MSDS SIG Portland Cement Type I
MSDS SIG Portland Cement Type I
for
PORTLAND CEMENT TYPE I
VERSION 1.0
PRODUCT IDENTIFICATION
Trade name : Portland Cement Type I
Synonyms / other names : Portland Cement Type I (ASTM C150, SNI 2049)
Intended Use of Product : Portland cement Type I is used as a binder in combination
with water and aggregates to form concrete. It is also used
as a component of masonry mortar and other building and
construction materials.
UN number : None Allocated
Dangerous goods class and : None Allocated
Subsidiary risk
Hazchem code : None Allocated
Poisons schedule number : None Allocated
Formula : Mixture-None Allocated
Chemical Abstract Service : Mixture-None Allocated ( CAS )
MANUFACTURER IDENTIFICATION
Company : PT. Semen Indonesia (Persero) Tbk.
South Quarter, Tower A 19-20th Floor
Jl. R.A. Kartini Kav. 8, Cilandak Barat
Jakarta Selatan 12430, Indonesia
ContactforInformation : Semen Indonesia Customer Care
TollFree : 0 800 10 88888
Office Phone : 62-21-5261174-5
Fax : 62-21-5261176
Website : https://sig.id/id/
Email : [email protected]
page 1 of 8
Label Elements :
Hazard Pictograms (GHS US)
Other Components
page 2 of 8
Cement is made from materials mined from the earth and processed using energy provided by fuels.
Additional materials, such as pozzolan may also be introduced into the cement manufacturing
process. A chemical analysis of cement may reveal trace amounts of naturally occurring but
potentially harmful chemical compounds such as silica (quartz), potassium and sodium compounds.
Other trace constituents may include calcium oxide (also known as free lime or quick lime) and
compounds from grinding aids.
page 3 of 8
SECTION V – FIRE FIGHTING MEASURES
Safe Handling Practices : Avoid contact with skin or eyes. Avoid breathing dust. Use only in
well ventilated areas. Wear appropriate personal protective
equipment to prevent eye or skin contact and use respiratory
protection equipment if dusty or in poorly ventilated areas.
Safe Storage Measures : Store in well-ventilated areas away from moisture and
incompatible materials. If stored in containers, keep containers
closed when not in use.
Incompatible Materials : Water/moisture exposure will cause material to generate heat.
Keep away from fluoride compounds, strong acids, alkalines, and
oxidizers. Cement dissolves in hydrofluoric acid, producing
corrosive silicon tetrafluoride gas.
Exposure Limits for Individual Components (T= Total Respirable [PNOC/PNOR], R=Respirable fraction, I=Inhalable-
aerosol)
Component OSHA PEL ACGIH TLV NIOSH REL
Cement, Portland 15 mg/m3 (T); 5 mg/m3 (R) 10 mg/m3 (R) 10 mg/m3 (T); 5 mg/m3 (R)
Gypsum (Calcium Sulfate) 15 mg/m3 (T); 5 mg/m3 (R) 10 mg/m3 (T) 10 mg/m3 (T); 5 mg/m3 (R)
page 4 of 8
Limestone 15 mg/m3 (T); 5 mg/m3 (R) 10 mg/m3 10 mg/m3 (T); 5 mg/m3 (R)
Exposure Controls
Appropriate engineering controls : Use ventilation adequate to keep exposures (airborne levels of
dust, fume, vapor, etc.) below recommended exposure limits.
Hand protection : Wear suitable gloves.
Eye protection : Wear approved eye protection (properly fitted dust- or splash-
proof chemical safety goggles) and face protection (face shield).
Skin and body protection : Wear suitable protective clothing.
Respiratory protection : A NIOSH approved dust mask or filtering facepiece is
recommended in poorly ventilated areas or when permissible
exposure limits may be exceeded. Respirators should be selected
by and used under the direction of a trained health and safety
professional following requirements found in OSHA’s respirator
standard (29 CFR 1910.134) and ANSI’s standard for respiratory
protection (Z88.2).
Environmental exposure controls : Maintain levels below Community environmental protection
thresholds.
Other information : Handle according to established industrial hygiene and safety
practices.
page 5 of 8
Decomposition Hazards : Reacts with water to form calcium hydroxide which can
irritate/damage skin. Cement dissolves in hydrofluoric acid,
producing corrosive silicon tetrafluoride gas.
Components Toxicity
Cement, Portland No data
Gypsum (Calcium Sulfate) Oral LD50 Rat >2000 mg/kg
Limestone Oral LD50 Rat 6450 mg/kg
page 6 of 8
Mobility in Soil to Groundwater : Not reported/no data available.
Environmental Fate : Not reported/no data available.
Other Environmental Precautions
or Information : Avoid release to the environment. Prevent material from
entering sewers, drains, ditches or waterways.
The transport regulation are cited according to international regulations and in the form applicable in
Indonesia. Possible national deviation in other is not considered.
page 7 of 8
In case of contact with eyes, rinse immediately with plenty of
water and seek medical advice. Wear suitable protective
clothing,gloves and eye protection. In case of accident or if you
feel unwell, seek medical advice immediately (show the label
where possible).
Notice to reader :
The information provides here in is believed by PT. Semen Indonesia (Persero) Tbk. to be accurate.
Health and safety precaution in this data sheet may not be adequate for all individuals or situations.
User shave the responsibility to comply with all laws and procedures applicable to the safe handling
and use of the product, to determine the suitability of the product for its intended use, and to
understand possible hazard as sociated with mixing Portland Cement with other materials.
Since conditions of use are outside the company’s controls, the company makes no warranties,
expressed or implied and no liability in connection with any use of this information.
This MSDS characterizes the product with regard to the appropriate safety precautions, it does not
represent a guarantee of the properties of the product.
page 8 of 8