0% found this document useful (0 votes)
41 views

Report Utility Juli

This document provides a utility report for PT. Wilmar Cahaya Indonesia Tbk-Ptk with energy and water usage data for various production areas. It shows electricity consumption in kilowatt-hours from the PLN grid and generators for today and month-to-date. Fuel consumption for generators, air compressor usage in cubic meters, steam production in metric tons from boilers, and raw water usage are also reported for key production processes. Total electricity consumption was 68,727 kWh for today and 128,000 kWh month-to-date.

Uploaded by

Saut Eduard
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views

Report Utility Juli

This document provides a utility report for PT. Wilmar Cahaya Indonesia Tbk-Ptk with energy and water usage data for various production areas. It shows electricity consumption in kilowatt-hours from the PLN grid and generators for today and month-to-date. Fuel consumption for generators, air compressor usage in cubic meters, steam production in metric tons from boilers, and raw water usage are also reported for key production processes. Total electricity consumption was 68,727 kWh for today and 128,000 kWh month-to-date.

Uploaded by

Saut Eduard
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

PT. Wilmar Cahaya Indonesia Tbk.

-Ptk
Utility Report
Report Date : 3-Jul-2019
Production Date : 2-Jul-2019
TODAY MONTH TO DATE
PLN ( Kwh) Unit (KWH) Unit (kwh)
PALM KERNEL CRUSHING 38,370 66,530
BOILER 2,455 4,670
###
TANK FARM 730 1,340
RAW WATER WTP 318 585
###
RAW WATER GENERAL 138 289
OFFICE 321 633
PENERANGAN 250 490
RO 353 819
###
COOLING TOWER 0
Refinery 4954 9,956
Fractionation 5,344 10,476
WORKSHOP 60 140
LAB 239 477
COMPRESOR 6,000 11,900
###
EFFLUENT TREATMENT 500 1,000
Pillow Pack 267 507
Ware House 250 530
ICM Solvent Extraction 2,070 6,320
NETRALIS/ACID 800 1,400
Dry Bleaching Plant ( NBIO) 600 1,300
ILLIPE CRUSHING 4,708 8,638
Used Total PLN 68,727 128,000
TURBIN (KWH)
PALM KERNEL 0
BOILER 0
TANK FARM 0
RAW WATER WTP 0
RAW WATER GENERAL 0
OFFICE 0
PENERANGAN 0
RO 0
COOLING TOWER 0
Refinery 0
Fractionation 0
WORKSHOP 0
LAB 0
COMPRESOR 0
EFFLUENT TREATMENT 0
Pillow Pack 0
Ware House 0
ILLIPS CRUSHING 0
Used Total Turbin 0 0
Genset (KWH)
PALM KERNEL 0
BOILER 0
TANK FARM 0
RAW WATER WTP 0
RAW WATER GENERAL 0
OFFICE 0
PENERANGAN 0
RO 0
COOLING TOWER 0
Refinery 0
Fractionation 0
WORKSHOP 0
LAB 0
COMPRESOR 0
EFFLUENT TREATMENT 0
Pillow Pack 0
Ware House 0
ILLIPS CRUSHING 0
Used Total Genset 0 0
Total Power Consumtion 68,727 128,000

FUEL CONS. FOR GENSET Consumtion (Ltr) Consumtion (Ltr)


SOLAR ###
0

AIR COMPRESOR (NM3) Unit (NM3) Unit (NM3)


Header FM 37254.6799999999
Crushing PK 19,116 35,192
Refinery 2,500 5,000
Fractionation 14,094 35,422
Boiler 2,500 5,000
###
Turbin 0
Tank farm 0
Pillow pack 350 750
Crushing Illips Nuts 1,500 3,000
ICM Solvent Extraction 800 2,300
Used Total 40,860 86,664
Loss 15,510 21,417
BOILER Unit (MT) Unit (MT)
Steam Refinery 55,417 109,322
Steam Fractionation 36,595 69,755
Steam TANK FARM 30,240 56,763
Steam Turbin ###
0
Steam DEAERATOR 41,089 83,320
###
Steam Crushing Illips Nuts 45,000
Steam ICM Solvent Extraction 30,000 75,000
Steam NETRALIS/ACID 45,000 45,000
Steam Dry Bleaching Plant ( NBIO) 10,000 15,000
Steam Loss 3,000 6,000
Used Total 251,341 505,160
Steam Produksi Boiler 300,000 608,100
Diff -48,659 -102,940

TOTAL RAW WATER USED 1,032,000 2,015,000


A. OTHERS 382000
Society 150,000 318,000
Dirty cooling tower ( Refinery) 85,000 180,000
General 147,000 297,000
B. WATER TREATMENT PLANT Unit (ltr) Unit (Ltr)
RAW WATER 650,000 1,220,000
601,000 1,115,000
49,000 105,000
WTP Produce 650,000 1,220,000
RO 295,000 647,000
Refinery 40,000 80,000
Office ( Domestic) 20,000 30,000
PK Crushing 15,000 25,000
CT Turbin 0
Pillow Pack 500 1,000
Crushing Illips Nuts 40,000 40,000
ICM Solvent Extraction 90,000 170,000
NETRALIS/ACID 135,000 203,000
Dry Bleaching Plant ( NBIO) 0
Water Used 635,500 1,196,000
Loss 14500 24000
###
RO PROCESS ( DEMINT PLANT) Unit (ltr) Unit (Ltr)
WTP Used 295,000 647,000
Water Produce 245,000 531,000
###
Concentrate 50,000 116,000
Boiler 185,000 400,000
###
Fractionation & Chiller 60,000 131,000
PK Crushing - 0

FUEL CONS. FOR BOILER Tonase (MT) Tonase (MT)


SHELL (Coal Boiler) 52,000 100,000
FIBRE (Coal Boiler) 10,000
Fuel Ratio 52000 ###
105,000
Remarks
PREPARED BY Approved by

Admin Utility Head Utility

You might also like