PHILIPP Product Range 2019 - Transport and Mounting Systems For Prefabricated Units
PHILIPP Product Range 2019 - Transport and Mounting Systems For Prefabricated Units
Product Range
Version: 2019
Our aims–
ambitious, customer-focused and feasible!
PHILIPPGROUP
PHILIPP – Strength and stability
It is an undisputed fact that building with precast con-
crete elements offers many planning and economic ad-
vantages in the construction of modern industrial and
office buildings as well as all kind of commercial con-
structions. Hereby, diverse structural precast concrete
elements take over multiple functions in the typical
skeleton construction. In this case the use of high-ca-
pacity and high-quality components is almost a matter
of course and an integral part of modern prefabricated
construction.
4 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 5
Transport and mounting – with safety
Transport anchors face daily "heavy" challenges during transport and mounting of precast concrete ele-
ments. Here, both the safety of people in the precast factory and on the construction site as well as the
safety in use are always in the centre of attention. Precisely and high-grade produced transport anchors
from PHILIPP prove the quality and thus create the required safety. Continuous quality assurance activities
additionally create confidence.
A suitable solution for almost every transport and mounting process of precast concrete elements of all kind
can be offered by PHILIPP. Although PHILIPP meets the constantly increasing requirements with product
optimizations of its standard portfolio or individually adapted solutions.
On the one hand, transport anchors are not subject to approval, on the other hand, both the so-called Ma-
chinery Directive and the VDI/BV-BS 6205 guideline series define in detail their manufacture, design and
application. The consistent CE-marking of the PHILIPP transport anchor systems is done on the basis of
these guidelines.
For each anchor system a detailed Installation and Application Instruction is available, providing important
information on prerequisites, reinforcement, load-bearing capacities (for steel and concrete) and much more.
Transport anchor systems
6 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 7
Threaded transport anchors
Transport anchor systems
Recommended use
Beam Stairs
8 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Anchor overview
Recommended use Transport anchor Types
Version: straight tail Version: offset Version: long wavy tail Compact anchor
Lifting insert with cross hole Lifting insert with crimped end Threaded anchor elongation
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 9
Threaded transport anchors for the lifting of e.g. wall-like elements
PHILIPPGROUP
PHILIPP Threaded transport anchor For further details of the application and design of the threaded transport anchor
straight tail please refer to our website www.philipp-group.de.
VB3-T-002-en - 02/18 - PDF
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
10 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Threaded transport anchor - with offset
Øds
PHILIPP Threaded transport anchor For further details of the application and design of the threaded transport anchor
with offset please refer to our website www.philipp-group.de.
T-054-en - 01/17
VB3-T-054-en
Version: offset
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 11
Threaded transport anchors for the lifting of e.g. wall-like elements
The Threaded anchor long wavy tail also offers a wide range of
applications. Its speciality lies primarily in walls as well as bar-
shaped elements (purlin, waler, beams etc.). With the waveform
and the ribbed reinforcing steel, modes of operation are combined
in the concrete and thus enable shorter embedment depths. All
load directions can be realised with the Threaded anchor long L
wavy tail easily. Øds
PHILIPPGROUP
PHILIPP Threaded transport anchor For further details of the application and design of the Threaded transport anchor
long wavy tail please refer to our website www.philipp-group.de.
VB3-T-003-en - 07/18 - PDF
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
12 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Compact anchor
PHILIPP Compact anchor For further details of the application and design of the Compact anchor please refer
to our website www.philipp-group.de.
VB3-T-005-en - 01/16
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 13
Threaded transport anchors for the lifting of e.g. wall-like elements
Lifting inserts with cross hole are simple but versatile transport
anchors within the PHILIPP Threaded anchor system. The applied
force into the precast concrete element - typically walls or bar-
shaped elements - is done via the reinforcement to be planned
separately and inserted through the cross hole. Axial-, diagonal L
and lateral tension are no problem for the Lifting insert with cross
hole.
PHILIPP Lifting insert with cross hole For further details of the application and design of the Lifting insert with cross hole
please refer to our website www.philipp-group.de.
VB3-T-011-en - 01/18
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
14 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Lifting insert with crimped end
PHILIPP Lifting insert with crimped end For further details of the application and design of the Lifting insert with crimped
end please refer to our website www.philipp-group.de.
VB3-T-012-en - 01/18
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 15
Threaded transport anchors for the lifting of e.g. wall-like elements
PHILIPP Threaded transport anchor elongation For further details of the application and design of the Threaded transport anchor
elongation please refer to our website www.philipp-group.de.
VB3-T-055-en - 08/18
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
16 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 17
Threaded transport anchors
Transport anchor systems
Recommended use
18 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Anchor overview
Recommended use Transport anchor Types
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 19
Threaded transport anchors for the lifting of e.g. slab-like elements
The Threaded anchor short wavy tail is intended for use exclu-
sively in slab-like elements. With the waveform and the ribbed re-
inforcing steel, modes of operation are combined in the concrete
and thus enable shorter embedment depths. The load directions
axial and diagonal tension are available without restrictions for
this anchor type. L
Øds
PHILIPP Threaded transport anchor For further details of the application and design of the Threaded transport anchor
short wavy tail please refer to our website www.philipp-group.de.
VB3-T-004-en - 01/16
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
20 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Screw anchor
Due to their low embedment depth, screw anchors are the ideal
solution for light, thin slab-like precast concrete elements. In ad-
dition, under certain conditions the additional reinforcement for
diagonal tension can be omitted, so that the installation of the
screw anchor is quite simple. The load directions axial and diago- L
nal tension are available without restrictions for this anchor type.
Screw anchor
Ref.-No. Type Steel Dimension
galvanised bearing capacity Axial tension (βmax 12.5°)
L Diagonal tension (βmax 45°)
[kN] [mm]
67SA12 RD 12 5.0 60
67SA14 RD 14 8.0 70
67SA16 RD 16 12.0 80
67SA18 RD 18 16.0 90
67SA20 RD 20 20.0 100
67SA24 RD 24 25.0 115
67SA30 RD 30 40.0 150
Also available in version stainless steel (ref.-no. 75SA__VA).
PHILIPP Screw anchor For further details of the application and design of the Screw anchor please refer to
our website www.philipp-group.de.
VB3-T-007-en - 01/16
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 21
Threaded transport anchors for the lifting of e.g. slab-like elements
71FL16 35
RD 16 12.0 35 50
71FL16L 70
71FL20 47
RD 20 20.0 60 60
71FL20L 80
71FL24 54
RD 24 25.0 60 80 Axial tension (βmax 12.5°)
71FL24L 100
Diagonal tension (βmax 45°)
71FL30 72
RD 30 40.0 80 100
71FL30L 120
71FL36 84
RD 36 63.0 100 130
71FL36L 140
71FL42 98
RD 42 80.0 130 130
71FL42L 160
71FL52 119
RD 52 125.0 130 150
71FL52L 200
Also available in version stainless steel (ref.-no. 77FL__VA).
PHILIPP Capped end anchor For further details of the application and design of the Capped end anchor please
refer to our website www.philipp-group.de.
VB3-T-009-en - 07/19 - PDF
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
22 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 23
Lifting devices / accessories
Transport anchor systems
Lifting devices
Wide range of lifting devices for every requirement on the lifting and transport of precast concrete elements
ll lifting devices applicable for axial, diagonal and lateral lifting situations
A
Optimal technical coordination between lifting device and Threaded transport anchor
All lifting devices available with metric thread or special round thread (RD) with a metric pitch
High-quality and tested lifting devices
Clear colour code for identification in the entire system
Accessories
Marking rings (plastic) for a safe assignment of transport anchors and lifting devices
ide range of retaining caps and recess formers coordinated with the lifting devices
W
Sealing caps in different materials, dimensions exactly matched to retaining caps and recess formers
24 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
sion
sion
sion
sion
Axial ten
D
Axial ten
Axial ten
Axial ten
Axial ten
ia D D D D
ia ia ia ia
go go go go go
on
n
io
io
io
io
na na na na na
si
s
en
en
en
en
en
lt lt lt lt lt
en en en en en
lt
lt
lt
lt
lt
no
na
na
na
na
ta si si si si si na
on wed on on on on
go
llo
go
go
go
go
we allo
ia
ia
ia
ia
ia
d not
D
Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 25
Lifting devices / Accessories
ion
ion
ion
ion
ion
ion
Axial tens
Axial tens
Axial tens
Axial tens
Axial tens
Axial tens
D D D D D D
ia ia ia ia ia ia
go go go go go
n
go
io
io
io
io
io
na na na na na
io
na
ns
ns
ns
ns
ns
ns
l te l te l te l te l te
l te
l te
l te
l te
l te
l te
l te
ns ns ns ns ns
na
na
na
na
na
no ns
na
t al io io io io io io
wed
go
go
go
go
go
n n n n n
go
low n allo
ia
ia
ia
ia
ia
ed ia
not
D
D
Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension Lateral tension
Plane to surface
- - -
Sizes: Type 12 to 52 - -
Ref.-no.: 72KHN__STK
Sizes: Type 12 to 52 - - -
Ref.-no.: 72KHN__SZ15
Ref.-no.: 72KH__
Sizes 56 and 60 only with RD-thread, diagonal tension ≤ 30° possible, diagonal tension > 30° and lateral tension not possible.
Special solutions of fixations, nailing plates and sealing caps on request!
This is just a summary of our product range, which is only valid with appropriate Installation and Application Instructions, and datasheets of accessories.
26 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Sealing caps
Wirbelstar KH Plastic Stainless steel Plastic Stainless steel Plastic Plastic Stainless steel Stainless steel
with KH ring (concrete grey) with slot (concrete grey) with slot (concrete grey) (concrete grey) with slot
rotatable or or or
under load internal hexagon internal hexagon internal hexagon
...-S
...-S
...-S
...-ISK
ion
...-ISK
Axial tens
...-ISK
D
ia
go
n
io
na
ns
l te
l te
ns
na
io
go
n
ia
D
- - - - - - -
- - - - - -
PHILIPP Ø40
- - - - - -
PHILIPP Ø40
- - - - - -
PHILIPP Ø40
- - - - - - - -
- - - - - -
- - - - - -
- - - - - -
- - - - -
- - - - -
- - - - -
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 27
Transport loop system (TPS system)
Transport anchor systems
Recommended use
28 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Transport loop Transport anchor TPS 16 + 24 Transport anchor TPS 30 Transport anchor TPS 36
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 29
Transport loop system (TPS-system)
Transport loop
The Transport loop system (TPS) has been specially developed for
the transport of (thin-walled) pipe and manhole elements as well
as light, retaining walls or similar. In particular, the combination
of a simple, short anchor and a screw-on and therefore reusable
lifting loop makes this system so attractive.
Transport loop
Ref.-No. Type Bearing Dimension
capacity L
[kN] [mm]
67TPS122000 TPS 16 20.0 280
67TPS154000 TPS 24 40.0 310
67TPS185200 TPS 30 52.0 390
67TPS206300 TPS 36 63.0 525 not
permissible
PHILIPP Transport loop system For further details of the application and design of the Transport loop system please
refer to our website www.philipp-group.de.
VB3-T-046-en - 03/17
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors www.philipp-group.de
30 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Transport loop anchor
130
100
L
L
L
100
Type 16 and 24
Type 36
Type 30
PHILIPP Transport loop system For further details of the application and design of the Transport loop system please
refer to our website www.philipp-group.de.
VB3-T-046-en - 03/17
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 31
Power System SL
Transport anchor systems
Recommended use
32 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
SL 16 SL 24 SL 30 SL 42 SL52
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 33
Power System SL
PHILIPP Power System SL For further details of the application and design of the Threaded transport anchor SL
please refer to our website www.philipp-group.de.
VB3-T-028-en - 01/16
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors www.philipp-group.de
34 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Lifty SL
M-LH
Lifty SL
Ref.-No. Type Thread Bearing capacity Dimensions
b l
[M-LH] [kN] [mm] [mm]
62LISL16M SL 16 16 20.0 50 150
62LISL24M SL 24 24 50.0 50 162
62LISL30M SL 30 30 80.0 50 177
62LISL42M SL 42 42 145.0 65 220
62LISL52M SL 52 52 200.0 65 220
PHILIPP Power System SL For further details of the application and design of the Lifty SL please refer to our
website www.philipp-group.de.
VB3-T-028-en - 01/16
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 35
Power System SL
With the Marking ring SL with clip on the one hand a clear identi-
fication of the anchor when installed is possible and on the other
hand to secure the position of the optional additional reinforce- ØD
ment (for diagonal or lateral tension). Ød
Due to the explicit colour coding a quick and correct assignment
to the corresponding lifting device is ensured.
B h
PHILIPP Power System SL For further details of the application and design of the Marking ring SL with clip
please refer to our website www.philipp-group.de.
VB3-T-028-en - 01/16
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors www.philipp-group.de
36 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Nailing plate SL, plastic
hT
H
Ød
PHILIPP Power System SL For further details of the application and design of the Nailing plate SL please refer
to our website www.philipp-group.de.
VB3-T-028-en - 01/16
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Threaded anchors www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 37
Spherical head transport anchor
Transport anchor systems
Recommended use
38 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Anchor Overview
Recommended use Transport anchor Types
Spherical head transport anchor Version: with offset Spherical head rod anchor Version: double-head
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 39
Spherical head anchors for lifting of e.g. wall-like elements
2.5PH
-
KK170
PHILIPP Spherical head anchor For further details of the application and design of the Spherical head anchor please
refer to our website www.philipp-group.de.
VB3-T-032-en - 01/16
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system
40 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Spherical head anchor - with offset
2.5PH
-2
KK 80
PHILIPP Spherical head anchor For further details of the application and design of the Spherical head anchor with
offset please refer to our website www.philipp-group.de.
VB3-T-034-en - 01/17
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 41
Spherical head anchors for lifting of e.g. wall-like elements
2.5PH
-4
KK 00
PHILIPP Spherical head rod anchor For further details of the application and design of the Spherical head rod anchor
please refer to our website www.philipp-group.de.
VB3-T-035-en - 01/16
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system
42 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Spherical head transport anchor - double-head
32PH
-7
KK00
PHILIPP Spherical head double-head anchor For further details of the application and design of the Spherical head double head
anchor please refer to our website www.philipp-group.de.
VB3-T-065-en - 01/18
www.philipp-group.de
Installation and Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 43
Spherical head anchors for lifting of e.g. wall-like elements
Exclusively for the Spherical head anchor system the Spherical daily use. In order to increase the safety of the clutch a check
head lifting clutch is designed and enables with its simple mecha- gauge for a fast and easy test of important wear measurements
nism an easy, safe and very fast (un)coupling of a precast element. is available.
Due to its robust design it is very durable and therefore ideal for
Suitable rubber recess formers in various sizes fix the Spherical for a simple and safe coupling of the lifting clutch.
head anchor securely in position and create the recess required
Recess formers for the Spherical head anchor system are also available in steel and steel with magnets.
PHILIPP Spherical head lifting clutch For further details of the application and design of the Spherical head lifting clutch
please refer to our website www.philipp-group.de.
VB3-T-037-en - 08/18
www.philipp-group.de
Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system
44 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Accessories
In order to fix a rubber recess former for the Spherical head an- for individually screwing in a fixing element. An easy release and
chor system to the formwork, we offer either an accessory with reuse of the recess former is thus guaranteed.
ready-made threaded rod and wing nut or with an internal thread
L
83-SGS-200 KK 15.0 / 20.0 12 100
S
83-SIG-075 KK 7.5 / 10.0 12 15.0
83-SIG-200 KK 15.0 / 20.0 12 15.0
PHILIPP Accessories For further details of the application and design of the Accessories for the Spherical
head transport anchor system please refer to our website www.philipp-group.de.
VB3-T-038-en - 01/16
www.philipp-group.de
Data sheet
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 45
Spherical head transport anchor
Transport anchor systems
Recommended use
46 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Anchor Overview
Recommended use Transport anchor Types
Spherical head transport anchor KK 5.0 - KK 20.0
Tubes / shafts / tanks
Spherical head transport anchor - double headed KK 1.3 - KK 2.5
Floor and roofing slabs Spherical head flat steel anchor KK 2.5 - KK 10.0
Spherical head transport anchor Spherical head flat steel anchor Version: double headed Spherical head lifting clutch
Accessories
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 47
Spherical head anchors in tubes, manholes, shafts and slab-like elements
These Spherical head anchors with their short lengths are spe-
cially optimised for the lifting of tubes and shafts. They convince
with their simplicity and robust components as well as an easy
installation with the appropriate accessories. All load directions
can be realised with the ‘short’ Spherical head anchors without L
any problems.
5.0PH
Spherical head transport anchors for tubes, shafts and manholes -
KK120
Ref.-No. Type Steel Dimension
bright bearing capacity
L
[kN] [mm]
81-050-075 50.0 75 Axial tension (γmax 15°)
81-050-085 50.0 85 Lateral tension (γmax 90°)
81-050-095 KK 5.0 50.0 95
81-050-110 50.0 110 Axial tension (βmax 12.5°)
81-050-120 50.0 120 Diagonal tension (βmax 45°)
81-075-085 75.0 85 Lateral tension (βmax 90°)
81-075-095 75.0 95
81-075-100 75.0 100
KK 7.5
81-075-120 75.0 120
81-075-140 75.0 140
81-075-165 75.0 165
81-100-115 100.0 115
81-100-120 100.0 120
81-100-135 100.0 135
81-100-150 KK 10.0 100.0 150
81-100-170 100.0 170
81-100-200 100.0 200
81-100-250 100.0 250
81-150-140 150.0 140
81-150-165 150.0 165
KK 15.0
81-150-200 150.0 200
81-150-300 150.0 300
81-200-165 200.0 165
81-200-200 200.0 200
KK 20.0
81-200-250 200.0 250
81-200-340 200.0 340
- also available in electro-galvanised b.z.p. (e.g. 81-100-150VC)
or hot-dip galvanised h.d.g. (e.g. 81-100-150FV) version.
- stainless steel on request.
PHILIPP Spherical head anchor For further details of the application and design of the Spherical head anchor please
refer to our website www.philipp-group.de.
VB3-T-033-en - 01/16
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system www.philipp-group.de
48 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Spherical head flat steel anchor
a
2.5PH
-
KK85
PHILIPP Spherical head flat steel anchor For further details of the application and design of the Spherical head flat steel
anchor please refer to our website www.philipp-group.de.
VB3-T-047-en - 08/18 - PDF
Data sheet
www.philipp-group.de
/ Download-Center / Transport and Mounting Systems / Technical documents
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 49
Spherical head anchors in tubes, manholes, shafts and slab-like elements
Further information about the corresponding lifting device and fixing accessories can be found on pages 44 and 45.
PHILIPP Spherical head double-headed anchor For further details of the application and design of the Spherical head double head-
ed anchor please refer to our website www.philipp-group.de.
VB3-T-036-en - 01/16
Data sheet
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system www.philipp-group.de
50 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Spherical head system
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 51
Hole anchor system
Transport anchor systems
Recommended use
52 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Anchor Overview
Recommended use Transport anchor Types
one-sided
double-sided
Flat feed anchor Sandwich panel anchor Ring clutch Recess former
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 53
Hole anchor system
Spread anchor
With its special spreading at the anchor foot, this transport anchor
is very multifunctional. It offers an optimum anchoring for thin-
walled elements as well as large-format concrete elements. Beams,
columns, walls and π-slabs are typical applications for that anchor
type. For special requirements, the Spread anchor can be used also
as a Two-hole anchor. For this purpose, the anchor has an addi-
tional slotted hole.
PH
2.5 L
15
Spread anchor SA
PHILIPP Hole anchor system For further details of the application and design of the Spread anchor please refer to
our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
54 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Two-hole anchor
For more light elements such as (small) walls and bar-shaped ele-
ments, the Two-hole anchor is a simple and often used transport
anchor system. The applied force into the precast concrete ele-
ment is done via the reinforcement to be planned separately and
inserted through the slotted hole. On request, Two-hole anchors
with additional holes resp. in longer dimensions can be supplied.
PH
2.5
9
ZA
L
2.5 PH
SA 15
48ZA020090 LA 2.0 20.0 90 Diagonal tension (βmax 60°)
48ZA025090 LA 2.5 25.0 90
48ZA030120 LA 3.0 30.0 120
48ZA040120 LA 4.0 40.0 120
2.5 PH
PHILIPP Hole anchor system For further details of the application and design of the Two-hole anchor please refer
to our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 55
Hole anchor system
2.5 PH
SA 15
48AB014200 LA 1.4 14.0 200
48AB025230 LA 2.5 25.0 230
48AB040270 LA 4.0 40.0 270
48AB050290 LA 5.0 50.0 290
2.5 PH
SA 15
PHILIPP Hole anchor system For further details of the application and design of the Erection anchor double-sided
please refer to our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
56 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Erection anchor - one-sided
SA 15
PHILIPP Hole anchor system For further details of the application and design of the Erection anchor one-sided
please refer to our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 57
Hole anchor system
Plate anchor
PA 8
crosswise with additional rebars as standard.
2.5 PH
L
e
e
Plate anchor
Ref.-No. Type Steel Dimensions
Axial tension
black steel bearing capacity (βmax 30°)
L e Diagonal tension
[kN] [mm] [mm] (βmax 60°)
48PA0140055 LA 1.4 14.0 55 80
48PA0250080 LA 2.5 25.0 80 80
48PA0500120 LA 5.0 50.0 120 100
48PA1000160 LA 10.0 100.0 160 140
- also available in electro-galvanised b.z.p. (e.g. 48PA0250080VC)
or hot-dip galvanised h.d.g. (e.g. 48PA0250080GV) version.
PHILIPP Hole anchor system For further details of the application and design of the Plate anchor please refer to
our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
58 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Flat foot anchor
Also for the transport of thin, slab-like elements, the Flat foot an-
chor can be used as an alternative to the Plate anchor. Especially
with higher concrete strengths, the maximum load-bearing capac-
ity of this anchor type is achieved at the time of lifting. The anchor
FF 7
2.5 PH
foot shall be reinforced crosswise with additional rebars.
PHILIPP Hole anchor system For further details of the application and design of the Flat foot anchor please refer
to our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 59
Hole anchor system
L
PH
2.5
25
SW
PHILIPP Hole anchor system For further details of the application and design of the Sandwich panel anchor
please refer to our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
60 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Ring clutch / recess former
The corresponding lifting device for the Hole anchor system is the load classes. There is no danger of mix-up, because only the cor-
Ring clutch. It consists of a hinged handle and a coupling head, rect Ring clutch fits to the corresponding transport anchor sizes.
which fits only in the boring of the Hole transport anchors. The
Ring clutch is available in four sizes, each suitable for 3 - 4 anchor
Ring clutch
b
Ref.-No. Type Bearing Dimensions
capacity
L a b
[kN] [mm] [mm] [mm] a
48RK025265 LA 2.5 25.0 265 70 58
48RK050330 LA 5.0 50.0 330 86 65 L
48RK100425 LA 10.0 100.0 425 112 90
48RK260605 LA 26.0 260.0 605 160 120
Matching recess formers (rubber, steel or magnetic versions) in the required recess for a simple and safe coupling of the clutch.
various sizes fix the Hole anchors securely in position and create
PHILIPP Hole anchor system For further details of the application and design of the Ring clutch please refer to
our website www.philipp-group.de.
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Hole anchor systems www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 61
Cast-in lifting hoops
Transport anchor systems
Recommended use
Bar-shaped elements
62 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Anchor Overview
Recommended use Lifting hoops Types
Cast-in lifting hoop Wire protection pulley Angled loop Polypropylene lifting loop
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 63
Cast-in lifting hoops
2016
shaped elements, beams and girders. Used wire-rope is bonded
2500kg
and forms a loop which encloses a concrete core – thus it enables
high load-bearing capacities for this transport anchor type. A spe-
cial lifting device is not required for transport and mounting of the
elements. Moreover, Cast-in lifting hoops also offer high perfor-
mance at a low price and thus combine many advantages. H
PHILIPP Cast-in lifting hoop For further details of the application and design of the Cast-in lifting hoop please
refer to our website www.philipp-group.de.
VB3-T-040-en - 05/18
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Lifting hoops www.philipp-group.de
64 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Cast-in lifting hoop type AS 28.0 - AS 95.0
2016
ed and mounted, the use of Cast-in lifting hoops for the heavy load
2500kg
range up to 95 t capacity is obvious. Used wire-rope is bonded
and forms a loop which encloses a concrete core – thus it enables
very high load-bearing capacities for this transport anchor type.
Although this heavy-duty anchor is always combined with an indi-
vidual design service from PHILIPP, the Cast-in lifting hoop in this H
application area is nevertheless convincing with an unbeatable
B
price / performance ratio.
PHILIPP Drahtseilabhebeschlaufe For further details of the application and design of the Cast-in lifting hoop please
refer to our website www.philipp-group.de.
VB3-T-041-de - 04/19 - PDF
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Lifting hoops www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 65
Cast-in lifting hoops
ØD
Wire protection pulley (steel version)
Ref.-No. Type Dimensions for
Cast-in lifting hoop
ØD b
[mm] [mm] Type
44SR008020 2.0 43 18 AS 0.8 - AS 2.0
44SR025063 6.3 75 32 AS 2.5 - AS 6.3
44SR080160 16.0 112 56 AS 8.0 - AS 16.0
44SR200250 25.0 148 68 AS 20.0 - AS 25.0
44SR280520 52.0 202 95 AS 28.0 - AS 52.0
44SR570990 99.0 256 140 AS 57.0 - AS 95.0
Also available in POM material and as a set (picture) Set (Wire protection pulley, shackle, master link)
Picture 1
Table 1: Dimensions
Ref.-No. Type ØD ØDR ØdS.max ØdN b Weight for
(ØDR ≥ 3,5 × ØdS) Cast-in lifting hoop
[mm] [mm] [mm] [mm] [mm] [kg/pc.] [Type]
For further details of the application and design of the Wire protection pulley please
Version: steel
44SR008020 2.0 43 31.5 9.0 17.0 18.0 0.12 AS 0.8 - AS 2.0
44SR025063 6.3 75 56.0 16.0 28.0 32.0 0.75 AS 2.5 - AS 6.3
44SR080160 16.0 112 84.0 24.0 44.0 56.0 2.90 AS 8.0 - AS 16.0
PHILIPP Wire protection pulley 44SR200250 25.0 148 112.0 32.0 53.0 68.0 6.25 AS 20.0 - AS 25.0
44SR280520 52.0 202 154.0 44.0 73.0 95.0 16.40 AS 28.0 - AS 52.0
44SR570990 99.0 256 196.0 56.0 98.0 140.0 29.00 AS 57.0 - AS 95.0
www.philipp-group.de
Application Instruction
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Lifting hoops
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • July 2019 2
66 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Polypropylene lifting loop
H
B
PHILIPP Polypropylene lifting loop For further details of the application and design of the Polypropylene loop please
refer to our website www.philipp-group.de.
VB3-T-042-en - 08/18
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Lifting hoops www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 67
Cast-in lifting hoops
Angled loop
h
L
Angled loop
Ref.-No. Type Steel Dimensions
bearing capacity Axial tension (βmax 12.5°)
h L
Diagonal tension (βmax 30°)
[kN] [mm] [mm]
44W10180350 AS 2.5 25.0 180 350
44W12230380 AS 4.0 40.0 230 380
44W14230380 AS 5.2 52.0 230 380
PHILIPP Angled loop For further details of the application and design of the Angled loop please refer to
our website www.philipp-group.de.
VB3-T-043-en - 01/16
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Lifting hoops www.philipp-group.de
68 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Lifting hoops
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 69
Further systems
Transport anchor systems
Recommended use
70 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 71
Further systems
Masonry anchor
Masonry anchors are designed for the transport of prefabricated masonry panels. They
are inserted through the corings of the bricks and finally grouted with mortar. Due to the Type 1
long anchor with a waved end the safe load transfer into the unit is guaranteed. With three
different anchor head versions nearly every lifting device can be used for transport and
mounting of masonry walls.
1200
69/2 kg
01
RD16 2
L
Øds
C K
P 100
- K
H 0
73HM14___ 8.0 10 as required 14
73HM16___ 12.0 12 as required 16
L
Øds
73HM18___ 16.0 14 as required 18
73HM20___ 20.0 16 as required 20
73HM24___ 25.0 16 as required 24
73HM30___ 40.0 20 as required 30
PHILIPP Masonry anchor For further details of the application and design of the Masonry anchors please refer
to our website www.philipp-group.de.
VB3-T-044-en - 01/16
Data sheet
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Further systems www.philipp-group.de
72 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Lightweight concrete anchor
Anchors for lightweight concrete are designed for wall-like elements made of concrete
with open structure resp. lightweight concrete with low concrete strengths. A U-profile Type 1
welded to the anchor foot guarantees the safe transfer of force into the lightweight con-
crete. With three different designs of the anchor head, the requirements for a specific
lifting device for the transport and mounting process can be met.
1200
69/2 kg
01
RD16 2
L
Ref.-No. Steel Dimensions Thread
Type 3
bearing capacity Øds L a b RD
[kN] [mm] [mm] [mm] [mm] ØD
73HM16____LB 12.0 10 as required 115 60 16
C K
P 100
- K
H 0
73HM20____LB 20.0 12 as required 115 60 20
73HM24____LB 25.0 14 as required 175 60 24
73HM30____LB 40.0 16 as required 230 60 30 Øds
L
Lightweight concrete anchor with spherical head (type 3) b
Ref.-No. Steel Dimensions
bearing capacity Øds L a b ØD
a
[kN] [mm] [mm] [mm] [mm] [mm]
73KK10____LB 13.0 10 as required 115 60 18
73KK12____LB 25.0 12 as required 115 60 25
73KK14____LB 32.0 14 as required 175 60 25
L
b
73KK16____LB 40.0 16 as required 230 60 36
PHILIPP Lightweight concrete anchor For further details of the application and design of the Lightweight concrete anchor
please refer to our website www.philipp-group.de.
VB3-T-045-en - 01/16
Data sheet
/ Products / Transport and Mounting Systems / Transport Anchor Systems / Further systems www.philipp-group.de
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 73
Creating connections - safely
In modern skeleton construction, a wide variety of connection solutions are required and applied. Solutions
listed here are focused on vertical connections for walls to each other and walls to columns.
Most of these connections can be realised with mounting parts such as boxes or rails, which generate a form
and force fit connection in the joints. Wire rope loops with a high flexibility are used as reinforcement, which
allow connections that are hardly possible with other connecting elements. Finally, the joints are filled with a
high-strength mortar.
A differentiation is made here between systems via which static loads are to be transferred or simple, con-
structive connections are sufficient. If civil engineers require specific designed connections, connecting sys-
tems with German approvals from DIBt and systems with calculation basis Eurocode 2 are available. Everything
else can be easily and quickly connected by constructive loops or rails.
All told, wire rope loops simplify the installation of precast concrete elements by their flexibility significantly.
Connection technology
74 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Connection technology
German approved systems for high forces Page 76
Constructive rails and loops Page 82
Restraint dowel plate / dowelling system Page 86
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 75
German approved systems for high forces
German approved systems for high loads are required if
there are high (shear)-forces to be transferred into the
Connection technology
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Possible applications
Design tool
For the design of the German approved
systems for high forces an easy-to-use
and user-friendly software is available
on our website to provide individual de-
signs on the basis of simple geometric
data.
www.philipp-group.de
76 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 77
German approved systems
The Power One system is a connecting device for the force- and
form-fit connection of primarily thin precast concrete elements
starting with 10 cm thickness. It is able to safely transfer forces in
all three directions, parallel and right-angled to the joint as well
as tensile forces in rope direction. High design values as also the
consideration of fire exposure characterise this connection solu-
tion.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2093 B1
Institut für
Werkstoffe im Bauwesen
Technische Universität
B2
Darmstadt
SL
L1
PHILIPP Power One System For further details of the application and design of the Power One system please
refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2093
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-V-016-en - 09/19 - PDF
Installation Instruction
78 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Power Duo System
Z – 21.8-2028 Z – 21.8-2066
SL
H SL
H
L
B1 B1
L
L1 L1
PHILIPP Power Duo System For further details of the application and design of the Power Duo system please
refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2028
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2066
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-V-001-en - 02/19 - PDF
Installation Instruction
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 79
German approved systems
Power OS
Power OS rail
Ref.-no. Dimensions
B1 B2 H L L1 SL
[mm] [mm] [mm] [mm] [mm] [mm]
84POS201555 80 70 20 1250 250 155
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2093
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
SL
B1
B2
L L1
PHILIPP Power OS rail For further details of the application and design of the Power OS please refer to our
website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2098
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-V-017-en - 09/19 - PDF
Installation Instruction
80 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Power Box System
Small but not a less powerful solution for a force- and form-fit con-
nection of precast concrete elements – the Power Box. With this,
shear forces parallel and right-angled to the joint are transferred
safely. High design values as also the consideration of fire expo-
sure characterise this connection solution.
Power Box
Ref.-No. Dimensions
SL B H L L1
[mm] [mm] [mm] [mm] [mm]
54PB120 120 80 25 220 190
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
B
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1840
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
SL
L1
L
PHILIPP Power Box System For further details of the application and design of the Power Box system please
refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1840
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-V-002-en - 08/18 - PDF
Installation Instruction
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 81
Constructive rails and single loops
Connecting rails and loops are always used for construc-
tive connections when no forces have to be transferred
Connection technology
82 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 83
Constructive rails and single loops
Connecting rail
Connecting rail B3
Ref.-no. Number Dimensions B1
SL H L B1 B2 B3 L1
[pcs.] [mm] [mm] [mm] [mm] [mm] [mm] [mm] SL
PHILIPP Connecting rails and loops For further details of the application and design of the Connecting rails please refer
to our website www.philipp-group.de.
VB3-V-004-en - 07/18 - PDF
Installation Instruction
84 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Connecting loop
Connecting loop
Ref.-no. Dimensions
L L1 B H SL
[mm] [mm] [mm] [mm] [mm]
Metal box
54VSM080 160 190 50 20 80
54VSM100 160 190 50 20 100
54VSM120 160 190 50 20 120
54VSM140 190 190 50 20 140
Plastic box
54VS080 160 210 78 42 80
54VS100 160 210 78 42 100
54VS120 160 210 78 42 120
This version is a combination of a single steel wire rope and a This version is a combination of a single steel wire rope and a
metal recess former (box) in which the ready-for-use wire rope is plastic recess former (box) in which the ready-for-use wire rope
inserted. is inserted.
B B H
H
L1 L1
L L
SL SL
PHILIPP Connecting rails and loops For further details of the application and design of the Connecting loop please refer
to our website www.philipp-group.de.
VB3-V-004-en - 07/18 - PDF
Installation Instruction
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 85
Restraint dowel / dowelling system
Pocket-pin-connections are very typical for prefabricat-
ed constructions and often used as force-transferring
Connection technology
Recommended use
Walls
Dowelling system
C onstructive connection between stacked precast concrete elements
System of Rebar pocket and Concrete pocket
hree pocket sizes for different rebar diameters
T
Flexibility in the alignment of the connection by shape and size of the Concrete pocket
86 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Connection: Rebar pocket / Restrain dowel plate Connection: Rebar pocket / Concrete pocket
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 87
Restraint dowel / dowelling system
LDo
L
M
LDü
PHILIPP Restraint dowel plate For further details of the application and design of the Restraint dowel plate please
refer to our website www.philipp-group.de.
VB3-V-013-en - 03/16
Data sheet
88 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Dowelling system
For a simple fixation of two stacked concrete units the dowelling Both, the Rebar pocket and Concrete pocket are simply fixed to the
system is used. It consists of a Rebar pocket - available in three formwork by means of pocket holders during the production of the
sizes - for the upper precast concrete element, a Concrete pocket precast elements.
for the lower element and a suitable rebar to be provided on site.
72DT
72DH__
A
ØD
B
H a
Ød H1
b
h
72HH__ 72TH h1
PHILIPP Dowelling system For further details of the application and design of the Dowelling system please refer
to our website www.philipp-group.de.
VB3-V-006-en - 04/18 - PDF
Data sheet
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 89
Impressive facades need load-bearing connection devices
The appearance of many prefabricated buildings is essentially determined by the design of their facades.
Very often, these precast concrete elements are produced in the economical sandwich technology, which
includes a load-bearing layer, an inner insulation (layer) and a visible facing layer.
A common way to connect the facing layer to the load-bearing layer is to use anchors made of stainless
steel. These form a system of load-bearing anchors and pins, which transfers horizontal and vertical forces
into the load-bearing layer.
Both, the SPA and SA/FA system are two well established, long-time tested and state of the art solutions for
sandwich elements. For all these anchor types German approvals are available including generally accepted
calculation methods. For the design a user-friendly software is available as freeware on our website.
Facade technology
90 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Facade technology
Sandwich panel anchor system SA / FA Page 92
Sandwich panel anchor system SPA Page 98
Sandwich FT Anchor Page 102
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 91
System SA / FA
With the load-bearing anchors SA (Sleeve anchors) and/
or FA (Flat anchors) one is prepared for almost all chal-
lenges concerning the connection of the facing layer
with the load-bearing layer. Various systems from both
types of load-bearing anchors offer a wide range of solu-
Facade technology
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Design software
PHILIPP provides a free software for the de-
sign of the sandwich panel anchor systems.
Here are some advantages of the software
available on the PHILIPP website: www.philipp-group.de
92 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 93
Sandwich panel anchor SA / FA
Ød Z – 21.8-2013
drical design, a load transfer in all directions is ensured and thus Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Load-bearing anchor SA
Ref.-no. Dimensions
Ød t H
[mm] [mm] [mm]
77MA15___051 51 1.5 150 175 200 225 260 300
77MA15___076 76 1.5 150 175 200 225 260 300
77MA15___102 102 1.5 150 175 200 225 260 300
77MA15___127 127 1.5 150 175 200 225 260 300
77MA15___153 153 1.5 150 175 200 225 260 300
77MA15___178 178 1.5 150 175 200 225 260 300
77MA15___204 204 1.5 150 175 200 225 260 300
77MA15___229 229 1.5 150 175 200 225 260 300
77MA15___255 255 1.5 150 175 200 225 260 300
77MA15___280 280 1.5 150 175 200 225 260 300
The reference number has to be added by the required height H of the anchor.
E.g. load-bearing anchor SA, anchor thickness t = 1.5 mm, height H =225 mm, Ød = 204 mm ref.-no.: 77MA15225204
PHILIPP Sandwich panel anchor system SA / FA For further details of the application and design of the Sandwich panel anchor SA/
FA please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2013
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1986
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Installation Instruction
94 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Load-bearing anchor FA (Flat anchor)
Flat anchors are characterised by their flat design and the re- PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
t Z – 21.8-2013
80
77FA15______ 1.5 150 175 200 225 260 - - - -
120
160
200
77FA20______ 240 2.0 150 175 200 225 260 280 300 320 360
280
320
360
77FA30______ 3.0 - - - - 260 280 300 320 360
400
The reference number has to be added by the required height H and length L of the anchor.
E.g. load-bearing anchor FA, anchor thickness t = 3.0 mm, height H =280 mm, L = 320 mm ref.-no.: 77FA30280320
PHILIPP Sandwich panel anchor system SA / FA For further details of the application and design of the Sandwich panel anchor SA /
FA please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2013
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1986
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Installation Instruction
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 95
Sandwich panel anchor SA / FA
The Connector pin cross is a very simple load-bearing system con- Required Connector pin length of the load-bearing anchor CPC
sisting of two Connector pins positioned at a 90° angle to each
Insulation Required Connector pin lengths
other. For small to medium element sizes this low-priced system is thickness L
applicable and achieves very good design resistances without any hD CPC-04 CPC-05 CPC-06
additional reinforcement. Basically, the length L of the Connector [mm] [mm] [mm] [mm]
pins depends on the insulation thickness hD. 30 220 220 (220)
40 240 240 (240)
50
260 260 260
60
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Institut für
Werkstoffe im Bauwesen
Technische Universität
80
Darmstadt
PHILIPP Sandwich panel anchor system SA / FA For further details of the application and design of the Sandwich panel anchor SA /
FA please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2013
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1986
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Installation Instruction
96 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Connector pins VN / VB / AN
Z – 21.8-1986
Ød
grid. These pins are available in three types, Connector pins (VN), Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Connector stirrups (VB) and Clip-on pins (AN), and are always com- Ød
bined with a load-bearing anchor system. The stainless steel pins
available for each insulation layer thickness are provided in three H
H
diameters (Ø4, 5 and 6 mm) and are very easy to handle during
installation. H
Ød VB AN
Connector pin
Ref.-no. H Connector pin (type VN) Connector stirrup (type VB) Clip-on pin (type AN)
[mm] Ød = 4.0 Ød = 5.0 Ød = 6.0 Ød = 4.0 Ød = 5.0 Ød = 4.0 Ød = 5.0
77____160 160 VN40 - - VB40 - AN40 AN50
77____180 180 VN40 - - VB40 - AN40 AN50
77____200 200 VN40 VN50 - VB40 - AN40 AN50
77____220 220 VN40 VN50 - VB40 - AN40 AN50
77____240 240 VN40 VN50 - VB40 VB50 AN40 AN50
77____250 250 - - - VB40 VB50 AN40 AN50
77____260 260 VN40 VN50 - - - - -
77____280 280 VN40 VN50 - - VB50 AN40 AN50
77____300 300 VN40 VN50 - - VB50 AN40 AN50
77____320 320 - VN50 VN60 - VB50 - AN50
77____340 340 - VN50 VN60 - - - AN50
77____360 360 - - VN60 - - - AN50
77____380 380 - - VN60 - - - AN50
77____400 400 - - VN60 - - - -
77____420 420 - - VN60 - - - -
77____440 440 - - VN60 - - - -
77____460 460 - - VN60 - - - -
77____480 480 - - VN60 - - - -
77____500 500 - - VN60 - - - -
77____520 520 - - VN60 - - - -
The reference number has to be added by the required pin type and diameter.
E.g. Connector pin type VN; pin diameter Ød = 5.0 mm 50; height H = 280 mm ref.-no.: 77VN50280
PHILIPP Sandwich panel anchor system SA / FA For further details of the application and design of the Sandwich panel anchor SA/
FA please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-2013
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1986
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Installation Instruction
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 97
System SPA
Sandwich panel anchor SPA are convincing despite their
filigree design with high load-bearing capacities and
low thermal bridges (thermal optimized system). Vari-
ous combinations allow a wide range of applications for
connecting the load-bearing layer with the facing lay-
Facade technology
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Design software
PHILIPP provides a free software for the de-
sign of the sandwich panel anchor systems.
Here are some advantages of the software
available on the PHILIPP website: www.philipp-group.de
98 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Load-bearing anchors SPA-1 Load-bearing anchors SPA-2 Load bearing anchors CPC
see page 94
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 99
Sandwich panel anchor SPA
SPA load-bearing anchors with their product combinations of Load-bearing anchor SPA-1 / SPA-2
two types (SPA-1, SPA-2), four diameters and many heights cov-
Ref.-no. Ref.-no. Dimensions
er the widest range of applications. Insulation thicknesses up to SPA-1 SPA-2 Ød H L
40 cm are possible. Small cross sections reduce thermal bridges [mm] [mm] [mm]
to a minimum, high design resistances prove the efficiency of this 77SPA1050160 77SPA2050160 5.0 160 263
load-bearing anchor system. 77SPA1050180 77SPA2050180 5.0 180 303
77SPA1050200 77SPA2050200 5.0 200 343
PHILIPP GmbH
77SPA1050220 77SPA2050220 5.0 220 383
77SPA1050240 77SPA2050240 5.0 240 423
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Institut für
L
Werkstoffe im Bauwesen
Ød
77SPA1070180 77SPA2070180 6.5 180 299
77SPA1070200 77SPA2070200 6.5 200 338
77SPA1070220 77SPA2070220 6.5 220 378
0
108020
77SPA
Nr.:
Artikel
/ 200
- Ø8
SPA1
Typ:
L Institut für
Werkstoffe im Bauwesen
/ 200
- Ø8
SPA2
Typ:
PHILIPP Sandwich panel anchor system SPA For further details of the application and design of the Sandwich panel anchor SPA
please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1986
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-F-002-en - 04/18 - PDF
Installation Instruction
100 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Connector pin VN / VB / AN
Z – 21.8-1986
Ød
grid. These pins are available in three types, Connector pins (VN), Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
Connector stirrups (VB) and Clip-on pins (AN), and are always com- Ød
bined with a load-bearing anchor system. The stainless steel pins
available for each insulation layer thickness are provided in three H
H
diameters (Ø4, 5 and 6 mm) and are very easy to handle during
installation. H
Ød VB AN
Connector pin
H Ref.-no. Connector pin (type VN) Connector stirrup (type VB) Clip-on pin (type AN)
[mm] Ød = 4.0 Ød = 5.0 Ød = 6.0 Ød = 4.0 Ød = 5.0 Ød = 4.0 Ød = 5.0
77____160 160 VN40 - - VB40 - AN40 AN50
77____180 180 VN40 - - VB40 - AN40 AN50
77____200 200 VN40 VN50 - VB40 - AN40 AN50
77____220 220 VN40 VN50 - VB40 - AN40 AN50
77____240 240 VN40 VN50 - VB40 VB50 AN40 AN50
77____250 250 - - - VB40 VB50 AN40 AN50
77____260 260 VN40 VN50 - - - - -
77____280 280 VN40 VN50 - - VB50 AN40 AN50
77____300 300 VN40 VN50 - - VB50 AN40 AN50
77____320 320 - VN50 VN60 - VB50 - AN50
77____340 340 - VN50 VN60 - - - AN50
77____360 360 - - VN60 - - - AN50
77____380 380 - - VN60 - - - AN50
77____400 400 - - VN60 - - - -
77____420 420 - - VN60 - - - -
77____440 440 - - VN60 - - - -
77____460 460 - - VN60 - - - -
77____480 480 - - VN60 - - - -
77____500 500 - - VN60 - - - -
77____520 520 - - VN60 - - - -
The reference number has to be added by the required pin type and diameter.
E.g. connector pin type VN; pin diameter Ød = 5.0 mm 50; height H = 280 mm Ref.-No.: 77VN50280
PHILIPP Sandwich panel anchor system SPA For further details of the application and design of the Sandwich panel anchor SPA
please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 21.8-1986
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-F-002-en - 04/18 - PDF
Installation Instruction
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 101
FT Anchor
Even the simple and efficient fixing of window and door
elements is also a challenge for reinforced precast con-
crete sandwich elements. Ideally, these elements should
be located in the insulation layer in order to benefit from
building physics advantages. The FT Anchor for doors,
Facade technology
Design software
For the planning of FT Anchors in reinforced concrete sandwich elements the free-of-charge PHILIPP design
software can be taken. Besides the actual design of load-bearing anchors and pins the use of FT Anchors can be
specified for each opening by a few clicks.
E xact U-value calculation enables www.philipp-group.de
thermal optimisation of single pan-
els or entire façades - here all ther-
mal losses via anchors and joints are
considered.
102 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 103
FT Anchor
FT Anchor
The window and door anchor (FT Anchor) enables a quick fixa-
tion of opening elements in reinforced precast concrete sandwich
panels or insulated double walls by its simple angle design and its
glass fibre reinforced plastic compound. By means of self-drilling
screws windows and doors are installed directly in the insulation
h
level and without thermal bridges. As the FT Anchor is already in-
stalled during the production of the sandwich panel or insulated
double wall, this results in a noticeable time advantage at the con-
struction site.
b l
FT Anchor
Ref.-no. Dimensions
b l h
[mm] [mm] [mm]
77FTA060 60 100 73
77FTA080 80 100 73
77FTA120 120 140 73
PHILIPP FT Anchor
Picture 1
For further details of the application and design of the FT Anchor please refer to our
77FTA080 80 100 73
PHILIPP FT Anchor
website www.philipp-group.de.
b b > 120 mm
Picture 2 Picture 3
www.philipp-group.de
Installation Instruction
104 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 105
Fixing sockets with our promise: stronger than the concrete
Fixations are as important as connections in prefabricated concrete elements. Because often elements have
to be fixed directly to prefabricated concrete panels, slabs or beams, and this should be done very fast and
simple to minimise mounting costs. Prefabricated fixing points with high load-bearing capacities offer ideal
conditions for this in comparison to retrofitted solutions.
Fixing technology
106 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Fixing technology
Fixing sockets Page 108
Corner guards Page 112
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 107
Fixing sockets
Fixing sockets are available in four different designs
and thus open up numerous possibilities for fixing ele-
ments of all kinds to precast concrete parts, regardless of
whether on the face or surface side. These fixing points
already integrated in the precast concrete element save
time during installation compared to e.g. dowel-solutions
Fixing technology
108 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Cross pin and nailing plate Cross hole and nailing plate Waved end and nailing plate Angular end and nailing plate
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 109
Fixing sockets
PHILIPP Fixing sockets For further details of the application and design of the Fixing sockets please refer to
our website www.philipp-group.de.
VB3-B-001-en - 01/16
110 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Fixing socket with waved end / angular end
PHILIPP Fixing sockets For further details of the application and design of the Fixing sockets please refer to
our website www.philipp-group.de.
VB3-B-001-en - 01/16
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 111
Corner guards
Corner guards are installed to protect edges of precast
reinforced concrete elements, e.g. columns or walls. Both
the angle geometry itself, the material and the anchoring
elements in the prefabricated part are available in vari-
ous designs, so that numerous combinations are possible
and therefore leave hardly any wishes unfulfilled.
Fixing technology
112 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
FV - hot-dip galvanised
82KSW 1 A 050 1500 FV A4 - stainless steel SS316
A2 - stainless steel SS304
Reinforcement
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 113
Corner guard
Corner guard type 1A Corner guard type 2A Corner guard type 3A /2A /3A
Ref.-no. Angle L Ref.-no. Angle L Ref.-no. Angle L
type 1 [mm] type 2 [mm] type 3 [mm]
82KSW1A0501000__ 1000 82KSW2A0501000__ 1000 82KSW3A0501000__ 1000
82KSW1A0501500__ 50×5 1500 82KSW2A0501500__ 50×5 1500 82KSW3A0501500__ 53×5 1500
82KSW1A0502000__ 2000 82KSW2A0502000__ 2000 82KSW3A0502000__ 2000
82KSW1A0601000__ 1000 82KSW2A0601000__ 1000 82KSW3A0601000__ 1000
82KSW1A0601500__ 60×6 1500 82KSW2A0601500__ 60×6 1500 82KSW3A0601500__ 64×6 1500
82KSW1A0602000__ 2000 82KSW2A0602000__ 2000 82KSW3A0602000__ 2000
82KSW1A0801000__ 1000 82KSW2A0801000__ 1000 82KSW3A0801000__ 1000
82KSW1A0801500__ 80×6 1500 82KSW2A0801500__ 80×8 1500 82KSW3A0801500__ 84×6 1500
82KSW1A0802000__ 2000 82KSW2A0802000__ 2000 82KSW3A0802000__ 2000
82KSW1A1001000__ 1000 82KSW2A1001000__ 1000 82KSW3A1001000__ 1000
82KSW1A1001500__ 100×8 1500 82KSW2A1001500__ 100×8 1500 82KSW3A1001500__ 110×8 1500
82KSW1A1002000__ 2000 82KSW2A1002000__ 2000 82KSW3A1002000__ 2000
PHILIPP Corner guard For further details of the application and design of the Corner guard please refer to
our website www.philipp-group.de.
VB3-B-006-en - 08/18
www.philipp-group.de
Data sheet
114 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Corner guard type 1B / 2B / 3B
PHILIPP Corner guard For further details of the application and design of the Corner guard please refer to
our website www.philipp-group.de.
VB3-B-006-en - 08/18
www.philipp-group.de
Data sheet
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 115
Corner guard
PHILIPP Corner guard For further details of the application and design of the Corner guard please refer to
our website www.philipp-group.de.
VB3-B-006-en - 08/18
www.philipp-group.de
Data sheet
116 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 117
If you don’t want to hear anything, please read
Requirements from buildings physics are also becoming more and more important in the prefabricated build-
ing technology. Here, the protection of human health but also rising demands on comfort are playing an
increasingly important role.
Sound insulation takes up a considerable part here, so that unacceptable disturbances due to sound transmis-
sion are avoided. In addition to air-borne sound insulation, impact sound insulation is an important component
when considering the structural physics of a building.
In storey buildings, stair flights and landings must be installed soundproofed so that impact sound trans-
mission from the staircase via the staircase walls or floor slabs is prevented. In case of precast reinforced
concrete elements, suitable decoupling elements can meet this requirement.
The secret of sound insulation lies in the actual elastomer bearings, which are the most important part of the
bearings.
Noise reduction technology
118 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 119
Noise reduction technology
Bearing casing
Plastic bushing
Steel plate
Elastomeric bearing
120 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Compact anchor Threaded anchor (wavy tail) Threaded anchor (straight tail) Threaded anchor (angled)
The Bearing system with noise reduction and fire protection is also available in stainless steel.
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 121
Bearing system with noise reduction
Bearing element
b Ref.-no. t h hA Elastomeric bearing Steel plate
[mm] [mm] [mm] [mm]
Galvanised version
h
67TSEN-CIP Cipremont® Bright zinc hA
132 88 76 45
67TSEN Compression bearing plated
Stainless steel version
67TSENVA-CIP Cipremont® Stainless b
132 88 76 45 t
67TSENVA Compression bearing steel
Threaded bolt
Ref.-no.
Thread e LB
M [mm] [mm]
S355 galvanised (marking ST) M
670TSSN160ST 160
670TSSN170ST 170 e
670TSSN180ST 180
670TSSN190ST M36 60 190 ST LB
670TSSN200ST 200
670TSSN210ST 210
670TSSN220ST 220
Tempered steel (marking 8)
670TSSN1608 160
670TSSN1708 170
670TSSN1808 180
670TSSN1908 M36 60 190 8
670TSSN2008 200
670TSSN2108 210
670TSSN2208 220
Stainless steel S460 (marking VA)
670TSSN160VA 160
670TSSN170VA 170
670TSSN180VA 180
670TSSN190VA M36 60 190 VA
670TSSN200VA 200
670TSSN210VA 210
670TSSN220VA 220
PHILIPP Bearing system with noise reduction For further details of the application and design of the Bearing system with noise
reduction and fire protection please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 15.7-332
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-S-001-en - 02/19 - PDF
Installation Instruction
122 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Threaded anchors
Compact anchor
Ref.-no. Thread ØD1 L Øds
[mm] [mm] [mm]
Galvanised version
67TSS360235 RD 36 60 235 25 Øds
Stainless steel version
L
75TSS360235VA RD 36 60 235 25
ØD1
PHILIPP Bearing system with noise reduction For further details of the application and design of the Bearing system with noise
reduction and fire protection please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 15.7-332
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-S-001-en - 02/19 - PDF
Installation Instruction
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 123
Bearing system with noise reduction
67T
kel
Nr.:
Typ
150 SBM
:
kg/m N02
³ 0
20
PHILIPP Bearing system with noise reduction For further details of the application and design of the Bearing system with noise
reduction and fire protection please refer to our website www.philipp-group.de.
PHILIPP GmbH
Lilienthalstrasse 7-9
63741 Aschaffenburg
Tel . +49 (0) 6021 / 40 27-0
Fax +49 (0) 6021 / 40 27-440
Z – 15.7-332
Institut für
Werkstoffe im Bauwesen
Technische Universität
Darmstadt
VB3-S-001-en - 02/19 - PDF
Installation Instruction
124 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 125
Wide range of earthing technology
Earthing technology is always used when a defined reference potential or potential equalisation shall to be
provided. This is to short-circuit any voltages that may occur. In principle, measures are taken which are nec-
essary for the connection of an electrical part to earth.
Earthing technology
126 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Earthing technology
Earthing technology Page 128
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 127
Earthing technology for traffic sector
Earthing measures applied in the area of electrically op-
erated railways belong to the group of railway earthing.
With these special products, the reinforcement of pre-
cast reinforced concrete elements in the neighbourhood
Earthing technology
Earthing sleeves
Type Version Product DB ÖBB
01
Earthing sleeve 01
straight flat steel
F40 02
Flat steel double-sided Earthing sleeve 02 Ebs 15.03.19-11 ED 6409 Bl.5
40 mm × 5 mm straight flat steel 03
03
Earthing sleeve
90° angled flat steel
01
Earthing sleeve 01
straight rebar
71 EB B16
02 02
Earthing sleeve Reinforcement
double-sided Earthing sleeve Ebs 15.03.19-25 -
bar
straight rebar 03
Ø16 mm
03
Earthing sleeve
90° angled reinforcement bar
01
Earthing sleeve 01
K95 welding bridge
Copper cable 02 02 Ebs 15.03.19-26 -
95 mm2 double-sided Earthing sleeve 03
03
double sided welding bridge
German Railway, Austrian Railway
128 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Earthing connectors
Type Version Product DB
01
PVC cable coating Ebs 15/03/2017-1
double-sided cable lug
K50
Copper cable 50 mm2
02
Non-halogen cable coating Ebs 15/03/2017-1
double-sided cable lug
01
71 EV
PVC cable coating Ebs 15/03/2017-1
Earthing connector
double-sided cable lug
K70
Copper cable 70 mm2
02
Non-halogen cable coating Ebs 15/03/2017-1
double-sided cable lug
03
K70
VPE cable coating Ebs 15/03/2017-6
CuStAl cable 70 mm2
double-sided cable lug
German Railway
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 129
Earthing technology for traffic sector
LH
F40.02
B L
M F40.03
LH
PHILIPP Earthing technique in traffic sector For further details of the application and design of Earthing sleeves please refer to
our website www.philipp-group.de.
Product Overview
130 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Earthing sleeve type 71 EB B16
Contrary to the Earthing sleeve with flat steel, the type 71 EB B16
has a reinforcing bar Ø16 as conductor. With this type the socket
B16.01
is crimped on the rebar. The threaded insert consists of a steel
socket with a welded stainless steel washer. With a copper layer, B16.02
which in addition to its good conductivity also serves as additional L
corrosion protection, the threaded socket is provided.
LH
L
M
LH B16.03
L
M
LH
B
PHILIPP Earthing technique in traffic sector For further details of the application and design of Earthing sleeves please refer to
our website www.philipp-group.de.
Product Overview
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 131
Earthing technology for traffic sector
This Earthing sleeve has a flexible copper cable with a cross sec-
tion of 95 mm² as a conductor. It is available with a crimped-on
threaded insert as well as with a crimped-on welding bridge for K95.01
LS
welding to the reinforcement. Here, the welding bridge is made
K95.02
by pressing a special steel tube. Both, the threaded insert and the L
welding bridge are coated with a copper layer to improve the con-
LH
ductivity and to protect them against corrosion. LH
M L
LH
M LS
LS K95.03
PHILIPP Earthing technique in traffic sector For further details of the application and design of Earthing sleeves please refer to
our website www.philipp-group.de.
Product Overview
132 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
Earthing connector type 71 EV K50
PHILIPP Earthing technique in traffic sector For further details of the application and design of Earthing connectors please refer
to our website www.philipp-group.de.
Product Overview
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 133
Earthing technology for traffic sector
PHILIPP Earthing technique in traffic sector For further details of the application and design of Earthing sleeves please refer to
our website www.philipp-group.de.
Product Overview
134 © 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019
PHILIPPGROUP
© 2019 PHILIPP GmbH, 63741 Aschaffenburg • Technical changes and errors reserved • November 2019 135
PHILIPPGROUP
Imprint
PHILIPP GmbH
Lilienthalstrasse 7-9
D-63741 Aschaffenburg
Managing Director:
Martin Philipp
Thorsten Philipp
Responsible:
Thorsten Philipp
Companies Register:
Amtsgericht Aschaffenburg
HRB-No.:
896
Ust-IdNo.:
DE 132084295
Our customers trust us to deliver. We do everything in our power to reward their faith
and we start each day intending to do better than the last. We provide strength and
stability in an ever-changing world.
Sustainable
solutions
PHILIPPGROUP
PHILIPP GmbH PHILIPP GmbH PHILIPP GmbH PHILIPP ACON Hydraulic GmbH PHILIPP Vertriebs GmbH
Lilienthalstrasse 7-9 Roßlauer Strasse 70 Sperberweg 37 Hinter dem grünen Jäger 3 Leogangerstraße 21
D-63741 Aschaffenburg D-06869 Coswig/Anhalt D-41468 Neuss D-38836 Dardesheim A-5760 Saalfelden / Salzburg
Phone: + 49 (0) 6021 / 40 27-0 Phone: + 49 (0) 34903 / 6 94-0 Phone: + 49 (0) 2131 / 3 59 18-0 Phone: + 49 (0) 39422 / 95 68-0 Phone + 43 (0) 6582 / 7 04 01
Fax: + 49 (0) 6021 / 40 27-440 Fax: + 49 (0) 34903 / 6 94-20 Fax: + 49 (0) 2131 / 3 59 18-10 Fax: + 49 (0) 39422 / 95 68-29 Fax + 43 (0) 6582 / 7 04 01 20
[email protected] [email protected] [email protected] [email protected] [email protected]