0% found this document useful (0 votes)
81 views

SVT Cable

This document provides specifications for portable cordage and power cables. It describes the construction as having stranded copper conductors with bare copper insulation and PVC jacketing. The cables are rated for temperatures of 60 or 105 degrees Celsius and voltages up to 300V. Technical data is provided for 6 cable part numbers ranging from 16 to 18 AWG with 2 or 3 conductors. Specifications include insulation thickness, jacket thickness, diameter, ampacity, and weight.

Uploaded by

two traveller
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views

SVT Cable

This document provides specifications for portable cordage and power cables. It describes the construction as having stranded copper conductors with bare copper insulation and PVC jacketing. The cables are rated for temperatures of 60 or 105 degrees Celsius and voltages up to 300V. Technical data is provided for 6 cable part numbers ranging from 16 to 18 AWG with 2 or 3 conductors. Specifications include insulation thickness, jacket thickness, diameter, ampacity, and weight.

Uploaded by

two traveller
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Portable Cordage & Power Cable

SVT
Construction: Conductors: Stranded Copper Conductors 18-16 AWG.
Insulation: Bare Copper Conductors.
Jacket: PVC.
Applications:
Floor care appliances, household food preparing machines, lamps, clocks, fans, blowers,
home entertainment appliances, etc.

Technical Data:
Temperature: Rated Voltage: Color Code: Approvals:
60º or 105ºC 300V N/A UL spec No. 62,
E47523,
CSA Spec. C22.2,
No.49,
LL26332,
E217598

Part Size (AWG) No. Of. No. Of. Insulation Thickness Jacket Thickness Overall Diameter Ampacity Net Weight
Number Conds. Strands (Amperes)
(mm) (in) (mm) (in) (mm) (in) (kg/km) (lbs/Mft.)

SVT-18/2-X 18 2 41 0.38 0.015 0.76 0.030 6.10 0.240 10 47 31

SVT-18/3-X 18 3 41 0.38 0.015 0.76 0.030 6.48 0.255 10 56 38

SVT-17/2-X 17 2 52 0.38 0.015 0.76 0.030 6.15 0.242 10 53 36

SVT-17/3-X 17 3 52 0.38 0.015 0.76 0.030 7.11 0.280 10 62 42

SVT-16/2-X 16 2 65 0.38 0.015 0.76 0.030 7.11 0.280 13 55 37

SVT-16/3-X 16 3 65 0.38 0.015 0.76 0.030 7.37 0.290 13 71 48