ELXC SERIES ITEM NO.

_______________
MODEL “ELXC”
HIGH EFFICIENCY EXTRACTOR VENTILATOR
WITH CLEAN-IN-PLACE TECHNOLOGY

GENERAL SPECIFICATIONS AND DESCRIPTION


Furnish Gaylord Ventilator Model “ELXC-___________” as shown on plans
and in accordance with the following specifications:

HIGH EFFICIENCY EXTRACTION: Each ventilator shall contain“XGS”High


Efficiency Extractors utilizing the “capture and drain” principle. Extractor
efficiencies shall be determined using ASTM F2519-2005 testing procedures
as accepted by ASHRAE TC 5.10 and ASHRAE Standard 154-2011 - 4.7.2.
The “capture and drain” principle shall prevent water from entering the
plenum and duct areas during “FAN ON” wash cycles, thus providing 24/7
operators the full effect of clean-in-place technology. The High Efficiency
Extractors shall not exceed 55 db, on typical cooking lines, as measured
at the chef’s ear so fatigue is minimized and productivity is optimized.

CAPTURE AND CONTAINMENT: Each ventilator shall achieve capture


and containment using the lowest possible airflow rates through “passive”
versus“active”design features, thus eliminating the wiring or adjustment of
internal motors, plenums or jets. The ventilator shall include an integrated
capture wall to achieve its airflow rates. The lowest possible airflow rates
shall be tested to ASTM 1704-09 by the Food Service Technology Center APPLICATION
and published on their website for easy confirmation. Wall mounted canopy for use over all types of equipment; ovens, broilers,
griddles, fryers, ranges, steam equipment, etc.
http://www.fishnick.com/publications/appliancereports/hoods/
DESIGN FEATURES
CLEAN-IN-PLACE WASH TECHNOLOGY: Each ventilator shall include
two full length stainless steel wash manifolds with brass nozzles; one to • Internal Canopy Radius
power wash the inlet face and internal passages of the extractors during • Enhanced “XGS” Extractor Angle and Slot Spacing
“FAN ON” mode and one to wash the plenum chamber, during the “FAN • Faceted “Super Capture”™ Lip
OFF” mode as programmed by the Gaylord Command Center. Each • Integrated Capture Wall
wash manifold on each ventilator section shall operate independently so
wash cycles may be programmed at different frequencies and different
durations to reduce water and detergent usage and optimize cleaning OPTIONAL EQUIPMENT
efficacy according to load and demand. Each ventilator section shall drain 1. Decorative Facings and Trim
to sloping gutters with 2” outlets. 2. Demand Control Ventilation
CONSTRUCTION: Each ventilator shall include full length access panels that 3. Fire Extinguishing Systems
are non-tool entry, non-gasketed and non-removable to ease inspection of 4. Pollution Control Systems
extractors, plenum and fire extinguishing system. The ventilator shall be 5. Utility Distribution Systems
of all stainless steel construction, not less than 18 gauge, type 300 series.
6. “XGS” Spark Arrestor Extractors
All exposed surfaces shall be a number 4 finish. The use of aluminized
steel or galvanized steel is not acceptable. The Ventilator shall include a
static pressure port in each section to be used in balancing exhaust air
volumes. Continuous front and rear mounting brackets shall be provided
to facilitate mounting to the wall and hanging from the overhead building
structure. Each duct collar shall include as standard a Gaylord Balancing
Damper (GBD) with opposed blades that adjust manually through access
from within the canopy. Ventilators built in end-to-end multiple sections
shall have as standard “Continuous Capture” from one end to the other to
ease cleaning and improve capture and containment.

LIGHT FIXTURES: The ventilator shall be equipped with:


o Recessed LED 6 Watts/Ft. Min.
o Recessed fluorescent 12 Watts/Ft. Min.
o100 watt surface mounted incandescent 24 Watts/Ft. Min.
o150 watt recessed incandescent 36 Watts/Ft. Min.

Light fixtures shall be factory pre-wired to a single connection point.


Ventilators built in multiple sections shall be furnished with coiled flex
conduit for interconnecting sections.

ACCEPTANCE & APPROVALS: Each ventilator shall include an integral


“Autostart”controller and sensors to meet current IMC standards (optional
outside North America). Each ventilator shall include a built-in 1” air space
at the rear that is Listed for reduced clearance to combustibles, and is NFPA-
96 and IMC compliant when mounting against a combustible wall. Each
ventilator shall be Listed to UL Standard 710, ETL Sanitation, comply with
all requirements of NFPA-96, IMC, UMC, BOCA, and SBCCI mechanical codes GAYLORD INDUSTRIES
and be capture tested to ASTM 1704-09 with High Efficiency Extractors 10900 SW AVERY ST • TUALATIN, OREGON 97062 U.S.A.
tested to ASTM 2519-2005. PHONE: 800.547.9696 • FAX: 503.692.6048 • email: [email protected]
www.gaylordusa.com
ELXC SERIES
30” STANDARD
ALSO AVAILABLE 24” HIGH,
OR WITH A 12” FRONT

48” MINIMUM. *16’ -0” MAX. UNIT LENGTH.


DIMENSION VARIES FOR GREATER LENGTH, JOIN TWO OR MORE
WITH DEPTH OF THE SECTIONS TOGETHER. ALLOW 6” MIN.
EQUIPMENT. OVERHANG AT EACH END. IF CHARBROILER
IS AT END, OVERHANG 12”

“AUTOSTART” SENSOR
LIGHT FIXTURE

10”
OR 12” GAYLORD BALANCING DAMPER (LISTED)
HOT WATER INLET
CONTINUOUS 1” MINIMUM AIR SPACE
HANGING BRACKET (LISTED FOR REDUCED CLEARANCE
TO COMBUSTIBLES)
“XGS” SUPER HIGH EFFICIENCY
FILTRATION EXTRACTOR

PLENUM WASH MANIFOLD


EXTRACTOR WASH MANIFOLD

SUPERCAPTURE™ LIP CAPTURE WALL

NOTE: 18” OVERHANG OPTIONAL SIDE PANELS MAY BE


REQUIRED OVER 12” USED TO ENHANCE CAPTURE
UPRIGHT BROILER MIN. PERFORMANCE

6’-8”
MTG. HT.
DRAIN

ENGINEERING DATA
Mechanical Requirements Ventilator Lengths
The amount of exhaust volume required is dependent upon the type of cooking Maximum unit length 16’-0”. For greater lengths, join two or more sections together.
equipment and the type and volume of cooking. Contact factory for exhaust Check to ensure that there is adequate access into building and kitchen area.
volumes, duct sizes, and static pressures.
* Note: Ventilators manufactured outside North America; maximum unit length
Electrical 10’-0”.
Provide 120 volt 50/60Hz circuit to lights, 220/240 volt optional. Hanging Weight
Refer to Wash Control Cabinet for its electrical requirements.
Ventilator Width 48” 54” 60”
Ventilator Wt. / Lineal Ft. Lbs. 85 90 95
The manufacturer reserves the right to modify the materials and specifications resulting