Fuel Cost Saving Calculation
Hoval (THSD) Competitor
Boiler Efficiency with Economizer 94.00 % 85.00 % Capacity 2,000.00 kg/h 2,000.00 kg/h Cold Water Temp 25.00 °C 25.00 °C Pressure 12.00 Bar 12.00 Bar Energy Required to Create Steam (feed water at 25°C and 12 bar) each hour 1,670,627.93 Kcal 1,670,627.93 Kcal Energy Input From Burner Required each hour 1,777,263.75 KCal 1,965,444.62 KCal
Annual Energy Input Required 5,189,610,162.68 KCal 5,739,098,297.56 KCal
Natural Gas Calorific Value 9,000.00 KCal/Nm³ 9,000.00 KCal/Nm³ Annual Fuel Consumption 576,623.35 Nm³ 637,677.59 Nm³ LNG Price per Nm3 6,000.00 Rp 6,000.00 Rp
Annual Operational Cost 3,459,740,108 Rp 3,826,065,532 Rp
Annual Operational Saving if Using Hoval THSD Boiler compared to Competitor Rp 366,325,423.25 a year
Operational Saving for 20 years Boiler Lifetime Rp 7,326,508,464.97