LED
Solid yellow The port is connected at 10/100 Mbps.

The port is receiving or transmitting traffic at


Blinking yellow
10/100 Mbps.

Off PoE is not enabled.

RJ45 port PoE status


1-8 Solid green PoE is enabled. The port is operational.
LED

Solid yellow The PoE port is abnormally operational.

Off The port is not connected.

1000Mbps SFP port Solid green The port is connected at 1000 Mbps.
11F-12F
status LED
The port is receiving or transmitting traffic at 1000
Blinking green
Mbps.
Hardware Installation and Reference Guide Preparation before Installation

2 Preparation before Installation

2.1 Safety Suggestions

To avoid personal injury and equipment damage, please carefully read the safety suggestions before you install the
RG-S2910-H series switch.

The following safety suggestions do not cover all possible dangers.

2.1.1 Installation
 Keep the chassis clean and free from any dust.

 Do not place the equipment in a walking area.

 Do not wear loose clothes or accessories that may be hooked or caught by the device during installation and
maintenance.

 Turn off all power supplies and remove the power sockets and cables before installing or uninstalling the device.

2.1.2 Movement
 Do not frequently move the device.

 When moving the device, note the balance and avoid hurting legs and feet or straining the back.

 Before moving the device, turn off all power supplies and dismantle all power modules.

2.1.3 Electricity
 Observe local regulations and specifications when performing electric operations. Relevant operators must be
qualified.

 Before installing the device, carefully check any potential danger in the surroundings, such as ungrounded power
supply, and damp/wet ground or floor.

 Before installing the device, find out the location of the emergency power supply switch in the room. First cut off the
power supply in the case of an accident.

 Try to avoid maintaining the switch that is powered-on alone.

 Be sure to make a careful check before you shut down the power supply.

 Do not place the equipment in a damp location. Do not let any liquid enter the chassis.

Any nonstandard and inaccurate electric operation may cause an accident such as fire or electrical shock, thus
causing severe even fatal damages to human bodies and equipment.

Direct or indirect touch through a wet object on high-voltage and mains supply may bring a fatal danger.

If a power supply system is equipped with a leakage protector (also referred to as "leakage current switch" or
"leakage current breaker"), the rated leakage action current of each leakage protector is greater than twice of the
theoretical maximum leakage current of all the power supplies in the system. For example, if a system is equipped
Hardware Installation and Reference Guide Preparation before Installation

with sixteen identical power supplies, the leakage current of each power supply is equal to or less than 3.5mA, and
the leakage current of the system totals 56mA. A leakage protector with 30mA rated action current supports less
than five power supplies (that is, Action current of the leakage protector/2/Maximum leakage current of each power
supply =30/2/3.5≈4.28). In other words, the leakage protector with 30mA rated action current supports no more than
four power supplies. In this case, the sixteen power supplies in the system require at least four leakage protectors
with 30mA rated action current and each leakage protector supports four power supplies. If power supplies in a
system differ in models, the rated leakage action current of each leakage protector divided by two is greater than the
sum of maximum leakage current of all the power supplies. The rated leakage non-action current of a leakage
protector shall be 50% of the leakage action current. Take a leakage protector with 30mA rated leakage action
current as an example. The rated leakage non-action current shall be 15mA. When the leakage current is below
15mA, the protector shall not act. Otherwise, misoperation may easily occur due to high sensitivity and thus the
leakage protector trips, devices are powered off, and services are interrupted.

To guarantee personal safety, the rated leakage action current of each leakage protector in the system must be
equal to or less than 30mA (human body safety current is 30mA). When twice of the total leakage current of the
system is greater than 30mA, the system must be equipped with two or more leakage protectors.

For the leakage current value of each power supply model, see the power supply model parameter table in Chapter
1.

2.1.4 Static Discharge Damage Prevention


To prevent damage from static electricity, pay attention to the following:

 Proper grounding of grounding screws on the back panel of the device. Use of a three-wire single-phase socket with
protective earth wire (PE) as the AC power socket.

 Indoor dust prevention

 Proper humidity conditions

2.1.5 Laser
The RG-S2910-H series switch supports varying models of optical modules sold on the market which are Class I laser
products. Improper use of optical modules may cause damage. Therefore, pay attention to the following when you use
them:

 When a fiber transceiver works, ensure that the port has been connected with an optical fiber or is covered with a
dust cap, to keep out dust and avoid burning your eyes.

 When the optical module is working, do not pull out the fiber cable and stare into the transceiver interface or you may
hurt your eyes.

Do not stare into any optical port under any circumstances, as this may cause permanent damage to your eyes.

2.1.6 Storage Security


To ensure the normal operation of the device, maintain a proper storage environment in accordance with the storage
temperature/storage humidity requirements in the technical specifications table of the corresponding device.

If the storage time exceeds 18 months, you must power on the device and keep it running for 24 hours without
interruption for device activation.
Hardware Installation and Reference Guide Preparation before Installation

2.2 Installation Site Requirements

To ensure the normal working and a prolonged durable life of the equipment, the installation site must meet the following
requirements.

2.2.1 Ventilation
For the RG-S2910-H, a sufficient space (at least 10 cm distances from both sides and the back plane of the cabinet)
should be reserved at the ventilation openings to ensure the normal ventilation. After various cables have been connected,
they should be arranged into bundles or placed on the cabling rack to avoid blocking the air inlets. It is recommended to
clean the switch at regular intervals (like once every 3 months). Especially, avoid dust from blocking the screen mesh on
the back of the cabinet.

2.2.2 Temperature and Humidity


To ensure the normal operation and prolong the service life of RG-S2910-H series switch, you should keep proper
temperature and humidity in the equipment room.

If the equipment room has temperature and humidity that do not meet the requirements for a long time, the equipment
may be damaged.

 In an environment with high relative humidity, the insulating material may have bad insulation or even leak electricity.
Sometimes the materials may suffer from mechanical performance change and metallic parts may get rusted.

 In an environment with low relative humidity, however, the insulating strip may dry and shrink. Static electricity may
occur easily and endanger the circuit on the equipment.

 In an environment with high temperature, the equipment is subject to even greater harm, as its performance may
degrade significantly and various hardware faults may occur.

Therefore, the ambient temperature and humidity of the RG-S2910-H series must meet the requirements listed in Table
2-1:

Table 2-1 Temperature and Humidity Requirements of the RG-S2910-H Series Switch

Temperature Relative Humidity


0 ºC to 50ºC (32°F to 122°F) 10% to 90%

The requirements for the sampling site of the temperature and humidity in the operating environment of the device
are as follows:
There is no protective plate at the front or back of the equipment rack.
The vertical height is 1.5 m above the floor.
The distance from the front panel of the equipment is 0.4 m.

2.2.3 Cleanness
Dust poses a severe threat to the running of the equipment. The indoor dust falling on the equipment may be adhered by
the static electricity, causing bad contact of the metallic joint. Such electrostatic adherence may occur more easily when
the relative humidity is low, not only affecting the useful life of the equipment, but also causing communication faults.
Table 2-2 shows the requirements for the dust content and granularity in the equipment room.
Hardware Installation and Reference Guide Preparation before Installation

Table 2-2 Requirements for the Dust Content and Granularity in the Equipment Room

Dust Unit Density


Diameter≥0.5μm Particles/m3 ≤3.5×106
Diameter≥5μm Particles/m3 ≤3×104

Apart from dust, the salt, acid and sulfide in the air in the equipment room must also meet strict requirements, as such
poisonous substances may accelerate the corrosion of the metal and the aging of some parts. The equipment room
should be protected from the intrusion of harmful gases such as sulfur dioxide, sulfured hydrogen, nitrogen dioxide, and
chlorine), whose requirements are listed in Table 2-3.

Table 2-3 Requirements for Harmful Gases in the Equipment Room

Gas Average (mg/m3) Maximum (mg/m3)


SO2 0.3 1.0
H2 S 0.1 0.5
NO2 0.5 1.0
Cl2 0.1 0.3

Both average and maximum value are measured for a week. The switch cannot be placed in the environment with
the maximum density for over 30 minutes every day.

2.2.4 Grounding
A good grounding system is the basis for the stable and reliable operation of the RG-S2910-H series switch. It is the chief
condition to prevent lightning stroke and resist interference. Please carefully check the grounding conditions on the
installation site according to the grounding requirements, and perform grounding operations properly as required.

Effective grounding of the switch is an important guarantee for lightning protection and interference resistance.
Therefore, connect the grounding line of the switch properly.

Safety Grounding

The equipment using AC power supply must be grounded by using the yellow/green safety grounding cable. Otherwise,
when the insulating resistance decreases the power supply and the enclosure in the equipment, electric shock may occur.

The building must provide protective grounding connection to ensure that the device is connected to the protection
location.

The installation and maintenance personnel must check whether the A.C. socket is well connected to the protection
location of the building, if not, they should use a protective grounding wire to connect the grounding end of the A.C.
socket to the building's protection location.

Power cords should be connected to a grounded output socket.

The power supply socket must be installed in a place that is near to the device and where users can operate the
device easily.

Before the installation of the device, make sure that ground connection is connected at first and disconnected finally.

The sectional area of the protective grounding wire should be at least 1 mm2 (16 AWG).

Use the 3-core power supply line. The sectional area of each pin should be at least 1 mm2 or 16 AWG.

Lightning Grounding
Hardware Installation and Reference Guide Preparation before Installation

The lightning protection system of a facility is an independent system that consists of the lightning rod, download
conductor and the connector to the grounding system, which usually shares the power reference ground and yellow/green
safety cable ground. The lightning discharge ground is for the facility only, irrelevant to the equipment.

EMC Grounding

The grounding required for EMC design includes shielding ground, filter ground, noise and interference suppression, and
level reference. All the above constitute the comprehensive grounding requirements. The resistance of earth wires should
be less than 1 ohm. The RG-S2910-H series switch back plane is reserved with one grounding pole, as shown in Figure
2-1.

Figure 2-1Grounding of RG-S2910-H

2.2.5 Lightning Resistance


When the AC power cable is imported outdoors and directly connected to the power port of the RG-S2910-H series switch,
lightning line bank should be adopted to prevent the switch from being hit by lightning shocks. Usage of the lightning line
bank: Connect the mains supply AC cable to the lightning line bank. Then, connect the switch to the lightning line bank.
This can help to prevent the current of high-voltage lightning from passing the switch directly through the mains supply
cable to a certain extent.

The lightning line banks are not provided and should be purchased by users as required.
For the usage of lightning line banks, refer to their related manuals.

2.2.6 EMI
Electro-Magnetic Interference (EMI), from either outside or inside the equipment or application system, affects the system
in the conductive ways such as capacitive coupling, inductive coupling, and electromagnetic radiation.

There are two types of electromagnetic interference: radiated interference and conducted interference, depending on the
type of the transmission path.

When the energy, often RF energy, from a component arrives at a sensitive component via the space, the energy is
known as radiated interference. The interference source can be either a part of the interfered system or a completely
electrically isolated unit. Conducted interference results from the electromagnetic wire or signal cable connection between
the source and the sensitive component, along which cable the interference conducts from one unit to another. Conducted
interference often affects the power supply of the equipment, but can be controlled by a filter. Radiated interference may
affect any signal path in the equipment and is difficult to shield.

 For the AC power supply system TN, single-phase three-core power socket with protective earthing conductors (PE)
should be adopted to effectively filter out interference from the power grid through the filtering circuit.
Hardware Installation and Reference Guide Preparation before Installation

 The grounding device of the switch must not be used as the grounding device of the electrical equipment or
anti-lightning grounding device. In addition, the grounding device of the switch must be deployed far away from the
grounding device of the electrical equipment and anti-lightning grounding device.

 Keep the equipment away from high-power radio transmitter, radar transmitting station, and high-frequency
large-current device.

 Measures must be taken to shield static electricity.

 Interface cables should be laid inside the equipment room. Outdoor cabling is prohibited, avoiding damages to
device signal interfaces caused by over-voltage or over-current of lightning.

2.3 Requirements of Installation Tools

Table 2-4 List of Installation Tools

Phillips screwdriver, flathead screwdriver, related electric cables and optical cables, bolts, diagonal
Common Tools
pliers, straps
Special Tools Anti-static tools
Meters Multimeter

The tool kit is customer-supplied.


Hardware Installation and Reference Guide Product Installation

3 Product Installation
Please ensure that you have carefully read Chapter 2.
Make sure that the requirements set forth in Chapter 2 have been met.

3.1 Installation Flowchart

3.2 Confirmations before Installation

Before installation, please confirm the following points:

 Whether ventilation requirements are met for the switch

 Whether the requirements of temperature and humidity are met for the switch

 Whether power cables are already laid out and whether the requirements of electrical current are met

 Whether related network adaption lines are already laid out

3.3 Installing the RG-S2910-H

Precautions

During installation, note the following points:


Hardware Installation and Reference Guide Product Installation

 Connect the power cables of different colors to the corresponding grounding posts.

 Ensure that the interface of the power supply cable is well connected to the power interface of the device. The power
cables must be protected using power cable retention clips after they are connected to the device.

 Do not place any articles on the RG-S2910-H series switch.

 Reserve a spacing of at least 10 cm around the chassis for good ventilation. Do not stack the devices.

 The switch should be located at places free from the large power radio launch pad, radar launch pad, and
high-frequency large-current devices. If necessary, electromagnetic shielding should be adopted. For example, use
interface cables to shield cables.

 100-meter network cables should be laid inside the equipment room and outdoor cabling of such cables is prohibited.
If outdoor cabling is necessary, take relevant measures for lightning protection.

3.3.1 Mounting the Switch to a Standard 19-inch Rack


The RG-S2910-H series switches follow the EIA standard dimensions and can be installed in 19-inch distribution cabinets.

Attach the mounting brackets to the switch with the supplied screws, as shown in Figure 3-1.

Figure 3-1 Attaching the Mounting Bracket to the Switch

Align the mounting holes in the mounting bracket with the mounting holes in the rack, as shown in Figure 3-2.

Figure 3-2
Hardware Installation and Reference Guide Product Installation

Use the supplied M6 screws and cage nuts to securely attach the mounting brackets to the rack, as shown in Figure 3-3.

Figure 3-3

3.3.2 Mounting the Switch on a Table


Attach the four rubber feet to the recessed areas on the bottom of the switch, as shown in Figure 3-4.

Figure 3-4 Attaching the Rubber Feet to the Recessed Areas

Place the switch on the table, as shown in Figure 3-5.

Figure 3-5 Mounting the Switch on the Table


Hardware Installation and Reference Guide Product Installation

The device must be installed and operated in the place that can restrict its movement.

3.4 Checking after Installation

Before checking the installation, switch off the power supply so as to avoid any personal injury or damage to the
component due to connection errors.

 Check that the ground line is connected.

 Check that the cables and power input cables are correctly connected.

 Check that all interface cables are laid out inside the equipment room. In the case of external cabling, check that the
lightning resistance socket or network interface lightning protector is connected.

 Check that sufficient airflow is available around the device (over 10 cm)
Hardware Installation and Reference Guide System Debugging

4 System Debugging

4.1 Establishing the Debugging Environment

Establishing the Debugging Environment

Connect the PC to the console port of the switch through the console cable, as shown in Figure 4-1.

Figure 4-1 Schematic Diagram of the Configuration Environment

Connecting the Console Cable

 Step 1: Connect the end of the console cable with DB-9 jack to the serial port of the PC.

 Step 2: Connect the end of the console cable with RJ45 to the console port of the switch.

Setting HeperTerminal Parameters

 Step 1: Start the PC and run the terminal simulation program on the PC, such as Terminal on Windows 3.1 or
HyperTerminal on Windows 95/98/NT/2000/XP.

 Step 2: Set terminal parameters. The parameters are as follows: baud rate 9600, data bit 8, parity check none, stop
bit 1, and flow control as none.

1. Choose Setup>Program>Attachment >Communication> Hyper Terminal.


2. Choose Cancel, the interface as shown in figure 4-2 is displayed.

Figure 4-2
Hardware Installation and Reference Guide System Debugging

3. Enter the name of the new connection and click OK, the interface as shown in Figure 4-3 is displayed. Choose the
serial port used currently in the column [use when connecting].

Figure 4-3

4. After choosing the serial port, click OK to display the serial port parameter setting interface, set the baud rate to 9600,
data bit to 8, parity check to none, stop bit to 1 and flow control to none.

Figure 4-4
Hardware Installation and Reference Guide System Debugging

5. After setting the parameters, click OK to enter the hyper terminal interface.

4.2 Startup Check

4.2.1 Checking before the Device is Powered on


 The switch is fully grounded.

 The power cable is correctly connected.

 The power supply voltage complies with the requirement of the switch.

 The control cable of the PC is properly connected to the console port of the switch. The HyperTerminal is started and
the parameter settings are correct.

4.2.2 Checking after Program Startup (Recommended)


After power-on, you are recommended to perform the following checks to ensure the normal operation of follow-up
configurations.

 Check whether information is displayed on the terminal interface.

 Check whether the status of the switch indicator is normal.

 Check whether the main program of the device is normally loaded.

 Check whether the time on the device is consistent with the current Beijing time.
Hardware Installation and Reference Guide System Debugging

 Check whether the service interface forwards data normally.


Hardware Installation and Reference Guide Maintenance and Troubleshooting

5 Maintenance and Troubleshooting

5.1 General Troubleshooting Procedure

5.2 Troubleshooting Common Faults

Symptom Possible Causes Solution


Forgetting the
A password is manually configured but Please contact Ruijie Networks Customer Service
management interface
it is forgotten. Department for technical support.
login password
The status indicator is The power supply module does not Check whether the power socket at the equipment
not on after the switch supply power. room is normal and whether the power cable of the
is started. The power cable is in loose contact. switch is in good contact.
Check whether the fan stops working or is
damaged.
The status indicator is Fan alarm Temperature alarm: the switch already stops the
red. Temperature alarm normal service exchanges. Check in time the
working environment of the switch, clean the dust
on the cabinet and reinforce the refrigeration effect.
The serial port The serial port connected to the switch Change the serial port opened by the configuration
console has no output does not match that opened by the software to be the one connected to the switch.
Hardware Installation and Reference Guide Maintenance and Troubleshooting

or outputs illegible configuration software. Check that the parameter configuration of the serial
characters. The serial port is not configured port matches that specified in the instructions.
correctly.
The connected twisted pair cable is
The RJ45 port is not in
faulty.
connectivity or it is Replace the twisted pair cable.
The length of the cable exceeds 100 m.
erroneous in Check that the port configuration has the common
The port has special configuration that
receiving/transmitting working mode with the connected switch.
has no common working mode with the
frames.
connected switch.
The Rx and Tx ends are connected Switch the Rx and Tx ends of the optical fiber.
reversely. Replace the optical module with one of the
The interconnected optical module type matched type.
The fiber port cannot
does not match. Replace the optical fiber with one of the
be connected.
The fiber type is not correct. appropriate type.
The length of the optical fiber exceeds Replace the optical fiber with one of the
that rated of the optical module. appropriate length.
Hardware Installation and Reference Guide Appendix A: Connectors and Connection Media

Appendix A: Connectors and Connection Media


1000BASE-T/100BASE-TX/10BASE-T Ports

The 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX
Crossover at these three rates.

The 1000BASE-T complies with IEEE 802.3ab, and uses the cable of 100-ohm Category-5 or Supper Category-5 UTP or
STP, which can be up to 100 m.

The 1000BASE-T port uses four pairs of wires for transmission, all of which must be connected. Figure A-1 shows the
connections of the twisted pairs used by the 1000BASE-T port.

Figure A-1 Four Twisted Pairs of the 1000BASE-T

In addition to the above cables, the 100BASE-TX/10BASE-T can also use 100-ohm Category-3, 4, 5 cables for 10 Mbps,
and 100-ohm Category-5 cables for 100 Mbps, both of which can be up to 100 m. Figure A-2 shows the pinouts of the
100BASE-TX/10BASE-T.

Figure A-2 Pinouts of the 100BASE-TX/10BASE-T

Figure A-3 shows the straight-through and crossover cable connections for the 100BASE-TX/10BASE-T.

Figure A-3 Connections of the Twisted Pairs of the 100BASE-TX/10BASE-T


Hardware Installation and Reference Guide Appendix A: Connectors and Connection Media

Optical Fiber Connection

For the optical fiber ports, select single-mode or multiple-mode optical fibers for connection according to the fiber module
connected. The connection schematic diagram is shown in Figure A-4:

Figure A-4 Optical Fiber Connections


Hardware Installation and Reference Guide Appendix B: Mini-GBIC and SPF+ Module

Appendix B: Mini-GBIC and SPF+ Module


SFP modules (Mini-GBIC module) and 10G SFP+ modules are available to address the requirements of interface types of
switch modules. You can select the Mini-GBIC module to suit your specific needs. The models and technical
specifications of some Mini-GBIC and 10G SFP+ modules are listed below. For details, see Ruijie Transceiver Installation
and Reference Guide.

Table B-1 Models and Technical Specifications of the 1000M Mini-GBIC(SFP) Module

Intensity of
DDM Intensity of Received
Wave Length Media Transmitted Light
Model (Yes/ Light (dBm)
(nm) Type (dBm)
No)
Min Max Min Max

MINI-GBIC-SX-MM850 850 MMF No -9.5 -3 -17 0

MINI-GBIC-LX-SM1310 1310 SMF No -9.5 -3 -20 -3

GE-SFP-SX 850 MMF No -9.5 -3 -17 0

GE-SFP-LX 1310 SMF No -9.5 -3 -20 -3

GE-SFP-SX-SM1550-BIDI 1550TX/1310RX MMF No -10 -5 -17 -3

GE-SFP-SX-SM1310-BIDI 1310TX/1550RX MMF No -10 -5 -17 -3

GE-eSFP-SX-MM850 850 MMF Yes -9.5 -3 -17 0

GE-eSFP-LX-SM1310 1310 SMF Yes -9.5 -3 -20 -3

GE-SFP-LX-SM1310 1310 SMF No -9.5 -3 -20 -3

GE-SFP-LX20-SM1310-BIDI 1310TX/1550RX SMF Yes -9 -3 -20 -3

GE-SFP-LX20-SM1550-BIDI 1550TX/1310RX SMF Yes -9 -3 -20 -3

GE-SFP-LH40-SM1310-BIDI 1310TX/1550RX SMF Yes -5 0 -24 -1

GE-SFP-LH40-SM1550-BIDI 1550TX/1310RX SMF Yes -5 0 -24 -1

MINI-GBIC-LH40-SM1310 1310 SMF Yes -2 3 -22 -3

MINI-GBIC-ZX50-SM1550 1550 SMF Yes -5 0 -22 -3

MINI-GBIC-ZX80-SM1550 1550 SMF Yes 0 4.7 -22 -3

MINI-GBIC-ZX100-SM1550 1550 SMF Yes 0 5 -30 -9

Table B-2 Models of 1000M SFP Copper Module

Standard Model DDM (Yes/No)


1000Base-T Mini-GBIC-GT No

Table B-3 Module Cabling Specification


Interface
Model Fiber Type Core Size(μm) Cable Distance (Max.)
Type
MINI-GBIC-SX-MM850 LC MMF 62.5/125 275m
Hardware Installation and Reference Guide Appendix B: Mini-GBIC and SPF+ Module

50/125 550m
MINI-GBIC-LX-SM1310 LC SMF 9/125 10km
GE-eSFP-SX-MM850 LC 62.5/125 275m
MMF
50/125 550m
GE-eSFP-LX-SM1310 LC SMF 9/125 10km
GE-SFP-LX-SM1310 LC SMF 9/125 10km
MINI-GBIC-LH40-SM1310 LC SMF 9/125 40km
GE-SFP-SX-SM1310-BIDI LC MMF 50/125 500m
GE-SFP-SX-SM1550-BIDI LC MMF 50/125 500m
GE-SFP-LX20-SM1310-BIDI LC SMF 9/125 20km
GE-SFP-LX20-SM1550-BIDI LC SMF 9/125 20km
GE-SFP-LH40-SM1310-BIDI LC SMF 9/125 40km
GE-SFP-LH40-SM1550-BIDI LC SMF 9/125 40km
MINI-GBIC-ZX50-SM1550 LC SMF 9/125 50km
MINI-GBIC-ZX80-SM1550 LC SMF 9/125 80km
MINI-GBIC-ZX100-SM1550 LC SMF 9/125 100km
SDH155-SFP-SX-MM850 LC MMF 62.5/125 500m
SDH155-SFP-SX-MM1310 LC MMF 62.5/125 2km
SDH155-SFP-LH15-SM1310 LC SMF 9/125 15km
SDH155-SFP-LH40-SM1310 LC SMF 9/125 40km
SDH155-SFP-LH80-SM1310 LC SMF 9/125 80km
GE-SFP-SX 62.5/125 275m
LC MMF
50/125 550m
GE-SFP-LX LC SMF 9/125 10km
Mini-GBIC-GT RJ45 Category 5 (or above ) UTP or STP 100m

For the optical module with transmission distance exceeding 40 km and more, one on-line optical attenuator should
be added on the link to avoid the overload of the optical receiver when short single-mode optical fibers are used.

Optical modules generate laser. Do not stare at light source.

To keep optical modules clean, please use dust caps when the modules are not connected with fibers.

Table B-4 Models and Technical Specifications of 2.5G SFP Cable Module
Support DDM
Model Module Type Connector Length(m) Data Rate(Gb/s)
(Yes/No)
GE-SFP-STACK1.6M Passive SFP 1.6 3.125 No

No extra cables are needed when SFP cables are used. Inserting the two ends of a SFP cable into corresponding
ports facilitates inter-communication between the two ports.

Table B-5 Models and Specifications of 10G SFP+ Modules

Model Wave Length Media DDM Intensity of Intensity of Received


Hardware Installation and Reference Guide Appendix B: Mini-GBIC and SPF+ Module

(nm) Type (Yes/ Transmitted Light Light (dBm)


No) (dBm)

Min Max Min Max

XG-SFP-SR-MM850 850 MMF Yes -5 -1 -7.5 0.5

XG-SFP-SR-SM1270-BIDI 1270 MMF No -3 4 -9 0.5

XG-SFP-SR-SM1330-BIDI 1270 MMF No -3 4 -9 0.5

XG-SFP-LR-SM1270-BIDI 1270 SMF No -6.5 0.5 -14.4 0.5

XG-SFP-LR-SM1330-BIDI 1330 SMF No -6.5 0.5 -14.4 0.5

XG-SFP-LR-SM1310 1310 SMF Yes -8.2 0.5 -14.4 0.5

XG-SFP-ER-SM1550 1550 SMF Yes -4.7 4 -11.3 -1

XG-SFP-ZR-SM1550 1550 SMF Yes 0 4 -24 -7

XS-SFP-SR 850 MMF Yes -5 -1 -7.5 0.5

XS-SFP-LR 1310 SMF Yes -8.2 0.5 -10.3 0.5

Table B-6 SFP+ Module Cabling Specification


Modular Cable
Interface
Model Fiber Type Core Size(μm) Bandwidth Distance
Type
(MHz/km) (Max.)
200(OM1) 33m
62.5/125
160 26m
XG-SFP-SR-MM850 LC MMF 2000(OM3) 300m
50/125 500(OM2) 82m
400(OM1) 66m
XG-SFP-SR-SM1270-BIDI LC MMF 50/125 2000(OM3) 300m
XG-SFP-SR-SM1330-BIDI LC MMF 50/125 2000(OM3) 300m
XG-SFP-LR-SM1270-BIDI LC SMF 9/125 N/A 10km
XG-SFP-LR-SM1330-BIDI LC SMF 9/125 N/A 10km
XG-SFP-LR-SM1310 LC SMF 9/125 N/A 10km
XG-SFP-ER-SM1550 LC SMF 9/125 N/A 40km
XG-SFP-ZR-SM1550 LC SMF 9/125 N/A 80km
LC 200(OM1) 33m
62.5 /125
160 26m
XS-SFP-SR MMF 2000(OM3) 300m
50/125 500(OM2) 82m
400(OM1) 66m
XS-SFP-LR LC SMF 9/125 N/A 10km

For XG-SFP-ER-SM1550 and XG-SFP-ZR-SM1550, please do not use short-distance fibers for connection to avoid
the overload of the transceiver. If optical power on the receiving end is not lower than -1dBm, a proper optical
attenuator is supposed to be installed onto the end so as to reduce the optical power to lower than -1dBM.
Hardware Installation and Reference Guide Appendix B: Mini-GBIC and SPF+ Module

Optical modules generate laser. Do not stare at light source.

To keep optical modules clean, please use dust caps when the modules are not connected with fibers.

Table B-7 Models and Specifications of Existing 10G SFP+ Cable Modules
Conductor Wire Support
Module
Model Connector Length(m) Diameter (AWG) Data Rate(Gb/s) DDM
Type
(Yes/No)
XG-SFP-CU1M Passive SFP+ 1 28 10.3125 No
XG-SFP-CU3M Passive SFP+ 3 28 10.3125 No
XG-SFP-CU5M Passive SFP+ 5 26 10.3125 No
XG-SFP-AOC1M Active SFP+ 1 \ 10.3125 No
XG-SFP-AOC3M Active SFP+ 3 \ 10.3125 No
XG-SFP-AOC5M Active SFP+ 5 \ 10.3125 No

No extra cables are needed when SFP cables are used. Inserting the two ends of a SFP cable into corresponding
ports facilitates inter-communication between the two ports.

Table B-8 Specifications of SFP BIDI Optical Module Pairs

Rate/Distance Module Pairs


GE-SFP-SX-SM1310-BIDI
1000M/500m
GE-SFP-SX-SM1550-BIDI
GE-SFP-LX20-SM1310-BIDI
1000M /20km
GE-SFP-LX20-SM1550-BIDI
GE-SFP-LH40-SM1310-BIDI
100M/40km
GE-SFP-LH40-SM1550-BIDI
XG-SFP-SR-SM1270-BIDI
10G /300m
XG-SFP-SR-SM1330-BIDI
XG-SFP-LR-SM1270-BIDI
10G /10km
XG-SFP-LR-SM1330-BIDI

The BIDI modules must be used in pairs (e.g., FE-SFP-LX20-SM1310-BIDI and FE-SFP-LX20-SM1550-BIDI).
Hardware Installation and Reference Guide Appendix C: Lightning Protection

Appendix C: Lightning Protection


Installing AC Power Arrester (lightning protection cable row)

The external lightning protection cable row shall be used on the AC power port to prevent the switch from being struck by
lightning when the AC power cable is introduced from the outdoor and directly connected to the power port of the switch.
The lightning protection cable row is fixed on the cabinet, operating table or the wall in the machine room using the line
buttons and screws.

Figure C-1 Schematic Diagram for the Power Arrester

The power arrester is not provided and the user shall purchase it to address the practical requirement.

Precautions for installation:

 Make sure that the PE terminal of the power arrester has been well-grounded;

 After connecting the switch AC power plug to the socket of the power arrester (lightning protection cable row),
lightning protection function implements if the RUN LED is Green and the ALARM LED is OFF.

 If the ALARM LED on the power arrester is Red, you shall check what the reason is, poor grounding connection or
the reversed connection of the Null and Live lines: Use the multimeter to check the polarity of the power socket for
the arrester when the LED is Red, if the N line is on the left and the L line is on the right, the arrester PE terminal is
not grounded; if the L line is on the left and the N line is on the right, the polarity of the arrester power cable shall be
reversed; if the LED is still Red, it is confirmed that the arrester PE terminal has not been grounded.

Installing the Ethernet Port Arrester


Hardware Installation and Reference Guide Appendix C: Lightning Protection

During the switch usage, the Ethernet port arrester shall be connected to the switch to prevent the switch damage by
lightning before the outdoor network cable connects to the switch.

Tools: Cross or straight screwdriver, Multimeter, Diagonal pliers

Installation Steps:

1. Tear one side of the protection paper for the double-sided adhesive tape and paste the tape to the framework of the
Ethernet port arrester. Tear the other side of the protection paper for the double-sided adhesive tape and paste the
Ethernet port arrester to the switch framework. The paste location for the Ethernet port arrester shall be as close to
the grounding terminal of the switch.
2. Based on the distance of the switch grounding terminal, cut the grounding line for the Ethernet port arrester and firmly
tighten the grounding line to the grounding terminal of the switch.
3. Use the multimeter to check whether the grounding line for the arrester is in good contact with the switch grounding
terminal and the framework.
4. According to the description on the Ethernet Port Arrester Hardware Installation Guide, connect the arrester using the
adapter cable(note that the external network cable is connected to the end of IN, while the adapter cable connected to the
switch is connected to the end of OUT) and observe whether the LED on the board is normal or not.
5. Use the nylon button to bundle the power cables.

Figure C-2 Schematic Diagram for the Ethernet port Arrester Installation

The Ethernet port arrester is only for the 10M/100M copper Ethernet ports with the RJ-45 connector;

The Ethernet port arrester is not provided, the user can purchase them to address their own practical requirements.
For the detailed information during the arrester installation, please refer to Ethernet Port Arrester Hardware
Installation Guide, which contains the technical specification and the maintenance and installation of the arrester.

You may pay attention to the following conditions during the actual installation to avoid influencing the performance of the
Ethernet port arrester:
Hardware Installation and Reference Guide Appendix C: Lightning Protection

 Reversed direction of the arrester installation. You shall connect the external network cable to the “IN” end and
connect the switch Ethernet port to the “OUT” end.

 Poor arrester grounding. The length of the grounding line should be as short as possible to ensure that it is in good
contact with the switch grounding terminal. Use the multimeter to confirm the contact condition after the grounding.

 Incomplete arrester installation. If there is more than one port connected to the peer device on the switch, it needs to
install the arresters on all connection ports for the purpose of the lightning protection.
Hardware Installation and Reference Guide Appendix D: Cabling Recommendations in Installation

Appendix D: Cabling Recommendations in Installation


When RG-S2910-H series switches are installed in standard 19-inch cabinets, the cables are tied in the binding rack on
the cabinet by the cabling rack, and top cabling or bottom cabling is adopted according to the actual situation in the
equipment room. All cable connectors should be placed at the bottom of the cabinet in an orderly manner instead of
outside the cabinet easy to touch. Power cables are routed beside the cabinet, and top cabling or bottom cabling is
adopted according to the actual situation in the equipment room, such as the position of the DC power distribution box, AC
socket, or lightning protection box.

Requirement for the minimum cable bend radius

 The bend radius of a power cord, communication cable, and flat cable should be greater than five times their
respective diameters. The bend radius of these cables that often bend or suffer removal/insertion should be greater
than seven times their respective diameters.

 The bend radius of a common coaxial cable should be greater than seven times its diameter. The bend radius of this
type of cables that often bend or suffer removal/insertion should be greater than 10 times its diameter.

 The bend radius of a high-speed cable (SFP cable, for example) should be greater than five times its diameter. The
bend radius of this type of cables that often bend or suffer removal/insertion should be greater than 10 times its
diameter.

Requirement for the minimum fiber bend radius

 The diameter of a fiber tray to hold fibers cannot be less than 25 times the diameter of the fiber.

 When moving an optical fiber, the bend radius of the fiber should be equal to or greater than 20 times the diameter of
the fiber.

 During cabling of an optical fiber, the bend radius of the fiber should be equal to or greater than 10 times the
diameter of the fiber.

Precautions for Bundling up Cables

 Before bundling cables, correctly mark labels and stick the labels to cables where appropriate.

 Cables should be neatly and properly bundled, as shown in Figure D-1.

Figure D-1 Bundling Up Cables (1)


Hardware Installation and Reference Guide Appendix D: Cabling Recommendations in Installation

 Cables of different types (such as power cords, signal cables, and grounding cables) should be separated in cabling
and bundling. When they are close, crossover cabling can be adopted. In the case of parallel cabling, power cords
and signal cables should maintain a space equal to or greater than 30 mm.

 The binding rack and cabling slot inside and outside the cabinet should be smooth, without sharp corners.

 The metal hole traversed by cables should have a smooth and fully rounding surface or an insulated lining.

 Proper buckles should be selected to bundle up cables. It is forbidden to connect two or more buckles to bundle up
cables.

 After bundling up cables with buckles, you should cut off the remaining part. The cut should be smooth and trim,
without sharp corners, as shown in Figure D-2.

Figure D-2 Bundling Up Cables (2)

 When cables need to bend, you should first bundle them up. However, the buckle cannot be bundled within the bend
area. Otherwise, significant stress may be generated in cables, breaking cable cores. As shown in Figure D-3.
Hardware Installation and Reference Guide Appendix D: Cabling Recommendations in Installation

Figure D-3 Bundling Up Cables (3)

 Cables not to be assembled or remaining parts of cables should be folded and placed in a proper position of the
cabinet or cabling slot. The proper position indicates a position that will not affect device running or cause device
damage or cable damage during commissioning.

 The power cords cannot be bundled on the guide rails of moving parts.

 The power cables connecting moving parts such as door grounding wires should be reserved with some access after
assembled. When the moving part reaches the installation position, the remaining part should not touch heat sources,
sharp corners, or sharp edges. If heat sources cannot be avoided, high-temperature cables should be used.

 When using screw threads to fasten cable terminals, the bolt or screw must be tightly fastened, and anti-loosening
measures should be taken, as shown in Figure D-4.

Figure D-4 Cable Fastening


Hardware Installation and Reference Guide Appendix D: Cabling Recommendations in Installation

 The hard power cable should be fastened by the terminal connection area to prevent stress.

 Do not use self-tapping screws to fasten terminals.

 Power cables of the same type and in the same cabling direction should be bundled up into cable bunches, with
cables in cable bunches clean and straight.

 Binding by using buckles should be performed according to Table D-1.

Cable Bunch Diameter (mm) Binding Space (mm)

10 80-150

10-30 150-200

30 200-300

 No knot is allowed in cabling or bundling.

 For solder-less terminal blocks (such as air switches) of the cold pressing terminal type, the metal part of the cold
pressing terminal should not be exposed outside the terminal block when assembled
Hardware Installation and Reference Guide Appendix E: Site Selection

Appendix E: Site Selection


 The machine room should be at least 5km away from the heavy pollution source such as the smelter, coal mine and
thermal power plant, 3.7km away from the medium pollution source such as the chemical industry, rubber industry
and electroplating industry, and 2km away from the light pollution source such as the food manufacturer and leather
plant. If the pollution source is unavoidable, the machine room should be located on the windward side of the
pollution source perennially with advanced protection.

 The machine room should be at least 3.7km away from the sea or salt lake. Otherwise, the machine room must be
sealed, with air conditioner installed for temperature control. Saline soil cannot be used for construction. Otherwise,
you should select devices with advanced protection against severe environment.

 Do not build the machine room in the proximity of livestock farms. Otherwise, the machine room should be located
on the windward side of the pollution source perennially. The previous livestock house or fertilizer warehouse cannot
be used as the machine room.

 The machine room should be firm enough to withstand severe weather conditions such as windstorm and heavy rain
as well as away from dust. If the dust is unavoidable, keep the door and window away from the pollution source.

 The machine room should be away from the residential area. Otherwise, the machine room should meet the
construction standard in terms of noise.

 Make sure the air vent of the machine room is away from the sewage pipe, septic tank, and sewage treatment tank.
Keep the machine room under positive pressure to prevent corrosive gas from entering the machine room to corrode
components and circuit boards. Keep the machine room away from industrial boiler and heating boiler.

 The machine room had better be on the second floor or above. Otherwise, the machine room floor should be 600mm
higher than the highest flood level ever recorded.

 Make sure there are no cracks or holes in the wall and floor. If there are cable entries in the wall or window, take
proper sealing measures. Ensure that the wall is flat, wear-resistant, and dust-free, which should be up to the
standard for flame retarding, soundproofing, heat absorption, dust reduction, and electromagnetic shielding.

 Keep the door and the window closed to make the machine room sealed.

 The steel door is recommended for soundproofing.

 Sulfur-containing materials are forbidden.

 Pay attention to the location of the air conditioner. Keep the air conditioner from blowing wind straight toward the
device or blowing water drops from the window or air vent toward the device.

You might also like